1.
Phys Med ; 123: 103405, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38870645

RESUMO

The effect of mammography measurement conditions was investigated to evaluate their impact on measurement uncertainties in clinical practice. The most prominent physical X-ray beam quantities i.e., - air kerma, half-value layer, and X-ray tube voltage - were examined by measuring the response of two ionization chambers and six X-ray multimeters (XMMs) of different models. Measurements were performed using several anode/filter combinations and both with and without the compression paddle in the X-ray beam. Maximum differences of higher than 6 % were found for all quantities when the dosimeter displayed value was compared with the reference value or the variation within the clinical anode/filter combinations Mo/Mo and Mo/Rh were considered. The study showed that the calibration procedure with the W/Al anode/filter combination was reliable only for ionization chambers, and the response of XMMs varies in such a way that the calibration coefficient cannot be predicted between various measurement conditions used in calibration and clinical practices. XMM calibrations are typically performed without a compression paddle in the beam, and the response of the XMM changes when radiation quality is slightly altered. If XMM specific data is not available, based on this study, an additional uncertainty of 2 % (k = 1) could be used as a typical estimate, at least for air kerma measurements. XMMs should be used for clinical measurements in mammography only with correct settings. If the correct settings are not available, the XMMs should not be used or used only with extreme caution.


Assuntos
Mamografia , Mamografia/instrumentação , Calibragem , Incerteza , Radiometria/instrumentação , Dosímetros de Radiação
2.
Appl Radiat Isot ; 205: 111160, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38171076

RESUMO

Source strength measurements are of critical importance for brachytherapy and are often performed in hospitals using well-type chambers. Quality assurance and quality control procedures should be implemented, but that may prove difficult in some hospitals due to the lack of equipment or metrological support. A study was conducted to investigate the status of the measurement equipment in Serbian hospitals and to organize an intercomparison campaign using a hospital 192Ir source. All the hospitals were able to measure the source strength with the required accuracy, but the quality assurance can be improved. Two hospitals performed stability checks, which were evaluated. Uncertainty budget was created during the exercise and is presented in this paper. The described methodology can be used to quickly assess the performance of brachytherapy centers, and can be easily adapted to calibration procedure.


Assuntos
Braquiterapia , Braquiterapia/métodos , Sérvia , Dosagem Radioterapêutica , Controle de Qualidade , Calibragem , Radiometria/métodos , Radioisótopos de Irídio
3.
Radiat Prot Dosimetry ; 200(2): 155-163, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38011606

RESUMO

The European Association of National Metrology Institutes (EURAMET) within its research programme European Metrology Programme for Innovation and Research (EMPIR) funded project EMPIR 19NET03 supportBSS that contributes to the establishment of a European Metrology Network (EMN) for Radiation Protection (RP). The EMN-RP was established in September 2021 with the intent to work as a meeting point for the metrology community and all stakeholders in the field of ionising radiation regulation, thus providing quality assurance for measurements in each of the exposure situations contemplated in the European Legislation. Within project EMPIR 19NET03, work package 3 aims at the preparation of a Strategic Research Agenda (SRA) by identifying the metrology needs to support the European legislation and regulation in Radiation Protection and of two Roadmaps for metrology services, one under the European Council Directive 2013/59/EURATOM and the other under the EURATOM Treaty. Following a Gaps Workshop held in September 2020 and a second internal workshop that took place in April 2022, a questionnaire was prepared for distribution to the stakeholders, e.g. RP platforms and authorities, academia, industry, among other, together with an accompanying paper. In this paper, the authors present the state of the art of European legislation in RP, address the importance of metrology, the practices and activities that need metrology to meet the requirements set in the regulations, emphasise the need for quality assured measurements in all fields, highlight the stakeholders contributions in their specific area and show their vision of the EMN-RP.


Assuntos
Proteção Radiológica , União Europeia , Indústrias , Radiação Ionizante
4.
Radiat Prot Dosimetry ; 199(10): 1103-1109, 2023 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-37114847

RESUMO

The paper analyses the possibility of commercial neon indicator lamp at low pressure application as a gamma radiation detector. The diode is most often used as an indicator in electrical switchers. The analysis was performed on the basis of experimental electrical breakdown time delay data as a function of relaxation time, applied voltage and gamma ray air kerma rate. It has been shown that the indicator can be used as a detector for relaxation time greater than 70 ms. During this time period, a complete recombination/de-excitation of the particles formed during previous breakdown and subsequent self-sustaining discharge, which can further initiate next breakdown, takes place. It was also shown that gamma radiation leads to a significant reduction in electrical breakdown time delay for applied voltages close to indicator breakdown voltage. Based on the behavior of the dependence of the mean value of the electrical breakdown time delay on the gamma ray air kerma rate, it was shown that the indicator can be used very efficiently as a detector up to air kerma rate of $\textsf{2.3}\cdot \textsf{10}^{-\textsf{5}}$ Gy/h, when the electrical breakdown time delay is measured for applied voltage 10% higher than the breakdown voltage.


Assuntos
Raios gama , Dosímetros de Radiação
5.
Health Phys ; 113(4): 252-261, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28846586

RESUMO

Electronic personal dosimeters (EPDs) are increasingly being used alongside conventional thermoluminescent dosimeters to measure the dose of legal record in terms of personal dose equivalent. Therefore, it is of great importance to execute performance tests of these dosimeters in photon fields of various energies and at various angles of incidence. This testing is done in order to simulate the behavior of these dosimeters in realistic multidirectional polyenergetic ionizing radiation fields. Tests of accuracy, linearity, energy response, and angular response have been performed on 10 EPDs from multiple manufacturers. Various radiation qualities have been used in the energy range from 33 keV to 1.33 MeV and for angles of incidence 0° to 80°. This research proves that many of the EPDs tested performed according to the manufacturer's specifications and the requirements of the international standards regarding personal dosimetry.


Assuntos
Raios gama , Dosímetros de Radiação , Raios X , Humanos , Dosímetros de Radiação/normas , Exposição à Radiação/estatística & dados numéricos , Proteção Radiológica , Reprodutibilidade dos Testes
6.
Radiat Prot Dosimetry ; 162(1-2): 139-43, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25063785

RESUMO

The aim of this work was to investigate the different types of radiation detectors commonly used for radiation protection purposes as survey meters. The study was performed on survey meters that use different detectors as ionisation chamber, Geiger Mueller (GM) counter and scintillation detector. For each survey meter, energy dependence and angular response in X- and gamma-radiation fields was tested. The following commercially available survey meters were investigated: ionisation chambers Victoreen 451P, Babyline 31 and VA-J-15A, Geiger counter MRK-M87, 6150 AD6 and FAG FH 40F2 and scintillation counter 6150 ADB. As a source of gamma radiation, (137)Cs and (60)Co were used whereas X-ray radiation fields were generated using an X-ray unit. The radiation characteristics of the survey meters were mostly in compliance with references estimated by standard IEC 1017-2. However, some of them showed larger deviation at lower energies. GM counters exhibit strong energy dependence for low-energy photons.


Assuntos
Raios gama , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Radiometria , Desenho de Equipamento , Humanos , Fótons , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Contagem de Cintilação , Raios X