Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.615
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Innovations (Phila) ; 19(2): 192-195, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38606852

RESUMO

OBJECTIVE: Femoral artery cannulation is the most commonly used approach for cardiopulmonary bypass (CPB) in robotic cardiac procedures. However, without adding a distal perfusion cannula, leg ischemia can occur in up to 11.5% of patients. There is a well-described 2 to 4 mm size arterial branch that originates from the medial side of the external iliac artery or inferior epigastric artery, immediately above the inguinal ligament, and connects to the obturator artery. Therefore, it was historically named the corona mortis, which means "crown of death" in Latin. When peripheral cannulation is performed above this branch in the external iliac artery, we consider it a corona "vitae" because of its role as a limb-saving collateral. We report herein our standard technique of peripheral cannulation without the need of a distal perfusion cannula and preventing limb ischemia. METHODS: We included all patients who underwent robotic cardiac surgery with peripheral cannulation over a 16-month period at our institution. We cannulated just above the level of the inguinal ligament through a 2 to 3 cm transverse skin incision. The incidence of limb ischemia and vascular complications was recorded and analyzed. RESULTS: During the study period, 133 patients underwent robotic cardiac procedures with peripheral "external iliac" CPB. The size of the cannula was 21F or larger in 73% and 23F in 54% of the patients. No leg ischemia or femoral artery complications requiring additional intervention occurred. CONCLUSIONS: External iliac cannulation can be successfully performed in robot-assisted cardiac surgery using relatively large cannulas without the need of a distal limb perfusion catheter, with good results. In our view, given the importance of the corona mortis ("crown of death" in Latin) in perfusing the limb during CPB, we propose a new name for this artery in robotic cardiac surgery, namely, the corona vitae ("crown of life" in Latin).


Assuntos
Artéria Ilíaca , Procedimentos Cirúrgicos Robóticos , Humanos , Artéria Ilíaca/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Masculino , Feminino , Idoso , Procedimentos Cirúrgicos Cardíacos/métodos , Ponte Cardiopulmonar/métodos , Pessoa de Meia-Idade , Isquemia/prevenção & controle , Cateterismo Periférico/métodos , Artéria Femoral/cirurgia , Cateterismo/métodos
2.
BMJ Case Rep ; 17(4)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589247

RESUMO

Corona mortis (CM) is an anastomotic vessel between the inferior epigastric or external iliac vessels and the obturator or internal iliac vessels. The Latin meaning of it is 'crown of death' which corresponds to massive haemorrhage caused by injury to this vessel during surgery. The incidence of this vessel is around 50% in the hemipelvis. We are presenting an intraoperative video of a right laparoscopic totally extraperitoneal mesh hernioplasty demonstrating a CM artery in the right hemipelvis. Care was taken to prevent injury to this vessel. CO2 insufflation pressure was reduced to less than 10 mm Hg to see any venous variant of this vessel. Carefully, polypropylene mesh was placed without a fixation device. Anatomical knowledge of the CM vessel is therefore essential in preventing injury for surgeons who approach the inguinal and retropubic regions.


Assuntos
Hérnia Inguinal , Laparoscopia , Humanos , Artéria Ilíaca/cirurgia , Herniorrafia , Telas Cirúrgicas/efeitos adversos , Artérias/cirurgia , Hérnia Inguinal/cirurgia
3.
Medicine (Baltimore) ; 103(14): e37731, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38579061

RESUMO

RATIONALE: A hostile iliac access route is an important consideration when enforcing endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA). Herein, we report a case of AAA with unilateral external iliac artery occlusion, for which bifurcated EVAR was successfully performed using a single femoral and brachial artery access. PATIENT CONCERNS: A 76-year-old man who had undergone surgery for lung cancer 4.5 years prior was diagnosed AAA by computed tomography (CT). DIAGNOSIS: Two and a half years before presentation, CT revealed an infrarenal 48 mm AAA, which had enlarged to 57 mm by 2 months preoperatively. CT identified occlusion from the right external iliac artery to the right common femoral artery, with no observed ischemic symptoms in his right leg. The right external iliac artery, occluded and atrophied, had a 1 to 2 mm diameter. INTERVENTION: Surgery was commenced with the selection of a Zenith endovascular graft (Cook Medical) with an extended body length. Two Gore Viabahn VBX balloon expandable endoprosthesis (VBX; W.L. Gore & Associate) were delivered from the right axilla as the contralateral leg. OUTCOMES: CT scan on the 2nd day after surgery revealed no endoleaks. LESSONS: While the long-term results remain uncertain, this method may serve as an option for EVAR in patients with unilateral external iliac artery occlusion.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco , Masculino , Humanos , Idoso , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Implante de Prótese Vascular/métodos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Axila/cirurgia , Perna (Membro)/cirurgia , Procedimentos Endovasculares/métodos , Stents , Resultado do Tratamento , Aneurisma Ilíaco/cirurgia
4.
J Cardiovasc Surg (Torino) ; 65(2): 85-98, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38635284

RESUMO

Endovascular aortic repair (EVAR) is nowadays the establishment treatment for patients with abdominal aortic aneurysm (AAA) both in elective and urgent setting. Despite the large applicability and satisfactory results, the presence of hostile iliac anatomy affects both technical and clinical success. This narrative review aimed to report the impact of iliac access and related adjunctive procedures in patients undergoing EVAR in elective and non-elective setting. Hostile iliac access can be defined in presence of narrowed, tortuous, calcified, or occluded iliac arteries. These iliac characteristics can be graded by the anatomic severity grade score to quantitatively assess anatomic complexity before undergoing treatment. Literature shows that iliac hostility has an impact on device navigability, insertion and perioperative and postoperative results. Overall, it has been correlated to higher rate of access issues, representing up to 30% of the first published EVAR experience. Recent innovations with low-profile endografts have reduced large-bore sheaths related issues. However, iliac-related complications still represent an issue, and several adjunctive endovascular and surgical strategies are nowadays available to overcome these complications during EVAR. In urgent settings iliac hostility can significantly impact on particular time sensitive procedures. Moreover, in case of severe hostility patients might be written off for EVAR repair might be inapplicable, exposing to higher mortality/morbidity risk in this urgent/emergent setting. In conclusion, an accurate anatomical evaluation of iliac arteries during preoperative planning, materials availability, and skilled preparation to face iliac-related issues are crucial to address these challenges.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Cirúrgicos Eletivos , Procedimentos Endovasculares , Artéria Ilíaca , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Artéria Ilíaca/cirurgia , Artéria Ilíaca/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Resultado do Tratamento , Fatores de Risco , Prótese Vascular , Complicações Pós-Operatórias/etiologia
6.
Microsurgery ; 44(4): e31171, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38549389

RESUMO

BACKGROUND: With the growing demand for the use of thin perforator flaps, obtaining knowledge on the superficial anatomy of perforators is imperative for stable flap elevation. Conventional modalities for perforator mapping fall short in providing such information. High-frequency ultrasound (HFUS), known for visualizing the superficially located anatomic structures, may potentially fill this void. This study aimed to evaluate the effectiveness of HFUS in the outcome of anterolateral thigh (ALT) and superficial circumflex iliac artery perforator (SCIP) flap-based reconstructions. METHODS: Consecutive patients who underwent free ALT or SCIP flap-based reconstruction from January 2021 to November 2022 were retrospectively reviewed. Perforator mapping was conducted using a handheld Doppler during the first year, while HFUS was used in the latter part. The two techniques were compared in terms of flap harvesting time and perfusion-related complication rates while considering the flap elevation plane. RESULTS: In total, 123 cases were analyzed, including 82 ALT flaps (41 in each group) and 41 SCIP flaps (16 in the Doppler and 25 in the HFUS group). The time required for flap elevation exhibited a tendency to decrease in the HFUS group, with a significant difference observed in cases involving thin flap elevation (super-thin ALT flaps and pure-skin-perforator SCIP flaps). Compared with the Doppler group, the HFUS group demonstrated significantly lower rates of PRCs, particularly partial flap necrosis. This difference remained significant in multivariable analyses. CONCLUSION: Our results suggest that HFUS might be an appealing modality for perforator mapping in cases requiring thin ALT and SCIP flap.


Assuntos
Retalho Perfurante , Procedimentos de Cirurgia Plástica , Humanos , Retalho Perfurante/irrigação sanguínea , Coxa da Perna/cirurgia , Coxa da Perna/irrigação sanguínea , Artéria Ilíaca/cirurgia , Estudos Retrospectivos
7.
Hand Clin ; 40(2): 179-187, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38553089

RESUMO

The superficial circumflex iliac artery perforator (SCIP) flap is thin, pliable tissue well suited for reconstruction of injuries of the hand and upper extremity. Based upon perforators from the superficial circumflex iliac artery, the SCIP flap has advantages over the traditional groin flap due to reduced need for secondary procedures and improved donor site morbidity This article offers a detailed exploration of the SCIP flap design and technique, its advantages over traditional methods, and its potential applications in reconstructive surgery. Post-operative care and critical points are also discussed, and case examples are provided to guide readers through the intricacies of the technique, emphasizing the surgical skill and precision required for successful implementation.


Assuntos
Retalho Perfurante , Procedimentos de Cirurgia Plástica , Humanos , Retalho Perfurante/irrigação sanguínea , Artéria Ilíaca/cirurgia , Extremidade Superior/cirurgia , Mãos/cirurgia
8.
Khirurgiia (Mosk) ; (3): 21-28, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38477240

RESUMO

OBJECTIVE: To compare the short-term and long-term outcomes of hybrid interventions after various infrainguinal reconstructions (restoration of blood flow through superficial femoral artery and pulsatile blood flow through deep femoral artery) in patients with iliac-femoral arterial disease. MATERIAL AND METHODS: A retrospective analysis included patients after hybrid iliac-femoral interventions between 2014 and 2018. These interventions included stenting of iliac arteries and various open infrainguinal reconstructions. The first group (n=41) consisted of patients who underwent reconstruction of superficial femoral artery, the second group (n=88) - restoration of pulsatile blood flow in deep femoral artery. We analyzed the Rutherford score, perioperative complications, primary patency rates and limb salvage rates after 12 months in both groups. RESULTS: Significant improvement (Rutherford score +3) was achieved in 28 (70%) and 14 (15.9%) patients, respectively (p<0.05). There were no significant between-group differences in the number of postoperative complications. Surgery time was longer in the first group (median 160 and 130 min, respectively, p<0.05). However, intraoperative blood loss was similar. Primary patency rates after 12 months were 82.4% and 95.1%, respectively (p=0.054). Limb salvage rates after 12 months were 94.7% and 100%, respectively (p<0.05). CONCLUSION: This study highlights the potential advantages of restoring pulsatile blood flow through the deep femoral artery in hybrid interventions. Higher primary patency and limb salvage rates in the second group indicate better long-term outcomes after restoration of blood flow through the deep femoral artery. Further prospective studies are needed to confirm these results and determine the underlying mechanisms of differences.


Assuntos
Arteriopatias Oclusivas , Artéria Femoral , Humanos , Estudos Retrospectivos , Grau de Desobstrução Vascular , Artéria Femoral/cirurgia , Artéria Ilíaca/cirurgia , Salvamento de Membro , Stents , Resultado do Tratamento , Arteriopatias Oclusivas/cirurgia , Fatores de Risco
9.
Head Neck ; 46(6): 1428-1438, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38533771

RESUMO

BACKGROUND: Head and neck tissue defects after ablative surgery often require complex and composite reconstructions. The superficial circumflex iliac artery perforator (SCIP) flap is an extremely versatile perforator-based flap with minimal donor site morbidity, which may represent the optimal procedure in this setting. Over the last 5 years, we collected a large base of experience, including both simple and chimeric SCIP-based reconstruction, making this flap our first choice for head and neck reconstructions. PATIENTS AND METHODS: Seventy-three patients undergoing ablative head and neck surgery for oncologic pathologies were treated by means of a SCIP flap reconstruction. Patients' mean age was 67 years old (range 37-89), 51 were males and 22 were females. Fifty-eight flaps were simple and 15 were chimeric reconstruction patterns. Indocyanine green perfusion imaging was performed in all cases. RESULTS: All the patients were successfully treated with no flap losses were encountered. Twelve patients encountered postoperative complications: in four cases revision surgery was required for venous congestion, while the remaining cases were managed conservatively (four wound dehiscence and three infections). No patients showed donor site complications. The mean follow-up period was 11 months (range 3-24). CONCLUSIONS: Our case series demonstrates the reliability and versatility of the SCIP flap for different kinds of head and neck reconstructions. The chimeric options combined with bone, double skin paddle, and muscle offer a broad variety of functional reconstructive solutions for complex head and neck surgeries. Intraoperative indocyanine green perfusion examination provides a valuable tool to assess and ascertain proper vascularization and post-anastomosis vessel patency in complex microvascular flap-based reconstructions.


Assuntos
Neoplasias de Cabeça e Pescoço , Artéria Ilíaca , Retalho Perfurante , Procedimentos de Cirurgia Plástica , Humanos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Procedimentos de Cirurgia Plástica/métodos , Neoplasias de Cabeça e Pescoço/cirurgia , Adulto , Idoso de 80 Anos ou mais , Retalho Perfurante/irrigação sanguínea , Artéria Ilíaca/cirurgia , Resultado do Tratamento , Retalhos de Tecido Biológico/irrigação sanguínea , Estudos Retrospectivos
10.
Am J Case Rep ; 25: e942727, 2024 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-38341610

RESUMO

BACKGROUND Managing IgG4-related disease (IgG4-RD) in the context of vascular complications, such as aneurysms, poses significant challenges, particularly when considering surgical intervention options. The risk of rupture and infection in patients on long-term glucocorticoid therapy complicates treatment decisions. CASE REPORT A 63-year-old woman with a history of IgG4-RD presented with a ruptured right iliac artery aneurysm. She was on long-term oral glucocorticoid therapy. Initial emergency endovascular stent graft implantation was followed by embolization for suspected arterial bleeding and subsequent Salmonella bacteremia. Repeated hospitalizations involved stent graft removal and surgical repair due to persistent infection. Over 2 years, the patient required multiple pelvic drainages and long-term antibiotic and prednisolone therapy, yet her quality of life remained compromised. CONCLUSIONS Our case highlights the unique challenges and considerations in the treatment of IgG4-related aneurysms. Patients with IgG4-RD who are on long-term oral glucocorticoids have an inherent risk of aneurysm rupture. We believe regular follow-ups to monitor the progression of the aorta and iliac arteries into aneurysms are essential. For patients who have developed aneurysms, it is advisable to reduce the dosage of glucocorticoids or even consider surgical treatment as soon as possible. As for the choice of surgical method, there is no consensus yet. While endovascular treatment is less invasive and quicker, it can increase the risk of rupture and bleeding. Open surgery might be a better option. More data are needed to make a definitive judgment.


Assuntos
Aneurisma Roto , Aneurisma Ilíaco , Doença Relacionada a Imunoglobulina G4 , Feminino , Humanos , Pessoa de Meia-Idade , Aneurisma Roto/complicações , Aneurisma Roto/cirurgia , Glucocorticoides/efeitos adversos , Aneurisma Ilíaco/complicações , Aneurisma Ilíaco/cirurgia , Artéria Ilíaca/cirurgia , Doença Relacionada a Imunoglobulina G4/complicações , Doença Relacionada a Imunoglobulina G4/cirurgia , Qualidade de Vida , Stents , Resultado do Tratamento
11.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38321257

RESUMO

Anomalous left coronary artery originating from the pulmonary artery (ALCAPA) is an infrequent congenital anomaly. Presentation of this syndrome is rare in adults. Nevertheless, adult patients are at risk of ischaemia, arrhythmias or sudden cardiac death and always require surgical intervention. At our institution, a specific technique of interposition of the right internal iliac artery as a free-graft for left coronary artery reimplantation was used in adult ALCAPA patients. The aim of this report is to determine long-term results and experiences with this surgical technique.


Assuntos
Artéria Coronária Esquerda Anormal , Síndrome de Bland-White-Garland , Anomalias dos Vasos Coronários , Adulto , Humanos , Síndrome de Bland-White-Garland/cirurgia , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Artéria Pulmonar/anormalidades , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Reimplante , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/cirurgia
13.
Ann Vasc Surg ; 103: 31-37, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38301852

RESUMO

BACKGROUND: To evaluate the short-term and mid-term safety and efficacy of stent-graft compared with bare stents for treatment of aortoiliac occlusive disease (AIOD). METHODS: One hundred eighty three patients diagnosed with AIOD who received stent implantation at 3 vascular centers in north China between January 2019 and December 2021 were enrolled. Patients were divided into those undergoing stent-graft (Group A; n = 67) or bare stent (Group B; n = 116) implantation for retrospective cohort analysis. Efficacy was assessed as surgical success rate and rate of freedom from clinically driven target lesion reintervention at each follow-up time point. Safety was assessed by the rate of perioperative complication, major limb amputation, and aortoiliac artery-related mortality. RESULTS: There were no preoperative baseline differences between the 2 groups (P > 0.05). The surgical success was 91.04% for Group A, significantly higher than that for Group B (79.31%; P < 0.05). Incidence of perioperative complications was 2.98% for Group A, significantly lower than that for Group B (9.48%, P < 0.05), as was the rate of major limb amputation (A: 1.49% vs. B: 5.17%) and aortoiliac artery-related mortality (A: 1.49% vs. B: 4.31%), although these 2 indicators were not significantly different (P > 0.05). Follow-up rates were 91.8% for the total follow-up time of 3 years. Kaplan-Meier survival curve analysis gave significantly higher 1-year and 2-year freedom from clinically driven target lesion reintervention for Group A (98.51% and 95.52%) than for Group B (95.69% and 89.66%, P < 0.05). CONCLUSIONS: Stent-graft is more effective and safer than bare stent in the treatment of AIOD.


Assuntos
Amputação Cirúrgica , Doenças da Aorta , Arteriopatias Oclusivas , Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Artéria Ilíaca , Stents , Grau de Desobstrução Vascular , Humanos , Masculino , Feminino , Artéria Ilíaca/cirurgia , Artéria Ilíaca/diagnóstico por imagem , Estudos Retrospectivos , Pessoa de Meia-Idade , Fatores de Tempo , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Idoso , Doenças da Aorta/cirurgia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/mortalidade , Arteriopatias Oclusivas/cirurgia , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/mortalidade , China , Resultado do Tratamento , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Fatores de Risco , Salvamento de Membro , Desenho de Prótese , Complicações Pós-Operatórias/etiologia , Medição de Risco
14.
Microsurgery ; 44(2): e31138, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38343009

RESUMO

Following its initial description by Koshima in 2004, the superficial circumflex iliac artery perforator (SCIP) flap has become a ubiquitous and extremely useful flap in coverage of defects whereby bulkiness must be avoided. It also allows direct closure and concealment of the donor site. Its use as a free tissue transfer has been demonstrated by various surgeons globally. Nevertheless, there are few cases illustrating the utility of the pedicled SCIP flap in the reconstruction of lower abdominal defects. We present a case of a pedicled SCIP flap utilized as a chimeric flap incorporating external oblique muscle fascia on a deep branch along with the typical fasciocutaneous component based on the superficial branch to cover the suprapubic defect after vesicocutaneous fistula repair. We thereafter report on the literature of pedicled chimeric SCIP flap for locoregional reconstruction. A 26-year-old female was referred to the Plastic and Reconstructive Surgery unit after suffering a functional bladder outlet obstruction necessitating the creation of a urinary stoma. Subsequently, stoma obstruction occurred, and a suprapubic catheter was performed that was complicated by infection and resulted in the development of a vesicocutaneous fistula. Accordingly, the urological surgeons were planning surgical closure of the suprapubic vesicocutaneous defect, measuring 5 × 4 cm. A pedicled SCIP flap was designed to match the defect size; and raised as a chimeric flap with external oblique muscle fascia based on the deep branch, along with the fasciocutaneous component based on the superficial branch. The external oblique fascial component was used to secure the suture line of fistula repair, over which the fasciocutaneous component was inset, effectively double breasting the fistula repair and full thickness lower abdominal defect. The patient had an unremarkable postoperative recovery and has since been followed up in the outpatient setting without complication for the past 24 months. Robust coverage of the suprapubic defect was reliably achieved and no further fistulation has occurred. This case illustrates that a pedicled SCIP flap can be harvested as a chimeric flap and used to reliably cover defects in the infra-umbilical region.


Assuntos
Fístula , Retalho Perfurante , Procedimentos de Cirurgia Plástica , Feminino , Humanos , Adulto , Artéria Ilíaca/cirurgia , Bexiga Urinária/cirurgia , Retalho Perfurante/irrigação sanguínea , Fáscia
15.
Artigo em Chinês | MEDLINE | ID: mdl-38296239

RESUMO

Objective: To investigate the clinical effects of free superficial circumflex iliac artery (SCIA) superficial branch perforator flap combined with full-thickness skin graft far from the flap donor site in repairing the large wounds in extremities. Methods: The study was a retrospective observational study. From January 2020 to June 2022, 19 patients with large wounds in extremities who met the inclusion criteria were admitted to the First Affiliated Hospital of Bengbu Medical College, including 15 males and 4 females, aged 28-75 years. The debridement, fracture reduction and fixation, tendon, vessel, and nerve repair, and vacuum sealing drainage were performed in the first stage surgery. After debridement in the second stage surgery, the total wound area was 13.0 cm×8.0 cm-34.0 cm×15.0 cm. The tendon and bone exposed wound with area of 9.0 cm×6.0 cm-14.0 cm×7.0 cm was repaired with free SCIA superficial branch perforator flap with area of 10.0 cm×6.5 cm-15.0 cm×8.0 cm. The remaining granulation tissue wound with area of 5.0 cm×3.5 cm-13.0 cm×8.0 cm was repaired with full-thickness skin graft far from the flap donor site with area of 5.0 cm×3.5 cm-13.0 cm×8.0 cm. All the wounds in donor site were sutured. The operation time and amount of bleeding of patients during the surgery were recorded, the survival of flap and skin graft were observed after surgery. During follow-up, the flap and skin graft, scar in the donor site and its effect on donor site function were observed. At the last follow-up, the satisfaction of patients with the efficacy was evaluated by the efficacy satisfaction rating score. Results: The operation time of patients was 2.0-3.5 h. The amount of bleeding of patients during the surgery was 100-320 mL. One patient had ecchymosis and venous crisis in the edge of flap on the second day after surgery, and the flap survived after exploration. The flaps of the other patients survived smoothly. The skin grafts of patients all survived smoothly. Two patients had bloated flaps due to obesity in the later stage, and the expected results were achieved after flap thinning surgery 6 months after operation. During the follow-up of 6 to 24 months, the flaps had good elasticity and soft texture, and the skin grafts had no wear or ulceration; linear scars were left in all the donor sites but their functions were not affected. The patients were all satisfied with the efficacy. Conclusions: Free SCIA superficial perforator flap combined with full-thickness skin graft far from the donor site was used to repair the large wounds in extremities, which was safe, reliable, and less traumatic and short in operation time, and resulted in good postoperative appearance and function in the donor sites and recipient sites.


Assuntos
Retalho Perfurante , Lesões dos Tecidos Moles , Feminino , Humanos , Masculino , Cicatriz/cirurgia , Artéria Ilíaca/cirurgia , Extremidade Inferior/cirurgia , Retalho Perfurante/irrigação sanguínea , Transplante de Pele , Lesões dos Tecidos Moles/cirurgia , Adulto , Pessoa de Meia-Idade , Idoso
16.
Plast Reconstr Surg ; 153(1): 203-214, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37053456

RESUMO

BACKGROUND: Computer-assisted surgery is widely used in mandibular reconstruction, but the process is not well described for cases using the deep circumflex iliac artery flap (DCIA) as the donor site. This study aimed to present a DCIA-based three-component surgical template system (3-STS) in patients with a mandibular Brown class I defect. METHODS: This retrospective cohort study compared clinical outcomes of mandibular reconstruction with DCIA flap using 3-STS or conventional surgical templates. The primary outcome of the study was the accuracy of reconstruction, and the secondary outcomes included surgical time and bone flap ischemia time. Surgery-related parameters and functional outcomes were also recorded and compared. RESULTS: Forty-four patients (23 in the 3-STS group and 21 in the control group) between 2015 and 2021 were included. Compared with the control group, the 3-STS group had higher accuracy of reconstruction, indicated by lower deviation in absolute distance (1.45 ± 0.76 mm versus 2.02 ± 0.89 mm; P = 0.034), and less deviation in coronal and sagittal angles (0.86 ± 0.53 degree versus 1.27 ± 0.59 degrees, P = 0.039; and 2.52 ± 1.00 degrees versus 3.25 ± 1.25 versus, P = 0.047) between preoperative and postoperative computed tomographic imaging. Surgical time and bone flap ischemia time were significantly reduced in the 3-STS group compared with the control group (median time, 385 minutes versus 445 minutes and 32 minutes versus 53 minutes, respectively; P < 0.001). In addition, masseter attachment was preserved in the 3-STS group but not in the control group. No differences were found in adverse events or other clinical variables. CONCLUSION: The 3-STS can improve accuracy, simplify intraoperative procedures to increase surgical efficiency, and preserve functionality in mandibular reconstruction for Brown class I defects. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, III.


Assuntos
Reconstrução Mandibular , Procedimentos de Cirurgia Plástica , Humanos , Estudos Retrospectivos , Artéria Ilíaca/cirurgia , Mandíbula/cirurgia , Isquemia/cirurgia , Ílio
17.
Urol J ; 21(2): 121-125, 2024 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-37990848

RESUMO

PURPOSE: The choice between using the internal or external iliac arteries to supply a transplanted kidney poses a dilemma during renal transplantation. As the internal iliac artery branches to the genital tract, cutting it could potentially result in sexual dysfunction. The purpose of this study was to compare the effects of these two surgical methods on sexual function. MATERIALS AND METHODS: 122 sexually active male patients under the age of sixty were randomly divided into two groups: the internal iliac anastomosis group and the external iliac artery anastomosis group. Before surgery and one year after the procedure, patients completed the International Index of Erectile Function-15 questionnaire (IIEF- 15), and the difference in scores of each domain was measured. RESULTS: Statistically, kidney transplantation improved all domains of IIEF in both groups, except for erectile function in patients who underwent internal iliac artery anastomosis group. Additionally, there were significant differences between the two groups in the domains of erectile function (p-value=0.04) and overall satisfaction (p-value = 0.002), while other domains such as orgasmic function, sexual desire, and intercourse satisfaction did not show any statistically significant differences. CONCLUSION: In conclusion, the choice between using the internal or external iliac artery for arterial anastomosis during kidney transplantation does not significantly impact graft function. However, it may negatively affect erectile function in patients who undergo internal iliac artery anastomosis.


Assuntos
Disfunção Erétil , Transplante de Rim , Humanos , Masculino , Disfunção Erétil/etiologia , Transplante de Rim/efeitos adversos , Transplante de Rim/métodos , Artéria Ilíaca/cirurgia , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/métodos , Rim
19.
J Plast Reconstr Aesthet Surg ; 88: 33-36, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37950989

RESUMO

Recent advances in minimally invasive perforator flaps, such as the superficial circumflex iliac artery (SCIP) flap, have increased the demand for anastomosing vessels with diameters less than 0.8 mm. However, discrepancies in size can occur, underscoring the significance of end-to-side anastomosis. Nevertheless, the conventional interrupted end-to-side suturing technique with vessel turnover presents challenges in situations with a limited operative field, short vascular pedicle, and tiny vessels. Therefore, we developed an intravascular flipping technique for end-to-side microvascular anastomosis with an inside technique or rotation-outside technique. The study involved 20 rats and with 15 arteries in 10 rats undergoing the flipping technique with inside or outside rotation. Both the inside and rotation-outside techniques exhibited a 100% immediate patency rate in the rats; however, after 1 week, this decreased to 80% and 86%, respectively. The SCIP flap and replantation procedures were successfully performed. The flipping technique offers several advantages, including ease of vessel manipulation using nylon threads and vascular clips, improved vessel visualisation, and spontaneous widening of the vessel lumen.


Assuntos
Microcirurgia , Retalho Perfurante , Ratos , Animais , Microcirurgia/métodos , Artérias/cirurgia , Artéria Ilíaca/cirurgia , Retalho Perfurante/irrigação sanguínea , Anastomose Cirúrgica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA