Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
NMR Biomed ; 33(12): e4372, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32701224

RESUMO

Separating the decay signal from diffusion-weighted scans into two or more components can be challenging. The phasor technique is well established in the field of optical microscopy for visualization and separation of fluorescent dyes with different lifetimes. The use of the phasor technique for separation of diffusion-weighted decay signals was recently proposed. In this study, we investigate the added value of this technique for fitting decay models and visualization of decay rates. Phasor visualization was performed in five glioblastoma patients. Using simulations, the influence of incorrect diffusivity values and of the number of b-values on fitting a three-component model with fixed diffusivities (dubbed "unmixing") was investigated for both a phasor-based fit and a linear least squares (LLS) fit. Phasor-based intravoxel incoherent motion (IVIM) fitting was compared with nonlinear least squares (NLLS) and segmented fitting (SF) methods in terms of accuracy and precision. The distributions of the parameter estimates of simulated data were compared with those obtained in a healthy volunteer. In the phasor visualizations of two glioblastoma patients, a cluster of points was observed that was not seen in healthy volunteers. The identified cluster roughly corresponded to the enhanced edge region of the tumor of two glioblastoma patients visible on fluid-attenuated inversion recovery (FLAIR) images. For fitting decay models the usefulness of the phasor transform is less pronounced, but the additional knowledge gained from the geometrical configuration of phasor space can aid fitting routines. This has led to slightly improved fitting results for the IVIM model: phasor-based fitting yielded parameter maps with higher precision than the NLLS and SF methods for parameters f and D (interquartile range [IQR] for f: NLLS 27, SF 12, phasor 5.7%; IQR for D: NLLS 0.28, SF 0.18, phasor 0.10 µm2 /s). For unmixing, LLS fitting slightly but consistently outperformed phasor-based fitting in all of the tested scenarios.


Assuntos
Algoritmos , Imagem de Difusão por Ressonância Magnética , Processamento de Sinais Assistido por Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Imagens de Fantasmas , Probabilidade
2.
J Magn Reson Imaging ; 52(5): 1374-1382, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32491246

RESUMO

BACKGROUND: Differences in imaging parameters influence computer-extracted parenchymal enhancement measures from breast MRI. PURPOSE: To investigate the effect of differences in dynamic contrast-enhanced MRI acquisition parameter settings on quantitative parenchymal enhancement of the breast, and to evaluate harmonization of contrast-enhancement values with respect to flip angle and repetition time. STUDY TYPE: Retrospective. PHANTOM/POPULATIONS: We modeled parenchymal enhancement using simulations, a phantom, and two cohorts (N = 398 and N = 302) from independent cancer centers. SEQUENCE FIELD/STRENGTH: 1.5T dynamic contrast-enhanced T1 -weighted spoiled gradient echo MRI. Vendors: Philips, Siemens, General Electric Medical Systems. ASSESSMENT: We assessed harmonization of parenchymal enhancement in simulations and phantom by varying the MR parameters that influence the amount of T1 -weighting: flip angle (8°-25°) and repetition time (4-12 msec). We calculated the median and interquartile range (IQR) of the enhancement values before and after harmonization. In vivo, we assessed overlap of quantitative parenchymal enhancement in the cohorts before and after harmonization using kernel density estimations. Cohort 1 was scanned with flip angle 20° and repetition time 8 msec; cohort 2 with flip angle 10° and repetition time 6 msec. STATISTICAL TESTS: Paired Wilcoxon signed-rank-test of bootstrapped kernel density estimations. RESULTS: Before harmonization, simulated enhancement values had a median (IQR) of 0.46 (0.34-0.49). After harmonization, the IQR was reduced: median (IQR): 0.44 (0.44-0.45). In the phantom, the IQR also decreased, median (IQR): 0.96 (0.59-1.22) before harmonization, 0.96 (0.91-1.02) after harmonization. Harmonization yielded significantly (P < 0.001) better overlap in parenchymal enhancement between the cohorts: median (IQR) was 0.46 (0.37-0.58) for cohort 1 vs. 0.37 (0.30-0.44) for cohort 2 before harmonization (57% overlap); and 0.35 (0.28-0.43) vs. .0.37 (0.30-0.44) after harmonization (85% overlap). DATA CONCLUSION: The proposed practical harmonization method enables an accurate comparison between patients scanned with differences in imaging parameters. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 4.


Assuntos
Mama , Imageamento por Ressonância Magnética , Mama/diagnóstico por imagem , Humanos , Aumento da Imagem , Imagens de Fantasmas , Reprodutibilidade dos Testes , Estudos Retrospectivos
3.
Magn Reson Med ; 84(2): 1000-1010, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31880346

RESUMO

PURPOSE: Inhomogeneous excitation at ultrahigh field strengths (7T and above) compromises the reliability of quantified dynamic contrast-enhanced breast MRI. This can hamper the introduction of ultrahigh field MRI into the clinic. Compensation for this non-uniformity effect can consist of both hardware improvements and post-acquisition corrections. This paper investigated the correctable radiofrequency transmit ( B1+ ) range post-acquisition in both simulations and patient data for 7T MRI. METHODS: Simulations were conducted to determine the minimum B1+ level at which corrections were still beneficial because of noise amplification. Two correction strategies leading to differences in noise amplification were tested. The effect of the corrections on a 7T patient data set (N = 38) with a wide range of B1+ levels was investigated in terms of time-intensity curve types as well as washin, washout and peak enhancement values. RESULTS: In simulations assuming a common amount of T1 saturation, the lowest B1+ level at which the SNR of the corrected images was at least that of the original precontrast image was 43% of the nominal angle. After correction, time-intensity curve types changed in 24% of included patients, and the distribution of curve types corresponded better to the distribution found in literature. Additionally, the overlap between the distributions of washin, washout, and peak enhancement values for grade 1 and grade 2 tumors was slightly reduced. CONCLUSION: Although the correctable range varies with the amount of T1 saturation, post-acquisition correction for inhomogeneous excitation was feasible down to B1+ levels of 43% of the nominal angle in vivo.


Assuntos
Mama , Imageamento por Ressonância Magnética , Mama/diagnóstico por imagem , Humanos , Aumento da Imagem , Ondas de Rádio , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA