Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 139
Filtrar
1.
J Cardiovasc Magn Reson ; 26(2): 101085, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-39154806

RESUMO

BACKGROUND: Quantitative stress cardiac magnetic resonance (CMR) can be performed using the dual-sequence (DS) technique or dual-bolus (DB) method. It is unknown if DS and DB produce similar results for myocardial blood flow (MBF) and myocardial perfusion reserve (MPR). The study objective is to investigate if there are any differences between DB- and DS-derived MBF and MPR. METHODS: Retrospective observational study with 168 patients who underwent stress CMR. DB and DS methods were simultaneously performed on each patient on the same day. Global and segmental stress MBF and rest MBF values were collected. RESULTS: Using Bland-Altman analysis, segmental and global stress MBF values were higher in DB than DS (0.22 ± 0.60 mL/g/min, p < 0.001 and 0.20 ± 0.48 mL/g/min, p = 0.005, respectively) with strong correlation (r = 0.81, p < 0.001 for segmental and r = 0.82, p < 0.001 for global). In rest MBF, segmental and global DB values were higher than by DS (0.15 ± 0.51 mL/g/min, p < 0.001 and 0.14 ± 0.36 mL/g/min, p = 0.011, respectively) with strong correlation (r = 0.81, p < 0.001 and r = 0.77, p < 0.001). Mean difference between MPR by DB and DS was -0.02 ± 0.68 mL/g/min (p = 0.758) for segmental values and -0.01 ± 0.49 mL/g/min (p = 0.773) for global values. MPR values correlated strongly as well in both segmental and global, both (r = 0.74, p < 0.001) and (r = 0.75, p < 0.001), respectively. CONCLUSION: There is a very good correlation between DB- and DS-derived MBF and MPR values. However, there are significant differences between DB- and DS-derived global stress and rest MBF. While MPR values did not show statistically significant differences between DB and DS methods.

2.
Eur Heart J Imaging Methods Pract ; 2(1): qyae010, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-39045203

RESUMO

Aims: Endothelial dysfunction is a systemic disorder and risk factor for atherosclerosis. Our aim was to assess whether there is a relation between peripheral endothelial function and myocardial perfusion in patients with coronary artery disease (CAD). Methods and results: We prospectively studied 54 patients, who had a positive result for obstructive CAD in coronary CT angiography. Myocardial perfusion (15O)H2O positron emission tomography was imaged at rest and during adenosine-induced maximal vasodilation. Peripheral endothelial function was assessed by measuring flow-mediated dilation (FMD) with ultrasound from the left brachial artery. There was a statistically significant correlation between FMD and global hyperaemic myocardial blood flow (MBF; r = 0.308, P = 0.023). The correlation remained statistically significant when controlling for gender, height, and diastolic blood pressure at rest (r = 0.367, P = 0.008). Receiver operating character analysis, however, yielded an area under curve of only 0.559 (P = 0.492) when FMD was used to predict reduced MBF (below 2.3 mL/g/min). Patients with significantly decreased MBF (n = 14) underwent invasive coronary angiography. FMD showed an inverse correlation with the severity of the most significant stenosis (r = -0.687, P = 0.007). Conclusion: Peripheral endothelial function is related with hyperaemic MBF and with the severity of CAD in invasive coronary angiography. Due to insufficient sensitivity and specificity in the identification of reduced MBF, FMD is not suitable for clinical practice at the individual level. However, it works at the population level as a research tool when assessing endothelial dysfunction in patients with CAD.

3.
Front Cardiovasc Med ; 11: 1371810, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38873265

RESUMO

Background: Cardiac systolic dysfunction is a poor prognostic marker in light-chain (AL) cardiomyopathy, a primary interstitial disorder; however, its pathogenesis is poorly understood. Purpose: This study aims to analyze the effects of extracellular volume (ECV) expansion, a surrogate marker of amyloid burden on myocardial blood flow (MBF), myocardial work efficiency (MWE), and left ventricular (LV) systolic dysfunction in AL amyloidosis. Methods: Subjects with biopsy-proven AL amyloidosis were prospectively enrolled (April 2016-June 2021; Clinicaltrials.gov ID NCT02641145) and underwent cardiac magnetic resonance imaging (MRI) to quantify rest MBF by perfusion imaging, LV ejection fraction (LVEF) by cine MRI, and ECV by pre- and post-contrast T1 mapping. The MWE was estimated as external cardiac work from the stroke volume and mean arterial pressure normalized to the LV myocardial mass. Results: Rest MBF in 92 subjects (62 ± 8 years, 52 men) with AL amyloidosis averaged 0.87 ± 0.21 ml/min/g and correlated with MWE (r = 0.42; p < 0.001). Rest MBF was similarly low in subjects with sustained hematologic remission after successful AL amyloidosis therapy (n = 21), as in those with recently diagnosed AL amyloidosis. Both MBF and MWE decreased by ECV tertile (p < 0.01 for linear trends). The association of ECV with MWE comprised a direct effect (84% of the total effect; p < 0.001) on MWE from adverse interstitial remodeling assessed by ECV and an indirect effect (16% of the total effect; p < 0.001) mediated by MBF. There was a significant base-to-apex gradient of rest MBF in subjects with higher amyloid burden. Conclusions: In AL amyloidosis, both MBF and MWE decrease as cardiac amyloid burden and ECV expansion increase. Both structural and vascular changes from ECV expansion and myocardial amyloid burden appear to contribute to lower MWE.

4.
Acta Radiol ; 65(7): 724-734, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38630492

RESUMO

BACKGROUND: Dynamic myocardial computed tomography perfusion (CTP) is a novel imaging technique that increases the applicability of CT for cardiac imaging; however, the scanning requires a substantial radiation dose. PURPOSE: To investigate the feasibility of dose reduction in dynamic CTP by comparing all-heartbeat acquisitions to periodic skipping of heartbeats. MATERIAL AND METHODS: We retrieved imaging data of 38 dynamic CTP patients and created new datasets with every fourth, third or second beat (Skip1:4, Skip1:3, Skip1:2, respectively) removed. Seven observers evaluated the resulting images and perfusion maps for perfusion deficits. The mean blood flow (MBF) in each of the 16 myocardial segments was compared per skipped-beat level, normalized by the respective MBF for the full dose, and averaged across patients. The number of segments/cases whose MBF was <1.0 mL/g/min were counted. RESULTS: Out of 608 segments in 38 cases, the total additional number of false-negative (FN) segments over those present in the full-dose acquisitions and the number of additional false-positive cases were shown as acquisition (segment [%], case): Skip1:4: 7 (1.2%, 1); Skip1:3: 12 (2%, 3), and Skip1:2: 5 (0.8%, 2). The variability in quantitative MBF analysis in the repeated analysis for the reference condition resulted in 8 (1.3%) additional FN segments. The normalized results show a comparable MBF across all segments and patients, with relative mean MBFs as 1.02 ± 0.16, 1.03 ± 0.25, and 1.06 ± 0.30 for the Skip1:4, Skip1:3, and Skip1:2 protocols, respectively. CONCLUSION: Skipping every second beat acquisition during dynamic myocardial CTP appears feasible and may result in a radiation dose reduction of 50%. Diagnostic performance does not decrease after removing 50% of time points in dynamic sequence.


Assuntos
Imagem de Perfusão do Miocárdio , Doses de Radiação , Humanos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/métodos , Idoso , Estudos de Viabilidade , Tomografia Computadorizada por Raios X/métodos , Adulto , Frequência Cardíaca/fisiologia , Idoso de 80 Anos ou mais
5.
J Clin Med ; 13(5)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38592092

RESUMO

(1) Background: The objective of this study was to determine the optimal post-processing model for dynamic cadmium-zinc-telluride single-photon emission computed tomography (CZT-SPECT). (2) Methods: A total of 235 patients who underwent diagnostic invasive coronary angiography within three months of the SPECT and those who had coronary computed tomography angiography (CCTA) before SPECT (within 3 months) were enrolled in this study. Each SPECT study was processed to obtain global and regional stress myocardial blood flow (sMBF), rest-MBF (rMBF), myocardial flow reserve (MFR) and flow difference (FD) estimates obtained with 1-tissue-compartment (1TCM) and net retention (NR) modes, both with and without attenuation correction. (3) Results: The use of AC led to significantly higher sMBF, rMBF and DF values obtained by 1TCM compared those values derived by 1TCM with NAC; the lowest values of stress MBF and rest MBF were obtained by 1TCM_NAC. The resting flow, MFR and DF were significantly (p < 0.005) higher in the AC model than in NAC. All quantitative variables were significantly (p < 0.05) higher in NR_NAC than in the 1TC_NAC model. Finally, sMBF, rMBF and FD showed significantly (p < 0.05) higher values by using 1TMC_AC compared to NR_AC. (4) Conclusions: We suggested that 1-compartment and net retention models correctly reflect coronary microcirculation and can be used for clinical practice for evaluating quantitative myocardial perfusion by dynamic SPECT. Attenuation correction is an important step in post-processing dynamic SPECT data, which increases the consistency and diagnostic accuracy of models.

6.
J Psychosom Res ; 181: 111672, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38636300

RESUMO

OBJECTIVE: Physicians face documented challenges to their mental and physical well-being, particularly in the forms of occupational burnout and cardiovascular disease. This study examined the previously under-researched intersection of early life stressors, prolonged occupational stress, and cardiovascular health in physicians. METHODS: Participants were 60 practicing male physicians, 30 with clinical burnout, defined by the Maslach Burnout Inventory, and 30 non-burnout controls. They completed the Adverse Childhood Experiences (ACE) Questionnaire asking about abuse, neglect and household dysfunctions before the age of 18, and the Perceived Stress Scale to rate thoughts and feelings about stress in the past month. Endothelium-independent (adenosine challenge) coronary flow reserve (CFR) and endothelium-dependent CFR (cold pressor test) were assessed by positron emission tomography-computed tomography. The segment stenosis score was determined by coronary computed tomography angiography. RESULTS: Twenty-six (43%) participants reported at least one ACE and five (8%) reported ≥4 ACEs. A higher ACEs sum score was associated with lower endothelium-independent CFR (r partial (rp) = -0.347, p = .01) and endothelium-dependent CFR (rp = -0.278, p = .04), adjusting for age, body mass index, perceived stress and segment stenosis score. In exploratory analyses, participants with ≥4 ACEs had lower endothelium-independent CFR (rp = -0.419, p = .001) and endothelium-dependent CFR (rp = -0.278, p = .04), than those with <4 ACEs. Endothelium-dependent CFR was higher in physicians with burnout than in controls (rp = 0.277, p = .04). No significant interaction emerged between burnout and ACEs for CFR. CONCLUSION: The findings suggest an independent association between ACEs and CFR in male physicians and emphasize the nuanced relationship between early life stressors, professional stress, and cardiovascular health.


Assuntos
Esgotamento Profissional , Médicos , Humanos , Masculino , Esgotamento Profissional/psicologia , Esgotamento Profissional/fisiopatologia , Adulto , Estudos Transversais , Pessoa de Meia-Idade , Médicos/psicologia , Experiências Adversas da Infância/estatística & dados numéricos , Experiências Adversas da Infância/psicologia , Circulação Coronária/fisiologia , Inquéritos e Questionários , Estresse Psicológico/psicologia , Estresse Psicológico/fisiopatologia
7.
Eur Heart J Cardiovasc Imaging ; 25(7): 986-995, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38376985

RESUMO

AIMS: Dynamic myocardial computed tomography (CT) perfusion (DM-CTP) can, in combination with coronary CT angiography (CCTA), provide anatomical and functional evaluation of coronary artery disease (CAD). However, normal values of myocardial blood flow (MBF) are needed to identify impaired myocardial blood supply in patients with suspected CAD. We aimed to establish normal values for MBF measured using DM-CTP, to assess the effects of age and sex, and to assess regional distribution of MBF. METHODS AND RESULTS: A total of 82 healthy individuals (46 women) aged 45-78 years with normal coronary arteries by CCTA underwent either rest and adenosine stress DM-CTP (n = 30) or adenosine-induced stress DM-CTP only (n = 52). Global and segmental MBF were assessed. Global MBF at rest and during stress were 0.93 ± 0.42 and 3.58 ± 1.14 mL/min/g, respectively. MBF was not different between the sexes (P = 0.88 at rest and P = 0.61 during stress), and no correlation was observed between MBF and age (P = 0.08 at rest and P = 0.82 during stress). Among the 16 myocardial segments, significant intersegmental differences were found (P < 0.01), which was not related to age, sex, or coronary dominance. CONCLUSION: MBF assessed by DM-CTP in healthy individuals with normal coronary arteries displays significant intersegmental heterogeneity which does not seem to be affected by age, sex, or coronary dominance. Normal values of MBF may be helpful in the clinical evaluation of suspected myocardial ischaemia using DM-CTP.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Circulação Coronária , Imagem de Perfusão do Miocárdio , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Valores de Referência , Imagem de Perfusão do Miocárdio/métodos , Angiografia Coronária/métodos , Circulação Coronária/fisiologia , Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Fatores Etários , Fatores Sexuais , Tomografia Computadorizada por Raios X/métodos , Velocidade do Fluxo Sanguíneo/fisiologia
8.
J Nucl Cardiol ; 34: 101825, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38387736

RESUMO

BACKGROUND: It is clinically needed to explore a more efficient imaging protocol for single photon emission computed tomography (SPECT) myocardial blood flow (MBF) quantitation derived from cadmium zinc telluride (CZT) SPECT camera for the routine clinical utilization. METHODS: One hundred and twenty patients with matched clinical characteristics and angiographic findings who completed one-day rest/stress SPECT imaging with either the intermittently sequential imaging (ISI) protocol (two dynamic and two electrocardiography (ECG)-gated scans) or the continuous rapid imaging (CRI) protocol (two dynamic/ECG-gated scans) were included. MBF quantitation adopted residual activity correction (RAC) to correct for rest residual activity (RRA) in the stress dynamic SPECT scan for the detection of flow-limited coronary artery disease. RESULTS: The CRI protocol reduced about 6.2 times shorter than the ISI protocol (25.5 min vs 157.6 min), but slightly higher than the RRA (26.7% ± 3.6% vs 22.3% ± 4.9%). With RAC, both protocols demonstrated close stress MBF (2.18 ± 1.13 vs 2.05 ± 1.10, P > 0.05) and myocardial flow reserve (MFR) (2.42 ± 1.05 vs 2.48 ± 1.11, P > 0.05) to deliver comparable diagnostic performance (sensitivity = 82.1%-92.3%, specificity = 81.2%-91.2%). Myocardial perfusion and left ventricular function overall showed no significant difference (all P > 0.26). CONCLUSION: One-day rest/stress SPECT with the CRI protocol and rest RAC is feasible to warrant the diagnostic performance of MBF quantitation with a shortened examination time and enhanced patient comfort. Further evaluation on the impact of extracardiac activity to regional MBF and perfusion pattern is required. Additional evaluation is needed in a patient population that is typical of those referred for SPECT MPI, including those with known or suspected coronary microvascular disease.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Cádmio , Estudos de Viabilidade , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Telúrio , Zinco
9.
J Nucl Cardiol ; 32: 101796, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38278706

RESUMO

BACKGROUND: Differences in tracer characteristics may influence the interpretation of positron emission tomography myocardial perfusion imaging (MPI). We compare the reading of MPIs with a low-extraction retention tracer (82Rb) and a high-extraction non-retention tracer (15O-water) in a selected cohort of patients with known coronary artery disease (CAD). METHODS: Thirty-nine patients with known CAD referred to 82Rb MPI due to angina underwent rest and stress imaging with both tracers and experienced MPI readers provided blinded consensus reads of all studies. In addition, a comparison of regional and global quantitative measures of perfusion was performed. RESULTS: The results showed 74 % agreement in the reading of 82Rb and 15O-water MPI for regional reversible ischemia and global disease, and 82 % agreement for regional irreversible ischemia. The 15O-water MPI identified more cases of global disease (n = 12 (15O-water) vs n = 4 (82Rb), p = 0.03), whereas differences in reversible ischemia (n = 22 vs n = 16, p = 0.11) and, irreversible ischemia (n = 8 vs n = 11, p = 0.45) were not significant. The correlation between myocardial blood flow measured using the two tracers was similar to previous studies (R2 = 0.78) with wide limits of agreement (-0.93 to 0.84 ml/g/min). CONCLUSIONS: Agreement between consensus readings of 82Rb and 15O-water MPI was good in patients with known CAD. In this limited size study, no significant differences in the identification of reversible and irreversible ischemia found, whereas 15O-water MPI had a higher positive rate for suspected global disease.


Assuntos
Isquemia , Radioisótopos de Oxigênio , Tomografia por Emissão de Pósitrons , Humanos , Radioisótopos de Rubídio
10.
J Magn Reson Imaging ; 59(4): 1258-1266, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37491887

RESUMO

BACKGROUND: Determination of myocardial blood flow (MBF) with MRI is usually performed with dynamic contrast enhanced imaging (MBFDCE ). MBF can also be determined from coronary sinus blood flow (MBFCS ), which has the advantage of being a noncontrast technique. However, comparative studies of MBFDCE and MBFCS in large cohorts are lacking. PURPOSE: To compare MBFCS and MBFDCE in a large cohort. STUDY TYPE: Prospective, sequence-comparison study. POPULATION: 147 patients with type 2 diabetes mellitus (age: 56+/-12 years; 106 male; diabetes duration: 12.9+/-8.1 years), and 25 age-matched controls. FIELD STRENGTH/SEQUENCES: 1.5 Tesla scanner. Saturation recovery sequence for MBFDCE vs. phase-contrast gradient-echo pulse sequence (free-breathing) for MBFCS . ASSESSMENT: MBFDCE and MBFCS were determined at rest and during coronary dilatation achieved by administration of adenosine at 140 µg/kg/min. Myocardial perfusion reserve (MPR) was calculated as the stress/rest ratio of MBF values. Coronary sinus flow was determined twice in the same imaging session for repeatability assessment. STATISTICAL TESTS: Agreement between MBFDCE and MBFCS was assessed with Bland and Altman's technique. Repeatability was determined from single-rater random intraclass and repeatability coefficients. RESULTS: Rest and stress flows, including both MBFDCE and MBFCS values, ranged from 33 to 146 mL/min/100 g and 92 to 501 mL/min/100 g, respectively. Intraclass and repeatability coefficients for MBFCS were 0.95 (CI 0.90; 0.95) and 5 mL/min/100 g. In Bland-Altman analysis, mean bias at rest was -1.1 mL/min/100 g (CI -3.1; 0.9) with limits of agreement of -27 and 24.8 mL/min/100 g. Mean bias at stress was 6.3 mL/min/100 g (CI -1.1; 14.1) with limits of agreement of -86.9 and 99.9. Mean bias of MPR was 0.11 (CI: -0.02; 0.23) with limits of agreement of -1.43 and 1.64. CONCLUSION: MBF may be determined from coronary sinus blood flow, with acceptable bias, but relatively large limits of agreement, against the reference of MBFDCE . LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Seio Coronário , Diabetes Mellitus Tipo 2 , Imagem de Perfusão do Miocárdio , Adulto , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Circulação Coronária/fisiologia , Seio Coronário/diagnóstico por imagem , Diabetes Mellitus Tipo 2/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Estudos Prospectivos , Feminino
11.
Eur J Nucl Med Mol Imaging ; 51(6): 1632-1638, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38105304

RESUMO

PURPOSE: To prospectively compare changes in myocardial blood flow (MBF) and myocardial flow reserve (MFR) in multivessel coronary artery disease (MVCAD) patients undergoing incomplete revascularization (IR) versus complete revascularization (CR) by coronary artery bypass grafting (CABG). METHODS: Seven male patients (age 68 ± 9 years) with MVCAD underwent myocardial perfusion PET/CT with [13N]ammonia before and at least 4 months after CABG. Segmental resting and stress MBF as well as MFR were measured. Resting and during stress left ventricle ejection fraction (LVEF) were also calculated. RESULTS: Three patients (43%) underwent CR and four (57%) IR. Among 119 myocardial segments, 101 (85%) were revascularized, and 18 (15%) were not. After CABG, stress MBF (mL/min/gr) and MFR are significantly increased in all myocardial segments, with a greater increase in the revascularized segments (p = 0.013). In both groups, LVEF significantly decreased during stress at baseline PET (p = 0.04), but not after CABG. CONCLUSION: Stress MBF and MFR significantly improve after CABG in both revascularized and not directly revascularized myocardial segments. IR strategy may be considered in patients with high surgical risk for CR.


Assuntos
Ponte de Artéria Coronária , Circulação Coronária , Coração , Imagem de Perfusão do Miocárdio , Miocárdio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Coração/diagnóstico por imagem , Miocárdio/metabolismo , Projetos Piloto , Função Ventricular Esquerda
12.
Magn Reson Med ; 91(1): 118-132, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37667643

RESUMO

PURPOSE: To investigate and mitigate the influence of physiological and acquisition-related parameters on myocardial blood flow (MBF) measurements obtained with myocardial Arterial Spin Labeling (myoASL). METHODS: A Flow-sensitive Alternating Inversion Recovery (FAIR) myoASL sequence with bSSFP and spoiled GRE (spGRE) readout is investigated for MBF quantification. Bloch-equation simulations and phantom experiments were performed to evaluate how variations in acquisition flip angle (FA), acquisition matrix size (AMS), heart rate (HR) and blood T 1 $$ {\mathrm{T}}_1 $$ relaxation time ( T 1 , B $$ {\mathrm{T}}_{1,B} $$ ) affect quantification of myoASL-MBF. In vivo myoASL-images were acquired in nine healthy subjects. A corrected MBF quantification approach was proposed based on subject-specific T 1 , B $$ {\mathrm{T}}_{1,B} $$ values and, for spGRE imaging, subtracting an additional saturation-prepared baseline from the original baseline signal. RESULTS: Simulated and phantom experiments showed a strong dependence on AMS and FA ( R 2 $$ {R}^2 $$ >0.73), which was eliminated in simulations and alleviated in phantom experiments using the proposed saturation-baseline correction in spGRE. Only a very mild HR dependence ( R 2 $$ {R}^2 $$ >0.59) was observed which was reduced when calculating MBF with individual T 1 , B $$ {\mathrm{T}}_{1,B} $$ . For corrected spGRE, in vivo mean global spGRE-MBF ranged from 0.54 to 2.59 mL/g/min and was in agreement with previously reported values. Compared to uncorrected spGRE, the intra-subject variability within a measurement (0.60 mL/g/min), between measurements (0.45 mL/g/min), as well as the inter-subject variability (1.29 mL/g/min) were improved by up to 40% and were comparable with conventional bSSFP. CONCLUSION: Our results show that physiological and acquisition-related factors can lead to spurious changes in myoASL-MBF if not accounted for. Using individual T 1 , B $$ {\mathrm{T}}_{1,B} $$ and a saturation-baseline can reduce these variations in spGRE and improve reproducibility of FAIR-myoASL against acquisition parameters.


Assuntos
Circulação Coronária , Imagem de Perfusão do Miocárdio , Humanos , Reprodutibilidade dos Testes , Circulação Coronária/fisiologia , Miocárdio , Frequência Cardíaca , Imagens de Fantasmas , Imagem de Perfusão do Miocárdio/métodos
13.
Int J Cardiol ; 395: 131392, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37748522

RESUMO

BACKGROUND: Ischemia with no obstructive coronary arteries (INOCA), a chronic disorder with a poor prognosis, remains challenging to diagnose. 13N-ammonia positron emission tomography (13NH3 PET), which can quantify microcirculation, is its most reliable detection method. We aimed to investigate the differences in 13NH3 PET findings between INOCA and coronary artery disease (CAD). METHODS: Overall, consecutive 433 patients with known or suspected CAD underwent adenosine-stress 13NH3 PET. Based on the European Society of Cardiology guidelines, INOCA was defined as typical angina without coronary stenosis (INOCA n = 45, CAD n = 293, no CAD n = 95). Papillary muscle ischemia (PMI) and global myocardial flow reserve (MFR) were examined as microvascular injuries using 13NH3 PET. RESULTS: PMI was observed significantly more frequently in patients with INOCA than in those with CAD (40.0% vs. 11.6%, respectively; p = 0.02). Global MFR (1.84 ± 0.54 vs. 2.08 ± 0.66, respectively; p < 0.0001) and reactive hyperemia index were significantly lower in patients with INOCA than in those with CAD. Forty-five major adverse cardiac events (MACE) were recorded in a median follow-up time of 827 days. Kaplan-Meier analysis revealed that the survival rate worsened in patients with INOCA and PMI (log-rank test, p = 0.001). In the Cox proportional hazards model, PMI was an independent predictive factor for MACE (odds ratio, 4.16; 95% confidence interval, 2.13-8.15; p < 0.0001). CONCLUSIONS: PMI presence and decreased MFR were 13NH3 PET findings characteristic of INOCA. 13NH3 PET can be used to monitor the treatment course.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Imagem de Perfusão do Miocárdio , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Amônia , Tomografia por Emissão de Pósitrons/métodos , Angiografia Coronária/métodos , Isquemia , Imagem de Perfusão do Miocárdio/métodos
14.
BMC Med ; 21(1): 477, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-38041159

RESUMO

BACKGROUND: As a professional group, physicians are at increased risk of burnout and job stress, both of which are associated with an increased risk of coronary heart disease that is at least as high as that of other professionals. This study aimed to examine the association of burnout and job stress with coronary microvascular function, a predictor of major adverse cardiovascular events. METHODS: Thirty male physicians with clinical burnout and 30 controls without burnout were included. Burnout was assessed with the Maslach Burnout Inventory and job stress with the effort-reward imbalance and overcommitment questionnaire. All participants underwent myocardial perfusion positron emission tomography to quantify endothelium-dependent (cold pressor test) and endothelium-independent (adenosine challenge) coronary microvascular function. Burnout and job stress were regressed on coronary flow reserve (primary outcome) and two additional measures of coronary microvascular function in the same model while adjusting for age and body mass index. RESULTS: Burnout and job stress were significantly and independently associated with endothelium-dependent microvascular function. Burnout was positively associated with coronary flow reserve, myocardial blood flow response, and hyperemic myocardial blood flow (r partial = 0.28 to 0.35; p-value = 0.008 to 0.035). Effort-reward ratio (r partial = - 0.32 to - 0.38; p-value = 0.004 to 0.015) and overcommitment (r partial = - 0.30 to - 0.37; p-value = 0.005 to 0.022) showed inverse associations with these measures. CONCLUSIONS: In male physicians, burnout and high job stress showed opposite associations with coronary microvascular endothelial function. Longitudinal studies are needed to show potential clinical implications and temporal relationships between work-related variables and coronary microvascular function. Future studies should include burnout and job stress for a more nuanced understanding of their potential role in cardiovascular health.


Assuntos
Esgotamento Profissional , Estresse Ocupacional , Médicos , Humanos , Masculino , Estudos Transversais , Satisfação no Emprego , Esgotamento Profissional/epidemiologia , Esgotamento Psicológico , Inquéritos e Questionários
15.
Front Radiol ; 3: 1214521, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38105799

RESUMO

Rationale and objectives: We aimed to evaluate the impact of four-dimensional noise reduction filtering using a four-dimensional similarity filter (4D-SF) on radiation dose reduction in dynamic myocardial computed tomography perfusion (CTP). Materials and methods: Forty-three patients who underwent dynamic myocardial CTP using 320-row computed tomography (CT) were included in the study. The original images were reconstructed using iterative reconstruction (IR). Three different CTP datasets with simulated noise, corresponding to 25%, 50%, and 75% reduction of the original dose (300 mA), were reconstructed using a combination of IR and 4D-SF. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were assessed, and CT-derived myocardial blood flow (CT-MBF) was quantified. The results were compared between the original and simulated images with radiation dose reduction. Results: The median SNR (first quartile-third quartile) at the original, 25%-, 50%-, and 75%-dose reduced-simulated images with 4D-SF was 8.3 (6.5-10.2), 16.5 (11.9-21.7), 15.6 (11.0-20.1), and 12.8 (8.8-18.1) and that of CNR was 4.4 (3.2-5.8), 6.7 (4.6-10.3), 6.6 (4.3-10.1), and 5.5 (3.5-9.1), respectively. All the dose-reduced-simulated CTPs with 4D-SF had significantly higher image quality scores in SNR and CNR than the original ones (25%-, 50%-, and 75%-dose reduced vs. original images, p < 0.05, in each). The CT-MBF in 75%-dose reduced-simulated CTP was significantly lower than 25%-, 50%- dose-reduced-simulated, and original CTPs (vs. 75%-dose reduced-simulated images, p < 0.05, in each). Conclusion: 4D-SF has the potential to reduce the radiation dose associated with dynamic myocardial CTP imaging by half, without impairing the robustness of MBF quantification.

16.
Artigo em Inglês | MEDLINE | ID: mdl-37999656

RESUMO

BACKGROUND: Positron emission tomography (PET) has demonstrated utility for diagnostic and prognostic assessment of cardiac allograft vasculopathy (CAV) but has not been evaluated in the first year after transplant. OBJECTIVES: The authors sought to evaluate CAV at 1 year by PET myocardial blood flow (MBF) quantification. METHODS: Adults at 2 institutions enrolled between January 2018 and March 2021 underwent prospective 3-month (baseline) and 12-month (follow-up) post-transplant PET, endomyocardial biopsy, and intravascular ultrasound examination. Epicardial CAV was assessed by intravascular ultrasound percent intimal volume (PIV) and microvascular CAV by endomyocardial biopsy. RESULTS: A total of 136 PET studies from 74 patients were analyzed. At 12 months, median PIV increased 5.6% (95% CI: 3.6%-7.1%) with no change in microvascular CAV incidence (baseline: 31% vs follow-up: 38%; P = 0.406) and persistent microvascular disease in 13% of patients. Median capillary density increased 30 capillaries/mm2 (95% CI: -6 to 79 capillaries/mm2). PET myocardial flow reserve (2.5 ± 0.7 vs 2.9 ± 0.8; P = 0.001) and stress MBF (2.7 ± 0.6 vs 2.9 ± 0.6; P = 0.008) increased, and coronary vascular resistance (CVR) (49 ± 13 vs 47 ± 11; P = 0.214) was unchanged. At 12 months, PET and PIV had modest correlation (stress MBF: r = -0.35; CVR: r = 0.33), with lower stress MBF and higher CVR across increasing PIV tertiles (all P < 0.05). Receiver-operating characteristic curves for CAV defined by upper-tertile PIV showed areas under the curve of 0.74 for stress MBF and 0.73 for CVR. CONCLUSIONS: The 1-year post-transplant PET MBF is associated with epicardial CAV, supporting potential use for early noninvasive CAV assessment. (Early Post Transplant Cardiac Allograft Vasculopahty [ECAV]; NCT03217786).

17.
J Nucl Cardiol ; 30(6): 2790-2802, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37789106

RESUMO

BACKGROUND: 82Rb PET and [15O]H2O PET are both validated tracers for myocardical perfusion imaging but have not previously been compared clinically. During our site's transition from 82Rb to [15O]H2O PET, we performed a head-to-head comparison in a mixed population with suspected ischemic heart disease. METHODS: A total of 37 patients referred for perfusion imaging due to suspicion of coronary stenosis were examined with both 82Rb and [15O]H2O PET on the same day in rest and during adenosine-induced stress. The exams were rated by two blinded readers as normal, regional ischemia, globally reduced myocardial perfusion, or myocardial scarring. For [15O]H2O PET, regional ischemia was defined as two neighboring segments with average stress perfusion ≤ 2.3 mL/(min·g). Further, we evaluated a total perfusion deficit (TPD) of ≥ 10% as a more conservative marker of ischemia. RESULTS: [15O]H2O PET identified more patients with regional ischemia: 17(46%) vs 9(24%), agreement: 59% corresponding to a Cohen's kappa of .31 [95%CI .08-.53], (P < .001). Using the more conservative TPD ≥ 10%, the agreement increased to 86% corresponding to a kappa of .62 [95%CI .33-.92], (P = .001). For the subgroup of patients with no known heart disease (n = 18), the agreement was 94%. Interrater agreement was 95% corresponding to a kappa of .89 [95%CI .74-1.00] (P < .001). CONCLUSIONS: In clinical transition from 82Rb to [15O]H2O PET, it is important to take into account the higher frequency of patients with regional ischemia detected by [15O]H2O PET.


Assuntos
Doença da Artéria Coronariana , Isquemia Miocárdica , Imagem de Perfusão do Miocárdio , Humanos , Estudos Prospectivos , Isquemia Miocárdica/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Isquemia , Perfusão , Imagem de Perfusão do Miocárdio/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária
18.
EJNMMI Res ; 13(1): 87, 2023 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-37752344

RESUMO

BACKGROUND: Composite invasive and non-invasive data consistently demonstrate that resting myocardial blood flow (rMBF) in regions of known transmural myocardial scar (TMS) converge on a value of ~ 0.30 mL/min/g or lower. This value has been confirmed using the 3 most common myocardial perfusion agents (13N, 15O-H2O and 82Rb) incorporating various kinetic models on older 2D positron emission tomography (PET) systems. Thus, rMBF in regions of TMS can serve as a reference "truth" to evaluate low-end accuracy of various PET systems and software packages (SWPs). Using 82Rb on a contemporary 3D-PET-CT system, we sought to determine whether currently available SWP can accurately and precisely measure rMBF in regions of known TMS. RESULTS: Median rMBF (in mL/min/g) and COV in regions of TMS were 0.71 [IQR 0.52-1.02] and 0.16 with 4DM; 0.41 [0.34-0.54] and 0.10 with 4DM-FVD; 0.66 [0.51-0.85] and 0.11 with Cedars; 0.51 [0.43-0.61] and 0.08 with Emory-Votaw; 0.37 [0.30-0.42], 0.07 with Emory-Ottawa, and 0.26 [0.23-0.32], COV 0.07 with HeartSee. CONCLUSIONS: SWPs varied widely in low end accuracy based on measurement of rMBF in regions of known TMS. 3D PET using 82Rb and HeartSee software accurately (0.26 mL/min/g, consistent with established values) and precisely (COV = 0.07) quantified rMBF in regions of TMS. The Emory-Ottawa software yielded the next-best accuracy (0.37 mL/min/g), though rMBF was higher than established gold-standard values in ~ 5% of the resting scans. 4DM, 4DM-FDV, Cedars and Emory-Votaw SWP consistently resulted values higher than the established gold standard (0.71, 0.41, 0.66, 0.51 mL/min/g, respectively), with higher interscan variability (0.16, 0.11, 0.11, and 0.09, respectively). TRIAL REGISTRATION: clinicaltrial.gov, NCT05286593, Registered December 28, 2021, https://clinicaltrials.gov/ct2/show/NCT05286593 .

19.
Circulation ; 148(15): 1138-1153, 2023 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-37746744

RESUMO

BACKGROUND: Type 2 diabetes (T2D) is associated with an increased risk of left ventricular dysfunction after aortic valve replacement (AVR) in patients with severe aortic stenosis (AS). Persistent impairments in myocardial energetics and myocardial blood flow (MBF) may underpin this observation. Using phosphorus magnetic resonance spectroscopy and cardiovascular magnetic resonance, this study tested the hypothesis that patients with severe AS and T2D (AS-T2D) would have impaired myocardial energetics as reflected by the phosphocreatine to ATP ratio (PCr/ATP) and vasodilator stress MBF compared with patients with AS without T2D (AS-noT2D), and that these differences would persist after AVR. METHODS: Ninety-five patients with severe AS without coronary artery disease awaiting AVR (30 AS-T2D and 65 AS-noT2D) were recruited (mean, 71 years of age [95% CI, 69, 73]; 34 [37%] women). Thirty demographically matched healthy volunteers (HVs) and 30 patients with T2D without AS (T2D controls) were controls. One month before and 6 months after AVR, cardiac PCr/ATP, adenosine stress MBF, global longitudinal strain, NT-proBNP (N-terminal pro-B-type natriuretic peptide), and 6-minute walk distance were assessed in patients with AS. T2D controls underwent identical assessments at baseline and 6-month follow-up. HVs were assessed once and did not undergo 6-minute walk testing. RESULTS: Compared with HVs, patients with AS (AS-T2D and AS-noT2D combined) showed impairment in PCr/ATP (mean [95% CI]; HVs, 2.15 [1.89, 2.34]; AS, 1.66 [1.56, 1.75]; P<0.0001) and vasodilator stress MBF (HVs, 2.11 mL min g [1.89, 2.34]; AS, 1.54 mL min g [1.41, 1.66]; P<0.0001) before AVR. Before AVR, within the AS group, patients with AS-T2D had worse PCr/ATP (AS-noT2D, 1.74 [1.62, 1.86]; AS-T2D, 1.44 [1.32, 1.56]; P=0.002) and vasodilator stress MBF (AS-noT2D, 1.67 mL min g [1.5, 1.84]; AS-T2D, 1.25 mL min g [1.22, 1.38]; P=0.001) compared with patients with AS-noT2D. Before AVR, patients with AS-T2D also had worse PCr/ATP (AS-T2D, 1.44 [1.30, 1.60]; T2D controls, 1.66 [1.56, 1.75]; P=0.04) and vasodilator stress MBF (AS-T2D, 1.25 mL min g [1.10, 1.41]; T2D controls, 1.54 mL min g [1.41, 1.66]; P=0.001) compared with T2D controls at baseline. After AVR, PCr/ATP normalized in patients with AS-noT2D, whereas patients with AS-T2D showed no improvements (AS-noT2D, 2.11 [1.79, 2.43]; AS-T2D, 1.30 [1.07, 1.53]; P=0.0006). Vasodilator stress MBF improved in both AS groups after AVR, but this remained lower in patients with AS-T2D (AS-noT2D, 1.80 mL min g [1.59, 2.0]; AS-T2D, 1.48 mL min g [1.29, 1.66]; P=0.03). There were no longer differences in PCr/ATP (AS-T2D, 1.44 [1.30, 1.60]; T2D controls, 1.51 [1.34, 1.53]; P=0.12) or vasodilator stress MBF (AS-T2D, 1.48 mL min g [1.29, 1.66]; T2D controls, 1.60 mL min g [1.34, 1.86]; P=0.82) between patients with AS-T2D after AVR and T2D controls at follow-up. Whereas global longitudinal strain, 6-minute walk distance, and NT-proBNP all improved after AVR in patients with AS-noT2D, no improvement in these assessments was observed in patients with AS-T2D. CONCLUSIONS: Among patients with severe AS, those with T2D demonstrate persistent abnormalities in myocardial PCr/ATP, vasodilator stress MBF, and cardiac contractile function after AVR; AVR effectively normalizes myocardial PCr/ATP, vasodilator stress MBF, and cardiac contractile function in patients without T2D.


Assuntos
Estenose da Valva Aórtica , Diabetes Mellitus Tipo 2 , Implante de Prótese de Valva Cardíaca , Humanos , Feminino , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Diabetes Mellitus Tipo 2/complicações , Função Ventricular Esquerda/fisiologia , Vasodilatadores , Trifosfato de Adenosina , Implante de Prótese de Valva Cardíaca/efeitos adversos
20.
JACC Cardiovasc Imaging ; 16(7): 934-947, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37407125

RESUMO

BACKGROUND: Cardiac allograft vasculopathy (CAV) is a major obstacle limiting long-term graft survival. Effective noninvasive surveillance modalities reflecting both coronary artery and microvascular components of CAV are needed. OBJECTIVES: The authors evaluated the diagnostic performance of dynamic computed tomography-myocardial perfusion imaging (CT-MPI) and coronary computed tomography angiography (CCTA) for CAV. METHODS: A total of 63 heart transplantation patients underwent combined CT-MPI and CCTA plus invasive coronary angiography (ICA) with intravascular ultrasonography (IVUS) between December 2018 and October 2021. The median interval between CT-MPI and heart transplantation was 4.3 years. Peak myocardial blood flow (MBF) of the whole myocardium (MBFglobal) and minimum MBF (MBFmin) among the 16 segments according to the American Heart Association model, except the left ventricular apex, were calculated from CT-MPI. CCTA was assessed qualitatively, and the degree of coronary artery stenosis was recorded. CAV was diagnosed based on both ICA (ISHLT criteria) and IVUS. Patients were followed up for a median time of 2.3 years after CT-MPI and a median time of 5.7 years after transplantation. RESULTS: Among the 63 recipients, 35 (55.6%) had diagnoses of CAV. The median MBFglobal and MBFmin were significantly lower in patients with CAV (128.7 vs 150.4 mL/100 mL/min; P = 0.014; and 96.9 vs 122.8 mL/100 mL/min; P < 0.001, respectively). The combined use of coronary artery stenosis on CCTA and MBFmin showed the highest diagnostic performance with an area under the curve of 0.886 (sensitivity: 74.3%, specificity: 96.4%, positive predictive value: 96.3%, and negative predictive value: 75.0%). CONCLUSIONS: The combination of CT-MPI and CCTA demonstrated excellent diagnostic performance for the detection of CAV. One-stop evaluation of the coronary artery and microvascular components involved in CAV using combined CCTA and CT-MPI may be a potent noninvasive screening method for early detection of CAV.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Imagem de Perfusão do Miocárdio , Humanos , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X/métodos , Miocárdio , Aloenxertos , Perfusão , Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA