Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
EuroIntervention ; 20(12): e770-e780, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38887883

RESUMO

BACKGROUND: Coronary access (CA) is a major concern in redo-transcatheter aortic valve implantation (TAVI) for failing supra-annular self-expanding transcatheter aortic valves (TAVs). AIMS: This ex vivo study evaluated the benefit of leaflet splitting (LS) on subsequent CA after redo-TAVI in anatomies deemed at high risk of unfeasible CA. METHODS: Ex vivo, patient-specific models were printed three-dimensionally. Index TAVI was performed using ACURATE neo2 or Evolut PRO (TAV-1) at the standard implant depth and with different degrees of commissural misalignment (CMA). Redo-TAVI was performed using the balloon-expandable SAPIEN 3 Ultra (TAV-2) at different implant depths with commissural alignment. Selective CA was attempted for each configuration before and after LS in a pulsatile flow simulator. The leaflet splay area was assessed on the bench. RESULTS: In matched comparisons of 128 coronary cannulations across 64 redo-TAVI configurations, the overall feasibility of CA significantly increased after LS (60.9% vs 18.7%; p<0.001). The effect of LS varied according to the sinotubular junction height, TAV-1 design, TAV-1 CMA, and TAV-2 implant depth, given TAV-2 alignment. LS enabled CA for up to CMA 45° with the ACURATE neo2 TAV-1 and up to CMA 30° with the Evolut PRO TAV-1. The combination of LS and a low TAV-2 implant provided the highest feasibility of CA after redo-TAVI. The leaflet splay area ranged from 25.60 mm2 to 37.86 mm2 depending on the TAV-1 platform and TAV-2 implant depth. CONCLUSIONS: In high-risk anatomies, LS significantly improves CA feasibility after redo-TAVI for degenerated supra-annular self-expanding platforms. Decisions on redo-TAVI feasibility should be carefully individualised, taking into account the expected benefit of LS on CA for each scenario.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/instrumentação , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Impressão Tridimensional , Estenose da Valva Aórtica/cirurgia , Vasos Coronários/cirurgia , Falha de Prótese , Reoperação
2.
Eur Heart J ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747246

RESUMO

BACKGROUND AND AIMS: Transcatheter aortic valve implantation (TAVI) has become the first choice to treat older patients with severe symptomatic aortic stenosis (AS). This study aimed to compare TAVI with surgery in low-risk patients ≤ 75 years of age, including both tricuspid and bicuspid AS. METHODS: The NOTION-2 trial enrolled and 1:1 randomized low-risk patients aged ≤ 75 years with severe symptomatic AS to TAVI or surgery. The primary endpoint was a composite of all-cause mortality, stroke or rehospitalization (related to the procedure, valve or heart failure) at 12 months. RESULTS: A total of 370 patients were enrolled with a mean age of 71.1 years and a median Society of Thoracic Surgeons risk score of 1.1%. A total of 100 patients had bicuspid AS. The 1-year incidence of the primary endpoint was 10.2% in the TAVI group and 7.1% in the surgery group (absolute risk difference 3.1%; 95% confidence interval [CI], -2.7% to 8.8%; hazard ratio (HR) 1.4, 95% CI: 0.7 to 2.9; p=0.3). Patients with TAVI, when compared to surgery, had lower risk of major bleeding and new-onset atrial fibrillation and higher risk of non-disabling stroke, permanent pacemaker implantation and moderate-or-greater paravalvular regurgitation. The risk of the primary composite endpoint was 8.7% and 8.3% in patients with tricuspid AS (HR 1.0, 95% CI: 0.5 to 2.3) and 14.3% and 3.9% in patients with bicuspid AS (HR 3.8, 95% CI: 0.8 to 18.5) treated with TAVI or surgery, respectively (P for interaction=0.1). CONCLUSIONS: Among low-risk patients aged ≤ 75 years with severe symptomatic AS, the rate of the composite of death, stroke, or rehospitalization at one year was similar between TAVI and surgery. TAVI outcomes in young bicuspid AS patients warrant caution and should be further investigated. (NOTION-2, ClinicalTrials.gov, NCT02825134).

3.
Cardiovasc Revasc Med ; 64: 7-14, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38448258

RESUMO

BACKGROUND: Left atrial appendage (LAA) occluder embolization is an infrequent but serious complication. OBJECTIVES: We aim to describe timing, management and clinical outcomes of device embolization in a multi-center registry. METHODS: Patient characteristics, imaging findings and procedure and follow-up data were collected retrospectively. Device embolizations were categorized according to 1) timing 2) management and 3) clinical outcomes. RESULTS: Sixty-seven centers contributed data. Device embolization occurred in 108 patients. In 70.4 % of cases, it happened within the first 24 h of the procedure. The device was purposefully left in the LA and the aorta in two (1.9 %) patients, an initial percutaneous retrieval was attempted in 81 (75.0 %) and surgery without prior percutaneous retrieval attempt was performed in 23 (21.3 %) patients. Two patients died before a retrieval attempt could be made. In 28/81 (34.6 %) patients with an initial percutaneous retrieval attempt a second, additional attempt was performed, which was associated with a high mortality (death in patients with one attempt: 2.9 % vs. second attempt: 21.4 %, p < 0.001). The primary outcome (bailout surgery, cardiogenic shock, stroke, TIA, and/or death) occurred in 47 (43.5 %) patients. Other major complications related to device embolization occurred in 21 (19.4 %) patients. CONCLUSIONS: The majority of device embolizations after LAA closure occurs early. A percutaneous approach is often the preferred method for a first rescue attempt. Major adverse event rates, including death, are high particularly if the first retrieval attempt was unsuccessful. CONDENSED ABSTRACT: This dedicated multicenter registry examined timing, management, and clinical outcome of device embolization. Early embolization (70.4 %) was most frequent. As a first rescue attempt, percutaneous retrieval was preferred in 75.0 %, followed by surgical removal (21.3 %). In patients with a second retrieval attempt a higher mortality (death first attempt: 2.9 % vs. death second attempt: 24.1 %, p < 0.001) was observed. Mortality (10.2 %) and the major complication rate after device embolization were high.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Remoção de Dispositivo , Sistema de Registros , Humanos , Masculino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Feminino , Idoso , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Tempo , Idoso de 80 Anos ou mais , Fatores de Risco , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Fibrilação Atrial/terapia , Fibrilação Atrial/mortalidade , Remoção de Dispositivo/efeitos adversos , Embolia/etiologia , Embolia/mortalidade , Pessoa de Meia-Idade , Dispositivo para Oclusão Septal , Oclusão do Apêndice Atrial Esquerdo
4.
Int J Cardiovasc Imaging ; 39(8): 1557-1559, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37149839

RESUMO

A higher incidence of conduction disturbances and permanent pacemaker implantation (PPI) has been observed after transcatheter aortic valve implantation (TAVI) in patients with bicuspid aortic valves (BAVs) as compared to those with tricuspid aortic valves (TAVs). This study aimed to provide an anatomical explanation for this observation, supported by an in-depth anatomical mapping of the membranous septum (MS) in a large cohort of BAVs and TAVs using cardiac computed tomography (CT). A total of 300 cardiac CT scans were analysed, revealing a significantly shorter sub-annular length of the MS in BAVs at all measuring points compared to TAVs (p < 0.001). In the current BAV cohort, the MS was found to be at its shortest at the RCC site, measuring less than 1 mm in depth. In addition, the MS was located more anteriorly towards the RCC in BAVs, where the transcatheter aortic valve tends to be implanted deeper, and we observed a trend towards a higher PPI rate in BAVs. Future studies should investigate whether anatomical mapping of the MS in patients undergoing TAVI could be a useful tool for decision-making and potentially mitigate the risk of conduction disturbances.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Carcinoma de Células Renais , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Neoplasias Renais , Substituição da Valva Aórtica Transcateter , Humanos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Valor Preditivo dos Testes , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
5.
EuroIntervention ; 19(1): 37-52, 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-36811935

RESUMO

Significant coronary artery disease (CAD) is a frequent finding in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI), and the management of these two conditions becomes of particular importance with the extension of the procedure to younger and lower-risk patients. Yet, the preprocedural diagnostic evaluation and the indications for treatment of significant CAD in TAVI candidates remain a matter of debate. In this clinical consensus statement, a group of experts from the European Association of Percutaneous Cardiovascular Interventions (EAPCI) in collaboration with the European Society of Cardiology (ESC) Working Group on Cardiovascular Surgery aims to review the available evidence on the topic and proposes a rationale for the diagnostic evaluation and indications for percutaneous revascularisation of CAD in patients with severe aortic stenosis undergoing transcatheter treatment. Moreover, it also focuses on commissural alignment of transcatheter heart valves and coronary re-access after TAVI and redo-TAVI.


Assuntos
Estenose da Valva Aórtica , Cardiologia , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/etiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento
6.
J Interv Cardiol ; 2022: 9899235, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35250395

RESUMO

Bioprosthetic surgical aortic valve failure requiring reintervention is a frequent clinical problem with event rates up to 20% at 10 years after surgery. Transcatheter aortic valve-in-valve implantation (ViV-TAVI) has become a valuable treatment option for these patients, although it requires careful procedural planning. We here describe and illustrate a stepwise approach to plan and perform ViV-TAVI and discuss preprocedural computerized tomography planning, transcatheter heart valve selection, and implantation techniques. Particular attention is paid to coronary artery protection and the possible need for bioprosthetic valve fracture since patients with small surgical aortic bioprostheses are at a risk of high residual gradients after ViV-TAVI. Considering updated clinical data on long-term outcomes following ViV-TAVI, this approach may become the default treatment strategy for patients with a failing surgical aortic bioprosthesis.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Desenho de Prótese , Falha de Prótese , Instrumentos Cirúrgicos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
7.
EuroIntervention ; 17(16): 1289-1297, 2022 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-34673502

RESUMO

BACKGROUND: The mean age of transcatheter aortic valve implantation (TAVI) patients is steadily decreasing. AIMS: The aim of the study was to describe the characteristics, the indications for and the outcomes of TAVI in patients <70 years old. METHODS: All patients undergoing TAVI (n=8,626) from the 18 participating centres between January 2007 and June 2020 were stratified by age (70). For patients <70, the indications for TAVI were extracted from Heart Team discussions and the baseline characteristics and mortality were compared between the two groups. RESULTS: Overall, 640 (7.4%) patients were <70 (9.1% during 2018-2020, p<0.001); the mean age was 65.0±2.3 years. The younger patients were more often male, with bicuspid valves or needing valve-in-valve procedures. They had a higher prevalence of lung disease and diabetes. In 80.7% of cases, the Heart Team estimated an increased surgical risk and TAVI was selected, reflected by an STS score >4% in 20.4%. Five-year mortality was similar (29.4 vs 29.8%, HR 0.95, p=0.432) in the <70 and >70 groups. In the <70 group, mortality was higher for those referred for TAVI due to an increased surgical risk compared to those referred for other reasons (31.6 vs 24.5%, HR 1.23, p=0.021). Mortality was similar regardless of the STS stratum in patients judged by the Heart Team to be at increased surgical risk (32.6 vs 30.4%, HR 0.98, p=0.715). CONCLUSIONS: Use of TAVI in patients <70 is becoming more frequent. The main reason for choosing TAVI is due to an increased surgical risk not adequately represented by the STS score. The outcomes for these patients are similar to those for older TAVI patients. Dedicated trials of TAVI/SAVR in younger patients are needed to guide decisions concerning expansion of TAVI indications. ((ClinicalTrials.gov: NCT04031274).


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
EuroIntervention ; 17(17): e1397-e1406, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34734559

RESUMO

BACKGROUND: The presence of severe calcific atherosclerosis at the iliofemoral axis may preclude transcatheter aortic valve implantation (TAVI) by the transfemoral (TF) approach. Intravascular lithotripsy (IVL) is a novel technology that fractures intimal/medial calcium and increases vessel compliance allowing TF TAVI in selected patients with peripheral artery disease (PAD). AIMS: The aim of this study was to report on the safety and efficacy of IVL-assisted TF TAVI in an all-comers population. METHODS: Clinical, imaging and procedural data on all consecutive patients treated by IVL-assisted TF TAVI in six high-volume European centres (2018-2020) were collected in this prospective, real-world, multicentre registry. RESULTS: IVL-assisted TF TAVI was performed in 108 patients, increasing from 2.4% to 6.5% of all TAVI from 2018 to 2020, respectively. The target lesion was most often localised at the common and/or external iliac artery (93.5% of cases; average TL-MLD 4.6±0.9 mm with 318 degrees of calcium arc). Transfemoral aortic valve delivery was successful in 100% of cases; final procedural success in 98.2% (two conversions to cardiac open surgery for annular rupture and valve migration). Complications of the IVL-treated segments consisted of 1 perforation and 3 major dissections requiring stent implantation (2 covered stents and 2 BMS). Access-site-related complications included 3 major bleedings. Three in-hospital deaths were recorded (2.8%, 1 failed surgical conversion after annular rupture, 1 cardiac arrest after initial valvuloplasty, 1 late hyperkalaemia in renal dysfunction). CONCLUSIONS: IVL-assisted TF TAVI proved to be a safe and effective approach, which helps to expand the indications for TF TAVI in patients with severe calcific PAD. However, these patients continue to have a higher-than-average incidence of periprocedural complications.


Assuntos
Estenose da Valva Aórtica , Litotripsia , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Artéria Femoral/cirurgia , Humanos , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
9.
Int J Cardiol ; 338: 58-62, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34090956

RESUMO

BACKGROUND: Horizontal aorta (HA) is an anatomical feature that can pose significant technical challenges for the successful positioning of the bioprosthetic valve during transcatheter aortic valve replacement (TAVR). Physiological range of aortic angle (AA) is unknown; hence there is no cutoff AA for classifying HA. Moreover, patient characteristics predicting HA are under-investigated. METHODS: This was a retrospective analysis of prospective collected data from 16 heart valve centers in Europe. The study utilized a common dataset with a priori agreed-upon definitions and variables. Eligible patients underwent TAVR between 2014 and 2020 and had multidetector computed tomographic imaging data available for determining the AA. The analysis described the distribution of AA and potential predictors of HA. Inter-center variability was also explored. RESULTS: For 4022 patients analyzed, the mean AA ± standard deviation was 49.4° ± 9.4° (median 49°, inter-quartile range [IQR] 12°, range 18-90°). There was no significant difference in mean AA between men and women (49.4° ± 9.1° vs. 49.6° ± 9.3°, respectively; p = 0.53); therefore, 49.4° was accepted as the cutoff value for HA in subsequent analyses. Covariates significantly associated with HA included age (odds ratio [OR]: 1.02, 95% confidence interval [CI]: 1.01-1.04, p < 0.001), body mass index (OR: 1.06, 95% CI: 1.05-1.08, p < 0.01), previous cardiac surgery (OR: 0.58, 95% CI: 0.45-0.75, p < 0.001), and porcelain aorta (OR: 0.66, 95% CI: 0.52-0.85, p = 0.001). Some inter-center variability was observed. CONCLUSIONS: We defined 49.4° as the mean AA, and also associated predictors of HA in a large case series of patients with severe aortic stenosis candidates for TAVR.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Aorta , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Europa (Continente) , Feminino , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
10.
Front Cardiovasc Med ; 8: 658016, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33969021

RESUMO

Contemporary surgical and transcatheter aortic valve interventions offer effective therapy for a broad range of patients with severe symptomatic aortic valve disease. Both approaches have seen significant advances in recent years. Guidelines have previously emphasized 'surgical risk' in the decision between surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR), although this delineation becomes increasingly obsolete with more evidence on the effectiveness of TAVR in low surgical risk candidates. More importantly, decisions in tailoring aortic valve interventions should be patient-centered, accounting not only for operative risk, but also anatomy, lifetime management and specific co-morbidities. Aspects to be considered in a patient-tailored aortic valve intervention are discussed in this article.

11.
J Am Coll Cardiol ; 77(1): 1-14, 2021 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-33413929

RESUMO

BACKGROUND: Surgical aortic valve replacement and transcatheter aortic valve replacement (TAVR) are now both used to treat aortic stenosis in patients in whom life expectancy may exceed valve durability. The choice of initial bioprosthesis should therefore consider the relative safety and efficacy of potential subsequent interventions. OBJECTIVES: The aim of this study was to compare TAVR in failed transcatheter aortic valves (TAVs) versus surgical aortic valves (SAVs). METHODS: Data were collected on 434 TAV-in-TAV and 624 TAV-in-SAV consecutive procedures performed at centers participating in the Redo-TAVR international registry. Propensity score matching was applied, and 330 matched (165:165) patients were analyzed. Principal endpoints were procedural success, procedural safety, and mortality at 30 days and 1 year. RESULTS: For TAV-in-TAV versus TAV-in-SAV, procedural success was observed in 120 (72.7%) versus 103 (62.4%) patients (p = 0.045), driven by a numerically lower frequency of residual high valve gradient (p = 0.095), ectopic valve deployment (p = 0.081), coronary obstruction (p = 0.091), and conversion to open heart surgery (p = 0.082). Procedural safety was achieved in 116 (70.3%) versus 119 (72.1%) patients (p = 0.715). Mortality at 30 days was 5 (3%) after TAV-in-TAV and 7 (4.4%) after TAV-in-SAV (p = 0.570). At 1 year, mortality was 12 (11.9%) and 10 (10.2%), respectively (p = 0.633). Aortic valve area was larger (1.55 ± 0.5 cm2 vs. 1.37 ± 0.5 cm2; p = 0.040), and the mean residual gradient was lower (12.6 ± 5.2 mm Hg vs. 14.9 ± 5.2 mm Hg; p = 0.011) after TAV-in-TAV. The rate of moderate or greater residual aortic regurgitation was similar, but mild aortic regurgitation was more frequent after TAV-in-TAV (p = 0.003). CONCLUSIONS: In propensity score-matched cohorts of TAV-in-TAV versus TAV-in-SAV patients, TAV-in-TAV was associated with higher procedural success and similar procedural safety or mortality.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/mortalidade , Conversão para Cirurgia Aberta/estatística & dados numéricos , Oclusão Coronária/epidemiologia , Feminino , Hemorragia/epidemiologia , Humanos , Masculino , Marca-Passo Artificial/estatística & dados numéricos , Segurança do Paciente , Pontuação de Propensão , Sistema de Registros
12.
Catheter Cardiovasc Interv ; 98(3): E420-E426, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33220011

RESUMO

OBJECTIVES: This study aimed to find imaging risk features for device related-pulmonary artery (PA) injury (DR-PAI) in patients after left atrial appendage closure (LAAC). BACKGROUND: Cardiac tamponade resulting from DR-PAI is a rare but life-threatening complication of LAAC. METHODS: In vitro analysis of Amplatzer™ Amulet™ (Abbott, MN) device was done. Measurements of the distance between PA and Amplatzer lobe at its middle part, distal part, and along the stabilizing wires' trajectory (wires-to-PA distance) were taken in 100 consecutive patients on post-LAAC computed tomography (CT) studies. Clinical outcomes were collected. RESULTS: In vitro analysis indicated that both middle and distal lobe had to be in close PA proximity (<1.5 mm) for the stabilizing wires to cause risk for DR-PAI, configuration called ''cuddling lobe orientation''. On CT measurements middle lobe-PA distance was 4.7 mm (IQR = 2.7-9.5), with close proximity in 4 (4%) patients, and distal lobe-PA distance was 3.2 mm (IQR = 1.8-7.2 mm), with close proximity in 17 (17%) patients. Stabilizing wires were pointing toward PA in 47 patients (47%) with median wire-to-PA distance 5.7 mm (IQR = 3.6-8.5 mm). ''Cuddling'' was found in 2 (2%) patients and resulted in shorter wires-to-PA distance vs no ''cuddling'' group (2.3 vs 5.8 mm p <.01). At 2.9 ± 1.0 yrs of follow-up, the two patients with ''cuddling lobe orientation'' on post-LAAC CT scan developed late cardiac tamponades (p <.001). One of those required surgery, which confirmed DR-PAI. CONCLUSIONS: ''Cuddling lobe orientation'' of Amulet device with the PA was associated with short wires-to-PA distance and late pericardial effusions, including DR-PAI. Hence, such device-to-PA configuration should be avoided.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Cateterismo Cardíaco/efeitos adversos , Humanos , Artéria Pulmonar/diagnóstico por imagem , Resultado do Tratamento
13.
EuroIntervention ; 16(18): e1533-e1540, 2021 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-32364502

RESUMO

AIMS: The expansion of TAVI will involve an increase in the frequency of emergent or late cardiac surgery after THV implantation. This study was designed to investigate the anatomical feasibility of surgical cross-clamp and aortotomy after TAVI through a post-TAVI CT-scan assessment. METHODS AND RESULTS: We retrospectively analysed 117 CTs acquired after TAVI procedures with high stent prostheses in three high-volume centres between October 2008 and May 2017. The mean distance observed between the innominate artery and the top of the transcatheter heart valve was 45±11 mm, being <30 mm in 8/117 (6.8%) patients and <20 mm in none. The mean distance between the sinotubular junction and the first free site for aortotomy was 22±7 mm (>20 mm in 78/117 [66.7%] cases). A total of 56/117 (47.9%) patients showed a complete continuous contact between the anterior aortic wall and the anterior part of the valve stent. CONCLUSIONS: Aortic cross-clamp appears not to be an issue when cardiac surgery is needed after TAVI; however, a careful and possibly higher aortotomy may be required. CT should be performed prior to planned cardiac surgery after TAVI to determine a safe positioning for aortic cross-clamp and aortotomy.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Aorta/diagnóstico por imagem , Aorta/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
J Cardiovasc Med (Hagerstown) ; 22(6): 496-502, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33278208

RESUMO

BACKGROUND: The evaluation of aortic valve calcium burden is important when planning for transcatheter aortic valve implantation (TAVI). Although a robust golden standard methodology is available for calcium evaluation on noncontrast-enhanced (NCE) computed tomographic (CT) series, a standard reference for calcium assessment on contrast-enhanced CT series is currently lacking. METHODS: Two hundred and forty-four preprocedural CT scans from patients who had received TAVI were analysed. We correlated the aortic calcium volumes obtained on CE series at three thresholds [450, 850, and 'probe + 100' Hounsfield Units (HU)] with the Agatston score obtained on NCE scans. A subgroup analysis was performed taking into account the contrast enhancement of the left ventricular outflow tract (LVOT), with a prespecified cut-off of 300 HU. RESULTS: The overall population analysis showed higher correlation with the Agatston score using the 850 HU threshold (r = 0.45, P < 0.0001); no correlation was found with the 450 HU threshold, whilst the 'probe + 100' HU threshold showed a weaker correlation (r = 0.30, P < 0.0001). In patients with LVOT enhancement less than 300 HU, 450 HU showed the highest accuracy in calcium identification (r = 0.70, P < 0.0001), whereas in patients with LVOT enhancement of at least 300 HU, the most accurate threshold was 850 HU (r = 0.46, P < 0.0001). CONCLUSION: The thresholds for correct calcium identification using the automatic 3Mensio software depend on the contrast enhancement of aortic and cardiac structures, which can be estimated by measuring the HU in the LVOT. In patients with LVOT HU of less than 300, the correct threshold to be set in the software is 450 HU, whereas in patients with LVOT HU of at least 300 the correct threshold is 850 HU.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica/patologia , Calcinose/diagnóstico por imagem , Cálcio/análise , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Confiabilidade dos Dados , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Tamanho do Órgão , Avaliação de Resultados em Cuidados de Saúde , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos
15.
Circulation ; 143(2): 104-116, 2021 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-32975133

RESUMO

BACKGROUND: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. METHODS: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. RESULTS: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76-996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510-1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR (P<0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients (P=0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P<0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P=0.02). The rates of Mitral Valve Academic Research Consortium-defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P=0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74-12.56; P=0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88-21.53; P<0.001) were both independently associated with repeat mitral valve replacement. CONCLUSIONS: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.


Assuntos
Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas/normas , Valva Mitral/cirurgia , Sistema de Registros , Reoperação/normas , Substituição da Valva Aórtica Transcateter/normas , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Próteses Valvulares Cardíacas/tendências , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/tendências , Humanos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Reoperação/tendências , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/tendências
16.
Catheter Cardiovasc Interv ; 97(5): E736-E738, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32621567

RESUMO

Aortic annulus rupture or aortic root perforation is a rare complication of transcatheter aortic valve replacement (TAVR), requiring emergent cardiac surgery and carrying a high intraoperative mortality. Few cases can be managed conservatively, provided a strict clinical follow-up. This study describes the case of a 78-year-old patient with a degenerated bicuspid aortic valve stenosis who presented with a late aortic root perforation following TAVR, which was successfully managed applying a "watchful waiting" approach. Cardiac computed tomography imaging played a pivotal role in the diagnosis and subsequent decision on treatment and clinical follow-up.


Assuntos
Falso Aneurisma , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Idoso , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Tomografia Computadorizada Multidetectores , Trombose/diagnóstico por imagem , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
18.
Open Heart ; 7(2)2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32763967

RESUMO

BACKGROUND: Optimal preprocedural planning is essential to ensure successful device closure of the left atrial appendage (LAA). DESIGN: The PREDICT-LAA study is a prospective, international, multicentre, randomised controlled trial (ClinicalTrials.gov NCT04180605). Two hundred patients eligible for LAA closure with an Amplatzer Amulet device (Abbott, USA) will be enrolled in the study. Patients will be allocated to a computational simulation arm (experimental) or standard treatment arm (control) using a 1:1 randomisation. For patients randomised to the computational simulation arm, preprocedural planning will be based on the analysis of cardiac computed tomography (CCT)-based patient-specific computational simulations (FEops HEARTguide, Ghent, Belgium) in order to predict optimal device size and position. For patients in the control arm, preprocedural planning will be based on local practice including CCT analysis. The LAA closure procedure and postprocedural antithrombotic therapy will follow local practice in both arms. The primary endpoint of the study is incomplete LAA closure and device-related thrombus as assessed at 3 months postprocedural CCT. Secondary endpoints encompass procedural efficiency (number of devices used, number of repositioning, procedural time, radiation exposure, contrast dye), procedure-related complications within 7 days postprocedure and a composite of all-cause death and thromboembolic events at 12 months. CONCLUSION: The objective of the PREDICT-LAA study is to test the hypothesis that a preprocedural planning for LAA closure with the Amplatzer Amulet device based on patient-specific computational simulations can result in a more efficient procedure, optimised procedural outcomes and better clinical outcomes as compared with a standard preprocedural planning. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Registry (NCT04180605).


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Modelagem Computacional Específica para o Paciente , Terapia Assistida por Computador , Tomografia Computadorizada por Raios X , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Função do Átrio Esquerdo , Canadá , Cateterismo Cardíaco/efeitos adversos , Europa (Continente) , Frequência Cardíaca , Humanos , Estudos Multicêntricos como Assunto , Valor Preditivo dos Testes , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
19.
JACC Cardiovasc Interv ; 13(15): 1803-1812, 2020 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-32682679

RESUMO

OBJECTIVES: The aim of this study was to assess the added value and predictive power of the TAVIguide (Added Value of Patient-Specific Computer Simulation in Transcatheter Aortic Valve Implantation) software in clinical practice. BACKGROUND: Optimal outcome after transcatheter aortic valve replacement (TAVR) may become more important as TAVR shifts toward low-risk patients. Patient-specific computer simulation is able to provide prediction of outcome after TAVR. Its clinical role and validation of accuracy, however, have not yet been studied prospectively. METHODS: A prospective, observational, multicenter study was conducted among 80 patients with severe aortic stenosis treated with the Evolut R valve. Simulation was performed in 42 patients and no simulation in 38. A comparison between the valve size (decision 1) and target depth of implantation selected by the operator on the basis of multislice computed tomography and the valve size (decision 2) and target depth of implantation selected after simulation were the primary endpoints. Predictive power was examined by comparing the simulated and observed degree of aortic regurgitation. RESULTS: Decision 2 differed from decision 1 in 1 of 42 patients because of predicted paravalvular leakage, and changes in valve type occurred in 2 of 42. In 39 of 42 patients, decisions 1 and 2 were similar. Target depth of implantation differed in 7 of 42 patients after simulation (lower in 4 and higher in 3). In 16 of 42 patients, simulation affected the TAVR procedure; in 9, the operator avoided additional measures to achieve the target depth of implantation, and in 7 patients, additional measures were performed. There was a trend toward a higher degree of predicted than observed aortic regurgitation (17.5 vs. 12 ml/s; p = 0.13). CONCLUSIONS: Patient-specific computer simulation did not affect valve size selection but did affect the selection of the target depth of implantation and the execution of TAVR to achieve the desired target depth of implantation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Tomada de Decisão Clínica , Europa (Continente) , Feminino , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
20.
J Am Coll Cardiol ; 75(16): 1882-1893, 2020 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-32327098

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) use is increasing in patients with longer life expectancy, yet robust data on the durability of transcatheter heart valves (THVs) are limited. Redo-TAVR may play a key strategy in treating patients in whom THVs fail. OBJECTIVES: The authors sought to examine outcomes following redo-TAVR. METHODS: The Redo-TAVR registry collected data on consecutive patients who underwent redo-TAVR at 37 centers. Patients were classified as probable TAVR failure or probable THV failure if they presented within or beyond 1 year of their index TAVR, respectively. RESULTS: Among 63,876 TAVR procedures, 212 consecutive redo-TAVR procedures were identified (0.33%): 74 within and 138 beyond 1 year of the initial procedure. For these 2 groups, TAVR-to-redo-TAVR time was 68 (38 to 154) days and 5 (3 to 6) years. The indication for redo-TAVR was THV stenosis in 12 (16.2%) and 51 (37.0%) (p = 0.002) and regurgitation or combined stenosis-regurgitation in 62 (83.8%) and 86 (62.3%) (p = 0.028), respectively. Device success using VARC-2 criteria was achieved in 180 patients (85.1%); most failures were attributable to high residual gradients (14.1%) or regurgitation (8.9%). At 30-day and 1-year follow-up, residual gradients were 12.6 ± 7.5 mm Hg and 12.9 ± 9.0 mm Hg; valve area 1.63 ± 0.61 cm2 and 1.51 ± 0.57 cm2; and regurgitation ≤mild in 91% and 91%, respectively. Peri-procedural complication rates were low (3 stroke [1.4%], 7 valve malposition [3.3%], 2 coronary obstruction [0.9%], 20 new permanent pacemaker [9.6%], no mortality), and symptomatic improvement was substantial. Survival at 30 days was 94.6% and 98.5% (p = 0.101) and 83.6% and 88.3% (p = 0.335) at 1 year for patients presenting with early and late valve dysfunction, respectively. CONCLUSIONS: Redo-TAVR is a relatively safe and effective option for selected patients with valve dysfunction after TAVR. These results are important for applicability of TAVR in patients with long life expectancy in whom THV durability may be a concern.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias , Reoperação , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Análise de Falha de Equipamento , Feminino , Saúde Global , Humanos , Masculino , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Sistema de Registros/estatística & dados numéricos , Reoperação/instrumentação , Reoperação/métodos , Reoperação/estatística & dados numéricos , Análise de Sobrevida , Avaliação de Sintomas/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA