Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Biomech ; 161: 111833, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37845112

RESUMO

In surgical staff, low-back pain (LBP) is prevalent and prolonged trunk inclination is hypothesized to be one of its potential causes. The aim of this study was to evaluate the magnitude and duration of trunk inclination in the sagittal plane of surgical assistants during surgical procedures. The three-dimensional trunk orientation was measured in 91 surgical assistants across four medical facilities during surgical procedures using an inertial measurement unit on the thorax. Per participant, Exposure Variation Analysis was used to evaluate the percentage of the total time of trunk inclination (< -10° (backward inclination); -10-10° (upright posture); 10-20° (light inclination); 20-30° (moderate inclination); >30° (strong inclination)) taking into account posture duration (< 10 s; 10-60 s; 60-300 s; > 300 s). Participants reported their LBP history and perceived low-back load during the procedure via a questionnaire. Participants were in an upright posture for 75% [63-84%] (median [interquartile range]) of the total surgery time (average surgery time: 174 min). Trunk inclination was beyond 20° and 30° for 4.3% [2.1-8.7%] and 1.5% [0.5-3.2%] of the surgery time, respectively. In most of the participants, the duration of trunk inclination beyond 20° or 30° was less than 60 s. Questionnaire response rate was 81%. Persistent or repeated LBP was reported by 49% of respondents, and was unrelated to the exposure to inclined trunk postures. It is concluded that other factors than prolonged trunk inclination, for instance handling of loads or prolonged standing may be causally related to the reported LBP in the investigated population.


Assuntos
Dor Lombar , Postura , Humanos , Postura/fisiologia , Dor Lombar/etiologia , Tórax/fisiologia , Posição Ortostática , Amplitude de Movimento Articular/fisiologia
2.
Arch Orthop Trauma Surg ; 142(6): 1189-1196, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33956227

RESUMO

INTRODUCTION: Functional outcome and patients' daily-life activities after total knee arthroplasty are becoming more important with a younger and more active patient population. In addition to patient-reported outcome measures (PROMs), trunk-based accelerometry has shown to be a promising method for evaluating gait function after total knee arthroplasty. The aim of this study was to evaluate daily-life perceived walking abilities, gait behavior and gait quality before and 3 months after total knee arthroplasty, using PROMs and trunk-based accelerometry. MATERIALS AND METHODS: A cohort of 38 patients completed questionnaires including the Oxford Knee Score and modified Gait Efficacy Scale before and 3 months after primary unilateral total knee arthroplasty. At both time points, they wore a tri-axial accelerometer at the lower back for seven consecutive days and nights. Gait behavior was calculated using gait quantity and walking speed, and multiple gait quality parameters were calculated. RESULTS: Significant improvements were seen after 3 months in the Oxford Knee Score [median (interquartile range) 29 (10) vs 39 (8), p < 0.001] and modified Gait Efficacy Scale [median (interquartile range) 67 (24) vs 79 (25), p = 0.001]. No significant changes were observed in gait behavior (quantity and speed) or gait quality variables. CONCLUSIONS: In contrast to the significant improvements in patients' perception of their walking abilities and PROMs, patients did not show improvements in gait behavior and gait quality. This implies that after 3 months patients' perceived functional abilities after total knee arthroplasty do not necessarily represent their actual daily-life quantity and quality of gait, and that more focus is needed on postoperative rehabilitation to improve gait and functional behavior.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Artroplastia do Joelho/métodos , Marcha , Humanos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Inquéritos e Questionários , Caminhada
3.
Scand J Med Sci Sports ; 27(2): 177-187, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26773332

RESUMO

Connective tissue formation following muscle injury and remedial surgery may involve changes in the stiffness and configuration of the connective tissues linking adjacent muscles. We investigated changes in mechanical interaction of muscles by implanting either a tissue-integrating mesh (n = 8) or an adhesion barrier (n = 8) to respectively increase or decrease the intermuscular connectivity between soleus muscle (SO) and the lateral gastrocnemius and plantaris complex (LG+PL) of the rat. As a measure of mechanical interaction, changes in SO tendon forces and proximal-distal LG+PL force differences in response to lengthening LG+PL proximally were assessed 1 and 2 weeks post-surgery. The extent of mechanical interaction was doubled 1 week post-implantation of the tissue-integrating mesh compared to an unaffected compartment (n = 8), and was more than four times higher 2 weeks post-surgery. This was found only for maximally activated muscles, but not when passive. Implanting the adhesion barrier did not result in a reduction of the mechanical interaction between these muscles. Our findings indicate that the ratio of force transmitted via myofascial, rather than myotendinous pathways, can increase substantially when the connectivity between muscles is enhanced. This improves our understanding of the consequences of connective tissue formation at the muscle boundary on skeletal muscle function.


Assuntos
Tecido Conjuntivo/fisiopatologia , Fáscia/fisiopatologia , Extremidade Inferior , Músculo Esquelético/fisiopatologia , Tendões/fisiopatologia , Animais , Fenômenos Biomecânicos , Tecido Conjuntivo/fisiologia , Estimulação Elétrica , Fáscia/fisiologia , Masculino , Músculo Esquelético/fisiologia , Ratos , Ratos Wistar , Telas Cirúrgicas , Tendões/fisiologia , Nervo Tibial
4.
Knee Surg Sports Traumatol Arthrosc ; 10(4): 204-12, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12211185

RESUMO

We present the rationale and design of the DynaPort knee test. The test aims at measuring knee patients' functional abilities in an unobtrusive, user-friendly way. Test persons wear several belts around their trunk and legs. The belts contain accelerometers, the signals of which are stored in a recorder, embedded in one of the belts. The knee test consists of a set of 29 tasks related to activities of daily life ("test items"). Accelerometer signals are analyzed in terms of 30 "movement features" (accelerations, angles, durations, frequencies, and some dimensionless numbers). In data analysis, the beginning and end of each test item is marked by hand; otherwise, analysis is automatic. We compared 140 knee patients with 32 healthy controls and found 541 of the 29 x 30=870 test item x movement feature combinations differed significantly between the two groups. From these 541 combinations the DynaPort knee score is calculated by the weighted averages of movement features per item, then weighted averages of items per cluster (locomotion, rising and descending, transfers, lifting and moving objects), and finally the average of the clusters. In an initial study the test-retest reliability of the knee test proved high, and the test turned out to be sufficiently responsive (0.7 patients' standard deviations improvement after 24 months). However, it remains difficult to interpret the scores in more meaningful terms than merely "better" or "worse." Extensive reliability studies in the future will further assess the validity of the test and provide more insight into the meaning of the scores. The DynaPort knee test may thus become an important instrument for evaluating patients'functional abilities in knee-related clinical practice and research.


Assuntos
Atividades Cotidianas , Teste de Esforço/instrumentação , Joelho/fisiopatologia , Doenças Musculoesqueléticas/fisiopatologia , Idoso , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento/fisiologia , Doenças Musculoesqueléticas/reabilitação , Recuperação de Função Fisiológica/fisiologia , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA