Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Eur J Radiol Open ; 12: 100555, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38544918

RESUMO

Objective: To build a radiomics signature based on MRI images and evaluate its capability for preoperatively identifying the benign and malignant Soft tissue neoplasms (STTs). Materials and methods: 193 patients (99 malignant STTs and 94 benign STTs) were at random segmented into a training cohort (69 malignant STTs and 65 benign STTs) and a validation cohort (30 malignant STTs and 29 benign STTs) with a portion of 7:3. Radiomics features were extracted from T2 with fat saturation and T1 with fat saturation and gadolinium contrast images. Radiomics signature was developed by the least absolute shrinkage and selection operator (LASSO) logistic regression model. The receiver that operated characteristics curve (ROC) analysis was used to assess radiomics signature's prediction performance. Inner validation was performed on an autonomous cohort that contained 40 patients. Results: A radiomics was developed by a total of 16 radiomics features (5 original shape features and 11 were wavelet features) achieved favorable predictive efficacy. Malignant STTs showed higher radiomics score than benign STTs in both training cohort and validation cohort. A good prediction performance was shown by the radiomics signature in both training cohorts and validation cohorts. The training cohorts and validation cohorts had an area under curves (AUCs) of 0.885 and 0.841, respectively. Conclusions: A radiomics signature based on MRI images can be a trustworthy imaging biomarker for identification of the benign and malignant STTs, which could help guide treatment strategies.

2.
Genes Chromosomes Cancer ; 59(10): 595-600, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32447786

RESUMO

Recently, a novel group of spindle cell tumors defined by S100 and CD34 co-expression harboring recurrent fusions involving RET, RAF1, BRAF, and NTRK1/2 gene has been identified. Morphologically, they are characterized by monomorphic neoplasm cells, "patternless" growth pattern, stromal, and perivascular hyalinization, lacked necrosis. We reported a 52-year-old Chinese female patient with a S100 and CD34 co-expression sarcoma presenting in the right proximal forearm. The forearm mass initially emerged 19 months ago when it was misdiagnosed as a solitary fibrous tumor and was surgically removed without further treatment. Microscopically, the primary and the recurred tumors share the same features, resembling the morphology of the recently characterized group. Nevertheless, some distinct features, such as predominantly epithelioid tumor cells and focally staghorn vessels, were also present in our case. Genomic profiling with clinical next-generation sequencing was performed and revealed CDC42SE2-BRAF gene fusion, MET amplification, and CDKN2A/B deletion. Both FISH and nested RT-PCR were performed to confirm the gene fusion. The patient was treated with crizotinib for two cycles but showed no obvious benefit. The presented case adds to the spectrum of the novel, characterized solid tumors, and provides suggestions for emerging therapeutic strategies for precision medicine involving targeted kinase inhibitors.


Assuntos
Antígenos CD34/genética , Peptídeos e Proteínas de Sinalização Intracelular/genética , Proteínas de Membrana/genética , Proteínas de Fusão Oncogênica/genética , Proteínas Proto-Oncogênicas B-raf/genética , Proteínas S100/genética , Neoplasias de Tecidos Moles/genética , Antígenos CD34/metabolismo , Inibidor p16 de Quinase Dependente de Ciclina/genética , Feminino , Deleção de Genes , Dosagem de Genes , Humanos , Pessoa de Meia-Idade , Gradação de Tumores , Proteínas Proto-Oncogênicas c-met/genética , Proteínas S100/metabolismo , Neoplasias de Tecidos Moles/patologia
3.
PLoS One ; 14(4): e0215069, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30951550

RESUMO

PURPOSE: To investigate the value of dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) for evaluating denervated skeletal muscle in rabbits. MATERIALS AND METHODS: 24 male rabbits were randomly divided into an irreversible neurotmesis group and a control group. In the experimental group, the sciatic nerves of rabbits were transected for irreversible neurotmesis model. A sham operation was performed in the control group. MRI of rabbit lower legs was performed before nerve surgery and 1 day, 3 days, 5 days, 1 week, 2 weeks, 3 weeks, 4 weeks, 6 weeks, 8 weeks, 10 weeks, and 12 weeks after surgery. RESULTS: Signal intensity changes were seen in the left gastrocnemius muscle on the T2-weighted images. DCE-MRI derived parameters (Ktrans, Kep, and Vp) were measured in vivo. In the irreversible neurotmesis group, T2-weighted images showed increased signal intensity in the left gastrocnemius muscle. Ktrans, Vp values changes occur as early as 1 day after denervation, and increased gradually until 4 weeks after surgery. There are significant increases in both Ktrans and Vp values compared with those in the control group after surgery (P < 0.05). Kep values show no significant difference between the irreversible neurotmesis group and the control group. CONCLUSION: DCE-MRI hold the promise of an early and sensitive diagnosis of denervated skeletal muscle.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Denervação Muscular/métodos , Músculo Esquelético/inervação , Músculo Esquelético/patologia , Nervo Isquiático/lesões , Traumatismos do Sistema Nervoso/diagnóstico , Animais , Modelos Animais de Doenças , Aumento da Imagem , Processamento de Imagem Assistida por Computador/métodos , Masculino , Coelhos
4.
J Cancer Res Ther ; 12(2): 864-70, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27461665

RESUMO

OBJECTIVES: To evaluate the diagnostic potential of apparent diffusion coefficient (ADC) values of diffusion-weighted imaging (DWI) in distinguishing malignant and benign soft-tissue tumors. MATERIALS AND METHODS: Published studies were retrieved through comprehensive search in various computerized databases. High-quality studies relevant to ADC values of DWI in differential diagnosis of soft-tissue tumors were screened using our stringent inclusion and exclusion criteria for this meta-analysis. The standard mean difference with 95% confidence interval (95% CI) was estimated. Statistical analyses were performed using the STATA statistical software (Stata Co., College Station, TX, USA). RESULTS: Thirteen cohort studies were finally included, and these studies provided the required information on the diagnostic value of diffusion magnetic resonance imaging in soft-tissue tumors. The 13 studies contained a combined total of 344 malignant soft tumors and 315 benign soft tumors. The results of our meta-analysis revealed that mean ADC value in patients with malignant soft-tissue tumor decreased significantly in comparison with the ADC values obtained in patients with benign soft-tissue tumor (P < 0.001). Country-stratified analysis suggested that ADC value might play a predictive role in the differential diagnosis of soft-tissue tumors in China (P = 0.007), Egypt (P < 0.001), Germany (P = 0.001), Japan (P = 0.049), and The Netherlands (P < 0.001). CONCLUSION: Our results provide strong evidence that patients diagnosed with malignant soft-tissue tumors have low ADC values of DWI compared to those with benign soft-tissue tumors. Therefore, ADC measurements with DWI may be reliable in differential diagnosis of soft-tissue tumors.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias de Tecidos Moles/diagnóstico , Diagnóstico Diferencial , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Razão de Chances , Viés de Publicação
5.
Eur J Radiol ; 84(3): 450-457, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25544555

RESUMO

PURPOSE: The study was performed to evaluate magnetic resonance (MR) issues for the latest standard brands of plates and screws used in orthopedic surgery at a 1.5-T MR system, including the safety and metallic artifacts. METHODS: The plates and screws (made of titanium alloy and stainless steel materials, according to the latest standard brands) were assessed for displacement in degrees, MRI-related heating and artifacts at a 1.5-T MR system. The displacement in degrees of the plates and screws was evaluated on an angel-measurement instrument at the entrance of the MR scanner. The MRI-related heating was assessed on a swine leg fixed with a plate by using a "worst-case" pulse sequence. A rectangular water phantom was designed to evaluate metallic artifacts of a screw on different sequences (T1/T2-weighted FSE, STIR, T2-FSE fat saturation, GRE, DWI) and then artifacts were evaluated on T2-weighted FSE sequence by modifying the scanning parameters including field of view (FOV), echo train length (ETL) and bandwidth to identify the influence of parameters on metallic artifacts. 15 volunteers with internal vertebral fixation (titanium alloy materials) were scanned with MR using axial and sagittal T2-FSE, sagittal T2-FSE fat suppression and STIR with conventional and optimized parameters, respectively. Then all images were graded by two experienced radiologists having the experience of more than 7 years under double-blind studies that is neither of them knew which was conventional parameter group and optimized parameter group. RESULTS: The average deflection angle of titanium alloy and stainless steel implants were 4.3° and 7.7°, respectively, (less than 45°) which indicated that the magnetically induced force was less than the weight of the object. The deflection angle of the titanium alloy implants was less than the stainless steel one (t=9.69, P<0.001). The average temperature changes of titanium alloy before and after the scan was 0.48°C and stainless steel implants was 0.74°C, respectively, with the background temperature changes of 0.24°C. The water phantom test indicated that the DWI sequence produced largest artifacts, while FSE pulse sequence produced smallest artifacts. And T2-weighted FSE fat saturation sequence produced larger artifacts than STIR sequence. The influence of the scanning parameters on metallic artifacts was verified that metallic artifacts increased with longer echo train length and bigger FOV, while decreased with larger bandwidth. The interreader agreement was good or excellent for each set of images graded with Cohen's Kappa statistic. Image grading of axial and sagittal T2-FSE with optimized parameters were significantly superior to that with conventional parameters (grade, 3.3±0.5 vs 2.7±0.6, P=0.003; 3.2±0.4 vs 1.9±0.7, P=0.001) and image of STIR sequence received a better grade than T2-FSE FS sequence (grade, 3.4±0.5 vs 1.7±0.6, P<0.001). CONCLUSIONS: The latest standard plates and screws used in orthopedic surgery do not pose an additional hazard or risk to patients undergoing MR imaging at 1.5-T or less. Though artifacts caused by them cannot be ignored because of their relatively large size, it is possible to be minimized by choosing appropriate pulse sequences and optimizing scanning parameters, such as FSE and STIR sequence with large bandwidth, small FOV and appropriate echo train length.


Assuntos
Imageamento por Ressonância Magnética , Próteses e Implantes , Idoso , Ligas , Androsterona/análogos & derivados , Artefatos , Parafusos Ósseos , Método Duplo-Cego , Segurança de Equipamentos , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Metais , Pessoa de Meia-Idade , Imagens de Fantasmas , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA