Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Front Oncol ; 14: 1360975, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38515567

RESUMO

Background: Neutrophil-to-lymphocyte ratio (NLR) is considered a potential prognostic marker in early breast cancer. However, the prognosis of absolute lymphocyte count (ALC) and NLR in metastatic breast cancer (MBC) has been reported in a few studies, and conclusions are still conflicting. This present manuscript aims to provide further solid evidence regarding the prognostic values of ALC and NLR in MBC patients. Method: Eligible studies that reported the associations between ALC or NLR and MBC were included by searching relative electronic databases. Overall survival (OS) and progression-free survival (PFS) were used as outcome measures. The hazard ratio (HR) values and 95% confidence interval (CI) of the outcome measures were collected as effect sizes, and further analysis and discussion were conducted according to the pooled HR, subgroup analysis, publication bias, and interstudy heterogeneity. Results: Twenty-nine studies comprising 3,973 patients with MBC were included. According to our findings, lower ALC was significantly associated with poorer prognosis of OS (HR = 0.57, 95% CI 0.48 to 0.68) and PFS (HR = 0.68, 95% CI 0.58 to 0.79), and greater NLR was associated with poorer OS (HR = 1.50, 95% CI 1.35 to 1.67) and PFS (HR = 1.82, 95% CI 1.42 to 2.35). Furthermore, the prognostic values of ALC and NLR in MBC were also observed in the subgroup analyses regarding cutoff values and ethnicities. Conclusion: Low ALC and elevated NLR were observed to be significantly associated with adverse OS and PFS in MBC, indicating that ALC and NLR may act as potential prognostic biomarkers of MBC patients. Meanwhile, our results will also provide some novel evidence and research clues for the selection and development of clinical treatment strategies for MBC patients. Systematic review registration: https://www.crd.york.ac.uk/PROSPERO/, identifier CRD42021224114.

2.
Adv Mater ; 36(23): e2400537, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38336365

RESUMO

Ionic liquid electrolytes (ILEs) are promising to develop high-safety and high-energy-density lithium-metal batteries (LMBs). Unfortunately, ILEs normally face the challenge of sluggish Li+ transport due to increased ions' clustering caused by Coulombic interactions. Here a type of anion-reinforced solvating ILEs (ASILEs) is discovered, which reduce ions' clustering by enhancing the anion-cation coordination and promoting more anions to enter the internal solvation sheath of Li+ to address this concern. The designed ASILEs, incorporating chlorinated hydrocarbons and two anions, bis(fluorosulfonyl) imide (FSI-) and bis(trifluoromethanesulfonyl) imide (TFSI-), aim to enhance Li+ transport ability, stabilize the interface of the high-nickel cathode material (LiNi0.8Co0.1Mn0.1O2, NCM811), and retain fire-retardant properties. With these ASILEs, the Li/NCM811 cell exhibits high initial specific capacity (203 mAh g-1 at 0.1 C), outstanding capacity retention (81.6% over 500 cycles at 1.0 C), and excellent average Coulombic efficiency (99.9% over 500 cycles at 1.0 C). Furthermore, an Ah-level Li/NCM811 pouch cell achieves a notable energy density of 386 Wh kg-1, indicating the practical feasibility of this electrolyte. This research offers a practical solution and fundamental guidance for the rational design of advanced ILEs, enabling the development of high-safety and high-energy-density LMBs.

3.
Talanta ; 202: 303-307, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31171186

RESUMO

In this study, we developed a new fluorescent probe (CMM) based on coumarin dye and malononitrile, for highly sensitive and selective detection of hypochlorite ion (ClO-). CMM showed a 45-fold fluorescence enhancement at 459 nm in the presence of ClO- and displayed an excellent selectivity over other competing species. The probe featured a fast response time (<15 s), which could be in favor of the real-time detection towards ClO-. Meanwhile, probe CMM could effectively monitor ClO- in physiological pH condition and the detection limit was estimated to be as low as 5.7 nM. Furthermore, its preeminent recognition properties made the successful application for monitoring ClO- in environmental water samples and labeling ClO- in living biological cells.


Assuntos
Cumarínicos/química , Corantes Fluorescentes/química , Ácido Hipocloroso/análise , Poluição Química da Água/análise , Linhagem Celular Tumoral , Cumarínicos/síntese química , Corantes Fluorescentes/síntese química , Humanos , Íons/análise , Estrutura Molecular , Imagem Óptica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA