Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Epilepsy Behav ; 143: 109229, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37148703

RESUMO

OBJECTIVE: During the presurgical evaluation, manual electrical source imaging (ESI) provides clinically useful information in one-third of the patients but it is time-consuming and requires specific expertise. This prospective study aims to assess the clinical added value of a fully automated ESI analysis in a cohort of patients with MRI-negative epilepsy and describe its diagnostic performance, by evaluating sublobar concordance with stereo-electroencephalography (SEEG) results and surgical resection and outcome. METHODS: All consecutive patients referred to the Center for Refractory Epilepsy (CRE) of St-Luc University Hospital (Brussels, Belgium) for presurgical evaluation between 15/01/2019 and 31/12/2020 meeting the inclusion criteria, were recruited to the study. Interictal ESI was realized on low-density long-term EEG monitoring (LD-ESI) and, whenever available, high-density EEG (HD-ESI), using a fully automated analysis (Epilog PreOp, Epilog NV, Ghent, Belgium). The multidisciplinary team (MDT) was asked to formulate hypotheses about the epileptogenic zone (EZ) location at sublobar level and make a decision on further management for each patient at two distinct moments: i) blinded to ESI and ii) after the presentation and clinical interpretation of ESI. Results leading to a change in clinical management were considered contributive. Patients were followed up to assess whether these changes lead to concordant results on stereo-EEG (SEEG) or successful epilepsy surgery. RESULTS: Data from all included 29 patients were analyzed. ESI led to a change in the management plan in 12/29 patients (41%). In 9/12 (75%), modifications were related to a change in the plan of the invasive recording. In 8/9 patients, invasive recording was performed. In 6/8 (75%), the intracranial EEG recording confirmed the localization of the ESI at a sublobar level. So far, 5/12 patients, for whom the management plan was changed after ESI, were operated on and have at least one-year postoperative follow-up. In all cases, the EZ identified by ESI was included in the resection zone. Among these patients, 4/5 (80%) are seizure-free (ILAE 1) and one patient experienced a seizure reduction of more than 50% (ILAE 4). CONCLUSIONS: In this single-center prospective study, we demonstrated the added value of automated ESI in the presurgical evaluation of MRI-negative cases, especially in helping to plan the implantation of depth electrodes for SEEG, provided that ESI results are integrated into the whole multimodal evaluation and clinically interpreted.


Assuntos
Epilepsia Resistente a Medicamentos , Epilepsia , Humanos , Estudos Prospectivos , Epilepsia/diagnóstico por imagem , Epilepsia/cirurgia , Imageamento por Ressonância Magnética/métodos , Eletroencefalografia/métodos , Eletrocorticografia , Epilepsia Resistente a Medicamentos/diagnóstico por imagem , Epilepsia Resistente a Medicamentos/cirurgia
2.
Epilepsia ; 64(4): 951-961, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36346269

RESUMO

OBJECTIVE: Electric source imaging (ESI) of interictal epileptiform discharges (IEDs) has shown significant yield in numerous studies; however, its implementation at most centers is labor- and cost-intensive. Semiautomatic ESI analysis (SAEA) has been proposed as an alternative and has previously shown benefit. Computer-assisted automatic spike cluster retrieval, averaging, and source localization are carried out for each cluster and are then reviewed by an expert neurophysiologist, to determine their relevance for the individual case. Here, we examine its yield in a prospective single center study. METHOD: Between 2017 and 2022, 122 patients underwent SAEA. Inclusion criteria for the current study were unifocal epilepsy disorder, epilepsy surgery with curative purpose, and postoperative follow-up of 2 years or more. All patients (N=40) had continuous video-electroencephalographic (EEG) monitoring with 37 scalp electrodes, which underwent SAEA. Forty patients matched our inclusion criteria. RESULTS: Twenty patients required intracranial monitoring; 13 were magnetic resonance imaging (MRI)-negative. Mean duration of analyzed EEG was 4.3 days (±3.1 days), containing a mean of 12 749 detected IEDs (±22 324). The sensitivity, specificity, and accuracy of SAEA for localizing the epileptogenic focus of the entire group were 74.3%, 80%, and 75%, respectively, leading to an odds ratio (OR) of 11.5 to become seizure-free if the source was included in the resection volume (p < .05). In patients with extratemporal lobe epilepsy, our results indicated an accuracy of 68% (OR=11.7). For MRI-negative patients (n = 13) and patients requiring intracranial EEG (n = 20), we found a similarly high accuracy of 84.6% (OR=19) and 75% (OR = 15.9), respectively. SIGNIFICANCE: In this prospective study of SAEA of long-term video-EEG, spanning several days, we found excellent localizing information and a high yield, even in difficult patient groups. This compares favorably to high-density ESI, most likely due to marked improved signal-to-noise ratio of the averaged IEDs. We propose including ESI, or SAEA, in the workup of all patients who are referred for epilepsy surgery.


Assuntos
Epilepsias Parciais , Epilepsia , Humanos , Estudos Prospectivos , Eletroencefalografia/métodos , Epilepsia/diagnóstico por imagem , Epilepsia/cirurgia , Epilepsias Parciais/cirurgia , Convulsões/diagnóstico por imagem , Convulsões/cirurgia , Imageamento por Ressonância Magnética/métodos
3.
Seizure ; 92: 244-251, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34626920

RESUMO

PURPOSE: To study the accuracy of automated interictal EEG source localisation based on high-density EEG, and to compare it to low-density EEG. METHODS: Thirty patients operated for pharmacoresistant focal epilepsy were retrospectively examined. Twelve months after resective brain surgery, 18 were seizure-free or had 'auras' only, while 12 had persistence of disabling seizures. Presurgical 257-channel EEG lasting 3-20 h was down-sampled to 25, 40, and 204 channels for separate analyses. For each electrode setup, interictal spikes were detected, clustered, and averaged automatically before validation by an expert reviewer. An individual 6-layer finite difference head model and the standardised low-resolution electromagnetic tomography were used to localise the maximum source activity of the most prevalent spike. Sublobar concordance with the resected brain area was visually assessed and related to favourable vs. unfavourable postsurgical outcome. RESULTS: Depending on the EEG setup, epileptic spikes were detected in 21-24 patients (70-80%). The median number of single spikes per average was 470 (range 17-15,066). Diagnostic sensitivity of EEG source localisation was 58-75%, specificity was 50-67%, and overall accuracy was 55-71%. There were no significant differences between low- and high-density EEG setups with 25 to 257 electrodes. CONCLUSION: Automated high-density EEG source localisation provides meaningful information in the majority of cases. With hundreds of single spikes averaged, diagnostic accuracy is similar in high- and low-density EEG. Therefore, low-density EEG may be sufficient for interictal EEG source localisation if high numbers of spikes are available.


Assuntos
Eletroencefalografia , Epilepsias Parciais , Mapeamento Encefálico , Epilepsias Parciais/diagnóstico , Epilepsias Parciais/cirurgia , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Convulsões/diagnóstico
4.
Clin Neurophysiol ; 132(12): 2965-2978, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34715421

RESUMO

OBJECTIVE: To evaluate the accuracy of automatedinterictallow-density electrical source imaging (LD-ESI) to define the insular irritative zone (IZ) by comparing the simultaneous interictal ESI localization with the SEEG interictal activity. METHODS: Long-term simultaneous scalp electroencephalography (EEG) and stereo-EEG (SEEG) with at least one depth electrode exploring the operculo-insular region(s) were analyzed. Automated interictal ESI was performed on the scalp EEG using standardized low-resolution brain electromagnetic tomography (sLORETA) and individual head models. A two-step analysis was performed: i) sublobar concordance betweencluster-based ESI localization and SEEG-based IZ; ii) time-locked ESI-/SEEG analysis. Diagnostic accuracy values were calculated using SEEG as reference standard. Subgroup analysis wascarried out, based onthe involvement of insular contacts in the seizure onset and patterns of insular interictal activity. RESULTS: Thirty patients were included in the study. ESI showed an overall accuracy of 53% (C.I. 29-76%). Sensitivity and specificity were calculated as 53% (C.I. 29-76%), 55% (C.I. 23-83%) respectively. Higher accuracy was found in patients with frequent and dominant interictal insular spikes. CONCLUSIONS: LD-ESI defines with good accuracy the insular implication in the IZ, which is not possible with classical interictalscalpEEG interpretation. SIGNIFICANCE: Automated LD-ESI may be a valuable additional tool to characterize the epileptogenic zone in epilepsies with suspected insular involvement.


Assuntos
Eletroencefalografia/métodos , Epilepsia/fisiopatologia , Córtex Insular/fisiopatologia , Adolescente , Adulto , Idoso , Mapeamento Encefálico/métodos , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Couro Cabeludo/fisiopatologia , Adulto Jovem
5.
Seizure ; 78: 18-30, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32151969

RESUMO

PURPOSE: To evaluate the yield of Functional Connectivity (FC) in addition to low-density ictal Electrical Source Imaging (ESI) in extratemporal lobe epilepsy (ETLE), using an automated algorithm for analysis. METHOD: Long-term EEG monitoring of consecutive ETLE patients who underwent surgery was reviewed by epileptologists, and seizure onsets characterized by rhythmical activity were identified. A spectrogram-based algorithm was developed to select objectively the parameters of ESI analysis. Two methods for SOZ localization were compared: i) ESI power, based on LORETA exclusively; ii) ESI + FC, including a Granger causality-based connectivity analysis. Results were determined at a sublobar level. The resection zone, in relation to 1-year follow-up surgical outcome, was considered as reference standard for diagnostic accuracy analyses. RESULTS: Ninety-four seizures from 24 patients were analyzed. At seizure-level, ESI power showed 36 % sensitivity and 72 % specificity (accuracy: 45 %). ESI + FC significantly improved the accuracy, with 52 % sensitivity and 84 % specificity (accuracy: 61 %, p = 0.04). Results of ESI + FC were equally valuable in patients with lateralized or bilateral/generalized visual interpretation of ictal EEG. In a patient level sub-analysis, upon blinded clinical interpretation, ESI + FC showed a correct localization in 67 % of patients and substantial inter-rater agreement (kappa = 0.64), against 27 % achieved by ESI power, with fair inter-rater agreement (kappa = 0.37). CONCLUSION: FC significantly improves SOZ localization compared to ESI solely in ETLE. Ictal ESI + FC could represent a novel option in the armamentarium of presurgical evaluation, aiding also in patients with visually non-localizable scalp ictal EEG. Prospective studies evaluating the clinical added value of automated low-density ictal ESI may be justified.


Assuntos
Córtex Cerebral , Conectoma/métodos , Epilepsia Resistente a Medicamentos/diagnóstico , Eletroencefalografia/métodos , Epilepsias Parciais/diagnóstico , Adolescente , Adulto , Córtex Cerebral/fisiopatologia , Criança , Conectoma/normas , Epilepsia Resistente a Medicamentos/fisiopatologia , Epilepsia Resistente a Medicamentos/cirurgia , Eletroencefalografia/normas , Epilepsias Parciais/fisiopatologia , Epilepsias Parciais/cirurgia , Feminino , Seguimentos , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Adulto Jovem
6.
Clin Neurophysiol ; 129(11): 2403-2410, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30278389

RESUMO

OBJECTIVE: To evaluate the accuracy of automated EEG source imaging (ESI) in localizing epileptogenic zone. METHODS: Long-term EEG, recorded with the standard 25-electrode array of the IFCN, from 41 consecutive patients with focal epilepsy who underwent resective surgery, were analyzed blinded to the surgical outcome. The automated analysis comprised spike-detection, clustering and source imaging at the half-rising time and at the peak of each spike-cluster, using individual head-models with six tissue-layers and a distributed source model (sLORETA). The fully automated approach presented ESI of the cluster with the highest number of spikes, at the half-rising time. In addition, a physician involved in the presurgical evaluation of the patients, evaluated the automated ESI results (up to four clusters per patient) in clinical context and selected the dominant cluster and the analysis time-point (semi-automated approach). The reference standard was location of the resected area and outcome one year after operation. RESULTS: Accuracy was 61% (95% CI: 45-76%) for the fully automated approach and 78% (95% CI: 62-89%) for the semi-automated approach. CONCLUSION: Automated ESI has an accuracy similar to previously reported neuroimaging methods. SIGNIFICANCE: Automated ESI will contribute to increased utilization of source imaging in the presurgical evaluation of patients with epilepsy.


Assuntos
Automação/métodos , Eletroencefalografia/métodos , Epilepsia/diagnóstico , Adolescente , Adulto , Automação/normas , Criança , Eletroencefalografia/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
7.
Neuroimage Clin ; 16: 689-698, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29034162

RESUMO

Electrical source imaging (ESI) from interictal scalp EEG is increasingly validated and used as a valuable tool in the presurgical evaluation of epilepsy as a reflection of the irritative zone. ESI of ictal scalp EEG to localize the seizure onset zone (SOZ) remains challenging. We investigated the value of an approach for ictal imaging using ESI and functional connectivity analysis (FC). Ictal scalp EEG from 111 seizures in 27 patients who had Engel class I outcome at least 1 year following resective surgery was analyzed. For every seizure, an artifact-free epoch close to the seizure onset was selected and ESI using LORETA was applied. In addition, the reconstructed sources underwent FC using the spectrum-weighted Adaptive Directed Transfer Function. This resulted in the estimation of the SOZ in two ways: (i) the source with maximal power after ESI, (ii) the source with the strongest outgoing connections after combined ESI and FC. Next, we calculated the distance between the estimated SOZ and the border of the resected zone (RZ) for both approaches and called this the localization error ((i) LEpow and (ii) LEconn respectively). By comparing LEpow and LEconn, we assessed the added value of FC. The source with maximal power after ESI was inside the RZ (LEpow = 0 mm) in 31% of the seizures and estimated within 10 mm from the border of the RZ (LEpow ≤ 10 mm) in 42%. Using ESI and FC, these numbers increased to 72% for LEconn = 0 mm and 94% for LEconn ≤ 10 mm. FC provided a significant added value to ESI alone (p < 0.001). ESI combined with subsequent FC is able to localize the SOZ in a non-invasive way with high accuracy. Therefore it could be a valuable tool in the presurgical evaluation of epilepsy.


Assuntos
Encéfalo/fisiopatologia , Epilepsia Resistente a Medicamentos/complicações , Eletroencefalografia/métodos , Convulsões/diagnóstico , Adolescente , Adulto , Criança , Epilepsia Resistente a Medicamentos/cirurgia , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Convulsões/complicações , Convulsões/cirurgia , Processamento de Sinais Assistido por Computador , Adulto Jovem
8.
Front Neurosci ; 11: 156, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28428738

RESUMO

Presurgical evaluation of brain neural activity is commonly carried out in refractory epilepsy patients to delineate as accurately as possible the seizure onset zone (SOZ) before epilepsy surgery. In practice, any subjective interpretation of electroencephalographic (EEG) recordings is hindered mainly because of the highly stochastic behavior of the epileptic activity. We propose a new method for dynamic source connectivity analysis that aims to accurately localize the seizure onset zones by explicitly including temporal, spectral, and spatial information of the brain neural activity extracted from EEG recordings. In particular, we encode the source nonstationarities in three critical stages of processing: Inverse problem solution, estimation of the time courses extracted from the regions of interest, and connectivity assessment. With the aim to correctly encode all temporal dynamics of the seizure-related neural network, a directed functional connectivity measure is employed to quantify the information flow variations over the time window of interest. Obtained results on simulated and real EEG data confirm that the proposed approach improves the accuracy of SOZ localization.

9.
Epilepsia Open ; 2(3): 322-333, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-29588961

RESUMO

Objective: We investigated the performance of automatic spike detection and subsequent electroencephalogram (EEG) source imaging to localize the epileptogenic zone (EZ) from long-term EEG recorded during video-EEG monitoring. Methods: In 32 patients, spikes were automatically detected in the EEG and clustered according to their morphology. The two spike clusters with most single events in each patient were averaged and localized in the brain at the half-rising time and peak of the spike using EEG source imaging. On the basis of the distance from the sources to the resection and the known patient outcome after surgery, the performance of the automated EEG analysis to localize the EZ was quantified. Results: In 28 out of the 32 patients, the automatically detected spike clusters corresponded with the reported interictal findings. The median distance to the resection in patients with Engel class I outcome was 6.5 and 15 mm for spike cluster 1 and 27 and 26 mm for cluster 2, at the peak and the half-rising time of the spike, respectively. Spike occurrence (cluster 1 vs. cluster 2) and spike timing (peak vs. half-rising) significantly influenced the distance to the resection (p < 0.05). For patients with Engel class II, III, and IV outcomes, the median distance increased to 36 and 36 mm for cluster 1. Localizing spike cluster 1 at the peak resulted in a sensitivity of 70% and specificity of 100%, positive prediction value (PPV) of 100%, and negative predictive value (NPV) of 53%. Including the results of spike cluster 2 led to an increased sensitivity of 79% NPV of 55% and diagnostic OR of 11.4, while the specificity dropped to 75% and the PPV to 90%. Significance: We showed that automated analysis of long-term EEG recordings results in a high sensitivity and specificity to localize the epileptogenic focus.

10.
Brain Topogr ; 30(2): 257-271, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27853892

RESUMO

Epilepsy surgery is the most efficient treatment option for patients with refractory epilepsy. Before surgery, it is of utmost importance to accurately delineate the seizure onset zone (SOZ). Non-invasive EEG is the most used neuroimaging technique to diagnose epilepsy, but it is hard to localize the SOZ from EEG due to its low spatial resolution and because epilepsy is a network disease, with several brain regions becoming active during a seizure. In this work, we propose and validate an approach based on EEG source imaging (ESI) combined with functional connectivity analysis to overcome these problems. We considered both simulations and real data of patients. Ictal epochs of 204-channel EEG and subsets down to 32 channels were analyzed. ESI was done using realistic head models and LORETA was used as inverse technique. The connectivity pattern between the reconstructed sources was calculated, and the source with the highest number of outgoing connections was selected as SOZ. We compared this algorithm with a more straightforward approach, i.e. selecting the source with the highest power after ESI as the SOZ. We found that functional connectivity analysis estimated the SOZ consistently closer to the simulated EZ/RZ than localization based on maximal power. Performance, however, decreased when 128 electrodes or less were used, especially in the realistic data. The results show the added value of functional connectivity analysis for SOZ localization, when the EEG is obtained with a high-density setup. Next to this, the method can potentially be used as objective tool in clinical settings.


Assuntos
Encéfalo/fisiopatologia , Epilepsias Parciais/fisiopatologia , Convulsões/fisiopatologia , Adulto , Algoritmos , Eletrodos , Eletroencefalografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neuroimagem
11.
Brain Topogr ; 30(1): 46-59, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27722839

RESUMO

The visual interpretation of intracranial EEG (iEEG) is the standard method used in complex epilepsy surgery cases to map the regions of seizure onset targeted for resection. Still, visual iEEG analysis is labor-intensive and biased due to interpreter dependency. Multivariate parametric functional connectivity measures using adaptive autoregressive (AR) modeling of the iEEG signals based on the Kalman filter algorithm have been used successfully to localize the electrographic seizure onsets. Due to their high computational cost, these methods have been applied to a limited number of iEEG time-series (<60). The aim of this study was to test two Kalman filter implementations, a well-known multivariate adaptive AR model (Arnold et al. 1998) and a simplified, computationally efficient derivation of it, for their potential application to connectivity analysis of high-dimensional (up to 192 channels) iEEG data. When used on simulated seizures together with a multivariate connectivity estimator, the partial directed coherence, the two AR models were compared for their ability to reconstitute the designed seizure signal connections from noisy data. Next, focal seizures from iEEG recordings (73-113 channels) in three patients rendered seizure-free after surgery were mapped with the outdegree, a graph-theory index of outward directed connectivity. Simulation results indicated high levels of mapping accuracy for the two models in the presence of low-to-moderate noise cross-correlation. Accordingly, both AR models correctly mapped the real seizure onset to the resection volume. This study supports the possibility of conducting fully data-driven multivariate connectivity estimations on high-dimensional iEEG datasets using the Kalman filter approach.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/fisiopatologia , Eletrocorticografia/métodos , Rede Nervosa/fisiopatologia , Convulsões/fisiopatologia , Adulto , Algoritmos , Simulação por Computador , Feminino , Humanos , Masculino , Modelos Neurológicos , Adulto Jovem
12.
Neuroimage Clin ; 11: 252-263, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26958464

RESUMO

Electrical source imaging of interictal spikes observed in EEG recordings of patients with refractory epilepsy provides useful information to localize the epileptogenic focus during the presurgical evaluation. However, the selection of the time points or time epochs of the spikes in order to estimate the origin of the activity remains a challenge. In this study, we consider a Bayesian EEG source imaging technique for distributed sources, i.e. the multiple volumetric sparse priors (MSVP) approach. The approach allows to estimate the time courses of the intensity of the sources corresponding with a specific time epoch of the spike. Based on presurgical averaged interictal spikes in six patients who were successfully treated with surgery, we estimated the time courses of the source intensities for three different time epochs: (i) an epoch starting 50 ms before the spike peak and ending at 50% of the spike peak during the rising phase of the spike, (ii) an epoch starting 50 ms before the spike peak and ending at the spike peak and (iii) an epoch containing the full spike time period starting 50 ms before the spike peak and ending 230 ms after the spike peak. To identify the primary source of the spike activity, the source with the maximum energy from 50 ms before the spike peak till 50% of the spike peak was subsequently selected for each of the time windows. For comparison, the activity at the spike peaks and at 50% of the peaks was localized using the LORETA inversion technique and an ECD approach. Both patient-specific spherical forward models and patient-specific 5-layered finite difference models were considered to evaluate the influence of the forward model. Based on the resected zones in each of the patients, extracted from post-operative MR images, we compared the distances to the resection border of the estimated activity. Using the spherical models, the distances to the resection border for the MSVP approach and each of the different time epochs were in the same range as the LORETA and ECD techniques. We found distances smaller than 23 mm, with robust results for all the patients. For the finite difference models, we found that the distances to the resection border for the MSVP inversions of the full spike time epochs were generally smaller compared to the MSVP inversions of the time epochs before the spike peak. The results also suggest that the inversions using the finite difference models resulted in slightly smaller distances to the resection border compared to the spherical models. The results we obtained are promising because the MSVP approach allows to study the network of the estimated source-intensities and allows to characterize the spatial extent of the underlying sources.


Assuntos
Mapeamento Encefálico , Ondas Encefálicas/fisiologia , Epilepsia/fisiopatologia , Adolescente , Adulto , Eletroencefalografia , Epilepsia/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Modelos Teóricos , Estudos Retrospectivos , Fatores de Tempo , Adulto Jovem
13.
Neuropsychologia ; 64: 349-59, 2014 11.
Artigo em Inglês | MEDLINE | ID: mdl-25281310

RESUMO

A neural hallmark of developmental stuttering is abnormal articulatory programming. One of the neurophysiological substrates of articulatory preparation is the contingent negative variation (CNV). Unfortunately, CNV tasks are rarely performed in persons who stutter and mainly focus on the effect of task variation rather than on interindividual variation in stutter related variables. However, variations in motor programming seem to be related to variation in stuttering frequency. The current study presents a case report of acquired stuttering following stroke and stroke related surgery in the left superior temporal gyrus. A speech related CNV task was administered at four points in time with differences in stuttering severity and frequency. Unexpectedly, CNV amplitudes at electrode sites approximating bilateral motor and left inferior frontal gyrus appeared to be inversely proportional to stuttering frequency. The higher the stuttering frequency, the lower the activity for articulatory preparation. Thus, the amount of disturbance in motor programming seems to determine stuttering frequency. At right frontal electrodes, a relative increase in CNV amplitude was seen at the test session with most severe stuttering. Right frontal overactivation is cautiously suggested to be a compensation strategy. In conclusion, late CNV amplitude elicited by a relatively simple speech task seems to be able to provide an objective, neural correlate of stuttering frequency. The present case report supports the hypothesis that motor preparation has an important role in stuttering.


Assuntos
Encéfalo/fisiopatologia , Variação Contingente Negativa/fisiologia , Gagueira/fisiopatologia , Adulto , Eletroencefalografia , Feminino , Humanos , Fala/fisiologia , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/fisiopatologia , Gagueira/etiologia
14.
Epilepsia ; 54(8): 1409-18, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23647147

RESUMO

PURPOSE: Fifteen percent to 25% of patients with refractory epilepsy require invasive video-electroencephalography (EEG) monitoring (IVEM) to precisely delineate the ictal-onset zone. This delineation based on the recorded intracranial EEG (iEEG) signals occurs visually by the epileptologist and is therefore prone to human mistakes. The purpose of this study is to investigate whether effective connectivity analysis of intracranially recorded EEG during seizures provides an objective method to localize the ictal-onset zone. METHODS: In this study data were analyzed from eight patients who underwent IVEM at Ghent University Hospital in Belgium. All patients had a focal ictal onset and were seizure-free following resective surgery. The effective connectivity pattern was calculated during the first 20 s of ictal rhythmic iEEG activity. The out-degree, which is reflective of the number of outgoing connections, was calculated for each electrode contact for every single seizure during these 20 s. The seizure specific out-degrees were summed per patient to obtain the total out-degree. The electrode contact with the highest total out-degree was considered indicative of localization of the ictal-onset zone. This result was compared to the conclusion of the visual analysis of the epileptologist and the resected brain region segmented from postoperative magnetic resonance imaging (MRI). KEY FINDINGS: In all eight patients the electrode contact with the highest total out-degree was among the contacts identified by the epileptologist as the ictal onset. This contact, that we named "the driver," always laid within the resected brain region. Furthermore, the patient-specific connectivity patterns were consistent over the majority of seizures. SIGNIFICANCE: In this study we demonstrated the feasibility of correctly localizing the ictal-onset zone from iEEG recordings by using effective connectivity analysis during the first 20 s of ictal rhythmic iEEG activity.


Assuntos
Ondas Encefálicas/fisiologia , Encéfalo/fisiopatologia , Epilepsia , Adulto , Encéfalo/patologia , Eletrodos , Eletroencefalografia , Epilepsia/patologia , Epilepsia/fisiopatologia , Epilepsia/cirurgia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos/métodos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA