Resultados 1 - 20 de 991
Filtrar
1.
Med Phys ; 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38977285

RESUMO

BACKGROUND: The dynamic collimation system (DCS) provides energy layer-specific collimation for pencil beam scanning (PBS) proton therapy using two pairs of orthogonal nickel trimmer blades. While excellent measurement-to-calculation agreement has been demonstrated for simple cube-shaped DCS-trimmed dose distributions, no comparison of measurement and dose calculation has been made for patient-specific treatment plans. PURPOSE: To validate a patient-specific quality assurance (PSQA) process for DCS-trimmed PBS treatment plans and evaluate the agreement between measured and calculated dose distributions. METHODS: Three intracranial patient cases were considered. Standard uncollimated PBS and DCS-collimated treatment plans were generated for each patient using the Astroid treatment planning system (TPS). Plans were recalculated in a water phantom and delivered at the Miami Cancer Institute (MCI) using an Ion Beam Applications (IBA) dedicated nozzle system and prototype DCS. Planar dose measurements were acquired at two depths within low-gradient regions of the target volume using an IBA MatriXX ion chamber array. RESULTS: Measured and calculated dose distributions were compared using 2D gamma analysis with 3%/3 mm criteria and low dose threshold of 10% of the maximum dose. Median gamma pass rates across all plans and measurement depths were 99.0% (PBS) and 98.3% (DCS), with a minimum gamma pass rate of 88.5% (PBS) and 91.2% (DCS). CONCLUSIONS: The PSQA process has been validated and experimentally verified for DCS-collimated PBS. Dosimetric agreement between the measured and calculated doses was demonstrated to be similar for DCS-collimated PBS to that achievable with noncollimated PBS.

2.
Med Phys ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38860497

RESUMO

BACKGROUND: Ultra-high dose rate radiotherapy (UHDR-RT) has demonstrated normal tissue sparing capabilities, termed the FLASH effect; however, available dosimetry tools make it challenging to characterize the UHDR beams with sufficiently high concurrent spatial and temporal resolution. Novel dosimeters are needed for safe clinical implementation and improved understanding of the effect of UHDR-RT. PURPOSE: Ultra-fast scintillation imaging has been shown to provide a unique tool for spatio-temporal dosimetry of conventional cyclotron pencil beam scanning (PBS) deliveries, indicating the potential use for characterization of UHDR PBS proton beams. The goal of this work is to introduce this novel concept and demonstrate its capabilities in recording high-resolution dose rate maps at FLASH-capable proton beam currents, as compared to log-based dose rate calculation, internally developed UHDR beam simulation, and a fast point detector (EDGE diode). METHODS: The light response of a scintillator sheet located at isocenter and irradiated by PBS proton fields (40-210 nA, 250 MeV) was imaged by an ultra-fast iCMOS camera at 4.5-12 kHz sampling frequency. Camera sensor and image intensifier gain were optimized to maximize the dynamic range; the camera acquisition rate was also varied to evaluate the optimal sampling frequency. Large field delivery enabled flat field acquisition for evaluation of system response homogeneity. Image intensity was calibrated to dose with film and the recorded spatio-temporal data was compared to a PPC05 ion chamber, log-based reconstruction, and EDGE diode. Dose and dose rate linearity studies were performed to evaluate agreement under various beam conditions. Calculation of full-field mean and PBS dose rate maps were calculated to highlight the importance of high resolution, full-field information in UHDR studies. RESULTS: Camera response was linear with dose (R2 = 0.997) and current (R22 = 0.98) in the range from 2-22 Gy and 40-210 nA, respectively, when compared to ion chamber readings. The deviation of total irradiation time calculated with the imaging system from the log file recordings decreased from 0.07% to 0.03% when imaging at 12 kfps versus 4.5 kfps. Planned and delivered spot positions agreed within 0.2 ± $\pm$ 0.1 mm and total irradiation time agreed within 0.2 ± $\pm$ 0.2 ms when compared with the log files, indicating the high concurrent spatial and temporal resolution. For all deliveries, the PBS dose rate measured at the diode location agreed between the imaging and the diode within 3% ± $\pm$ 2% and with the simulation within 5% ± $\pm$ 3% CONCLUSIONS: Full-field mapping of dose and dose rate is imperative for complete understanding of UHDR PBS proton dose delivery. The high linearity and various spatiotemporal metric reporting capabilities confirm the continued use of this camera system for UHDR beam characterization, especially for spatially resolved dose rate information.

3.
Phys Med Biol ; 69(13)2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38862000

RESUMO

Objective.In proton pencil beam scanning (PBS) continuous delivery, the beam is continuously delivered without interruptions between spots. For synchrotron-based systems, the extracted beam current exhibits a spill structure, and recent publications on beam current measurements have demonstrated significant fluctuations around the nominal values. These fluctuations potentially lead to dose deviations from those calculated assuming a stable beam current. This study investigated the dosimetric implications of such beam current fluctuations during proton PBS continuous scanning.Approach.Using representative clinical proton PBS plans, we performed simulations to mimic a worst-case clinical delivery environment with beam current varies from 50% to 250% of the nominal values. The simulations used the beam delivery parameters optimized for the best beam delivery efficiency of the upcoming particle therapy system at Mayo Clinic Florida. We reconstructed the simulated delivered dose distributions and evaluated the dosimetric impact of beam current fluctuations.Main results.Despite significant beam current fluctuations resulting in deviations at each spot level, the overall dose distributions were nearly identical to those assuming a stable beam current. The 1 mm/1% Gamma passing rate was 100% for all plans. Less than 0.2% root mean square error was observed in the planning target volume dose-volume histogram. Minimal differences were observed in all dosimetric evaluation metrics.Significance.Our findings demonstrate that with our beam delivery system and clinical planning practice, while significant beam current fluctuations may result in large local move monitor unit deviations at each spot level, the overall impact on the dose distribution is minimal.


Assuntos
Terapia com Prótons , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Síncrotrons , Terapia com Prótons/métodos , Terapia com Prótons/instrumentação , Radiometria/instrumentação , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Método de Monte Carlo
4.
ACS Appl Mater Interfaces ; 16(25): 32045-32057, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38861701

RESUMO

Pioneering approaches for precise tumor removal involve fluorescence-guided surgery, while challenges persist, including the low fluorescence contrast observed at tumor boundaries and the potential for excessive damage to normal tissue at the edges. Lead/cadmium sulfide quantum dots (PbS@CdS QDs), boasting high quantum yields (QYs) and vivid fluorescence, have facilitated advancements in the second near-infrared window (NIR-II, 900-1700 nm). However, during fluorescent surgical navigation operations, hydrophilic coatings of these inorganic nanoparticles (NPs) guarantee biosafety; it also comes at the expense of losing a significant portion of QY and NIR-II fluorescence, causing heightened damage to normal tissues caused by cutting edges. Herein, we present hydrophilic core-shell PbS@CdS@PEG NPs with an exceptionally small diameter (∼8 nm) and a brilliant NIR-IIb (1500-1700 nm) emission at approximately 1600 nm. The mPEG-SH (MW: 2000) addresses the hydrophobicity and enhances the biosafety of PbS@CdS QDs. In vivo fluorescence-guided cervical tumor resection becomes achievable immediately upon injection of an aqueous solution of PbS@CdS@PEG NPs. Notably, this approach results in a significantly reduced thickness (100-500 µm) of damage to normal tissues at the margins of the resected tumors. With a high QY (∼30.2%) and robust resistance to photobleaching, NIR-IIb imaging is sustained throughout the imaging process.


Assuntos
Pontos Quânticos , Sulfetos , Pontos Quânticos/química , Animais , Humanos , Camundongos , Sulfetos/química , Feminino , Chumbo/química , Compostos de Cádmio/química , Cirurgia Assistida por Computador/métodos , Imagem Óptica , Fluorescência , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/cirurgia , Neoplasias do Colo do Útero/patologia , Camundongos Endogâmicos BALB C , Células HeLa
5.
Phys Med ; 122: 103380, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38805761

RESUMO

INTRODUCTION: Real-time gated proton therapy (RGPT) is a motion management technique unique to the Hitachi particle therapy system. It uses pulsed fluoroscopy to track an implanted fiducial marker. There are currently no published guidelines on how to conduct the commissioning and quality assurance. In this work we reported on our centre's commissioning workflow and our daily and monthly QA procedures. METHODS: Six commissioning measurements were designed for RGPT. The measurements include imaging qualities, fluoroscopic exposures, RGPT marker tracking accuracy, temporal gating latency, fiducial marker tracking fidelity and an end-to-end proton dosimetry measurement. Daily QA consists of one measurement on marker localization accuracy. Four months daily QA trends are presented. Monthly QA consists of three measurementson the gating latency, fluoroscopy imaging quality and dosimetry verification of gating operation with RGPT. RESULTS: The RGPT was successfully commissioned in our centre. The air kerma rates were within 15 % from specifications and the marker tracking accuracies were within 0.245 mm. The gating latencies for turning the proton beam on and off were 119.5 and 50.0 ms respectively. The 0.4x10.0 mm2 Gold AnchorTM gave the best tracking results with visibility up to 30 g/cm2. Gamma analysis showed that dose distribution of a moving and static detectors had a passing rate of more than 95 % at 3 %/3mm. The daily marker localization QA results were all less than 0.2 mm. CONCLUSION: This work could serve as a good reference for other upcoming Hitachi particle therapy centres who are interested to use RGPT as their motion management solution.


Assuntos
Terapia com Prótons , Garantia da Qualidade dos Cuidados de Saúde , Terapia com Prótons/instrumentação , Marcadores Fiduciais , Radiometria , Fatores de Tempo , Fluoroscopia , Controle de Qualidade , Humanos , Radioterapia Guiada por Imagem
6.
Materials (Basel) ; 17(10)2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38793363

RESUMO

Surgical ASTM F139 stainless steel is used for temporary fixtures in the biomedical field. Tribocorrosion is a major concern in this application. The aim of the present work was to study the interplay between tribocorrosion behavior and the surface chemistry of the ASTM F139 stainless steel in phosphate-buffered saline solution (PBS). Sliding wear tests were conducted against alumina balls at different electrochemical potentials: open circuit potential (OCP), cathodic potential (-100 mV versus the OCP), and anodic potentials (+200 mVAg/AgCl and +700 mVAg/AgCl). The normal load was 20 N. The wear volume was estimated based on micrographs obtained from the wear tracks using confocal laser scanning microscopy. Moreover, the wear tracks were also examined by scanning electron microscopy (SEM). The surface chemistry of the ASTM F139 specimens was analyzed by X-ray photoelectron spectroscopy (XPS). The wear volume was dependent on the electrochemical potential, being maximized at +700 mVAg/AgCl. Delamination areas and grooves were observed in the wear tracks. Detailed assessment of the surface chemistry inside the wear tracks allowed identification of the main chemical species and their relative quantities, thus enabling correlation of the passive film composition with the observed tribocorrosion behavior.

7.
J Appl Clin Med Phys ; 25(7): e14342, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38590112

RESUMO

BACKGROUND: Rescanning is a common technique used in proton pencil beam scanning to mitigate the interplay effect. Advances in machine operating parameters across different generations of particle therapy systems have led to improvements in beam delivery time (BDT). However, the potential impact of these improvements on the effectiveness of rescanning remains an underexplored area in the existing research. METHODS: We systematically investigated the impact of proton machine operating parameters on the effectiveness of layer rescanning in mitigating interplay effect during lung SBRT treatment, using the CIRS phantom. Focused on the Hitachi synchrotron particle therapy system, we explored machine operating parameters from our institution's current (2015) and upcoming systems (2025A and 2025B). Accumulated dynamic 4D dose were reconstructed to assess the interplay effect and layer rescanning effectiveness. RESULTS: Achieving target coverage and dose homogeneity within 2% deviation required 6, 6, and 20 times layer rescanning for the 2015, 2025A, and 2025B machine parameters, respectively. Beyond this point, further increasing the number of layer rescanning did not further improve the dose distribution. BDTs without rescanning were 50.4, 24.4, and 11.4 s for 2015, 2025A, and 2025B, respectively. However, after incorporating proper number of layer rescanning (six for 2015 and 2025A, 20 for 2025B), BDTs increased to 67.0, 39.6, and 42.3 s for 2015, 2025A, and 2025B machine parameters. Our data also demonstrated the potential problem of false negative and false positive if the randomness of the respiratory phase at which the beam is initiated is not considered in the evaluation of interplay effect. CONCLUSION: The effectiveness of layer rescanning for mitigating interplay effect is affected by machine operating parameters. Therefore, past clinical experiences may not be applicable to modern machines.


Assuntos
Neoplasias Pulmonares , Imagens de Fantasmas , Terapia com Prótons , Radiocirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Humanos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Terapia com Prótons/métodos , Radioterapia de Intensidade Modulada/métodos , Órgãos em Risco/efeitos da radiação
8.
J Appl Clin Med Phys ; 25(7): e14362, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38669175

RESUMO

PURPOSE: Proton stereotactic radiosurgery (PSRS) has emerged as an innovative proton therapy modality aimed at achieving precise dose delivery with minimal impact on healthy tissues. This study explores the dosimetric outcomes of PSRS in comparison to traditional intensity-modulated proton therapy (IMPT) by focusing on cases with small target volumes. A custom-made aperture system designed for proton therapy, specifically tailored to small target volumes, was developed and implemented for this investigation. METHODS: A prerequisite mechanical validation through an isocentricity test precedes dosimetric assessments, ensuring the seamless integration of mechanical and dosimetry analyses. Five patients were enrolled in the study, including two with choroid melanoma and three with arteriovenous malformations (AVM). Two treatment plans were meticulously executed for each patient, one utilizing a collimated aperture and the other without. Both plans were subjected to robust optimization, maintaining identical beam arrangements and consistent optimization parameters to account for setup errors of 2 mm and range uncertainties of 3.5%. Plan evaluation metrics encompassing the Heterogeneity Index (HI), Paddick Conformity Index (CIPaddick), Gradient Index (GI), and the R50% index to evaluate alterations in low-dose volume distribution. RESULTS: The comparative analysis between PSRS and traditional PBS treatment revealed no significant differences in plan outcomes, with both modalities demonstrating comparable target coverage. However, collimated apertures resulted in discernible improvements in dose conformity, dose fall-off, and reduced low-dose volume. CONCLUSIONS: This study underscores the advantageous impact of the aperture system on proton therapy, particularly in cases involving small target volumes.


Assuntos
Órgãos em Risco , Terapia com Prótons , Radiocirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Radiocirurgia/métodos , Terapia com Prótons/métodos , Radioterapia de Intensidade Modulada/métodos , Órgãos em Risco/efeitos da radiação , Melanoma/radioterapia , Melanoma/cirurgia
9.
Med Phys ; 51(7): 5119-5129, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38569159

RESUMO

BACKGROUND: Dosimetry in pre-clinical FLASH studies is essential for understanding the beam delivery conditions that trigger the FLASH effect. Resolving the spatial and temporal characteristics of proton pencil beam scanning (PBS) irradiations with ultra-high dose rates (UHDR) requires a detector with high spatial and temporal resolution. PURPOSE: To implement a novel camera-based system for time-resolved two-dimensional (2D) monitoring and apply it in vivo during pre-clinical proton PBS mouse irradiations. METHODS: Time-resolved 2D beam monitoring was performed with a scintillation imaging system consisting of a 1 mm thick transparent scintillating sheet, imaged by a CMOS camera. The sheet was placed in a water bath perpendicular to a horizontal PBS proton beam axis. The scintillation light was reflected through a system of mirrors and captured by the camera with 500 frames per second (fps) for UHDR and 4 fps for conventional dose rates. The raw images were background subtracted, geometrically transformed, flat field corrected, and spatially filtered. The system was used for 2D spot and field profile measurements and compared to radiochromic films. Furthermore, spot positions were measured for UHDR irradiations. The measured spot positions were compared to the planned positions and the relative instantaneous dose rate to equivalent fiber-coupled point scintillator measurements. For in vivo application, the scintillating sheet was placed 1 cm upstream the right hind leg of non-anaesthetized mice submerged in the water bath. The mouse leg and sheet were both placed in a 5 cm wide spread-out Bragg peak formed from the mono-energetic proton beam by a 2D range modulator. The mouse leg position within the field was identified for both conventional and FLASH irradiations. For the conventional irradiations, the mouse foot position was tracked throughout the beam delivery, which took place through repainting. For FLASH irradiations, the delivered spot positions and relative instantaneous dose rate were measured. RESULTS: The pixel size was 0.1 mm for all measurements. The spot and field profiles measured with the scintillating sheet agreed with radiochromic films within 0.4 mm. The standard deviation between measured and planned spot positions was 0.26 mm and 0.35 mm in the horizontal and vertical direction, respectively. The measured relative instantaneous dose rate showed a linear relation with the fiber-coupled scintillator measurements. For in vivo use, the leg position within the field varied between mice, and leg movement up to 3 mm was detected during the prolonged conventional irradiations. CONCLUSIONS: The scintillation imaging system allowed for monitoring of UHDR proton PBS delivery in vivo with 0.1 mm pixel size and 2 ms temporal resolution. The feasibility of instantaneous dose rate measurements was demonstrated, and the system was used for validation of the mouse leg position within the field.


Assuntos
Terapia com Prótons , Contagem de Cintilação , Animais , Camundongos , Contagem de Cintilação/instrumentação , Terapia com Prótons/instrumentação , Fatores de Tempo , Radiometria/instrumentação , Radiometria/métodos , Dosagem Radioterapêutica , Prótons
10.
Anal Chim Acta ; 1287: 342125, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38182395

RESUMO

BACKGROUND: MicroRNA-21 has been determined to be the only microRNA overexpressed in 11 types of solid tumors, making it an excellent candidate as a biomarker for disease diagnosis and therapy. Photoelectrochemical (PEC) biosensors have been widely used for quantification of microRNA-21. However, most PEC biosensing processes still suffer from some problems, such as the difficulty of avoiding the influence of interferents in complex matrices and the false-positive signals. There is a pressing need for establishing a sensitive and stable PEC method to detect microRNA-21. RESULTS: Herein, a nicking endonuclease-mediated rolling circle amplification (RCA)-assisted CRISPR/Cas12a PEC biosensor was fabricated for ultrasensitive detection of microRNA-21. The p-p type heterojunction PbS QDs/Co3O4 polyhedra were prepared as the quencher, thus the initial PEC signal attained the "off" state. Furthermore, the target was specifically identified and amplified by the RCA process. Then, its product single-stranded DNA S1 activated the cis- and trans-cleavage abilities of CRISPR/Cas12a, leading to almost all of the PbS QDs/Co3O4 polyhedra to leave the electrode surface, the p-n semiconductor quenching effect to be disrupted, and the signal achieving the "super-on" state. This pattern of PEC signal changed from "off" to "on" eliminated the interference of false-positive signals. The proposed PEC biosensor presented a satisfactory linear relationship ranging from 1 fM to 10 nM with a detection limit of 0.76 fM (3 Sb/N). SIGNIFICANCE AND NOVELTY: With innovatively synthesized PbS QDs/Co3O4 polyhedra as the effective quencher for PEC signal, the CRISPR/Cas12a dual-cleavage PEC biosensor possessed excellent selectivity, stability and repeatability. Furthermore, the detection of various miRNAs can be realized by changing the relevant base sequences in the constructed PEC biosensor. It also provides a powerful strategy for early clinical diagnosis and biomedical research.


Assuntos
Técnicas Biossensoriais , MicroRNAs , Cobalto , Sistemas CRISPR-Cas/genética , MicroRNAs/química , Fotoquímica , Técnicas Biossensoriais/métodos
11.
Int J Biol Macromol ; 259(Pt 2): 129319, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38211920

RESUMO

Blending poly(butylene succinate) (PBS) with another biodegradable polymer, polyglycolic acid (PGA), has been demonstrated to improve the barrier performance of PBS. However, blending these two polymers poses a challenge because of their incompatibility and large difference of their melting temperatures. In this study, we synthesized epoxidized soybean oil branched cardanol ether (ESOn-ECD), a bio-based and environmentally friendly compatibilizer, and used it to enhance the compatibility of PBS/PGA blends. It was demonstrated that the terminal carboxyl/hydroxyl groups of PBS and PGA can react with ESOn-ECD in situ, leading to branching and chain extension of PBS and PGA. The addition of ESO3-ECD to the blend considerably diminished the dispersed phase of PGA. Specifically, in comparison to the PBS/PGA blend without a compatibilizer, the diameter of the PGA phase decreased from 2.04 µm to 0.45 µm after the addition of 0.7 phr of ESO3-ECD, and the boundary between the two phases became difficult to distinguish. Additionally, the mechanical properties of the blends were improved after addition of ESO3-ECD. This research expands the potential applications of these materials and promotes the use of bio-based components in blend formulations.


Assuntos
Butileno Glicóis , Éteres , Fenóis , Poliésteres , Polímeros , Óleo de Soja , Ácido Poliglicólico
12.
J Appl Clin Med Phys ; 25(2): e14186, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37974385

RESUMO

PURPOSE: Noncoplanar plans (NCPs) are commonly used for proton treatment of bilateral head and neck (HN) malignancies. NCP requires additional verification setup imaging between beams to correct residual errors of robotic couch motion, which increases imaging dose and total treatment time. This study compared the quality and robustness of NCPs with those of coplanar plans (CPs). METHODS AND MATERIALS: Under an IRB-approved study, CPs were created retrospectively for 10 bilateral HN patients previously treated with NCPs maintaining identical beam geometry of the original plan but excluding couch rotations. Plan robustness to the inter-fractional variation (IV) of both plans was evaluated through the Dose Volume Histograms (DVH) of weekly quality assurance CT (QACT) sets (39 total). In addition, delivery efficiency for both plans was compared using total treatment time (TTT) and beam-on time (BOT). RESULTS: No significant differences in plan quality were observed in terms of clinical target volume (CTV) coverage (D95) or organ-at-risk (OAR) doses (p > 0.4 for all CTVs and OARs). No significant advantage of NCPs in the robustness to IV was found over CP, either. Changes in D95 of QA plans showed a linear correlation (slope = 1.006, R2  > 0.99) between NCP and CP for three CTV data points (CTV1, CTV2, and CTV3) in each QA plan (117 data points for 39 QA plans). NCPs showed significantly higher beam delivery time than CPs for TTT (539 ± 50 vs. 897 ± 142 s; p < 0.001); however, no significant differences were observed for BOT. CONCLUSION: NCPs are not more robust to IV than CPs when treating bilateral HN tumors with pencil-beam scanning proton beams. CPs showed plan quality and robustness similar to NCPs while reduced treatment time (∼6 min). This suggests that CPs may be a more efficient planning technique for bilateral HN cancer proton therapy.


Assuntos
Neoplasias de Cabeça e Pescoço , Terapia com Prótons , Radioterapia de Intensidade Modulada , Humanos , Prótons , Terapia com Prótons/métodos , Estudos Retrospectivos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Órgãos em Risco
13.
J Radiosurg SBRT ; 9(1): 75-82, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38029015

RESUMO

Our randomized clinical study comparing stereotactic body radiotherapy (SBRT) and stereotactic body proton therapy (SBPT) for early stage non-small cell lung cancer (NSCLC) was closed prematurely owing to poor enrollment, largely because of lack of volumetric imaging and difficulty in obtaining insurance coverage for the SBPT group. In this article, we describe technology improvements in our new proton therapy center, particularly in image guidance with cone beam CT (CBCT) and CT on rail (CTOR), as well as motion management with real-time gated proton therapy (RGPT) and optical surface imaging. In addition, we have a treatment planning system that provides better treatment plan optimization and more accurate dose calculation. We expect to re-start the SBPT program, including for early stage NSCLC as well as for other disease sites soon after starting patient treatment at our new proton therapy center.

14.
Phys Med Biol ; 68(21)2023 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-37844576

RESUMO

Objective:This study evaluates a compact Monte Carlo (MC) model of a pencil beam scanning clinical proton beam using TOPAS to estimate the dose out-of-field (OOF). Compact modelling means that the model starts from a pristine proton beam at the nozzle exit, customised based on acceptance and commissioning data, instead of modelling the full treatment head and room.Approach: First, in-field validation tests were performed. Then, the OOF dose was validated in an RW3 phantom with bubble detectors for personal neutron dosimetry (measuring the neutron dose equivalent) and thermoluminiescent detectors (measuring the absorbed dose by protons and gammas). Measurements were performed at 15 and 35 cm from the distal edge of the field for five different irradiation plans, covering different beam orientations, proton energies and a 40 mm range shifter. TOPAS simulations were performed with QGSP Binary Cascade HP (BIC) and QGSP Bertini HP (Bertini) hadron physics lists.Main results: In-field validation shows that MC simulations agree with point dose measurements within -2.5 % and +1.5 % at locations on- and off-axis and before, in and after the Bragg peak or plateau. The gamma passing rate 2%/3mm of four simulated treatment plans compared to the dose distribution calculated by the TPS exceeds 97 % agreement score. OOF dose simulations showed an average overestimation of 27 % of the neutron dose equivalent for the BIC hadron physics list and an average underestimation of 20 % for the Bertini hadron physics list. The simulated absorbed dose of protons and gammas showed a systematic underestimation which was on average 21 % and 51 % for BIC and Bertini respectively.Significance: Our study demonstrates that a compact MC model can reliably produce in-field data, while out-of-field dose data are within the uncertainties of the detector systems and MC simulations nuclear models, and do so with shorter modelling and faster calculation time.


Assuntos
Terapia com Prótons , Prótons , Dosagem Radioterapêutica , Radiometria , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador , Imagens de Fantasmas
15.
Cancers (Basel) ; 15(15)2023 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-37568697

RESUMO

PURPOSE: To investigate the feasibility of using cone-beam computed tomography (CBCT)-derived synthetic CTs to monitor the daily dose and trigger a plan review for adaptive proton therapy (APT) in head and neck cancer (HNC) patients. METHODS: For 84 HNC patients treated with proton pencil-beam scanning (PBS), same-day CBCT and verification CT (vfCT) pairs were retrospectively collected. The ground truth CT (gtCT) was created by deforming the vfCT to the same-day CBCT, and it was then used as a dosimetric baseline and for establishing plan review trigger recommendations. Two different synthetic CT algorithms were tested; the corrected CBCT (corrCBCT) was created using an iterative image correction method and the virtual CT (virtCT) was created by deforming the planning CT to the CBCT, followed by a low-density masking process. Clinical treatment plans were recalculated on the image sets for evaluation. RESULTS: Plan review trigger criteria for adaptive therapy were established after closely reviewing the cohort data. Compared to the vfCT, the corrCBCT and virtCT reliably produced dosimetric data more similar to the gtCT. The average discrepancy in D99 for high-risk clinical target volumes (CTV) was 1.1%, 0.7%, and 0.4% and for standard-risk CTVs was 1.8%, 0.5%, and 0.5% for the vfCT, corrCBCT, and virtCT, respectively. CONCLUSION: Streamlined APT has been achieved with the proposed plan review criteria and CBCT-based synthetic CT workflow.

16.
Phys Med Biol ; 68(17)2023 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-37506707

RESUMO

Objective.The treatment of mobile tumours using Pencil Beam Scanning (PBS) has become more prevalent in the last decade. However, to achieve the same beam delivery quality as for static tumours, treatments have to be combined with motion mitigation techniques, not limited but including, breath hold, gating and re-scanning, which typically prolong treatment time. In this article we present a novel method of bi-directional energy modulation and demonstrate our initial experience in improvement of treatment efficiency. Approach.At Paul Scherrer Institute Gantry 2 mobile tumours are treated by combining PBS with gating and volumetric re-scanning (VR), where the target volume is irradiated multiple times. Initial implementation of VR used only descending beam energies, creating a substantial dead time due to the beam-line initialization (ramping) before each re-scan. In 2019 we commissioned an energy meandering strategy that allows us to avoid beam line ramping in-between energy series while maintaining beam delivery quality.Main results.The measured beam parameters difference for both energy sequence are in the order of the typical daily variations: 0.2 mm in beam position and 0.2 mm in range. Using machine log files, we performed point-to-point dose difference calculations between original and new applications where we observed dose differences of less than 2%. After three years of operation employing bi-directional energy modulation, we have analysed the individual beam delivery time for 181 patients and have compared this to simulations of the timing behaviour assuming uni-directional energy sequence application. Depending on treatment complexity, we obtained plan delivery time reductions of up to 55%, with a median time gain of 17% for all types of treatments.Significance. Bi-directional energy modulation can help improving patient treatment efficiency by reducing delivery times especially for complex and specialised irradiations. It could be implemented in many existing facilities without significant additional hardware upgrades.


Assuntos
Neoplasias , Terapia com Prótons , Humanos , Terapia com Prótons/métodos , Neoplasias/radioterapia , Movimento (Física) , Suspensão da Respiração , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica
17.
Mar Pollut Bull ; 194(Pt B): 115295, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37517280

RESUMO

Nylon fishing nets have excellent strength and durability, but when lost at sea, their insufficient decomposition destroys habitats and spawning grounds, and pollutes the marine environment. This led to the development of poly(butylene succinate) (PBS) resin for biodegradable fishing gear based on aliphatic fibers. Prompted by the low stiffness and elastic recovery of PBS, we introduced two additional components into the molecular structure of PBS: adipic acid and ethylene glycol. These two new components were combined with succinic acid and 1,4-butanediol, the existing components of PBS, to synthesize poly(butylene adipate-co-butylene succinate-co-ethylene adipate-co-ethylene succinate) (PBEAS) resin via esterification and polycondensation reactions of a quaternary aliphatic copolyester. Although the molecular weight and molecular weight distribution of PBEAS are similar to those of PBS, it has excellent tensile strength, stiffness, elastic recovery, and biodegradability, with a low melting point for good production efficiency. These improvements are expected to allow PBEAS resin to be applied to gill nets for fish that require high stiffness, thereby expanding the use of biodegradable fishing gear.


Assuntos
Poliésteres , Ácido Succínico , Animais , Poliésteres/química , Caça , Succinatos/química , Adipatos/química , Etilenos
18.
Lasers Med Sci ; 38(1): 135, 2023 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-37300640

RESUMO

Pulsed laser ablation in liquids (PLAL) is considered as green, cost effective, and facile method to produce nanocolloids which exhibit anticancer effect. When comparing breast cancer with other types of cancers, breast cancer is considered as the second cause of death in women. The objective of this article is to test the cytotoxicity of carbon-based materials prepared by PLAL on both the normal (REF) cell line and the human breast cancer (MCF7) cell line. In this study, PLAL is used to prepare nanocolloids of asphalt and coal in different solvents (ethanol, dimethyl sulfoxide (DMSO), phosphate buffer saline (PBS), and distilled water (DW)). A fiber laser of wavelength of 1.06 µm and an average power of 10 watts was used to prepare different nanocolloids in different solvents from asphalt and coal. The cytotoxic effect of the prepared materials was tested against breast cancer MCF7 cell line in vitro. The asphalt in both ethanol and DMSO was found to have a significant cytotoxic effect and the growth inhibition (GI) was found to be 62.1% and 50.5% at concentrations of 620 and 80 ppm respectively, unlike the coal in DMSO which showed G.I. of 59.5%. Both the prepared materials in the mentioned solvents showed low cytotoxicity against the normal cell line (REF). We can conclude that the organic materials prepared in organic solvents using the PLAL had shown a low cytotoxicity against the (REF) cell line while they exhibited a significant cytotoxic effect against the MCF7 cell line. Further studies are recommended to test these prepared materials in vivo.


Assuntos
Neoplasias da Mama , Terapia a Laser , Feminino , Humanos , Solventes/farmacologia , Dimetil Sulfóxido/farmacologia , Carvão Mineral , Etanol/farmacologia , Células MCF-7
19.
Med Phys ; 50(11): 7263-7280, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37370239

RESUMO

BACKGROUND: The Dynamic Collimation System (DCS) has been shown to produce superior treatment plans to uncollimated pencil beam scanning (PBS) proton therapy using an in-house treatment planning system (TPS) designed for research. Clinical implementation of the DCS requires the development and benchmarking of a rigorous dose calculation algorithm that accounts for pencil beam trimming, performs monitor unit calculations to produce deliverable plans at all beam energies, and is ideally implemented with a commercially available TPS. PURPOSE: To present an analytical Pencil bEam TRimming Algorithm (PETRA) for the DCS, with and without its range shifter, implemented in the Astroid TPS (.decimal, Sanford, Florida, USA). MATERIALS: PETRA was derived by generalizing an existing pencil beam dose calculation model to account for the DCS-specific effects of lateral penumbra blurring due to the nickel trimmers in two different planes, integral depth dose variation due to the trimming process, and the presence and absence of the range shifter. Tuning parameters were introduced to enable agreement between PETRA and a measurement-validated Dynamic Collimation Monte Carlo (DCMC) model of the Miami Cancer Institute's IBA Proteus Plus system equipped with the DCS. Trimmer position, spot position, beam energy, and the presence or absence of a range shifter were all used as variables for the characterization of the model. The model was calibrated for pencil beam monitor unit calculations using procedures specified by International Atomic Energy Agency Technical Report Series 398 (IAEA TRS-398). RESULTS: The integral depth dose curves (IDDs) for energies between 70 MeV and 160 MeV among all simulated trimmer combinations, with and without the ranger shifter, agreed between PETRA and DCMC at the 1%/1 mm 1-D gamma criteria for 99.99% of points. For lateral dose profiles, the median 2-D gamma pass rate for all profiles at 1.5%/1.5 mm was 99.99% at the water phantom surface, plateau, and Bragg peak depths without the range shifter and at the surface and Bragg peak depths with the range shifter. The minimum 1.5%/1.5 mm gamma pass rates for the 2-D profiles at the water phantom surface without and with the range shifter were 98.02% and 97.91%, respectively, and, at the Bragg peak, the minimum pass rates were 97.80% and 97.5%, respectively. CONCLUSION: The PETRA model for DCS dose calculations was successfully defined and benchmarked for use in a commercially available TPS.


Assuntos
Terapia com Prótons , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador , Dosagem Radioterapêutica , Algoritmos , Imagens de Fantasmas , Método de Monte Carlo , Água
20.
Biochim Biophys Acta Bioenerg ; 1864(4): 148993, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37321385

RESUMO

Phycobilisomes (PBSs), which are huge pigment-protein complexes displaying distinctive color variations, bind to photosystem cores for excitation-energy transfer. It is known that isolation of supercomplexes consisting of PBSs and photosystem I (PSI) or PBSs and photosystem II is challenging due to weak interactions between PBSs and the photosystem cores. In this study, we succeeded in purifying PSI-monomer-PBS and PSI-dimer-PBS supercomplexes from the cyanobacterium Anabaena sp. PCC 7120 grown under iron-deficient conditions by anion-exchange chromatography, followed by trehalose density gradient centrifugation. The absorption spectra of the two types of supercomplexes showed apparent bands originating from PBSs, and their fluorescence-emission spectra exhibited characteristic peaks of PBSs. Two-dimensional blue-native (BN)/SDS-PAGE of the two samples showed a band of CpcL, which is a linker protein of PBS, in addition to PsaA/B. Since interactions of PBSs with PSI are easily dissociated during BN-PAGE using thylakoids from this cyanobacterium grown under iron-replete conditions, it is suggested that iron deficiency for Anabaena induces tight association of CpcL with PSI, resulting in the formation of PSI-monomer-PBS and PSI-dimer-PBS supercomplexes. Based on these findings, we discuss interactions of PBSs with PSI in Anabaena.


Assuntos
Anabaena , Cianobactérias , Complexo de Proteína do Fotossistema I/metabolismo , Tilacoides/metabolismo , Anabaena/metabolismo , Complexo de Proteína do Fotossistema II/metabolismo , Cianobactérias/metabolismo , Ficobilissomas/metabolismo , Ferro/metabolismo