Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.176
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Acta Neurochir (Wien) ; 166(1): 203, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38713241

RESUMO

PURPOSE: Stroke, the second leading cause of death globally, often involves ischemia in the vertebrobasilar territory. This condition is underexplored, despite significant morbidity and mortality risks. The purpose of this study is to present a case of occipital artery to V3 segment vertebral artery bypass, emphasizing the role of quantitative magnetic resonance angiography (qMRA) in assessing flow and guiding surgical intervention. METHODS: A 66-year-old man with bilateral vertebral artery occlusion presented acute symptoms. qMRA was employed to evaluate flow dynamics and determine the feasibility of a flow augmentation bypass surgery. The occipital artery to left vertebral artery bypass (OA-to-VA) was performed, utilizing an inverted hockey-stick incision and an antegrade inside-out technique. The patency of the bypass was confirmed using both Doppler probe and Indocyanine green. RESULTS: Postoperative assessments, including computed tomography angiography (CTA) and qMRA, demonstrated the patency of the bypass with improved flow in the basilar artery and left vertebral artery. The patient's condition remained stable postoperatively, with residual peripheral palsy of the left facial nerve. CONCLUSION: In conclusion, the presented case illustrates the efficacy of the OA-to-VA bypass in addressing symptomatic bilateral vertebral artery occlusion. The study underscores the pivotal role of qMRA in pre- and postoperative assessments, providing noninvasive flow quantification for diagnostic considerations and long-term follow-up in patients with vertebrobasilar insufficiency.


Assuntos
Revascularização Cerebral , Angiografia por Ressonância Magnética , Artéria Vertebral , Insuficiência Vertebrobasilar , Humanos , Masculino , Idoso , Insuficiência Vertebrobasilar/cirurgia , Insuficiência Vertebrobasilar/diagnóstico por imagem , Artéria Vertebral/cirurgia , Artéria Vertebral/diagnóstico por imagem , Revascularização Cerebral/métodos , Angiografia por Ressonância Magnética/métodos , Resultado do Tratamento
2.
Neuroimaging Clin N Am ; 34(2): 251-260, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38604709

RESUMO

Conventional imaging modalities, such as computed tomography angiography, MR angiography, transcranial Doppler ultrasonography, and digital subtraction angiography, are utilized in evaluating intraluminal or intravascular pathology of the intracranial vessels. Limitations of luminal imaging techniques can lead to inaccurate diagnosis, evaluation, and risk stratification, as many cerebrovascular pathologies contain an extrinsic vessel wall component. Furthermore, vessel wall imaging can provide information regarding extent, treatment response, and biopsy targets for vasculitis cases. Overall, while vessel wall imaging can provide robust data regarding intracranial pathologies, further prospective, multicenter studies are required to improve diagnostic application and accuracy.


Assuntos
Aterosclerose , Vasculite , Humanos , Vasculite/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X , Angiografia Digital , Imageamento por Ressonância Magnética/métodos
3.
Neurosurg Focus ; 56(3): E10, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38428010

RESUMO

OBJECTIVE: Spinal dural arteriovenous fistulas (SDAVFs) often go undiagnosed, leading to irreversible spinal cord dysfunction. Although digital subtraction angiography (DSA) is the gold standard for diagnosing SDAVF, DSA is invasive and operator dependent, with associated risks. MR angiography (MRA) is a promising alternative. This study aimed to evaluate the performance of MRA as an equal alternative to DSA in investigating, diagnosing, and localizing SDAVF. METHODS: Prospectively collected data from a single neurosurgeon at a large tertiary academic center were searched for SDAVFs. Eligibility criteria included any patient with a surgically proven SDAVF in whom preoperative DSA, MRA, or both had been obtained. The eligible patients formed a consecutive series, in which they were divided into DSA and MRA groups. DSA and MRA were the index tests that were compared to the surgical SDAVF outcome, which was the reference standard. Accurate diagnosis was considered to have occurred when the imaging report matched the operative diagnosis to the correct spinal level. Comparisons used a two-sample t-test for continuous variables and Fisher-Freeman-Halton's exact test for categorical variables, with p < 0.05 specifying significance. Univariate, bivariate, and multivariate analyses were conducted to investigate group associations with DSA and MRA accuracy. Positive predictive value, sensitivity, and accuracy were calculated. RESULTS: A total of 27 patients with a mean age of 63 years underwent surgery for SDAVF. There were 19 male (70.4%) and 8 female (29.6%) patients, and the mean duration of symptoms at the time of surgery was 14 months (range 2-48 months). Seventeen patients (63%) presented with bowel or bladder incontinence. Bivariate analysis of the DSA and MRA groups further revealed no significant relationships between the characteristics and accuracy of SDAVF diagnosis. MRA was found to be more sensitive and accurate (100% and 73.3%) than DSA (85.7% and 69.2%), with a subanalysis of the patients with both preoperative MRA and DSA showing that MRA had a greater positive predictive value (78.6 vs 72.7), sensitivity (100 vs 72.7), and accuracy (78.6 vs 57.1) than DSA. CONCLUSIONS: In surgically proven cases of SDAVFs, the authors determined that MRA was more accurate than DSA for SDAVF diagnosis and localization to the corresponding vertebral level. Incomplete catheterization at each vertebral level may result in the failure of DSA to detect SDAVF.


Assuntos
Malformações Vasculares do Sistema Nervoso Central , Angiografia por Ressonância Magnética , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Angiografia por Ressonância Magnética/métodos , Angiografia Digital/métodos , Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Malformações Vasculares do Sistema Nervoso Central/cirurgia , Medula Espinal/diagnóstico por imagem , Medula Espinal/cirurgia , Valor Preditivo dos Testes
4.
Comput Biol Med ; 171: 107987, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38350395

RESUMO

OBJECTIVE: Alignment between preoperative images (high-resolution magnetic resonance imaging, magnetic resonance angiography) and intraoperative medical images (digital subtraction angiography) is currently required in neurointerventional surgery. Treating a lesion is usually guided by a 2D DSA silhouette image. DSA silhouette images increase procedure time and radiation exposure time due to the lack of anatomical information, but information from MRA images can be utilized to compensate for this in order to improve procedure efficiency. In this paper, we abstract this into the problem of relative pose and correspondence between a 3D point and its 2D projection. Multimodal images have a large amount of noise and anomalies that are difficult to resolve using conventional methods. According to our research, there are fewer multimodal fusion methods to perform the full procedure. APPROACH: Therefore, the paper introduces a registration pipeline for multimodal images with fused dual views is presented. Deep learning methods are introduced to accomplish feature extraction of multimodal images to automate the process. Besides, the paper proposes a registration method based on the Factor of Maximum Bounds (FMB). The key insights are to relax the constraints on the lower bound, enhance the constraints on the upper bounds, and mine more local consensus information in the point set using a second perspective to generate accurate pose estimation. MAIN RESULTS: Compared to existing 2D/3D point set registration methods, this method utilizes a different problem formulation, searches the rotation and translation space more efficiently, and improves registration speed. SIGNIFICANCE: Experiments with synthesized and real data show that the proposed method was achieved in accuracy, robustness, and time efficiency.


Assuntos
Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Angiografia Digital/métodos , Imageamento Tridimensional/métodos , Algoritmos
5.
ACS Appl Mater Interfaces ; 16(8): 9702-9712, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38363797

RESUMO

Magnetic resonance angiography (MRA) contrast agents are extensively utilized in clinical practice due to their capability of improving the image resolution and sensitivity. However, the clinically approved MRA contrast agents have the disadvantages of a limited acquisition time window and high dose administration for effective imaging. Herein, albumin-coated gadolinium-based nanoparticles (BSA-Gd) were meticulously developed for in vivo ultrahigh-resolution MRA. Compared to Gd-DTPA, BSA-Gd exhibits a significantly higher longitudinal relaxivity (r1 = 76.7 mM-1 s-1), nearly 16-fold greater than that of Gd-DTPA, and an extended blood circulation time (t1/2 = 40 min), enabling a dramatically enhanced high-resolution imaging of microvessels (sub-200 µm) and low dose imaging (about 1/16 that of Gd-DTPA). Furthermore, the clinically significant fine vessels were successfully mapped in large mammals, including a circle of Willis, kidney and liver vascular branches, tumor vessels, and differentiated arteries from veins using dynamic contrast-enhanced MRA BSA-Gd, and have superior imaging capability and biocompatibility, and their clinical applications hold substantial promise.


Assuntos
Angiografia por Ressonância Magnética , Nanopartículas , Animais , Angiografia por Ressonância Magnética/métodos , Gadolínio DTPA , Meios de Contraste , Gadolínio , Imageamento por Ressonância Magnética/métodos , Mamíferos
6.
Curr Med Imaging ; 20: 1-6, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38389372

RESUMO

BACKGROUND: Persistent trigeminal artery (PTA) is the most common vascular anastomosis between the carotid artery and vertebrobasilar systems. We report a very rare case of dissecting aneurysm in the right internal carotid artery (ICA) with ipsilateral PTA and discuss its clinical importance. CASE REPORT: A 38-year-old male presented to the emergency department with paroxysmal dysphasia for 6h. Brain magnetic resonance (MR) imaging showed acute cerebral infarction of the right corona radiata and right parietal lobe. Three-dimensional time-of-flight MR angiography (3D TOF MRA) revealed severe stenosis of the petrous segment (C1 portion) of the right internal carotid artery and a PTA originating from the right ICA cavernous segment (C4 portion), with a length of approximately 1.8cm and a diameter of approximately 0.2cm. The ICA segments are all named according to the Bouthilier classification. The basilar artery (BA) under union was well developed. The bilateral posterior communicating arteries were also present. One day later, the high-resolution vessel-wall MR demonstrated a dissecting aneurysm in the C1 portion of the right ICA. The length of the dissecting aneurysm is approximately 4.4cm, the diameter of the true lumen at the most severe stenosis is approximately 0.2cm, and the diameter of the false lumen is approximately 0.8cm. Subsequent digital subtraction angiography (DSA) confirmed a dissecting aneurysm in the C1 portion of the right ICA. The patient was treated conservatively and did not undergo interventional surgery. Four months later, head and neck MRA showed that the right ICA blood flow was smooth and that the dissecting aneurysm had disappeared. The Ethics Committee of Liaocheng People's Hospital approved the research protocol in compliance with the Helsinki Declaration. Written informed consent was obtained from the individual for the publication of any potentially identifiable images or data included in this article. CONCLUSION: Flow alteration with PTA may have influenced the formation of ICA dissection in this patient. Awareness of this is crucial in clinical practice because it can influence treatment options and intervention procedures.


Assuntos
Dissecção Aórtica , Artéria Carótida Interna , Masculino , Humanos , Adulto , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/patologia , Artéria Carótida Interna/cirurgia , Constrição Patológica/patologia , Imageamento por Ressonância Magnética , Angiografia por Ressonância Magnética/métodos , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem
7.
Sci Rep ; 14(1): 4490, 2024 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-38396152

RESUMO

This study aimed to assess the performance of arterial-spin labeling MRA (ASL-MRA) for visualizing the external carotid artery (ECA) branches in comparison with time-of-flight MRA (TOF-MRA) and CT angiography (CTA). We retrospectively selected 31 consecutive patients, who underwent both MRAs and CTA, prior to the intra-arterial chemoradiotherapy (IACRT) for head and neck cancer. Four patients underwent IACRT bilaterally, so we analyzed 35 ECAs. Pseudo-continuous, three-dimensional ASL using a turbo field echo sequence was acquired. For the TOF-MRA and CTA, clinically used parameters were applied. Two observers evaluated each ECA branch with reference to the angiogram at the IACRT, using five-point scale, in consensus. Friedman test for multiple comparisons was applied. ASL-MRA and CTA better visualized the superior thyroid, lingual, facial, submental, transverse facial, and internal maxillary arteries (IMAs) better than TOF-MRA (p < 0.05). In addition, CTA was superior to ASL-MRA in visualizing only submental artery among these arteries (p = 0.0005). Alternatively, the ASL-MRA was superior for visualizing the middle meningeal artery (MMA) and IMA, compared to the CTA (p = 0.0001 and 0.0007, respectively). ASL-MRA was superior to the TOF-MRA and similar to the CTA in visualizing most of ECA branches. Furthermore, ASL-MRA can better visualize the periphery of MMA and IMA than CTA.


Assuntos
Artéria Carótida Externa , Angiografia por Ressonância Magnética , Humanos , Artéria Carótida Externa/diagnóstico por imagem , Marcadores de Spin , Estudos Retrospectivos , Angiografia por Ressonância Magnética/métodos , Artérias
8.
Clin Neuroradiol ; 34(2): 391-401, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38277058

RESUMO

PURPOSE: To quantify the effects of CSF pressure alterations on intracranial venous morphology and hemodynamics in idiopathic intracranial hypertension (IIH) and spontaneous intracranial hypotension (SIH) and assess reversibility when the underlying cause is resolved. METHODS: We prospectively examined venous volume, intracranial venous blood flow and velocity, including optic nerve sheath diameter (ONSD) as a noninvasive surrogate of CSF pressure changes in 11 patients with IIH, 11 age-matched and sex-matched healthy controls and 9 SIH patients, before and after neurosurgical closure of spinal dural leaks. We applied multiparametric MRI including 4D flow MRI, time-of-flight (TOF) and T2-weighted half-Fourier acquisition single-shot turbo-spin echo (HASTE). RESULTS: Sinus volume overlapped between groups at baseline but decreased after treatment of intracranial hypotension (p = 0.067) along with a significant increase of ONSD (p = 0.003). Blood flow in the middle and dorsal superior sagittal sinus was remarkably lower in patients with higher CSF pressure (i.e., IIH versus controls and SIH after CSF leak closure) but blood flow velocity was comparable cross-sectionally between groups and longitudinally in SIH. CONCLUSION: We were able to demonstrate the interaction of CSF pressure, venous volumetry, venous hemodynamics and ONSD using multiparametric brain MRI. Closure of CSF leaks in SIH patients resulted in symptoms suggestive of increased intracranial pressure and caused a subsequent decrease of intracranial venous volume and of blood flow within the superior sagittal sinus while ONSD increased. In contrast, blood flow parameters from 4D flow MRI did not discriminate IIH, SIH and controls as hemodynamics at baseline overlapped at most vessel cross-sections.


Assuntos
Pressão do Líquido Cefalorraquidiano , Circulação Cerebrovascular , Hipotensão Intracraniana , Pseudotumor Cerebral , Humanos , Feminino , Masculino , Adulto , Hipotensão Intracraniana/diagnóstico por imagem , Hipotensão Intracraniana/fisiopatologia , Circulação Cerebrovascular/fisiologia , Pseudotumor Cerebral/fisiopatologia , Pseudotumor Cerebral/diagnóstico por imagem , Pseudotumor Cerebral/cirurgia , Pressão do Líquido Cefalorraquidiano/fisiologia , Veias Cerebrais/diagnóstico por imagem , Veias Cerebrais/fisiopatologia , Pessoa de Meia-Idade , Angiografia por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Imageamento Tridimensional/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Sensibilidade e Especificidade , Hemodinâmica/fisiologia , Hipertensão Intracraniana/fisiopatologia , Hipertensão Intracraniana/diagnóstico por imagem
9.
Rofo ; 196(1): 36-51, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37467779

RESUMO

BACKGROUND: Arterial spin labeling (ASL) is a magnetic resonance imaging (MRI)-based technique using labeled blood-water of the brain-feeding arteries as an endogenous tracer to derive information about brain perfusion. It enables the assessment of cerebral blood flow (CBF). METHOD: This review aims to provide a methodological and technical overview of ASL techniques, and to give examples of clinical use cases for various diseases affecting the central nervous system (CNS). There is a special focus on recent developments including super-selective ASL (ssASL) and time-resolved ASL-based magnetic resonance angiography (MRA) and on diseases commonly not leading to characteristic alterations on conventional structural MRI (e. g., concussion or migraine). RESULTS: ASL-derived CBF may represent a clinically relevant parameter in various pathologies such as cerebrovascular diseases, neoplasms, or neurodegenerative diseases. Furthermore, ASL has also been used to investigate CBF in mild traumatic brain injury or migraine, potentially leading to the establishment of imaging-based biomarkers. Recent advances made possible the acquisition of ssASL by selective labeling of single brain-feeding arteries, enabling spatial perfusion territory mapping dependent on blood flow of a specific preselected artery. Furthermore, ASL-based MRA has been introduced, providing time-resolved delineation of single intracranial vessels. CONCLUSION: Perfusion imaging by ASL has shown promise in various diseases of the CNS. Given that ASL does not require intravenous administration of a gadolinium-based contrast agent, it may be of particular interest for investigations in pediatric cohorts, patients with impaired kidney function, patients with relevant allergies, or patients that undergo serial MRI for clinical indications such as disease monitoring. KEY POINTS: · ASL is an MRI technique that uses labeled blood-water as an endogenous tracer for brain perfusion imaging.. · It allows the assessment of CBF without the need for administration of a gadolinium-based contrast agent.. · CBF quantification by ASL has been used in several pathologies including brain tumors or neurodegenerative diseases.. · Vessel-selective ASL methods can provide brain perfusion territory mapping in cerebrovascular diseases.. · ASL may be of particular interest in patient cohorts with caveats concerning gadolinium administration..


Assuntos
Transtornos Cerebrovasculares , Transtornos de Enxaqueca , Doenças Neurodegenerativas , Humanos , Criança , Meios de Contraste , Marcadores de Spin , Gadolínio , Imageamento por Ressonância Magnética/métodos , Artérias , Angiografia por Ressonância Magnética/métodos , Transtornos Cerebrovasculares/diagnóstico por imagem , Água
10.
J Magn Reson Imaging ; 59(3): 797-811, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37589377

RESUMO

Perforator flap magnetic resonance angiography (MRA) has emerged as a widely accepted and preferred modality for perforator flap mapping at several institutions. Autologous perforator flaps are a type of reconstructive microsurgical technique that involves transferring skin and fat from one part of the patient's body to another to replace tissue lost due to trauma, cancer resection, or other reasons. Autologous perforator flaps are based on a specific perforating blood vessel perfusing the transferred tissue. Hence, the surgery relies on the precise identification and mapping of perforating vessels to ensure successful outcomes. With its superior soft tissue contrast and multiplanar imaging capabilities, MRA has shown great potential in providing accurate and detailed visualization of perforator anatomy, size, and course. This review article summarizes the current literature on perforator flap MRA, including its technical considerations, imaging protocols, postprocessing, and reporting, specifically for autologous breast reconstructions. The advantages and limitations of MRA in evaluating perforator flaps are discussed, including its role in preoperative planning, intraoperative guidance, and postoperative assessment. Anatomy, brief surgical technique, specific technical modifications, and reporting of most commonly performed autologous breast flaps are described. Recent advancements in Perforator flap surgery and MRA techniques are discussed. Additionally, we examine the emerging role of artificial intelligence and machine learning in improving the accuracy and efficiency of perforator flap MRA interpretation. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 5.


Assuntos
Mamoplastia , Retalho Perfurante , Humanos , Angiografia por Ressonância Magnética/métodos , Inteligência Artificial , Artérias Epigástricas/patologia , Mamoplastia/métodos
11.
Diagn Interv Radiol ; 30(2): 124-134, 2024 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-37789677

RESUMO

PURPOSE: The reproducibility of relative cerebral blood volume (rCBV) measurements among readers with different levels of experience is a concern. This study aimed to investigate the inter-reader reproducibility of rCBV measurement of glioblastomas using the hotspot method in dynamic susceptibility contrast perfusion magnetic resonance imaging (DSC-MRI) with various strategies. METHODS: In this institutional review board-approved single-center study, 30 patients with glioblastoma were retrospectively evaluated with DSC-MRI at a 3.0 Tesla scanner. Three groups of reviewers, including neuroradiologists, general radiologists, and radiology residents, calculated the rCBV based on the number of regions of interest (ROIs) and reference areas. For statistical analysis of feature reproducibility, the intraclass correlation coefficient (ICC) and Bland-Altman plots were used. Analyses were made among individuals, reader groups, reader-group pooling, and a population that contained all of them. RESULTS: For individuals, the highest inter-reader reproducibility was observed between neuroradiologists [ICC: 0.527; 95% confidence interval (CI): 0.21-0.74] and between residents (ICC: 0.513; 95% CI: 0.20-0.73). There was poor reproducibility in the analyses of individuals with different levels of experience (ICC range: 0.296-0.335) and in reader-wise and group-wise pooling (ICC range: 0.296-0.335 and 0.397-0.427, respectively). However, an increase in ICC values was observed when five ROIs were used. In an analysis of all strategies, the ICC for the centrum semiovale was significantly higher than that for contralateral white matter (P < 0.001). CONCLUSION: The inter-reader reproducibility of rCBV measurement was poor to moderate regardless of whether it was calculated by neuroradiologists, general radiologists, or residents, which may indicate the need for automated methods. Choosing five ROIs and using the centrum semiovale as a reference area may increase reliability for all users.


Assuntos
Neoplasias Encefálicas , Glioblastoma , Humanos , Glioblastoma/diagnóstico por imagem , Glioblastoma/irrigação sanguínea , Glioblastoma/patologia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/irrigação sanguínea , Neoplasias Encefálicas/patologia , Volume Sanguíneo Cerebral , Reprodutibilidade dos Testes , Estudos Retrospectivos , Meios de Contraste , Angiografia por Ressonância Magnética/métodos , Perfusão , Imageamento por Ressonância Magnética/métodos
12.
Clin Neuroradiol ; 34(2): 351-360, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38157019

RESUMO

PURPOSE: Perfusion-weighted (PWI) magnetic resonance imaging (MRI) and O­(2-[18F]fluoroethyl-)-l-tyrosine ([18F]FET) positron emission tomography (PET) are both useful for discrimination of progressive disease (PD) from radiation necrosis (RN) in patients with gliomas. Previous literature showed that the combined use of FET-PET and MRI-PWI is advantageous; hhowever the increased diagnostic performances were only modest compared to the use of a single modality. Hence, the goal of this study was to further explore the benefit of combining MRI-PWI and [18F]FET-PET for differentiation of PD from RN. Secondarily, we evaluated the usefulness of cerebral blood flow (CBF), mean transit time (MTT) and time to peak (TTP) as previous studies mainly examined cerebral blood volume (CBV). METHODS: In this single center study, we retrospectively identified patients with WHO grades II-IV gliomas with suspected tumor recurrence, presenting with ambiguous findings on structural MRI. For differentiation of PD from RN we used both MRI-PWI and [18F]FET-PET. Dynamic susceptibility contrast MRI-PWI provided normalized parameters derived from perfusion maps (r(relative)CBV, rCBF, rMTT, rTTP). Static [18F]FET-PET parameters including mean and maximum tumor to brain ratios (TBRmean, TBRmax) were calculated. Based on histopathology and radioclinical follow-up we diagnosed PD in 27 and RN in 10 cases. Using the receiver operating characteristic (ROC) analysis, area under the curve (AUC) values were calculated for single and multiparametric models. The performances of single and multiparametric approaches were assessed with analysis of variance and cross-validation. RESULTS: After application of inclusion and exclusion criteria, we included 37 patients in this study. Regarding the in-sample based approach, in single parameter analysis rTBRmean (AUC = 0.91, p < 0.001), rTBRmax (AUC = 0.89, p < 0.001), rTTP (AUC = 0.87, p < 0.001) and rCBVmean (AUC = 0.84, p < 0.001) were efficacious for discrimination of PD from RN. The rCBFmean and rMTT did not reach statistical significance. A classification model consisting of TBRmean, rCBVmean and rTTP achieved an AUC of 0.98 (p < 0.001), outperforming the use of rTBRmean alone, which was the single parametric approach with the highest AUC. Analysis of variance confirmed the superiority of the multiparametric approach over the single parameter one (p = 0.002). While cross-validation attributed the highest AUC value to the model consisting of TBRmean and rCBVmean, it also suggested that the addition of rTTP resulted in the highest accuracy. Overall, multiparametric models performed better than single parameter ones. CONCLUSION: A multiparametric MRI-PWI and [18F]FET-PET model consisting of TBRmean, rCBVmean and PWI rTTP significantly outperformed the use of rTBRmean alone, which was the best single parameter approach. Secondarily, we firstly report the potential usefulness of PWI rTTP for discrimination of PD from RN in patients with glioma; however, for validation of our findings the prospective studies with larger patient samples are necessary.


Assuntos
Neoplasias Encefálicas , Glioma , Tomografia por Emissão de Pósitrons , Lesões por Radiação , Humanos , Masculino , Feminino , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Pessoa de Meia-Idade , Glioma/diagnóstico por imagem , Glioma/radioterapia , Diagnóstico Diferencial , Tomografia por Emissão de Pósitrons/métodos , Adulto , Lesões por Radiação/diagnóstico por imagem , Lesões por Radiação/etiologia , Estudos Retrospectivos , Idoso , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Imagem Multimodal/métodos , Tirosina/análogos & derivados , Necrose/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Progressão da Doença , Circulação Cerebrovascular
13.
J Neurosci Methods ; 401: 110007, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37952831

RESUMO

BACKGROUND: Blood perfusion of the optic nerve (ON) plays a key role in many optic neuropathies. Microvascular changes precede or accompany neuronal changes, and detecting these changes at an early stage may facilitate early treatment to avoid blindness. However, the quantification of ON blood perfusion remains a challenge. This study aimed to evaluate the viability of three-dimensional pseudocontinuous arterial spin labelling (3D-pCASL) MRI for the quantification of ON blood flow (BF). NEW METHOD: The ON segmentation was performed using nnFormer on a cohort of ten participants (4 males, 6 females, 25-59 years old). Subsequently, the mean BF of each ON segment was calculated using whole brain 3D-pCASL image data. RESULTS: The average ON-BF values of the left and right intraorbital segments, left and right intracanalicular segments, left and right intracranial segments, optic chiasma, and left and right optic tract were 41.308 mL/100 g/min, 43.281 mL/100 g/min, 53.188 mL/100 g/min, 57.202 mL/100 g/min, 45.089 mL/100 g/min, 49.554 mL/100 g/min, 42. 326 mL/100 g/min, 43.831 mL/100 g/min and 45.176 mL/100 g/min, respectively. The ON-BF correlated with cerebral BF (r = 0.503, p = 0.024). COMPARISON WITH EXISTING METHOD(S): The 3D-pCASL can measure tissue microvascular blood perfusion in absolute quantitative units with good test-retest repeatability over a wide field of view and without restrictions on depth. The use of the nnFormer makes the measurement easy, objective and reproducible. CONCLUSIONS: The study showed that, 3D-pCASL may be a promising tool for detecting abnormal ON-BF. In particular, 3D-pCASL coupled with the nnFormer provides an objective, reproducible, and reliable method to quantify BF in ON.


Assuntos
Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Angiografia por Ressonância Magnética/métodos , Marcadores de Spin , Circulação Cerebrovascular/fisiologia , Nervo Óptico
14.
Eur J Radiol ; 169: 111184, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37931375

RESUMO

PURPOSE: To investigate whether moyamoya disease (MMD) and atherosclerotic moyamoya syndrome (AS-MMS) differ in vascular morphology and perfusion characteristics using T1w-CUBE imaging and multiple post-labeling delay 3D pseudo-continuous arterial spin labeling imaging (MP 3D-PcASL), and to explore the potential of the combined techniques for accurate diagnosis of both diseases. METHOD: This prospective study enrolled 51 patients with moyamoya vasculopathy, including 26 with MMD and 25 with AS-MMS. All patients underwent digital subtraction angiography (DSA)/magnetic resonance angiography (MRA), T1w-CUBE imaging, and MP 3D-PCASL examinations. Morphological parameters, including the outer diameter, maximum wall thickness, luminal stenosis morphology, degree of wall enhancement, number of collateral vessels, and perfusion parameters, such as cerebral blood flow (CBF) and arterial transit time (ATT), were measured. After univariate analysis between the two groups, logistic regression models based on the derived parameters of T1w-CUBE imaging, MP 3D-PCASL, and combined imaging were implemented, and receiver operating characteristic (ROC) curves were generated to compare the discriminatory power of the different imaging methods for the diagnosis of MMD. RESULTS: With T1w-CUBE imaging, MMD showed a smaller outer diameter (2.76 ± 0.39 vs. 3.07 ± 0.49 mm) and maximum wall thickness (1.27 ± 0.19 vs. 1.49 ± 0.24 mm) than AS-MMS (both P < 0.05). Using MP 3D-pcASL, the resultant CBF (36.64 ± 14.28 vs. 28.77 ± 8.63 mL/100 g/min) was higher in MMD relative to AS-MMS, while an opposite pattern was shown for ATT (1.61 ± 0.09 vs. 1.72 ± 0.13 s; both P < 0.05). Robust diagnostic efficacies for disease differentiation, confirmed by high areas under the ROC curve (AUCs) (>0.808), were separately shown with T1w-CUBE and MP 3D-pcASL derived parameters. However, the combined multivariate logistic regression model showed optimaldiagnostic efficacy(AUC: 0.938; P < 0.05). CONCLUSIONS: Combined T1w-CUBE imaging and MP 3D-PCASL provides distinctive morphological and functional features to evaluate vessel walls and cerebral perfusion, and might help distinguish MMD from AS-MMS.


Assuntos
Doença de Moyamoya , Humanos , Doença de Moyamoya/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos , Artérias , Angiografia por Ressonância Magnética/métodos , Marcadores de Spin , Circulação Cerebrovascular/fisiologia
15.
ACS Appl Bio Mater ; 6(11): 4906-4913, 2023 11 20.
Artigo em Inglês | MEDLINE | ID: mdl-37917917

RESUMO

Contrast-enhanced magnetic resonance angiography is a powerful and effective method to accurately diagnose carotid artery stenosis. Small molecular gadolinium (Gd)-based agents have reliable signal enhancement, but their short circulating time may result in a loss of image resolution due to insufficient vascular filling or contrast agent emptying. Here, we report an MRA imaging approach to diagnose carotid artery stenosis using long-circulating bovine serum albumin (BSA)-Gd2O3 nanoparticles (NPs). The BSA-Gd2O3 NPs synthesized by a simple biomineralization approach exhibit admirable monodispersity, uniform size, favorable aqueous solubility, good biocompatibility, and high relaxivity (14.86 mM-1 s-1 in water, 6.41 mM-1 s-1 in plasma). In vivo MRA imaging shows that outstanding vascular enhancement of BSA-Gd2O3 NPs (0.05 mmol Gd/kg, half the dose in the clinic) can be maintained for at least 2 h, much longer than Gd-DTPA. Vessels as small as 0.3 mm can be clearly observed in MRA images with high resolution. In a rat carotid artery stenosis model, the BSA-Gd2O3 NPs-based MRA enables the precise diagnosis of the severity and location and the therapeutic effect following the surgery of carotid artery stenosis, which provides a method for the theranostics of vascular diseases.


Assuntos
Estenose das Carótidas , Nanopartículas , Ratos , Animais , Angiografia por Ressonância Magnética/métodos , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Meios de Contraste , Gadolínio , Soroalbumina Bovina
16.
Eur J Radiol ; 168: 111145, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37837923

RESUMO

PURPOSE: Carotid intraplaque hemorrhage (IPH) on MRI predicts stroke. Magnetization-prepared rapid acquisition gradient (MP-RAGE) is widely used to detect IPH. CE-MRA is used routinely to assess stenosis. Initial studies indicated that IPH can be identified on mask images of CE-MRA, while Time-of-Flight (TOF) images were reported to have high specificity but lower sensitivity. We investigated the diagnostic accuracy of detecting IPH on mask images of CE-MRA and TOF. METHODS: Thirty-six patients with ≥ 50% stenosis enrolled in the ongoing 2nd European Carotid Surgery Trial underwent carotid MRI. A 5-point quality score was used. Inter-observer agreement between two independent readers was determined. The sensitivity and specificity of IPH detection on mask MRA and TOF were calculated with MP-RAGE as a reference standard. RESULTS: Of the 36 patients included in the current analysis, 66/72 carotid arteries could be scored. The inter-observer agreements for identifying IPH on MP-RAGE, mask, and TOF were outstanding (κ: 0.93, 0.96, and 0.85). The image quality of mask (1.42 ± 0.66) and TOF (2.42 ± 0.66) was significantly lower than MP-RAGE (3.47 ± 0.61). When T1w images were used to delineate the outer carotid wall, very high specificities (>95%) of IPH detection on mask and TOF images were found, while the sensitivity was high for mask images (>81%) and poor for TOF (50-60%). Without these images, the specificity was still high (>97%), while the sensitivity reduced to 62-71%. CONCLUSION: Despite the lower image quality, routinely acquired mask images from CE-MRA, but not TOF, can be used as an alternative to MP-RAGE images to visualize IPH.


Assuntos
Estenose das Carótidas , Humanos , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Constrição Patológica , Angiografia por Ressonância Magnética/métodos , Artérias Carótidas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Hemorragia/diagnóstico por imagem
17.
Surg Radiol Anat ; 45(10): 1287-1293, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37615700

RESUMO

PURPOSE: As the lenticulostriate arteries (LSAs) perfuse neurologically important areas, it is necessary to accurately assess the origin and number of the LSAs before surgery. Although three-dimensional time-of-flight MR angiography (3D-TOF MRA) is a non-invasive procedure, it requires high-resolution (HR) images to depict the LSAs with a small diameter. Therefore, we performed 3D-TOF MRA with the maximum HR (HR-MRA) using a 3 T scanner to examine whether a good depiction of the LSAs, equivalent to that of digital subtraction angiography (DSA), could be obtained. METHODS: Our study group comprised 16 consecutive patients who underwent HR-MRA and 3D-DSA. In both studies, we evaluated the localization of the origin from M1, M2, or A1 segments, their number of stems, and depiction. RESULTS: There was no significant difference in the visualization of the LSAs between HR-MRA and 3D-DSA (P values; M1, M2, and A1 = 0.39, 0.69, and 0.69, respectively), and both the number of stems and the localization of the origin of the LSAs corresponded between the two examinations. CONCLUSION: HR-MRA at 3 T can depict the LSA well. It reveals the number of the LSA stems and the LSA origin comparatively with DSA.


Assuntos
Artérias Cerebrais , Angiografia por Ressonância Magnética , Humanos , Artérias Cerebrais/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Angiografia Digital , Artéria Cerebral Média , Imageamento Tridimensional
18.
Clin Neuroradiol ; 33(4): 1067-1074, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37395788

RESUMO

BACKGROUND: Clinical symptoms in children with suspected malfunction of ventriculoperitoneal shunt may not be specific and difficult to interpret. The presence or absence of ventricular enlargement on magnetic resonance imaging (MRI) does not reliably predict raised intracranial pressure (ICP) in these patients. Therefore, the aim was to investigate the diagnostic utility of 3D venous phase-contrast MR angiography (vPCA) in these patients. MATERIALS: The MR studies of two groups of patients at two different examination dates were retrospectively analyzed; one group without clinical symptoms on both examinations and one with symptoms of shunt dysfunction on one examination receiving surgery. Both MRI examinations had to have been performed including axial T2 weighted (T2-w) images and 3D vPCA. Two (neuro)radiologists evaluated T2-w images alone and in combination with 3D vPCA in terms of suspected elevated ICP. Interrater reliability, sensitivity and specificity were assessed. RESULTS: Compression of venous sinuses was seen significantly more often in patients with shunt failure (p = 0.00003). Consequently, evaluation of 3D vPCA and T2-w images increases sensitivity to 0.92/1.0 compared to T2-w images alone with 0.69/0.77, the interrater agreement for the diagnosis of shunt failure rises from κ = 0.71 to κ = 0.837. Concerning imaging markers, three groups could be identified in children with shunt failure. CONCLUSION: In accordance with the literature, the results show that ventricular morphology alone is an unreliable marker for elevated ICP in children with shunt malfunction. The findings confirmed 3D vPCA as a valuable supplemental diagnostic tool improving diagnostic certainty for children with unchanged ventricular size in cases of shunt failure.


Assuntos
Hidrocefalia , Hipertensão Intracraniana , Humanos , Criança , Angiografia por Ressonância Magnética/métodos , Derivação Ventriculoperitoneal/efeitos adversos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Hidrocefalia/diagnóstico por imagem , Hidrocefalia/cirurgia
19.
Magn Reson Imaging Clin N Am ; 31(3): 413-431, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37414469

RESUMO

Magnetic resonance venography (MRV) represents a distinct imaging approach that may be used to evaluate a wide spectrum of venous pathology. Despite duplex ultrasound and computed tomography venography representing the dominant imaging modalities in investigating suspected venous disease, MRV is increasingly used due to its lack of ionizing radiation, unique ability to be performed without administration of intravenous contrast, and recent technical improvements resulting in improved sensitivity, image quality, and faster acquisition times. In this review, the authors discuss commonly used body and extremity MRV techniques, different clinical applications, and future directions.


Assuntos
Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Flebografia/métodos , Angiografia por Ressonância Magnética/métodos , Extremidades , Tomografia Computadorizada por Raios X
20.
Int J Cardiol ; 390: 131203, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37480997

RESUMO

OBJECTIVE: To compare the measurement of aortic diameters using a novel flow-independent MR-Angiography (3D modified Relaxation-Enhanced Angiography without Contrast and Triggering (modified REACT)) and transthoracic echocardiography (TTE) in Marfan syndrome (MFS) patients. MATERIAL AND METHODS: This retrospective, single-center analysis included 46 examinations of 32 MFS patients (mean age 37.5 ± 11.3 years, 17 women, no prior aortic surgery) who received TTE and 3D modified REACT (ECG- and respiratory-triggering, Compressed SENSE factor 9 for acceleration of image acquisition) of the thoracic aorta. Aortic diameters (sinus of Valsalva (SV), sinotubular junction (STJ), and ascending aorta (AoA)) were independently measured by two cardiologists in TTE (leading-edge) and two radiologists in modified REACT (inner-edge, using multiplanar reconstruction). Intraclass correlation coefficient, Bland-Altman analyses, and Pearson's correlation (r) were used to assess agreement between observers and methods. RESULTS: Interobserver correlation at the SV, STJ, and AoA were excellent for both, TTE (ICC = 0.95-0.98) and modified REACT (ICC = 0.99-1.00). There was no significant difference between TTE and modified REACT for diameters measured at the SV (39.24 ± 3.24 mm vs. 39.63 ± 3.76 mm; p = 0.26; r = 0.78) and the STJ (35.16 ± 4.47 mm vs. 35.37 ± 4.74 mm; p = 0.552; r = 0.87). AoA diameters determined by TTE were larger than in modified REACT (34.29 ± 5.31 mm vs. 30.65 ± 5.64 mm; p < 0.01; r = 0.74). The mean scan time of modified REACT was 05:06 min ± 02:47 min, depending on the patient's breathing frequency and heart rate. CONCLUSIONS: Both TTE and modified REACT showed a strong correlation for all aortic levels; however, at the AoA, diameters were larger using TTE, mostly due to the limited field of view of the latter with measurements being closer to the aortic valve. Given the excellent interobserver correlation and the strong agreement with TTE, modified REACT represents an attractive method to depict the thoracic aorta in MFS patients.


Assuntos
Aorta Torácica , Síndrome de Marfan , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Aorta Torácica/diagnóstico por imagem , Síndrome de Marfan/diagnóstico por imagem , Estudos Retrospectivos , Ecocardiografia/métodos , Angiografia por Ressonância Magnética/métodos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA