Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
J Cataract Refract Surg ; 45(5): 582-586, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30826241

RESUMO

PURPOSE: To evaluate the accuracy of different intraocular lens (IOL) power calculation formulas available on the American Society of Cataract and Refractive Surgery calculator in calculating multifocal IOL power in eyes with previous hyperopic corneal refractive laser surgery. DESIGN: Retrospective case series. SETTING: Amsterdam University Medical Center, University of Amsterdam, and Retina Total Eye Care, Driebergen, the Netherlands. METHODS: This study compared the accuracy of 3 formulas using historical refractive data (ie, Masket, modified Masket, and Barrett True-K) and 3 formulas using no previous refractive data (ie, Shammas, Haigis-L, and Barrett True-K no-history). RESULTS: Sixty-four eyes were included. The variance of the prediction error of the various formulas was similar and ranged from 0.27 D2 to 0.33 D2 (P = .99). The modified Masket formula had a significantly higher median absolute prediction error than the Masket formula, Barrett True-K formula, and mean value of all formulas (P < .001). CONCLUSION: All formulas showed comparable accuracy in predicting IOL power in eyes after hyperopic corneal refractive laser surgery except for the modified Masket formula, which performed less accurately than the Masket formula, Barrett True-K formula, and mean value of all formulas.


Assuntos
Biometria/métodos , Cirurgia da Córnea a Laser , Hiperopia/cirurgia , Implante de Lente Intraocular , Lentes Intraoculares Multifocais , Óptica e Fotônica , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oftalmologia/organização & administração , Facoemulsificação , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sociedades Médicas , Acuidade Visual/fisiologia
2.
J Refract Surg ; 35(1): 54-59, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30633788

RESUMO

PURPOSE: To compare the accuracy of different intraocular lens (IOL) calculation formulas available on the American Society of Cataract and Refractive Surgery (ASCRS) post-refractive surgery IOL power calculator for the prediction of multifocal IOL power after previous corneal refractive laser surgery for myopia. METHODS: An analysis and comparison were performed of the accuracy of three methods using surgically induced change in refraction (ie, Masket, Modified Masket, and Barrett True-K formulas) and three methods using no previous data (ie, Shammas, Haigis-L, and Barrett True-K No History formulas). The average of all formulas was also analyzed and compared. RESULTS: Thirty-six eyes of 36 patients were included. All formulas, except for the Masket, Modified Masket, and Barrett True-K formulas, had myopic mean numerical errors that were significantly different from zero (P ⩽ .01). The median absolute error of the Shammas formula (0.52 diopters [D]) was significantly higher compared to all of the other formulas (P < .05), except for the Haigis-L formula (P = .09). Comparing the formulas using no previous data, the Barrett True-K No History formula had the lowest median absolute error (0.33 D, P < .001). CONCLUSIONS: The Shammas formula showed the least accuracy in predicting IOL power in eyes with multifocal IOL implantation after previous corneal refractive laser surgery for myopia. In eyes with all available data, all formulas performed equally except for the Shammas formula, whereas in eyes lacking historical data, the Barrett True-K No History formula performed best. [J Refract Surg. 2019;35(1):54-59.].


Assuntos
Cirurgia da Córnea a Laser/métodos , Implante de Lente Intraocular , Lentes Intraoculares Multifocais , Miopia/cirurgia , Óptica e Fotônica , Facoemulsificação/métodos , Adulto , Idoso , Astigmatismo/fisiopatologia , Biometria , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia , Acuidade Visual/fisiologia
3.
J Cataract Refract Surg ; 45(1): 72-75, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30391156

RESUMO

PURPOSE: To study straylight before and after posterior polar cataract removal. SETTING: Academic Medical Center, Amsterdam, the Netherlands. DESIGN: Prospective case series. METHODS: Patients diagnosed with posterior polar cataract who agreed to cataract surgery were included in the study. Intraocular straylight was measured before and after surgery with the compensation comparison method using a straylight meter (C-Quant). RESULTS: Measurements were performed on 8 eyes of 4 patients. The mean preoperative corrected distance visual acuity was relatively good (0.15 logarithm of the minimum angle of resolution [logMAR] ± 0.18 (SD). The mean postoperative CDVA was -0.08 ± 0.09 logMAR (P < .01). The mean preoperative straylight was extreme (2.01 ± 0.38 log[s]), 13 times that of a young normal eye; however, it improved postoperatively to 1.04 ± 0.26 log(s) (P < .01). CONCLUSIONS: Straylight in eyes with posterior polar cataract patients can be extremely bothersome, while visual acuity is relatively well preserved. Surgery was effective in lowering straylight levels. For these patients, straylight measurements can help objectively measure the quality of vision complaints, and elevated straylight levels can be an indication for surgery independent of visual acuity.


Assuntos
Catarata/fisiopatologia , Espalhamento de Radiação , Acuidade Visual/fisiologia , Idoso , Técnicas de Diagnóstico Oftalmológico , Feminino , Humanos , Implante de Lente Intraocular , Cristalino/fisiopatologia , Luz , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Estudos Prospectivos
4.
J Cataract Refract Surg ; 44(4): 466-470, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29685778

RESUMO

PURPOSE: To describe the outcomes in terms of the refraction and visual acuity of multifocal intraocular lens (IOL) implantation in patients with previous hyperopic corneal refractive laser surgery. SETTING: Academic Medical Center, University of Amsterdam, Amsterdam, and Retina Total Eye Care, Driebergen, the Netherlands. DESIGN: Retrospective case series. METHODS: Results were analyzed 3 months after implantation of a multifocal IOL (Acrysof Restor SN6AD1) in patients after previous corneal refractive laser surgery for hyperopia. The primary outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and refraction. The secondary outcome measures were the number of laser enhancements and posterior capsule opacification (PCO) rates. RESULTS: Forty eyes of 40 patients were included. Sixteen eyes (40.0%) had lens extraction because of cataract, and 24 eyes (60.0%) had refractive lens exchange. The mean postoperative UDVA was 0.16 logarithm of the minimum angle of resolution (logMAR) ± 0.18 (SD), and the mean postoperative CDVA was 0.01 ± 0.08 logMAR. The mean postoperative spherical equivalent was 0.04 ± 0.92 diopter (D). Twenty-five eyes (62.5%) were within ±0.50 D of emmetropia, and 35 eyes (87.5%) were within ±1.0 D of emmetropia. Nine eyes (22.5%) had a laser enhancement because of a residual refraction error. Eleven eyes (27.5%) had a neodymium:YAG laser capsulotomy because of PCO. CONCLUSIONS: In general, multifocal IOL implantation after corneal refractive laser surgery for hyperopia resulted in good visual acuity and refraction. The magnitude of previous hyperopia did not influence the refractive predictability.


Assuntos
Córnea/cirurgia , Hiperopia/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Lentes Intraoculares Multifocais , Refração Ocular/fisiologia , Adulto , Idoso , Feminino , Humanos , Hiperopia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Reoperação , Estudos Retrospectivos
5.
Int Ophthalmol ; 38(4): 1741-1746, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28620705

RESUMO

PURPOSE: To report the results of long-term topical treatment with bevacizumab (Avastin) 5 mg/mL eyedrops in a case of aniridia-related neovacularization of the cornea. METHODS: Interventional case report. A female patient with aniridia had a decrease in the best corrected visual acuity from 0.32 to 0.02 in the OS over the course of 4 years, secondary to central corneal neovascularization and epithelial breakdown. Vision in the OD was 0.2. In 2008, at age 28, a shared decision was made to start off-label treatment with bevacizumab eyedrops 0.5% in both eyes. After 9 years, the visual acuity in the OD remained stable, with stability of the macropannus and maintenance of central corneal clarity. In the OS, the central corneal neovascularization regressed, the epithelium regained its clarity, and after cataract surgery visual acuity was regained to 0.32. RESULTS: After 9 years of treatment with topical bevacizumab, vision acuity is comparable to the situation of 12 years previously: Visual acuity remained stable in the ODS. CONCLUSION: In a young patient with progressive corneal neovascularization secondary to aniridia, stability of central corneal neovascularization was obtained and corneal clarity was preserved by adding a daily drop of bevacizumab 5 mg/mL. No adverse events occurred. Vessel growth was inhibited, and as such, the progression of the natural history of the patient's disease was halted. More clinical study with longer follow-up is needed to investigate the applicability of treatment with topical VEGF inhibitors in aniridia.


Assuntos
Inibidores da Angiogênese/administração & dosagem , Aniridia/complicações , Bevacizumab/administração & dosagem , Neovascularização da Córnea/tratamento farmacológico , Administração Tópica , Adulto , Feminino , Humanos , Resultado do Tratamento
6.
J Cataract Refract Surg ; 43(7): 909-914, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28823437

RESUMO

PURPOSE: To describe the refraction and visual acuity outcomes of multifocal intraocular lens (IOL) implantation in patients with previous corneal refractive laser surgery for myopia. SETTING: Academic Medical Center, University of Amsterdam, Amsterdam, and Retina Total Eye Care, Driebergen, the Netherlands. DESIGN: Retrospective cohort study. METHODS: The 3-month results after implantation of a multifocal IOL (Acrysof Restor) in patients who had corneal refractive laser surgery for myopia were analyzed. The primary outcome measures were corrected distance visual acuity, uncorrected distance visual acuity (UDVA), and refraction. The secondary outcome measures were number of laser enhancements, corneal irregularity, pre-laser magnitude of myopia, and posterior capsule opacification (PCO) rate. RESULTS: Seventy-seven eyes of 43 patients were included. Twenty-nine eyes had lens extraction because of cataract, and 48 eyes had a refractive lens exchange. The mean postoperative UDVA was 0.14 logarithm of minimum angle of resolution ± 0.22 (SD). The mean postoperative spherical equivalent was -0.38 ± 0.78 diopter (D). Fifty-seven percent of eyes were within ±0.50 D of emmetropia, and 86% were within ±1.0 D. Sixteen eyes (20.8%) had laser enhancement because of residual refraction. Fourteen eyes (18.2%) had a neodymium:YAG laser capsulotomy because of PCO. Eyes with pre-laser myopia greater than 6.0 D had a less predictable outcome than eyes with pre-laser myopia less than 6.0 D (P = .026). CONCLUSIONS: Multifocal IOL implantation after corneal refractive laser surgery for myopia resulted in good visual acuity and refraction. Results were less predictable with myopia greater than 6.0 D.


Assuntos
Extração de Catarata , Ceratomileuse Assistida por Excimer Laser In Situ , Implante de Lente Intraocular , Lentes Intraoculares Multifocais , Miopia , Córnea/cirurgia , Humanos , Cristalino , Miopia/cirurgia , Refração Ocular , Estudos Retrospectivos , Acuidade Visual
7.
Eur J Ophthalmol ; 27(2): 122-128, 2017 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-27791253

RESUMO

PURPOSE: To evaluate and compare the efficacy of a lipid-based lubricant eyedrop formulation (hydroxypropyl guar/propylene glycol/phospholipid [HPG/PG/PL]) with preservative-free saline for the treatment of dry eye. METHODS: This was a prospective, multicenter, randomized, single-masked, parallel-group phase 4 clinical study. Patients ≥18 years diagnosed with dry eye received 1 drop of saline 4 times daily (QID) for 15 days during a run-in phase, followed by randomization. Patients then instilled HPG/PG/PL or saline QID through day 35 and as needed through day 90. Change in tear film break-up time (TFBUT), change in total ocular surface staining (TOSS) score, and Impact of Dry Eye on Everyday Life (IDEEL) were evaluated on day 35. RESULTS: Increase in TFBUT from baseline to day 35 was assessed during the interim and final analyses. Mean ± SE difference between the HPG/PG/PL (n = 110) and saline groups (n = 100) was 1.3 ± 0.4 seconds (interim analysis; 95% confidence interval [CI] 0.5-2.1 seconds; p = 0.0012) and 1.0 ± 0.3 seconds (final analysis; 95% CI 0.4-1.6 seconds; p = 0.0011), demonstrating the superiority of HPG/PG/PL. The mean ± SE difference between the HPG/PG/PL and saline groups for IDEEL treatment effectiveness scores was 16.0 ± 3.6 (95% CI 8.9-23.1; p<0.0001). No significant differences in TOSS scores or IDEEL inconvenience scores were observed between treatment groups. CONCLUSIONS: Thirty-five days of QID HPG/PG/PL treatment resulted in a statistically significant improvement in TFBUT and IDEEL treatment effectiveness scores compared with saline but not in TOSS or IDEEL treatment inconvenience scores. HPG/PG/PL was well-tolerated by patients.


Assuntos
Síndromes do Olho Seco/tratamento farmacológico , Lipídeos/deficiência , Lubrificantes Oftálmicos/administração & dosagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Síndromes do Olho Seco/fisiopatologia , Síndromes do Olho Seco/psicologia , Emulsões , Feminino , Humanos , Lubrificantes Oftálmicos/química , Masculino , Pessoa de Meia-Idade , Fosfatidilgliceróis/administração & dosagem , Fosfatidilgliceróis/química , Polissacarídeos/administração & dosagem , Polissacarídeos/química , Conservantes Farmacêuticos , Propilenoglicol/administração & dosagem , Propilenoglicol/química , Estudos Prospectivos , Qualidade de Vida/psicologia , Método Simples-Cego , Lágrimas/fisiologia , Resultado do Tratamento , Adulto Jovem
8.
J Refract Surg ; 31(11): 746-51, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26544562

RESUMO

PURPOSE: To evaluate differences in straylight between eyes implanted with a hydrophilic multifocal IOL (Seelens MF; Hanita Lenses, Hanita, Israel) and a hydrophobic multifocal IOL (SN6AD1; Alcon Laboratories, Inc., Fort Worth, TX). METHODS: In a prospective cohort study, routinely obtained straylight measurements (C-Quant; Oculus Optikgeräte, Wetzlar, Germany) 3 months after standard phacoemulsification for either cataract or refractive lens procedures were compared. Patients were implanted with either the SeeLens MF IOL or the SN6AD1 IOL. Postoperative straylight values, visual acuity, and refractive outcomes were compared. RESULTS: The SeeLens MF IOL was implanted in 84 eyes and the SN6AD1 IOL in 79 eyes. The difference in straylight was 0.08 (P = .01), with the SeeLens MF IOL having less straylight. Postoperative CDVA was logMAR -0.03 ± 0.06 in the SeeLens MF group, and logMAR -0.02 ± 0.08 in the SN6AD1 group. Mean postoperative refraction was +0.01 ± 0.43 and +0.06 ± 0.35 D, respectively. CONCLUSIONS: The Seelens MF IOL showed a stray-light of log(s) 0.08 lower than the SN6AD1 IOL. In terms of spherical equivalent and visual acuity the lenses performed equally. More study will aid in understanding the causes and clinical impact of this difference.


Assuntos
Ofuscação , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Espalhamento de Radiação , Transtornos da Visão/diagnóstico , Idoso , Avaliação da Deficiência , Feminino , Humanos , Luz , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Pseudofacia/fisiopatologia , Acuidade Visual/fisiologia
9.
Cornea ; 34(11): 1375-7, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26312617

RESUMO

PURPOSE: To report the incidence of opacification of the intraocular lens (IOL) after Descemet stripping endothelial keratoplasty (DSEK) in an academic ophthalmology clinic. METHODS: In this retrospective case series, all patients who underwent DSEK between 2003 and 2013 were included. In 2008, the first patient presented with reduced vision as a result of opacification of the IOL in our clinic. The period between DSEK surgery and diagnosis of IOL opacification, Snellen corrected distance visual acuity before and after the appearance of IOL opacification, IOL specifications, and incidence of IOL exchange were assessed. RESULTS: A total of 160 eyes were operated on. Opacification was seen in 8 eyes (5%) and was diagnosed between 4 and 24 months after DSEK (mean, 9.6; SD, 6.3; range, 4-24 months). The mean Snellen corrected distance visual acuity was 0.6 (SD, 0.2; range, 0.2-0.8) before opacification and 0.3 (SD, 0.2; range, 0.02-0.6) after opacification of the IOL occurred. The IOL material was hydrophilic acrylic in all patients. In 4 eyes, IOL exchange was performed. CONCLUSIONS: Opacification of the IOL can be a vision-threatening late complication after DSEK and was seen in 8 of 160 eyes.


Assuntos
Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/efeitos adversos , Lentes Intraoculares , Complicações Pós-Operatórias , Falha de Prótese/etiologia , Distrofia Endotelial de Fuchs/fisiopatologia , Distrofia Endotelial de Fuchs/cirurgia , Humanos , Incidência , Pseudofacia/fisiopatologia , Estudos Retrospectivos , Transtornos da Visão/etiologia , Transtornos da Visão/fisiopatologia , Acuidade Visual/fisiologia
10.
J Refract Surg ; 31(5): 342-5, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25974975

RESUMO

PURPOSE: To present two cases with complications after Nd:YAG laser treatment of epithelial ingrowth. METHODS: Case reports. RESULTS: Dense central recurrent epithelial ingrowth was treated with a Nd:YAG laser directed at the epithelial nests in the LASIK flap interface in one case. Misalignment of the aiming beam after movement resulted in perforation of the LASIK flap, followed by renewed epithelial ingrowth through the new defect. The epithelial ingrowth receded and became more translucent as a result of the treatment, but the area of the perforation remained irregular. In another case, use of the Nd:YAG laser to treat recurrent epithelial ingrowth adjacent to the flap edge created a cavitation bubble that broke through the flap edge, creating a new epithelial channel through which ingrowth recurred. CONCLUSIONS: Surface breakthrough and renewed epithelial ingrowth is a possible complication of Nd:YAG laser treatment of epithelial ingrowth.


Assuntos
Doenças da Córnea/cirurgia , Epitélio Corneano/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Lasers de Estado Sólido/efeitos adversos , Microbolhas , Retalhos Cirúrgicos/patologia , Adulto , Antibacterianos/uso terapêutico , Cloranfenicol/uso terapêutico , Doenças da Córnea/tratamento farmacológico , Doenças da Córnea/etiologia , Dexametasona/uso terapêutico , Quimioterapia Combinada , Epitélio Corneano/efeitos dos fármacos , Epitélio Corneano/patologia , Feminino , Glucocorticoides/uso terapêutico , Humanos , Recidiva , Acuidade Visual
11.
J Cataract Refract Surg ; 40(5): 748-55, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24631202

RESUMO

PURPOSE: To report the outcomes of changes in straylight before and after phacoemulsification in eyes with preoperative corrected distance visual acuity (CDVA) better than 0.1 logMAR. SETTING: Private refractive surgery clinic, Driebergen, the Netherlands. DESIGN: Cohort study. METHODS: Standard phacoemulsification with implantation of a monofocal or multifocal intraocular lens (IOL) was performed. Preoperative and 3-month postoperative straylight values, CDVA, and refractive error were compared. RESULTS: The study enrolled 160 eyes (89 patients). The mean CDVA was 0.02 ± 0.05 logMAR (range -0.1 to 0.1 logMAR) preoperatively and 0.00 ± 0.04 logMAR (range -0.1 to 0.2 logMAR) postoperatively. The mean preoperative straylight was 1.21 ± 0.20 log(s) (range 0.80 to 1.74 log[s]) and 1.11 ± 1.16 log(s) (range 0.76 to 1.63 log[s]), respectively; the improvement was statistically significant. There was a correlation between high preoperative straylight values and postoperative improvement in straylight values. CONCLUSIONS: In eyes with relatively good CDVA of 0.1 logMAR or better (decimal 0.8 or better; Snellen 20/25 or better), straylight improved by 0.10 log(s) after cataract surgery. A subgroup of 44 eyes had an improvement of more than 0.20 log(s), which is comparable to a 2-line improvement on the vision chart.


Assuntos
Catarata/fisiopatologia , Ofuscação , Implante de Lente Intraocular , Facoemulsificação , Transtornos da Visão/fisiopatologia , Acuidade Visual/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Luz , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
12.
J Refract Surg ; 30(1): 54-61, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24168790

RESUMO

PURPOSE: To review the spectrum of disease, symptomatology, and management offered to patients referred for a second opinion after refractive surgery. METHODS: A prospective cohort study was done on all patients referred from October 1, 2006, to September 30, 2011, to a tertiary eye clinic after refractive surgery of any kind (ie, corneal laser surgery, conductive keratoplasty, radial keratotomy, phakic implants, refractive lens exchanges, or any combination thereof). Data analysis was performed on all demographic and clinical aspects of this cohort, including the initial complaint, type of referral, number of complaints, procedure previously performed, diagnosis at our center, type of advice given, and rate and type of surgical intervention. RESULTS: One hundred thirty-one eyes (69 patients) were included. Corneal refractive surgery was performed in 82% (108 eyes), and 11% (14 eyes) were seen after phakic intraocular lens (PIOL) implantation and 7% (9 eyes) after refractive lens exchange. The most common diagnoses were tear film dysfunction (30 eyes, 23%), residual refractive error (25 eyes, 19%), and cataract (20 eyes, 15%). Most patients (42 patients, 61%) were treated conservatively. In 27 patients (39%), 36 eyes (28%) were managed surgically. Severe visual loss was seen in 1 eye. CONCLUSIONS: No major problems were found in most second opinions after refractive surgery referral. Dry eyes, small residual refractive error, or higher-order aberrations were the most common complaints. Surgical intervention was needed in 36 eyes (28%), almost half of which were cataract extractions. Severe visual loss was seen in 1 eye with a PIOL. There was no incidence of severe visual loss in keratorefractive and refractive lens exchange procedures.


Assuntos
Oftalmopatias/diagnóstico , Encaminhamento e Consulta/estatística & dados numéricos , Procedimentos Cirúrgicos Refrativos/estatística & dados numéricos , Centros de Atenção Terciária/estatística & dados numéricos , Transtornos da Visão/reabilitação , Adulto , Idoso , Catarata/diagnóstico , Catarata/terapia , Estudos de Coortes , Oftalmopatias/terapia , Feminino , Glaucoma/diagnóstico , Glaucoma/terapia , Humanos , Doenças do Aparelho Lacrimal/diagnóstico , Doenças do Aparelho Lacrimal/terapia , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Lentes Intraoculares Fácicas , Estudos Prospectivos , Erros de Refração/diagnóstico , Erros de Refração/terapia , Resultado do Tratamento , Acuidade Visual/fisiologia
13.
J Cataract Refract Surg ; 39(5): 799-803, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23541897

RESUMO

We describe the case of an 83-year-old woman who had uneventful phacoemulsification with implantation of a tripod hydrophilic acrylic intraocular lens (IOL). Because of postoperative corneal decompensation, 2 Descemet-stripping endothelial keratoplasty (DSEK) procedures were performed within 2 years. After the second procedure, the graft was not well attached, requiring an intracameral injection of air on day 3. Approximately 9 months later, opacification was observed on the anterior surface of the IOL, with a significant decrease in visual acuity. The IOL was explanted within the capsular bag. Laboratory analyses revealed granular deposits densely distributed in a round pattern within the margins of the capsulorhexis. Granules were located at the anterior surface/subsurface of the IOL and stained positive for calcium (alizarin red and von Kossa method). Scheimpflug photography revealed high levels of light scattering from the opacified area. Surgeons should be aware of possible localized calcification following DSEK procedures in pseudophakic patients with hydrophilic acrylic IOLs.


Assuntos
Calcinose/etiologia , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/efeitos adversos , Lentes Intraoculares , Falha de Prótese/etiologia , Resinas Acrílicas , Idoso de 80 Anos ou mais , Calcinose/metabolismo , Cálcio/metabolismo , Remoção de Dispositivo , Feminino , Humanos , Interações Hidrofóbicas e Hidrofílicas , Implante de Lente Intraocular , Luz , Facoemulsificação , Reoperação , Espalhamento de Radiação , Acuidade Visual
14.
J Cataract Refract Surg ; 39(4): 642-4, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23522586

RESUMO

We report a case of in-the-bag decentration and tilt of a hydrophilic rotationally asymmetric multifocal intraocular lens (IOL) of the M Plus type secondary to capsule contraction. After uneventful surgery and follow-up for 3 months, progressive decentering and tilting of the IOL secondary to capsule contraction and capsulorhexis phimosis was noticed. A surgical procedure was necessary to restore correct centration of the IOL. The uncorrected distance and near visual acuities were restored to logMAR 0. Hydrophilic multifocal IOLs of this specific design may be sensitive to postoperative decentration. Capsular tension rings may alleviate the problem in a secondary repair procedure. The softness of the C-loop haptics of this IOL type may also play a role in the decentration.


Assuntos
Migração do Implante de Lente Intraocular/etiologia , Contratura/complicações , Cápsula do Cristalino/patologia , Doenças do Cristalino/complicações , Lentes Intraoculares , Idoso , Migração do Implante de Lente Intraocular/cirurgia , Contratura/cirurgia , Humanos , Cápsula do Cristalino/cirurgia , Doenças do Cristalino/cirurgia , Masculino , Reoperação , Acuidade Visual
15.
Acta Ophthalmol ; 91(5): 418-24, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23106951

RESUMO

PURPOSE: The purpose of this study was to model the influence of cataract on Spectral Domain Optical Coherence Tomography (SDOCT) image quality and Retinal Nerve Fibre Layer (RNFL) thickness measurements. METHODS: SDOCT images, made with two different devices (3DOCT-1000, Topcon and Cirrus HD-OCT), before and after cataract surgery were compared and judged against measurements from normal subjects using artificial filters simulating the effects of cataract. Optical density of the images was calculated based on a mathematical model described previously. RESULTS: In total, forty-eight eyes were included for pre- and postoperative cataract extraction measurements. OCT image quality significantly (p < 0.001) improved postoperative and postoperative RNFL thickness was significantly (p < 0.001) thicker in both groups of patients. The measurements using artificial filters showed a rather precise linear relation between change in filter induced optical density and change in RNFL thickness (R = 0.941, p < 0.001 for 3DOCT-1000 and R = 0.785, p < 0.001 for Cirrus HD-OCT). For the patient groups, the relation was less marked, 3DOCT-1000 Rs = 0.697, p < 0.03 and Cirrus HD-OCT Rs = 0.444, p < 0.03. The predictive potential based on the found linear relationship between OCT-effective optical density of cataract and the cataract-induced underestimation was however limited, and mean difference ± SD between predicted and measured RNFL thickness were 1.68 ± 7.55 (3DOCT-1000) and 3.71 ± 2.97 (Cirrus HD-OCT) micron. CONCLUSIONS: A linear relationship exists between OCT-effective optical density of cataract and underestimation of RNFL thickness measured with OCT. This finding holds promise to correct for cataract-induced changes in RNFL measurements, but will differ for each type of OCT device.


Assuntos
Algoritmos , Catarata/patologia , Cristalino , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Idoso , Extração de Catarata , Feminino , Humanos , Masculino , Período Pós-Operatório , Período Pré-Operatório
16.
Int Ophthalmol ; 33(2): 147-51, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23129504

RESUMO

To assess the incidence of elevated intraocular pressure (IOP) after descemet stripping endothelial keratoplasty (DSEK). Retrospective case series. From the start of the technique in our hospital in 2003 until the middle of 2010, 73 eyes underwent DSEK, of which 66 (90.5 %) had a clear graft 1 year after surgery. IOP data pre- and postoperatively were analyzed. Follow-up was 1-5 years (mean 3.8, SD 1.3). Mean age was 71 years (SD 11, range 43-89). Three eyes (4.5 %) had a history of glaucoma before DSEK. Mean pre-operative IOP was 12.4 mmHg (SD ± 4.3). Mean IOP 1 day post-operatively was 16.4 mmHg (±9.2). Mean IOP after 1 and 6 months, and 1, 3, and 5 years were, respectively, 13.9 (±5.3), 14.7 (±5.6), 14.2 (±5.4), 13.8 (±3.7), and 12.6 (±3.5). Seventeen percent (11 eyes) had a postoperative rise in IOP which needed medical or surgical intervention: 8 % (5 eyes) had a rise in IOP 1 day after DSEK, of which 1 underwent a trabeculectomy 7 months after DSEK surgery; 6 % (4 eyes) had a rise in IOP later in the postoperative period, which could all be managed medically; and 3 % (2 eyes) had increased IOP 1 day after DSEK and later in the postoperative period, both eyes underwent a trabeculectomy 5 and 24 months, respectively, after DSEK surgery. An increase in IOP was encountered in 17 % of DSEK patients. Checking the IOP in the short and long postoperative period is necessary.


Assuntos
Doenças da Córnea/epidemiologia , Doenças da Córnea/cirurgia , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/efeitos adversos , Pressão Intraocular , Hipertensão Ocular/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/etiologia , Hipertensão Ocular/cirurgia , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Tonometria Ocular , Trabeculectomia
17.
J Refract Surg ; 28(8): 545-50, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22869233

RESUMO

PURPOSE: To evaluate the effect on refraction of neodymium:YAG (Nd:YAG) laser posterior capsulotomy for posterior capsule opacification (PCO), and to evaluate the correlation between automated and subjective refraction in multifocal apodized diffractive pseudophakia. METHODS: A retrospective study of 75 pseudophakic eyes (50 patients) with multifocal apodized diffractive pseudophakia, treated for PCO with Nd:YAG laser posterior capsulotomy, was performed. Pre- and postintervention values of refractive and visual parameters were compared. The outcomes of autorefraction and subjective refraction were also compared. RESULTS: Uncorrected and corrected distance visual acuity improved significantly after Nd:YAG capsulotomy (P<.001). No significant changes were noted in defocus equivalent, astigmatic power vectors J(0) and J(45), and overall blurring strength in subjective refraction and autorefraction. Spherical equivalent changed significantly in autorefraction (P=.008), but not in subjective refraction. Autorefraction and subjective refraction were highly correlated in spherical equivalent, defocus equivalent, and blurring strength (r(2)>0.59). In approximately 7% of eyes, a change of more than 0.50 diopters in spherical equivalent in subjective refraction occurred. CONCLUSIONS: In most cases, Nd:YAG laser capsulotomy in patients with multifocal pseudophakia did not result in a change in refraction. However, 7% of eyes experienced a significant change in subjective refraction. Autorefraction correlated well with subjective refraction in apodized diffractive multifocal IOLs.


Assuntos
Opacificação da Cápsula/cirurgia , Terapia a Laser , Lasers de Estado Sólido/uso terapêutico , Cápsula Posterior do Cristalino/cirurgia , Pseudofacia/cirurgia , Refração Ocular/fisiologia , Idoso , Feminino , Humanos , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Pseudofacia/fisiopatologia , Estudos Retrospectivos , Acuidade Visual/fisiologia
18.
J Cataract Refract Surg ; 38(5): 840-8, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22520308

RESUMO

PURPOSE: To assess adding straylight measurements to the indication for cataract surgery. SETTING: Onze Lieve Vrouwe Hospital, Amsterdam, and Zonnestraal Eye Clinic, Hilversum, The Netherlands. DESIGN: Prospective interventional cohort study. METHODS: Before and after cataract extraction, corrected distance visual acuity (CDVA) and straylight were recorded in all patients. Subjective complaints were documented by the 39-item National Eye Institute Visual Function Questionnaire (NEI VFQ-39) and a straylight questionnaire. RESULTS: The population comprised 217 patients with a mean age of 72 years ± 9.12 (SD) (range 29 to 90 years). Preoperatively, the mean straylight was 1.55 ± 0.29 log(s) and the mean CDVA, 0.28 ± 0.21 logMAR. Visual acuity and straylight showed little correlation (R(2) = 0.08). The mean postoperative improvement in CDVA was 0.26 ± 0.20 logMAR (range -0.12 to 1.12 logMAR) and in straylight, 0.31 ± 0.32 log(s) (range -0.50 to 1.27 log[s]). The preoperative breakeven point (50% chance of postoperative improvement) was 0.06 logMAR for CDVA and 1.29 log(s) for straylight. Preoperative and postoperative questionnaires showed straylight had almost the same influence as visual acuity on quality of vision. CONCLUSIONS: Straylight and visual acuity measure different aspects of quality of vision and influenced subjective visual quality almost equally. When straylight was added to preoperative considerations of cataract extraction, postoperative results were more predictable. FINANCIAL DISCLOSURE: The Netherlands Academy of Arts and Sciences has a proprietary interest in the C-Quant Straylight meter. No author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Extração de Catarata , Catarata/diagnóstico , Ofuscação , Espalhamento de Radiação , Acuidade Visual/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Catarata/fisiopatologia , Técnicas de Diagnóstico Oftalmológico , Avaliação da Deficiência , Procedimentos Cirúrgicos Eletivos , Feminino , Nível de Saúde , Humanos , Luz , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Perfil de Impacto da Doença , Inquéritos e Questionários
19.
Cornea ; 31(4): 380-6, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22262226

RESUMO

PURPOSE: Long-term quality of vision after Descemet stripping endothelial keratoplasty (DSEK) was evaluated and correlated with corneal characteristics and subjective complaints. METHODS: Thirty-four eyes were examined; patients had a single visit 6 to 64 months after DSEK for Fuchs dystrophy. Best-corrected distance acuity (BCDA) and straylight were analyzed. To better evaluate long-term postoperative BCDA changes, longitudinal data were used from earlier visits. Corneal thickness was measured with the Visante anterior segment optical coherence tomography. Interface, stromal, and endothelial haze were semiquantitatively graded using the slit lamp. Vision-related quality of life was evaluated with the 39-item National Eye Institute Visual Function Questionnaire and a straylight questionnaire. Correlation analysis comparing corneal characteristics with visual quality was performed. RESULTS: Mean postoperative time was 1027 ± 453 days. Mean BCDA at this time was 0.33 ± 0.19 logarithm of the minimal angle of resolution. BCDA remained stable with long-term postoperative follow-up. Straylight averaged 1.47 ± 0.19, on average 0.12 log units higher than normal for age-related pseudophakic eyes (P < 0.001). BCDA correlated with corneal haze (r = 0.50), whereas straylight showed a nonsignificant association (P = 0.12). Neither BCDA nor straylight correlated with corneal thickness. Mean Visual Function Questionnaire 39 score was 77/100, and mean score of the straylight questionnaire was 46/100. CONCLUSION: Quality of vision after DSEK does not return to normal levels of age-matched pseudophakic eyes, with decreased BCDA and increased straylight. Questionnaire scores indicate mild (Visual Function Questionnaire 39) to moderate (straylight) subjective visual impairment. Corneal thickness and haze do not offer an adequate explanation for the decreased visual quality.


Assuntos
Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Ofuscação , Qualidade de Vida , Espalhamento de Radiação , Acuidade Visual/fisiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Distrofia Endotelial de Fuchs/cirurgia , Humanos , Luz , Masculino , Pessoa de Meia-Idade , Perfil de Impacto da Doença , Inquéritos e Questionários , Tomografia de Coerência Óptica
20.
Cornea ; 31(10): 1189-92, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22236784

RESUMO

PURPOSE: To report 3 cases of unexplained intraocular lens (IOL) opacification in patients who previously underwent Descemet stripping endothelial keratoplasty (DSEK). METHODS: Case series. Three pseudophakic eyes of 3 patients, who developed a membraneous opacification of the IOL after uneventful DSEK are presented. RESULTS: In 2 eyes, the opacification interfered with visual acuity. In 1 case, an attempt was made to remove the opacification with the aid of YAG laser and surgically, to no avail, necessitating an IOL explantation. CONCLUSIONS: IOL opacification can occur in eyes previously subjected to DSEK. The majority of patients subjected to DSEK are pseudophakic; surgeons should be aware of this possible complication. To the best of our knowledge, this has not been described in the literature to date. Further research is required to elucidate the nature of such IOL opacifications and possible ways to prevent them.


Assuntos
Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Lentes Intraoculares , Complicações Pós-Operatórias , Falha de Prótese , Idoso , Remoção de Dispositivo , Feminino , Humanos , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Reoperação , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA