Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
Chin Med J (Engl) ; 2023 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-37606001

RESUMO

BACKGROUND: Due to the wide variety of morphology, size, and dynamics, selecting an optimal valve size and location poses great difficulty in percutaneous pulmonary valve implantation (PPVI). This study aimed to report our experience with in vitro bench testing using patient-specific three-dimensional (3D)-printed models for planning PPVI with the Venus P-valve. METHODS: Patient-specific 3D soft models were generated using PolyJet printing with a compliant synthetic material in 15 patients scheduled to undergo PPVI between July 2018 and July 2020 in Central China Fuwai Hospital of Zhengzhou University. RESULTS: 3D model bench testing altered treatment strategy in all patients (100%). One patient was referred for surgery because testing revealed that even the largest Venus P-valve would not anchor properly. In the remaining 14 patients, valve size and/or implantation location was altered to avoid valve migration and/or compression coronary artery. In four patients, it was decided to change the point anchoring because of inverted cone-shaped right ventricular outflow tract (RVOT) (n = 2) or risk of compression coronary artery (n = 2). Concerning sizing, we found that an oversize of 2-5 mm suffices. Anchoring of the valve was dictated by the flaring of the in- and outflow portion in the pulmonary artery. PPVI was successful in all 14 patients (absence of valve migration, no coronary compression, and none-to-mild residual pulmonary regurgitation [PR]). The diameter of the Venus P-valve in the 3D simulation group was significantly smaller than that of the conventional planning group (36 [2] vs. 32 [4], Z = -3.77, P <0.001). CONCLUSIONS: In vitro testing indicated no need to oversize the Venus P-valve to the degree recommended by the balloon-sizing technique, as 2-5 mm sufficed.

2.
Cardiovasc Revasc Med ; 34: 69-74, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33612412

RESUMO

BACKGROUND/PURPOSE: The MANTA is a dedicated plug-based large-bore vascular closure device (VCD) providing safe hemostasis in most patients, but data on the clinical impact and mechanisms of MANTA related complications are limited. This study sought to determine the frequency, impact and predictors of MANTA-related access complications. METHODS/MATERIALS: This patient-level meta-analysis included data from 2 medical device approval studies and 1 post-approval registry. The primary endpoint was the composite of major and minor access complications. Technical success was defined as hemostasis with MANTA closure device without need for vascular surgery or stenting. RESULTS: Eight hundred ninety-one patients (mean age 80) underwent transcatheter aortic valve replacement (n = 814), endovascular aortic repair (n = 71), balloon aortic valvuloplasty (n = 4) or mechanical circulatory support (n = 2). Technical success was 96.4% and median time to hemostasis was 31 (interquartile range: 17-76) seconds. The primary endpoint occurred 9.1% and bailout vascular surgery or stenting was necessary in 32 patients (3.6%). Female gender (OR: 2.63, CI: 1.46-4.73, p = 0.001), left femoral access (OR: 2.18, CI: 1.17-4.06, p = 0.015) and unfavorable arteriotomy phenotype (combination of a small femoral artery diameter with a deep arteriotomy; OR 2.27: 1.26-4.10, p = 0.006) independently predicted access complications. Access complications most often consisted of vessel dissection, stenosis or occlusion and predominantly occurred in patients with an unfavorable arteriotomy phenotype. CONCLUSIONS: Large-bore arteriotomy closure with MANTA VCD provided fast and safe hemostasis with an acceptable complication rate. Refined procedure planning and risk-stratification may further improve MANTA VCD performance.


Assuntos
Estenose da Valva Aórtica , Cateterismo Periférico , Procedimentos Endovasculares , Dispositivos de Oclusão Vascular , Estenose da Valva Aórtica/cirurgia , Cateterismo Periférico/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Hemorragia/etiologia , Técnicas Hemostáticas/efeitos adversos , Humanos , Resultado do Tratamento
3.
J Am Soc Echocardiogr ; 35(1): 105-115.e8, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34389469

RESUMO

BACKGROUND: Functional mitral regurgitation (FMR) can be subclassified on the basis of its proportionality relative to left ventricular (LV) volume and function, indicating potential differences in underlying etiology. The aim of this study was to evaluate the association of FMR proportionality with FMR reduction, heart failure hospitalization and mortality after transcatheter edge-to-edge mitral valve repair (TEER). METHODS: This multicenter registry included 241 patients with symptomatic heart failure with reduced LV ejection fraction treated with TEER for moderate to severe or greater FMR. FMR proportionality was graded on preprocedural transthoracic echocardiography using the ratio of the effective regurgitant orifice area to LV end-diastolic volume. Baseline characteristics, follow-up transthoracic echocardiography, and 2-year clinical outcomes were compared between groups. RESULTS: Median LV ejection fraction, effective regurgitant orifice area and LV end-diastolic volume index were 30% (interquartile range [IQR], 25%-35%), 27 mm2, and 107 mL/m2 (IQR, 90-135 mL/m2), respectively. Median effective regurgitant orifice area/LV end-diastolic volume ratio was 0.13 (IQR, 0.10-0.18). Proportionate FMR (pFMR) and disproportionate FMR (dFMR) was present in 123 and 118 patients, respectively. Compared with patients with pFMR, those with dFMR had higher baseline LV ejection fractions (median, 32% [IQR, 27%-39%] vs 26% [IQR, 22%-33%]; P < .01). Early FMR reduction with TEER was more pronounced in patients with dFMR (odds ratio, 0.45; 95% CI, 0.28-0.74; P < .01) than those with pFMR, but not at 12 months (odds ratio, 0.93; 95% CI, 0.53-1.63; P = .80). Overall, in 35% of patients with initial FMR reduction after TEER, FMR deteriorated again at 1-year follow-up. Rates of 2-year all-cause mortality and heart failure hospitalization were 30% (n = 66) and 37% (n = 76), with no differences between dFMR and pFMR. CONCLUSIONS: TEER resulted in more pronounced early FMR reduction in patients with dFMR compared with those with pFMR. Yet after initial improvement, FMR deteriorated in a substantial number of patients, calling into question durable mitral regurgitation reductions with TEER in selected patients. The proportionality framework may not identify durable TEER responders.


Assuntos
Insuficiência da Valva Mitral , Ecocardiografia , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
4.
J Am Heart Assoc ; : e019236, 2021 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-33794658

RESUMO

Background Recurrence of mitral regurgitation (MR) after surgical mitral valve repair (SMVR) varies and may require reoperation. Redo mitral valve surgery can be technically challenging and is associated with increased risk of mortality and morbidity. We aimed to assess the feasibility and safety of MitraClip as a treatment strategy after failed SMVR and identify procedure modifications to overcome technical challenges. Methods and Results This international multicenter observational retrospective study collected information for all patients from 16 high-volume hospitals who were treated with MitraClip after failed SMVR from October 29, 2009, until August 1, 2017. Data were anonymously collected. Technical and device success were recorded per modified Mitral Valve Academic Research Consortium criteria. Overall, 104 consecutive patients were included. Median Society of Thoracic Surgeons score was 4.5% and median age was 73 years. At baseline, the majority of patients (82%) were in New York Heart Association class ≥III and MR was moderate or higher in 86% of patients. The cause of MR pre-SMVR was degenerative in 50%, functional in 35%, mixed in 8%, and missing/unknown in 8% of patients. The median time between SMVR and MitraClip was 5.3 (1.9-9.7) years. Technical and device success were 90% and 89%, respectively. Additional/modified imaging was applied in 21% of cases. An MR reduction of ≥1 grade was achieved in 94% of patients and residual MR was moderate or less in 90% of patients. In-hospital all-cause mortality was 2%, and 86% of patients were in New York Heart Association class ≤II. Conclusions MitraClip is a safe and less invasive treatment option for patients with recurrent MR after failed SMVR. Additional/modified imaging may help overcome technical challenges during leaflet grasping.

5.
Angiology ; 72(5): 465-473, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33464117

RESUMO

Little data are available on access strategy outcomes for cardiac catheterizations in patients with prior coronary artery bypass graft surgery (CABG). We investigated the effect of transradial access (TRA) and transfemoral access (TFA) on short-term major vascular complications (MVC) and long-term major adverse cardiovascular events (MACE). In this single-center, retrospective cohort study, 1084 patients met our inclusion criteria (TRA = 469; TFA = 615). The cumulative incidence for the primary safety endpoint MVC at 30 days (a composite of major bleeding, retroperitoneal hematoma, dissection, pseudoaneurysm, and arteriovenous fistula) was lower with TRA (0.7% vs 3.0%, P < .01) and this difference remained significant after propensity score adjustment (odds ratio: 0.24; 95% CI, 0.07-0.83; P = .024). The cumulative incidence for the primary efficacy endpoint MACE at 36 months (a composite of all-cause mortality, myocardial infarction, stroke, and urgent target vessel revascularization) was 28.6% with TRA and 27.6% with TFA, respectively. Kaplan-Meier curves showed no difference for the primary efficacy endpoint (P = .65). Contrast use (mL) was significantly lower with TRA (130 [100-180] vs 150 [100-213], P < .01). In conclusion, in patients with prior CABG, TRA was associated with significantly fewer short-term MVC and contrast use, but not with a difference in long-term MACE, compared with TFA.


Assuntos
Cateterismo Cardíaco , Cateterismo Periférico , Ponte de Artéria Coronária , Artéria Femoral , Artéria Radial , Idoso , Cateterismo Cardíaco/efeitos adversos , Doenças Cardiovasculares/epidemiologia , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Meios de Contraste/administração & dosagem , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Feminino , Humanos , Incidência , Masculino , Punções , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Lesões do Sistema Vascular/epidemiologia
6.
Catheter Cardiovasc Interv ; 97(6): 1270-1278, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33347739

RESUMO

OBJECTIVES: To study safety and performance of the MANTA Vascular closure device (VCD) under real world conditions in 10 centers. BACKGROUND: The MANTA is a novel plug-based device for large bore arteriotomy closure. METHODS: We included all eligible patients who underwent transfemoral large bore percutaneous procedures. Exclusion criteria were per operator's discretion and included severe calcification or marked tortuosity of the access vessel, presence of marked obesity/cachexia or a systolic blood pressure above 180 mmHg. The primary performance endpoint was time to hemostasis. Primary and secondary safety endpoints were major and minor access site related vascular complications up to 30 days, respectively. Vascular complications were adjudicated by an independent clinical event committee according to VARC-2 criteria. We performed multivariable logistic regression to estimate the effect of baseline and procedural characteristics on any and major vascular complications. RESULTS: Between February 2018 and July 2019 500 patients were enrolled undergoing Transcatheter aortic valve replacement (TAVR, N = 496), Balloon aortic valvuloplasty (BAV, N = 2), Mechanical circulatory support (MCS, N = 1) or Endovascular aneurysm repair (EVAR, N = 1). Mean age was 80.8 ± 6.6 years with a median STS-score of 2.7 [IQR 2.0-4.3] %. MANTA access site complications were major in 20 (4%) and minor in 28 patients (5.6%). Median time to hemostasis was 50 [IQR 20-120] sec. Severe femoral artery calcification, scar presence in groin, longer procedure duration, female gender and history of hypertension were independent predictors for vascular complications. CONCLUSION: In this study, MANTA appeared to be a safe and effective device for large bore access closure under real-world conditions.


Assuntos
Aneurisma da Aorta Abdominal , Estenose da Valva Aórtica , Implante de Prótese Vascular , Cateterismo Periférico , Procedimentos Endovasculares , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Cateterismo Periférico/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Hemorragia/etiologia , Técnicas Hemostáticas/efeitos adversos , Humanos , Sistema de Registros , Resultado do Tratamento
7.
JACC Cardiovasc Interv ; 13(15): 1803-1812, 2020 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-32682679

RESUMO

OBJECTIVES: The aim of this study was to assess the added value and predictive power of the TAVIguide (Added Value of Patient-Specific Computer Simulation in Transcatheter Aortic Valve Implantation) software in clinical practice. BACKGROUND: Optimal outcome after transcatheter aortic valve replacement (TAVR) may become more important as TAVR shifts toward low-risk patients. Patient-specific computer simulation is able to provide prediction of outcome after TAVR. Its clinical role and validation of accuracy, however, have not yet been studied prospectively. METHODS: A prospective, observational, multicenter study was conducted among 80 patients with severe aortic stenosis treated with the Evolut R valve. Simulation was performed in 42 patients and no simulation in 38. A comparison between the valve size (decision 1) and target depth of implantation selected by the operator on the basis of multislice computed tomography and the valve size (decision 2) and target depth of implantation selected after simulation were the primary endpoints. Predictive power was examined by comparing the simulated and observed degree of aortic regurgitation. RESULTS: Decision 2 differed from decision 1 in 1 of 42 patients because of predicted paravalvular leakage, and changes in valve type occurred in 2 of 42. In 39 of 42 patients, decisions 1 and 2 were similar. Target depth of implantation differed in 7 of 42 patients after simulation (lower in 4 and higher in 3). In 16 of 42 patients, simulation affected the TAVR procedure; in 9, the operator avoided additional measures to achieve the target depth of implantation, and in 7 patients, additional measures were performed. There was a trend toward a higher degree of predicted than observed aortic regurgitation (17.5 vs. 12 ml/s; p = 0.13). CONCLUSIONS: Patient-specific computer simulation did not affect valve size selection but did affect the selection of the target depth of implantation and the execution of TAVR to achieve the desired target depth of implantation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Tomada de Decisão Clínica , Europa (Continente) , Feminino , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Int J Cardiol ; 302: 36-41, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31859111

RESUMO

BACKGROUND: The capacity of TAVI-programs and numbers of sites performing TAVI has rapidly increased. This necessitated the initiation of the Rotterdam TAVI Care & Cure Program, aiming to improve patient-centered care during the TAVI pathway. METHODS: Consenting patients with severe aortic stenosis and an indication for TAVI will be included. The TAVI Care & Cure program will facilitate prognostic contributions to improve outcomes, patient satisfaction and quality of life in patients with valvular heart disease who are treated with a transcatheter aortic valve implantation in collaboration with the departments of cardiology, cardio-thoracic surgery, anesthesiology and geriatrics. CONCLUSION: With a single center observational registry, we aim to assess the TAVI patient clinical pathway, focusing on pre, peri and post interventional variables including functional status and HRQoL. We will evaluate the patient's complexity by applying an extended multidisciplinary approach, which includes a systematic application of geriatric assessments of frailty and cognitive function.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Fragilidade/complicações , Avaliação Geriátrica , Qualidade de Vida , Sistema de Registros , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Estenose da Valva Aórtica/complicações , Feminino , Fragilidade/psicologia , Humanos , Masculino , Países Baixos , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 96(3): E204-E212, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-31789481

RESUMO

OBJECTIVES: The aim of this study was to evaluate the very long-term clinical outcome after radioactive stent (RS) implantation and intracoronary ß radiation brachytherapy (IRBT). BACKGROUND: Radioactive stents (RS) and intracoronary ß radiation brachytherapy (IRBT) were introduced to prevent restenosis after percutaneous coronary intervention (PCI). Both techniques were associated with a higher incidence of major adverse cardiac events (MACE) in the short and intermediate-term follow up as compared to conventional PCI. METHODS: One hundred and thirty-three patients received radioactive stents (32 P) and 301 patients were treated with IRBT adjunctive to PCI. These groups were propensity matched to respectively 266 and 602 control patients who were treated with routine PCI during the same inclusion period. Endpoints were all-cause mortality and MACE, defined as all-cause death, any myocardial infarction or any revascularization. RESULTS: Median follow-up duration was 17 years. All-cause mortality rates were similar in all groups. Adjusted hazard ratios for MACE and mortality in the RS cohort were 1.55 (95% CI 1.20-2.00) and 0.92 (95% CI 0.63-1.34), respectively. Adjusted hazard ratios for MACE and all-cause mortality in the IRBT cohort were 1.41 (95% CI 1.18-1.67) and 0.95 (95% CI 0.74-1.21), respectively. The difference in MACE rates was predominantly driven by coronary revascularizations in both groups, with a higher MI rate in the IRBT group as well. CONCLUSIONS: Coronary radiation therapy was associated with early increased MACE rates, but the difference in MACE rates decreased beyond 2 years, resulting in a comparable long-term clinical outcome. Importantly, no excess in mortality was observed.


Assuntos
Braquiterapia , Doença da Artéria Coronariana/terapia , Reestenose Coronária/prevenção & controle , Intervenção Coronária Percutânea/instrumentação , Stents , Idoso , Braquiterapia/efeitos adversos , Braquiterapia/mortalidade , Estudos de Casos e Controles , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
10.
Am Heart J ; 213: 66-72, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31128504

RESUMO

BACKGROUND: Post percutaneous coronary intervention (PCI) fractional flow reserve (FFR) is a significant predictor of major adverse cardiac events (MACE). The rationale for low post procedural FFR values often remains elusive based on angiographic findings alone, warranting further assessment using an FFR pullback or additional intravascular imaging. It is currently unknown if additional interventions intended to improve the PCI, decrease MACE rates. STUDY DESIGN: The FFR REACT trial is a prospective, single-center randomized controlled trial in which 290 patients with a post PCI FFR <0.90 will be randomized (1:1) to either standard of care (no additional intervention) or intravascular ultrasound (IVUS)-directed optimization of the FFR (treatment arm). Eligible patients are those treated with angiographically successful PCI for (un)stable angina or non-ST elevation myocardial infarction (MI). Assuming 45% of patients will have a post PCI FFR <0.90, approximately 640 patients undergoing PCI will need to be enrolled. Patients with a post PCI FFR ≥ 0.90 will be enrolled in a prospective registry. The primary end point is defined as a composite of cardiac death, target vessel MI and clinically driven target vessel revascularisation (target vessel failure) at 1 year. Secondary end points will consist of individual components of the primary end point, procedural success, stent thrombosis and correlations on clinical outcome, changes in post PCI Pd/Pa and FFR and IVUS derived dimensions. All patients will be followed for 3 years. CONCLUSION: The FFR-REACT trial is designed to explore the potential benefit of HD-IVUS-guided PCI optimization in patients with a post PCI FFR <0.90 (Dutch trial register: NTR6711).


Assuntos
Angina Estável/terapia , Endossonografia/métodos , Reserva Fracionada de Fluxo Miocárdico , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Intervenção Coronária Percutânea/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Angina Estável/fisiopatologia , Humanos , Revascularização Miocárdica , Infarto do Miocárdio sem Supradesnível do Segmento ST/fisiopatologia , Estudos Prospectivos , Padrão de Cuidado
11.
Circ Cardiovasc Interv ; 12(5): e007428, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-31018666

RESUMO

BACKGROUND: Fractional flow reserve (FFR) is the current gold standard to determine hemodynamic severity of angiographically intermediate coronary lesions. Much less is known about the prognostic effects of FFR measured directly after percutaneous coronary intervention (PCI). The aims of this study were to evaluate post-PCI FFR values, identify predictors for a low post-PCI FFR, and to investigate whether a relationship between postprocedural FFR and outcome during 30-day follow-up exists. METHODS AND RESULTS: The FFR-SEARCH (Fractional Flow Reserve-Stent Evaluated at Rotterdam Cardiology Hospital) is a prospective registry in which FFR measurements were performed after PCI in 1000 consecutive patients. All FFR measurements were performed under maximum hyperemia with intravenous adenosine with the Navvus RXi system (ACIST Medical Systems, Eden Prairie, MN). The clinical end point was defined as a composite of death, target vessel revascularization, or nonfatal myocardial infarction at 30-day follow-up. Measurement of post-PCI FFR was successful in 959 patients (96%), and a total of 1165 lesions were assessed. There were no complications related to the microcatheter. A total of 322 ST-segment-elevation myocardial infarction patients with 371 measured lesions were excluded leaving 637 patients with 794 measured lesions for the final analysis. Overall post-PCI FFR was 0.90±0.07. In 396 lesions (50%), post-PCI FFR was >0.90. A total of 357 patients (56%) had ≥1 lesion(s) with a post-PCI FFR ≤0.90, and 73 patients (11%) had ≥1 lesion(s) with a post-PCI FFR ≤0.80 with post-PCI FFR ≤0.80 in 78 lesions (9.8%). Complex lesion characteristics, use of multiple stents and smaller reference vessel diameter was associated with post-PCI FFR ≤0.90. During follow-up, 11 patients (1.8%) reached the clinical end point. There was no significant relationship between post-PCI FFR and the clinical end point at 30-day follow-up ( P=0.636). CONCLUSIONS: Routine measurement of post-PCI FFR using a monorail microcatheter is safe and feasible. Several lesion and patient characteristics were associated with a low post-PCI FFR. Post-PCI FFR did not correlate with clinical events at 30 days.


Assuntos
Síndrome Coronariana Aguda/terapia , Angina Estável/terapia , Cateterismo Cardíaco , Doença da Artéria Coronariana/terapia , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/mortalidade , Síndrome Coronariana Aguda/fisiopatologia , Adenosina/administração & dosagem , Idoso , Angina Estável/diagnóstico , Angina Estável/mortalidade , Angina Estável/fisiopatologia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Hiperemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Estudos Prospectivos , Recidiva , Sistema de Registros , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Vasodilatadores/administração & dosagem
12.
Catheter Cardiovasc Interv ; 94(6): 795-805, 2019 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-30901147

RESUMO

OBJECTIVES: To explore the prevalence of smoking, and its association with clinical and mortality outcome among patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Less data exist regarding the effect of baseline smoking status on clinical and mortality outcome among patients undergoing TAVR. METHODS: Consecutive patients who underwent TAVR at two high volume Dutch centers were included. Smoking status was prospectively questioned by a structured interview at admission. Primary endpoint was 1-year all-cause mortality after TAVR. RESULTS: A total of 913 consecutive patients (80.1 ± 7.6 years; logistic EuroSCORE: 16.5 ± 9.9%) who underwent TAVR for severe aortic valve stenosis were included. There were 47% (n = 432) males, and 57% (n = 522) never-smokers, and 35% (n = 317) prior-smokers, and 8% (n = 74) current-smokers. Smokers (i.e., prior-smokers or current-smokers) were younger compared to never-smokers (78.9 ± 7.9 and 76.4 ± 8.0 vs. 81.3 ± 7.1, P < 0.000, respectively). Median follow-up time was 365 (interquartile range [IQR]: 280-365) days. Overall, prior-smoking was not associated with all-cause mortality at 1-year following TAVR (hazard ratio [HR] 0.83, 95% confidence interval [CI] 0.55-1.23). After stratification according to sex, male prior-smokers showed better 1-year survival after TAVR than male never-smokers (12% vs. 20%; P = 0.018, respectively, HR 0.52, 95% CI 0.29-0.89), while this reversed effect was not observed among female prior-smokers versus female never-smokers after TAVR (HR 1.70, 95% CI 0.95-3.05). CONCLUSIONS: Overall, baseline prior-smokers had similar 1-year mortality outcome after TAVR compared with baseline never-smokers. However, there was a reversed association between baseline prior-smoking status and 1-year mortality after TAVR among males, which could partially be explained due to the favorable baseline characteristics.


Assuntos
Estenose da Valva Aórtica/cirurgia , Fumar Cigarros/efeitos adversos , Ex-Fumantes , não Fumantes , Fumantes , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Fumar Cigarros/mortalidade , Feminino , Humanos , Masculino , Países Baixos , Prevalência , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
13.
Interact Cardiovasc Thorac Surg ; 28(6): 852-859, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-30753554

RESUMO

OBJECTIVES: Our goal was to evaluate the outcomes of the first patients treated by venous coronary artery bypass grafting (CABG) or percutaneous coronary interventions (PCIs) with balloon angioplasty at a single centre who have reached up to 40 years of life-long follow-up. METHODS: We analysed the outcomes of the first consecutive patients who underwent (venous) CABG (n = 1041) from 1971 to 1980 and PCI (n = 856) with balloon angioplasty between 1980 and 1985. Follow-up was successfully achieved in 98% of patients (median 39 years, range 36-46) who underwent CABG and in 97% (median 33 years, range 32-36) of patients who had PCI. RESULTS: The median age was 53 years in the CABG cohort and 57 years in the PCI cohort. A total of 82% of patients in the CABG group and 37% of those in the PCI group had multivessel coronary artery disease. The cumulative survival rates at 10, 20, 30 and 40 years were 77%, 39%, 14% and 4% after CABG, respectively, and at 10, 20, 30 and 35 years after PCI were 78%, 47%, 21% and 12%, respectively. The estimated life expectancy after CABG was 18 and 17 years after the PCI procedures. Repeat revascularization was performed in 36% and 57% of the patients in the CABG and PCI cohorts, respectively. CONCLUSIONS: This unique life-long follow-up analysis demonstrates that both CABG and PCI were excellent treatment options immediately after their introduction as the standard of care. These procedures were lifesaving, thereby indirectly enabling patients to be treated with newly developed methods and medical therapies during the follow-up years.


Assuntos
Doença da Artéria Coronariana/cirurgia , Previsões , Revascularização Miocárdica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Intervenção Coronária Percutânea/métodos , Taxa de Sobrevida/tendências , Resultado do Tratamento , Adulto Jovem
14.
Circ Cardiovasc Interv ; 12(2): e007030, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30732469

RESUMO

BACKGROUND: Fractional flow reserve (FFR) after percutaneous coronary intervention is a predictor of adverse cardiovascular events during follow-up. However, the rationale for low post procedural FFR values remains often elusive based on angiographic findings alone. METHODS AND RESULTS: FFR SEARCH (Stent Evaluated at Rotterdam Cardiology Hospital) is a prospective single-center registry in which post-percutaneous coronary intervention FFR was assessed in 1000 consecutive all-comer patients. FFR measurements were performed with a microcatheter ±20 mm distal to the most distal stent edge. In 100 vessels with a post procedural FFR ≤0.85, and 20 vessels >0.85 high definition intravascular ultrasound analysis was performed. In 100 vessels with a post-percutaneous coronary intervention FFR ≤0.85, mean post procedural FFR was 0.79±0.05. Minimal lumen area was 2.19 (1.81-3.19) mm2, mean lumen area was 5.95 (5.01-7.03) mm2, and minimal stent area was 4.01 (3.09-5.21) mm2. Significant residual focal proximal lesions were found in 29% of the assessed vessels whereas, focal distal lesions were found in 30% of the vessels. Stent underexpansion and malapposition were found in 74% and 22% of vessels, respectively. Clear focal signs of luminal narrowing were found in 54% of the vessels analyzed. Although incidences of focal lesions, underexpansion, and malapposition were similar between both cohorts, minimal stent area was significantly smaller in vessels with a post-percutaneous coronary intervention FFR ≤0.85 as compared with those with an FFR >0.85. CONCLUSIONS: In patients with a post procedural FFR ≤0.85, intravascular ultrasound revealed focal signs of luminal narrowing in a significant number of cases.


Assuntos
Doença da Artéria Coronariana/terapia , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea/efeitos adversos , Idoso , Cateterismo Cardíaco , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/instrumentação , Valor Preditivo dos Testes , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Stents , Resultado do Tratamento , Ultrassonografia de Intervenção
15.
Cardiovasc Revasc Med ; 20(2): 126-132, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-29779973

RESUMO

AIMS: We sought to evaluate the interaction of different aortic root phenotypes with self-expanding (SEV), balloon-expandable (BEV) and mechanically expanded (MEV) and the impact on significant aortic regurgitation. METHODS AND RESULTS: We included 392 patients with a SEV (N = 205), BEV (N = 107) or MEV (N = 80). Aortic annulus eccentricity index and calcification were measured by multi-slice CT scan. Paravalvular aortic regurgitation was assessed by contrast aortography (primary analysis) and transthoracic echocardiography (secondary analysis). In mildly calcified roots paravalvular regurgitation incidence was similar for all transcatheter heart valves (SEV 8.4%; BEV 9.1%; MEV 2.0% p = 0.27). Conversely, in heavily calcified roots paravalvular regurgitation incidence was significantly higher with SEV (SEV 45.9%; BEV 0.0%; MEV 0.0% p < 0.001). When paravalvular regurgitation was assessed by TTE, the overall findings were similar although elliptic aortic roots were associated with more paravalvular regurgitation with SEV (20.5% vs. BEV 4.5% vs. MEV 3.2%; p = 0.009). CONCLUSIONS: In heavily calcified aortic roots, significant paravalvular aortic regurgitation is more frequent with SEV than with BEV or MEV, but similar in mildly calcified ones. These findings may support patient-tailored transcatheter heart valve selection. CLASSIFICATIONS: Aortic stenosis; multislice computed tomography; transcatheter aortic valve replacement; paravalvular aortic regurgitation. CONDENSED ABSTRACT: We sought to evaluate the interaction of different aortic root phenotypes with self-expanding (SEV), balloon-expandable (BEV) and mechanically expanded (MEV) and the impact on significant aortic regurgitation. We included 392 patients with a SEV (N = 205), BEV (N = 107) or MEV (N = 80). Aortic annulus eccentricity index and calcification were measured by multi-slice CT scan. Paravalvular aortic regurgitation was assessed by contrast aortography and transthoracic echocardiography. We found that in heavily calcified aortic roots, significant paravalvular aortic regurgitation is more frequent with SEV than with BEV or MEV, but similar in mildly calcified ones.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Calcinose/cirurgia , Próteses Valvulares Cardíacas , Hemodinâmica , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Aortografia/métodos , Valvuloplastia com Balão/efeitos adversos , Calcinose/diagnóstico por imagem , Calcinose/fisiopatologia , Angiografia por Tomografia Computadorizada , Ecocardiografia , Humanos , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
16.
Am Heart J ; 204: 83-91, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30081277

RESUMO

BACKGROUND: Dedicated data on the prevalence of incidental findings (IF) stratified according to overall clinical relevance and their subsequent correlation to outcome are lacking. The aim of the present study was to describe the prevalence and consequences of noncardiac IF on computed tomography or magnetic resonance imaging in the workup for interventional cardiovascular procedures. METHODS: A total of 916 patients underwent preprocedural computed tomography or magnetic resonance imaging in the workup for transcatheter aortic valve implantation (TAVI), renal sympathetic denervation (RDN), or MitraClip implantation. RESULTS: IF were found in 395 of 916 patients (43.1%), with an average of 1.8 IF per patient. Classifying the IF resulted in 155 patients with minor, 171 patients with moderate, and 69 patients with major IF. The intended procedure was delayed or canceled in only 15 of 916 (1.6%) of the patients because of the presence of potential malignant IF. In patients that did undergo the intended procedure (n = 774), the presence of a moderate or major IF (23.8%) did not impact 1-year mortality compared to no or minor IF (adjusted HR 0.90, 95% CI 0.56-1.44, P value = .65). These findings were consistent among patients referred for TAVI, RDN, or MitraClip. CONCLUSIONS: IF are frequent in patients referred for cardiovascular procedures. IF did not result in a delay or cancellation of the intended procedure in the vast majority of cases, irrespective of their clinical relevance. The presence of a major or moderate IF did not significantly impact 1-year mortality.


Assuntos
Doenças Assintomáticas/epidemiologia , Procedimentos Cirúrgicos Cardíacos/instrumentação , Achados Incidentais , Insuficiência da Valva Mitral/cirurgia , Simpatectomia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Prevalência , Instrumentos Cirúrgicos , Tomografia Computadorizada por Raios X
18.
J Cardiol ; 72(2): 149-154, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29478878

RESUMO

BACKGROUND AND AIMS: Significant left main (LM) stem disease is potentially life-threatening and mandates revascularization. This study aimed to assess how patients rate the importance of particular features of coronary artery bypass grafting (CABG) and percutaneous coronary intervention (PCI), how this determines their preference for a particular treatment strategy, and whether particular personality characteristics influence this preference. METHODS AND RESULTS: In total, 1145 patients who visited the outpatient clinic of the Erasmus Medical Center for stable coronary artery disease were asked to complete a case vignette-questionnaire on a hypothetical significant LM stenosis amenable to PCI or CABG. To assess the individual's personality disposition and general distress level, each patient had to complete a set of 3 standardized, validated questionnaires with satisfactory psychometric properties. Overall 89% of patients preferred PCI to CABG. PCI was the preferred strategy despite a higher risk for repeat revascularization and need for more medication. Remarkably, the fact that a risk for repeat revascularization is more common in the PCI group is less important for the patients who opt for PCI. Risk for stroke and bleeding were the most important arguments to opt for PCI over CABG. Type D personality, depression, and anxiety were all associated with a relatively higher preference for CABG as revascularization strategy. CONCLUSION: Overall, when given the choice patients seem to have a clear preference for PCI over CABG and consider stroke and bleeding important procedure-related complications. Patients with Type D personality, depression, or anxiety favor CABG.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/cirurgia , Preferência do Paciente , Intervenção Coronária Percutânea , Adulto , Idoso , Idoso de 80 Anos ou mais , Ansiedade , Ponte de Artéria Coronária/efeitos adversos , Depressão , Feminino , Hemorragia/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Risco , Acidente Vascular Cerebral/etiologia , Inquéritos e Questionários , Resultado do Tratamento , Personalidade Tipo D
19.
J Am Heart Assoc ; 6(9)2017 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-28939719

RESUMO

BACKGROUND: Coronary artery perforation (CAP) is a potentially lethal complication of percutaneous coronary intervention. We report on the incidence, clinical characteristics, and management of iatrogenic coronary perforations based on an 11-year single-center experience. METHODS AND RESULTS: From February 9, 2005, through November 20, 2016, 150 CAP cases were identified from our percutaneous coronary intervention database of 21 212 procedures (0.71%). Mean age of CAP patients was 66±11 years, and 62.7% were male. Treated lesion type was B2/C in 94.6%, and 31.3% were chronic total occlusions. Nonworkhorse guidewires were applied in 74.3%. CAP types were Ellis type I in 2.9%, Ellis type II in 40.4%, Ellis type III in 54.8%, and Ellis type III cavity spilling in 1.9%. CAP treatment was conservative (including prolonged balloon inflation) in 73.3%. Covered stents, coiling, and fat embolization were used in 24.0%, 0.7%, and 2.0%, respectively. Pericardiocentesis for tamponade was required for 72 patients (48.0%), of whom 28 were initially unrecognized. Twelve patients (12.7%) required emergency cardiac surgery to alleviate tamponade. Periprocedural myocardial infarction occurred in 34.0%, and in-hospital all-cause mortality was 8.0%. All-cause mortality accrued to 10.7% at 30 days and 17.8% at 1 year. CONCLUSIONS: CAP is a rare complication of percutaneous coronary intervention, but morbidity and mortality are considerable. Early recognition and adequate management are of paramount importance.


Assuntos
Angioplastia Coronária com Balão , Vasos Coronários/lesões , Embolização Terapêutica , Traumatismos Cardíacos/terapia , Intervenção Coronária Percutânea/efeitos adversos , Pericardiocentese , Lesões do Sistema Vascular/terapia , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/mortalidade , Tamponamento Cardíaco/diagnóstico por imagem , Tamponamento Cardíaco/mortalidade , Tamponamento Cardíaco/terapia , Vasos Coronários/diagnóstico por imagem , Bases de Dados Factuais , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/mortalidade , Feminino , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/mortalidade , Mortalidade Hospitalar , Humanos , Doença Iatrogênica , Incidência , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/mortalidade , Pericardiocentese/efeitos adversos , Pericardiocentese/mortalidade , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/mortalidade
20.
Eur Heart J Cardiovasc Imaging ; 18(6): 648-653, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28369281

RESUMO

AIMS: Paravalvular aortic leakage (PVL) after transcatheter aortic valve implantation (TAVI) is a complication with potentially severe consequences. The relation between native aortic root calcium burden, stent frame eccentricity and PVL was not studied before. METHODS AND RESULTS: Two-hundred-and-twenty-three consecutive patients with severe aortic stenosis who underwent TAVI with a Medtronic CoreValve System© and who had available pre-discharge transthoracic echocardiography were studied. Echocardiographic stent inflow frame eccentricity was defined as major-minor diameter in a short-axis view >2 mm. PVL was scored according to the updated Valve Academic Research Consortium (VARC-2) recommendations. In a subgroup of 162 (73%) patients, the calcium Agatston score was available. Stent frame eccentricity was seen in 77 (35%) of patients. The correlation between the Agatston score and stent frame eccentricity was significant (ρ = 0.241, P = 0.003). Paravalvular leakage was absent in 91 cases (41%), mild in 67 (30%), moderate in 51 (23%), and severe in 14 (6%) cases. The correlation between stent frame eccentricity and PVL severity was significant (ρ = 0.525, P < 0.0001). There was a relation between particular eccentric stent frame shapes and the site of PVL. CONCLUSION: Calcification of the aortic annulus is associated with a subsequent eccentric shape of the CoreValve prosthesis. This eccentric shape results in more PVL, with the localization of PVL related to the shape of stent frame eccentricity.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Calcinose/diagnóstico por imagem , Ecocardiografia Doppler em Cores/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/terapia , Estenose da Valva Aórtica/mortalidade , Calcinose/cirurgia , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Stents , Taxa de Sobrevida , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA