Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.561
Filtrar
Mais filtros











Intervalo de ano de publicação
2.
Chaos ; 34(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38526981

RESUMO

Malignant cardiac tachyarrhythmias are associated with complex spatiotemporal excitation of the heart. The termination of these life-threatening arrhythmias requires high-energy electrical shocks that have significant side effects, including tissue damage, excruciating pain, and worsening prognosis. This significant medical need has motivated the search for alternative approaches that mitigate the side effects, based on a comprehensive understanding of the nonlinear dynamics of the heart. Cardiac optogenetics enables the manipulation of cellular function using light, enhancing our understanding of nonlinear cardiac function and control. Here, we investigate the efficacy of optically resonant feedback pacing (ORFP) to terminate ventricular tachyarrhythmias using numerical simulations and experiments in transgenic Langendorff-perfused mouse hearts. We show that ORFP outperforms the termination efficacy of the optical single-pulse (OSP) approach. When using ORFP, the total energy required for arrhythmia termination, i.e., the energy summed over all pulses in the sequence, is 1 mJ. With a success rate of 50%, the energy per pulse is 40 times lower than with OSP with a pulse duration of 10 ms. We demonstrate that even at light intensities below the excitation threshold, ORFP enables the termination of arrhythmias by spatiotemporal modulation of excitability inducing spiral wave drift.


Assuntos
Arritmias Cardíacas , Optogenética , Animais , Camundongos , Retroalimentação , Arritmias Cardíacas/terapia , Coração , Luz , Potenciais de Ação
3.
Methodist Debakey Cardiovasc J ; 20(2): 36-50, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38495654

RESUMO

Cardiovascular disease significantly jeopardizes pregnancies in the United States, impacting 1% to 4% of pregnancies annually. Among complications, cardiac arrhythmias are prevalent, posing concerns for maternal and fetal health. The incidence of arrhythmias during pregnancy is rising, partly due to advances in congenital heart surgery and a growing population of women with structural heart disease. While most arrhythmias are benign, the increasing prevalence of more serious arrhythmias warrants a proactive approach. Guidance and reassurance suffice in many cases, but persistent symptoms require cautious use of antiarrhythmic drugs or other therapies for a safe outcome. Managing more serious arrhythmias requires a comprehensive, multidisciplinary approach involving specialists, including maternal-fetal medicine physicians, cardiologists, electrophysiologists, and anesthesiologists.


Assuntos
Antiarrítmicos , Arritmias Cardíacas , Gravidez , Feminino , Humanos , Estados Unidos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Antiarrítmicos/efeitos adversos
4.
Genes (Basel) ; 15(1)2024 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-38254962

RESUMO

Cardiac arrhythmias and sudden death are frequent in patients with non-ischemic cardiomyopathy and can precede heart failure or additional symptoms where malignant cardiac arrhythmias are mostly the consequence of advanced cardiomyopathy and heart failure. Finding these subgroups and making an early diagnosis could be lifesaving. In our retrospective study, we are presenting arrhythmic types of frequent cardiomyopathies where an arrhythmogenic substrate is less well defined, as in ischemic or structural heart disease. In the period of 2 years, next-generation sequencing (NGS) tests along with standard clinical tests were performed in 208 patients (67 women and 141 men; mean age, 51.2 ± 19.4 years) without ischemic or an overt structural heart disease after syncope or aborted sudden cardiac death. Genetic variants were detected in 34.4% of the study population, with a significant proportion of pathogenic variants (P) (14.4%) and variants of unknown significance (VUS) (20%). Regardless of genotype, all patients were stratified according to clinical guidelines for aggressive treatment of sudden cardiac death with an implantable cardioverter defibrillator (ICD). The P variant identified by NGS serves for an accurate diagnosis and, thus, better prevention and specific treatment of patients and their relatives. Results in our study suggest that targeted sequencing of genes associated with cardiovascular disease is an important addendum for final diagnosis, allowing the identification of a molecular genetic cause in a vast proportion of patients for a definitive diagnosis and a more specific way of treatment. VUS in this target population poses a high risk and should be considered possibly pathogenic in reanalysis.


Assuntos
Cardiopatias , Insuficiência Cardíaca , Masculino , Animais , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Síncope/diagnóstico , Síncope/genética , Sequenciamento de Nucleotídeos em Larga Escala , Morte Súbita Cardíaca/etiologia , Anuros , Arritmias Cardíacas/genética , Arritmias Cardíacas/terapia
5.
Circ J ; 88(5): 642-648, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38267052

RESUMO

BACKGROUND: Permanent pacemaker (PPM) implantation has been identified as a risk factor for morbidity and mortality after Fontan operation. This study investigated the factors associated with outcomes in patients with Fontan physiology who underwent PPM implantation.Methods and Results: We retrospectively reviewed 508 patients who underwent Fontan surgery at Asan Medical Center between September 1992 and August 2022. Of these patients, 37 (7.3%) received PPM implantation. Five patients were excluded, leaving 32 patients, of whom 11 were categorized into the poor outcome group. Poor outcomes comprised death, heart transplantation, and "Fontan failure". Clinical, Fontan procedure-related, and PPM-related factors were compared between the poor and good outcome groups. Ventricular morphology, Fontan procedure-associated factors, pacing mode, high ventricular pacing rate, and time from first arrhythmia to PPM implantation did not differ significantly between the 2 groups. However, the poor outcome group exhibited a significantly longer mean paced QRS duration (P=0.044). Receiver operating characteristic curve analysis revealed a paced QRS duration cut-off value of 153 ms with an area under the curve of 0.73 (P=0.035). CONCLUSIONS: A longer paced QRS duration was associated with poor outcomes, indicating its potential to predict adverse outcomes among Fontan patients.


Assuntos
Técnica de Fontan , Marca-Passo Artificial , Humanos , Técnica de Fontan/efeitos adversos , Técnica de Fontan/mortalidade , Estudos Retrospectivos , Masculino , Feminino , Criança , Pré-Escolar , Estimulação Cardíaca Artificial , Resultado do Tratamento , Adolescente , Fatores de Risco , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/fisiopatologia , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Arritmias Cardíacas/mortalidade , Fatores de Tempo , Adulto Jovem , Adulto
6.
J Cardiovasc Electrophysiol ; 35(3): 601-607, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38287171

RESUMO

The subcutaneous implantable cardioverter defibrillator (S-ICD) was developed as an alternative to the traditional transvenous implantable cardioverter defibrillator (TV-ICD), aiming to provide easier implantation, simplified detection algorithm of malignant ventricular arrhythmias and prevention from placing components in the cardiovascular system. The S-ICD is implanted subcutaneously or intramuscularly with the generator placed in the left midaxillary line and the lead tunneled subcutaneously in the left para-sternal region. Preimplant electrocardiogram screening is recommended to prevent implantation in patients at high risk of T wave over-sensing. Currently, the S-ICD is unsuitable for patients requiring pacing or cardiac resynchronization. Since the beginning, the S-ICD underwent extensive preclinical investigation until the first prospective multicentre trial demonstrating high efficacy and safety led to market release. While earlier studies focused on younger patients with higher ejection fraction, more recent studies showed favorable outcomes even in patients with comorbidities similar to those typically observed in patients receiving TV-ICD. The development of second and third generation devices has contributed to reduce inappropriate shocks and overcome previous limitations. The aim of this paper is to review the evidence in the literature over the past decade supporting S-ICD as a valid alternative to TV-ICD in terms of safety and efficacy, highlighting the improvements in technology, as well as outcomes.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Humanos , Morte Súbita Cardíaca/prevenção & controle , Estudos Prospectivos , Resultado do Tratamento , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Desfibriladores Implantáveis/efeitos adversos , Estudos Multicêntricos como Assunto
7.
Semin Cardiothorac Vasc Anesth ; 28(1): 38-46, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38284295

RESUMO

Since their initial approval by the Food and Drug Administration in 2016, leadless pacemakers have become increasingly prevalent. This growth has been driven by an improved adverse effect profile when compared to traditional pacemakers, including lower rates of infection, as well as eliminated risk of pocket hematoma and lead complications. More recently, technology enabling leadless synchronized atrioventricular pacing in patients with atrioventricular block has vastly expanded the indications for these devices. Anesthesiologists will increasingly be relied upon to safely care for patients with leadless pacemakers undergoing non-electrophysiology procedures and surgery. This article provides an overview of the technology, evidence base, current indications, and unique perioperative considerations for leadless pacemakers.


Assuntos
Marca-Passo Artificial , Humanos , Marca-Passo Artificial/efeitos adversos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Desenho de Equipamento
8.
Eur Heart J ; 45(7): 538-548, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38195003

RESUMO

BACKGROUND AND AIMS: Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death (SCD) in arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to identify cross-continental differences in utilization of primary prevention ICDs and survival free from sustained ventricular arrhythmia (VA) in ARVC. METHODS: This was a retrospective analysis of ARVC patients without prior VA enrolled in clinical registries from 11 countries throughout Europe and North America. Patients were classified according to whether they received treatment in North America or Europe and were further stratified by baseline predicted VA risk into low- (<10%/5 years), intermediate- (10%-25%/5 years), and high-risk (>25%/5 years) groups. Differences in ICD implantation and survival free from sustained VA events (including appropriate ICD therapy) were assessed. RESULTS: One thousand ninety-eight patients were followed for a median of 5.1 years; 554 (50.5%) received a primary prevention ICD, and 286 (26.0%) experienced a first VA event. After adjusting for baseline risk factors, North Americans were more than three times as likely to receive ICDs {hazard ratio (HR) 3.1 [95% confidence interval (CI) 2.5, 3.8]} but had only mildly increased risk for incident sustained VA [HR 1.4 (95% CI 1.1, 1.8)]. North Americans without ICDs were at higher risk for incident sustained VA [HR 2.1 (95% CI 1.3, 3.4)] than Europeans. CONCLUSIONS: North American ARVC patients were substantially more likely than Europeans to receive primary prevention ICDs across all arrhythmic risk strata. A lower rate of ICD implantation in Europe was not associated with a higher rate of VA events in those without ICDs.


Assuntos
Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/epidemiologia , Displasia Arritmogênica Ventricular Direita/terapia , Estudos Retrospectivos , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Fatores de Risco , América do Norte/epidemiologia , Europa (Continente)/epidemiologia
9.
Circ Genom Precis Med ; 17(1): e004305, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38288614

RESUMO

BACKGROUND: Pathogenic variants in PKP2 (plakophilin-2) cause arrhythmogenic right ventricular cardiomyopathy, a disease characterized by life-threatening arrhythmias and progressive cardiomyopathy leading to heart failure. No effective medical therapy is available to prevent or arrest the disease. We tested the hypothesis that adeno-associated virus vector-mediated delivery of the human PKP2 gene to an adult mammalian heart deficient in PKP2 can arrest disease progression and significantly prolong survival. METHODS: Experiments were performed using a PKP2-cKO (cardiac-specific, tamoxifen-activated PKP2 knockout murine model). The potential therapeutic, adeno-associated virus vector of serotype rh.74 (AAVrh.74)-PKP2a (PKP2 variant A; RP-A601) is a recombinant AAVrh.74 gene therapy viral vector encoding the human PKP2 variant A. AAVrh.74-PKP2a was delivered to adult mice by a single tail vein injection either before or after tamoxifen-activated PKP2-cKO. PKP2 expression was confirmed by molecular and histopathologic analyses. Cardiac function and disease progression were monitored by survival analyses, echocardiography, and electrocardiography. RESULTS: Consistent with prior findings, loss of PKP2 expression caused 100% mortality within 50 days after tamoxifen injection. In contrast, AAVrh.74-PKP2a-mediated PKP2a expression resulted in 100% survival for >5 months (at study termination). Echocardiographic analysis revealed that AAVrh.74-PKP2a prevented right ventricle dilation, arrested left ventricle functional decline, and mitigated arrhythmia burden. Molecular and histological analyses showed AAVrh.74-PKP2a-mediated transgene mRNA and protein expression and appropriate PKP2 localization at the cardiomyocyte intercalated disc. Importantly, the therapeutic benefit was shown in mice receiving AAVrh.74-PKP2a after disease onset. CONCLUSIONS: These preclinical data demonstrate the potential for AAVrh.74-PKP2a (RP-A601) as a therapeutic for PKP2-related arrhythmogenic right ventricular cardiomyopathy in both early and more advanced stages of the disease.


Assuntos
Displasia Arritmogênica Ventricular Direita , Adulto , Humanos , Camundongos , Animais , Displasia Arritmogênica Ventricular Direita/genética , Displasia Arritmogênica Ventricular Direita/terapia , Displasia Arritmogênica Ventricular Direita/metabolismo , Placofilinas/genética , Miócitos Cardíacos/metabolismo , Arritmias Cardíacas/genética , Arritmias Cardíacas/terapia , Arritmias Cardíacas/metabolismo , Tamoxifeno/metabolismo , Progressão da Doença , Mamíferos/metabolismo
10.
Medicine (Baltimore) ; 103(4): e37034, 2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38277551

RESUMO

RATIONALE: Digoxin is a frequently prescribed medication for the management of both acute and chronic cardiac insufficiency. The overdose ingestion of digoxin can result in a range of arrhythmias, with severe cases potentially leading to malignant arrhythmias and fatal outcomes. To date, there is a lack of documented cases related to acute digoxin intoxication resulting from the administration of massive digoxin overdose in the short term. PATIENT CONCERNS: A 37-year-old female patient was admitted to the emergency department following a suicide attempt involving the administration of 330 tablets of digoxin (each tablet containing 0.25 mg). The patient exhibited symptoms of confusion, nausea, and vomiting for around 30 minutes. The patient had a history of depression. DIAGNOSES: The patient was diagnosed with digoxin intoxication. INTERVENTIONS: The patient underwent many medical interventions including stomach lavage, administration of laxatives, correction of cardiac arrhythmias, provision of myocardial nutrition, diuresis, correction of acid-base balance, and management of electrolyte disturbances, among others. OUTCOMES: Following a treatment of 9 days, the patient exhibited no signs of discomfort, maintained consciousness, and the serum concentration of digoxin was indeterminable. Upon reevaluation of the electrocardiogram, it was determined that no arrhythmia was present. Consequently, the patient was authorized to be discharged from the hospital. CONCLUSIONS: There is currently no documented evidence of cases involving a significant overdose of digoxin resulting in intoxication. The patient had a comprehensive treatment regimen consisting of stomach lavage, administration of a laxative, correction of cardiac arrhythmias, provision of myocardial nutrition, fluid replacement, diuresis, and supportive therapy, resulting in successful outcomes. LESSONS: There have been no known cases of intoxication resulting from a significant overdose of digoxin, specifically with the consumption of 330 tablets (0.25 mg/tablet). However, in the event of ingesting excessive amounts of digoxin, it is imperative to promptly administer stomach lavage, administration of a laxative, and arrhythmia correction. The administration of temporary pacemaker therapy is recommended for patients presenting with high atrioventricular block, whereas hemoperfusion is advised for patients with renal insufficiency as a means to eliminate digoxin from the body.


Assuntos
Overdose de Drogas , Laxantes , Feminino , Humanos , Adulto , Digoxina , Overdose de Drogas/terapia , Arritmias Cardíacas/induzido quimicamente , Arritmias Cardíacas/terapia , Comprimidos
11.
Eur J Haematol ; 112(1): 102-110, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37649240

RESUMO

BACKGROUND: Cardiovascular events, including heart failure and arrhythmias, following chimeric antigen receptor (CAR) T-cell therapy are increasingly recognized. Although global longitudinal strain (GLS) has demonstrated prognostic utility for other cancer therapy-related cardiac dysfunction, less is known regarding the association of GLS with adverse cardiac events following CAR T-cell therapy. OBJECTIVES: To determine the association of baseline GLS with adverse cardiovascular events in adults receiving CAR-T cell therapy. METHODS: Patients who had an echocardiogram within 6 months prior to receiving CAR T-cell therapy were retrospectively identified. Clinical data and cardiac events were collected via chart review. Echocardiograms were analyzed offline for GLS, left ventricular ejection fraction, and Doppler parameters. Multivariable logistic regression was used to determine the association between adverse cardiovascular events and echocardiographic parameters. RESULTS: Among 75 CAR T-cell therapy patients (mean age 63.9, 34.7% female), nine patients (12%) experienced cardiac events (CEs) including cardiovascular death, new/worsening heart failure, and new/worsening arrhythmia within 1 year of treatment. In univariable models, higher baseline GLS (OR 0.78 [0.63, 0.96], p = .021) was associated with a lower risk of CE and higher baseline mitral E/e' (OR 1.40 [1.08, 1.81], p = .012) was associated with a higher risk of CE. After adjusting for age and LDH, higher baseline GLS (OR 0.65 [0.48-0.88], p = <.01) was associated with a lower risk of CE and higher baseline mitral E/e' (OR 1.56 [1.06, 2.29], p = .024) was associated with a higher risk of CE. CONCLUSION: Lower GLS and higher mitral E/e' on a baseline echocardiogram were associated with higher risk for CEs in patients receiving CAR T-cell therapy.


Assuntos
Insuficiência Cardíaca , Receptores de Antígenos Quiméricos , Disfunção Ventricular Esquerda , Adulto , Humanos , Feminino , Masculino , Função Ventricular Esquerda , Volume Sistólico/fisiologia , Estudos Retrospectivos , Imunoterapia Adotiva/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Terapia Baseada em Transplante de Células e Tecidos , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/terapia
12.
J Cardiovasc Transl Res ; 17(1): 91-101, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37556036

RESUMO

Implantable cardioverter defibrillators (ICDs) reduce sudden cardiac death (SCD) when patients experience life-threatening ventricular arrhythmias (LTVA). However, current strategies determining ICD patient selection and risk stratification are inefficient. We used metabolomics to assess whether dysregulated metabolites are associated with LTVA and identify potential biomarkers. Baseline plasma samples were collected from 72 patients receiving ICDs. Over a median follow-up of 524.0 days (range 239.0-705.5), LTVA occurred in 23 (31.9%) patients (22 effective ICD treatments and 1 SCD). After confounding risk factors adjustment for age, smoking, secondary prevention, and creatine kinase MB, 23 metabolites were significantly associated with LTVA. Pathway analysis revealed LTVA associations with disrupted metabolism of glycine, serine, threonine, and branched chain amino acids. Pathway enrichment analysis identified a panel of 6 metabolites that potentially predicted LTVA, with an area under the receiver operating characteristic curve of 0.8. Future studies are necessary on biological mechanisms and potential clinical use.


Assuntos
Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/complicações , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Resultado do Tratamento , Fatores de Risco
13.
Pediatr Cardiol ; 45(1): 63-67, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37740738

RESUMO

Sinus node dysfunction with concomitant junctional rhythm (JR) is frequently observed among Fontan patients and has been recognized as a contributor to heart failure. The impact and management of JR is unclear. A survey was mailed to all members of the Pediatric and Congenital Electrophysiology society (PACES) and members were asked to forward the questionnaire to their non-electrophysiology colleagues. Responses were received from 154 physicians (88 electrophysiologists (EP's) and 66 non-EP's (46 pediatric cardiologists and 20 adult congenital cardiologists). There were few differences in the response between EP's and non-EP's. Overall, 57% recommended an annual ambulatory ECG (AECG). A significant majority (80%) opted to continue to follow patients with significant periods of JR on AECG as long as the patients were asymptomatic, and showed no echocardiographic signs of cardiac decompensation. However, 84% would place a pacemaker in a patient with JR who was having open chest surgery for other reasons. Finally, pacemaker placement would be performed by 91% if a patient with JR showed signs of heart failure. Most congenital cardiologists would not recommend pacemaker placement in asymptomatic Fontan patients with JR. Further studies are needed on the Fontan population to determine the impact of SND and JR on longer term outcomes and to determine the role and optimal timing of pacemaker placement in these patients.


Assuntos
Cardiologia , Técnica de Fontan , Cardiopatias Congênitas , Insuficiência Cardíaca , Adulto , Criança , Humanos , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/complicações , Arritmias Cardíacas/terapia , Arritmias Cardíacas/complicações , Inquéritos e Questionários , Insuficiência Cardíaca/complicações
14.
J Intensive Care Med ; 39(2): 99-117, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37731333

RESUMO

Electrical storm (ES) is characterized by three or more discrete sustained ventricular tachyarrhythmia episodes occurring within a limited time frame (generally ≤ 24 h) or an incessant ventricular tachyarrhythmia lasting > 12 h. In patients with an implantable cardioverterdefibrillator (ICD), ES is defined as three or more appropriate device therapies, separated from each other by at least 5 min, which occur within a 24-h period. ES may constitute a medical emergency, depending on the number arrhythmic episodes, their duration, the type, and the cycle length of the ventricular arrhythmias, as well as the underlying ventricular function. This narrative review was facilitated by a search of MEDLINE to identify peer-reviewed clinical trials, randomized controlled trials, meta-analyses, and other clinically relevant studies. The search was limited to English-language reports published between 1999 and 2023. ES was searched using the terms mechanisms, genetics, channelopathies, management, pharmacological therapy, sedation, neuraxial modulation, cardiac sympathetic denervation, ICDs, and structural heart disease. Google and Google scholar as well as bibliographies of identified articles were reviewed for additional references. This manuscript examines the current strategies available to treat ES and compares pharmacological and invasive treatment strategies to diminish ES recurrence, morbidity, and mortality.


Assuntos
Desfibriladores Implantáveis , Cardiopatias , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia
15.
EBioMedicine ; 99: 104937, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38118401

RESUMO

BACKGROUND: Risk stratification for ventricular arrhythmias currently relies on static measurements that fail to adequately capture dynamic interactions between arrhythmic substrate and triggers over time. We trained and internally validated a dynamic machine learning (ML) model and neural network that extracted features from longitudinally collected electrocardiograms (ECG), and used these to predict the risk of malignant ventricular arrhythmias. METHODS: A multicentre study in patients implanted with an implantable cardioverter-defibrillator (ICD) between 2007 and 2021 in two academic hospitals was performed. Variational autoencoders (VAEs), which combine neural networks with variational inference principles, and can learn patterns and structure in data without explicit labelling, were trained to encode the mean ECG waveforms from the limb leads into 16 variables. Supervised dynamic ML models using these latent ECG representations and clinical baseline information were trained to predict malignant ventricular arrhythmias treated by the ICD. Model performance was evaluated on a hold-out set, using time-dependent receiver operating characteristic (ROC) and calibration curves. FINDINGS: 2942 patients (61.7 ± 13.9 years, 25.5% female) were included, with a total of 32,129 ECG recordings during a mean follow-up of 43.9 ± 35.9 months. The mean time-varying area under the ROC curve for the dynamic model was 0.738 ± 0.07, compared to 0.639 ± 0.03 for a static (i.e. baseline-only model). Feature analyses indicated dynamic changes in latent ECG representations, particularly those affecting the T-wave morphology, were of highest importance for model predictions. INTERPRETATION: Dynamic ML models and neural networks effectively leverage routinely collected longitudinal ECG recordings for personalised and updated predictions of malignant ventricular arrhythmias, outperforming static models. FUNDING: This publication is part of the project DEEP RISK ICD (with project number 452019308) of the research programme Rubicon which is (partly) financed by the Dutch Research Council (NWO). This research is partly funded by the Amsterdam Cardiovascular Sciences (personal grant F.V.Y.T).


Assuntos
Desfibriladores Implantáveis , Humanos , Feminino , Masculino , Morte Súbita Cardíaca , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Eletrocardiografia , Redes Neurais de Computação
16.
Heart Rhythm ; 21(4): 419-426, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38142831

RESUMO

BACKGROUND: Left bundle branch pacing (LBBP) has been suggested as an alternative modality for biventricular pacing in cardiac resynchronization therapy (CRT)-eligible patients. As it provides stable R-wave sensing, LBBP has been recently used to provide sensing of ventricular arrhythmia in patients receiving implantable cardioverter-defibrillator (ICD) with CRT. OBJECTIVE: The aim of this study was to analyze the long-term safety and efficacy of the LBBP lead for appropriate detection of ventricular arrhythmia and delivery of antitachycardia pacing (ATP) in patients requiring defibrillator therapy with CRT. METHODS: CRT-eligible patients who underwent successful LBBP-optimized ICD and LBBP-optimized CRT with defibrillator were enrolled. The LBBP lead was connected to the right ventricular-P/S port after capping the IS-1 connector plug of the DF-1-ICD lead. LBBP-optimized ICD or LBBP-optimized CRT with defibrillator was decided on the basis of correction of conduction system disease. Documented arrhythmic episodes and therapy delivered were analyzed. RESULTS: Thirty patients were enrolled. The mean age was 59.7 ± 10.5 years. LBBP resulted in an increase in left ventricular ejection fraction from 29.9% ± 4.6% to 43.9% ± 11.2% (P < .0001). During a mean follow-up of 22.9 ± 12.5 months, 254 ventricular arrhythmic events were documented. Appropriate events (n = 225 [89%]) included nonsustained ventricular tachycardia (VT) (n = 212 episodes [94%]), VT (n = 8 [3.5%]), and ventricular fibrillation (n = 5 [2.5%]). ATP efficacy in terminating VT was 75%. Eleven percent of episodes (n = 29) were inappropriately detected because of T-wave oversensing. Inappropriate therapy (ATP) was delivered for 14 episodes (5.5%). Three patients (10%) had worsening of tricuspid regurgitation. CONCLUSION: Sensing from the LBBP lead for arrhythmia detection is safe as ∼90% of the episodes were detected appropriately. Future studies with a dedicated LBBP-defibrillator lead along with algorithms to avoid oversensing can help in combining defibrillation with conduction system pacing.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Humanos , Pessoa de Meia-Idade , Idoso , Projetos Piloto , Desfibriladores Implantáveis/efeitos adversos , Volume Sistólico , Função Ventricular Esquerda , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Doença do Sistema de Condução Cardíaco , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Trifosfato de Adenosina , Resultado do Tratamento
17.
Hum Gene Ther ; 35(3-4): 114-122, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38131291

RESUMO

The cardiac autonomic nervous system (CANS) is intimately connected to the regulation of electrophysiology and arrhythmogenesis in cardiac systems. This work aimed at investigating whether interleukin-10 (IL-10) could effectively modulate CANS and suppress ischemia-induced ventricular arrhythmia (VA) through chronically acting on the cardiac sympathetic ganglion (CSG). Using an adeno-associated virus (AAV), we achieved local chronic overproduction of IL-10 in the CSG, left stellate ganglion (LSG). As a result, in the IL-10 group, we observed a decreased number of tyrosine hydroxylase-positive (TH+) cells in the LSG. IL-10 markedly downregulated the nerve growth factor, synaptophysin, as well as growth-associated protein 43 expression. In vivo, results from ambulatory electrocardiography showed that IL-10 overexpression significantly inhibited the cardiac sympathetic nervous system activity and improved heart rate variability. Meanwhile, we observed decreased LSG function as well as prolonged ventricular effective refractory period and suppressed VA after myocardial infarction (MI) in the IL-10 group. In addition, IL-10 overexpression attenuated inflammation and decreased norepinephrine levels in the myocardium after acute MI. In conclusion, our data suggest that chronic IL-10 overexpression modulates cardiac sympathetic nerve remodeling and suppresses VA induced by MI. Neuromodulation through AAV-mediated IL-10 overexpression may have the characteristics of and advantages as a potential neuroimmunotherapy for preventing MI-induced VAs.


Assuntos
Interleucina-10 , Infarto do Miocárdio , Animais , Interleucina-10/genética , Interleucina-10/metabolismo , Coração , Arritmias Cardíacas/genética , Arritmias Cardíacas/terapia , Arritmias Cardíacas/metabolismo , Infarto do Miocárdio/metabolismo , Gânglio Estrelado/metabolismo , Transgenes , Modelos Animais de Doenças
18.
J Med Case Rep ; 17(1): 554, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38129927

RESUMO

BACKGROUND: We report a case of a clinical challenge lasting for 12 months, with severe and unresolved clinical features involving several medical disciplines. CASE PRESENTATION: A 53-year-old Caucasian male, who had been previously healthy apart from a moderate renal impairment, was hospitalized 12 times during a 1-year period for a recurrent complex of neurological, cardiovascular, and gastrointestinal symptoms and signs, without any apparent etiology. On two occasions, he suffered a cardiac arrest and was successfully resuscitated. Following the first cardiac arrest, a cardiac defibrillator was inserted. During the 12th admission to our hospital, aconitine poisoning was suspected after a comprehensive multidisciplinary evaluation and confirmed by serum and urine analyses. Later, aconitine was also detected in a hair segment, indicating exposure within the symptomatic period. After the diagnosis was made, no further episodes occurred. His cardiac defibrillator was later removed, and he returned to work. A former diagnosis of epilepsy was also abandoned. Criminal intent was suspected, and his wife was sentenced to 11 years in prison for attempted murder. To make standardized assessments of the probability for aconitine poisoning as the cause of the eleven prior admissions, an "aconitine score" was established. The score is based on neurological, cardiovascular, gastrointestinal, and other clinical features reported in the literature. We also make a case for the use of hair analysis to confirm suspected poisoning cases evaluated after the resolution of clinical features. CONCLUSION: This report illustrates the medical challenge raised by cases of covert poisoning. In patients presenting with symptoms and signs from several organ systems without apparent cause, poisoning should always be suspected. To solve such cases, insight into the effects of specific toxic agents is needed. We present an "aconitine score" that may be useful in cases of suspected aconitine poisoning.


Assuntos
Aconitina , Arritmias Cardíacas , Parada Cardíaca , Parestesia , Humanos , Masculino , Pessoa de Meia-Idade , Aconitina/intoxicação , Arritmias Cardíacas/induzido quimicamente , Arritmias Cardíacas/terapia , Coração , Parada Cardíaca/induzido quimicamente , Parada Cardíaca/terapia , População Branca
19.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37935403

RESUMO

Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a heritable cardiomyopathy characterized by a predominantly arrhythmic presentation. It represents the leading cause of sudden cardiac death (SCD) among athletes and poses a significant morbidity threat in the general population. As a causative treatment for ARVC is still not available, the placement of an implantable cardioverter defibrillator represents the current cornerstone for SCD prevention in this setting. Thanks to international ARVC-dedicated efforts, significant steps have been achieved in recent years towards an individualized, patient-centred risk stratification approach. A novel risk calculator algorithm estimating the 5-year risk of arrhythmias of patients with ARVC has been introduced in clinical practice and subsequently validated. The purpose of this article is to summarize the body of evidence that has allowed the development of this tool and to discuss the best way to implement its use in the care of an individual patient.


Assuntos
Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis , Humanos , Fatores de Risco , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/terapia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/epidemiologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/complicações , Desfibriladores Implantáveis/efeitos adversos , Medição de Risco
20.
BMC Cardiovasc Disord ; 23(1): 518, 2023 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-37875800

RESUMO

BACKGROUND: Cannabis is the most consumed drug worldwide and number of users is increasing, particularly among youth. Moreover, cannabis potential therapeutic properties have renewed interest to make it available as a treatment for a variety of conditions. Albeit rarely, cannabis consumption has been associated with cardiovascular diseases such as arrhythmias, myocardial infarction (MI) and potentially sudden death. CASE PRESENTATION: A 24-year-old woman presented to the emergency department sent by her cardiologist because of a recent finding of a 16 seconds asystole on the implantable loop recorder (ILR) she implanted 7 months before for recurrent syncopes. She declared that she is a heavy cannabis user (at least 5 cannabis-cigarette per day, not mixed up with tobacco, for no less than 12 years) and all syncopes occurred shortly after cannabis consumption. After a collective discussion with the heart team, syncope unit, electrophysiologists and toxicologist, we decided to implant a dual chamber pacemaker with a rate response algorithm due to the high risk of trauma of the syncopal episodes. 24 months follow-up period was uneventful. CONCLUSIONS: Cannabis cardiovascular effects are not well known and, although rare, among these we find ischemic episodes, tachyarrhythmias, symptomatic sinus bradycardia, sinus arrest, ventricular asystole and possibly death. Because of cannabis growing consumption both for medical and recreational purpose, cardiovascular diseases associated with cannabis use may become more and more frequent. In the light of the poor literature, we believe that cannabis may produce opposite adverse effects depending on the duration of the habit. Acute administration increases sympathetic tone and reduces parasympathetic tone; conversely, with chronic intake an opposite effect is observed: repetitive dosing decreases sympathetic activity and increases parasympathetic activity. Clinicians should be aware of the increased risk of cardiovascular complications associated with cannabis use and should investigate its consumption especially in young patients presenting with cardiac dysrhythmias.


Assuntos
Cannabis , Parada Cardíaca , Marca-Passo Artificial , Feminino , Humanos , Adulto Jovem , Arritmias Cardíacas/terapia , Cannabis/efeitos adversos , Eletrocardiografia Ambulatorial , Parada Cardíaca/terapia , Síncope/etiologia
SELEÇÃO DE REFERÊNCIAS