Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Anaesthesia ; 77(2): 164-174, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34555189

RESUMO

The association between intra-operative hypotension and postoperative acute kidney injury, mortality and length of stay has not been comprehensively evaluated in a large single-centre hip fracture population. We analysed electronic anaesthesia records of 1063 patients undergoing unilateral hip fracture surgery, collected from 2015 to 2018. Acute kidney injury, 3-, 30- and 365-day mortality and length of stay were evaluated to assess the relationship between intra-operative hypotension absolute values (≤ 55, 60, 65, 70 and 75 mmHg) and duration of hypotension. The rate of acute kidney injury was 23.7%, mortality at 3-, 30- and 365 days was 3.7%, 8.0% and 25.3%, respectively, and median (IQR [range]) length of stay 8 (6-12 [0-99]) days. Median (IQR [range]) time ≤ MAP 55, 60, 65, 70 and 75 mmHg was 0 (0-0.5[0-72.1]); 0 (0-4.4 [0-104.9]); 2.2 (0-8.7 [0-144.2]); 6.6 (2.2-19.7 [0-198.8]); 17.5 (6.6-37.1 [0-216.3]) minutes, and percentage of surgery time below these thresholds was 1%, 2.5%, 7.9%, 12% and 21% respectively. There were some univariate associations between hypotension and mortality; however, these were no longer evident in multivariable analysis. Multivariable analysis found no association between hypotension and acute kidney injury. Acute kidney injury was associated with male sex, antihypertensive medications and cardiac/renal comorbidities. Three-day mortality was associated with delay to surgery ? 48 hours, whilst 30-day and 365-day mortality was associated with delay to surgery ≥ 48 hours, impaired cognition and cardiac/renal comorbidities. While the rate of acute kidney injury was similar to other studies, use of vasopressors and fluids to reduce the time spent at hypotensive levels failed to reduce this complication. Intra-operative hypotension at the levels observed in this cohort may not be an important determinant of acute kidney injury, postoperative mortality and length of stay.


Assuntos
Injúria Renal Aguda/mortalidade , Tratamento de Emergência/mortalidade , Fraturas do Quadril/mortalidade , Hipotensão/mortalidade , Complicações Intraoperatórias/mortalidade , Complicações Pós-Operatórias/mortalidade , Injúria Renal Aguda/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Tratamento de Emergência/tendências , Feminino , Fraturas do Quadril/cirurgia , Humanos , Hipotensão/diagnóstico , Complicações Intraoperatórias/diagnóstico , Tempo de Internação/tendências , Masculino , Monitorização Intraoperatória/mortalidade , Monitorização Intraoperatória/tendências , Mortalidade/tendências , Complicações Pós-Operatórias/diagnóstico , Estudos Prospectivos , Estudos Retrospectivos
2.
Anesthesiology ; 92(2): 550-8, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10691244

RESUMO

BACKGROUND: Dynamic intraesophageal pressure (Pes) is used to estimate intrapleural pressure (Ppl) to calculate lung compliance and resistance. This study investigated the nonhuman primate Ppl-Pes tissue barrier frequency response and the dynamic response requirements of Pes manometers. METHODS: In healthy monkeys and monkeys with acute lung injury undergoing ventilation, simultaneous Ppl and Pes were measured directly to determine the Ppl-Pes tissue barrier amplitude frequency response, using the swept-sine wave technique. The bandwidths of physiologic Pes waveforms acquired during conventional mechanical ventilation were calculated using digital low-pass signal filtering. RESULTS: The Ppl-Pes tissue barrier is amplitude-uniform within the bandwidth of conventional Pes waveforms in healthy and acute lung injury lungs, and does not significantly attenuate Ppl-Pes signal transmission between 1 and 40 Hz. At Pes frequencies higher than conventional clinical regions of interest the Ppl-Pes barrier resonates significantly, is pressure amplitude dependent at low-pressure offsets, and is significantly altered by acute lung injury. Allowing for 5% or less Pes waveform error, the maximum Pes bandwidths during conventional ventilation were 1.9 Hz and 3.4 Hz for physiologic and extreme-case waveforms in healthy lungs and 4.6 Hz and 8.5 Hz during acute lung injury. CONCLUSIONS: In monkeys, the Ppl-Pes tissue barrier has a frequency response suitable for Ppl estimation during low-frequency mechanical ventilation, and Pes manometers should have a minimum uniform frequency response up to 8.5 Hz. However, the Ppl-Pes tissue barrier adversely affects the accurate estimation of dynamic Ppl at high frequencies, with varied airway pressure amplitudes and offsets, such as the Ppl encountered during high-frequency oscillatory ventilation.


Assuntos
Barreira Alveolocapilar/fisiologia , Esôfago/fisiologia , Lesão Pulmonar , Pulmão/fisiologia , Pleura/fisiologia , Doença Aguda , Resistência das Vias Respiratórias/fisiologia , Animais , Cateterismo , Chlorocebus aethiops , Esôfago/fisiopatologia , Feminino , Complacência Pulmonar/fisiologia , Manometria , Pleura/fisiopatologia , Pressão , Respiração Artificial , Transdução de Sinais/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA