Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 179
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38972630

RESUMO

OBJECTIVE: Challenging infrarenal aortic neck characteristics have been associated with increased risk of a type Ia endoleak after endovascular aneurysm repair (EVAR). Short apposition (< 10 mm circumferential shortest apposition length [SAL]) on the first post-operative computerised tomography angiography (CTA) has been associated with type Ia endoleak. Therefore, this study aimed to develop a model to predict post-operative SAL in patients with an abdominal aortic aneurysm based on the pre-operative shape. METHODS: A statistical shape model was developed to obtain principal component scores. The dataset comprised patients treated with standard EVAR without complications (n = 93) enriched with patients with a late type Ia endoleak (n = 54). The infrarenal SAL was obtained from the first post-operative CTA and subsequently binarised (< 10 mm and ≥ 10 mm). The principal component scores that were statistically different between the SAL groups were used as input for five classification models, and evaluated by means of leave one out cross validation. Area under the receiver operating characteristics curves (AUC), accuracy, sensitivity, and specificity were determined for each classification model. RESULTS: Of the 147 patients, 24 patients had an infrarenal SAL < 10 mm and 123 patients had a SAL ≥ 10 mm. The gradient boosting model resulted in the highest AUC of 0.77. Using this model, 114 (78.0%) patients were correctly classified; sensitivity (< 10 mm apposition was correctly predicted) and specificity (≥ 10 mm apposition was correctly predicted) were 0.70 and 0.79, and were based on a threshold of 0.21, respectively. CONCLUSION: A model was developed to predict which patients undergoing EVAR will achieve sufficient graft apposition (≥ 10 mm) in the infrarenal aortic neck based on a statistical shape model of pre-operative CTA data. This model can help vascular specialists during the planning phase to accurately identify patients who are unlikely to achieve sufficient apposition after standard EVAR.

2.
Ann Vasc Surg ; 106: 80-89, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38579908

RESUMO

BACKGROUND: The study aims to describe midterm outcomes following treatment of infrarenal abdominal aortic aneurysms (AAAs) with short necks by endosutured aneurysm repair using the Heli-FX EndoAnchor system. METHODS: This is a retrospective study of prospectively collected data from 9 vascular surgery departments between June 2010 and December 2019, including treated AAAs with neck lengths ≤10 mm. The decision for the use of EndoAnchors was made by the treating surgeon or multidisciplinary aortic committee according to each center's practice. There were 2 Groups further assessed according to neck length, A (≥4 and <7 mm) and B (≥7 and ≤10 mm). The main outcomes analyzed were technical success, freedom from type Ia endoleaks (TIaELs), sac size increase, all-cause and aneurysm-related mortality. RESULTS: Seventy-six patients were included in the study, 17 fell into Group A and 59 into Group B. Median follow-up for the cohort was 40.5 (interquartile range 12-61) months. A median of 6 (interquartile range 3) EndoAnchors were deployed in each subject. Technical success was 86.8% for the total group, 82.4% and 88.1% (P = 0.534) for Groups A and B respectively. Six out of 10 (60%) of TIaELs at the completion angiographies showed spontaneous resolution. Cumulative freedom from TIaEL at 3 and 5 years for the total group was 89% and 84% respectively; this was 93% and 74% for Group A and 88% at both intervals in Group B (P = 0.545). In total, there were 7 (9.2%) patients presenting with TIaELs over the entire study period. Two (11.8%) in Group A and 5 (8.5%) in Group B (P = 0.679). There were more patients with sac regression in Group B (Group A = 6-35.3% vs. Group B = 34-57.6%, P = 0.230) with no statistical significance. All-cause mortality was 19 (25%) patients, with no difference (4-23.5% vs. 15-25.4%, P = 0.874) between groups; whereas aneurysm-related mortality occurred in 1 patient from Group A and 3 from Group B. CONCLUSIONS: This study demonstrates reasonable outcomes for patients with short-necked AAAs treated by endosutured aneurysm repair in terms of TIaELs up to 5-year follow-up. EndoAnchor use should be judiciously evaluated in short necks and may be a reasonable option when anatomical constraints are encountered, mainly for those with 7-10 mm neck lengths. Shorter neck length aspects, as indicated by the results from Group A, may be an alternative when no other options are available or feasible.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38670221

RESUMO

OBJECTIVE: The Gore Excluder Conformable Endoprosthesis (CEXC) is designed to treat challenging infrarenal anatomy because of its active angulation control, repositionability, and enhanced conformability. This study evaluated 30 day and one year position and apposition of the CEXC in the infrarenal neck. METHODS: Patients treated with the CEXC between 2018 and 2022 with an available 30 day computed tomography angiogram (CTA) were selected from four hospitals in a prospective registry. Endograft apposition (shortest apposition length [SAL]) and position (shortest fabric distance [SFD]) were assessed on the 30 day and one year CTAs. Maximum infrarenal aortic curvature was compared between the pre- and post-operative CTAs to evaluate conformability of the CEXC. RESULTS: There were 87 patients with a 30 day CTA, and for 56 of these patients the one year CTA was available. Median (interquartile range [IQR]) pre-operative neck length was 22 mm (IQR 15, 32) and infrarenal angulation was 52° (IQR 31, 72). Median SAL was 21.2 mm (IQR 14.0, 29.3) at 30 days for all included patients. The SAL in 13 patients (15%) was < 10 mm at 30 days, and one patient had a SAL of 0 mm and a type Ia endoleak. There was no significant difference in SAL between patients within and outside instructions for use. The SAL significantly increased by 1.1 mm (IQR -2.3, 4.7; p = .042) at one year. The SAL decreased in seven patients (13%), increased in 13 patients (23%), and remained stable in 36 patients (64%). Median SFD was 2.0 mm (IQR 0.5, 3.6) at 30 days, which slightly increased by 0.3 mm (IQR -0.5, 1.8; p = .019) at one year. One patient showed migration (SFD increase ≥ 5 mm). Median endograft tilt was 15.8° (IQR 9.7, 21.4). Pre-operative maximum infrarenal curvature was 36 m-1 (IQR 26, 56) and did not significantly change thereafter. CONCLUSION: In most patients, the CEXC was implanted close to the renal arteries, and sufficient (≥ 10 mm) post-operative apposition was achieved at 30 days, which slightly increased at one year. Post-operative endograft tilt was relatively low, and aortic geometry remained unchanged after implantation of the CEXC, probably due to its high conformability.

4.
Eur J Vasc Endovasc Surg ; 67(6): 935-947, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38552837

RESUMO

OBJECTIVE: This scoping review summarises health literacy and disease knowledge in patients with abdominal aortic aneurysm (AAA) or peripheral arterial disease (PAD) and the influencing factors. DATA SOURCES: A systematic search was conducted in PubMed, Embase, PsychINFO, and CINAHL covering the period January 2012 to October 2022. REVIEW METHODS: This scoping review was undertaken in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR). Inclusion criteria encompassed studies addressing health literacy, knowledge, perception, or awareness in patients with AAA or PAD. Two authors independently reviewed abstracts and full texts, resolving any discrepancies through discussion or by consulting a third author for consensus. All article types were included except letters, editorials, study protocols, reviews, and guidelines. No language restrictions were applied. Primary outcomes were health literacy and disease knowledge. Secondary outcomes were factors that could influence this. Quality assessment was done using the Mixed Methods Appraisal Tool (MMAT). RESULTS: The review included 32 articles involving a total of 5 268 patients. Four articles reported health literacy and the rest disease knowledge. Ten studies (31%) met all quality criteria. Twenty studies were quantitative, eight were qualitative, and four were mixed methods studies. The review revealed inadequate health literacy in the majority of patients, and disease knowledge was relatively low among patients with AAA and PAD, with disparities in measures and assessment tools across studies. Factors influencing health literacy and disease knowledge included socioeconomic status, education, income, and employment. CONCLUSION: This scoping review revealed low health literacy and low disease knowledge in patients with AAA and PAD. Standardised health literacy assessment may contribute to improve communication strategies and decision aids to enhance patients' understanding and engagement in healthcare decisions, however further research is needed to prove its merits.


Assuntos
Aneurisma da Aorta Abdominal , Conhecimentos, Atitudes e Prática em Saúde , Letramento em Saúde , Doença Arterial Periférica , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Doença Arterial Periférica/diagnóstico , Educação de Pacientes como Assunto
5.
J Clin Med ; 13(6)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38542032

RESUMO

Background: Endovascular techniques have gained preference over peripheral arterial bypass surgery due to their minimally invasive nature; however, endovascular treatments often show limited efficacy in arterial segments with a high atherosclerotic load. The use of atherectomy devices enables the removal of calcified plaque material and may promote arterial wall remodeling. This study assessed the technical success, safety, and feasibility of the BYCROSS® atherectomy device in femoropopliteal lesions. Methods: This single-center, retrospective cohort study analyzed elective patients undergoing BYCROSS® atherectomy for chronic peripheral arterial disease from March 2022 to May 2023. Patient data, procedural details, and outcomes were retrospectively collected from electronic patient records. The primary performance endpoints of this study were technical success, complications, and patency rates. Primary safety endpoints included 30-day and short-term major adverse limb events (MALEs), major adverse cardiovascular events (MACEs), and mortality rate. Results: The study included 19 patients (median age, 71 years; 63% male) with Fontaine class IIb (26%), III (21%), or IV (53%). The BYCROSS® atherectomy device was used to treat 22 limbs in the femoropopliteal tract, of which 11 lesions (50%) were occlusions and 11 were stenoses, with a median length of 24 cm (interquartile range: 17-38). Technical success was achieved in all cases: 4.5% required atherectomy only, 50% required additional balloon angioplasties, 41% required balloon angioplasties and stenting, and 4.5% required segments only stenting. Additional treatment of below-the-knee arteries was performed in 12 patients. Procedurally related complications (not limited to the use of the BYCROSS® device) occurred in 23% of limbs, including distal embolization and laceration. At 30 days, mortality was 5%, the MACE rate was 11%, and the MALE rate was 0%. The observed mortality rate was not directly related to the procedure. Patency (<50% restenosis at duplex ultrasound) was 83% at 30 days. Conclusions: The use of the BYCROSS® atherectomy device for the treatment of femoropopliteal lesions appears to be safe and feasible, with high technical success and low MALE and MACE rates in a challenging population with long-segment femoropopliteal lesions. Long-term follow-up in larger patient series is needed to confirm these findings and to determine the durability of this technique.

6.
Bone Jt Open ; 5(1): 46-52, 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38240277

RESUMO

Aims: Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery. Methods: A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group. Results: A total of 15 patients were treated with 3D surgical planning in which 83 screws were placed by using drilling guides. The median deviation of the achieved screw trajectory from the planned trajectory was 3.4° (interquartile range (IQR) 2.5 to 5.4) and the difference in entry points (i.e. plate position) was 3.0 mm (IQR 2.0 to 5.5) compared to the 3D preoperative planning. The length of 72 screws (86.7%) were according to the planning. Compared to the historical cohort, 3D-guided surgery showed an improved surgical reduction in terms of median gap (3.1 vs 4.7 mm; p = 0.126) and step-off (2.9 vs 4.0 mm; p = 0.026). Conclusion: The use of 3D surgical planning including drilling guides was feasible, and facilitated accurate screw directions, screw lengths, and plate positioning. Moreover, the personalized approach improved fracture reduction as compared to a historical cohort.

7.
Eur J Trauma Emerg Surg ; 50(1): 37-47, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38261077

RESUMO

PURPOSE: There is a debate whether corrective osteotomies of the distal radius should be performed using a 3D work-up with pre-contoured conventional implants (i.e., of-the-shelf) or patient-specific implants (i.e., custom-made). This study aims to assess the postoperative accuracy of 3D-assisted correction osteotomy of the distal radius using either implant. METHODS: Twenty corrective osteotomies of the distal radius were planned using 3D technologies and performed on Thiel embalmed human cadavers. Our workflow consisted of virtual surgical planning and 3D printed guides for osteotomy and repositioning. Subsequently, left radii were fixated with patient-specific implants, and right radii were fixated with pre-contoured conventional implants. The accuracy of the corrections was assessed through measurement of rotation, dorsal and radial angulation and translations with postoperative CT scans in comparison to their preoperative virtual plan. RESULTS: Twenty corrective osteotomies were executed according to their plan. The median differences between the preoperative plan and postoperative results were 2.6° (IQR: 1.6-3.9°) for rotation, 1.4° (IQR: 0.6-2.9°) for dorsal angulation, 4.7° (IQR: 2.9-5.7°) for radial angulation, and 2.4 mm (IQR: 1.3-2.9 mm) for translation of the distal radius, thus sufficient for application in clinical practice. There was no significant difference in accuracy of correction when comparing pre-contoured conventional implants with patient-specific implants. CONCLUSION: 3D-assisted corrective osteotomy of the distal radius with either pre-contoured conventional implants or patient-specific implants results in accurate corrections. The choice of implant type should not solely depend on accuracy of the correction, but also be based on other considerations like the availability of resources and the preoperative assessment of implant fitting.


Assuntos
Fraturas Mal-Unidas , Fraturas do Rádio , Cirurgia Assistida por Computador , Humanos , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Cirurgia Assistida por Computador/métodos , Fraturas Mal-Unidas/cirurgia , Osteotomia/métodos
8.
Eur J Trauma Emerg Surg ; 50(1): 11-19, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37391531

RESUMO

PURPOSE: A substantial proportion of conventional tibial plateau plates have a poor fit, which may result in suboptimal fracture reduction due to applied -uncontrolled- compression on the bone. This study aimed to assess whether patient-specific osteosyntheses could facilitate proper fracture reduction in medial tibial plateau fractures. METHODS: In three Thiel embalmed human cadavers, a total of six tibial plateau fractures (three Schatzker 4, and three Schatzker 6) were created and CT scans were made. A 3D surgical plan was created and a patient-specific implant was designed and fabricated for each fracture. Drilling guides that fitted on top of the customized plates were designed and 3D printed in order to assist the surgeon in positioning the plate and steering the screws in the preplanned direction. After surgery, a postoperative CT scan was obtained and outcome was compared with the preoperative planning in terms of articular reduction, plate positioning, and screw direction. RESULTS: A total of six patient-specific implants including 41 screws were used to operate six tibial plateau fractures. Three fractures were treated with single plating, and three fractures with dual plating. The median intra-articular gap was reduced from 6.0 (IQR 4.5-9.5) to 0.9 mm (IQR 0.2-1.4), whereas the median step-off was reduced from 4.8 (IQR 4.1-5.3) to 1.3 mm (IQR 0.9-1.5). The median Euclidean distance between the centre of gravity of the planned and actual implant was 3.0 mm (IQR: 2.8-3.7). The lengths of the screws were according to the predetermined plan. None of the screws led to screw penetration. The median difference between the planned and actual screw direction was 3.3° (IQR: 2.5-5.1). CONCLUSION: This feasibility study described the development and implementation of a patient-specific workflow for medial tibial plateau fracture surgery that facilitates proper fracture reduction, tibial alignment and accurately placed screws by using custom-made osteosynthesis plates with drilling guides.


Assuntos
Fraturas da Tíbia , Fraturas do Planalto Tibial , Humanos , Fixação Interna de Fraturas , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Parafusos Ósseos , Placas Ósseas , Impressão Tridimensional
9.
Ann Vasc Surg ; 99: 166-174, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37924865

RESUMO

BACKGROUND: Patients with chronic limb threatening ischemia (CLTI) are at high risk for amputation and other cardiovascular adverse events. Nutrition-related symptoms and malnutrition are common in the CLTI population, and lead to worse clinical outcomes. Understanding of the factors influencing nutritional intake is required to determine whether optimization of nutritional intake in this population requires interventions. Therefore, this study aimed to describe perceptions and experiences on nutrition of patients with CLTI, and to identify perceived barriers and facilitators influencing their nutritional intake. METHODS: In this phenomenological qualitative study, individual semi-structured, face-to-face interviews were conducted with patients with CLTI who lived independently. Interviews were transcribed verbatim, and reflexive thematic analysis was performed. RESULTS: Twelve participants were interviewed. Five themes were generated: (1) lack of nutritional risk perception, (2) role of nutrition for health, functioning, and surviving, (3) multiple factors influencing nutritional intake, (4) limited nutritional advice, and (5) no intention to change current nutritional intake. CONCLUSIONS: Patients with CLTI perceive nutritional intake as a necessity to survive and function. Patients express limited risk perception regarding adequate nutritional intake and undernutrition. Nutritional intake is mainly based on non-health-related factors, as habits and taste, and multiple barriers hinder nutritional intake. Patients received no or only limited nutritional advice. Together this leads to an expressed lack of intention to change nutritional intake. Findings of this study stress the urgency for patient-centered nutritional support, to increase nutrition-related knowledge and motivation, to prevent or treat undernutrition, and may improve clinical outcomes in patients with CLTI.


Assuntos
Desnutrição , Doença Arterial Periférica , Humanos , Isquemia Crônica Crítica de Membro , Isquemia , Resultado do Tratamento , Desnutrição/diagnóstico , Estado Nutricional , Fatores de Risco , Salvamento de Membro , Estudos Retrospectivos
10.
J Clin Med ; 12(18)2023 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-37762994

RESUMO

BACKGROUND: Conventional measures of fracture displacement have low interobserver reliability. This study introduced a novel 3D method to measure tibial plateau fracture displacement and its impact on functional outcome. METHODS: A multicentre study was conducted on patients who had tibial plateau fracture surgery between 2003 and 2018. Eligible patients had a preoperative CT scan (slice thickness ≤ 1 mm) and received a Knee Injury and Osteoarthritis Outcome Score (KOOS) questionnaire. A total of 362 patients responded (57%), and assessment of initial and residual fracture displacement was performed via measurement using the 3D gap area (mm2). Patients were divided into four groups based on the 3D gap area size. Differences in functional outcome between these groups were assessed using analysis of variance (ANOVA). Multiple linear regression was used to determine the association between fracture displacement and patient-reported outcome. RESULTS: Functional outcome appeared significantly worse when initial or residual fracture displacement increased. Multivariate linear regression showed that initial 3D gap area (per 100 mm2) was significantly negatively associated with all KOOS subscales: symptoms (-0.9, p < 0.001), pain (-0.0, p < 0.001), ADL (-0.8, p = 0.002), sport (-1.4, p < 0.001), and QoL (-1.1, p < 0.001). In addition, residual gap area was significantly negatively associated with the subscales symptoms (-2.2, p = 0.011), ADL (-2.2, p = 0.014), sport (-2.6, p = 0.033), and QoL (-2.4, p = 0.023). CONCLUSION: A novel 3D measurement method was applied to quantify initial and residual displacement. This is the first study which can reliably classify the degree of displacement and indicates that increasing displacement results in poorer patient-reported functional outcomes.

11.
BMJ Open ; 13(8): e072875, 2023 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-37643848

RESUMO

INTRODUCTION: Acute mesenteric ischaemia (AMI) is a life-threatening condition with short-term mortality of up to 80%. The diagnosis of AMI has remained troublesome due to the non-specific clinical presentation, symptoms and laboratory findings. Early unambiguous diagnosis of AMI is critical to prevent progression from reversible to irreversible transmural intestinal damage, thereby decreasing morbidity and improving survival. The present study aims to validate a panel of plasma biomarkers and investigate volatile organic compound (VOC) profiles in exhaled air as a tool to timely and accurately diagnose AMI. METHODS AND ANALYSIS: In this international multicentre prospective observational study, 120 patients (>18 years of age) will be recruited with clinical suspicion of AMI. Clinical suspicion is based on: (1) clinical manifestation, (2) physical examination, (3) laboratory measurements and (4) the physician's consideration to perform a CT scan. The patient's characteristics, repetitive blood samples and exhaled air will be prospectively collected. Plasma levels of mucosal damage markers intestinal fatty acid-binding protein and villin-1, as well as transmural damage marker smooth muscle protein 22-alpha, will be assessed by ELISA. Analysis of VOCs in exhaled air will be performed by gas chromatography time-of-flight mass spectrometry. Diagnosis of AMI will be based on CT, endovascular and surgical reports, clinical findings, and (if applicable) verified by histopathological examination. ETHICS AND DISSEMINATION: The study protocol was approved by the Medical Research Ethics Committee (METC) of Maastricht University Medical Centre+ and Maastricht University (METC azM/UM), the Netherlands (METC19-010) and the Ethics Committee Research UZ/KU Leuven, Belgium (S63500). Executive boards and local METCs of other Dutch participating centres Gelre Ziekenhuizen (Apeldoorn), Medisch Spectrum Twente (Enschede), and University Medical Centre Groningen have granted permission to carry out this study. Study results will be disseminated via open-access peer-reviewed scientific journals and national/international conferences. TRIAL REGISTRATION NUMBER: NCT05194527.


Assuntos
Isquemia Mesentérica , Compostos Orgânicos Voláteis , Humanos , Isquemia Mesentérica/diagnóstico , Centros Médicos Acadêmicos , Biomarcadores , Comitês de Ética em Pesquisa , Estudos Observacionais como Assunto , Estudos Multicêntricos como Assunto
12.
J Clin Med ; 12(11)2023 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-37297962

RESUMO

Knowledge about anatomical shape variations in the pelvis is mandatory for selection, fitting, positioning, and fixation in pelvic surgery. The current knowledge on pelvic shape variation mostly relies on point-to-point measurements on 2D X-ray images and computed tomography (CT) slices. Three-dimensional region-specific assessments of pelvic morphology are scarce. Our aim was to develop a statistical shape model of the hemipelvis to assess anatomical shape variations in the hemipelvis. CT scans of 200 patients (100 male and 100 female) were used to obtain segmentations. An iterative closest point algorithm was performed to register these 3D segmentations, so a principal component analysis (PCA) could be performed, and a statistical shape model (SSM) of the hemipelvis was developed. The first 15 principal components (PCs) described 90% of the total shape variation, and the reconstruction ability of this SSM resulted in a root mean square error of 1.58 (95% CI: 1.53-1.63) mm. In summary, an SSM of the hemipelvis was developed, which describes the shape variations in a Caucasian population and is able to reconstruct an aberrant hemipelvis. Principal component analyses demonstrated that, in a general population, anatomical shape variations were mostly related to differences in the size of the pelvis (e.g., PC1 describes 68% of the total shape variation, which is attributed to size). Differences between the male and female pelvis were most pronounced in the iliac wing and pubic rami regions. These regions are often subject to injuries. Future clinical applications of our newly developed SSM may be relevant for SSM-based semi-automatic virtual reconstruction of a fractured hemipelvis as part of preoperative planning. Lastly, for companies, using our SSM might be interesting in order to assess which sizes of pelvic implants should be produced to provide proper-fitting implants for most of the population.

13.
J Bone Joint Surg Am ; 105(16): 1237-1245, 2023 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-37196070

RESUMO

BACKGROUND: Radiographic measurements of initial displacement of tibial plateau fractures and of postoperative reduction are used to determine treatment strategy and prognosis. We assessed the association between radiographic measurements and the risk of conversion to total knee arthroplasty (TKA) at the time of follow-up. METHODS: A total of 862 patients surgically treated for tibial plateau fractures between 2003 and 2018 were eligible for this multicenter cross-sectional study. Patients were approached for follow-up, and 477 (55%) responded. The initial gap and step-off were measured on the preoperative computed tomography (CT) scans of the responders. Condylar widening, residual incongruity, and coronal and sagittal alignment were measured on postoperative radiographs. Critical cutoff values for gap and step-off were determined using receiver operating characteristic curves. Postoperative reduction measurements were categorized as adequate or inadequate on the basis of cutoff values in international guidelines. Multivariable analysis was performed to assess the association between each radiographic measurement and conversion to TKA. RESULTS: Sixty-seven (14%) of the patients had conversion to TKA after a mean follow-up of 6.5 ± 4.1 years. Assessment of the preoperative CT scans revealed that a gap of >8.5 mm (hazard ratio [HR] = 2.6, p < 0.001) and step-off of >6.0 mm (HR = 3.0, p < 0.001) were independently associated with conversion to TKA. Assessment of the postoperative radiographs demonstrated that residual incongruity of 2 to 4 mm was not associated with increased risk of TKA compared with adequate fracture reduction of <2 mm (HR = 0.6, p = 0.176). Articular incongruity of >4 mm resulted in increased risk of TKA. Coronal (HR = 1.6, p = 0.05) and sagittal malalignment (HR = 3.7 p < 0.001) of the tibia were strongly associated with conversion to TKA. CONCLUSIONS: Substantial preoperative fracture displacement was a strong predictor of conversion to TKA. Postoperative gaps or step-offs of >4 mm as well as inadequate alignment of the tibia were strongly associated with an increased risk of TKA. LEVEL OF EVIDENCE: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia do Joelho , Fraturas da Tíbia , Fraturas do Planalto Tibial , Humanos , Artroplastia do Joelho/efeitos adversos , Estudos Transversais , Resultado do Tratamento , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/complicações , Tíbia/cirurgia , Estudos Retrospectivos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia
14.
J Vasc Surg ; 78(4): 995-1002, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37257670

RESUMO

OBJECTIVE: Carotid endarterectomy (CEA) aims to reduce the risk of stroke in patients with atherosclerotic carotid disease. Preoperative risk assessments that predict complications are needed to optimize the care in this patient group. The current approach, namely relying solely on symptomatology and degree of stenosis, is outdated and calls for innovation. The Agatston calcium score was applied in several vascular specialties to assess cardiovascular risk profile but has been little studied in carotid surgery. It is hypothesized that a higher calcium burden at initial presentation equates to a worse prognosis attributable to an increased cerebrovascular and cardiovascular risk profile. The aim was to investigate the association between preoperative ipsilateral calcium score and postoperative all-cause mortality in patients undergoing CEA. METHODS: This single-center retrospective cohort study included 89 patients who underwent CEA at a tertiary referral center between 2010 and 2018. Preoperative calcium scores were measured on contrast-enhanced computed tomography images with patient-specific Hounsfield thresholds at the level of the carotid bifurcation. The association between these calcium scores and all-cause mortality was analyzed using multivariable adjusted Cox proportional hazard analysis. RESULTS: Cox proportional hazard analysis demonstrated a significant association between preoperative ipsilateral carotid calcium score and all-cause mortality (hazard ratio, 1.10; 95% confidence interval, 1.03-1.16; P = .003). After adjusting for age, preoperative estimated glomerular filtration rate, and diabetes mellitus, a significant association remained (hazard ratio, 1.07; 95% confidence interval, 1.00-1.15; P = .05). CONCLUSIONS: A higher calcium burden was predictive of worse outcome, which might be explained by an overall poorer health status. These results highlight the potential of calcium measurements in combination with other traditional risk factors, for preoperative risk assessment and thus for improved patient education and care.


Assuntos
Estenose das Carótidas , Endarterectomia das Carótidas , Acidente Vascular Cerebral , Humanos , Endarterectomia das Carótidas/efeitos adversos , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Cálcio , Angiografia por Tomografia Computadorizada/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Acidente Vascular Cerebral/etiologia , Fatores de Risco , Medição de Risco
15.
J Clin Med ; 12(8)2023 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-37109113

RESUMO

Near-infrared spectroscopy (NIRS) is a non-invasive technique for measuring regional tissue haemoglobin (Hb) concentrations and oxygen saturation (rSO2). It may be used to monitor cerebral perfusion and oxygenation in patients at risk of cerebral ischemia or hypoxia, for example, during cardiothoracic or carotid surgery. However, extracerebral tissue (mainly scalp and skull tissue) influences NIRS measurements, and the extent of this influence is not clear. Thus, before more widespread use of NIRS as an intraoperative monitoring modality is warranted, this issue needs to be better understood. We therefore conducted a systematic review of published in vivo studies of the influence of extracerebral tissue on NIRS measurements in the adult population. Studies that used reference techniques for the perfusion of the intra- and extracerebral tissues or that selectively altered the intra- or extracerebral perfusion were included. Thirty-four articles met the inclusion criteria and were of sufficient quality. In 14 articles, Hb concentrations were compared directly with measurements from reference techniques, using correlation coefficients. When the intracerebral perfusion was altered, the correlations between Hb concentrations and intracerebral reference technique measurements ranged between |r| = 0.45-0.88. When the extracerebral perfusion was altered, correlations between Hb concentrations and extracerebral reference technique measurements ranged between |r| = 0.22-0.93. In studies without selective perfusion modification, correlations of Hb with intra- and extracerebral reference technique measurements were generally lower (|r| < 0.52). Five articles studied rSO2. There were varying correlations of rSO2 with both intra- and extracerebral reference technique measurements (intracerebral: |r| = 0.18-0.77, extracerebral: |r| = 0.13-0.81). Regarding study quality, details on the domains, participant selection and flow and timing were often unclear. We conclude that extracerebral tissue indeed influences NIRS measurements, although the evidence (i.e., correlation) for this influence varies considerably across the assessed studies. These results are strongly affected by the study protocols and analysis techniques used. Studies employing multiple protocols and reference techniques for both intra- and extracerebral tissues are therefore needed. To quantitatively compare NIRS with intra- and extracerebral reference techniques, we recommend applying a complete regression analysis. The current uncertainty regarding the influence of extracerebral tissue remains a hurdle in the clinical implementation of NIRS for intraoperative monitoring. The protocol was pre-registered in PROSPERO (CRD42020199053).

16.
J Vasc Surg Venous Lymphat Disord ; 11(4): 843-853.e2, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36893883

RESUMO

BACKGROUND: Patients with severe acute low iliofemoral deep vein thrombosis (DVT), such as phlegmasia cerulea dolens, benefit from catheter-directed thrombolysis (CDT). This meta-analysis investigated the effectiveness and safety of adjuvant percutaneous mechanical thrombectomy (PMT) during CDT compared with CDT alone in the treatment of acute iliofemoral DVT. METHODS: A meta-analysis was performed in accordance with the PRISMA guidelines. Medline, Embase, the Cochrane Library, China National Knowledge Internet, and Wanfang data were searched for studies on the management of acute iliofemoral DVT by means of CDT or CDT with adjuvant PMT. Randomized, controlled trials and nonrandomized studies were included. The primary outcomes were venous patency rate, major bleeding complications, and post-thrombotic syndrome occurrence within 2 years of the procedure. The secondary outcomes were thrombolytic time and volume, as well as the rates of thigh detumescence and iliac vein stenting. RESULTS: The meta-analysis included 20 eligible studies with a total of 1686 patients. The rates of venous patency (mean difference, 10.11; 95% confidence interval [CI], 5.59-14.62) and thigh detumescence (mean difference, 3.64; 95% CI, 1.10-6.18) of the adjuvant PMT group were higher than those of the CDT alone group. Compared with CDT alone, the adjuvant PMT group experienced fewer incidences of major bleeding complications (odds ratio, 0.45; 95% CI, 0.26-0.77) and occurrences of post-thrombotic syndrome within 2 years of the procedure (odds ratio, 0.55; 95% CI, 0.33-0.92). Furthermore, the duration of thrombolytic therapy was shorter, and the total dose of administered thrombolytics was lower with adjuvant PMT. CONCLUSIONS: Adjuvant PMT during CDT is associated with improved clinical outcomes and a lower incidence of major bleeding complications. The studies investigated were, however, single-center cohort studies, and future randomized controlled trials are needed to substantiate these findings.


Assuntos
Trombólise Mecânica , Síndrome Pós-Trombótica , Trombose Venosa , Humanos , Resultado do Tratamento , Trombectomia/efeitos adversos , Trombectomia/métodos , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/terapia , Trombose Venosa/complicações , Terapia Trombolítica/efeitos adversos , Terapia Trombolítica/métodos , Fibrinolíticos , Síndrome Pós-Trombótica/diagnóstico por imagem , Síndrome Pós-Trombótica/etiologia , Síndrome Pós-Trombótica/terapia , Catéteres/efeitos adversos , Veia Ilíaca/diagnóstico por imagem , Hemorragia/complicações , Estudos Retrospectivos , Trombólise Mecânica/efeitos adversos
17.
Int J Cardiol ; 375: 94-97, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36577485

RESUMO

BACKGROUND: Patients with peripheral artery disease (PAD) have an increased risk of abdominal aortic aneurysms (AAA), but it remains unclear whether practitioners are screening patients for AAA as part of routine PAD management. METHODS: The Patient-centered Outcomes Related to Treatment Practices in Peripheral Arterial Disease (PORTRAIT) Registry is an international prospective registry of patients with new or worsening PAD symptoms presenting to 16 specialty centers in the United States, Netherlands, and Australia, from June 2011 to December 2015. Patients were stratified by AAA screening or AAA positivity. An adjusted median odds ratio was calculated for AAA screening rates across sites. RESULTS: Of the 1275 patients in the study, 871 (68%) were screened for AAA, with 53 (6.1%) having AAA. AAA screening rates did not differ significantly by country (p = 0.36), but there was a large variation across sites for documentation of AAA screening with an adjusted median odds ratio 12.0 (95% CI 4.7-93.1), with AAA screening rates ranging from 7% to 100% across vascular specialty centers. CONCLUSIONS: Among patients with PAD in a multicenter registry, over two-thirds were screened for AAA, with 6% having documented aneurysms. A large variation was seen across clinical sites, suggesting efforts are needed to increase awareness for guideline implementation and establish new benefit-risk evidence inclusive of high-risk populations such as patients with PAD.


Assuntos
Aneurisma da Aorta Abdominal , Pneumopatias , Doença Arterial Periférica , Humanos , Estados Unidos , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/epidemiologia , Fatores de Risco , Medição de Risco , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/epidemiologia , Programas de Rastreamento
18.
Eur J Trauma Emerg Surg ; 49(2): 867-874, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36264307

RESUMO

PURPOSE: Currently used classification systems and measurement methods are insufficient to assess fracture displacement. In this study, a novel 3D measure for fracture displacement is introduced and associated with risk on conversion to total knee arthroplasty (TKA). METHODS: A multicenter cross-sectional study was performed including 997 patients treated for a tibial plateau fracture between 2003 and 2018. All patients were contacted for follow-up and 534 (54%) responded. For all patients, the 3D gap area was determined in order to quantify the degree of initial fracture displacement. A cut-off value was determined using ROC curves. Multivariate analysis was performed to assess the association of 3D gap area with conversion to TKA. Subgroups with increasing levels of 3D gap area were identified, and Kaplan-Meier survival curves were plotted to assess survivorship of the knee free from conversion to TKA. RESULTS: A total of 58 (11%) patients underwent conversation to TKA. An initial 3D gap area ≥ 550 mm2 was independently associated with conversion to TKA (HR 8.4; p = 0.001). Four prognostic groups with different ranges of the 3D gap area were identified: excellent (0-150 mm2), good (151-550 mm2), moderate (551-1000 mm2), and poor (> 1000 mm2). Native knee survival at 10-years follow-up was 96%, 95%, 76%, and 59%, respectively, in the excellent, good, moderate, and poor group. CONCLUSION: A novel 3D measurement method was developed to quantify initial fracture displacement of tibial plateau fractures. 3D fracture assessment adds to current classification methods, identifies patients at risk for conversion to TKA at follow-up, and could be used for patient counselling about prognosis. LEVEL OF EVIDENCE: Prognostic Level III.


Assuntos
Artroplastia do Joelho , Fraturas da Tíbia , Fraturas do Planalto Tibial , Humanos , Seguimentos , Estudos Transversais , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Resultado do Tratamento
19.
Eur J Vasc Endovasc Surg ; 65(3): 359-368, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36336284

RESUMO

OBJECTIVE: It has been suggested that covered stents (CS) may lower restenosis rates compared with bare metal stents (BMS) after endovascular treatment of the common iliac artery. This trial aimed to provide additional evidence on the efficacy of CS vs. BMS in the common iliac artery. METHODS: This multicentre, randomised, single blind controlled superiority trial compared balloon expandable CS and balloon expandable BMS for advanced atherosclerotic lesions in the common iliac artery; this was defined as a stenosis > 3 cm in length or occlusion. The primary end point was freedom from binary restenosis after two years of follow up. The study was conducted according to the principles of the Declaration of Helsinki (version: October 2008) and registered with the Dutch Trial register (NTR3381). RESULTS: One hundred and seventy-four limbs were included between 2012 and 2019 with 87 limbs in each group. Six patients crossed over from the BMS group to the CS group but were analysed according to an intention to treat principle. Freedom from binary restenosis after two years of follow up was 84.7% (95% CI 76.7 - 92.7%) in the BMS group and 89.1% (95% CI 82.4 - 95.8%) in the CS group (p = .40). Freedom from occlusion was 95.0% (95% CI 90.3 - 95.7%) in the BMS group and 96.4% (95% CI 92.5 - 100%) in the CS group (p = .66). Freedom from target lesion revascularisation was 91.1% (95% CI 84.8 - 97.3%) and 95.2% (95% CI 90.7 -99.7%), respectively (p = .31). Technical success, complications, haemodynamic success, and clinical success were also comparable between both groups. Per-protocol analysis did not affect the outcomes of the study. CONCLUSION: No difference was found between balloon expandable CS and BMS for treating advanced atherosclerotic lesions of the common iliac artery.

20.
JMIR Perioper Med ; 5(1): e40815, 2022 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-36441586

RESUMO

BACKGROUND: Preoperative telemonitoring of vital signs, physical activity, and well-being might be able to optimize prehabilitation of the patient's physical and mental condition prior to surgery, support setting alarms during in-hospital monitoring, and allow personalization of the postoperative recovery process. OBJECTIVE: The primary aim of this study was to evaluate when and how long patients awaiting major abdominal surgery should be monitored to get reliable preoperative individual baseline values of heart rate (HR), daily step count, and patient-reported outcome measures (PROMs). The secondary aim was to describe the perioperative course of these measurements at home. METHODS: In this observational single-center cohort study, patients used a wearable sensor during waking hours and reported PROMs (pain, anxiety, fatigue, nausea) on a tablet twice a day. Intraclass correlation coefficients (ICCs) were used to evaluate the reliability of mean values on 2 specific preoperative days (the first day of telemonitoring and the day before hospital admission) and randomly selected preoperative periods compared to individual reference values. Mean values of HR, step count, and PROMs per day were visualized in a boxplot from 14 days before hospital admission until 30 days after surgery. RESULTS: A total of 16 patients were included in the data analyses. The ICCs of mean values on the first day of telemonitoring were 0.91 for HR, 0.71 for steps, and at least 0.86 for PROMs. The day before hospital admission showed reliability coefficients of 0.76 for HR, 0.71 for steps, and 0.92-0.99 for PROMs. ICC values of randomly selected measurement periods increased over the continuous period of time from 0.68 to 0.99 for HR and daily step counts. A lower bound of the 95% CI of at least 0.75 was determined after 3 days of measurements. The ICCs of randomly selected PROM measurements were 0.89-0.94. Visualization of mean values per day mainly showed variable preoperative daily step counts (median 2409, IQR 1735-4661 steps/day) and lower postoperative daily step counts (median 884, IQR 474-1605 steps/day). In addition, pain was visually reduced until 30 days after surgery at home. CONCLUSIONS: In this prospective pilot study, for patients awaiting major abdominal surgery, baseline values for HR and daily step count could be measured reliably by a wearable sensor worn for at least 3 consecutive days and PROMs during any preoperative day. No clear conclusions were drawn from the description of the perioperative course by showing mean values of HR, daily step count, and PROM values over time in the home situation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA