Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29.403
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Arq. bras. oftalmol ; 88(1): e2023, 2025. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1568847

RESUMO

ABSTRACT Purpose: To determine the clinical outcomes in patients after type 1 Boston keratoprosthesis surgery and the significance of ultrasound biomicroscopy imaging for postoperative follow-up. Methods: This retrospective analysis included 20 eyes of 19 patients who underwent corneal transplantation with type 1 Boston keratoprosthesis between April 2014 and December 2021. Data on patient demographics, preoperative diagnosis, visual acuity, and postoperative clinical findings were analyzed. Results: Type 1 Boston keratoprosthesis implantation resulted in intermediate- and long-term positive outcomes. However, blindness and other serious complications such as glaucoma, retroprosthetic membrane formation, endophthalmitis, or retinal detachment also occurred. The use of ultrasound biomicroscopy imaging allowed for better evaluation of the back of the titanium plate, anterior segment structures, and the relationship of the prosthesis with surrounding tissues, which provided valuable postoperative information. Conclusion: Regular lifetime monitoring and treatment are necessary in patients who undergo Boston type 1 keratoprosthesis implantation for high-risk corneal transplantation. ultrasound biomicroscopy imaging can be a valuable imaging technique for the evaluation of patients with Boston type 1 keratoprosthesis, providing important information on anterior segment anatomy and potential complications. Further studies and consensus on postoperative follow-up protocols are required to optimize the management of patients with Boston type 1 keratoprosthesis.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38817688

RESUMO

Gossypiboma is an extremely rare adverse event occurring post-surgery, where surgical gauze is left within the body. If aseptically retained, it can lead to the formation of granulation tissue through chronic inflammation and adhesion with surrounding tissues, potentially persisting asymptomatically for many years. While diagnosis of this condition has been reported through various imaging modalities such as abdominal ultrasound and computed tomography, cases not presenting with typical findings are difficult for preoperative diagnosis, and instances where it is discovered postoperatively exist. Particularly when in contact with the gastrointestinal tract within the abdominal cavity, differentiation from submucosal tumors of the digestive tract becomes problematic. This report describes the imaging characteristics of endoscopic ultrasound and the usefulness of endoscopic ultrasound-fine-needle-aspiration for tissue diagnosis in the preoperative diagnosis of intra-abdominal gossypiboma.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38694539

RESUMO

Objective: This study aimed to investigate the usefulness of endoscopic ultrasound-guided tissue acquisition (EUS-TA) for diagnosing focal liver lesions in patients with a history of multiple primary malignant neoplasms. Methods: Among patients who underwent EUS-TA for focal liver lesions between 2016 and 2022, those with a history of multiple malignant neoplasms were included. A histologically confirmed malignant tumor within the past 5 years before EUS-TA was defined as a history of malignant neoplasm. The primary outcomes were diagnostic ability and adverse events of EUS-TA. Results: This study included 16 patients (median age, 73 [33-90] years), the median tumor size was 32 (6-51) mm, 14 had a history of double malignant neoplasms, whereas two had triple malignant neoplasms. Malignant neoplasms were detected histologically or cytologically in all cases. Immunohistochemistry was performed in 75% (12/16), and the final diagnosis of EUS-TA was metastatic liver tumor in 12 patients, and primary malignant liver tumor in four patients. The primary site could be identified in 11 of 12 metastatic tumor cases. The diagnostic yield of EUS-TA was 100% (16/16) for differentiating benign and malignant tumors and 94% (15/16) for confirming the histological type including the primary site of metastatic lesions. No adverse events were associated with the procedure. Conclusion: EUS-TA is a useful diagnostic modality for focal liver lesions in patients with a history of multiple malignant neoplasms, allowing for the differential diagnosis of primary and metastatic tumors and identification of the primary site of metastatic lesions.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38715895

RESUMO

Objectives: To identify and classify submucosal tumors by building and validating a radiomics model with gastrointestinal endoscopic ultrasonography (EUS) images. Methods: A total of 144 patients diagnosed with submucosal tumors through gastrointestinal EUS were collected between January 2019 and October 2020. There are 1952 radiomic features extracted from each patient's EUS images. The statistical test and the customized least absolute shrinkage and selection operator regression were used for feature selection. Subsequently, an extremely randomized trees algorithm was utilized to construct a robust radiomics classification model specifically tailored for gastrointestinal EUS images. The performance of the model was measured by evaluating the area under the receiver operating characteristic curve. Results: The radiomics model comprised 30 selected features that showed good discrimination performance in the validation cohorts. During validation, the area under the receiver operating characteristic curve was calculated as 0.9203 and the mean value after 10-fold cross-validation was 0.9260, indicating excellent stability and calibration. These results confirm the clinical utility of the model. Conclusions: Utilizing the dataset provided curated from gastrointestinal EUS examinations at our collaborating hospital, we have developed a well-performing radiomics model. It can be used for personalized and non-invasive prediction of the type of submucosal tumors, providing physicians with aid for early treatment and management of tumor progression.

5.
Theranostics ; 14(12): 4806-4821, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39239514

RESUMO

Sonogenetics is an emerging medical technology that uses acoustic waves to control cells through sonosensitive mediators (SSMs) that are genetically encoded, thus remotely and non-invasively modulating specific molecular events and/or biomolecular functions. Sonogenetics has opened new opportunities for targeted spatiotemporal manipulation in the field of gene and cell-based therapies due to its inherent advantages, such as its noninvasive nature, high level of safety, and deep tissue penetration. Sonogenetics holds impressive potential in a wide range of applications, from tumor immunotherapy and mitigation of Parkinsonian symptoms to the modulation of neural reward pathway, and restoration of vision. This review provides a detailed overview of the mechanisms and classifications of established sonogenetics systems and summarizes their applications in disease treatment and management. The review concludes by highlighting the challenges that hinder the further progress of sonogenetics, paving the way for future advances.


Assuntos
Medicina de Precisão , Humanos , Medicina de Precisão/métodos , Terapia Genética/métodos , Terapia Genética/tendências , Animais , Ondas Ultrassônicas , Neoplasias/terapia , Neoplasias/genética , Imunoterapia/métodos
6.
Cancer Med ; 13(17): e70146, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39248049

RESUMO

PURPOSE: This study aimed to identify ultrasound and clinicopathological characteristics related to recurrence in HER2-positive (HER2+) breast cancer, and to develop nomograms for predicting recurrence. METHODS: In this dual-center study, we retrospectively enrolled 570 patients with HER2+ breast cancer. The ultrasound and clinicopathological characteristics of hormone receptor (HR)-/HER2+ patients and HR+/HER2+ patients were analyzed separately according to HR status. Eighty percent of the original samples from HR-/HER2+ and HR+/HER2+ patients were extracted by bootstrap sampling as the training cohorts, while the remaining 20% were used as the external validation cohorts. Informative characteristics were screened through univariate and multivariable Cox regression in the training cohorts and used to develop nomograms for predicting recurrence. The predictive accuracy was calculated using Harrell's C-index and calibration curves. RESULTS: Three informative characteristics (axillary nodal status, calcification, and Adler degree) were identified in HR-/HER2+ patients, and another three (histological grade, axillary nodal status, and echogenic halo) in HR+/HER2+ patients. Based on these, two separate nomograms were constructed to assess recurrence risk. In the training cohorts, the C-index was 0.740 (95% CI: 0.667-0.811) for HR-/HER2+ nomogram, and 0.749 (95% CI: 0.679-0.820) for HR+/HER2+ nomogram. In the validation cohorts, the C-index was 0.708 (95% CI: 0.540-0.877) for HR-/HER2+ group, and 0.705 (95% CI: 0.557-0.853) for HR+/HER2+ group. The calibration curves also indicated the excellent accuracy of the nomograms. CONCLUSIONS: Ultrasound performance of HER2+ breast cancers with different HR status was significantly different. Nomograms integrating ultrasound and clinicopathological characteristics exhibited favorable performance and have the potential to serve as a reliable method for predicting recurrence in heterogeneous breast cancer.


Assuntos
Neoplasias da Mama , Recidiva Local de Neoplasia , Nomogramas , Receptor ErbB-2 , Humanos , Neoplasias da Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/metabolismo , Feminino , Receptor ErbB-2/metabolismo , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/patologia , Estudos Retrospectivos , Adulto , Idoso , Receptores de Estrogênio/metabolismo , Receptores de Progesterona/metabolismo , Biomarcadores Tumorais/metabolismo , Ultrassonografia Mamária/métodos
7.
ACS Appl Bio Mater ; 2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-39231419

RESUMO

The synthesis of bioinspired metal-organic frameworks (MOFs) performed in mild conditions with a high quality is greatly demanded. Moreover, the influence of the morphology and structure of bio-MOFs on the cell interaction and toxicity is important to determine. In this work, we developed an ultrasound (US)-assisted synthesis of HKUST-1 MOFs under mild conditions and investigated the influence of the parameters of synthesis on the morphology, structure, and biological properties of the developed MOFs. It was found that the US power, reaction time, temperature, and type of solvent composition would affect the morphology, size, and yield of the obtained crystals. Employing the optimal synthetic conditions, five types of HKUST-1 MOFs were prepared, achieving highest yields (67.8-96.2%) and different morphologies (octahedral, dodecahedral, icosahedral). The relationship between the morphological features and biological properties of developed bio-MOFs was evaluated and discussed. The cellular association and cytotoxicity of MOF@US and MOF@US-PARG were studied on various cell cultures, i.e. normal mouse embryonic fibroblasts (MEF NF2), chronic myeloid leukemia (K562), and mouse melanoma (B16-F10). The experimental results showed that MOF@US-PARG has a higher percentage of association compared to MOF@US. It has also been shown that the cytotoxicity depends on the concentration and surface modification of the developed MOFs.

8.
Cureus ; 16(7): e65823, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39228896

RESUMO

Carpal tunnel syndrome (CTS) is the most prevalent focal mononeuropathy worldwide and is traditionally diagnosed based on clinical history, examination, and nerve conduction studies. Surgical release is the gold standard in cases where conservative management fails; however, it is prudent to obtain imaging before planning such intervention. We present the case of a 47-year-old woman who presented with typical symptoms of CTS, which was confirmed with nerve conduction studies and was being considered for carpal tunnel release surgery. Her history and laboratory studies revealed rheumatoid arthritis and subsequent ultrasonography showed swelling of the median nerve just proximal to the transverse carpal ligament at the level of pronator quadratus muscle. The possibility of a nerve sheath tumour or tenosynovitis with edematous fascicles of the median nerve was considered, and a decision was taken to give a short course of prednisolone 1 mg/kg, to which she clinically responded and the repeat ultrasonography showed near complete resolution of the focal nerve enlargement. This case emphasizes the role of point-of-care neuromuscular ultrasound (NMUS) in identifying the underlying cause of CTS and validates NMUS as a powerful tool in reaching a comprehensive diagnosis in entrapment neuropathies and it should be incorporated into the routine protocol of diagnosis of these disorders.

9.
Endocr Pract ; 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39236787

RESUMO

The rapid evolution of ultrasound (US) technology has dramatically changed the medical field. Ideally suited for evaluation of anatomic disorders of the thyroid, coupled with its ease of use at the bedside, US has become an essential tool for Endocrinologists over the last 50 years. This noninvasive technology provides a sensitive and specific instrument for malignancy risk prediction of thyroid nodules, surveillance for recurrent thyroid cancer, and diagnosis of autoimmune thyroid disorders. While US has proven invaluable for such diagnostic purposes, its extensive use also has resulted in important negative consequences. This review will discuss the evolution of US equipment for the evaluation of thyroid disorders, its use in interventional procedures, and the unintended outcomes from the widespread adoption of this technology. Finally, this article will explore the potential future applications for US technology and its related advancements.

10.
Clin Podiatr Med Surg ; 41(4): 797-821, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39237185

RESUMO

Ultrasound is a high-resolution, real-time imaging modality that is frequently used for image-guided procedures. Due to the highly complex anatomy of the foot and ankle, ultrasound should be considered a first-line imaging modality for injections and procedures in this region.


Assuntos
, Ultrassonografia de Intervenção , Humanos , Pé/diagnóstico por imagem , Tornozelo/diagnóstico por imagem , Injeções Intra-Articulares/métodos , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia
11.
Clin Podiatr Med Surg ; 41(4): 823-836, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39237186

RESUMO

In the past few years, advances in clinical imaging in the realm of foot and ankle have been consequential and game changing. Improvements in the hardware aspects, together with the development of computer-assisted interpretation and intervention tools, have led to a noticeable improvement in the quality of health care for foot and ankle patients. Focusing on the mainstay imaging tools, including radiographs, computed tomography scans, and ultrasound, in this review study, the authors explored the literature for reports on the new achievements in improving the quality, accuracy, accessibility, and affordability of clinical imaging in foot and ankle.


Assuntos
Inteligência Artificial , , Humanos , Pé/diagnóstico por imagem , Tomografia Computadorizada por Raios X/normas , Tornozelo/diagnóstico por imagem , Automação , Ultrassonografia , Diagnóstico por Imagem/normas
12.
Clin Podiatr Med Surg ; 41(4): 853-864, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39237188

RESUMO

High-resolution ultrasound (US) can be used to assess soft tissue abnormalities in the foot and ankle. Compared to MRI, it has lower cost, is widely available, allows portability and dynamic assessment. US is an excellent method to evaluate foot and ankle tendon injuries, ligament tears, plantar fascia, peripheral nerves, and the different causes of metatarsalgia.


Assuntos
Ultrassonografia , Humanos , Ultrassonografia/métodos , Pé/diagnóstico por imagem , Traumatismos do Tornozelo/diagnóstico por imagem , Traumatismos do Pé/diagnóstico por imagem , Traumatismos dos Tendões/diagnóstico por imagem , Tornozelo/diagnóstico por imagem
13.
Ultrasound Med Biol ; 2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-39237425

RESUMO

OBJECTIVE: To assess the ability of the pressure gradient between breast lesions and adjacent normal tissue estimated by 3D subharmonic-aided pressure estimation (SHAPE) to characterize indeterminate breast lesions. METHODS: This prospective study enrolled patients scheduled for ultrasound-guided needle biopsies of a breast lesion. Before the biopsy, 3D SHAPE data were collected from the breast lesion during the infusion of an ultrasound contrast agent (Definity) as well as after clearance of the agent. Direct, invasive pressure measurements in the lesion and adjacent normal tissue were then obtained using an intracompartmental pressure monitoring system (C2DX) before tissue sampling as part of the biopsy procedure. The mean SHAPE gradient and invasive measurement gradient between the lesion and adjacent normal tissue were compared to the biopsy results. The SHAPE gradients were also compared to the invasive pressure gradients. RESULTS: There were 8 malignant and 13 benign lesions studied. The SHAPE gradients and invasive pressure gradients were significantly different between the benign and malignant lesions (2.86 ± 3.24 vs. -0.03 ± 1.72 a.u.; p = 0.03 and 9.9 ± 8.5 vs. 20.9 ± 8.0 mmHg; p = 0.008, respectively). The area under the curves, specificities, and sensitivities for detecting malignancy by SHAPE gradients and invasive pressure gradients were 0.79 and 0.88, 77% and 92%, and 88% and 50%, respectively. A weak negative correlation was found between the SHAPE and invasive pressure gradients (r = -0.2). CONCLUSION: The pressure gradient between a breast lesion and adjacent normal tissue estimated by 3D SHAPE shows potential for characterizing indeterminate breast lesions.

14.
Int Urol Nephrol ; 2024 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-39237701

RESUMO

This retrospective analysis investigates the outcomes and complications of 682 kidney biopsies performed at ARNAS G. Brotzu from 2010 to 2021. Our findings indicate a minor complication rate of 9.1%, with severe complications being exceedingly rare at 0.3%. Age did not contribute to an increased risk, underscoring the procedure's safety across age groups. Clinical hypnosis was incorporated into the biopsy protocol in a subset of patients (n = 45) from April 2019 to December 2023. Over 90% of these patients reported no perception of the procedure, and 60% experienced no pain. According to STAY-Y test scores, this approach significantly reduced anxiety post-procedure (p = 0.001); no major or minor complications were observed in this group. While our study reaffirms the very low risk of severe complications in kidney biopsies, it also highlights the potential benefits of adjunct clinical hypnosis in enhancing patient comfort and cooperation during the procedure. This exploration opens a promising avenue for further investigation to improve patient experiences and procedural outcomes in kidney biopsies.

15.
Int J Hyperthermia ; 41(1): 2401417, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39255969

RESUMO

OBJECTIVE: In this study, we established a Sprague-Dawley rat model of vulvar squamous intraepithelial lesions and investigated the impact of focused ultrasound on the expression of hypoxia-inducible factor-1α (HIF-1α), vascular endothelial growth factor (VEGF) and mutant type p53 (mtp53) in the vulvar skin of rats with low-grade squamous intraepithelial lesions (LSIL). MATERIALS AND METHODS: The vulvar skin of 60 rats was treated with dimethylbenzanthracene (DMBA) and mechanical irritation three times a week for 14 weeks. Rats with LSIL were randomly allocated into the experimental group or the control group. The experimental group was treated with focused ultrasound, while the control group received sham treatment. RESULTS: After 14 weeks treatment of DMBA combined with mechanical irritation, LSIL were observed in 44 (73.33%) rats, and high-grade squamous intraepithelial lesions (HSIL) were observed in 14 (23.33%) rats. 90.91% (20/22) of rats showed normal pathology and 9.09% (2/22) of rats exhibited LSIL in the experimental group at four weeks after focused ultrasound treatment. 22.73% (5/22) of rats exhibited LSIL, 77.27% (17/22) of rats progressed to HSIL in the control group. Compared with the control-group rats, the levels of HIF-1α, VEGF and mtp53 were significantly decreased in experimental-group rats (p < 0.05). CONCLUSIONS: These results indicate that DMBA combined with mechanical irritation can induce vulvar squamous intraepithelial lesion in SD rats. Focused ultrasound can treat LSIL safely and effectively, prevent the progression of vulvar lesions, and improve the microenvironment of vulvar tissues by decreasing the localized expression of HIF-1α, VEGF, and mtp53 in rats.


Assuntos
Ratos Sprague-Dawley , Lesões Intraepiteliais Escamosas , Animais , Feminino , Ratos , Lesões Intraepiteliais Escamosas/patologia , Subunidade alfa do Fator 1 Induzível por Hipóxia/metabolismo , Fator A de Crescimento do Endotélio Vascular/metabolismo , Neoplasias Vulvares/patologia , Neoplasias Vulvares/terapia , Terapia por Ultrassom/métodos , Proteína Supressora de Tumor p53/metabolismo
16.
Eur J Breast Health ; 20(3): 194-198, 2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-39257011

RESUMO

OBJECTIVE: Breast abscesses are localized purulent collections, often arising from bacterial mastitis, and pose significant health risks, especially for lactating women. The aim of this study was to compare the efficacy and outcomes of two different treatment approaches: Traditional incision and drainage (I&D) versus ultrasound (USG)-guided aspiration in breast abscess management. MATERIALS AND METHODS: Fifty female patients with breast abscesses were enrolled and divided into two groups: Group A (n = 25, I&D) and group B (n = 25, USG-guided aspiration). Group A underwent I&D under general anaesthesia and group B underwent USG-guided aspiration under local anaesthesia. The patients were followed up for two weeks after the procedure. Patient demographics, abscess characteristics, treatment outcomes, and complications were analyzed. RESULTS: The mean age of patients was 36.4 and 31.8 in group A and B, respectively and the mean abscess size was 5.7 cm. The study found that USG-guided aspiration was associated with several advantages over I&D. Patients in group B experienced shorter healing times (5 days vs. 13 days, p = 0.001), lower rates of residual abscesses (12% vs. 36%, p = 0.047), and no recurrence after two weeks vs. 28% in group A (p = 0.012). Notably, the resumption of lactation was significantly greater in group B (91.67% vs. 20%). Importantly, patients in group B had no scarring, while 37% in group A healed with scars. CONCLUSION: These results highlight that USG-guided aspiration offers a minimally invasive and effective method for managing breast abscesses, leading to quicker recovery, better cosmetic outcomes, and higher patient satisfaction compared to the traditional I&D approach. Early diagnosis and intervention with USG-guided aspiration can prevent complications and reduce the need for open surgery. Based on these findings, USG-guided aspiration is a safer and more efficient method for treating breast abscesses, particularly when initiated promptly after diagnosis.

17.
Eur J Breast Health ; 20(3): 228-230, 2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-39257016

RESUMO

Systemic lupus erythematosus (SLE) and sarcoidosis are two of the most well-recognized, chronically diagnosed conditions in the United States, with a plethora of known multisystem manifestations. With regard to breast pathology, lupus mastitis is a relatively uncommon manifestation of SLE, commonly involving both the mammary gland and subcutaneous soft tissues of the breast. Sarcoidosis in the breast is a similarly, exceedingly rare manifestation of this multi-system disorder, classically presenting with non-caseating granulomas. Both present with non-specific mammographic and sonographic features. We present a 62-year-old female with known diagnosis of discoid lupus and Graves' disease who presented initially with an abnormal screening mammogram, ultimately undergoing mammographic work-up and subsequent biopsy demonstrating lupus mastitis, including vasculitis, panniculitis, and fibrosis with chronic inflammation. The patient was also found to have small non-caseating granulomas, some in a perivascular distribution, classically seen in sarcoidosis. Given the rarity of both manifestations, our case explores the coexistence of these autoimmune processes and this atypical presentation.

18.
Ultrason Imaging ; : 1617346241276168, 2024 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-39257175

RESUMO

We investigate the predictive value of a comprehensive model based on preoperative ultrasound radiomics, deep learning, and clinical features for pathological complete response (pCR) after neoadjuvant chemotherapy (NAC) for the breast cancer. We enrolled 155 patients with pathologically confirmed breast cancer who underwent NAC. The patients were randomly divided into the training set and the validation set in the ratio of 7:3. The deep learning and radiomics features of pre-treatment ultrasound images were extracted, and the random forest recursive elimination algorithm and the least absolute shrinkage and selection operator were used for feature screening and DL-Score and Rad-Score construction. According to multifactorial logistic regression, independent clinical predictors, DL-Score, and Rad-Score were selected to construct the comprehensive prediction model DLRC. The performance of the model was evaluated in terms of its predictive effect, and clinical practicability. Compared to the clinical, radiomics (Rad-Score), and deep learning (DL-Score) models, the DLRC accurately predicted the pCR status, with an area under the curve (AUC) of 0.937 (95%CI: 0.895-0.970) in the training set and 0.914 (95%CI: 0.838-0.973) in the validation set. Moreover, decision curve analysis confirmed that the DLRC had the highest clinical value among all models. The comprehensive model DLRC based on ultrasound radiomics, deep learning, and clinical features can effectively and accurately predict the pCR status of breast cancer after NAC, which is conducive to assisting clinical personalized diagnosis and treatment plan.

19.
Ultrason Sonochem ; 110: 107052, 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39241461

RESUMO

Tubocapsicum anomalum, a Chinese medicinal plant rich in anti-tumor withanolides, requires efficient extraction methods. In this paper, an HPLC method was first established for the detection of withanolides, and gradient elution was carried out using a methanol-water solvent system. It was found that the content of withanolides was the highest in the leaves of T. anomalum, followed by the stems and fruits, and almost none in the roots. During the actual picking process, the quantity of leaves collected was relatively small, while the number of stems was the highest. Therefore, the Box-Behnken response surface method was used to optimize the ultrasonic-assisted extraction process of withanolides from the stems of T. anomalum. The optimal extraction conditions were determined as follows: the liquid-solid ratio was 20:1, the extraction solvent was 70 % ethanol, the ultrasonic power was 250 W, the ultrasonic time was 40 min, and the ultrasonic temperature was 50 °C. Under these conditions, the average yields of tubocapsenolide A (Te-A) and tubocapsanolide A (Ta-A) can reach 2.87 ± 0.12 mg/g and 1.18 ± 0.05 mg/g, respectively. We further compared extraction rates of two withanolides from different parts of T. anomalum using ultrasonic and traditional extraction methods. Ultrasonic extraction significantly increased rates, with the highest yields from leaves, followed by stems and fruits. The results show that ultrasonic optimization can improve extraction rate, reduce time, lower costs, enhance quality, and increase yield. Therefore, the optimized ultrasonic-assisted extraction process was adopted to extract the aerial parts of T. anomalum and separate the components. After optimization, the extract underwent several chromatographic separations to isolate eight previously undescribed withanolides (1-8) and two artificial withanolides (9-10), in addition to fifteen known compounds (11-25). Their structures were established through extensive spectroscopic data analysis. The compounds were evaluated for their antiproliferative effects against multiple cancer cell lines, including human hepatocellular carcinoma cells (HepG2, Hep3B, and MHCC97-H), human lung cancer cells (A549), human fibro-sarcoma cancer cells (HT1080), human chronic myeloid leukemia cells (K562), and human breast cancer cells (MDA-MB-231 and MCF7). Compounds 1-3, 5, 7, 11, 13, 15-16, and 22 displayed significant activity with IC50 values of 5.14-19.87 µM. The above results indicate that ultrasonic-assisted extraction technology can be used to obtain new withanolides more efficiently from T. anomalum, thereby enhancing the utilization rate of T. anomalum resources.

20.
Int J Food Microbiol ; 426: 110898, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39241544

RESUMO

This study investigated the antibacterial effect of ultrasound (US) combined with Litsea cubeba essential oil nanoemulsion (LEON) on Salmonella Typhimurium in kiwifruit juice and effect on the quality and sensory properties of kiwifruit juice. In this study, LEON prepared by ultrasonic emulsification method had a good particle size distribution and high stability. The US+LEON treatment significantly (P < 0.05) improved antibacterial efficacy, compared to the control, and would not destroy the nutritional components containing ascorbic acid, flavonoids, total phenol and total soluble solids. Meanwhile, US+LEON treatment enhanced 2, 2-diphenyl-1-picrylhydrazyl (DPPH), 2, 2'-azino-bis-(3-ethylbenzothiazoline-6 sulfonic acid) (ABTS) radical scavenging capacity and ferric ion reducing antioxidant power (FRAP). In terms of sensory properties, US and LEON had a significant (P < 0.05) effect on the odor and overall morphology of kiwifruit juice. The enhance of antibacterial efficacy and the retention of nutrients by combined treatments shows that US+LEON is a promising antibacterial method that will provide new ideas for the processing and safety of fruit juices, and the US parameters and LEON concentration should be adjusted to reduce the effect on food sensory properties in future studies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA