1.
ACS Appl Mater Interfaces ; 16(15): 19421-19431, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38568871

RESUMO

The employment of flexible piezoresistive sensors has sparked growing interest within the realm of wearable electronic devices, specifically in the fields of health detection and e-skin. Nevertheless, the advancement of piezoresistive sensors has been impeded by their limited sensitivity and restricted operating ranges. Consequently, it is imperative to fabricate sensors with heightened sensitivity and expanded operating ranges through the utilization of the appropriate methodologies. In this paper, piezoresistive sensors were fabricated utilizing electrospun polyvinylidene fluoride/polyacrylonitrile/polyethylene-polypropylene glycol multilayer fibrous membranes anchored with polypyrrole granules as the sensing layer, while electrospun thermoplastic polyurethane (TPU) fibers were employed as the flexible substrate. The sensitivity of the sensor is investigated by varying the fiber diameter of the sensing layer. The experimental findings reveal that a concentration of 14 wt % in the spinning solution exhibits high sensitivity (996.7 kPa-1) within a wide working range (0-10 kPa). This is attributed to the favorable diameter of the fibers prepared at this concentration, which facilitates the uniform in situ growth of pyrrole. The highly deformable TPU flexible fibers and multilayer sensing layer structure enable different linear responses across a broad pressure range (0-1 MPa). Furthermore, the sensor demonstrates good cyclic stability and can detect human movements under different pressures. These results suggest that the piezoresistive sensor with a wide operating range and high sensitivity has significant potential for future health monitoring and artificial intelligence applications.

2.
IEEE J Transl Eng Health Med ; 9: 2700306, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33329944

RESUMO

Objective: To investigate the feasibility of using a wireless wearable device (WD) in differentiated thyroid cancer (DTC) patients undergoing radionuclide therapy with I-131 (RAI) and protected hospitalization, this study compared the measurements of residual radioactivity obtained with those registered by a permanent environmental home device (HD). Methods: Twenty consecutive patients undergoing RAI hospitalized in restricted, controlled areas were enrolled. The patients underwent comprehensive monitoring of vital/nonvital parameters. We obtained 45580± 13 measurements from the WD, detecting the residual radioactivity for each patient during approximately 56 hours of hospitalization, collecting data 53 times per hour. The samples, collected during daily activities, were averaged every two hours, and the results correlated with those from the HD. Bland-Altman analysis was also used to evaluate the agreement between the two techniques. Results: A significant relationship between the WD and HD was observed (r = 0.96, p < 0.0001). Bland-Altman analysis recognized the agreement between measurements by the WD and HD. The mean value at the end of the first day of hospitalization was 80.81 microSv/h and 60.77 microSv/h (p = ns for WD and HD), whereas those at the end of the second day were 47.08 and 24.96 (p = ns). In the generalized linear model (GLM), a similar trend in performance across time was found with the two techniques. Conclusion: This study demonstrates good agreement between the residual radioactivity measures estimated by the WD and HD modalities, rendering them interchangeable. This approach will allow both the optimization of medical staff exposure and safer patient discharge. Abbreviations: wireless device (WD); differentiated thyroid cancer (DTC); radionuclide therapy with I-131 (RAI); home device (HD); generalized linear model (GLM).


Assuntos
Radioatividade , Neoplasias da Glândula Tireoide , Dispositivos Eletrônicos Vestíveis , Estudos de Viabilidade , Humanos , Radioisótopos do Iodo/uso terapêutico , Neoplasias da Glândula Tireoide/radioterapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA