Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Quant Imaging Med Surg ; 13(1): 352-369, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36620171

RESUMO

Background: The infrapatellar fat pad (IPFP) plays an important role in the incidence of knee osteoarthritis (OA). Magnetic resonance (MR) signal heterogeneity of the IPFP is related to pathologic changes. In this study, we aimed to investigate whether the IPFP radiomic features have predictive value for incident radiographic knee OA (iROA) 1 year prior to iROA diagnosis. Methods: Data used in this work were obtained from the osteoarthritis initiative (OAI). In this study, iROA was defined as a knee with a baseline Kellgren-Lawrence grade (KLG) of 0 or 1 that further progressed to KLG ≥2 during the follow-up visit. Intermediate-weighted turbo spin-echo knee MR images at the time of iROA diagnosis and 1 year prior were obtained. Five clinical characteristics-age, sex, body mass index, knee injury history, and knee surgery history-were obtained. A total of 604 knees were selected and matched (302 cases and 302 controls). A U-Net segmentation model was independently trained to automatically segment the IPFP. The prediction models were established in the training set (60%). Three main models were generated using (I) clinical characteristics; (II) radiomic features; (III) combined (clinical plus radiomic) features. Model performance was evaluated in an independent testing set (remaining 40%) using the area under the curve (AUC). Two secondary models were also generated using Hoffa-synovitis scores and clinical characteristics. Results: The comparison between the automated and manual segmentations of the IPFP achieved a Dice coefficient of 0.900 (95% CI: 0.891-0.908), which was comparable to that of experienced radiologists. The radiomic features model and the combined model yielded superior AUCs of 0.700 (95% CI: 0.630-0.763) and 0.702 (95% CI: 0.635-0.763), respectively. The DeLong test found no statistically significant difference between the receiver operating curves of the radiomic and combined models (P=0.831); however, both models outperformed the clinical model (P=0.014 and 0.004, respectively). Conclusions: Our results demonstrated that radiomic features of the IPFP are predictive of iROA 1 year prior to the diagnosis, suggesting that IPFP radiomic features can serve as an early quantitative prediction biomarker of iROA.

2.
Wound Repair Regen ; 28(6): 789-796, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32729128

RESUMO

Whether the depth and healing of scalds and contact burns are similar is controversial. Due to water's greater heat capacity, we hypothesized that when exposed to similar temperatures and durations of exposure, burns caused by hot water would be deeper than those caused by contact with hot metal. Forty standardized burns were created in two anesthetized female domestic pigs using a brass bar or circulating heated water. In one pig, the temperature was kept constant (95°C) while the duration of exposure varied (5, 10, 15 seconds) In the second pig, the exposure time was kept constant (10 seconds) while the temperature of exposure varied (70°C, 80°C, 98°C). Periodic punch biopsies were taken to determine burn depth immediately after injury, percentage burns reepithelialized within 21 days, and depth of scar at 28 days. The analysis was performed using analysis of variance. When the temperature was held constant, duration of exposure (5, 10, and 15 seconds) was associated with scar depth (2.1 vs 3.8 vs 5.0 mm, respectively, P = 0.001) but not with burn depth (2.0 vs 2.2 vs 2.3 mm, respectively, P = 0.10). When exposure duration was held constant, temperature (70°C, 80°C, 98°C) was associated with scar depth (0.6 vs 1.7 vs 3.6, P < 0.001) but not with burn depth (1.2 vs 1.5 vs 1.7 mm, respectively, P = 0.21). Burn depths were greater for scald than contact burns although not significantly greater. After controlling for temperature, the difference in scar depth between scalds and contact burns was statistically significant (marginal means 3.0 for contact burns, 4.3 for scalds, P = 0.008). We conclude that burns created in swine with circulating hot water result in deeper scars than those created by contact with a brass bar when controlling for temperature and duration of exposure.


Assuntos
Queimaduras/diagnóstico , Cicatriz/diagnóstico , Reepitelização/fisiologia , Pele/lesões , Cicatrização/fisiologia , Animais , Biópsia , Queimaduras/complicações , Cicatriz/etiologia , Modelos Animais de Doenças , Feminino , Temperatura Alta/efeitos adversos , Estudos Prospectivos , Pele/patologia , Suínos , Índices de Gravidade do Trauma
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA