Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 117(11): 5733-5740, 2020 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-32123103

RESUMO

The field of chemical modification of proteins has been dominated by random modification of lysines or more site-specific labeling of cysteines, each with attendant challenges. Recently, we have developed oxaziridine chemistry for highly selective modification of methionine called redox-activated chemical tagging (ReACT) but have not broadly tested the molecular parameters for efficient and stable protein modification. Here we systematically scanned methionines throughout one of the most popular antibody scaffolds, trastuzumab, used for antibody engineering and drug conjugation. We tested the expression, reactivities, and stabilities of 123 single engineered methionines distributed over the surface of the antibody when reacted with oxaziridine. We found uniformly high expression for these mutants and excellent reaction efficiencies with a panel of oxaziridines. Remarkably, the stability to hydrolysis of the sulfimide varied more than 10-fold depending on temperature and the site of the engineered methionine. Interestingly, the most stable and reactive sites were those that were partially buried, presumably because of their reduced access to water. There was also a 10-fold variation in stability depending on the nature of the oxaziridine, which was determined to be inversely correlated with the electrophilic nature of the sulfimide. Importantly, the stabilities of the best analogs were sufficient to support their use as antibody drug conjugates and potent in a breast cancer mouse xenograft model over a month. These studies provide key parameters for broad application of ReACT for efficient, stable, and site-specific antibody and protein bioconjugation to native or engineered methionines.


Assuntos
Aziridinas/análise , Imunoconjugados/química , Metionina/análise , Animais , Antineoplásicos/normas , Linhagem Celular Tumoral , Estabilidade de Medicamentos , Feminino , Humanos , Imunoconjugados/genética , Imunoconjugados/imunologia , Camundongos , Camundongos Nus , Engenharia de Proteínas/métodos , Estabilidade Proteica
2.
J Pharm Biomed Anal ; 55(3): 458-65, 2011 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-21420819

RESUMO

A simple, fast and fully automated method for the screening of aziridine (AZD) and 2-chloroethylamine (CEA) in active pharmaceutical ingredients (API) has been developed. The method is based on the in-fiber derivatization of the amines extracted from the sample headspace (previously dissolved or suspended in alkaline water) with 2,3,4,5,6-pentafluorobenzoyl chloride (PFBCl) previously adsorbed in the PDMS/DVB solid phase microextraction (SPME) fiber. The derivatives formed are further desorbed and analyzed in a gas chromatograph with negative ion chemical ionization mass spectrometry (GC-NCI-MS) using methane as reagent gas. The different operational parameters of the procedure have been optimized to get highest sensitivity. The validation of the method, however, revealed a poor repeatability, particularly evident in water-soluble APIs (RSD>20% for AZD). In spite of that, the low detection limits (1-3ngg(-1) for AZD and CEA), speed (44min total analysis time) and automation make that this method can be satisfactorily used as screening tool to accept or reject API batches attending to their volatile amine content and a critical specified value derived from the 1.5µg/day Threshold of Toxicological Concern (TTC) and maxima daily dosages. This was shown by analyzing seventy-five fluvoxamine maleate samples containing known levels of AZD and CEA (between 0.05 and 1.05µgg(-1)) in intermediate reproducibility conditions to get reliable estimations of precision and linearity. From these data, acceptance, rejection and non-conclusive areas of response are defined for both analytes at different confidence and replication levels using normal statistics. The method was satisfactorily applied to real fluvoxamine maleate samples.


Assuntos
Aziridinas/análise , Etilaminas/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Preparações Farmacêuticas/análise , Adsorção , Automação , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Indicadores e Reagentes , Limite de Detecção , Preparações Farmacêuticas/normas , Reprodutibilidade dos Testes , Microextração em Fase Sólida
3.
Pharmazie ; 63(11): 796-805, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19069239

RESUMO

Two new bladder instillations of the investigational anticancer agent EO-9 containing 2-hydroxypropyl-beta-cyclodextrin (HP beta CD) and the alkalizers sodium bicarbonate (NaHCO3) and tri(hydroxymethyl)aminomethane (Tris) were developed. During the stability study of these freeze-dried products, formation of new degradation products was seen. We have characterized these products by high performance liquid chromatography in combination with photodiode array detection and mass spectrometry. In total, five new degradation products were identified of which three were detected in both freeze-dried products and two only in the freeze-dried product composed of EO-9/HP beta CD/NaHCO3. Furthermore, the purity profile of two lots of EO-9 drug substance was investigated. Five, probably synthetic intermediates were found. However, the amount of total impurities was very small for both lots of drug substance and below acceptable international limits for pharmaceutical use.


Assuntos
Antineoplásicos/análise , Aziridinas/análise , Indolquinonas/análise , 2-Hidroxipropil-beta-Ciclodextrina , Cromatografia Líquida de Alta Pressão , Estabilidade de Medicamentos , Excipientes , Liofilização , Concentração de Íons de Hidrogênio , Espectrometria de Massas , Espectrofotometria Ultravioleta , beta-Ciclodextrinas
5.
J Chromatogr ; 615(2): 309-15, 1993 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-8335709

RESUMO

A reversed-phase isocratic high-performance liquid chromatographic method is described for the simultaneous determination of EO9, 3-hydroxymethyl-5-aziridinyl-1-methyl-2-(1H-indole-4,7-dione)prop-beta- en-alpha-ol (I), and its ring-opened aziridine analogue EO5A (II), employing ultraviolet detection. Solid-phase sample extraction was used without addition of an internal standard. Plots of peak heights and areas of I and II were linear in the range 5-10,000 ng/ml. The lower limit of detection of both I and II in plasma was 2 ng/ml. The between-day variation of I was 13.9% at 5 ng/ml and lower than 6.2% for concentrations > or = 10 ng/ml. The between-day variation of II at 5 ng/ml was 13.8% and lower than 4.5% for concentrations > or = 10 ng/ml. The assay was developed to enable pharmacological guiding of a phase I study of I in solid tumour cancer patients.


Assuntos
Antineoplásicos/análise , Aziridinas/análise , Indolquinonas , Indóis/análise , Antineoplásicos/sangue , Antineoplásicos/urina , Aziridinas/sangue , Aziridinas/urina , Cromatografia Líquida de Alta Pressão , Humanos , Indicadores e Reagentes , Indóis/sangue , Indóis/urina , Espectrofotometria Ultravioleta
6.
J Chromatogr ; 532(2): 321-36, 1990 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-2084129

RESUMO

A high-performance liquid chromatographic method for the determination of the novel indoloquinone antitumour agent E09, 3-hydroxymethyl-5-aziridinyl-1-methyl-2-(1H-indole-4,7-dione)prop-beta-e n-alpha - ol, in mouse plasma and urine is described. Following protein precipitation by means of methanol (2 volumes), separation and quantification of parent drug, metabolites and internal standard E012 (5-morpholine substituted analogue) were achieved on a 5-microns Resolve C18 Rad-Pak with a 15-min linear gradient of 10-30% acetonitrile in a 0.02 M pH 7.4 sodium phosphate buffer with UV detection at 280 and 310 nm. The utility of the assay is also demonstrated for the aziridine ring-opened analogue E05A. 3-hydroxymethyl-5-beta-hydroxyethylamino-2-(1H-indole-4,7-dione)pr op-beta-en- alpha-ol. Plots of area ratios of analytes versus internal standard were linear in the range 50-15,000 ng/ml. The detection limit for indoloquinones in plasma was ca. 30 ng/ml. The within-assay and day-to-day variation were consistently lower than 12.5%. The assay was applied in preliminary pharmacokinetic investigations. One minor metabolite of E09 could be identified; further metabolites were characterized by ultraviolet-visible spectra.


Assuntos
Antineoplásicos/análise , Aziridinas/análise , Cromatografia Líquida de Alta Pressão/métodos , Indolquinonas , Indóis/análise , Quinonas/análise , Animais , Antineoplásicos/farmacocinética , Aziridinas/sangue , Aziridinas/urina , Cromatografia Líquida de Alta Pressão/estatística & dados numéricos , Meia-Vida , Indóis/sangue , Indóis/urina , Espectroscopia de Ressonância Magnética , Masculino , Camundongos , Camundongos Endogâmicos C3H , Quinonas/sangue , Quinonas/urina , Espectrofotometria Ultravioleta
7.
Biomed Environ Mass Spectrom ; 19(6): 348-52, 1990 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-2113408

RESUMO

A packed-column supercritical-fluid chromatograph was interfaced with a mass spectrometer via a modification of a thermospray probe. This modification allowed a capillary restrictor for the supercritical fluid (CO2) and reagent gas for chemical ionization to be introduced directly into a thermospray source. Chemical ionization conditions were observed when either the filament or discharge electrode was used and the source pressure was above 0.5 torr. The discharge electrode produced more efficient ionization, resulting in approximately a tenfold larger signal than that observed in the filament mode. The usefulness of this instrumentation was demonstrated on several anticancer drugs. Methanol positive ion chemical ionization (PICI) spectra were recorded for cyclophosphamide, diaziquone, mitomycin C and thiotepa. Methane PICI spectra of thiotepa were obtained in the absence of methanol as a mobile-phase modifier. A 50 ng on-column injection of diaziquone produced approximately a 6:1 signal to noise ratio in the scanning mode.


Assuntos
Antineoplásicos/análise , Benzoquinonas , Aziridinas/análise , Cromatografia/instrumentação , Cromatografia/métodos , Ciclofosfamida/análise , Espectrometria de Massas/instrumentação , Espectrometria de Massas/métodos , Mitomicina , Mitomicinas/análise , Tiotepa/análise
8.
Free Radic Res Commun ; 8(4-6): 231-9, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-2162311

RESUMO

The mechanisms of cytotoxicity of the antitumour diaziridinylbenzoquinones, AZQ and BZQ, have been investigated. HPLC analysis has been used to study the products as well as the rate of decomposition of acid-assisted ring-opening in aqueous medium as a function of pH. Microconcentrators with a molecular weight cutoff of 30 kDa were utilised to study the covalent binding of both compounds to calf thymus DNA. Radical production of both compounds in K562 cell incubations was followed using ESR and their uptake into K562 cells was monitored using radiolabelled compounds. The results show that these two diaziridinylbenzoquinones, although very similar in structure, have diverse mechanisms of cytotoxicity. The implications of these findings are discussed in the light of antitumor action.


Assuntos
Antineoplásicos/farmacologia , Aziridinas/farmacologia , Benzoquinonas , Sobrevivência Celular/efeitos dos fármacos , Alquilantes , Animais , Aziridinas/análise , Cromatografia Líquida de Alta Pressão , DNA/efeitos dos fármacos , Estabilidade de Medicamentos , Espectroscopia de Ressonância de Spin Eletrônica , Radicais Livres , Humanos , Concentração de Íons de Hidrogênio , Cinética , Oxirredução
9.
J Pharm Sci ; 74(12): 1249-54, 1985 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-4087189

RESUMO

In order to understand the redox properties of diaziquone (AZQ) and the reductive alkylation role of its one-electron reduced free radical anion AZQ- in biological systems, we investigated the electrochemical and structural properties of AZQ and its reduced species by cyclic voltammetry, controlled potential electrolysis, optical absorbance spectroscopy and 1H NMR. This study was carried out in aqueous media as well as in Me2SO. In aqueous media AZQ can be reduced by 2 electrons to the dianion AZQ2- which is oxidized back to AZQ- and AZQ. In Me2SO, 1 - e- reduction or oxidation steps are possible. This allowed the characterization of AZQ and its 1 or 2 - e- reduced species by UV-visible absorbance spectroscopy. The redox properties of the aziridine rings were observed by cycle voltammetry. Using 1H NMR, it was possible to follow the structural dependence of AZQ on the nature of the medium. Protonation of the aziridine rings at low pH may facilitate the opening of the ring leading to the carbonium ion, the required species for alkylation. Cyclic voltammetry data indicate that reduction of the quinone facilitates the aziridine ring opening.


Assuntos
Antineoplásicos/análise , Aziridinas/análise , Azirinas/análise , Benzoquinonas , Biotransformação , Dimetil Sulfóxido , Eletroquímica , Concentração de Íons de Hidrogênio , Espectroscopia de Ressonância Magnética , Oxirredução , Solventes , Espectrofotometria Ultravioleta
10.
J Pharm Sci ; 70(2): 159-62, 1981 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-7205219

RESUMO

The application of a rapid, selective, and sensitive reversed-phase high-performance liquid chromatographic method to the analysis of 2,5-diaziridinyl-3,6-bis(carboethoxyamino)-1,4-benzoquinone (I) and its degradation products is described. The method was used to study the kinetics of degradation of I over pharmaceutically useful pH ranges. The overall reaction rate followed pseudo-first-order kinetics. The pH-rate profile demonstrated optimal stability between pH 6.0 and 6.5. The degradation behavior suggests the existence of multiple pathways. The temperature dependence of th disappearance of I also was evaluated from the regression equation derived from the Arrhenius plot.


Assuntos
Antineoplásicos , Aziridinas , Azirinas , Benzoquinonas , Antineoplásicos/análise , Aziridinas/análise , Azirinas/análise , Cromatografia Líquida de Alta Pressão/métodos , Composição de Medicamentos , Estabilidade de Medicamentos , Concentração de Íons de Hidrogênio , Cinética , Solubilidade , Soluções , Temperatura
11.
J Pharm Sci ; 70(2): 162-7, 1981 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-7205220

RESUMO

A direct high-performance liquid chromatographic (HPLC) method was applied to monitor 2,5-diaziridinyl-3,6-bis(carboethoxyamino)-1,4-benzoquinone (I) and its degradation products in pharmaceutical vehicles at 25 +/- 0.1 degrees. At the optimal pH for stability of I, an increase in buffer concentration [phosphate and tris(hydroxymethyl)-aminomethane] or ionic strength accelerated degradation. The reaction rate in the solutions studied followed pseudo-first-order kinetics. Degradation products were characterized by mass spectrometry after isolation by semipreparative HPLC. Different degradation pathways prevailed in acidic and basic media. The acid-catalyzed reaction resulted in consecutive aziridine ring opening, while the base-catalyzed reaction led to nucleophilic displacement of thie aziridine ring(s).


Assuntos
Antineoplásicos/análise , Aziridinas/análise , Azirinas/análise , Benzoquinonas , Soluções Tampão , Fenômenos Químicos , Química , Cromatografia Líquida de Alta Pressão/métodos , Hidrólise , Luz , Espectrometria de Massas/métodos , Oxigênio
12.
Biomed Mass Spectrom ; 7(9): 405-9, 1980 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-6451244

RESUMO

Mass spectrometry has been used for testing the chemical purity of some new antitumor cyclophosphazene compounds. the spectrum of N3P3Az6 (code name MYKO 63)--which exhibits noticeable activity on murine P 388, L 1210 and B 16 tumors--appeared to be remarkably simple, as most of the fragmentations arose from successive losses of the aziridino radicals. Traces of the pentaziridinomonochloro impurity formed by an incomplete substitution of N3P3Cl6 chlorine atoms under aziridinolysis could be detected in an impure and toxic sample by spectral subtraction. Quantification of this impurity was performed by selected ion monitoring in the direct inlet mode of sample introduction. The mass spectra of other derivatives of this class of compounds are slightly more complex, since the decomposition pathways showed more intense H-transfers associated with the loss of substituents.


Assuntos
Antineoplásicos/análise , Aziridinas/análise , Azirinas/análise , Contaminação de Medicamentos , Aziridinas/análogos & derivados , Fenômenos Químicos , Química , Espectrometria de Massas
13.
Arch Environ Health ; 33(1): 33-5, 1978.
Artigo em Inglês | MEDLINE | ID: mdl-147061

RESUMO

A personal monitoring badge has been developed for the detection of the direct-acting, alkylating carcinogen beta-propiolactone at atmospheric concentrations as low as 6 ppb for 24-hour and 0.6 ppm for 0.25-hour exposure. The method employs the trapping reagent p-nitrobenzyl pyridine (p-NBP) absorbed on a cellulose thin-layer chromatography (TLC) strip. Deoxyguanosine can be used in place of p-NBP, but its lower limit of detection is 60 ppb for 24-hour exposure. The authors also obtained positive results with the carcinogens bis (chloromethyl) ether, chloromethyl methyl ether, diepoxybutane, dimethylcarbamoyl chloride, ethyleneimine, and glycidaldehyde. In practice, the TLC strip is positioned in a filmbadge holder. The TLC strip monitoring badges are easy to prepare; they should encounter no resistance of personnel to their use since they are not cumbersome. Monitoring at the end of an exposure is simple and requires no expensive equipment or specialized personnel.


Assuntos
Poluentes Atmosféricos/análise , Cromatografia em Camada Fina/métodos , Indicadores e Reagentes , Lactonas/análise , Propiolactona/análise , Fitas Reagentes , Aziridinas/análise , Éter Bisclorometílico/análise , Compostos de Epóxi/análise , Éteres Metílicos/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA