Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.293
Filtrar
1.
Surg Endosc ; 38(10): 6111-6119, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39266757

RESUMO

BACKGROUND: Since the introduction of powered circular staplers in colorectal surgery, there has been growing interest in their impact on reducing complications, particularly anastomotic leakage. This study compared short-term postoperative outcomes between powered and manual circular staplers. METHODS: This retrospective study included colorectal cancer patients at the tertiary referral center from April to October 2023 who underwent anterior or low anterior resection (LAR) using a circular stapler. According to energy source, patients were divided into powered and manual groups, which used two powered and four types of manual staplers, respectively. All open, laparoscopic, and robotic approaches were included. Propensity score matching (PSM) analysis was used to reduce selection bias. Postoperative complications within 30 days, especially for anastomosis-related complications, were compared between the groups. RESULTS: Among 511 patients, the powered group was 161 (32%). After PSM, 143 pairs of 286 patients were analyzed. The proportions of LAR were 53.8% and 51.0%, and initial diverting stoma rates were 23.1% and 22.4% for the Powered and Manual groups, respectively. Comprehensive complication rates were similar between the Powered group and the Manual group, without statistical significance (13.3% vs. 21.0%, P = 0.063). Anastomotic leakage was not different between the Powered and Manual groups (4.2% vs. 4.9%, P = 0.782). There was no significant difference in other complications, including anastomotic bleeding, ileus, surgical site infection, and intra-abdominal hematoma. CONCLUSIONS: The study implies that powered circular staplers may not significantly reduce postoperative complications, including anastomotic leakages, compared to manual staplers in colorectal surgery of high-volume centers.


Assuntos
Fístula Anastomótica , Neoplasias Colorretais , Grampeadores Cirúrgicos , Humanos , Fístula Anastomótica/prevenção & controle , Fístula Anastomótica/epidemiologia , Fístula Anastomótica/etiologia , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Neoplasias Colorretais/cirurgia , Idoso , Anastomose Cirúrgica/métodos , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/instrumentação , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/instrumentação , Laparoscopia/métodos , Laparoscopia/efeitos adversos
2.
Braz J Cardiovasc Surg ; 39(5): e20230479, 2024 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-39241214

RESUMO

INTRODUCTION: The operating room is no longer the ideal place for early surgica training of cardiothoracic surgery residents, forcing the search for simulation-based learning options. The study's aim was the construction and surgicaltraining of coronary anastomosis in a portable, low-cost, homemade simulator. METHODS: This is an observational, analytical, and multicenter study. The simulator was built with common materials and was evaluated with the Objective Structured Assessment ofTechnical Skills (or OSATS) Modified. All junior and senior residents from nine national cardiothoracic surgery centers were considered for 90 days. Operative skill acquisition and time in the creation of side-to-side (S-T-S), end-to-side (E-T-S), and end-to-end (E-T-E) coronary anastomoses were evaluated. All sessions were recorded and evaluated by a single senior cardiothoracic surgeon during two time periods. RESULTS: One hundred and forty residents were assessed in 270 sessions. In junior residents, a significant improvement in final scores was identified in S-T-S (use of Castroviejo needle holder, needle angles, and needle transfer) (P<0.05). In seniors, a significant improvement was identified in S-T-S (graft orientation, appropriate spacing, use of forceps, angles, and needle transfer) anastomoses (P<0.05). A significant improvement in the final anastomosis time of senior residents over junior residents was identified in S-T-S (8.11 vs. 11.22 minutes), E-T-S (7.93 vs. 10.10 minutes), and E-T-E (6.56 vs. 9.68 minutes) (P=0.039). CONCLUSION: Our portable and low-cost coronary anastomosis simulator is effective in improving operative skills in cardiothoracic surgery residents; therefore, skills acquired through simulation-based training transfer have a positive impact on the surgical environment.


Assuntos
Anastomose Cirúrgica , Competência Clínica , Internato e Residência , Treinamento por Simulação , Humanos , Treinamento por Simulação/economia , Anastomose Cirúrgica/educação , Anastomose Cirúrgica/instrumentação , Peru , Vasos Coronários/cirurgia , Reprodutibilidade dos Testes
3.
Asian J Endosc Surg ; 17(4): e13379, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39168481

RESUMO

The Senhance® robotic system (Senhance [Asensus Surgical Inc., Naderhan, NC, USA]) is a new surgical assistive robot following the da Vinci Surgical System that has been demonstrated to be safe and efficacious. Herein, we report the first case series of pediatric pelvic surgery using Senhance. Two anorectoplasties and one rectal pull-through coloanal anastomosis for rectal stenosis were performed in three children (5-9 months, 7-9 kg) using a 10-mm three-dimensional (3D) 4K camera and 3 and 5 mm forceps operated with Senhance. None of the patients had intraoperative complications or a good postoperative course. Pediatric pelvic surgery with Senhance could be performed precisely and safely with a small body cavity. With its beautiful 3D images, motion of forceps with reduced tremor, and availability of 3-mm forceps, Senhance may be better suited for children compared with other models.


Assuntos
Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/instrumentação , Lactente , Feminino , Masculino , Reto/cirurgia , Anastomose Cirúrgica/instrumentação , Constrição Patológica/cirurgia , Canal Anal/cirurgia , Doenças Retais/cirurgia
5.
J Robot Surg ; 18(1): 290, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39039393

RESUMO

Although circular staplers offer technical advancements over traditional hand-sewn techniques, their use remains challenging for unskilled users, necessitating substantial time and experience for mastery. In particular, it is challenging to apply a consistent pressure of an appropriate magnitude. We developed an automated circular anastomosis device using artificial intelligence (AI) to solve this problem. Automation through AI reduces experiential factors during the anastomosis process. We defined damage occurring during the anastomosis process, noting that a greater depth of damage indicated a more severe injury. For automated anastomosis, data at a tissue strain of 40% were used for the AI model, as this strain level showed optimal performance based on the accuracy and cost matrix. We compared the outcomes of automated anastomosis using a trained AI with those of unskilled users. The results were validated using the Shapiro-Wilk test and t tests. Compression damage was verified on collagen sheets. The AI-driven automatic compression system resulted in less damage compared to unskilled users. In particular, a more significant difference in damage was observed in poor-condition collagen than in good-condition collagen. Damage to the collagen under poor conditions was 54.8% when handled by unskilled users, while the AI-driven automatic compression system resulted in 38.9% damage. This study confirmed that novices' use of AI for automated anastomosis reduces the risk of damage, especially for tissues in poor condition.


Assuntos
Anastomose Cirúrgica , Inteligência Artificial , Colo , Procedimentos Cirúrgicos Robóticos , Anastomose Cirúrgica/métodos , Anastomose Cirúrgica/instrumentação , Humanos , Colo/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Reto/cirurgia , Automação , Pressão
6.
Colorectal Dis ; 26(6): 1271-1284, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38750621

RESUMO

AIM: Although proximal faecal diversion is standard of care to protect patients with high-risk colorectal anastomoses against septic complications of anastomotic leakage, it is associated with significant morbidity. The Colovac device (CD) is an intraluminal bypass device intended to avoid stoma creation in patients undergoing low anterior resection. A preliminary study (SAFE-1) completed in three European centres demonstrated 100% protection of colorectal anastomoses in 15 patients, as evidenced by the absence of faeces below the CD. This phase III trial (SAFE-2) aims to evaluate the safety and effectiveness of the CD in a larger cohort of patients undergoing curative rectal cancer resection. METHODS: SAFE-2 is a pivotal, multicentre, prospective, open-label, randomized, controlled trial. Patients will be randomized in a 1:1 ratio to either the CD arm or the diverting loop ileostomy arm, with a recruitment target of 342 patients. The co-primary endpoints are the occurrence of major postoperative complications within 12 months of index surgery and the effectiveness of the CD in reducing stoma creation rates. Data regarding quality of life and patient's acceptance and tolerance of the device will be collected. DISCUSSION: SAFE-2 is a multicentre randomized, control trial assessing the efficacy and the safety of the CD in protecting low colorectal anastomoses created during oncological resection relative to standard diverting loop ileostomy. TRIAL REGISTRATION: NCT05010850.


Assuntos
Anastomose Cirúrgica , Fístula Anastomótica , Colo , Neoplasias Retais , Reto , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anastomose Cirúrgica/instrumentação , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/métodos , Fístula Anastomótica/prevenção & controle , Colo/cirurgia , Ileostomia/instrumentação , Ileostomia/efeitos adversos , Ileostomia/métodos , Complicações Pós-Operatórias/prevenção & controle , Protectomia/efeitos adversos , Protectomia/métodos , Protectomia/instrumentação , Estudos Prospectivos , Qualidade de Vida , Neoplasias Retais/cirurgia , Reto/cirurgia , Resultado do Tratamento
8.
J Stomatol Oral Maxillofac Surg ; 125(3S): 101845, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38575496

RESUMO

PURPOSE: The aim of this study is to compare the outcomes of vascular anastomosis using loupes magnification versus operative microscope magnification in reconstructive surgery. METHODS: We performed a systematic review of MEDLINE (via PubMed), Scopus and Cochrane Library database according to the PRISMA guidelines. Comparative studies between the two techniques and single arm studies reporting on loupes reconstruction were included. Random-effects model meta-analyses were performed. RESULTS: Twelve studies, reporting a total of 3908 of flaps, 3409 of which were performed under loupes magnification and 499 under the operative microscope magnification were selected for analysis. No statistically significant differences were observed regarding total flap loss and vascular complication between the two arms. In the Loupes group the rate of total flap loss was 2.65% (95% CI: 1.15-4.63) and the rate of vascular complications 4.49% (95% CI: 2.58-6.84). CONCLUSION: Loupes magnification under circumstances can provide a safe and effective alternative to microvascular reconstruction in reconstructive surgery. With respect to flap failure and vascular complication rates, there appear to be no statistically significant differences between the anastomoses conducted under Loupes magnification and the standard operative microscope.


Assuntos
Anastomose Cirúrgica , Microscopia , Procedimentos de Cirurgia Plástica , Humanos , Anastomose Cirúrgica/métodos , Anastomose Cirúrgica/instrumentação , Procedimentos de Cirurgia Plástica/métodos , Procedimentos de Cirurgia Plástica/instrumentação , Procedimentos de Cirurgia Plástica/efeitos adversos , Microscopia/métodos , Microscopia/instrumentação , Microcirurgia/métodos , Microcirurgia/instrumentação , Procedimentos Cirúrgicos Vasculares/métodos , Procedimentos Cirúrgicos Vasculares/instrumentação , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Retalhos Cirúrgicos
9.
J Craniomaxillofac Surg ; 52(6): 704-706, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38627187

RESUMO

Many surgical fields profit from robotic support devices. After the first case reports about the use of a special microsurgical roboter (Symani Sugrical System, Medical Microinstruments, Pisa, Italy) we evaluated the potential of such a device in cranio- and maxillofacial surgery in a world's first single-center case series. This novel piece of equipment is meant to assist the surgeon anastomosing small vessels, nerves and lymphatic vessels. In total 30 free flaps were performed and compared to another 30 conventionally anastomosed free flaps. In total 127 anastomoses were surveyed. We encountered a lot of potential for robotic supported operations in the field of cranio- and maxillofacial surgery. However, the surgery time for robotic supported anastomosis with an average time of 32.5 min to perform arterial anastomosis was significant longer than the conventional ones, which needed 11.8 min on average. Tremor Filter and Motion Scaling are promising features for future microsurgery but the grip of the microinstruments has to be improved. It remains to be seen if the potential will be validated after the upcoming learning period and if robotic support devices will prevail in cranio- and maxillofacial surgery.


Assuntos
Anastomose Cirúrgica , Retalhos de Tecido Biológico , Microcirurgia , Procedimentos Cirúrgicos Robóticos , Humanos , Microcirurgia/instrumentação , Anastomose Cirúrgica/instrumentação , Procedimentos Cirúrgicos Robóticos/instrumentação , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Duração da Cirurgia , Idoso , Procedimentos de Cirurgia Plástica/instrumentação , Procedimentos de Cirurgia Plástica/métodos , Robótica/instrumentação
10.
Colorectal Dis ; 26(4): 754-759, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38443753

RESUMO

AIM: Creation of an overlapped anastomosis using handsewn sutures for common enterotomy is very popular in robotic right colectomy (RRC) with intracorpareal anastomosis (IA). The aim of this study is to present a simple method for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in RRC with IA. METHOD: The distal ileum and proximal colon were put in overlapping positions. Enterotomies were created 2 cm proximal to the ileal stump and 8 cm distal to the colonic stump on the antimesenteric side. Subsequently, a 60 mm linear stapler with a reinforced bioabsorbable material was inserted into each lumen and fired. Finally, the bowel was elevated while holding the bioabsorbable material, and the common enterotomy was grasped with the robotic instrument in the middle and closed using a linear stapler with a reinforced bioabsorbable material. RESULTS: This technique was applied to 10 patients with tumours of the caecum, ascending colon, or transverse colon. The median operating time, anastomosis construction time, blood loss, and postoperative stay were 281 min (range 228-459 min), 12 min (range 11-17 min), 10 mL (range 0-110 mL), and 10 days (range 8-15 days), respectively. No adverse intraoperative events were observed. Postoperatively, one patient developed chylous ascites, but there were no other complications. CONCLUSION: The simple technique for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis appears to be safe and feasible.


Assuntos
Implantes Absorvíveis , Anastomose Cirúrgica , Colectomia , Neoplasias do Colo , Íleo , Procedimentos Cirúrgicos Robóticos , Grampeadores Cirúrgicos , Colectomia/métodos , Colectomia/instrumentação , Humanos , Anastomose Cirúrgica/métodos , Anastomose Cirúrgica/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Neoplasias do Colo/cirurgia , Íleo/cirurgia , Procedimentos Cirúrgicos sem Sutura/métodos , Procedimentos Cirúrgicos sem Sutura/instrumentação , Duração da Cirurgia , Colo/cirurgia , Resultado do Tratamento , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/instrumentação , Adulto , Tempo de Internação
11.
Am J Otolaryngol ; 45(4): 104262, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38552339

RESUMO

OBJECTIVE: In light of the recent US Food and Drug Administration (FDA) Class 2 safety recall notice for anastomotic coupling devices, it is important to understand related adverse events. The aim of this study was to characterize adverse events in anastomotic coupling devices for microvascular reconstruction. METHODS: A retrospective cross-sectional analysis using the 2011 to 2021 US FDA Manufacturer and User Facility Device Experience (MAUDE) database. All reports of adverse events involving anastomotic coupling devices were retrieved from the MAUDE database. Descriptive statistics were used to analyze categorized events. RESULTS: There were a total of 293 documented adverse events related to anastomotic coupling devices. These adverse events resulted in 91 (31.1 %) patient injuries and 239 (81.6 %) device malfunctions. The most frequent patient problems were thrombosis/hematoma (n = 38; 41.8 %), unspecified injury (n = 31; 34.1 %), and failure to anastomose (n = 13; 14.3 %). Free flap necrosis was reported in 42 % of thrombosis/hematoma cases (n = 16). The most common malfunctions were devices operating differently than expected (n = 74; 31.0 %), connection problems (n = 41; 17.2 %), and twisted/bent material (n = 19; 7.9 %). There was no significant trend in the number of adverse events over the study period (p > 0.05). CONCLUSIONS: Adverse events from anastomotic coupling devices represent an important and modifiable factor in free tissue failure. Adverse events are predominately related to devices operating differently than expected and may result in vascular compromise of the free flap. Reconstructive surgeons should be cognizant of defective anastomotic coupling devices and be prepared to utilize traditional hand-sewn anastomosis.


Assuntos
Anastomose Cirúrgica , Microcirurgia , Procedimentos de Cirurgia Plástica , Humanos , Estudos Retrospectivos , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/instrumentação , Estudos Transversais , Procedimentos de Cirurgia Plástica/instrumentação , Procedimentos de Cirurgia Plástica/efeitos adversos , Procedimentos de Cirurgia Plástica/métodos , Microcirurgia/instrumentação , Microcirurgia/efeitos adversos , Falha de Equipamento/estatística & dados numéricos , Estados Unidos , Trombose/etiologia , United States Food and Drug Administration , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Retalhos de Tecido Biológico/efeitos adversos , Bases de Dados Factuais
12.
Colorectal Dis ; 26(4): 766-771, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38302860

RESUMO

AIM: Natural orifice specimen extraction (NOSE) in left-sided colorectal surgery requires application of the circular stapler anvil to the proximal bowel without exteriorization through an additional abdominal incision. We describe an intracorporeal method to secure the stapler anvil, termed the intracorporeal antimesenteric ancillary trocar (IAAT) technique. METHOD: The ancillary trocar is attached to the stapler anvil before introduction into the abdominal cavity through the anal or vaginal orifice. The colon is incised before the trocar spike is brought out through the antimesenteric surface 3-4 cm within the cut edge. A linear stapler is used to seal the bowel end. The ancillary trocar is detached and retrieved via the NOSE conduit. Following the NOSE procedure, a side-to-end colorectal anastomosis is performed with the transanal circular stapler. RESULTS: Ten consecutive patients underwent elective left-sided colorectal resection with IAAT for NOSE (seven transanal, three transvaginal) from January to June 2023. Median age and body mass index were 66 (range 47-74) years and 24.3 (range 17.9-30.8) kg/m2 respectively. Two (20%) patients underwent sigmoid colectomy for sigmoid volvulus while eight (80%) underwent anterior resection for colorectal cancer. Median operating time, operative blood loss and postoperative length of hospital stay were 170 (range 140-240) min, 20 (range 10-40) mL and 1 (range 1-3) day respectively. There were no postoperative complications, readmissions or reoperations. Median follow-up duration was 3 (range 1-6) months. CONCLUSION: The IAAT double-stapling side-to-end anastomotic technique is safe and feasible for patients undergoing left-sided colorectal resection with NOSE, resulting in good outcomes.


Assuntos
Anastomose Cirúrgica , Colectomia , Cirurgia Endoscópica por Orifício Natural , Humanos , Feminino , Pessoa de Meia-Idade , Anastomose Cirúrgica/métodos , Anastomose Cirúrgica/instrumentação , Idoso , Masculino , Cirurgia Endoscópica por Orifício Natural/métodos , Cirurgia Endoscópica por Orifício Natural/instrumentação , Colectomia/métodos , Colectomia/instrumentação , Colo/cirurgia , Instrumentos Cirúrgicos , Vagina/cirurgia , Grampeadores Cirúrgicos , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/instrumentação , Reto/cirurgia , Duração da Cirurgia
13.
J Surg Res ; 276: 283-290, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35405414

RESUMO

INTRODUCTION: The magnetic compression technique (MCT) is used for the anastomosis of hollow organs by the means of suction between magnets. The MCT is useful for establishing digestive tract anastomoses in rats, for example, end-to-side small intestinal anastomosis and colonic anastomosis. We aim to determine the feasibility of MCT-based esophageal anastomosis in rats. METHODS: Twenty-four Sprague-Dawley albino rats (230-250 g) were randomly divided into an MCT group and a control group (hand-sewn esophageal anastomosis). The time required to construct the anastomosis, postoperative complications, and survival rate was compared between the two groups. At 2 wk postoperatively, the animals were sacrificed to assess the burst pressure and histological features of the anastomoses. RESULTS: The mean anastomosis time was significantly lower for MCT (11.17 ± 1.64 min) than for the hand-sewn technique (27.42 ± 2.23 min; P < 0.001). The survival rate was slightly higher in the MCT group (91.67%) than in the control group (66.67%, P = 0.317). The magnets were discharged from the body after 8.33 ± 0.89 d (range, 7-10 d). No anastomotic leakage or stenosis occurred in the MCT group. Three rats developed anastomotic stenosis and two rats developed anastomotic leakage in the control group. The burst pressures were similar in the two groups. An histological examination showed that compared with the control group, the MCT group had better alignment of the tissue layers and less inflammation. CONCLUSIONS: The MCT is a simple and feasible technique for esophageal anastomosis in rats and has the potential for clinical application.


Assuntos
Anastomose Cirúrgica , Procedimentos Cirúrgicos do Sistema Digestório , Esôfago , Imãs , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/instrumentação , Anastomose Cirúrgica/métodos , Fístula Anastomótica/etiologia , Fístula Anastomótica/prevenção & controle , Animais , Constrição Patológica/etiologia , Procedimentos Cirúrgicos do Sistema Digestório/efeitos adversos , Procedimentos Cirúrgicos do Sistema Digestório/instrumentação , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Esôfago/cirurgia , Fenômenos Magnéticos , Ratos , Ratos Sprague-Dawley , Técnicas de Sutura
14.
Sci Robot ; 7(62): eabj2908, 2022 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-35080901

RESUMO

Autonomous robotic surgery has the potential to provide efficacy, safety, and consistency independent of individual surgeon's skill and experience. Autonomous anastomosis is a challenging soft-tissue surgery task because it requires intricate imaging, tissue tracking, and surgical planning techniques, as well as a precise execution via highly adaptable control strategies often in unstructured and deformable environments. In the laparoscopic setting, such surgeries are even more challenging because of the need for high maneuverability and repeatability under motion and vision constraints. Here we describe an enhanced autonomous strategy for laparoscopic soft tissue surgery and demonstrate robotic laparoscopic small bowel anastomosis in phantom and in vivo intestinal tissues. This enhanced autonomous strategy allows the operator to select among autonomously generated surgical plans and the robot executes a wide range of tasks independently. We then use our enhanced autonomous strategy to perform in vivo autonomous robotic laparoscopic surgery for intestinal anastomosis on porcine models over a 1-week survival period. We compared the anastomosis quality criteria-including needle placement corrections, suture spacing, suture bite size, completion time, lumen patency, and leak pressure-of the developed autonomous system, manual laparoscopic surgery, and robot-assisted surgery (RAS). Data from a phantom model indicate that our system outperforms expert surgeons' manual technique and RAS technique in terms of consistency and accuracy. This was also replicated in the in vivo model. These results demonstrate that surgical robots exhibiting high levels of autonomy have the potential to improve consistency, patient outcomes, and access to a standard surgical technique.


Assuntos
Anastomose Cirúrgica/métodos , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Algoritmos , Anastomose Cirúrgica/instrumentação , Anastomose Cirúrgica/estatística & dados numéricos , Animais , Procedimentos Cirúrgicos do Sistema Digestório/instrumentação , Procedimentos Cirúrgicos do Sistema Digestório/estatística & dados numéricos , Humanos , Intestino Delgado/cirurgia , Laparoscopia/instrumentação , Laparoscopia/métodos , Laparoscopia/estatística & dados numéricos , Aprendizado de Máquina , Movimento (Física) , Imagens de Fantasmas , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/estatística & dados numéricos , Técnicas de Sutura , Suínos
15.
J Hepatobiliary Pancreat Sci ; 29(7): 817-824, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35030302

RESUMO

BACKGROUND/PURPOSE: Although the lumen-apposing metal stent (LAMS) is useful for interventional endoscopic ultrasound (EUS) procedures, there has been some concern about the potential for stent-induced adverse events because of the high lumen-apposing force. A newly designed LAMS with less lumen-apposing force has been developed for use with a physician-controlled electrocautery-enhanced delivery system. The aim of this animal study was to evaluate the feasibility of performing interventional EUS using this newly designed LAMS system. METHODS: Endoscopic ultrasound-guided cystogastrostomy was performed using the novel LAMS three times in a wet simulation model. EUS-guided gastroenterostomy and EUS-guided gallbladder drainage were then performed using the system in four pigs. RESULTS: The LAMS was successfully placed in all three EUS-guided cystogastrostomy procedures using the wet simulation model and in all four EUS-guided gastroenterostomy and gallbladder drainage procedures in the animal model. In the 3 weeks following the procedure, eating behavior was normal in all animals and there were no adverse events. The stents remained patent during this time and were removed without difficulty. The fistula was mature in all cases and a standard upper gastrointestinal endoscope was easily advanced via the fistula to observe the afferent and efferent loops or the lumen of the gallbladder. Necropsy confirmed complete adhesion between the stomach and the wall of the jejunum or gallbladder. CONCLUSIONS: Our study findings demonstrate the feasibility of this new LAMS system and its potential clinical value for interventional EUS.


Assuntos
Anastomose Cirúrgica , Eletrocoagulação , Endossonografia , Implantação de Prótese , Stents , Ultrassonografia de Intervenção , Anastomose Cirúrgica/instrumentação , Anastomose Cirúrgica/métodos , Animais , Fístula do Sistema Digestório/etiologia , Fístula do Sistema Digestório/cirurgia , Drenagem/instrumentação , Drenagem/métodos , Eletrocoagulação/instrumentação , Eletrocoagulação/métodos , Endossonografia/instrumentação , Endossonografia/métodos , Vesícula Biliar/cirurgia , Jejuno/cirurgia , Modelos Animais , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos , Estômago/cirurgia , Suínos , Ultrassonografia de Intervenção/instrumentação , Ultrassonografia de Intervenção/métodos
16.
Dis Colon Rectum ; 65(2): 246-253, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34657080

RESUMO

BACKGROUND: The International Transanal Total Mesorectal Excision Registry group showed that transanal total mesorectal excision included clinical issues regarding anastomosis-related complications. OBJECTIVE: This study evaluated anastomotic complications in patients whose anastomoses were created with the stapler plus reinforced sutures procedure after transanal total mesorectal excision for low rectal cancer. DESIGN: This was a retrospective single-center study. SETTING: The study was conducted at the National Cancer Center Hospital East, Japan. PATIENTS: Between June 2016 and December 2019, 150 patients underwent transanal total mesorectal excision for low rectal cancer. Stapled anastomosis was performed for 55 patients, and coloanal handsewn anastomosis was performed for 95 patients. Blood perfusion of the colon was routinely evaluated with intraoperative indocyanine green fluorescence angiography. All patients who underwent stapled anastomosis received additional handsewn sutures on all rounds of the stapled line. Patients who underwent intersphincteric resection were excluded. MAIN OUTCOME MEASURES: The anastomosis-related complications were compared between the groups. RESULTS: Early anastomotic leakage was found in one (1.8%) and eight (8.4%) patients in the stapled group and handsewn group. Overall anastomosis-related complications, pelvic abscess, and anastomotic stenosis were significantly less frequent in the stapled group (p < 0.001, p < 0.048, and p < 0.032). Incomplete donuts after the stapled anastomosis were observed in 9 patients (16.4%); however, we reinforced all around the stapled line in these patients, and this reduced the subsequent occurrence of anastomotic leakage. LIMITATIONS: First, this was a retrospective single-center study that was not randomized or controlled. Second, there were chronological differences regarding the anastomotic method between the two groups. Third, our study included a relatively small number of patients who received preoperative chemoradiotherapy. CONCLUSIONS: Stapled anastomosis with reinforced handsewn sutures resulted in fewer anastomosis-related complications than did coloanal handsewn anastomosis after transanal total mesorectal excision for low rectal cancer; thus, the former may be superior and should be the preferred method, when technically possible. See Video Abstract at http://links.lww.com/DCR/B749.COMPLICACIONES RELACIONADAS CON LAS ANASTOMOSIS ENGRAMPADAS Y REFORZADAS CON SUTURAS EN LA EXCISIÓN TOTAL DEL MESORRECTO POR VÍA TRANSANAL EN CASOS DE CÁNCER DE RECTO BAJO: ESTUDIO RETROSPECTIVO UNICÉNTRICO. ANTECEDENTES: El grupo del Registro Internacional de Excisión Total del Mesorrecto por vía Transanal mostró que la excisión total mesorrectal transanal incluía problemas clínicos relacionados a las complicaciones involucradas con la anastomosis. OBJETIVO: Se evaluaron las complicaciones anastomóticas en pacientes cuyas anastomosis se realizaron con engrampadora reforzada de suturas después de la excisión total de l mesorrecto por vía transanal en casos de cáncer de recto bajo. DISEO: Estudio retrospectivo unicéntrico. AJUSTE: El Hospital del Centro Nacional del Cáncer del Este, Japón. PACIENTES: Entre junio de 2016 y diciembre de 2019, 150 pacientes se sometieron a excisión total del mesorrecto por vía transanal en casos de cáncer de recto bajo. Se realizó anastomosis con engrampadora en 55 y anastomosis coloanal suturada a mano en 95 pacientes. La perfusión tisular sanguínea del colon operado se evaluó de forma rutinaria con angiografía de fluorescencia con verde de indocianina intraoperatoria. Todos los pacientes que se sometieron a anastomosis con grapas recibieron suturas realizadas a mano adicionales sobre la totalidad de la línea de grapas. Se excluyeron los pacientes sometidos a resección interesfintérica. PRINCIPALES MEDIDAS DE RESULTADO: Las complicaciones relacionadas con la anastomosis se compararon entre los grupos. RESULTADOS: Se encontró fuga anastomótica temprana en 1 (1.8%) y 8 (8.4%) pacientes en el grupo de engrampado y en el grupo suturado a mano, respectivamente. En general, las complicaciones relacionadas con la anastomosis, el absceso pélvico y la estenosis anastomótica fueron significativamente menos frecuentes en el grupo con grapas (p < 0.001, p < 0.048, p < 0.032, respectivamente). Se observaron donas incompletas después de la anastomosis grapada en 9 pacientes (16,4%); sin embargo, reforzamos todo alrededor de la línea de grapas en estos pacientes, y esto redujo la aparición posterior de fugas anastomóticas. LIMITACIONES: Inicialmente, este fue un estudio retrospectivo de un solo centro que no fue aleatorizado ni controlado. En segundo lugar, hubo diferencias cronológicas con respecto al método anastomótico entre los dos grupos. En tercer lugar, nuestro estudio incluyó un número relativamente pequeño de pacientes que recibieron quimiorradioterapia preoperatoria. CONCLUSIONES: La anastomosis engrapada reforzada con suturas realizadas a mano dio como resultado menos complicaciones relacionadas con la anastomosis que la anastomosis coloanal suturada a mano después de la excisión total del mesorrecto por vía transanal en casos de cáncer de recto bajo; por tanto, el primero puede ser superior y debería ser el método preferido, cuando sea técnicamente posible. Consulte Video Resumen en http://links.lww.com/DCR/B749. (Traducción-Dr. Xavier Delgadillo).


Assuntos
Anastomose Cirúrgica/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Protectomia/efeitos adversos , Neoplasias Retais/cirurgia , Grampeamento Cirúrgico/efeitos adversos , Suturas/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Anastomose Cirúrgica/instrumentação , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Neoplasias Retais/patologia , Estudos Retrospectivos , Grampeamento Cirúrgico/instrumentação
17.
Sci Rep ; 11(1): 21857, 2021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34750473

RESUMO

Prevention of postoperative anastomotic leakage in rectal surgery is still required. This study investigated the feasibility of endoscopic hand suturing (EHS) on rectal anastomosis ex vivo. By using isolated porcine colon, we prepared ten anastomoses 6-10 cm from the virtual anus. Then, we sutured anastomoses intraluminally by EHS, which involved a continuous suturing method in 5 cases and a nodule suturing method with extra corporeal ligation in 5 cases. Completeness of suturing, number of stitches, procedure time and presence of stenosis were investigated. Furthermore, the degree of stenosis was compared between the two suturing methods. In all cases, EHS were successfully completed. The median number of stitches and procedure time was 8 and 5.8 min, respectively. Stenosis was created in all continuous suturing cases whereas none was seen in nodule suturing cases. The shortening rate was significantly greater in the continuous suturing method than in the nodule suturing method. Intraluminal reinforcement of rectal anastomosis by EHS using nodule suturing with extra corporeal ligation is feasible without stenosis, which may be helpful as a countermeasure against possible postoperative anastomotic leakage in rectal surgery.


Assuntos
Anastomose Cirúrgica/métodos , Fístula Anastomótica/prevenção & controle , Modelos Anatômicos , Reto/cirurgia , Técnicas de Sutura , Anastomose Cirúrgica/instrumentação , Animais , Endoscopia Gastrointestinal/instrumentação , Endoscopia Gastrointestinal/métodos , Estudos de Viabilidade , Humanos , Técnicas In Vitro , Modelos Animais , Proctoscopia/instrumentação , Proctoscopia/métodos , Sus scrofa , Técnicas de Sutura/instrumentação
18.
Pediatrics ; 148(5)2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34615695

RESUMO

Thoracoscopic esophageal atresia (EA) repair affords many benefits to the patient; however, intracorporeal suturing of the anastomosis is technically challenging. Esophageal magnetic compression anastomosis (EMCA) is a compelling option for endoluminal EA repair, but available EMCA devices have prohibitive rates of recalcitrant stricture. Connect-EA is a new endoluminal EMCA device system that employs 2 magnetic anchors with a unique mating geometry designed to reliably create a robust anastomosis and decrease rates of leak and stricture. We describe our first-in-human experience with this novel endoluminal device for staged EA repair in 3 patients (Gross type A, B, and C) at high risk for conventional surgical repair. First, the esophageal pouches were approximated thoracoscopically. After acute tension subsided, the device anchors were endoscopically placed in the esophageal pouches and mated. Anchors were spontaneously excreted in 2 cases. Endoscopic repositioning and retrieval of the anchors were required in 1 patient because of narrowed esophageal anatomy. There were no perioperative complications. Patients were managed for 14 to 18 months. The strictures that developed in the patients were membranous and responded well to dilation alone, resolving after 4 to 5 outpatient dilations. Gastrostomies were closed between 6 and 11 months and all patients are tolerating full oral nutrition. Early experience with this new endoluminal EMCA device system is highly favorable. The device offers considerable benefit over conventional handsewn esophageal anastomosis and anastomotic outcomes are superior to available EMCA devices.


Assuntos
Anastomose Cirúrgica/instrumentação , Atresia Esofágica/cirurgia , Imãs , Anastomose Cirúrgica/métodos , Fístula Anastomótica/prevenção & controle , Dilatação/métodos , Desenho de Equipamento , Estenose Esofágica/prevenção & controle , Esofagoscopia , Idade Gestacional , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Toracoscopia/métodos , Resultado do Tratamento
20.
World Neurosurg ; 156: 53-55, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34508907

RESUMO

OBJECTIVE: The standard way of isolating bypass vessels from surrounding structures during cerebral bypass surgery has been to use a rubber dam or neurosurgical patty. Here, the use of polyvinyl alcohol (PVA) sponges is described as a possible upgrade from these traditional bypass dams. METHODS: PVA sponges were used to isolate bypass arteries from surrounding tissues during microvascular anastomosis in 25 patients undergoing bypass surgery at our institution. RESULTS: There were no adverse events related to the use of PVA for microvascular anastomosis. PVA sponges offered some specific advantages when compared with rubber and cottonoid dams. CONCLUSIONS: Although preliminary, our experience using PVA sponges during microvascular anastomosis suggests some of their properties can facilitate cerebral bypass surgery.


Assuntos
Revascularização Cerebral/métodos , Álcool de Polivinil/administração & dosagem , Tampões de Gaze Cirúrgicos , Anastomose Cirúrgica/instrumentação , Anastomose Cirúrgica/métodos , Revascularização Cerebral/instrumentação , Humanos , Álcool de Polivinil/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA