1.
Int J Prosthodont ; 37(1): 41-48, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-37222545

RESUMO

PURPOSE: To evaluate the effect of adding tea tree oil to denture liners on Candida albicans and bond strength to the acrylic denture base. MATERIALS AND METHODS: Disc-shaped specimens were fabricated from silicone-based resilient liner (Tokuyama, Molloplast), acrylic-based hard liner (GC Reline), and acrylic-based soft liner (Visco-gel). Tea tree oil (TTO) was incorporated into the liners at varying concentrations (0% [control], 2%, 5%, 8%). C albicans were counted by viable colony count, and optical density (OD) was measured with a spectrophotometer. The tensile strength to heat polymerized acrylic denture base was measured in a universal testing machine. The compliance of the data to the distribution of normality was evaluated using the Shapiro Wilk test. Two-way ANOVA, Bonferroni correction, and paired sample t test were performed (α = .05). RESULTS: The addition of TTO into liners provided a significant decrease in the OD values (P < .001). The control groups of the liners presented the highest colony counts, whereas increasing TTO decreased the results (P < .01). According to tensile bond strength test, 8% TTO addition resulted in a significant decrease for Tokuyama (P < .01) and Molloplast liners (P < .05), while 2% TTO resulted in significance for GC Reline (P < .001). CONCLUSIONS: Denture liners containing increasing percentages of TTO presented lower amounts of C albicans colonies and decreased bond strength to the denture bases. When using TTO for its antifungal properties, the amount added should be carefully selected because the tensile bond strength may be affected.


Assuntos
Colagem Dentária , Reembasadores de Dentadura , Óleo de Melaleuca , Elastômeros de Silicone/química , Bases de Dentadura , Candida albicans , Óleo de Melaleuca/farmacologia , Resinas Acrílicas/química , Teste de Materiais , Polimetil Metacrilato , Resistência à Tração
2.
J Mech Behav Biomed Mater ; 150: 106308, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38113822

RESUMO

OBJECTIVES: The present investigation is aimed at evaluating the effect of styrene butadiene rubber, glass fibre, nylon fibre and hybrid reinforcement of glass and nylon fibre with 0.5 and 1.0 wt% on the impact, flexural, and compressive properties. METHODS: A total of 19 groups were formed, including one control group and 18 study groups. All specimens were fabricated according to the standards and tests were performed. The enhancement of strengths were characterised by using scanning electron micrographs, FTIR results, XRD, and DMA tests. The degradability was studied using TGA/DTA analysis. The results were analysed using one-way ANOVA and Dunnett's post hoc multiple comparison test at p ≤ 0.05. RESULTS: The maximum impact, flexural, and compressive strength were found to be 3.234 ± 0.202 kJ/m2, 70.07 ± 0.7 MPa, and 84.929 ± 0.85 MPa for hybrid reinforcement of 0.5 wt% nylon fiber and 0.5 wt% glass fiber with 1.0 wt% of styrene butadiene rubber (SBR) mixed PMMA denture base material. Statistical analysis shows that the maximum mean impact strength, flexural strength, and compressive strength are about 84%, 58%, and 67% higher than the pure PMMA (control group). The maximum flexural modulus and compressive modulus are 914.4 MPa and 407.847 MPa for denture base material made of 1.0 wt% SBR, 1.0 wt% nylon fiber, 0.5 wt% glass fiber, and 0.5 wt% SBR, 0.5 wt% nylon fiber, respectively. The storage moduli of 1.0 wt% SBR, 1.0 wt% nylon fiber, and 0.5 wt% glass fiber-reinforced denture base material and pure PMMA are 0.096 and 0.422 at 79 °C, respectively, which indicates significant crosslinking of fiber and PMMA. The failure surfaces are characterized by a homogeneous distribution of fiber with increased surface roughness and fiber pullout, strong bonding, and well-dispersed SBR.


Assuntos
Nylons , Polimetil Metacrilato , Borracha , Bases de Dentadura , Butadienos , Teste de Materiais , Maleabilidade , Vidro
3.
Photobiomodul Photomed Laser Surg ; 41(11): 608-621, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37910776

RESUMO

Objective: This systematic review and meta-analysis aimed to assess the influence of laser treatment on adhesive bonding of liners to polymethyl methacrylate (PMMA) denture base resins. Methods: The focused question was: "Does the application of laser treatment (Intervention) influence the adhesive bonding strength (Outcome) of liners to PMMA denture base resins (Population) as compared with untreated or unconditioned surfaces (Control)?" In vitro and clinical reports as well as reports on influence of laser treatments on bonding strength of liners to PMMA denture resins in comparison with untreated surfaces were included. Reports without any control group[s], without any application of laser[s] for PMMA denture bases that did not utilize PMMA denture bases, and not evaluate bond strength of PMMA denture base resins were excluded. An electronic search was conducted on PubMed, Scopus, and Web of Science. Meta-analyses were performed for calculating the standard mean difference (SMD) with a 95% confidence interval (95% CI). Results: Nine of the 12 included studies found that laser irradiation treatment produced significant surface texture alterations of the PMMA denture base and improved the adhesion between the PMMA denture base and soft lining. According to the meta-analysis, tensile bond strength showed an SMD of -2.49% (95% CI: -3.89 to -1.08; p = 0.0005), suggesting a statistically significant difference between the control and test groups (i.e., favoring laser-treated samples than untreated samples). Regarding shear bond strength scores, the outcomes showed an SMD of -2.24% (95% CI: -3.79 to -0.69; p = 0.005), suggesting a statistically significant difference between the control and test groups (i.e., favoring laser-treated samples than untreated samples). Conclusions: Despite the high heterogeneity among the included studies, it can be concluded that laser treatment might improve the bonding strengths of liners to PMMA denture base resins as compared with untreated surfaces. To validate the aforementioned conclusions, further verification is required through the implementation of well-designed randomized controlled trials with large sample sizes.


Assuntos
Reembasadores de Dentadura , Polimetil Metacrilato , Polimetil Metacrilato/química , Adesivos , Resinas Acrílicas/química , Teste de Materiais , Bases de Dentadura
4.
Dent Mater J ; 42(2): 167-176, 2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-36476683

RESUMO

This study aimed to evaluate the hardness, roughness, and color stability of heat- and microwave-polymerized polymethyl methacrylate (PMMA), polyamide, and CAD-CAM PMMA resins when exposed to cigarette smoke (CS) and immersed in a denture cleanser (DC). Specimens of each resins were divided into four subgroups (n=10). The DC and CS+DC specimens were immersed in a DC; the CS and CS+DC specimens were exposed to CS; and the control (C) specimens were kept in distilled water. Hardness, roughness, and color measurements were performed. DC and CS significantly affected the roughness and color of all resins (p<0.05). However, these did not affect the hardness of the CAD-CAM PMMA resin (p>0.05). The CAD-CAM PMMA resin presented the lowest roughness, highest hardness, and lowest ΔE00 values. While the roughness of all resins exposed to CS when immersed in DC decreased, the ΔE00 values of the conventional PMMAs also decreased. Although this decreases were not significant, it may be advisable to use DC for smokers to decrease discoloration and roughness especially for conventional PMMAs resins.


Assuntos
Fumar Cigarros , Higienizadores de Dentadura , Bases de Dentadura , Polimetil Metacrilato , Teste de Materiais , Propriedades de Superfície , Desenho Assistido por Computador
5.
Eur J Prosthodont Restor Dent ; 31(1): 1-9, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-35993535

RESUMO

This review aimed to identify the influence of antimicrobial and cleaning agents on surface characteristics such as surface free energy (SFE) and wettability, and microbial adhesion in polymethylmethacrylate (PMMA) for denture base. The review question, based on PICO, was: "Does intervention with antimicrobial and cleaning agents in PMMA influence the surface free energy, wettability, and consequently the microbial adhesion?" and the protocol was registered in Open Science Framework (osf. io/v3xgn). The search was performed in PubMed, Lilacs, Embase, Scopus, and Science Direct databases, using the terms: ("acrylic resin" OR PMMA) AND (antimicrobial OR antibacterial) AND ("electrostatic interaction" OR surface free energy) AND (biofilm OR "bacteria adhesion"), and resulted in 462 articles, of which 7 were included. The antimicrobials polypara-xylylene, carboxybetaine methacrylate, ethylene glycol methacrylate phosphate, and deposition of F and Ag ions in PMMA influenced the SFE and wettability. Denture cleaners reduced microbial adhesion. Five of the included studies evaluated the microbial adhesion, however, only two observed a direct relationship between SFE, wettability, and microbial adhesion. It was concluded that the intervention with antimicrobial and cleaning agents in PMMA can interfere in SFE and surface wettability, but no correlation was observed between microbial adhesion and these surface characteristics in PMMA.


Assuntos
Anti-Infecciosos , Polimetil Metacrilato , Propriedades de Superfície , Bases de Dentadura/microbiologia , Candida albicans , Teste de Materiais
6.
J Cancer Res Ther ; 19(7): 2031-2035, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38376313

RESUMO

CONTEXT: Different denture cleansers have an effect on color and different surface properties of polyamide denture base material. Thus, selecting a denture cleanser solution for polyamide denture base materials should be based on the properties of the denture cleanser itself. The present in vitro study is aimed to evaluate and compare the effect of different denture base cleansers on color, surface roughness and hardness of polyamide denture base material. METHODS AND MATERIAL: Thirty specimens of commercially available polyamide denture base material were fabricated and divided into three groups of 10 each. Specimens from each group were immersed in different denture cleansers (sodium perborate, thyme oil and ozonated water) for 10 mins per day for 180 days. Initial and final color, surface roughness and surface hardness of each specimen were measured and the difference was calculated. Data was tabulated and subjected to statistical analysis using One way ANOVA for pair wise comparison. RESULTS: Polyamide denture base resin exhibited some degree of change in color, surface roughness, and surface hardness in all denture cleansers but was not statistically significant. CONCLUSIONS: The choice of denture cleanser for different denture base resins should be based on the chemistry of resin and the cleanser, denture cleanser concentration and duration of immersion.


Assuntos
Bases de Dentadura , Higienizadores de Dentadura , Humanos , Dureza , Nylons , Análise de Variância
7.
J. oral res. (Impresa) ; 11(6): 1-10, nov. 3, 2022. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1437657

RESUMO

Aim: To assess the effect of different mechanical surface treatments on flexural strength of repaired denture base. Material and Methods: Sixty bar-shaped specimens of heat-polymerized acrylic resin were fabricated, and divided into six groups (n=10). All specimens, except the positive control group (group PC), were sectioned into halves to create a 1-mm clearance. A negative control group with no surface treatment (group NC) was also considered. Other groups underwent different surface treatments: group Laser; treated with erbium: yttrium-aluminum-garnet (Er:YAG) laser, group APA; airborne-particle abrasion (APA), group APA plus Laser; a combination of laser and APA, and group Bur; bur grinding. After measuring surface roughness (Ra) with a profilometer, all sectioned specimens were repaired by auto-polymerizing acrylic resin, and thermocycled afterward. Three-point bending test was performed by a universal testing machine. Data were statistically analyzed (α=0.05). Results: The mean surface roughness of all experimental groups were significantly higher than that of group NC (p<0.05). The mean flexural strength of all groups was significantly lower than that of group PC (p<0.05). Group B had significantly higher flexural strength than the other surface-treated groups (p<0.05). Group Laser had significantly higher flexural strength than groups APA (p=0.043) and APA plus Laser (p=0.023). No significant difference was found between groups APA and APA plus Laser (p=0.684). Conclusion: All surface treatments increased the surface roughness and flexural strength compared with the untreated group. The highest flexural strength was observed in specimens treated by bur grinding and then laser, however, it was still significantly lower than intact specimens.


Objetivo: Evaluar el efecto de diferentes tratamientos superficiales mecánicos sobre la resistencia a la flexión de la base de la prótesis reparada. Material y Métodos: Se fabricaron sesenta especímenes en forma de barra de resina acrílica termo-polimerizada y se dividieron en seis grupos (n=10). Todas las muestras, excepto el grupo de control positivo (grupo PC), se seccionaron en mitades para crear un espacio libre de 1 mm. También se consideró un grupo de control negativo sin tratamiento superficial (grupo NC). Otros grupos se sometieron a diferentes tratamientos superficiales: grupo Láser; tratados con láser de erbio: itrio-aluminio-granate (Er:YAG), grupo APA; abrasión por partículas en el aire (APA), grupo APA más láser; una combinación de láser y APA, y grupo Bur; molienda de fresas. Después de medir la rugosidad de la superficie (Ra) con un perfilómetro, todas las muestras seccionadas se repararon con resina acrílica de autopolimerización y se sometieron a termociclado. La prueba de flexión de tres puntos se realizó con una máquina de prueba universal. Los datos se analizaron estadísticamente (α=0,05). Resultados: La rugosidad superficial media de todos los grupos experimentales fue significativamente mayor que la del grupo NC (p<0,05). La resistencia media a la flexión de todos los grupos fue significativamente menor que la del grupo PC (p<0,05). El grupo B tenía una resistencia a la flexión significativamente mayor que los otros grupos tratados en la superficie (p<0,05). El grupo Láser tuvo una resistencia a la flexión significativamente mayor que los grupos APA (p=0,043) y APA más Láser (p=0,023). No se encontró diferencia significativa entre los grupos APA y APA más Láser (p=0,684). Conclusión: Todos los tratamientos superficiales aumentan la rugosidad de la superficie y la resistencia a la flexión en comparación con el grupo sin tratar. La resistencia a la flexión más alta se observó en las muestras tratadas con fresado y luego con láser; sin embargo, aún era significativamente más baja que las muestras intactas.


Assuntos
Humanos , Resinas Acrílicas/química , Reparação em Dentadura , Polimetil Metacrilato/química , Materiais Dentários/química , Bases de Dentadura , Lasers de Estado Sólido , Metacrilatos/química
8.
Am J Dent ; 35(1): 25-29, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35316589

RESUMO

PURPOSE: To evaluate the effect of cigarette smoking on the color stability and surface roughness of heat-polymerized poly(methylmethacrylate) (PMMA) and computer-aided design and computer-aided manufacturing (CAD-CAM) PMMA denture base materials. METHODS: A total of 40 disc-shaped specimens (diameter 15 mm x thickness 2 mm) were divided into two groups according to their processing technique: Group CC, CAD-CAM PMMA; and Group HP, heat-polymerized PMMA. The specimens were exposed to cigarette smoke with 20 cigarettes daily for 5 days. Before the procedure, the color of the denture base was measured using a spectrophotometer in accordance with the Commission Internationale de I'Eclairage (CIE) color system. The surface roughness (Ra) of each sample was measured five times before and after exposure to smoke using a profilometer, and the mean roughness (Ra) values were calculated. The color change and surface roughness were statistically analyzed (P< 0.05). RESULTS: Greater discoloration was observed in the HP group, whereas the CC group showed clinically acceptable color change. Smoking increased the surface roughness of both denture base materials. However, the HP group had higher mean values than the CC group. CLINICAL SIGNIFICANCE: Denture base materials are susceptible to changes in color and surface roughness due to oral habits such as cigarette smoking. This in vitro study suggested that smoking can exacerbate the color changes and surface roughness of denture base materials, especially in heat-cured acrylic resins.


Assuntos
Fumar Cigarros , Bases de Dentadura , Teste de Materiais , Polimetil Metacrilato , Propriedades de Superfície
11.
Araçatuba; s.n; 2022. 79 p. tab, ilus.
Tese em Português | LILACS, BBO | ID: biblio-1442671

RESUMO

O objetivo desse estudo foi investigar as propriedades de superfície, estabilidade de cor e propriedades mecânicas de resinas acrílicas para base de dentadura do método convencional, processada por micro-ondas, fresada e impressa 3D diante de diferentes tempos de envelhecimento e imersão em bebidas corantes. Além disso, realizar uma revisão sistemática para avaliar e comparar, através de estudos de ensaios clínicos, próteses totais fabricadas pelo método CAD/CAM com fabricadas convencionalmente, em termos de tempo clínico, manutenção, retenção, estabilidade, eficácia mastigatória, satisfação e qualidade de vida. Um total de 480 amostras redondas (10 × 3,3 ± 0,03 mm) foram confeccionadas para avaliação das propriedades de superfície e estabilidade de cor, divididas entre os quatro grupos principais de resinas e subdivididas em quatro tempos de análise (T0, T1, T2 e T3) e bebidas corantes (água, café, vinho e refrigerante cola), resultando um n = 10 para cada subgrupo. Um total de 160 amostras retangulares (64 × 10 × 3,3 ± 0,03 mm) foram confeccionadas para avaliação das propriedades mecânicas, divididas entre os quatro grupos principais de resinas e subdivididas em quatro tempos de análise (T0, T1, T2 e T3), resultando um n = 10 para cada subgrupo. A revisão sistemática seguiu os Itens de Relatório Preferenciais para Revisões Sistemáticas e Meta-Análises (PRISMA) e foi registrada no Registro Prospectivo Internacional de Revisões Sistemáticas (PROSPERO) (CRD42022296907). A busca eletrônica foi realizada nas bases de dados PubMed/MEDLINE, Web of Science e Scopus até dezembro de 2021. A questão formulada para população, intervenção, comparação e resultado (PICO) foi "Pacientes reabilitados com próteses totais com tecnologia CAD/CAM apresentam parâmetros clínicos semelhantes aos pacientes reabilitados com próteses totais convencionais?". A resina fresada apresentou os melhores resultados das propriedades de superfície diante do efeito do envelhecimento, enquanto que a resina impressa 3D apresentou resultados semelhantes as resinas tradicionais. A resina de Impressão 3D apresentou não ter propriedades ópticas adequadas diante do efeito do envelhecimento, enquanto que a resina fresada apresentou as melhores propriedades. As bebidas corantes não alteraram as propriedades de superfície das resinas, entretanto afetaram suas propriedades ópticas, principalmente a resina de impressão 3D e a processada por micro-ondas. A resina de dentadura fresada CAD/CAM apresentou propriedades mecânicas semelhantes as resinas tradicionais, enquanto que a impressa 3D não apresentou propriedades mecânicas adequadas para uso clínico à longo prazo. As próteses do método de fresagem apresentaram melhor desempenho clínico que as próteses convencionais, em termos de qualidade de vida, satisfação, retenção, estabilidade, tempo clínico e custo, enquanto que as de impressão 3D não apresentaram diferenças. Ambos os métodos do CAD/CAM apresentaram não haver diferenças da eficácia mastigatória em relação as próteses convencionais(AU)


The objective of this study was to investigate the surface properties, color stability and mechanical properties of acrylic resins for denture base of the conventional method, processed by microwave, milled and 3D printed in face of different aging times and immersion in coloring drinks. In addition, carry out a systematic review to evaluate and compare, through clinical trial studies, complete dentures manufactured by the CAD/CAM method with those manufactured conventionally, in terms of clinical time, maintenance, retention, stability, masticatory efficiency, satisfaction and quality of life. A total of 480 round samples (10 × 3.3 ± 0.03 mm) were made to evaluate surface properties and color stability, divided among the four main groups of resins and subdivided into four analysis times (T0, T1, T2 and T3) and coloring drinks (water, coffee, wine and cola), resulting in n = 10 for each subgroup. A total of 160 rectangular samples (64 × 10 × 3.3 ± 0.03 mm) were prepared to evaluate the mechanical properties, divided among the four main groups of resins and subdivided into four analysis times (T0, T1, T2 and T3), resulting in n = 10 for each subgroup. The systematic review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and was registered in the International Prospective Registry of Systematic Reviews (PROSPERO) (CRD42022296907). The electronic search was performed in the PubMed/MEDLINE, Web of Science and Scopus databases until December 2021. The question formulated for population, intervention, comparison and result (PICO) was "Patients rehabilitated with complete dentures with CAD/CAM technology present clinical parameters similar to patients rehabilitated with conventional complete dentures?". The milled resin presented the best results of surface properties in the face of aging effect, while the 3D printed resin presented similar results to traditional resins. The 3D Printing resin did not have adequate optical properties due to the aging effect, while the milled resin showed the best properties. Coloring drinks do not change the surface properties of resins, but optical printing solutions, mainly 3D printing resin and microwave-processed resin. The CAD/CAM milled denture resin presented mechanical properties similar to traditional resins, while the 3D printed denture resin did not present adequate mechanical properties for long-term clinical use. The milling method prostheses showed better clinical performance than conventional prostheses, in terms of quality of life, satisfaction, retention, stability, clinical time and cost, while the 3D printing prostheses showed no differences. Both CAD/CAM methods showed no differences in masticatory efficiency in relation to conventional prostheses(AU)


Assuntos
Bases de Dentadura , Fatores de Tempo , Cor , Polimetil Metacrilato , Prótese Total , Resinas , Fenômenos Mecânicos
12.
J. appl. oral sci ; 29: e20200948, 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1340105

RESUMO

Abstract Appropriated denture hygiene is a predictive factor for longevity of rehabilitation treatment and maintenance of the oral mucosal health. Although, disinfectant solutions are commonly used as denture cleansers, the impact of these solutions on acrylic resin-based dentures remain unclear. Objective To evaluate, in vitro, the antibiofilm activity of complete denture hygiene solutions and their effects on physical and mechanical properties of acrylic resin. Methodology For antibiofilm activity measurement acrylic resin specimens were contaminated with Candida albicans, Candida glabrata and Streptococcus mutans. After biofilm growth, the specimens were assigned to the hygiene solutions: Distilled water (Control); 0.2% Sodium hypochlorite (SH); Efferdent Power Clean Crystals (EPC) and 6.25% Ricinus communis (RC). The viability of microorganisms was evaluated by agar plate counts. In parallel, physical, and mechanical properties of the acrylic resin were evaluated after simulating a 5-year period of daily immersion in the previously mentioned solutions. The changes in surface roughness, color, microhardness, flexural strength, impact strength, sorption and solubility were evaluated. Data were compared by ANOVA followed by the Tukey test or Kruskal-Wallis followed by the Dunn test depending on the distribution (α=0.05). Results Regarding antibiofilm action, SH eliminated all microorganisms while EPC and RC exhibited moderate action against S. mutans (p=0.001) and C. glabrata (p<0.001), respectively. Relative to effects on the physical and mechanical properties of the acrylic resin, RC led to higher values of color change (p=0.030), hardness (p<0.001), surface roughness (p=0.006) and flexural strength (p<0.001). Moreover, RC induced the highest values of changes in solubility (p<0.001). EPC promoted greater changes in surface morphology, whereas immersion in SH retained the initial appearance of the acrylic resin surface. All hygiene solutions reduced the impact strength (p<0.05). Conclusion SH presented the most effective antibiofilm activity. In addition, changes on properties were observed after immersion in RC, which were considered within acceptable limits.


Assuntos
Resinas Acrílicas , Higienizadores de Dentadura/farmacologia , Propriedades de Superfície , Teste de Materiais , Higiene , Biofilmes , Bases de Dentadura , Prótese Total
13.
J. appl. oral sci ; 29: e20200865, 2021. graf
Artigo em Inglês | LILACS | ID: biblio-1286916

RESUMO

Abstract Denture stomatitis is the most frequent oral lesion in removable prosthesis wearers, with high recurrence rates and a complex treatment. Objective This study describes a protocol to obtain and to contaminate a palatal device with Candida albicans biofilm that could be used for an animal model of denture stomatitis. Methodology Acrylic resin devices (N=41) were obtained from impressions of the palates of Wistar rats with individual trays and polyether. The efficacy of microwave irradiation (MW), ultraviolet light (UV), or ultrasonic bath (US) was assessed by colony viability and spectrophotometric analyses (n=5) in order to select the most appropriate method for sterilizing the devices. Then, different devices (n=5) were contaminated with C. albicans and evaluated by CFU/mL determination, scanning electron microscopy, and laser confocal microscopy. Device stabilization was assessed with either autopolymerizing acrylic resins or a self-adhesive resin cement (n=2). The spectrophotometric data were analyzed by one-way ANOVA followed by the Tukey's HSD post-hoc test (α=0.05). Results MW was the only method capable of sterilizing the devices, and the contamination protocol developed a mature and viable C. albicans biofilm (~1.2 x 106 CFU/mL). The self-adhesive resin cement was the best stabilization material. Conclusions This acrylic resin palatal device was designed to be similar to the clinical situation of contaminated prostheses, with easy manufacturing and handling, effective stabilization, and satisfactory contamination. Thus, the acrylic device can be a valuable tool in the development of denture stomatitis in rats.


Assuntos
Animais , Ratos , Estomatite sob Prótese , Candida albicans , Palato , Resinas Acrílicas , Ratos Wistar , Biofilmes , Bases de Dentadura
14.
J. appl. oral sci ; 29: e20200448, 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1154618

RESUMO

Abstract Denture adhesives need complete removal due to their frequent replacement. Objective Our study investigates the removal of denture adhesives from denture base materials, using different methods. Methodology PMMA and Polyamide denture base materials were used to fabricate 120 samples (15×15×1.5mm). One side of the samples was left as processed and the other polished with a usual procedure, hydrated for 24 h, dried, and weighted. They received 0.2 g of three adhesive creams on their unpolished surface (Corega, Olivafix, Fittydent), pressed on polysulfide material, stored under 37°C and 95% rel. humidity for 1 h and 60 of them, following their separation from polysulfide base, brushed under running water, whereas the rest inserted in a cleanser bath (Fittydent Super) for 5 min. The samples were dried and inserted in the oven (37°C) for additional 10 min and weighted again. Roughness tests of denture materials and light microscopy of adhesives creams were also used to evaluate the materials. Time lapse images of spayed with water adhesives on PMMA base were also taken to evaluate the volumetric changes of adhesives. Weight data before and after adhesive removal, indicating the amount of remaining adhesive, were statistically analyzed using Welch's ANOVA and Games-Howell multiple comparisons tests at α=0.05 level of significance. Results Roughness of Polyamide was higher than PMMA and Fittydent showed greater volumetric changes than the others. Significant differences (p<0.05), were found between PMMA and Polyamide bases, between Olivafix and Fittydent adhesives, and between brushing and cleansing methods but only for PMMA-Olivafix combination. Conclusions Adhesives showed a stronger adherence to PMMA surface, and Fittydent was the most difficult to be removed. Removal methods were not effective for all adhesives or denture base materials. These indicate that removal methods, adhesive type and denture base material are all playing a significant role in the removal of adhesives from denture surfaces.


Assuntos
Bases de Dentadura , Nylons , Propriedades de Superfície , Teste de Materiais , Adesivos , Polimetil Metacrilato
15.
Rev. Fac. Odontol. Porto Alegre ; 61(2): 39-49, jul-dez. 2020.
Artigo em Inglês | LILACS, BBO | ID: biblio-1281697

RESUMO

Background: The purposes of this study were: (1) to formulate polyhexamethylene guanidine hydrochloride (PHMGH) solutions at different concentrations; (2) to evaluate their antifungal activity against a mature biofilm of Candida albicans on acrylic resins; (3) to evaluate possible effects on acrylic resins flexural strength and surface roughness. Methods: PHMGH solutions were formulated with distilled water and 0.125, 0.250, or 0.5 wt.% of PHMGH. One group without PHMGH was used as control. For antifungal activity analysis, acrylic resin specimens were contaminated with C. albicans. Specimens were immersed in PHMGH solutions or distilled water for 5 or 10 min. Ultimate flexural strength and surface roughness of acrylic resins were evaluated. Results: All PHMGH solutions at 5 or 10 min showed antifungal activity compared to the control group (p<0.05). The group with 0.5 wt.% of PHMGH showed no countable colonies regardless of the time of contact with the acrylic resins. After 10 min, all PHMGH solutions had antifungal effect without differences from 0.125 to 0.5 wt.% of PHMGH. All groups showed high flexural strength after contact with the solutions compatible with ISO 20795-1:2013 recommendation. The values of surface roughness always remained low, from 0.01 to 0.04 µm for all groups. Conclusion: Within the limitations of this study, it was concluded that the use of a solution composed by distilled water and 0.5 wt.% of PHMGH for 5 min was effective as a disinfectant agent against mature biofilm of C. albicans , maintaining acceptable roughness and flexural strength.


Antecedentes: Os objetivos deste estudo foram: (1) formular soluções de cloridrato de polihexametileno guanidina (PHM-GH) em diferentes concentrações; (2) avaliar sua atividade antifúngica contra biofilme maduro de Candida albicans em resinas acrílicas; (3) avaliar efeitos na resistência à flexão e rugosidade da superfície. Métodos: Soluções de PHMGH foram formuladas com água destilada e 0,125, 0,250 ou 0,5% em peso de PHMGH. Um grupo sem PHMGH foi usado como controle. Para análise da atividade antifúngica, amostras de resina acrílica foram contaminadas com C. albicans, e imersas em soluções de PHMGH ou água destilada por 5 ou 10 min. Resistência à flexão final e rugosidade da superfície foram avaliadas. Resultados: Todas as soluções de PHMGH aos 5 ou 10 minutos apresentaram atividade antifúngica em comparação ao grupo controle (p <0,05). O grupo com 0,5% em peso de PHMGH não mostrou colônias contáveis, independentemente do tempo. Após 10 minutos, todas as soluções de PHMGH tiveram efeito antifúngico sem diferenças de 0,125 a 0,5% em peso de PHM-GH. Os grupos apresentaram alta resistência à flexão após o contato com as soluções compatíveis com a recomendação ISO 20795-1: 2013. Os valores de rugosidade da superfície permaneceram baixos, de 0,01 a 0,04 µm para todos os grupos. Conclusão: Dentro das limitações deste estudo, concluiu-se que o uso de uma solução composta por água destilada e 0,5% em massa de PHMGH por 5 min foi eficaz como agente desinfetante contra o biofilme maduro de C. albicans, mantendo rugosidade e resistência à flexão aceitáveis.


Assuntos
Humanos , Resinas Acrílicas , Guanidina , Bases de Dentadura , Antifúngicos , Propriedades de Superfície , Técnicas In Vitro , Teste de Materiais , Resistência à Flexão
16.
Dental press j. orthod. (Impr.) ; 25(6): 43-48, Nov.-Dec. 2020. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-1154053

RESUMO

ABSTRACT Objective: To evaluate different concentrations of Galla chinensis extract (GCE) added to poly(methyl methacrylate) (PMMA), which is widely used for fabrication of removable orthodontic appliances, regarding the effectiveness of this herbal extract on antimicrobial effect and flexural strength of PMMA. Methods: Acrylic resin samples containing 0.4%, 0.8% and 1.6% GCE were prepared. Flexural strength was investigated via three-point flexural strength test for the 15 acrylic resin blocks of each concentration. Disk diffusion test was used to evaluate antibacterial effects of incorporating the same concentrations of GCE into acrylic resin. All these three groups were compared with the control group, with no added GCE, regarding flexural strength and antibacterial properties. Results: Comparison of flexural strength between the three study groups and the control group showed significant differences between the groups (P=0.018). However, there was no significant difference between the groups containing GCE. There were significant differences in antimicrobial activity between the four groups (P=0.026). Conclusion: Within the limitations of this study, it is suggested that incorporation of GCE into PMMA would be beneficial for antimicrobial activity and flexural strength of PMMA, but further studies on other physical properties and antimicrobial effects on other bacterial strain would be beneficial prior to clinical investigations.


RESUMO Objetivo: Avaliar se diferentes concentrações de extrato de Galla chinensis (EGC) adicionado ao polimetilmetacrilato (PMMA), que é amplamente utilizado para a fabricação de aparelhos ortodônticos removíveis, interferem no efeito antimicrobiano desse extrato e na resistência à flexão do PMMA. Métodos: Foram preparadas amostras de resina acrílica com concentrações de 0,4%, 0,8% e 1,6% de EGC. Para a avaliação da resistência à flexão, utilizou-se o teste de flexão em três pontos para as 15 amostras de resina em cada concentração. O teste de disco-difusão foi utilizado para avaliar os efeitos antibacterianos da incorporação das mesmas concentrações de EGC na resina acrílica. Esses três grupos foram comparados ao grupo controle, sem adição do EGC, em relação à resistência à flexão e quanto às propriedades antimicrobianas. Resultados: As comparações dos três grupos com o grupo controle mostraram diferenças significativas (p=0,018) para a resistência à flexão. Entretanto, não houve diferença significativa entre os grupos contendo EGC. Foram encontradas diferenças significativas na atividade antimicrobiana entre os quatro grupos (p=0,026). Conclusão: Dentro das limitações desse estudo, parece que a incorporação de EGC no PMMA seria benéfica para a atividade antimicrobiana e a resistência à flexão do PMMA. Porém, estudos adicionais sobre outras propriedades físicas e sobre os efeitos antimicrobianos contra diferentes cepas de bactérias seriam interessantes antes de se fazer pesquisas clínicas.


Assuntos
Resinas Acrílicas , Bases de Dentadura , Resistência à Flexão , Anti-Infecciosos , Antibacterianos/farmacologia , Teste de Materiais , Extratos Vegetais/farmacologia
17.
Gen Dent ; 68(6): 56-59, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33136047

RESUMO

The aim of this study was to evaluate the flexural strength and Knoop microhardness of the polymethyl methacrylate (PMMA) used in dental prostheses after receiving therapeutic radiation doses of 50 and 70 Gy. Thirty-six acrylic resin plates measuring 65.0 × 10.0 × 3.3 mm were fabricated and polymerized using a microwave. The specimens were randomly divided into 3 groups (n = 12): group 1, which received no radiation; group 2, which received 1 fractioned dose of 2 Gy per day, 5 days per week, for 5 weeks, totaling 50 Gy; and group 3, which received 1 fractioned dose of 2 Gy per day, 5 days per week, for 7 weeks, totaling 70 Gy. All specimens remained in ballistic gel at a temperature of 37°C throughout the study. Afterward, the specimens underwent flexural strength and Knoop microhardness tests. All data were analyzed using analysis of variance and Tukey post hoc test (P < 0.05). For flexural strength, there was a statistically significant difference between groups 1 and 2 (P = 0.012) and between groups 1 and 3 (P = 0.048). For Knoop microhardness, there was a difference between groups 1 and 2 (P = 0.001) and between groups 1 and 3 (P = 0.006). For both flexural strength and microhardness, groups 2 and 3 showed greater values than group 1. Therapeutic radiation doses of 50 and 70 Gy increased the flexural strength and Knoop microhardness of PMMA used in dental prostheses.


Assuntos
Bases de Dentadura , Polimetil Metacrilato , Resinas Acrílicas , Materiais Dentários , Teste de Materiais , Maleabilidade , Doses de Radiação , Propriedades de Superfície
18.
Braz. dent. j ; 31(5): 523-531, Sept.-Oct. 2020. tab
Artigo em Inglês | LILACS, BBO | ID: biblio-1132329

RESUMO

Abstract Thiourethane additives have been shown to improve properties in several dental polymer applications. The aim of this study was to verify the effect of the addition of thiourethane oligomers and acrylamide or isobornyl-based plasticizers on the physical properties of the denture base acrylic resin polymerized with microwaves. Thiourethane oligomer (TU) was synthetized and added to microwaved acrylic resin in proportions varying between 3 and 14 wt%. Separate experimental groups included the addition of dimethyl acrylamide (DMAM) and isobornyl methacrylate as plasticizers, at concentrations varying from 5 to 20 wt%. Samples were polymerized using microwave energy at 500 Watts for 3 min, deflasked at room temperature, stored in water at 37 °C for 24 h, and evaluated for: linear dimensional change, gloss, Knoop hardness, surface roughness, impact strength, yield strength, elastic modulus, toughness, yield strength, viscosity, glass transition temperature and network heterogeneity, and water sorption/solubility. Data were analyzed with ANOVA/Tukey's post-hoc test (a=5%). The addition of TU led to properties that were similar or worse than the materials to which it was not added, except for dimensional stability. The impact on properties was statistically significant for all materials above 20% addition of TU. The addition of DMAM at 5 wt% or isobornyl methacrylate at 10 wt% improved yield strength and modulus, but increased water sorption and solubility. Except for dimensional stability, the addition of thiourethane oligomers to acrylic denture base materials compromised most tested properties. The use of DMAM and isobornyl methacrylate improved properties for selected compositions.


Resumo Aditivos de tiouretano demonstraram melhorar propriedades de polímeros em diversas aplicações. O objetivo deste estudo foi verificar o efeito da adição de oligômeros de tiouretano, monômeros de acrilamida ou baseados em funcionalidade isobornil na propriedades físicas de bases de dentadura de acrílico polimerizadas em micro-ondas. O oligômero de tiouretano (TU) foi sintetizado e adicionado à resina acrílica em proporções variando de 3 a 14% em peso. Dimetil acrilamida (DMAM) e isobornil metacrilato (IBMA) foram adicionados em formulações separadas como plastificantes em concentrações variando de 5 a 20% em peso. As amostras foram polimerizadas usando energia de micro-ondas (500 Watts oor 3 min), desincluídas da mufla a temperature ambiente, armazenadas em água a 37°C por 24 h, e submetidas aos testes de: alteração dimensional linear, brilho, dureza Knoop, rugosidade superficial, resistência ao impacto, tensão normal de escoamento, módulo de elasticidade, tenacidade, viscosidade, temperatura de transição vítrea e heterogeneidade da rede polimérica, além de sorção de água e solubilidade. Os dados foram analisados com ANOVA e teste de Tukey (a=5%). A adição de TU não afetou ou diminuiu todas as propriedades, exceto pela estabilidade dimensional. O impacto nas propriedades foi estatisticamente significante para todos os materiais em concentrações acima de 20% de TU. Isso pode ser explicado por um encurtamento das cadeias e diminuição do empacotamento das cadeias lineares do PMMA. A adição de 5% de DMAM ou 10% de isobornil metacrilato melhoraram a tensão de escoamento e o módulo, mas aumentaram a sorção de água e solubilidade. Exceto pela estabilidade dimensional, a adição de oligômeros de tiouretano à bases de dentatura compostas por resina acrílica prejudicou todas a propriedades testadas. O uso de DMAM e isobornil metacrilato melhorou as propriedades para composições selecionadas.


Assuntos
Bases de Dentadura , Micro-Ondas , Propriedades de Superfície , Teste de Materiais , Polimetil Metacrilato , Materiais Dentários , Polimerização
19.
Braz Oral Res ; 34: e050, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32578760

RESUMO

Candida infection is an important cause of morbidity and mortality in immunocompromised patients. The increase in its incidence has been associated with resistance to antimicrobial therapy and biofilm formation. The aim of this study was to evaluate the efficacy of tea tree oil (TTO) and its main component - terpinen-4-ol - against resistant Candida albicans strains (genotypes A and B) identified by molecular typing and against C. albicans ATCC 90028 and SC 5314 reference strains in planktonic and biofilm cultures. The minimum inhibitory concentration, minimum fungicidal concentration, and rate of biofilm development were used to evaluate antifungal activity. Results were obtained from analysis of the biofilm using the cell proliferation assay 2,3-Bis-(2-methoxy-4-nitro-5-sulfophenyl)-2H-tetrazolium-5-carboxanilide (XTT) and confocal laser scanning microscopy (CLSM). Terpinen-4-ol and TTO inhibited C. albicans growth. CLSM confirmed that 17.92 mg/mL of TTO and 8.86 mg/mL of terpinen-4-ol applied for 60 s (rinse simulation) interfered with biofilm formation. Hence, this in vitro study revealed that natural substances such as TTO and terpinen-4-ol present promising results for the treatment of oral candidiasis.


Assuntos
Biofilmes/efeitos dos fármacos , Candida albicans/efeitos dos fármacos , Óleo de Melaleuca/farmacologia , Terpenos/farmacologia , Resinas Acrílicas , Análise de Variância , Antifúngicos/farmacologia , Biofilmes/crescimento & desenvolvimento , Candida albicans/crescimento & desenvolvimento , Bases de Dentadura/microbiologia , Testes de Sensibilidade Microbiana , Microscopia Confocal , Valores de Referência , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Óleo de Melaleuca/química , Terpenos/química
20.
J. oral res. (Impresa) ; 9(2): 84-85, abr. 30, 2020. ilus
Artigo em Inglês | LILACS | ID: biblio-1151829
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA