Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 10(9): e29570, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38765076

RESUMO

Objectives: Distal radius malunion can result in pain and functional complaints. One of the functional problems that can affect daily life is impaired forearm rotation. The primary aim of this study was to investigate the effect of corrective osteotomy for distal radius malunion on forearm rotation at 12 months after surgery. We secondarily studied the effect on grip strength, radiological measurements, and patient-reported outcome measurements (PROMs). Patients and methods: This cohort study analysed prospectively collected data of adult patients with symptomatic distal radius malunion. All patients underwent corrective osteotomy for malunion and were followed for 1 year. We measured forearm rotation (pronation and supination) and grip strength and analysed radiographs. PROMs consisted of the Patient-Rated Hand/Wrist Evaluation (PRWHE) questionnaire, Visual Analogue Scale for pain, and satisfaction with hand function. Results: Preoperative total forearm rotation was 112° (SD: 34°), of which supination of 49° (SD: 25°) was more impaired than pronation of 63° (SD: 17°). Twelve months after surgery, an unpaired Student's t-test showed a significant improvement of total forearm rotation to 142° (SD: 17°) (p < 0.05). Pronation improved to 72° (SD: 10°), and supination to 69° (SD: 13°) (p < 0.05). Grip strength, PROMs, as well as inclination and volar tilt on radiographs improved significantly during the first year after surgery (p < 0.05). Conclusion: In patients with reduced forearm rotation due to distal radius malunion, corrective osteotomy is an effective treatment that significantly improves forearm rotation. In addition, this intervention improves grip strength, the PRWHE-score, pain, and satisfaction with hand function.

2.
Anal Chim Acta ; 1141: 221-229, 2021 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-33248656

RESUMO

Accurate measurement of naturally occurring radionuclides in blast furnace slag, a by-product of the steel industry, is required for compliance with building regulations where it is often used as an ingredient in cement. A matrix reference blast furnace slag material has been developed to support traceability in these measurements. Raw material provided by a commercial producer underwent stability and homogeneity testing, as well as characterisation of matrix constituents, to provide a final candidate reference material. The radionuclide content was then determined during a comparison exercise that included 23 laboratories from 14 countries. Participants determined the activity per unit mass for 226Ra, 232Th and 40K using a range of techniques. The consensus values obtained from the power-moderated mean of the reported participant results were used as indicative activity per unit mass values for the three radionuclides: A0(226Ra) = 106.3 (34) Bq·kg-1, A0(232Th) = 130.0 (48) Bq·kg-1 and A0(40K) = 161 (11) Bq·kg-1 (where the number in parentheses is the numerical value of the combined standard uncertainty referred to the corresponding last digits of the quoted result). This exercise helps to address the current shortage of NORM industry reference materials, putting in place infrastructure for production of further reference materials.

3.
BMC Musculoskelet Disord ; 20(1): 473, 2019 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-31651318

RESUMO

BACKGROUND: Computer Assisted Surgery (CAS) has proven to improve the accuracy in several orthopedic procedures. Therefore we used this technique to evaluate femoral component positioning in Hip Resurfacing Arthroplasty (HRA). The aim of this study was to evaluate imageless CAS compared to manually implanted femoral components and subsequently evaluates Patient Related Outcome Measures (PROMs). We hypothesized that the use of CAS optimizes the position of the femoral component and improves PROMs. METHODS: This is a multicenter, single-blinded, randomized, controlled trial of two groups. In the CAS group guiding of the femoral component was done with imageless navigation. In the Conventional (control) group the femoral component was placed manually according to the preplanned position. The primary outcome measure consists of a maximum of 3 degrees difference between the postoperative Stem Shaft Angle (SSA) and preplanned SSA. Secondary outcome measures consist of the Hip disability and Osteoarthritis Outcome Scale (HOOS), the Harris Hip Score (HHS) and Visual Analogue Scale (VAS) pain score. RESULTS: A total of 122 patients were randomized, 61 in the CAS group and 61 in the conventional group. There was no significant differences in accuracy of femoral implant position. The mean difference between the postoperative- and preplanned SSA was - 2.26 and - 1.75 degrees (more varus) respectively in the CAS and Conventional group. After surgery both groups show significant improvement in all PROMs compared to the baseline measurements, with no significant differences between the groups. CONCLUSION: Our cohort indicates no benefit for the use of CAS in accuracy of placement of the femoral component in HRA compared to manual implantation. There are no clinical differences in PROMs after 1 year follow up. This study showed no added value and no justification for the use of CAS in femoral component positioning in HRA. TRIAL REGISTRATION: This trial is registered at ClinicalTrails.gov ( https://clinicaltrials.gov/ ) on the 25th of October 2006: NCT00391937. LEVEL OF INCIDENCE: Level IIb, multicenter randomized controlled trial.


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Medidas de Resultados Relatados pelo Paciente , Cirurgia Assistida por Computador/métodos , Adulto , Artroplastia de Quadril/instrumentação , Feminino , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Período Pós-Operatório , Radiografia , Método Simples-Cego , Cirurgia Assistida por Computador/instrumentação
4.
Appl Radiat Isot ; 124: 100-105, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28363158

RESUMO

Thorium-227 is currently undergoing evaluation as a potential radionuclide for targeted cancer therapy, and as such a high chemical purity of the material is required. To establish a reliable procedure for radiochemical isolation of 227Th from the parent 227Ac and decay progeny, which includes the radiotherapeutic 223Ra, the performance of three different separation schemes based on ion-exchange and extraction chromatography have been evaluated. The results suggest that both ion exchange and extraction chromatographic techniques can be successfully used for the separation of 227Th from its decay progeny, however extraction chromatographic resins demonstrate favourable performance in terms of Th recovery and purification from radionuclide impurities.


Assuntos
Cromatografia por Troca Iônica/métodos , Compostos Radiofarmacêuticos/isolamento & purificação , Tório/isolamento & purificação , Actínio/isolamento & purificação , Partículas alfa , Germânio , Humanos , Resinas de Troca Iônica , Produtos de Decaimento de Radônio/isolamento & purificação , Espectrometria gama , Espectrofotometria Atômica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA