Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 195
Filtrar
1.
Int. j. odontostomatol. (Print) ; 13(3): 279-286, set. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1012423

RESUMO

ABSTRACT: The objective of this study was to compare the polymerization shrinkage of Eclipse photopolymerization resin for prosthesis based on urethane dimethacrylate (UDMA) with that of three heat-cured acrylic resins based on polymethyl methacrylate (PMMA) after the polymerization process and immersion in water. A total of 40 prostheses were fabricated on a standard metallic upper edentulous model: group 1, Eclipse; group 2, Triplex hot; group 3, Veracril; and group 4, Lucitone 199. Subsequently, the polymerization contraction was tested using a microscope in which measurements were made in micrometres at 3 points located in the middle parts of the right and left sides and the middle part of the palate at three time points once the prosthesis was completed, after 30 days of immersion in water for 8 hours a day at a temperature of 37 °C, and after cutting the prosthesis at the level of the second premolar. ANOVA revealed that the contraction of the polymerization no statistically significant differences between the groups, (P> 0.05). The type of resin and its interaction with the processing method behaves similarly for all test resins. The Veracril heat-cured resin obtained the lowest contraction value in the three measurements (mm) and the highest value was obtained with the Eclipse photopolymerization resin. The Eclipse resin exhibited no lower polymerization shrinkage compared to conventional acrylic resins based on polymethyl methacrylate (PMMA), however it was not significantly affected by immersion in water.


RESUMEN: El objetivo de este estudio fue comparar la contracción de polimerización de la resina de fotopolimerización Eclipse para prótesis basadas en dimetacrilato de uretano (UDMA) con la de tres resinas acrílicas curadas con calor a base de polimetacrilato de metilo (PMMA) después del proceso de polimerización e inmersión en agua. Se fabricaron un total de 40 prótesis en un modelo edéntulo superior metálico estándar: grupo 1, Eclipse; grupo 2, triplex caliente; grupo 3, veracril; y grupo 4, Lucitone 199. Posteriormente, la contracción de la polimerización se probó utilizando un microscopio en el que se realizaron mediciones en micrometros en 3 puntos ubicados en las partes medias de los lados derecho e izquierdo y la parte media del paladar en tres puntos de tiempo una vez la prótesis se completó, después de 30 días de inmersión en agua durante 8 horas al día a una temperatura de 37 °C, y después de cortar la prótesis a nivel del segundo premolar. ANOVA reveló que la contracción de la polimerización no presenta diferencias estadísticamente significativas entre los grupos, (P> 0,05). El tipo de resina y su interacción con el método de procesamiento se comportan de manera similar para todas las resinas de prueba. La resina curada con calor Veracril obtuvo el valor de contracción más bajo en las tres mediciones (mm) y el valor más alto se obtuvo con la resina de fotopolimerización Eclipse. La resina Eclipse no mostró una contracción de polimerización menor en comparación con las resinas acrílicas convencionales basadas en polimetilmetacrilato (PMMA), sin embargo, no se vio afectada significativamente por la inmersión en agua.


Assuntos
Resinas Compostas/química , Cimentos de Resina/química , Análise do Estresse Dentário/métodos , Bases de Dentadura , Polimerização , Resinas Acrílicas , Técnicas In Vitro , Hidrogel de Polietilenoglicol-Dimetacrilato , Análise do Estresse Dentário/instrumentação
2.
Dental press j. orthod. (Impr.) ; 23(6): 64-72, Nov.-Dec. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-975025

RESUMO

Abstract Objective: To assess the short-term effect of two in vitro erosive challenge protocols on the bond strength of metal orthodontic brackets on bovine enamel. Methods: Sixty bovine incisors were selected and randomly divided into six groups: AS7 (artificial saliva - 7 days, Control Group); CC7 (Coca-Cola™ - 7 days); LJ7 (lime juice - 7 days); AS30 (artificial saliva - 30 days, Control Group); CC30 (Coca-Cola™ - 30 days); LJ30 (lime juice - 30 days). Microhardness testing was performed prior to the erosive challenge to verify the standardization of samples. Immersion was performed 4x/day for five minutes, for either 7 or 30 days. After immersions were concluded, the brackets were bonded and shear bond strength was assessed after 48 hours. The Adhesive Remnant Index (ARI) was also assessed. Data were analyzed by two-way ANOVA, followed by Tukey's post-hoc and Student's t test for paired samples, and the Kruskal-Wallis non-parametric test (α = 5%). Results: The mean and standard deviation of microhardness testing of total samples were 281.89 ± 44.51 KHN. There was no statistically significant difference in shear bond strength for the time factor (7 or 30 days; F5.54= 0.105; p = 0.901). However, there was a statistically significant difference for the solution factor (F5.54= 6.671; p = 0.003). These differences occurred among solutions of Saliva x Coca-Cola™ (p = 0.003) and Coca-Cola™ x Lime Juice (p= 0.029). The assessment of the Adhesive Remnant Index showed no significant difference between groups. Conclusions: The immersion time used in the erosion protocols did not affect the bond strength of brackets to teeth. Coca-Cola™ induced significantly higher shear bond strength values than lime juice and artificial saliva. However, the short term effects of 7/30 days in this in vitro study may not be extrapolated for in vivo ones. Clinical studies should be conducted, substantiating the laboratory results.


Resumo Objetivo: avaliar o efeito de curto prazo de dois protocolos de desafio erosivo, in vitro, na resistência adesiva de braquetes ortodônticos metálicos em esmalte bovino. Métodos: Sessenta incisivos bovinos foram selecionados e divididos aleatoriamente em seis grupos: SA7 (saliva artificial - 7 dias, Grupo Controle); CC7 (Coca-Cola® - 7 dias); SL7 (suco de limão - 7 dias); SA30 (saliva artificial - 30 dias, Grupo Controle); CC30 (Coca-Cola® - 30 dias); SL30 (suco de limão - 30 dias). Foi realizado o teste de microdureza antes do desafio erosivo, para verificar a padronização das amostras. A imersão foi realizada quatro vezes ao dia, por cinco minutos, durante 7 ou 30 dias. Finalizadas as imersões, os braquetes foram colados e, após 48 horas, foi avaliada a resistência ao cisalhamento. O Índice de Adesivo Remanescente (IAR) também foi avaliado. Para análise dos dados, foram utilizados os testes ANOVA dois fatores, seguido do post-hoc de Tukey e teste t de Student para amostras pareadas, e o teste não-paramétrico de Kruskal-Wallis (α?#8197;= 5%). Resultados: a média e o desvio-padrão do teste de microdureza das amostras totais foi igual a 281,89 ± 44,51 KHN. Não houve diferença estatisticamente significativa na resistência ao cisalhamento para o fator tempo (7 ou 30 dias; F5,54= 0,105; p= 0,901). Contudo, houve diferença estatisticamente significativa para o fator solução (F5,54=6,671; p= 0,003). Essas diferenças ocorreram entre as soluções de Saliva x Coca-Cola® (p= 0,003) e Coca-Cola® x suco de limão (p= 0,029). Ao avaliar o Índice de Adesivo Remanescente, não foi possível verificar diferença significativa entre os grupos. Conclusões: o tempo de imersão utilizado nos protocolos de erosão não afetou a resistência de união dos braquetes aos dentes. A Coca-Cola® induziu valores de resistência ao cisalhamento significativamente mais altos do que o suco de limão e a saliva artificial. No entanto, os efeitos em curto prazo de 7 e 30 dias, nesse estudo in vitro, não podem ser extrapolados para os estudos in vivo. Estudos clínicos devem ser conduzidos, fundamentando os resultados laboratoriais.


Assuntos
Animais , Bebidas/efeitos adversos , Colagem Dentária/métodos , Braquetes Ortodônticos , Esmalte Dentário , Saliva Artificial/química , Propriedades de Superfície , Fatores de Tempo , Erosão Dentária/patologia , Teste de Materiais , Bovinos , Cimentos de Resina , Ligas Dentárias/química , Resistência ao Cisalhamento , Análise do Estresse Dentário/instrumentação , Sucos de Frutas e Vegetais/efeitos adversos , Dureza , Concentração de Íons de Hidrogênio , Incisivo
3.
Braz. oral res. (Online) ; 31(supl.1): e62, Aug. 2017. graf
Artigo em Inglês | LILACS | ID: biblio-889457

RESUMO

Abstract Polymerization shrinkage stress of resin-based materials have been related to several unwanted clinical consequences, such as enamel crack propagation, cusp deflection, marginal and internal gaps, and decreased bond strength. Despite the absence of strong evidence relating polymerization shrinkage to secondary caries or fracture of posterior teeth, shrinkage stress has been associated with post-operative sensitivity and marginal stain. The latter is often erroneously used as a criterion for replacement of composite restorations. Therefore, an indirect correlation can emerge between shrinkage stress and the longevity of composite restorations or resin-bonded ceramic restorations. The relationship between shrinkage and stress can be best studied in laboratory experiments and a combination of various methodologies. The objective of this review article is to discuss the concept and consequences of polymerization shrinkage and shrinkage stress of composite resins and resin cements. Literature relating to polymerization shrinkage and shrinkage stress generation, research methodologies, and contributing factors are selected and reviewed. Clinical techniques that could reduce shrinkage stress and new developments on low-shrink dental materials are also discussed.


Assuntos
Resinas Compostas/química , Análise do Estresse Dentário/métodos , Polimerização , Cimentos de Resina/química , Lâmpadas de Polimerização Dentária , Análise do Estresse Dentário/instrumentação , Teste de Materiais
4.
Dental press j. orthod. (Impr.) ; 22(1): 82-88, Jan.-Feb. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-840206

RESUMO

ABSTRACT Introduction: Material biodegradation that occurs in the mouth may interfere in the bonding strength between the bracket and the enamel, causing lower bond strength values in vivo, in comparison with in vitro studies. Objective: To develop a prototype to measure bracket debonding force in vivo and to evaluate, in vitro, the bond strength obtained with the prototype. Methods: A original plier (3M Unitek) was modified by adding one strain gauge directly connected to its claw. An electronic circuit performed the reading of the strain gauge, and the software installed in a computer recorded the values of the bracket debonding force, in kgf. Orthodontic brackets were bonded to the facial surface of 30 bovine incisors with adhesive materials. In Group 1 (n = 15), debonding was carried out with the prototype, while tensile bond strength testing was performed in Group 2 (n = 15). A universal testing machine was used for the second group. The adhesive remnant index (ARI) was recorded. Results: According to Student’s t test (α = 0.05), Group 1 (2.96 MPa) and Group 2 (3.08 MPa) were not significantly different. ARI score of 3 was predominant in the two groups. Conclusion: The prototype proved to be reliable for obtaining in vivo bond strength values for orthodontic brackets.


RESUMO Introdução: a biodegradação de materiais que ocorre na cavidade bucal pode interferir na resistência de união entre o braquete e o esmalte, causando baixos valores de resistência de união in vivo, em comparação aos valores in vitro. Objetivo: o objetivo do presente estudo foi desenvolver um protótipo para mensurar, in vivo, a força de descolagem de braquetes e avaliar, in vitro, a resistência de união obtida com o uso do protótipo. Métodos: um alicate (3M Unitek) foi modificado por meio da adição de um extensômetro diretamente conectado à garra do alicate. Um circuito eletrônico realizou a leitura do extensômetro, e um software instalado em um computador registrou os valores de força de descolagem do braquete em kgf. Os braquetes ortodônticos foram colados com material adesivo na face vestibular de 30 dentes incisivos bovinos. No Grupo 1 (n = 15), a descolagem foi realizada com o protótipo, enquanto no Grupo 2 (n = 15) foi realizado teste de resistência de união à tração, utilizando-se uma máquina universal de ensaios. O índice de adesivo remanescente (ARI) foi analisado. Resultados: de acordo com o teste de t de Student (α = 0,05), os grupos 1 (2,96 MPa) e 2 (3,08 MPa) não foram estatisticamente diferentes. O escore 3 do ARI foi predominante nos dois grupos. Conclusão: o protótipo mostrou-se confiável para se obter, in vivo, os valores de resistência de união dos braquetes ortodônticos.


Assuntos
Animais , Braquetes Ortodônticos , Descolagem Dentária , Análise do Estresse Dentário/instrumentação , Bovinos , Adesivos , Colagem Dentária
5.
J Adhes Dent ; 18(2): 151-6, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27022644

RESUMO

PURPOSE: To evaluate the effects of three different radiation doses on the bond strengths of two different adhesive systems to enamel and dentin. MATERIALS AND METHODS: Eighty human third molars were randomly divided into four groups (n = 20) according to the radiation dose (control/no radiation, 20 Gy, 40 Gy, and 70 Gy). The teeth were sagittally sectioned into three slices: one mesial and one distal section containing enamel and one middle section containing dentin. The sections were then placed in the enamel and dentin groups, which were further divided into two subgroups (n = 10) according to the adhesive used. Three restorations were performed in each tooth (one per section) using Adper Single Bond 2 (3M ESPE) or Universal Single Bond (3M ESPE) adhesive system and Filtek Z350 XT (3M ESPE) resin composite and subjected to the microshear bond test. Data were analyzed using a two-way ANOVA followed by Tukey's test. Failure modes were examined under a stereoscopic loupe. RESULTS: Radiotherapy did not affect the bond strengths of the adhesives to either enamel or dentin. In dentin, the Universal Single Bond adhesive system showed higher bond strength values when compared with the Adper Single Bond adhesive system. More adhesive failures were observed in the enamel for all radiation doses and adhesives. CONCLUSION: Radiotherapy did not influence the bond strength to enamel or dentin, irrespective of the adhesive or radiation dose used.


Assuntos
Colagem Dentária , Esmalte Dentário/efeitos da radiação , Dentina/efeitos da radiação , Doses de Radiação , Cimentos de Resina/efeitos da radiação , Condicionamento Ácido do Dente/métodos , Adesividade , Bis-Fenol A-Glicidil Metacrilato/química , Bis-Fenol A-Glicidil Metacrilato/efeitos da radiação , Resinas Compostas/química , Resinas Compostas/efeitos da radiação , Lâmpadas de Polimerização Dentária/classificação , Cimentos Dentários/química , Cimentos Dentários/efeitos da radiação , Análise do Estresse Dentário/instrumentação , Humanos , Ácidos Fosfóricos/química , Distribuição Aleatória , Cimentos de Resina/química , Resistência ao Cisalhamento , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo
6.
J Craniomaxillofac Surg ; 43(10): 1966-73, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26616405

RESUMO

OBJECTIVES: The animal study aims to evaluate a new experimental model for measuring sole the influence of the surface characteristics independent from implant macro-design on the level of osseointegration by registering the pull-out strength needed for removal of experimental devices with different surfaces from artificial defects. MATERIAL AND METHODS: Seventy-two test bodies (36 with the FRIADENT(®) plus surface, 36 with the P15/HAp biofunctionalized surface) were inserted in six adult domestic pigs with artificial calvarial defects. The experimental devices were designed to fit in the defects leaving a gap between the test body and the local bone. After 21 days of healing, the animals were sacrificed and the test bodies were pulled out with a standardised reproducible pull-out device measuring the pull-out strength. The pull-out strength for both groups was compared. RESULTS: Twenty-one days after insertion a mean force of 412 ± 142 N for the P15/HAp group and 183 ± 105 N for the FRIADENT(®) plus group was measured for the removal of the specimens from the calvarial bone. The difference between the groups was statistically significant (p < 0.0001). CONCLUSION: The experimental set-up seems to be a suitable method when measuring the impact of implant surfaces on the early stage of osseointegration.


Assuntos
Implantes Dentários , Osseointegração/fisiologia , Cicatrização/fisiologia , Animais , Fenômenos Biomecânicos , Osso e Ossos , Retenção em Prótese Dentária , Análise do Estresse Dentário/instrumentação , Projetos Piloto , Estresse Mecânico , Propriedades de Superfície , Suínos , Titânio
7.
Pediatr Dent ; 37(4): 339-41, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26314600

RESUMO

PURPOSE: The purpose of this study was to evaluate and compare the effect of placing vertical grooves, sandblasting, and luting cements on the retention of stainless steel crowns (SSCs). METHODS: Eighty extracted primary molars were mounted in acrylic blocks. Specimens were divided into Group 1 (RelyX U200) and Group 2 (Smart Cem2). Teeth in each group were further subdivided into Subgroup A (no vertical grooves and no sandblasting), Subgroup B (vertical grooves), Subgroup C (sandblasting of crowns), and Subgroup D (vertical grooves and sandblasting of crowns). After cementation, SSCs were pulled off using a universal testing machine. One-way analysis of variance was used for statistical analyses. RESULTS: In Groups 1 and 2, the highest retentive strengths were found in Subgroup D (1,124 and 783 kPa, respectively), followed by Subgroup C (1,066 and 748 kPa, respectively), Subgroup A (762 and 356 kPa, respectively), and Subgroup B (743 and 314 kPa, respectively). Retentive strength in Group one was significantly higher than in Group two; Subgroups A and B were significantly lower than C and D. CONCLUSIONS: RelyX U200 showed higher retentive strength than Smart Cem2. Sandblasting increased the retention strength, whereas a vertical groove had no significant effect on retention.


Assuntos
Coroas , Ligas Dentárias/química , Cimentos Dentários/química , Corrosão Dentária/métodos , Retenção em Prótese Dentária/métodos , Aço Inoxidável/química , Óxido de Alumínio/química , Cimentação/métodos , Planejamento de Prótese Dentária , Análise do Estresse Dentário/instrumentação , Humanos , Teste de Materiais , Cimentos de Resina/química , Dióxido de Silício/química , Estresse Mecânico , Propriedades de Superfície
8.
Am J Orthod Dentofacial Orthop ; 148(2): 283-92, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26232837

RESUMO

INTRODUCTION: The increasing success rates for cancer patients treated with radiotherapy and the frequent occurrence of tooth loss during treatment have led to an increased demand for orthodontic treatment after radiotherapy. The aim of this study was to evaluate tooth enamel of irradiated teeth after the bonding and debonding of metal and ceramic brackets. METHODS: Ten permanent molars were cut into enamel fragments measuring 1 mm(2) and divided into an irradiated group (total dose of 60 Gy) and a nonirradiated group. The fragments were subjected to microshear testing to evaluate whether radiotherapy altered the strength of the enamel. Furthermore, 90 prepared premolars were divided into 6 groups and subgroups (n = 15): group 1, nonirradiated and nonaged; group 2, nonirradiated and aged (thermal cycled); group 3, irradiated and aged; each group was divided into 2 subgroups: metallic and ceramic brackets. After thermal cycling and radiotherapy, the brackets were bonded onto the specimens with Transbond XT (3M Unitek, Monrovia, Calif). After 24 hours, the specimens were subjected to the shear tests. Images of the enamel surfaces were classified using the adhesive remnant index. The composite resin-enamel interface was also evaluated. RESULTS: Enamel fragments subjected to radiation had lower strength than did the nonirradiated samples (P <0.05). The groups and subgroups submitted to radiation and bonded ceramic brackets had the lowest strength values. Groups 1 and 2 with metallic brackets had less adhesive on the surface, whereas groups 1 and 2 with ceramic brackets and group 3 with both metallic and ceramic brackets had more adhesive on the surfaces. On the images of the composite resin-enamel interface, resin tags were more extensive on irradiated tooth enamel. CONCLUSIONS: Radiation decreased tooth enamel strength, and the specimens treated with radiotherapy had higher frequencies of adhesive failure between the bracket and the composite resin as well as more extensive tags.


Assuntos
Cerâmica/química , Ligas Dentárias/química , Colagem Dentária , Esmalte Dentário/efeitos da radiação , Materiais Dentários/química , Braquetes Ortodônticos , Dosagem Radioterapêutica , Adesividade , Esmalte Dentário/ultraestrutura , Análise do Estresse Dentário/instrumentação , Fracionamento da Dose de Radiação , Humanos , Cura Luminosa de Adesivos Dentários , Microscopia Confocal , Microscopia Eletrônica de Varredura , Cimentos de Resina/química , Resistência ao Cisalhamento , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo
9.
Dental press j. orthod. (Impr.) ; 20(4): 51-56, July-Aug. 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-757427

RESUMO

OBJECTIVE: To assess four different chemical surface conditioning methods for ceramic material before bracket bonding, and their impact on shear bond strength and surface integrity at debonding.METHODS: Four experimental groups (n = 13) were set up according to the ceramic conditioning method: G1 = 37% phosphoric acid etching followed by silane application; G2 = 37% liquid phosphoric acid etching, no rinsing, followed by silane application; G3 = 10% hydrofluoric acid etching alone; and G4 = 10% hydrofluoric acid etching followed by silane application. After surface conditioning, metal brackets were bonded to porcelain by means of the Transbond XP system (3M Unitek). Samples were submitted to shear bond strength tests in a universal testing machine and the surfaces were later assessed with a microscope under 8 X magnification. ANOVA/Tukey tests were performed to establish the difference between groups (α= 5%).RESULTS: The highest shear bond strength values were found in groups G3 and G4 (22.01 ± 2.15 MPa and 22.83 ± 3.32 Mpa, respectively), followed by G1 (16.42 ± 3.61 MPa) and G2 (9.29 ± 1.95 MPa). As regards surface evaluation after bracket debonding, the use of liquid phosphoric acid followed by silane application (G2) produced the least damage to porcelain. When hydrofluoric acid and silane were applied, the risk of ceramic fracture increased.CONCLUSIONS: Acceptable levels of bond strength for clinical use were reached by all methods tested; however, liquid phosphoric acid etching followed by silane application (G2) resulted in the least damage to the ceramic surface.


OBJETIVO: avaliar quatro métodos de condicionamento químico da superfície cerâmica, previamente à colagem de braquetes, e seu impacto sobre a resistência ao cisalhamento e a integridade da superfície ao descolamento.MÉTODOS: quatro grupos experimentais (n = 13) foram delineados de acordo com o método de condicionamento da superfície cerâmica empregado: G1 = ácido fosfórico a 37%, seguido da aplicação de silano; G2 = ácido fosfórico líquido a 37%, seguido da aplicação de silano sem lavagem prévia do ácido; G3 = ácido fluorídrico a 10%; e G4 = ácido fluorídrico a 10%, seguido da aplicação de silano. Após o condicionamento da superfície, braquetes metálicos foram colados à porcelana utilizando-se o sistema Transbond XP (3M Unitek). As amostras foram submetidas a ensaios de resistência ao cisalhamento, em máquina de ensaio universal, e as superfícies cerâmicas foram posteriormente avaliadas em microscópio, com magnitude de 8X. Testes ANOVA/Tukey foram realizados para verificar-se a diferença entre os grupos (α = 5%).RESULTADOS: os maiores valores de resistência ao cisalhamento foram encontrados nos grupos G3 e G4 (22,01 ± 2,15MPa e 22,83 ± 3,32Mpa, respectivamente), seguidos por G1 (16,42 ± 3,61MPa) e G2 (9,29 ± 1,95MPa). Quanto à avaliação da superfície após a descolagem do braquete, a utilização de ácido fosfórico líquido seguido da aplicação de silano, sem lavagem do ácido (G2), produziu menores danos à porcelana. Quando ácido fluorídrico e silano foram aplicados, o risco de fraturar a cerâmica aumentou.CONCLUSÕES: níveis aceitáveis de resistência de união para uso clínico foram alcançados por todos os métodos testados. No entanto, o condicionamento com ácido fosfórico líquido, seguido da aplicação de silano (G2), resultou em menor dano à superfície cerâmica.


Assuntos
Condicionamento Ácido do Dente/métodos , Colagem Dentária , Braquetes Ortodônticos , Porcelana Dentária/química , Ácidos Fosfóricos/química , Silanos/química , Estresse Mecânico , Propriedades de Superfície , Teste de Materiais , Desenho de Aparelho Ortodôntico , Descolagem Dentária/métodos , Compostos de Potássio/química , Resinas Compostas/química , Cimentos de Resina/química , Ligas Dentárias/química , Resistência ao Cisalhamento , Análise do Estresse Dentário/instrumentação , Silicatos de Alumínio/química , Ácido Fluorídrico/química , Microscopia
10.
Dental press j. orthod. (Impr.) ; 20(4): 45-50, July-Aug. 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-757423

RESUMO

OBJECTIVE: The aim of this study was to assess whether repetitive opening and closure of self-ligating bracket clips can cause plastic deformation of the clip.METHODS: Three types of active/interactive ceramic self-ligating brackets (n = 20) were tested: In-Ovation C, Quicklear and WOW. A standardized controlled device performed 500 cycles of opening and closure movements of the bracket clip with proper instruments and techniques adapted as recommended by the manufacturer of each bracket type. Two tensile tests, one before and one after the repetitive cycles, were performed to assess the stiffness of the clips. To this end, a custom-made stainless steel 0.40 x 0.40 mm wire was inserted into the bracket slot and adapted to the universal testing machine (EMIC DL2000), after which measurements were recorded. On the loading portion of the loading-unloading curve of clips, the slope fitted a first-degree equation curve to determine the stiffness/deflection rate of the clip.RESULTS: The results of plastic deformation showed no significant difference among bracket types before and after the 500 cycles of opening and closure (p = 0.811). There were significant differences on stiffness among the three types of brackets (p = 0.005). The WOW bracket had higher mean values, whereas Quicklear bracket had lower values, regardless of the opening/closure cycle.CONCLUSION: Repetitive controlled opening and closure movements of the clip did not alter stiffness or cause plastic deformation.


OBJETIVO: o objetivo deste estudo foi avaliar se a abertura e o fechamento repetitivo do clipe de braquetes autoligáveis podem causar deformação plástica do clipe.MÉTODOS: três tipos de braquetes autoligáveis ativos/interativos estéticos (n = 20) foram testados: In-Ovation C, Quicklear e WOW. Um dispositivo realizou, de forma controlada e padronizada, 500 ciclos de abertura e de fechamento do clipe, com instrumentos e técnicas adequadas, tal como recomendado pelo fabricante de cada tipo de braquete. Dois ensaios de tração, um antes e um depois dos ciclos repetitivos, foram realizados para se avaliar a rigidez dos clipes. Para o ensaio de tração, um fio de 0,40 x 0,40mm de aço inoxidável foi inserido no slot do braquete e adaptado em uma máquina universal de ensaios (EMIC DL2000), sendo as medições registradas. Na porção retilínea da curva de carregamento dos clipes, a inclinação é definida por uma equação de primeiro grau, determinando o coeficiente de elasticidade (rigidez) do clipe.RESULTADOS: os resultados quanto à deformação plástica não mostraram nenhuma diferença significativa entre os tipos de braquetes, antes e depois dos 500 ciclos de abertura e de fechamento (p = 0,811). Foram encontradas diferenças significativas na rigidez entre os três tipos de braquetes (p = 0,005): o braquete WOW demonstrou valores médios mais elevados, e o braquete Quicklear demonstrou valores mais baixos, independentemente do ciclo de abertura e fechamento.CONCLUSÃO: movimentos repetitivos controlados de abertura e de fechamento do clipe não alteraram a rigidez ou causaram deformação plástica.


Assuntos
Cerâmica/química , Braquetes Ortodônticos , Desenho de Aparelho Ortodôntico , Ligas Dentárias/química , Materiais Dentários/química , Fios Ortodônticos , Aço Inoxidável/química , Estresse Mecânico , Resistência à Tração , Teste de Materiais , Maleabilidade , Análise do Estresse Dentário/instrumentação , Fenômenos Mecânicos , Módulo de Elasticidade
11.
J Craniofac Surg ; 26(7): 2196-200, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26192032

RESUMO

This study aimed to analyze the stress distribution in single implant system and to evaluate the compatibility of an in vitro model with finite element (FE) model. The in vitro model consisted of Brånemark implant; multiunit set abutment of 5 mm height; metal-ceramic screw-retained crown, and polyurethane simulating the bone. Deformations were recorded in the peri-implant region in the mesial and distal aspects, after an axial 300 N load application at the center of the occlusal aspect of the crown, using strain gauges. This in vitro model was scanned with micro CT to design a three-dimensional FE model and the strains in the peri-implant bone region were registered to check the compatibility between both models. The FE model was used to evaluate stress distribution in different parts of the system. The values obtained from the in vitro model (20-587 µÎµ) and the finite element analysis (81-588 µÎµ) showed agreement among them. The highest stresses because of axial and oblique load, respectively were 5.83 and 40 MPa for the cortical bone, 55 and 1200 MPa for the implant, and 80 and 470 MPa for the abutment screw. The FE method proved to be effective for evaluating the deformation around single implant. Oblique loads lead to higher stress concentrations.


Assuntos
Implantes Dentários para Um Único Dente , Análise de Elementos Finitos , Imageamento Tridimensional/métodos , Silicatos de Alumínio/química , Fenômenos Biomecânicos , Ligas de Cromo/química , Simulação por Computador , Coroas , Projeto do Implante Dentário-Pivô , Porcelana Dentária/química , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário/instrumentação , Humanos , Mandíbula/fisiologia , Teste de Materiais , Ligas Metalo-Cerâmicas/química , Modelos Anatômicos , Modelos Biológicos , Compostos de Potássio/química , Estresse Mecânico , Microtomografia por Raio-X/métodos
12.
J Prosthet Dent ; 114(4): 513-6, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26050025

RESUMO

STATEMENT OF PROBLEM: Several aftermarket abutments are available for a commonly used internal hexagonal connection implant. However, their load to failure performance is unknown when compared with the manufacturer's abutment. PURPOSE: The purpose of this in vitro study was to conduct a load to failure comparison of 5 different titanium abutments (manufacturer's and aftermarket) for cement-retained restorations used on an implant with an internal hexagon connection. MATERIAL AND METHODS: Five implants (Tapered Screw-Vent, 4.1×11.5 mm; Zimmer Dental) were individually secured in a loading apparatus, and 3 abutment specimens of each of the 5 different titanium abutments (Atlantis, AstraTech TiDesign, Legacy Straight Contoured, Inclusive Custom, and Zimmer PSA) (n=15 total) were loaded at a 30-degree angle until fracture of the implant abutment complex. Data for load to fracture were compared with analysis of variance and a Tukey-Kramer post hoc test (α=.05). RESULTS: Significant differences were noted between the fracture loads of some abutment pairs; Atlantis-AstraTech TiDesign, Atlantis-Legacy Straight Contoured, AstraTech TiDesign-Legacy Straight Contoured, Inclusive Custom-AstraTech TiDesign, and Inclusive Custom-Legacy Straight Contoured (P<.05). The highest overall resistance to fracture was achieved by the Legacy Straight Contoured Abutment, which was significantly greater than all other aftermarket abutments (P<.05). Tested abutments fractured at an average of 649.17 N. The Zimmer PSA abutment was the only abutment that showed no fracture of any of the components before implant failure. CONCLUSION: When comparing manufacturer's versus aftermarket brands, the manufacturer's abutment (Zimmer PSA) was the only abutment without fracture of any of the components. Aftermarket brands experienced screw fractures, which could result in further clinical prosthetic complications. The clinical implications of these findings need further investigation.


Assuntos
Dente Suporte , Projeto do Implante Dentário-Pivô , Materiais Dentários/química , Falha de Restauração Dentária , Titânio/química , Coroas , Análise do Estresse Dentário/instrumentação , Humanos , Teste de Materiais , Estresse Mecânico
13.
Braz. dent. j ; 26(3): 258-262, May-Jun/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-751869

RESUMO

In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.


Considerando os valores relativamente pequenos utilizados em odontologia para os ensaios de carregamento verticais axiais, foi desenvolvido um dispositivo de aplicação de carga (DAC) para substituir a máquina de ensaios universal (EMIC). O objetivo deste estudo foi desenvolver um DAC e compará-lo com a EMIC por meio da utilização de carregamentos axiais e não-axiais. Num bloco de poliuretano foi inserido um implante hexágono externo, o qual foi conectado a um pilar protético esteticone. Sobre o pilar protético foi parafusada uma coifa plástica e um pilar cônico foi modelado em resina acrílica, que foi moldada para a obtenção de dez enceramentos iguais que foram fundidos em níquel cromo. Quatro extensômetros foram diametralmente colados ao redor do implante. Cada corpo de prova foi submetido a cargas axiais central (C) e lateral (L) de 30 kgf, em ambos os dispositivos: G1) DAC/C; G2) DAC/L; G3) EMIC/C; G4) EMIC/L. Os dados (µε) foram analisados estatisticamente pelos testes de ANOVA para medidas repetidas e de Tukey (p<0,05). Não houve diferença estatisticamente significante entre os dispositivos DAC e EMIC, independente do tipo de carga. A aplicação de carga não-axial (NA) determinou um aumento significante de tensões ao redor do implante. Foi concluído que o DAC é uma opção confiável, a qual induz microtensão em implantes de forma semelhante à EMIC.


Assuntos
Prótese Dentária , Análise do Estresse Dentário/instrumentação
14.
J Contemp Dent Pract ; 16(2): 91-5, 2015 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-25906797

RESUMO

OBJECTIVE: This study evaluated in vitro the mechanical changes of 0.018" (0.45 mm) and 0.016 × 0.022" (0.40 × 0.55 mm) thermoactivated nickel-titanium archwires subjected to heat treatment on their distal ends. MATERIALS AND METHODS: Ten archwires in diameters 0.018" and 0.016 × 0.022" by different manufacturers Ormco, Morelli, Orthometric and Unitek were tested. Each tested archwire had an experimental side, submitted to heat treatment, and an annealing-free control. Tests for load/deflection were performed using a universal testing machine, with temperature control in the austenitic transformation phase through tempe rature-controlled chamber. The variables showed normal distribution (Kolmogorov-Smirnov), the t-student test was applied in order to observe the difference between the experi mental and control groups. Statistical significance was set at p < 0.05. RESULTS: There were no statistically significant differences between the groups. CONCLUSION: Heat treatment carried out in the region corresponding to the first molar distal region on thermoactivated nickel-titanium archwires did not influence the load/deflection values in adjacent portion.


Assuntos
Ligas Dentárias/química , Níquel/química , Fios Ortodônticos , Titânio/química , Análise do Estresse Dentário/instrumentação , Elasticidade , Temperatura Alta , Humanos , Teste de Materiais , Desenho de Aparelho Ortodôntico , Braquetes Ortodônticos , Transição de Fase , Estresse Mecânico , Propriedades de Superfície
15.
J Craniomaxillofac Surg ; 43(5): 616-23, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25865491

RESUMO

OBJECTIVES: Fractures of the atrophic edentulous mandible are a rare complication that can become severe after the insertion of dental implants. This in vitro study investigated the effects of different implant settings varying in number, diameter, and length. and the influence of a fixed bar. MATERIALS AND METHODS: In biomechanical experiments on artificial mandibles, an unmodified reference group, four implant settings with two different implants, and the effect of adding a fixed bar to these settings were tested. All specimens were loaded with incisal biting forces until failure due to fracture. RESULTS: Implants weakened all specimens significantly compared with those in the reference group. Without a fixed bar, four short and thick implants showed the best results, with high significance. With a fixed bar, four long and thin implants withstood the highest loads. The addition of fixed bars reduced the differences between the implant settings. Fixed bars did not show increased stability for all groups; however, these groups showed a higher mean strength. CONCLUSIONS: Four implants with a short and thick design should be the first choice when implants are placed without a fixed bar in an atrophic mandible. With a fixed bar, four long and thin implants should be used.


Assuntos
Implantes Dentários , Planejamento de Prótese Dentária , Arcada Edêntula/fisiopatologia , Mandíbula/fisiopatologia , Atrofia , Materiais Biocompatíveis/química , Fenômenos Biomecânicos , Força de Mordida , Ligas de Cromo/química , Projeto do Implante Dentário-Pivô , Análise do Estresse Dentário/instrumentação , Humanos , Arcada Edêntula/patologia , Mandíbula/patologia , Fraturas Mandibulares/fisiopatologia , Modelos Anatômicos , Poliuretanos/química , Estresse Mecânico
16.
J Adhes Dent ; 17(6): 505-12, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26734674

RESUMO

PURPOSE: To compare and evaluate shear bond strength of self-etching adhesives bonded to cavities prepared by diamond bur or Er,Cr:YSGG laser and the effect of prior acid etching on shear bond strength. MATERIALS AND METHODS: Ninety-six caries-free human premolars were selected and divided into 2 groups depending on mode of cavity preparation (48 teeth each). Cavities were prepared with Er,Cr:YSGG laser in group 1 and diamond burs in an air-turbine handpiece in group 2. Groups 1 and 2 were further subdivided into three subgroups of 8 teeth each, which were bonded with sixth- or seventh-generation adhesives with or without prior acid etching, followed by restoration of all samples with APX Flow. These samples were subjected to shear bond strength testing. In addition, the surface morphology of 24 samples each from groups 1 and 2 was evaluated using SEM. Data were analyzed using the Shapiro-Wilk test, one- and two-way ANOVA, the t-test, and the least significant difference test, which showed that the data were normally distributed (p > 0.05). RESULTS: The shear bond strength of adhesives in cavities prepared by Er,Cr:YSGG laser was significantly higher than in diamond bur-prepared cavities (p < 0.05). SEM analysis showed a smear-layer-free anfractuous surface on laser-ablated teeth, in contrast to conventional bur-prepared teeth. CONCLUSIONS: The Er,Cr:YSGG laser-ablated surface proved to be more receptive for adhesion than those prepared by diamond bur irrespective of the bonding agent used. Seventh-generation adhesives yielded higher shear bond strength than did sixth-generation adhesives. Prior acid etching decreased the shear bond strength of self-etching adhesives.


Assuntos
Condicionamento Ácido do Dente/métodos , Colagem Dentária , Preparo da Cavidade Dentária/instrumentação , Esmalte Dentário/ultraestrutura , Equipamentos Odontológicos de Alta Rotação , Dentina/ultraestrutura , Diamante/química , Lasers de Estado Sólido , Cimentos de Resina/química , Bis-Fenol A-Glicidil Metacrilato/química , Preparo da Cavidade Dentária/classificação , Análise do Estresse Dentário/instrumentação , Adesivos Dentinários/química , Humanos , Terapia a Laser/instrumentação , Teste de Materiais , Metacrilatos/química , Microscopia Eletrônica de Varredura , Ácidos Polimetacrílicos/química , Distribuição Aleatória , Resistência ao Cisalhamento , Camada de Esfregaço/ultraestrutura , Estresse Mecânico , Propriedades de Superfície
17.
J Prosthet Dent ; 113(2): 122-7, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25438742

RESUMO

STATEMENT OF PROBLEM: Although the use of anatomic-contour zirconia restorations has expanded in the recent past, disagreement still exists as to reliable cementation techniques and materials. PURPOSE: The purpose of this in vitro study was to compare the immediate and artificially aged shear bond strength of 2 commercially available self-adhesive resin cements to zirconia: one with silica coating and silanation as a zirconia surface treatment and the other contained a phosphate monomer, which eliminated the need for a separate primer. MATERIAL AND METHODS: Sixty composite resin rods (2.5 mm in diameter and 3 mm in length) were fabricated from a nano-optimized composite resin by using a polypropylene mold, then light polymerized with a light-emitting diode. zirconia plates (10×10×4mm) were sectioned from an yttrium-stabilized zirconia puck, sintered, and then mounted in autopolymerizing acrylic resin custom tray material. Composite resin rods were cemented to the zirconia plates with 2 different cements. The surface treatment of zirconia followed the manufacturers' instructions for each cement. The specimens were tested for shear bond strength at 3 aging conditions: immediate, after 24 hours of moist storage, and after 30 days of moist storage with 10000 thermocycles. Specimens were loaded to failure in a universal testing machine, and the data were analyzed with 2-way ANOVA (α=.05). Weibull parameters (modulus and characteristic strength) also were calculated for each group. RESULTS: Two-way ANOVA revealed that only the aging condition significantly affected the bond strength to zirconia. The cement and the interaction of the cement and aging did not significantly affect the shear bond strength to zirconia. The highest bond strength for both cements was achieved at 24 hours, whereas the lowest bond strength values were recorded in the immediate groups. CONCLUSIONS: No significant differences in bond strength to zirconia were observed between a cement with a silane priming step and an methacryloxydecyl dihydrogen phosphate-containing cement without a separate primer. Aging had a significant effect on the shear bond strength of the 2 self-adhesive resin cements to zirconia.


Assuntos
Cerâmica/química , Colagem Dentária , Materiais Dentários/química , Cimentos de Resina/química , Ítrio/química , Zircônio/química , Acrilatos/química , Materiais Revestidos Biocompatíveis/química , Resinas Compostas/química , Lâmpadas de Polimerização Dentária/classificação , Análise do Estresse Dentário/instrumentação , Humanos , Teste de Materiais , Metacrilatos/química , Microscopia Eletrônica de Varredura , Nanocompostos/química , Polimerização , Resistência ao Cisalhamento , Silanos/química , Dióxido de Silício/química , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo , Água/química
18.
J Craniomaxillofac Surg ; 43(1): 158-61, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25439088

RESUMO

OBJECTIVE: To develop Y-shaped plates with different thicknesses to be used in simulated fractures of the mandibular condyle. Ten plates were developed in Y shape, containing eight holes, and 30 synthetic polyurethane mandible replicas were developed for the study. MATERIAL AND METHODS: The load test was performed on an Instron Model 4411 universal testing machine, applying load in the mediolateral and anterior-posterior positions on the head of the condyle. Two-way ANOVA with Tukey testing with a 5% significance level was used. RESULTS: It was observed that when the load was applied in the medial-lateral plate of greater thickness (1.5 mm), it gave the highest strength, while in the anteroposterior direction, the plate with the highest resistance was of the lesser thickness (0.6 mm). A plate with a thickness of 1.5 mm was the one with the highest average value for all displacements. In the anteroposterior direction, the highest values of resistance were seen in the displacement of 15 mm. CONCLUSION: After comparing the values of the biomechanical testing found in the scientific literature, it is suggested that the use of Y plates are suitable for use in subcondylar fractures within the limitations of the study.


Assuntos
Placas Ósseas , Desenho de Equipamento , Fixação Interna de Fraturas/instrumentação , Côndilo Mandibular/lesões , Fraturas Mandibulares/cirurgia , Materiais Biocompatíveis/química , Fenômenos Biomecânicos , Análise do Estresse Dentário/instrumentação , Humanos , Côndilo Mandibular/fisiopatologia , Fraturas Mandibulares/fisiopatologia , Modelos Anatômicos , Poliuretanos/química , Estresse Mecânico , Propriedades de Superfície
19.
Angle Orthod ; 85(1): 95-101, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24901067

RESUMO

OBJECTIVE: To test for differences in loading and unloading forces delivered by six coated nickel-titanium wires and their noncoated equivalents. MATERIALS AND METHODS: From six commercial companies, 0.016-inch diameter round and 0.016 × 0.022-inch rectangular cross-section nickel-titanium wires were procured "as is": Rocky Mountain Orthodontics (Denver, Colo), TP Orthodontics (La Porte, Ind), American Orthodontics (AO; Sheboygan, Wis), G&H (Franklin, Ind), Opal Orthodontics (South Jordan, Utah), and Forestadent USA (St Louis, Mo) (round only). The wires were evaluated using a three-point bending test based on the method in ISO Standard 15841. RESULTS: No statistically significant differences (P > .05) in force values were found between coated and noncoated wires, listed by deflection in three-point bending, for these specific groups: 1 mm, TP round; 2 mm, TP round and G&H rectangular; 3 mm, G&H round and G&H rectangular; 2.5 mm,TP round and G&H rectangular; 1.5 mm, TP round, G&H round, G&H rectangular, and AO rectangular; and 0.5 mm, AO rectangular and G&H round. CONCLUSION: Some manufacturers market esthetic wires delivering forces similar to the equivalent noncoated wires, when tested according to a standard three-point bend method.


Assuntos
Materiais Revestidos Biocompatíveis/química , Ligas Dentárias/química , Níquel/química , Fios Ortodônticos , Titânio/química , Análise do Estresse Dentário/instrumentação , Estética Dentária , Humanos , Teste de Materiais , Maleabilidade , Estresse Mecânico , Propriedades de Superfície
20.
J Craniofac Surg ; 25(6): 2246-50, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25340696

RESUMO

The aim of this study was to perform a physicochemical and morphological characterization and compare the mechanical behavior of an experimental Ti-Mo alloy to the analogous metallic Ti-based fixation system, for mandibular angle fractures. Twenty-eight polyurethane mandibles were uniformly sectioned on the left angle. These were divided into 4 groups: group Eng 1P, one 2.0-mm plate and 4 screws 6 mm long; group Eng 2P, two 2.0-mm plates, the first fixed with 4 screws 6 mm long and the second with 4 screws 12 mm long. The same groups were created for the Ti-15Mo alloy. Each group was subjected to linear vertical loading at the first molar on the plated side in a mechanical testing unit. Means and standard deviations were compared with respect to statistical significance using ANOVA. The chemical composition of the Ti-15Mo alloy was close to the nominal value. The mapping of Mo and Ti showed a homogeneous distribution. SEM of the screw revealed machining debris. For the plates, only the cpTi plate undergoes a surface treatment. The metallographic analysis reveals granular microstructure, from the thermomechanical trials. A statistically significant difference was found (P < 0.05) when the comparison between both internal fixation techniques was performed. The 2P technique showed better mechanical behavior than 1P.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Fraturas Mandibulares/cirurgia , Modelos Anatômicos , Poliuretanos/química , Ligas/química , Fenômenos Biomecânicos , Parafusos Ósseos , Análise do Estresse Dentário/instrumentação , Desenho de Equipamento , Humanos , Ácido Fluorídrico/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Ácido Nítrico/química , Espectrometria por Raios X , Estresse Mecânico , Propriedades de Superfície , Titânio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA