1.
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue ; 35(10): 1070-1073, 2023 Oct.
Artigo em Chinês | MEDLINE | ID: mdl-37873712

RESUMO

OBJECTIVE: To explore the feasibility of snuff pot arterial pressure measurement for patients undergoing routine elective surgery during anesthesia. METHODS: A prospective randomized controlled trial was conducted. Patients undergoing elective surgery admitted to the Handan Hospital of Traditional Chinese Medicine from June 1, 2020 to June 1, 2022 were enrolled. Patients who needed arterial pressure measurement for hemodynamic monitoring were randomly divided into routine radial artery puncture group and snuff pot artery puncture group with their informed consent. The patients in the routine radial artery puncture group were placed a catheter at the styloid process of the patient's radius to measure pressure. In the snuff pot artery puncture group, the snuff pot artery, that was, the radial fossa on the back of the hand (snuff box), was selected to conduct the snuff pot artery puncture and tube placement for pressure measurement. The indwelling time of arterial puncture catheter, arterial blood pressure, and complications of puncture catheterization of patients in the two groups were observed. Multivariate Logistic regression analysis was used to screen the relevant factors that affect the outcome of arterial catheterization. RESULTS: Finally, a total of 252 patients were enrolled, of which 130 patients received routine radial artery puncture and 122 patients received snuff pot artery puncture. There was no statistically significant difference in general information such as gender, age, body mass index (BMI), and surgical type of patients between the two groups. There was no significant difference in the indwelling time of artery puncture catheter between the routine radial artery puncture group and the snuff pot artery puncture group (minutes: 3.4±0.3 vs. 3.6±0.3, P > 0.05). The systolic blood pressure (SBP) and the diastolic blood pressure (DBP) measured in the snuff pot artery puncture group were significantly higher than those in the conventional radial artery puncture group [SBP (mmHg, 1 mmHg ≈ 0.133 kPa): 162.3±14.3 vs. 156.6±12.5, DBP (mmHg): 85.3±12.6 vs. 82.9±11.3, both P < 0.05]. There was no statistically significant difference in the incidence of complications such as arterial spasm, arterial occlusion, and pseudoaneurysm formation between the two groups. However, the incidence of hematoma formation in the snuff pot artery puncture group was significantly lower than that in the conventional radial artery puncture group (2.5% vs. 4.6%, P < 0.05). Based on the difficulty of arterial puncture, multivariate Logistic regression analysis showed that gender [odds ratio (OR) = 0.643, 95% confidence interval (95%CI) was 0.525-0.967], age (OR = 2.481, 95%CI was 1.442-4.268) and BMI (OR = 0.786, 95%CI was 0.570-0.825) were related factors that affect the outcome of arterial catheterization during anesthesia in patients undergoing elective surgery (all P < 0.05). CONCLUSIONS: Catheterization through the snuff pot artery can be a new and feasible alternative to conventional arterial pressure measurement.


Assuntos
Cateterismo Periférico , Tabaco sem Fumaça , Humanos , Pressão Arterial/fisiologia , Estudos de Viabilidade , Artéria Radial/fisiologia , Estudos Prospectivos , Punções
2.
J Cardiothorac Vasc Anesth ; 37(9): 1631-1638, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37217422

RESUMO

OBJECTIVE: The aortic-to-radial arterial pressure gradient is described during and after cardiopulmonary bypass (CPB), and can lead to underestimating arterial blood pressure. The authors hypothesized that central arterial pressure monitoring would be associated with lower norepinephrine requirements than radial arterial pressure monitoring during cardiac surgery. DESIGN: An observational prospective cohort with propensity score analysis. SETTING: At a tertiary academic hospital's operating room and intensive care unit (ICU). PARTICIPANTS: A total of 286 consecutive adult patients undergoing cardiac surgery with CPB (central group: 109; radial group: 177) were enrolled and analyzed. INTERVENTIONS: To explore the hemodynamic effect of the measurement site, the authors divided the cohort into 2 groups according to a femoral/axillary (central group) or radial (radial group) site of arterial pressure monitoring. MEASUREMENT AND MAIN RESULTS: The primary outcome was the intraoperative amount of norepinephrine administered. Secondary outcomes included norepinephrine-free hours and ICU-free hours at postoperative day 2 (POD2). A logistic model with propensity score analysis was built to predict central arterial pressure monitoring use. The authors compared demographic, hemodynamic, and outcomes data before and after adjustment. Central group patients had a higher European System for Cardiac Operative Risk Evaluation. (EuroSCORE) compared to the radial group-7.9 ± 14.0 versus 3.8 ± 7.0, p < 0.001. After adjustment, both groups had similar patient EuroSCORE and arterial blood pressure levels. Intraoperative norepinephrine dose regimens were 0.10 ± 0.10 µg/kg/min in the central group and 0.11 ± 0.11 µg/kg/min in the radial group (p = 0.519). Norepinephrine-free hours at POD2 were 38 ± 17 hours versus 33 ± 19 hours in central and radial groups, respectively (p = 0.034). The ICU-free hours at POD2 were greater in the central group: 18 ± 13 hours versus 13 ± 13 hours, p = 0.008. Adverse events were less frequent in the central group than in the radial group-67% versus 50%, p = 0.007. CONCLUSIONS: No differences in the norepinephrine dose regimen were found according to the arterial measurement site during cardiac surgery. However, norepinephrine use and length of stay in the ICU were shorter, and adverse events were decreased when central arterial pressure monitoring was used.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cirurgia Torácica , Adulto , Humanos , Pressão Arterial , Artéria Radial/fisiologia , Estudos Prospectivos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ponte Cardiopulmonar , Norepinefrina/uso terapêutico , Pressão Sanguínea/fisiologia
3.
J Cardiothorac Vasc Anesth ; 36(10): 3773-3779, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35768307

RESUMO

OBJECTIVES: This study aimed to evaluate the effect of radial artery cannulation on hand perfusion in patients with normal modified Allen's test undergoing cardiac surgeries using cardiopulmonary bypass (CPB). DESIGN: Prospective follow-up study. SETTING: Single institution, Assiut University Cardiothoracic Hospital. PARTICIPANTS: Forty-nine patients who underwent cardiac surgeries using cardiopulmonary bypass were enrolled. INTERVENTIONS: Cannulation of radial artery in the dominant hand using a 20-gauge catheter. MEASUREMENTS AND MAIN RESULTS: The primary outcomes were the mean peripheral perfusion index (PPI) >60 seconds (mean PPI60) and the thumb temperature, which were measured at different times before and during the surgery. There was a statistically significant difference in the mean PPI60 between both hands (p = 0.033). Before skin incision, the mean PPI60 was significantly higher in the noncannulated hand (p < 0.001). Also, there was a statistically significant difference in the thumb temperature between both hands (p = 0.013). At low core body temperature, the thumb temperature was significantly lower in the noncannulated hand (p = 0.017). CONCLUSIONS: In adult patients undergoing cardiac surgeries using CPB, even with normal modified Allen's test, radial artery cannulation may affect the perfusion of the dominant hand, especially at low arterial blood pressure or low core body temperature. Since the PPI is one of the noninvasive methods used for intraoperative assessment of the peripheral perfusion, the authors recommend the use of the noncannulated hand for this purpose to not misguide this assessment.


Assuntos
Índice de Perfusão , Artéria Radial , Adulto , Cateterismo , Seguimentos , Mãos/irrigação sanguínea , Mãos/cirurgia , Humanos , Perfusão , Estudos Prospectivos , Artéria Radial/fisiologia
4.
J Vasc Surg ; 75(1): 230-237, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34314831

RESUMO

OBJECTIVE: Immature arteriovenous fistula (AVF) is a critical problem in patients with chronic kidney disease (CKD) after creation. Exercise with 30% maximum voluntary contraction (MVC) encourages vascular functions in other populations. It is unknown which exercise type is superior on maturation in the CKD population. We compare effects of isometric (ISM) and isotonic (IST) hand exercise training, both at 30% MVC, on AVF maturation and grip strength in patients with CKD. METHODS: Fifty patients with CKD were randomized into the ISM program or IST program (25 per group). Each group performed exercise program at intensity of 30% MVC every day for 10 weeks. Cephalic vein (CV) and brachial artery diameters, brachial blood flows, and grip strength were measured at weeks 0, 2, 6, and 10 of the program. The number of patients meeting clinical and ultrasound maturation were evaluated at weeks 2, 6, and 10. RESULTS: At weeks 6 and 10 of the programs, the ISM group had greater CV diameters (week 6, 7.1 ± 1.2 vs 6.2 ± 1.0 mm; week 10, 7.1 ± 1.0 vs 6.2 ± 1.1 mm) than the IST group. Compared with the IST group, the ISM group had a higher number of patients meeting ultrasound maturation at weeks 2 (IST/ISM, 8/2), 6 (IST/ISM, 16/8), and 10 (IST/ISM, 21/12), and clinical maturation at week 10 (IST/ISM, 25/18). No adverse events were observed throughout the study. CONCLUSIONS: At 30% MVC, ISM is more effective at promoting increases in CV diameter and maturation than IST. Both exercise types are feasible and safe for patients with CKD after AVF creation.


Assuntos
Derivação Arteriovenosa Cirúrgica/reabilitação , Terapia por Exercício/métodos , Mãos/fisiologia , Diálise Renal/métodos , Insuficiência Renal Crônica/terapia , Idoso , Mãos/irrigação sanguínea , Força da Mão , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Radial/diagnóstico por imagem , Artéria Radial/fisiologia , Artéria Radial/cirurgia , Resultado do Tratamento , Ultrassonografia Doppler , Grau de Desobstrução Vascular/fisiologia , Veias/diagnóstico por imagem , Veias/fisiologia , Veias/cirurgia
5.
PLoS One ; 16(8): e0256130, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34415949

RESUMO

BACKGROUND: There are few reports of renal artery embolization (RAE) via transradial access (TRA) for renal hemorrhage, and none have compared outcomes of RAE via TRA and transfemoral access (TFA). The objective was to compare technical and clinical outcomes in patients undergoing RAE via TRA or TFA for iatrogenic renal hemorrhage. MATERIALS AND METHODS: This study included 45 RAE procedures (16 TRA and 29 TFA) for iatrogenic renal hemorrhage in 43 patients performed at a tertiary referral center between October 2018 and December 2020. Information regarding underlying diseases, coagulation status, angiographic and embolization procedure details, technical and clinical successes, and complications were retrospectively evaluated. RESULTS: There were no differences in demographics, underlying diseases, updated Charlson comorbidity scores, angiographic findings, and volume of contrast material between the TRA and TFA groups. By contrast, prothrombin time and international normalized ratio were significantly lower in the TRA than in the TFA group. Embolic materials differed significantly in the two groups. Procedure duration, fluoroscopy time, digital subtraction angiography number, and dose area product were slightly lower in the TRA than in the TFA group, but the differences were not statistically significant. Technical and clinical success rates in the TRA and TFA groups were 100% and 96.6%, and 100% and 96.6%, respectively. No patient in either group experienced procedure-related complications during a 4 week follow-up period. CONCLUSION: RAE via TRA in the management of iatrogenic renal hemorrhage was safe and feasible, with similar procedure duration and radiation exposure to RAE via TFA. TRA may be an acceptable alternative to TFA in these patients.


Assuntos
Cateterismo Periférico/efeitos adversos , Embolização Terapêutica/métodos , Injúria Renal Aguda , Adulto , Idoso , Angiografia/métodos , Feminino , Artéria Femoral/fisiologia , Hemorragia/etiologia , Humanos , Doença Iatrogênica , Rim/patologia , Masculino , Pessoa de Meia-Idade , Punções , Artéria Radial/fisiologia , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/métodos
6.
BMC Anesthesiol ; 21(1): 152, 2021 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-34006231

RESUMO

BACKGROUND: Measuring blood pressure in patients with obesity is challenging. The ClearSight™ finger cuff (FC) uses the vascular unloading technique to provide continuous non-invasive blood pressure measurements. We aimed to test the agreement of the FC with invasive radial arterial monitoring (INV) in patients with obesity. METHODS: Participants had a body mass index (BMI) ≥45 kg/m2 and underwent laparoscopic bariatric surgery. FC and INV measurements were obtained simultaneously every 5 min on each patient, following induction of anesthesia. Agreement over time was assessed using modified Bland-Altman plots and error grid analysis permitted clinical interpretation of the results. Four-quadrant plots allowed assessment of concordance in blood pressure changes. RESULTS: The 30 participants had a median (IQR) BMI of 50.2 kg/m2 (IQR 48.3-55.3). The observed bias (SD, 95% limits of agreement) for systolic blood pressure (SBP) was 14.3 mmHg (14.1, -13.4 - 42.0), 5.2 mmHg (10.9, -16.0 - 26.5) for mean arterial pressure (MAP) and 2.6 mmHg (10.8, -18.6 - 23.8) for diastolic blood pressure (DBP). Error grid analysis showed that the proportion of readings in risk zones A-E were 90.8, 6.5, 2.7, 0 and 0% for SBP and 91.4, 4.3, 4.3, 0 and 0% for MAP, respectively. Discordance occurred in ≤8% of pairs for consecutive change in SBP, MAP and DBP. CONCLUSIONS: The vascular unloading technique was not adequately in agreement with radial arterial monitoring. Evaluation in a larger sample is required before recommending this technique for intraoperative monitoring of patients with BMI ≥45 kg/m2.


Assuntos
Determinação da Pressão Arterial/instrumentação , Determinação da Pressão Arterial/métodos , Monitorização Intraoperatória/instrumentação , Monitorização Intraoperatória/métodos , Obesidade/cirurgia , Artéria Radial/fisiologia , Adulto , Idoso , Cirurgia Bariátrica , Pressão Sanguínea/fisiologia , Índice de Massa Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/fisiopatologia , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
7.
Am J Kidney Dis ; 78(4): 520-529.e1, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33662481

RESUMO

RATIONALE & OBJECTIVE: Percutaneous arteriovenous fistulas (AVF) are created by establishing a proximal forearm anastomosis and offer a safe and reliable vascular access. This study compares the Ellipsys percutaneous AVF with a proximal forearm Gracz-type surgical AVF, chosen for comparison as it is constructed at the same anatomical site. STUDY DESIGN: Retrospective study of prospectively collected clinical data. SETTING & PARTICIPANTS: All vascular access procedures conducted during a 34-month period were reviewed. The study groups comprised 89 percutaneous AVFs and 69 surgical AVFs. EXPOSURE: Percutaneous or surgical AVF placement. OUTCOME: AVF patency, function, and complications. ANALYTICAL APPROACH: Patency rates for each AVF group were evaluated by competing risk survival analysis using a cumulative incidence function. Association of primary, primary assisted, and secondary patency with the AVF groups was examined by Cox proportional hazard models. RESULTS: Technical success was 100% for both groups. Average procedure times were 14 minutes for percutaneous AVFs and 74 minutes for surgical AVFs (P < 0.001). Proximal radial artery (PRA) was used in all percutaneous AVF cases. Inflow for surgical AVFs included radial (30%), ulnar (12%), and brachial (58%) arteries. Outflow veins for both groups were the cephalic and/or basilic veins. Access flow volumes, times to maturation, and overall numbers of interventions per patient-year were not significantly different. Cumulative incidence of primary patency failure at 12 months was lower for surgical AVF (47% vs 64%, P = 0.1), but secondary patency failure was not different between groups (20% vs 12%, P = 0.3). PRA surgical AVFs had similar primary patency (65% vs 64%, P = 0.8) but higher secondary patency failure rates than percutaneous AVFs at 12 months (34% vs 12%, P = 0.04). LIMITATIONS: Retrospective study with a relatively short follow-up period, and not all patients required hemodialysis at the end of study. CONCLUSIONS: Both percutaneous and surgical AVFs demonstrated high rates of technical success and secondary patency. Percutaneous AVFs required shorter procedure times. The rate of intervention was similar. When a distal radial artery AVF is not feasible, percutaneous AVF might offer an appropriate procedure for creating a safe and functional access, maintaining further proximal forearm surgical AVF creation options.


Assuntos
Derivação Arteriovenosa Cirúrgica/métodos , Antebraço/irrigação sanguínea , Falência Renal Crônica/terapia , Diálise Renal/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Derivação Arteriovenosa Cirúrgica/instrumentação , Artéria Braquial/fisiologia , Feminino , Seguimentos , Humanos , Falência Renal Crônica/diagnóstico , Masculino , Pessoa de Meia-Idade , Artéria Radial/fisiologia , Diálise Renal/instrumentação , Estudos Retrospectivos , Artéria Ulnar/fisiologia , Grau de Desobstrução Vascular/fisiologia
8.
Eur J Appl Physiol ; 120(11): 2525-2532, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32857185

RESUMO

PURPOSE: Animal studies have shown that endothelial denudation abolishes vasodilation in response to increased shear stress. Interestingly, shear-mediated dilation has been reported to be reduced, but not abolished, in coronary artery disease (CAD) patients following catheterization. However, it is not known whether this resulted from a priori endothelial dysfunction in this diseased population. In this study, we evaluated shear-mediated dilation following catheterization in healthy young men. METHODS: Twenty-six (age: 24.4 ± 3.8 years, BMI: 24.3 ± 2.8 kg m-2, VO2peak: 50.5 ± 8.8 ml/kg/min) healthy males underwent unilateral transradial catheterization. Shear-mediated dilation of both radial arteries was measured using flow-mediated dilation (FMD) pre-, and 7 days post-catheterization. RESULTS: FMD was reduced in the catheterized arm [9.3 ± 4.1% to 4.3 ± 4.1% (P < 0.001)] post-catheterization, whereas no change was observed in the control arm [8.4 ± 3.8% to 7.3 ± 3.8% (P = 0.168)]. FMD was completely abolished in the catheterized arm in five participants. Baseline diameter (P = 0.001) and peak diameter during FMD (P = 0.035) were increased in the catheterized arm 7 days post-catheterization (baseline: 2.3 ± 0.3 to 2.6 ± 0.2 mm, P < 0.001, peak: 2.5 ± 0.3 to 2.7 ± 0.3 mm, P = 0.001), with no change in the control arm (baseline: 2.3 ± 0.3 to 2.3 ± 0.3 mm, P = 0.288, peak: 2.5 ± 0.3 to 2.5 ± 0.3 mm, P = 0.608). CONCLUSION: This is the first study in young healthy individuals with intact a priori endothelial function to provide evidence of impaired shear-mediated dilation following catheterization. When combined with earlier studies in CAD patients, our data suggest the catheterization impairs artery function in humans.


Assuntos
Cateterismo/efeitos adversos , Artéria Radial/fisiologia , Dispositivos de Acesso Vascular/efeitos adversos , Vasodilatação , Adulto , Cateterismo/métodos , Endotélio Vascular/fisiologia , Voluntários Saudáveis , Humanos , Masculino
9.
Cardiovasc Eng Technol ; 11(2): 128-133, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31950349

RESUMO

PURPOSE: Carotid artery corrected flow time (cFT) derived from Doppler USG is a known predictor of volume responsiveness. However, it can't be obtained continuously, and is operator dependent. In this prospective study, correlation between Doppler derived carotid artery cFT and pressure transducer derived radial artery cFT was evaluated in adult patients undergoing surgery under general anaesthesia. METHODS: Doppler derived carotid artery cFT were obtained from n = 51 adult patients at n = 125 time points. Simultaneously, pressure transducer waveforms were saved at the time of measurement of carotid artery cFT. Later, images were analyzed by an image processing computer software; both pulse pressure variation and cFT were estimated from pressure transducer waveform. RESULTS: Radial artery flow times measured by two independent observers, were significantly correlated (r2 = 0.99, p < 0.00001). Bland-Altman analysis found limits of agreement - 8.3 to 6.3 ms [mean difference (95% CI) - 0.98 (- 1.63, - 0.32)]. Doppler derived carotid artery cFT & pressure transducer derived radial artery cFT were also significantly correlated [r2 = 0.78, p < 0.0001]. However, radial artery cFT was significantly higher than carotid artery cFT [p < 0.0001, paired sample t test]. Radial artery cFT > 404.4 ms had an sensitivity and specificity of 87.34% and 85% respectively with a grey zone was between 393.7 and 417 ms to predict PPV ≥ 12%. CONCLUSION: Pressure transducer derived radial artery cFT correlated with Doppler derived carotid artery cFT and may be a reasonable predictor of volume responsiveness. Further studies are required to confirm its role in various clinical scenario for prediction of volume responsiveness.


Assuntos
Pressão Arterial , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiologia , Monitorização Hemodinâmica/instrumentação , Artéria Radial/fisiologia , Transdutores de Pressão , Ultrassonografia Doppler , Adulto , Anestesia Geral , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Respiração Artificial , Fatores de Tempo
10.
J Clin Monit Comput ; 34(4): 643-648, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31456071

RESUMO

Cardiac output (CO) is a key hemodynamic variable that can be minimally invasively estimated by pulse wave analysis. Multi-beat analysis is a novel pulse wave analysis method. In this prospective observational clinical method comparison study, we compared CO estimations by multi-beat analysis with CO measured by intermittent pulmonary artery thermodilution (PATD) in adult patients treated in the intensive care unit (ICU) after off-pump coronary artery bypass surgery (OPCAB). We included patients after planned admission to the ICU after elective OPCAB who were monitored with a radial arterial catheter and a pulmonary artery catheter. At seven time points, we determined CO using intermittent PATD (PATD-CO; reference method) and simultaneously recorded the radial arterial blood pressure waveform that we later used to estimate CO using multi-beat analysis (MBA-CO; test method) with the Argos monitor (Retia Medical; Valhalla, NY, USA). Blood pressure waveforms impaired by inappropriate damping properties or artifacts were excluded. We compared PATD-CO and MBA-CO using Bland-Altman analysis accounting for repeated measurements, the percentage error, and the concordance rate derived from four-quadrant plot analysis (15% exclusion zone). We analyzed 167 CO values of 31 patients. Mean PATD-CO was 5.30 ± 1.22 L/min and mean MBA-CO was 5.55 ± 1.82 L/min. The mean of the differences between PATD-CO and MBA-CO was 0.08 ± 1.10 L/min (95% limits of agreement: - 2.13 L/min to + 2.29 L/min). The percentage error was 40.7%. The four-quadrant plot-derived concordance rate was 88%. CO estimation by multi-beat analysis of the radial arterial blood pressure waveform (Argos monitor) shows reasonable agreement compared with CO measured by intermittent PATD in adult patients treated in the ICU after OPCAB.


Assuntos
Pressão Arterial , Débito Cardíaco/fisiologia , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Termodiluição/métodos , Adulto , Idoso , Pressão Sanguínea , Cateterismo de Swan-Ganz , Cuidados Críticos , Feminino , Hemodinâmica , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Estudos Prospectivos , Artéria Pulmonar/fisiopatologia , Artéria Radial/fisiologia
11.
J Surg Res ; 244: 587-598, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31521941

RESUMO

BACKGROUND: Immediate changes in vascular mechanics during aortic cross-clamping remain widely unknown. By using a numerical model of the arterial network, vascular compliance and resistance can be estimated and the time constant of pressure waves can be calculated and compared with results from the classic arterial waveform analysis. METHODS: Experimental data were registered from continuous invasive radial artery pressure measurements from 11 patients undergoing vascular surgery. A stable set of beats were chosen immediately before and after each clamping event. Through the arterial waveform analysis, the time constant was calculated for each individual beat and for a mean beat of each condition as to compare with numerical simulations. Overall proportional changes in resistance and compliance during clamping and unclamping were calculated using the numerical model. RESULTS: Arterial waveform analysis of individual beats indicated a significant 10% median reduction in the time constant after clamping, and a significant 17% median increase in the time constant after unclamping. There was a positive correlation between waveform analysis and numerical values of the time constant, which was moderate (ρ = 0.51; P = 0.01486) during clamping and strong (ρ = 0.77; P ≤ 0.0001) during unclamping. After clamping, there was a significant 16% increase in the mean resistance and a significant 23% decrease in the mean compliance. After unclamping, there was a significant 19% decrease in the mean resistance and a significant 56% increase in the mean compliance. CONCLUSIONS: There are significant hemodynamic changes in vascular compliance and resistance during aortic clamping and unclamping. Numerical computer models can add information on the mechanisms of injury due to aortic clamping.


Assuntos
Pressão Arterial , Modelos Teóricos , Monitorização Intraoperatória/métodos , Artéria Radial/fisiologia , Resistência Vascular , Procedimentos Cirúrgicos Vasculares , Idoso , Idoso de 80 Anos ou mais , Constrição , Estudos Transversais , Feminino , Humanos , Complicações Intraoperatórias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Artéria Radial/lesões , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/prevenção & controle
12.
Acta Anaesthesiol Scand ; 63(5): 594-600, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30648262

RESUMO

BACKGROUND: The distending intravascular pressure at no flow conditions reflects the stressed volume. While this haemodynamic variable is recognised as clinically important, there is a paucity of reports of its range and responsiveness to volume expansion in patients without cardiovascular disease and no reports of correlations to echocardiographic assessments of left ventricular filling. METHODS: Twenty-seven awake (13 male), spontaneously breathing patients without any history of cardiopulmonary, vascular or renal disease were studied prior to induction of anaesthesia. The no-flow equilibrium pressure in the arm following rapid circulatory occlusion (Parm ) was measured via a radial arterial catheter. Transthoracic echocardiography was used to measure left ventricular end diastolic area and volume as well as the diameter of the inferior vena cava. The Parm and echocardiographic variables were measured before and after administration of 500 mL 0.9% NaCl over 10 minutes. Changes were analysed by paired t test, Pearson's correlation and multiple linear regression. RESULTS: Parm increased overall from 22 ± 5 mm Hg to 25 ± 6 mm Hg (mean difference 3.0 ± 4.5 mm Hg, P = 0.002) following the fluid bolus with corresponding increases in arterial pressure and echocardiographic variables. Variability in the direction of the Parm response reflected concomitant changes in vascular compliance. Only weak correlations were observed between changes in Parm and inferior vena cava diameter indexed to body surface area (R2  = 0.29, P = 0.01). CONCLUSION: Preoperative measurements of Parm increased following acute expansion of the intravascular volume. Echocardiography demonstrated poor correlation with Parm .


Assuntos
Ecocardiografia , Hidratação , Artéria Radial/fisiologia , Adulto , Pressão Arterial/fisiologia , Feminino , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Estudos Prospectivos , Veia Cava Inferior/fisiologia
13.
J Cardiothorac Surg ; 14(1): 15, 2019 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-30665449

RESUMO

BACKGROUND: Radial artery (RA) is widely used in coronary artery bypass (CABG) surgery and the prevention of spasm is crucial for graft patency. Botulinum toxin A (BTX-A) and B are commonly used for aesthetic reasons and neuromuscular disorders. They are proven to raise blood flow and increase survival of ischemic skin flaps. In this study we evaluated and compared the vasodilator effects of BTX-A and papaverine on human RA grafts. METHODS: After resting 60 min in isolated organ baths, human RA grafts were examined. Contraction responses for different doses of serotonin (5-HT) and endothelin-1 (ET-1) were evaluated as a percent of maximum contraction response elicited by 80 mM potassium chloride (KCl). The inhibitory effects of BTX-A and papaverine on contraction responses taken at the 0th hour were compared with the 1st and 2nd hour responses. Inhibitory effects of BTX-A and papaverine against the contractile agent were evaluated by comparing the results of the first and last (0th and 2nd hour) application. RESULTS: In low concentrations, when we compared the effects of BTX-A (10- 8 M) and papaverine (10- 6 M) on 5-HT, papaverine was found to be more effective at both the 0th and 2nd hour (p < 0.05). Both BTX-A and papaverine inhibited the maximum contractile effect of ET-1 to the same extent at the 0th hour; but, the inhibitory effect of BTX-A was significantly stronger at the 2nd hour (p < 0.05). In high concentrations, when we compared the effects of BTX-A (10- 6 M) and papaverine (10- 4 M) on 5-HT, papaverine showed stronger inhibition (p < 0.05), whereas both agents had similar action of inhibition on ET-1 mediated maximum contraction responses. CONCLUSION: BTX-A inhibits both ET-1 and 5-HT induced contractions and its effectiveness does not decrease over time as observed with papaverine. This study is the first in the literature using human RA for prevention of vasospasm by BTX-A.


Assuntos
Toxinas Botulínicas Tipo A/farmacologia , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Papaverina/farmacologia , Artéria Radial/transplante , Vasoconstrição/efeitos dos fármacos , Adulto , Idoso , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fármacos Neuromusculares/farmacologia , Artéria Radial/efeitos dos fármacos , Artéria Radial/fisiologia , Vasodilatadores/farmacologia
14.
Br J Ophthalmol ; 103(7): 928-932, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30150277

RESUMO

BACKGROUND/AIMS: Takayasu arteritis (TAK) is a chronic granulomatous vasculitis that can lead to ischaemic ocular complications. We aimed to document ocular complications, ocular blood flow and the association of them with systemic clinical findings in TAK. MATERIAL AND METHODS: We included 65 patients with TAK (60 female, 5 male, mean age: 41.8±12.9 years) and 30 healthy subjects (30 female, mean age: 39.0±7.5 years) in this study. All of the patients had a detailed rheumatological and ophthalmological evaluation. Ocular blood flow in ophthalmic artery (OA) and central retinal artery (CRA) was evaluated with colour Doppler ultrasonography. RESULTS: Hypertensive retinopathy was observed in 33.9%, and Takayasu retinopathy was observed in 6.2% of patients. Posterior subcapsular cataracts or a history of cataract surgery was seen in 15.4% of the cases. None of the patients experienced visual loss due to ischaemic or neovascular complications. Patients with TAK had increased resistivity index (RI) in ophthalmic artery (0.75 vs 0.66, p=0.002) and CRA (0.75 vs 0.67, p=0.001). Patients with hypertensive retinopathy had significantly longer disease duration (p=0.016). Ophthalmic artery RI was significantly higher in patients with ipsilateral radial artery pulselessness compared with patients without (0.77 vs 0.68, p=0.031). CONCLUSION: This study reported the lowest prevalence of Takayasu retinopathy and is the only series without permanent visual loss. We documented for the first time that radial artery pulselessness can predict reduction of ipsilateral ocular perfusion. We believe that better management of TAK with current medications reduced ocular complication rates.


Assuntos
Doenças Retinianas/fisiopatologia , Arterite de Takayasu/complicações , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Estudos Transversais , Feminino , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/fisiopatologia , Artéria Oftálmica/fisiologia , Artéria Radial/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Transtornos da Visão/fisiopatologia
15.
Int J Artif Organs ; 41(10): 635-643, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29998763

RESUMO

OBJECTIVE: To investigate whether radial artery pressure is a reliable surrogate measure of central arterial pressure as approximated by femoral artery pressure in minimally invasive cardiac surgery with retrograde perfusion via femoral cannulation. METHOD: Fifty-two consecutive patients undergoing minimally invasive cardiac surgery were prospectively included in this study. Cardiopulmonary bypass was established via a femoral artery cannulation and femoral vein. Radial and femoral arterial pressures were recorded continuously, and the pressure differential between them was calculated for both systolic and mean arterial pressures. The agreement between measurements from the two arteries was compared using Bland-Altman plots. An interval of 95% limits of agreement of less than 20 mm Hg was set as satisfactory agreement. RESULTS: Average age was 65 ± 14 years. With respect to systolic arterial pressure, 28 patients (54%) had a peak pressure differential between radial and femoral arteries ⩾20 mm Hg. With respect to mean arterial pressure, only five patients (9%) had a peak pressure differential ⩾20 mm Hg. The pressure differential changed with time. Pressure differential in systolic arterial pressure was 5 ± 8 mm Hg until aortic declamping, then increased to a peak of 23 ± 16 mm Hg when cardiopulmonary bypass was turned off. The femoral systolic arterial pressures were significantly greater than radial systolic arterial pressures from time of aortic declamping to 20 min after cardiopulmonary bypass. The Bland-Altman plots revealed large biases and poor agreement in this period. CONCLUSION: Radial and femoral systolic artery pressure readings can differ significantly in minimally invasive cardiac surgery with retrograde perfusion. Intraoperative arterial pressure management based solely on radial systolic arterial pressure readings should be avoided.


Assuntos
Pressão Arterial/fisiologia , Ponte Cardiopulmonar , Artéria Femoral/fisiologia , Artéria Radial/fisiologia , Idoso , Pressão Sanguínea/fisiologia , Feminino , Humanos , Masculino , Monitorização Intraoperatória , Estudos Prospectivos
16.
J Neurointerv Surg ; 10(8): 784-787, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29487193

RESUMO

PURPOSE: The efficiency of neuroendovascular procedures may partly depend on the time devoted to placement of a radial arterial line (RAL) for intraoperative blood pressure monitoring. An alternative approach is to use a pressure-sensing sheath (PSS) that serves to provide invasive blood pressure monitoring without requiring a separate procedure for placement. We compared the use of a RAL versus PSS and assessed procedure time, anesthetist and patient satisfaction, and cost. METHODS: We performed a single-center, prospective, blockwise, comparative trial of procedure start time using traditional RAL placement versus the EndoPhys PSS for invasive blood pressure monitoring. Endpoints included time from room arrival to groin puncture, patient and anesthetist satisfaction ratings, and costs associated with RAL placement. RESULTS: Twenty patients were enrolled in the PSS+RAL arm and 20 in the PSS-alone arm. Mean time from arrival in the room until groin puncture was 61.9±14.0 min in the RAL group and 51.2±10.8 min in the PSS-alone group (P=0.01; difference=10.7 min). Patients in the PSS-alone group reported less pain than those in the RAL group. Furthermore, anesthetists reported accurate blood pressure in the PSS group. The average cost estimate of RAL placement was US$774.70, with a range of US$743 to US$1171. CONCLUSIONS: Placement of a RAL at the start of the neuroendovascular procedures resulted in increased delays to procedure start time and more patient-reported pain compared with the PSS, which may offer a more efficient means of blood pressure monitoring for neurointerventional procedures. CLINICAL TRIAL REGISTRATION: NCT03239847.


Assuntos
Determinação da Pressão Arterial/métodos , Pressão Sanguínea/fisiologia , Monitorização Neurofisiológica Intraoperatória/métodos , Procedimentos Neurocirúrgicos/métodos , Artéria Radial/fisiologia , Dispositivos de Acesso Vascular , Idoso , Pressão Arterial/fisiologia , Feminino , Virilha , Humanos , Monitorização Neurofisiológica Intraoperatória/instrumentação , Masculino , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos/instrumentação , Pressão , Estudos Prospectivos , Dispositivos de Acesso Vascular/normas
18.
J. pediatr. (Rio J.) ; 94(1): 76-81, Jan.-Feb. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-894093

RESUMO

Abstract Objective: Several reports claim that blood pressure (BP) in the radial artery may underestimate the accurate BP in critically ill patients. Here, the authors evaluated differences in mean blood pressure (MBP) between the radial and femoral artery during pediatric cardiac surgery to determine the effectiveness of femoral arterial BP monitoring. Method: The medical records of children under 1 year of age who underwent open-heart surgery between 2007 and 2013 were retrospectively reviewed. Radial and femoral BP were measured simultaneously, and the differences between these values were analyzed at various times: after catheter insertion, after the initiation of cardiopulmonary bypass (CPB-on), after aortic cross clamping (ACC), after the release of ACC, after weaning from CPB, at arrival in the intensive care unit (ICU), and every 6 h during the first day in the ICU. Results: A total of 121 patients who underwent open-heart surgery met the inclusion criteria. During the intraoperative period, from the beginning to the end of CPB, radial MBPs were significantly lower than femoral MBPs at each time-point measured (p < 0.05). Multivariate analysis showed that longer CPB time (>60 min, odds ratio: 7.47) was a risk factor for lower radial pressure. However, discrepancies between these two values disappeared after arrival in the ICU. There was no incidence of ischemic complications associated with the catheterization of both arteries. Conclusion: The authors suggest that femoral arterial pressure monitoring can be safely performed, even in neonates, and provides more accurate BP values during CPB-on periods, and immediately after weaning from CPB, especially when CPB time was greater than 60 min.


Resumo Objetivo: Diversos relatos alegam que a pressão arterial (PA) na artéria radial poderá subestimar a PA precisa em pacientes gravemente doentes. Aqui, avaliamos diferenças na pressão arterial média (PAM) entre a artéria radial e femoral durante cirurgia cardíaca pediátrica para determinar a eficácia do monitoramento da PA da artéria femoral. Método: Realizamos uma análise retrospectiva de prontuários médicos de crianças com menos de 1 ano de idade submetidas a cirurgia de coração aberto entre 2007 e 2013. As PAs radial e femoral foram auferidas simultaneamente, as diferenças entre esses valores foram analisadas diversas vezes: após a inserção do cateter, após o início do bypass cardiopulmonar (CPB-on), após pinçamento cruzado da aorta (ACC), após a liberação do ACC, após desmame do CPB, na entrada na unidade de terapia intensiva (UTI) e a cada 6 horas durante o primeiro dia na unidade de terapia intensiva (UTI). Resultados: Um total de 121 pacientes submetidos a cirurgia de coração aberto atenderam aos nossos critérios de inclusão. Durante o transoperatório, do início ao término do CPB, as PAMs da artéria radial foram significativamente menores do que as PAMs da artéria femoral em cada ponto de medição (p < 0,05). A análise multivariada mostrou que a duração mais longa do CPB (> 60 minutos, Razão de Chance = 7,47) representou um fator de risco de pressão radial mais baixa. Contudo, as diferenças entre esses dois valores desapareceram após a entrada na UTI. Não houve incidência de complicações isquêmicas associadas à cateterização de ambas as artérias. Conclusão: Sugerimos que o monitoramento da pressão arterial femoral pode ser realizado com segurança, mesmo em neonatos, e fornece valores da PA mais precisos durante períodos de CPBon e imediatamente após o desmame do CPB, principalmente nos casos em que a duração do CPB foi superior a 60 minutos.


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Lactente , Ponte Cardiopulmonar , Monitorização Intraoperatória/métodos , Artéria Radial/fisiologia , Artéria Femoral/fisiologia , Pressão Arterial/fisiologia , Procedimentos Cirúrgicos Cardíacos/métodos , Estudos Retrospectivos
19.
J Clin Monit Comput ; 32(1): 13-22, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28105538

RESUMO

Intermittent non-invasive blood pressure measurement with tourniquets is slow, can cause nerve and skin damage, and interferes with other measurements. Invasive measurement cannot be safely used in all conditions. Modified arterial tonometry may be an alternative for fast and continuous measurement. Our aim was to compare arterial tonometry sensor (BPro®) with invasive blood pressure measurement to clarify whether it could be utilized in the postoperative setting. 28 patients who underwent elective surgery requiring arterial cannulation were analyzed. Patients were monitored post-operatively for 2 h with standard invasive monitoring and with a study device comprising an arterial tonometry sensor (BPro®) added with a three-dimensional accelerometer to investigate the potential impact of movement. Recordings were collected electronically. The results revealed inaccurate readings in method comparison between the devices based on recommendations by Association for the Advancement of Medical Instrumentation (AAMI). On a Bland-Altman plot, the bias and precision between these two methods was 19.8 ± 16.7 (Limits of agreement - 20.1 to 59.6) mmHg, Spearman correlation coefficient r = 0.61. For diastolic pressure, the difference was 4.8 ± 7.7 (LoA - 14.1 to 23.6) mmHg (r = 0.72), and for mean arterial pressure it was 11.18 ± 11.1 (LoA - 12.1 to 34.2) mmHg (r = 0.642). Our study revealed inaccurate agreement (AAMI) between the two methods when measuring systolic and mean blood pressures during post-operative care. The readings for diastolic pressures were inside the limits recommended by AAMI. Movement increased the failure rate significantly (p < 0.001). Thus, arterial tonometry is not an appropriate replacement for invasive blood pressure measurement in these patients.


Assuntos
Pressão Arterial , Determinação da Pressão Arterial/métodos , Monitores de Pressão Arterial , Cuidados Críticos/métodos , Manometria/métodos , Monitorização Fisiológica/métodos , Artéria Radial/fisiologia , Aceleração , Adulto , Idoso , Idoso de 80 Anos ou mais , Pressão Sanguínea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador
20.
J Pediatr (Rio J) ; 94(1): 76-81, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28866320

RESUMO

OBJECTIVE: Several reports claim that blood pressure (BP) in the radial artery may underestimate the accurate BP in critically ill patients. Here, the authors evaluated differences in mean blood pressure (MBP) between the radial and femoral artery during pediatric cardiac surgery to determine the effectiveness of femoral arterial BP monitoring. METHOD: The medical records of children under 1 year of age who underwent open-heart surgery between 2007 and 2013 were retrospectively reviewed. Radial and femoral BP were measured simultaneously, and the differences between these values were analyzed at various times: after catheter insertion, after the initiation of cardiopulmonary bypass (CPB-on), after aortic cross clamping (ACC), after the release of ACC, after weaning from CPB, at arrival in the intensive care unit (ICU), and every 6h during the first day in the ICU. RESULTS: A total of 121 patients who underwent open-heart surgery met the inclusion criteria. During the intraoperative period, from the beginning to the end of CPB, radial MBPs were significantly lower than femoral MBPs at each time-point measured (p<0.05). Multivariate analysis showed that longer CPB time (>60min, odds ratio: 7.47) was a risk factor for lower radial pressure. However, discrepancies between these two values disappeared after arrival in the ICU. There was no incidence of ischemic complications associated with the catheterization of both arteries. CONCLUSION: The authors suggest that femoral arterial pressure monitoring can be safely performed, even in neonates, and provides more accurate BP values during CPB-on periods, and immediately after weaning from CPB, especially when CPB time was greater than 60min.


Assuntos
Pressão Arterial/fisiologia , Procedimentos Cirúrgicos Cardíacos/métodos , Ponte Cardiopulmonar , Artéria Femoral/fisiologia , Monitorização Intraoperatória/métodos , Artéria Radial/fisiologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos