1.
J Oral Maxillofac Surg ; 81(9): 1176-1185, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37315925

RESUMO

BACKGROUND: 3D-printed patient-specific anatomical models are becoming an increasingly popular tool for planning reconstructive surgeries to treat oral cancer. Currently there is a lack of information regarding model accuracy, and how the resolution of the computed tomography (CT) scan affects the accuracy of the final model. PURPOSE: The primary objective of this study was to determine the CT z-axis resolution necessary in creating a patient specific mandibular model with clinically acceptable accuracy for global bony reconstruction. This study also sought to evaluate the effect of the digital sculpting and 3D printing process on model accuracy. STUDY DESIGN: This was a cross-sectional study using cadaveric heads obtained from the Ohio State University Body Donation Program. INDEPENDENT VARIABLES: The first independent variable is CT scan slice thickness of either 0.675 , 1.25, 3.00, or 5.00 mm. The second independent variable is the three produced models for analysis (unsculpted, digitally sculpted, 3D printed). MAIN OUTCOME VARIABLE: The degree of accuracy of a model as defined by the root mean square (RMS) value, a measure of a model's discrepancy from its respective cadaveric anatomy. ANALYSES: All models were digitally compared to their cadaveric bony anatomy using a metrology surface scan of the dissected mandible. The RMS value of each comparison evaluates the level of discrepancy. One-way ANOVA tests (P < .05) were used to determine statistically significant differences between CT scan resolutions. Two-way ANOVA tests (P < .05) were used to determine statistically significant differences between groups. RESULTS: CT scans acquired for 8 formalin-fixed cadaver heads were processed and analyzed. The RMS for digitally sculpted models decreased as slice thickness decreased, confirming that higher resolution CT scans resulted in statistically more accurate model production when compared to the cadaveric gold standard. Furthermore, digitally sculpted models were significantly more accurate than unsculpted models (P < .05) at each slice thickness. CONCLUSIONS: Our study demonstrated that CT scans with slice thicknesses of 3.00 mm or smaller created statistically significantly more accurate models than models created from slice thicknesses of 5.00 mm. The digital sculpting process statistically significantly increased the accuracy of models and no loss of accuracy through the 3D printing process was observed.


Assuntos
Modelos Anatômicos , Tomografia Computadorizada por Raios X , Humanos , Estudos Transversais , Tomografia Computadorizada por Raios X/métodos , Mandíbula/diagnóstico por imagem , Cadáver
2.
Oral Oncol ; 132: 105976, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35809506

RESUMO

Microvascular free flap reconstruction has remained the standard of care in reconstruction of large tissue defects following ablative head and neck oncologic surgery, especially for bony structures. Computer aided design/computer assisted manufacturing (CAD/CAM) and 3-dimensionally (3D) printed models and devices offer novel solutions for reconstruction of bony defects. Conventional free hand techniques have been enhanced using 3D printed anatomic models for reference and pre-bending of titanium reconstructive plates, which has dramatically improved intraoperative and microvascular ischemia times. Improvements led to current state of the art uses which include full virtual planning (VP), 3D printed osteotomy guides, and patient specific reconstructive plates, with advanced options incorporating dental rehabilitation and titanium bone replacements into the primary surgical plan through use of these tools. Limitations such as high costs and delays in device manufacturing may be mitigated with in house software and workflows. Future innovations still in development include printing custom prosthetics, 'bioprinting' of tissue engineered scaffolds, integration of therapeutic implants, and other possibilities as this technology continues to rapidly advance. This review summarizes the literature and serves as a summary guide to the historic, current, advanced, and future possibilities of 3D printing within head and neck oncologic surgery and bony reconstruction. This review serves as a summary guide to the historic, current, advanced, and future roles of CAD/CAM and 3D printing within the field of head and neck oncologic surgery and bony reconstruction.


Assuntos
Procedimentos de Cirurgia Plástica , Cirurgia Assistida por Computador , Desenho Assistido por Computador , Humanos , Modelos Anatômicos , Impressão Tridimensional , Procedimentos de Cirurgia Plástica/métodos , Cirurgia Assistida por Computador/métodos , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA