Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.066
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Cardiovasc Surg (Torino) ; 65(2): 119-123, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38618696

RESUMO

This article summarizes the key findings in literature up to date on the endovascular treatment of complex abdominal aortic aneurysms (AAAs) employing the chimney technique. Additionally, an unexplored pitfall is described regarding the target vessel angulation. Although balloon-expandable covered stents present more favorable configuration in downward-oriented target vessels, transverse and upward-oriented target vessels may benefit from other endovascular techniques imploring careful case planning and further investigation on the topic.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Artéria Renal , Stents , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Humanos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Artéria Renal/cirurgia , Artéria Renal/diagnóstico por imagem , Resultado do Tratamento , Procedimentos Endovasculares/instrumentação , Desenho de Prótese , Fatores de Risco
2.
J Cardiovasc Surg (Torino) ; 65(2): 124-131, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38635285

RESUMO

INTRODUCTION: We performed a systematic review and meta-analysis to assess the existing published evidence regarding the safety and efficacy of the endovascular aortic repair with chimney technique (ch-EVAR) and physician-modified stent-grafts (PMSGs) for the treatment of pararenal aortic aneurysm repair. EVIDENCE ACQUISITION: A systematic search of all relevant studies reported until October 2023 according to the PRISMA (preferred reporting items for systematic reviews and meta-analyses) guidelines was performed. The pooled 30-day mortality, peri- and postoperative complication rates were estimated using fixed or random effect methods. EVIDENCE SYNTHESIS: A total of 679 study titles were identified by the initial search strategy, of which 16 were considered eligible for inclusion in the meta-analysis. A total of 1094 patients (ch-EVAR N.=861 and PMSG N.=233) (90% male) were identified. The pooled 30-day mortality rate was 3.4% for ch-EVAR and 2.6% for PMSG. The major adverse events (MAE) in the early period was 14.7% for ch-EVAR and 18.5% PMSG, respectively. Higher occlusion rate was observed of the chimney stents grafts (8.2%) than the bridging stents (1.4%) during the follow-up period. CONCLUSIONS: Ch-EVAR and physician-modified technology are safe with low 30-day mortality in elective settings for pararenal aortic aneurysms repair. No significant differences were seen between the two surgical methods regarding the early major adverse events rate. However, higher occlusion rate for the chimneys can be expected over time.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Complicações Pós-Operatórias , Desenho de Prótese , Stents , Humanos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Procedimentos Endovasculares/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Resultado do Tratamento , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Masculino , Feminino , Idoso , Fatores de Tempo , Medição de Risco , Pessoa de Meia-Idade
3.
J Cardiovasc Surg (Torino) ; 65(2): 110-118, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38635286

RESUMO

BACKGROUND: The aim of this study was to evaluate the anatomical feasibility of current available fenestrated endografts (FEVAR) and on-label chimney technique (EnChEVAR) in patients with complex abdominal aortic aneurysms (C-AAA). METHODS: Feasibility of EnChEVAR (Endurant II/IIS CE-marked [Medtronic]) and 4 types of FEVAR (Zenith Fenestrated CE-marked, Zenith Fenestrated Low-Profile [LP] custom-made device [CMD] [Cook Medical], Fenestrated Anaconda LoPro90 CMD, Fenestrated Treo CMD [Terumo Aortic]) was assessed according to the manufacturer's instructions for use. Computed tomography angiograms of patients with C-AAA previously included in the Protagoras 2.0 study were retrospectively reviewed. The aortic coverage was ideally planned to involve a maximum of two chimney grafts or fenestrations. RESULTS: Iliac access and aortic neck of 73 C-AAAs were analyzed. The overall feasibility was significantly different between EnChEVAR (33%) and FEVAR (Zenith Fenestrated 15%, Zenith Fenestrated LP 15%, Fenestrated Anaconda LoPro90 45%, Fenestrated Treo 48%). The iliac access feasibility was significantly lower for Zenith Fenestrated with standard profile compared to all other grafts. The aortic neck feasibility was significantly higher for EnChEVAR and both Terumo Aortic fenestrated stent grafts, compared to both Cook Medical grafts. The treatment using any of the three current available fenestrated grafts with lower profile (Zenith Fenestrated LP, Fenestrated Anaconda LoPro90, Fenestrated Treo) would have been feasible in 71% of the cases. CONCLUSIONS: Most of the patients treated by ChEVAR would have not been treated by first generation fenestrated stent graft. The current available fenestrated endografts, with lower profile and suitable also for angulated necks, increase the anatomical feasibility.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares , Estudos de Viabilidade , Desenho de Prótese , Stents , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Feminino , Masculino , Idoso , Resultado do Tratamento , Idoso de 80 Anos ou mais , Meios de Contraste , Aortografia
5.
J Cardiovasc Surg (Torino) ; 65(2): 106-109, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38635287

RESUMO

BACKGROUND: The aim of this study was to evaluate the early results of the CE-marked standardized device combination consisting of Endurant and the Radiant chimney graft (En-ChEVAR) for the treatment of juxtarenal aortic aneurysms. METHODS: We analyzed multicentric non-industry sponsored case series evaluating the EnChEVAR technique for patients treated between December 2022 and February 2024. Clinical, perioperative procedure-related and radiological data were collected. The primary outcome measure was the freedom of a type Ia gutter-related endoleak at postoperative computed tomography angiography (CTA). Secondary outcome measures included early type Ia endoleak-related reinterventions, target vessel complications including dissection or loss of target vessel, major adverse events, and mortality. Continuous variables were presented as median (interquartile range [IQR]) and categorical variables as count and percentage. RESULTS: Ten patients were included in the present study. Eight (80%) were males, in nine cases a single chimney was implanted, and the other one was a double chimney graft placement. The treated aneurysms had an infrarenal neck length of 3.4 (1.2) mm. The rate of main body oversizing was 30%. The new neck length after chimney graft placement was 18 (3) mm. The median procedural time was 130 (17) mm, contrast medium use was 109 (26) mL, radiation time was 45 (12) min. The technical success was 100%. No type Ia endoleak was detected at the postoperative CTA. There were no target vessel issues. No major adverse events or death were observed. CONCLUSIONS: First reported cohort of patients treated with EnChEVAR demonstrated reproducible clinical and procedural outcomes within the 3 vascular centers with total exclusion of the aneurysms, patent renal arteries, and no evidence of gutter-related type IA endoleak. Further evidence with larger sample size of treated patients and longer follow-up are needed.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Endoleak , Procedimentos Endovasculares , Desenho de Prótese , Sistema de Registros , Humanos , Masculino , Feminino , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Idoso , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Endoleak/etiologia , Fatores de Tempo , Resultado do Tratamento , Idoso de 80 Anos ou mais , Stents , Estudos Retrospectivos , Fatores de Risco , Rotulagem de Produtos , Correção Endovascular de Aneurisma
6.
Sci Rep ; 14(1): 8924, 2024 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637613

RESUMO

Accurate measurement of abdominal aortic aneurysm is essential for selecting suitable stent-grafts to avoid complications of endovascular aneurysm repair. However, the conventional image-based measurements are inaccurate and time-consuming. We introduce the automated workflow including semantic segmentation with active learning (AL) and measurement using an application programming interface of computer-aided design. 300 patients underwent CT scans, and semantic segmentation for aorta, thrombus, calcification, and vessels was performed in 60-300 cases with AL across five stages using UNETR, SwinUNETR, and nnU-Net consisted of 2D, 3D U-Net, 2D-3D U-Net ensemble, and cascaded 3D U-Net. 7 clinical landmarks were automatically measured for 96 patients. In AL stage 5, 3D U-Net achieved the highest dice similarity coefficient (DSC) with statistically significant differences (p < 0.01) except from the 2D-3D U-Net ensemble and cascade 3D U-Net. SwinUNETR excelled in 95% Hausdorff distance (HD95) with significant differences (p < 0.01) except from UNETR and 3D U-Net. DSC of aorta and calcification were saturated at stage 1 and 4, whereas thrombus and vessels were continuously improved at stage 5. The segmentation time between the manual and AL-corrected segmentation using the best model (3D U-Net) was reduced to 9.51 ± 1.02, 2.09 ± 1.06, 1.07 ± 1.10, and 1.07 ± 0.97 min for the aorta, thrombus, calcification, and vessels, respectively (p < 0.001). All measurement and tortuosity ratio measured - 1.71 ± 6.53 mm and - 0.15 ± 0.25. We developed an automated workflow with semantic segmentation and measurement, demonstrating its efficiency compared to conventional methods.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Calcinose , Procedimentos Endovasculares , Trombose , Humanos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aprendizagem Baseada em Problemas , Semântica , Tomografia Computadorizada por Raios X , Processamento de Imagem Assistida por Computador
8.
Langenbecks Arch Surg ; 409(1): 135, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38649506

RESUMO

OBJECTIVE: Endovascular repair is the preferred treatment for aortoiliac aneurysm, with preservation of at least one internal iliac artery recommended. This study aimed to assess pre-endovascular repair anatomical characteristics of aortoiliac aneurysm in patients from the Global Iliac Branch Study (GIBS, NCT05607277) to enhance selection criteria for iliac branch devices (IBD) and improve long-term outcomes. METHODS: Pre-treatment CT scans of 297 GIBS patients undergoing endovascular aneurysm repair were analyzed. Measurements included total iliac artery length, common iliac artery length, tortuosity index, common iliac artery splay angle, internal iliac artery stenosis, calcification score, and diameters in the device's landing zone. Statistical tests assessed differences in anatomical measurements and IBD-mediated internal iliac artery preservation. RESULTS: Left total iliac artery length was shorter than right (6.7 mm, P = .0019); right common iliac artery less tortuous (P = .0145). Males exhibited greater tortuosity in the left total iliac artery (P = .0475) and larger diameter in left internal iliac artery's landing zone (P = .0453). Preservation was more common on right (158 unilateral, 34 bilateral) than left (105 unilateral, 34 bilateral). There were 192 right-sided and 139 left-sided IBDs, with 318 IBDs in males and 13 in females. CONCLUSION: This study provides comprehensive pre-treatment iliac anatomy analysis in patients undergoing endovascular repair with IBDs, highlighting differences between sides and sexes. These findings could refine patient selection for IBD placement, potentially enhancing outcomes in aortoiliac aneurysm treatment. However, the limited number of females in the study underscores the need for further research to generalize findings across genders.


Assuntos
Procedimentos Endovasculares , Aneurisma Ilíaco , Humanos , Masculino , Feminino , Aneurisma Ilíaco/cirurgia , Aneurisma Ilíaco/diagnóstico por imagem , Idoso , Procedimentos Endovasculares/métodos , Pessoa de Meia-Idade , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/patologia , Artéria Ilíaca/diagnóstico por imagem , Implante de Prótese Vascular/métodos , Idoso de 80 Anos ou mais , Tomografia Computadorizada por Raios X , Resultado do Tratamento
9.
Medicine (Baltimore) ; 103(14): e37731, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38579061

RESUMO

RATIONALE: A hostile iliac access route is an important consideration when enforcing endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA). Herein, we report a case of AAA with unilateral external iliac artery occlusion, for which bifurcated EVAR was successfully performed using a single femoral and brachial artery access. PATIENT CONCERNS: A 76-year-old man who had undergone surgery for lung cancer 4.5 years prior was diagnosed AAA by computed tomography (CT). DIAGNOSIS: Two and a half years before presentation, CT revealed an infrarenal 48 mm AAA, which had enlarged to 57 mm by 2 months preoperatively. CT identified occlusion from the right external iliac artery to the right common femoral artery, with no observed ischemic symptoms in his right leg. The right external iliac artery, occluded and atrophied, had a 1 to 2 mm diameter. INTERVENTION: Surgery was commenced with the selection of a Zenith endovascular graft (Cook Medical) with an extended body length. Two Gore Viabahn VBX balloon expandable endoprosthesis (VBX; W.L. Gore & Associate) were delivered from the right axilla as the contralateral leg. OUTCOMES: CT scan on the 2nd day after surgery revealed no endoleaks. LESSONS: While the long-term results remain uncertain, this method may serve as an option for EVAR in patients with unilateral external iliac artery occlusion.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco , Masculino , Humanos , Idoso , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Implante de Prótese Vascular/métodos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Axila/cirurgia , Perna (Membro)/cirurgia , Procedimentos Endovasculares/métodos , Stents , Resultado do Tratamento , Aneurisma Ilíaco/cirurgia
10.
J Cardiovasc Surg (Torino) ; 65(2): 85-98, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38635284

RESUMO

Endovascular aortic repair (EVAR) is nowadays the establishment treatment for patients with abdominal aortic aneurysm (AAA) both in elective and urgent setting. Despite the large applicability and satisfactory results, the presence of hostile iliac anatomy affects both technical and clinical success. This narrative review aimed to report the impact of iliac access and related adjunctive procedures in patients undergoing EVAR in elective and non-elective setting. Hostile iliac access can be defined in presence of narrowed, tortuous, calcified, or occluded iliac arteries. These iliac characteristics can be graded by the anatomic severity grade score to quantitatively assess anatomic complexity before undergoing treatment. Literature shows that iliac hostility has an impact on device navigability, insertion and perioperative and postoperative results. Overall, it has been correlated to higher rate of access issues, representing up to 30% of the first published EVAR experience. Recent innovations with low-profile endografts have reduced large-bore sheaths related issues. However, iliac-related complications still represent an issue, and several adjunctive endovascular and surgical strategies are nowadays available to overcome these complications during EVAR. In urgent settings iliac hostility can significantly impact on particular time sensitive procedures. Moreover, in case of severe hostility patients might be written off for EVAR repair might be inapplicable, exposing to higher mortality/morbidity risk in this urgent/emergent setting. In conclusion, an accurate anatomical evaluation of iliac arteries during preoperative planning, materials availability, and skilled preparation to face iliac-related issues are crucial to address these challenges.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Cirúrgicos Eletivos , Procedimentos Endovasculares , Artéria Ilíaca , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Artéria Ilíaca/cirurgia , Artéria Ilíaca/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Resultado do Tratamento , Fatores de Risco , Prótese Vascular , Complicações Pós-Operatórias/etiologia
11.
J Cardiovasc Surg (Torino) ; 65(2): 99-105, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38551514

RESUMO

The initial success and widespread adoption of endovascular aneurysm repair (EVAR) for the treatment of abdominal aortic aneurysms have been tempered by numerous reports of secondary interventions and increased long-term mortality compared with open repair. Over the past decade, several studies on postoperative sac dynamics after EVAR have suggested that the presence of sac regression is a benign feature with a favorable prognosis. Conversely, increasing sacs and even stable sacs can be indicators of more unstable sac behavior with worse outcomes in the long-term. Endoleaks were initially perceived as the main drivers of sac behavior. However, the observation that sac regression can occur in the presence of endoleaks, and vice versa - increasing sacs without evidence of endoleak - on imaging studies, suggests the involvement of other contributing factors. These factors can be divided into anatomical factors, patient characteristics, sac thrombus composition, and device-related factors. The shift of interest away from especially type 2 endoleaks is further supported by promising results with the use of EndoAnchors regarding postoperative sac behavior. This review provides an overview of the existing literature on the implications and known risk factors of post-EVAR sac behavior, describes the accurate measurement of sac behavior, and discusses the use of EndoAnchors to promote sac regression.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Endoleak , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Endoleak/etiologia , Fatores de Risco , Resultado do Tratamento , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Desenho de Prótese
13.
Trials ; 25(1): 214, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38528619

RESUMO

BACKGROUND: Endovascular repair of aortic aneurysmal disease is established due to perceived advantages in patient survival, reduced postoperative complications, and shorter hospital lengths of stay. High spatial and contrast resolution 3D CT angiography images are used to plan the procedures and inform device selection and manufacture, but in standard care, the surgery is performed using image-guidance from 2D X-ray fluoroscopy with injection of nephrotoxic contrast material to visualise the blood vessels. This study aims to assess the benefit to patients, practitioners, and the health service of a novel image fusion medical device (Cydar EV), which allows this high-resolution 3D information to be available to operators at the time of surgery. METHODS: The trial is a multi-centre, open label, two-armed randomised controlled clinical trial of 340 patient, randomised 1:1 to either standard treatment in endovascular aneurysm repair or treatment using Cydar EV, a CE-marked medical device comprising of cloud computing, augmented intelligence, and computer vision. The primary outcome is procedural time, with secondary outcomes of procedural efficiency, technical effectiveness, patient outcomes, and cost-effectiveness. Patients with a clinical diagnosis of AAA or TAAA suitable for endovascular repair and able to provide written informed consent will be invited to participate. DISCUSSION: This trial is the first randomised controlled trial evaluating advanced image fusion technology in endovascular aortic surgery and is well placed to evaluate the effect of this technology on patient outcomes and cost to the NHS. TRIAL REGISTRATION: ISRCTN13832085. Dec. 3, 2021.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Análise Custo-Benefício , Computação em Nuvem , Procedimentos Endovasculares/métodos , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
14.
Ann Vasc Surg ; 103: 122-132, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38387799

RESUMO

BACKGROUND: In endovascular aortic repair (EVAR), preemptive embolization of sac branch vessels is effective in preventing postoperative type II endoleak (T2EL). However, this technique has not been widely adopted especially for lumbar arteries (LAs) because of technical difficulties and time constraints. This study aimed to investigate the efficacy of nonselective sac coil embolization, which is a simpler surgical method, in postoperative sac shrinkage for patients at a high risk of T2EL from LAs. METHODS: We retrospectively assessed 76 patients who underwent elective EVAR for abdominal aortic aneurysm with 4 or more patent LAs or at least 1 patent LA of ≥2 mm at our hospital between January 2014 and December 2022. The patients who underwent sac coil embolization were included in Group Ⅰ (n = 20), and the others were divided into 2 groups: those with an inferior mesenteric artery that was originally occluded or embolized by coils or stent graft bodies (Group Ⅱ, n = 21), and those without that (Group Ⅲ, n = 35). In Group Ⅰ, 0.035-inch coils were inserted into the sac after complete stent graft deployment. The cumulative incidence of sac shrinkage (≥5 mm) was compared between the groups. Further, univariable and multivariable Cox regression analyses were used to determine the predictors of sac shrinkage. RESULTS: Sac shrinkage (≥5 mm) was observed more frequently in Group Ⅰ (50%) than in Group Ⅱ (19%) and Group Ⅲ (17%) (P = 0.052 and 0.043, respectively). The cumulative incidence of sac shrinkage was significantly higher in Group Ⅰ than in Group Ⅱ (log-rank P = 0.039) and Group Ⅲ (log-rank P = 0.024). Multivariable Cox regression analyses revealed that sac embolization was a significant predictor of sac shrinkage (hazard ratio, 4.23; 95% confidence interval, 1.66-10.8; P = 0.003). CONCLUSIONS: Nonselective sac coil embolization in EVAR is potentially effective for sac shrinkage in the early postoperative phase in patients at high risk of T2EL from LAs. This simple procedure may improve prognosis after EVAR.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Embolização Terapêutica , Endoleak , Procedimentos Endovasculares , Humanos , Endoleak/etiologia , Endoleak/prevenção & controle , Endoleak/terapia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Masculino , Estudos Retrospectivos , Embolização Terapêutica/efeitos adversos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Idoso , Feminino , Fatores de Risco , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Resultado do Tratamento , Idoso de 80 Anos ou mais , Fatores de Tempo , Medição de Risco , Prótese Vascular , Stents , Correção Endovascular de Aneurisma
15.
Ann Vasc Surg ; 102: 9-16, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38301847

RESUMO

BACKGROUND: Endoleaks are the most common complication after endovascular aneurysm repair (EVAR). Computed tomography angiography (CTA) is presently the golden standard for lifelong surveillance after EVAR. Several studies and meta-analyses have shown contrast-enhanced ultrasound (CEUS) to be a good alternative. The main goal of our study was to further validate the inclusion of CEUS in follow-up examination protocols for the systematic surveillance after EVAR. METHODS: A retrospective analysis of patients who had received CEUS as part of their routine surveillance after EVAR at our center was conducted. Detection rate and classification of endoleak types were compared between available postinterventional CTA/magnetic resonance angiography and follow-up CEUS examinations. Last preinterventional CTAs before EVAR served as baselines with focus on potential cofactors such as age, body mass index, maximum aortic aneurysm diameters, endoleak orientation, and distance-to-surface influencing detection rates and classification. RESULTS: In total, 101 patients were included in the analysis. Forty-four endoleaks (43.5% of cases) were detected by either initial CEUS or CTA, mostly type II (37.6% of the included patients). Initial CEUS showed an endoleak sensitivity of 91.2%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 84.6%. No covariate with an influence on the correct classification could be identified either for CEUS or CT. CONCLUSIONS: CEUS should be considered a valid complementary method to CTA in the lifelong surveillance after EVAR. As type II endoleaks seem to be a common early-term, sometimes spontaneously resolving complication that can potentially be missed by CTA, we suggest combined follow-up protocols including CEUS in the early on postinterventional assessment.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Meios de Contraste , Correção Endovascular de Aneurisma , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Seguimentos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Aortografia/métodos , Estudos Retrospectivos , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Tomografia Computadorizada por Raios X
16.
Ann Vasc Surg ; 102: 152-159, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38307230

RESUMO

BACKGROUND: Unlike western countries, which have reported distinct decreases in incidence of ruptured abdominal aortic aneurysm (rAAA) over the last few decades, epidemiologic studies in Korea have not shown significant changes in incidence or mortality of rAAA. The purpose of this study was to analyze the changes in rAAA treatment outcomes and various associated risk factors over the past 2 decades. METHODS: A 20-year retrospective multicenter review for rAAA cases from the period of January 2000 to December 2020 was undertaken. Preoperative, intraoperative and postoperative clinical data were extracted for patients diagnosed with rAAA. For analysis, outcomes from the early era, defined as patients treated between January 1, 2000, and December 31, 2010, were compared with outcomes from the late era, defined as patients treated between January 1, 2011, and December 31, 2020. RESULTS: The total in-hospital mortality was 34.1% in the early era compared to 44.8% in the late era. Patients in the late era were older than those in the early era (75.2 ± 10.3 years vs. 70.3 ± 8.9 years; P = 0.009). Treatment with rAAA endovascular aneurysm repair increased from 2.3% in early to 13.8% in late era (P = 0.031). In the early era, more patients were operated by experienced surgeons than the late era (78.1% vs. 45.9%; P = 0.002). The emergency room to operating room time did not show improvement over the 20 years. CONCLUSIONS: The results indicate that mortality rate of rAAA in Korea has not changed over the last 2 decades. The study suggests the need for national preventive strategies, improved systemic coordination, and potential centralization of vascular services to enhance survival rates for rAAA.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Resultado do Tratamento , Implante de Prótese Vascular/efeitos adversos , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/cirurgia , Ruptura Aórtica/etiologia , Fatores de Risco , República da Coreia/epidemiologia , Estudos Retrospectivos , Complicações Pós-Operatórias/etiologia
17.
Acta Anaesthesiol Scand ; 68(5): 693-701, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38415353

RESUMO

BACKGROUND: Patients with ruptured abdominal aortic aneurysm (rAAA) require immediate vascular treatment to survive. The use of prehospital point-of-care ultrasound (POCUS) may support clinical assessment, correct diagnosis, appropriate triage and reduce system delay. The aim was to study the process of care and outcome in patients receiving prehospital POCUS versus patients not receiving prehospital POCUS in patients with rAAA, ruptured iliac aneurysm or impending aortic rupture. METHODS: We performed a retrospective cohort study in patients diagnosed with rAAA in the Central Denmark Region treated by a prehospital critical care physician from 1 January 2017 to 31 December 2021. Performance of prehospital POCUS was extracted from the prehospital electronic health records. System delay was defined as the time from the emergency phone call to the emergency medical service dispatch centre until the start of surgery. Data on patients primary hospital admission to a centre with/without vascular treatment expertise, treatments and complications including death were extracted from electronic health records. RESULTS: We included 169 patients; prehospital POCUS was performed in 124 patients (73%). Emergency surgical treatment was performed in 71 patients. The overall survival in the POCUS group was 39% versus 16% in the NO POCUS group (hazard ratio (HR) (95% 0.60, 95% CI: 0.41-0.89, p = .011). In the POCUS group 99/124 (80%) were directly admitted to a vascular surgical centre versus 25/45 (56%) in the NO POCUS, RD 24% (95% CI: 8-40)), (p = .002). In the POCUS group, system delay was a median of 142 minutes (interquartile range (IQR) 121-189) and a median of 232 minutes (IQR 166-305) in the NO POCUS group (p = .006). In a multivariable analysis incorporating age, sex, previously known rAAA, and typical clinical symptoms of rAAA, the HR for death was 0.57, 95% CI 0.38-0.86 (p = .008) favouring prehospital POCUS. CONCLUSIONS: Prehospital POCUS was associated with reduced time to treatment, higher chance of operability and significantly higher 30-day survival in patients with rAAA, ruptured iliac aneurysm or impending rupture of an AAA in this retrospective study. Residual confounding cannot be excluded. This study supports the clinical relevance of prehospital POCUS of the abdominal aorta.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Serviços Médicos de Emergência , Procedimentos Endovasculares , Aneurisma Ilíaco , Humanos , Estudos Retrospectivos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/cirurgia , Aneurisma Ilíaco/etiologia , Sistemas Automatizados de Assistência Junto ao Leito , Resultado do Tratamento , Fatores de Risco
18.
Ann Vasc Surg ; 102: 64-73, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38301848

RESUMO

BACKGROUND: Local anesthesia (LA) is sparsely used in endovascular aneurysm repair (EVAR) despite short-term benefit, likely secondary to concerns over patient movement preventing accurate endograft deployment. The objective of this study is to examine the association between anesthesia type and endoleak, sac regression, reintervention, and mortality. METHODS: The Vascular Quality Initiative database was queried for all EVAR cases from 2014 to 2022. Patients were included if they underwent percutaneous elective EVAR with anatomical criteria within instructions for use of commercially approved endografts. Multivariable logistic regression with propensity score weighting was used to determine the association between anesthesia type on the risk of any endoleak noted by intraoperative completion angiogram and sac regression. Multivariable survival analysis with propensity score weighting was used to determine the association between anesthesia type and endoleak at 1 year, long-term reintervention, and mortality. RESULTS: Thirteen thousand nine hundred thirty two EVARs met inclusion criteria: 1,075 (8%) LA and 12,857 (92%) general anesthesia (GA). On completion angiogram, LA was associated with fewer rates of any endoleaks overall (16% vs. 24%, P < 0.001). On multivariable analysis with propensity score weighting, LA was associated with similar adjusted odds of any endoleak on intraoperative completion angiogram (odds ratio [OR] 0.56, 95% confidence interval [CI] 0.47-0.68) as well as combined type 1a and type 1b endoleaks (OR 0.72, 95% CI 0.47-1.09). Follow-up computed tomography imaging at 1 year was available for 4,892 patients, 377 (8%) LA and 4,515 (92%) GA. At 1 year, LA was associated with similar rate of freedom from any endoleaks compared to GA (0.66 [95% CI 0.63-0.69] vs. 0.71 [95% CI 0.70-0.72], P = 0.663) and increased rates of sac regression (50% vs. 45%, P = 0.040). On multivariable analysis with propensity score weighting, LA and GA were associated with similar adjusted odds of sac regression (OR 1.22, 95% CI 0.97-1.55). LA and GA had similar rates of endoleak at 1 year (hazard ratio [HR] 0.14, 95% CI 0.63-1.07); however, LA was associated with decreased hazards of combined type 1a and 1b endoleaks at 1 year (HR 0.87, 95% CI 0.80-0.96). LA and GA had similar adjusted long-term reintervention rate (HR 0.77, 95% CI 0.44-1.38) and long-term mortality (HR 1.100, 95% CI 079-1.25). CONCLUSIONS: LA is not associated with increased adjusted rates of any endoleak on completion angiogram or at 1-year follow-up compared to GA. LA is associated with decreased adjusted rates of type 1a and type 1b endoleak at 1 year, but similar rates of sac regression, long-term reintervention, and mortality. Concerns for accurate graft deployment should not preclude use of LA and LA should be increasingly considered when deciding on anesthetic type for standard elective EVAR.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Anestesia Local/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Fatores de Risco , Resultado do Tratamento , Aortografia/métodos , Estudos Retrospectivos
19.
Ann Vasc Surg ; 102: 101-109, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38307225

RESUMO

BACKGROUND: Epidural analgesia (EA) is recommended along with general anesthesia (GA) for patients undergoing open abdominal aortic aneurysm repair (AAA) and is known to be associated with improved postoperative outcomes. This study evaluates inequities in using this superior analgesic approach and further assesses the disparities at patient and hospital levels. METHODS: A retrospective analysis was performed using the Vascular Quality Initiative database of adult patients undergoing elective open AAA repair between 2003 and 2022. Patients were grouped and analyzed based on anesthesia utilization, that is, EA + GA (Group I) and GA only (Group II). Study groups were further stratified by race, and outcomes were studied. Univariate and multivariate analyses were performed to study the impact of race on the utilization of EA with GA. A subgroup analysis was also carried out to learn the EA analgesia utilization in hospitals performing open AAA with the least to most non-White patients. RESULTS: A total of 8,940 patients were included in the study, of which EA + GA (Group I) comprised n = 4,247 (47.5%) patients, and GA (Group II) had n = 4,693 (52.5%) patients. Based on multivariate regression analysis, the odds ratio of non-White patients receiving both EA and GA for open AAA repair compared to White patients was 0.76 (95% confidence interval: 0.53-0.72, P < 0.001). Of the patients who received both EA + GA, non-White race was associated with increased length of intensive care unit stay and a longer total length of hospital stay compared to White patients. Hospitals with the lowest quintile of minorities had the highest utilization of EA + GA for all patients compared to the highest quintile. CONCLUSIONS: Non-White patients are less likely to receive the EA + GA than White patients while undergoing elective open AAA repair, demonstrating a potential disparity. Also, this disparity persists at the hospital level, with hospitals with most non-White patients having the least EA utilization, pointing toward system-wide disparities.


Assuntos
Analgesia Epidural , Anestesia Epidural , Aneurisma da Aorta Abdominal , Procedimentos Endovasculares , Humanos , Estados Unidos , Analgesia Epidural/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Anestesia Geral/efeitos adversos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Fatores de Risco
20.
CMAJ ; 196(4): E112-E120, 2024 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-38316457

RESUMO

BACKGROUND: Screening programs for abdominal aortic aneurysm (AAA) are not available in Canada. We sought to determine the effectiveness and costutility of AAA screening in Ontario. METHODS: We compared one-time ultrasonography-based AAA screening for people aged 65 years to no screening using a fully probabilistic Markov model with a lifetime horizon. We estimated life-years, quality-adjusted life-years (QALYs), AAA-related deaths, number needed to screen to prevent 1 AAA-related death and costs (in Canadian dollars) from the perspective of the Ontario Ministry of Health. We retrieved model inputs from literature, Statistics Canada, and the Ontario Case Costing Initiative. RESULTS: Screening reduced AAA-related deaths by 84.9% among males and 81.0% among females. Compared with no screening, screening resulted in 0.04 (18.96 v. 18.92) additional life-years and 0.04 (14.95 v. 14.91) additional QALYs at an incremental cost of $80 per person among males. Among females, screening resulted in 0.02 (21.25 v. 21.23) additional life-years and 0.01 (16.20 v. 16.19) additional QALYs at an incremental cost of $11 per person. At a willingness-to-pay of $50 000 per year, screening was cost-effective in 84% (males) and 90% (females) of model iterations. Screening was increasingly cost-effective with higher AAA prevalence. INTERPRETATION: Screening for AAA among people aged 65 years in Ontario was associated with fewer AAA-related deaths and favourable cost-effectiveness. To maximize QALY gains per dollar spent and AAA-related deaths prevented, AAA screening programs should be designed to ensure that populations with high prevalence of AAA participate.


Assuntos
Aneurisma da Aorta Abdominal , Programas de Rastreamento , Masculino , Feminino , Humanos , Ontário/epidemiologia , Análise Custo-Benefício , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Anos de Vida Ajustados por Qualidade de Vida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA