Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 177
Filtrar
1.
Dent Mater ; 40(6): 941-950, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38719709

RESUMO

OBJECTIVE: Bisphenol A glycidyl methacrylate (Bis-GMA) is of great importance for dental materials as the preferred monomer. However, the presence of bisphenol-A (BPA) core in Bis-GMA structure causes potential concerns since it is associated with endocrine diseases, developmental abnormalities, and cancer lesions. Therefore, it is desirable to develop an alternative replacement for Bis-GMA and explore the intrinsic relationship between monomer structure and resin properties. METHODS: Here, the betulin maleic diester derivative (MABet) was synthesized by a facile esterification reaction using plant-derived betulin and maleic anhydride as raw materials. Its chemical structure was confirmed by 1H and 13C NMR spectra, FT-IR spectra, and HR-MS, respectively. The as-synthesized MABet was then used as polymerizable comonomer to partially or completely substitute Bis-GMA in a 50:50 Bis-GMA: TEGDMA resin (5B5T) to formulate dental restorative resins. These were then determined for the viscosity behavior, light transmittance, real-time degree of conversion, residual monomers, mechanical performance, cytotoxicity, and antibacterial activity against Streptococcus mutans (S. mutans) in detail. RESULTS: Among all experimental resins, increasing the MABet concentration to 50 wt% made the resultant 5MABet5T resin have a maximum in viscosity and appear dark yellowish after polymerization. In contrast, the 1MABet4B5T resin with 10 wt% MABet possessed comparable shear viscosity and polymerization conversion (46.6 ± 1.0% in 60 s), higher flexural and compressive strength (89.7 ± 7.8 MPa; 345.5 ± 14.4 MPa) to those of the 5B5T control (48.5 ± 0.6%; 65.7 ± 6.7 MPa; 223.8 ± 57.1 MPa). This optimal resin also had significantly lower S. mutans colony counts (0.35 ×108 CFU/mL) than 5B5T (7.6 ×108 CFU/mL) without affecting cytocompatibility. SIGNIFICANCE: Introducing plant-derived polymerizable MABet monomer into dental restorative resins is an effective strategy for producing antibacterial dental materials with superior physicochemical property.


Assuntos
Antibacterianos , Bis-Fenol A-Glicidil Metacrilato , Teste de Materiais , Streptococcus mutans , Triterpenos , Antibacterianos/farmacologia , Antibacterianos/química , Antibacterianos/síntese química , Triterpenos/química , Triterpenos/farmacologia , Streptococcus mutans/efeitos dos fármacos , Bis-Fenol A-Glicidil Metacrilato/química , Viscosidade , Materiais Dentários/química , Materiais Dentários/farmacologia , Materiais Dentários/síntese química , Polimerização , Ácidos Polimetacrílicos/química , Ácidos Polimetacrílicos/farmacologia , Resinas Compostas/química , Resinas Compostas/síntese química , Resinas Compostas/farmacologia , Polietilenoglicóis/química , Espectroscopia de Infravermelho com Transformada de Fourier , Ácido Betulínico
2.
Dent Mater ; 40(5): 837-841, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38570242

RESUMO

OBJECTIVES: to assess the impact of universal adhesives, cured with single-peak and polywave LEDs, on the metabolic activity and cytokine release of human dental pulp stem cells (hDPSCs). In addition, analyze the degree of conversion (DC) of the adhesives cured with the different LEDs. METHODS: Discs (5 mm diameter, 1 mm thick) were prepared using three universal adhesives: Single Bond Universal (SBU, 3 M ESPE), Optibond Universal (OBU, Kerr), and Zipbond Universal (ZBU, SDI). These discs were cured for 40 s using a single-peak (DeepCure, 3 M ESPE) or a polywave light-emmiting diode (LED) curing unit (Valo Grand, Ultradent). After 24 h, the specimens were placed in 24-well culture plates, each containing 1 mL of culture medium for 24 h. hDPSCs (1.8 ×104) were seeded in 96-well plates and allowed to grow for 24 h. Subsequently, the cells were exposed to the extracts (culture medium containing eluates from the adhesive discs) for an additional 24 h. Cells not exposed to the extracts were used as a control group. The mitochondrial metabolism was assessed using the MTT assay and the cytokine release evaluated through MAGPIX. The degree of conversion of the adhesives was analyzed using FTIR (n = 5). The results were analyzed by ANOVA two-way and Tukey's test. RESULTS: OBU and ZBU eluates caused a statistically significant reduction in mitochondrial metabolism, regardless of the LED used, indicating their cytotoxicity. In contrast, SBU did not significantly affect the MTT results, resembling the control group. A higher release of cytokines IL-1, IL-6, IL-10, and TNF-α were found in association to ZBU. SBU, on the other hand, increased the release of IL-8. OBU did not influenced the cytokine release. SBU presented the higher DC, while OBU and ZBU had similar DC, lower than SBU. SIGNIFICANCE: In conclusion, universal adhesives exhibit toxicity towards hDPSCs, but the extent of toxicity varies depending on the adhesive material. ZBU was associated with increased cytokine release, particularly pro-inflammatory mediators, from hDPSCs. The different LEDs did not influenced the cytotoxicity of the evaluated adhesives.


Assuntos
Lâmpadas de Polimerização Dentária , Citocinas , Cimentos Dentários , Polpa Dentária , Teste de Materiais , Células-Tronco , Humanos , Polpa Dentária/citologia , Citocinas/metabolismo , Cimentos Dentários/química , Cimentos Dentários/farmacologia , Cura Luminosa de Adesivos Dentários , Cimentos de Resina/química , Cimentos de Resina/toxicidade , Células Cultivadas , Bis-Fenol A-Glicidil Metacrilato/toxicidade , Bis-Fenol A-Glicidil Metacrilato/química
3.
Dent Mater ; 38(2): 281-293, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34955233

RESUMO

OBJECTIVE: Although bisphenol Aglycidyl methacrylate (Bis-GMA) are widely used in the dental composite, its raw materials include the petroleum-based product bisphenol A (BPA) with high estrogenic activity (EA). In this study, two new BPA-free dimethacrylate monomers from bio-based material creosol were synthesized and evaluated. METHODS: The renewable bisphenol monomer 5, 5'-methylenedicreosol (BCF) was prepared from bio-based material creosol. By the human breast cancer cells (MCF-7 cells) proliferation assay, a risk assessment of BCF was performed to determine if BCF possessed reduced EA in comparison to BPA. Then, the novel monomers 5, 5'-methylenedicreosol diglycidyl ether diacrylate (BCF-EA) and 5, 5'-methylenedicreosol diglycidyl ether dimethacrylate (BCF-GMA) were synthesized from BCF with epichlorohydrin and (meth)acrylate. All products were investigated by 1H NMR and FT-IR spectra. The control resin was a mixture based on Bis-GMA and tri(ethyleneglycol) dimethacrylate (TEGDMA) with a weight ratio of 5:5 (5B5T). Similarly, experimental resin matrix was a mixture based on BCF-EA/TEGDMA (5E5T) and BCF-GMA/TEGDMA (5G5T). And their corresponding composites were then prepared with corresponding resin matrices and hybrid SiO2 (5E5TC, 5G5TC and 5B5TC). The properties of these composites were investigated according to the standard or referenced methods. Each sample was evaluated for double bond conversion (DC), shrinkage stress (SS) and volumetric polymerization shrinkage (VS). Water sorption (WS), water solubility (SL), mechanical properties and cytotoxicity were also measured. RESULTS: 1H NMR and FT-IR spectra confirmed the chemical structure of each monomer. EA test revealed that bio-based bisphenol monomer BCF as the precursor of BCF-EA and BCF-GMA showed lower EA than BPA. Cured resin matrix: Both 5E5T and 5G5T had nearly the same DC (p < 0.05), which was higher than 5B5T (p < 0.05); 5E5T and 5G5T had lower VS, SL and cytotoxicity than 5B5T (p < 0.05); mechanical properties of 5E5T and 5G5T were all better than those of 5B5T (p < 0.05). Cured composite: There was no significant difference in conversion (p < 0.05); 5E5TC and 5G5TC had significantly lower VS (p < 0.05); WS of 5E5TC and 5G5TC were similar (p < 0.05), but higher compared to 5B5TC (p < 0.05); 5E5TC and 5G5TC had the deeper depth of cure (p > 0.05); before water immersion, there was no significant difference in flexural strength between 5E5TC and 5G5TC (p > 0.05), and higher than 5B5TC (p < 0.05); 5E5TC and 5G5TC showed less cytotoxicity than 5B5TC (p < 0.05). SIGNIFICANCE: The new BPA-free di(meth)acrylates are promising photocurable dental monomers owning to bio-based raw material, high degree of conversion coupled with low curing shrinkage and good mechanical properties. Therefore, BCF-EA and BCF-GMA has a potential to be used as the substitution for Bis-GMA to prepare Bis-GMA-free dental composite.


Assuntos
Resinas Compostas , Dióxido de Silício , Compostos Benzidrílicos , Bis-Fenol A-Glicidil Metacrilato/química , Resinas Compostas/química , Humanos , Teste de Materiais , Metacrilatos/química , Fenóis , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Espectroscopia de Infravermelho com Transformada de Fourier
4.
Biomed Res Int ; 2020: 2327034, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32775410

RESUMO

The polarization of macrophages and its anti-inflammatory and proinflammatory properties play a significant role in host response after implant placement to determine the outcome of osseointegration and long-term survival. In the previous study, we immobilized an antimicrobial peptide, GL13K, onto titanium surfaces to provide immune regulation property. In the herein presented study, we aimed at investigating whether GL13K immobilized titanium surface could improve osteogenesis and reduce the inflammatory reaction around the biomaterials by altering macrophage response. We evaluated the cell proliferation of the different phenotypes of macrophages seeded in GL13K-coated titanium surface, which indicated an inhibition of M1 macrophages and a good cytocompatibility to M2 macrophages. Then, we measured the inflammatory and anti-inflammatory activity of the M1 and M2 macrophages seeded on the GL13K-coated titanium surfaces. The results of the enzyme-linked immunosorbent assay and quantitative reverse transcription-polymerase chain reaction showed that the group with the GL13K modified surface had a downregulation in the expression level of the tumor necrosis factor-α and interleukin-1ß in M1 macrophages and an upregulation of IL-10 and transforming growth factor-ß3 (TGF-ß3) levels in M2 macrophages. This study demonstrated that the GL13K modified titanium surfaces can regulate macrophages' polarization and the expression of inflammatory and anti-inflammatory effects, reducing the effects of the inflammatory process, which may promote the process of bone regeneration and osseointegration.


Assuntos
Materiais Revestidos Biocompatíveis , Macrófagos/metabolismo , Oligopeptídeos , Titânio , Animais , Bis-Fenol A-Glicidil Metacrilato/química , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Inflamação/metabolismo , Camundongos , Oligopeptídeos/química , Oligopeptídeos/farmacologia , Células RAW 264.7 , Titânio/química , Titânio/farmacologia
5.
Int J Mol Sci ; 21(11)2020 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-32486393

RESUMO

Dental universal adhesives are considered an useful tool in modern dentistry as they can be used in different etching techniques, allow for simplified protocol and provide sufficient bond strength. However, there is still no consensus as to their toxicity towards pulp. Thus, the present study aimed to evaluate the cytotoxicity and genotoxicity of three universal adhesives: OptiBond Universal, Prime&Bond Universal and Adhese in an in vitro experimental model, monocyte/macrophage cell line SC (ATCC CRL-9855). The cytotoxicity was measured by means of XTT assay, whereas the genotoxicity (comet assay) was evaluated based on the percentage of DNA present in the comet tail. Furthermore, the ability of the adhesives to induce apoptosis was analyzed using flow cytometry (FC) with the FITC annexin V/propidium iodide (PI) double staining. The analysis of the cell cycle progression was performed with FC using PI staining. OptiBond Universal presented significant, while Prime&Bond Universal and Adhese Universal had minimal cytotoxicity and genotoxicity towards human SC cells. Moreover, only OptiBond Universal increased the level of apoptosis in SC cell line. None of the adhesives showed significant cell cycle arrest, as revealed by FC analysis. Due to substantial differences in toxicity in in vitro studies of dental adhesives, there is a great need for further research in order to establish more reliable test protocols allowing for standardized methodology.


Assuntos
Resinas Acrílicas/química , Bis-Fenol A-Glicidil Metacrilato/química , Cimentos Dentários/química , Ácidos Polimetacrílicos/química , Cimentos de Resina/química , Apoptose , Ciclo Celular , Linhagem Celular , Colorimetria , Ensaio Cometa , Citotoxinas , Dano ao DNA , Colagem Dentária , Dentina , Humanos , Técnicas In Vitro , Macrófagos/efeitos dos fármacos , Teste de Materiais , Monócitos/efeitos dos fármacos , Mutagênicos
6.
Braz Oral Res ; 34: e005, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32022224

RESUMO

The purpose of this study was to evaluate the effect of ionizing radiation from high energy X-ray on fluoride release, surface roughness, flexural strength, and surface chemical composition of the materials. The study groups comprised five different restorative materials: Beautifil II, GCP Glass Fill, Amalgomer CR, Zirconomer, and Fuji IX GP. Twenty disk-shaped specimens (8x2 mm) for fluoride release and 20 bar-shaped specimens (25 x 2x 2 mm) for flexural strength were prepared from each material. Each material group was divided into two subgroups: irradiated (IR) and non-irradiated (Non-IR). The specimens from IR groups were irradiated with 1.8 Gy/day for 39 days (total IR = 70.2 Gy). The amount of fluoride released into deionized water was measured using a fluoride ion-selective electrode and ion analyzer after 24 hours and on days 2, 3, 7, 15, 21, 28, 35, and 39 (n = 10). The flexural strength was evaluated using the three-point bending test (n = 10). After the period of measurement of fluoride release, seven specimens (n = 7) from each group were randomly selected to evaluate surface roughness using AFM and one specimen was randomly selected for the SEM and EDS analyses. Data were analyzed with two-way ANOVA and Tukey tests (p = 0.05). The irradiation significantly increased fluoride release and surface roughness for Amalgomer CR and Zirconomer groups (p < 0.05). No significant change in flexural strength of the materials was observed after irradiation (p > 0.05). The ionizing radiation altered the amount of fluoride release and surface roughness of only Amalgomer CR and Zirconomer. The effect could be related to the chemical compositions of materials.


Assuntos
Apatitas/efeitos da radiação , Bis-Fenol A-Glicidil Metacrilato/efeitos da radiação , Resinas Compostas/efeitos da radiação , Fluoretos/química , Cimentos de Ionômeros de Vidro/efeitos da radiação , Radiação Ionizante , Zircônio/efeitos da radiação , Análise de Variância , Apatitas/química , Bis-Fenol A-Glicidil Metacrilato/química , Resinas Compostas/química , Resistência à Flexão , Cimentos de Ionômeros de Vidro/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Valores de Referência , Reprodutibilidade dos Testes , Espectrometria por Raios X , Estatísticas não Paramétricas , Propriedades de Superfície/efeitos da radiação , Fatores de Tempo , Zircônio/química
7.
Braz. oral res. (Online) ; 34: e005, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1055521

RESUMO

Abstract The purpose of this study was to evaluate the effect of ionizing radiation from high energy X-ray on fluoride release, surface roughness, flexural strength, and surface chemical composition of the materials. The study groups comprised five different restorative materials: Beautifil II, GCP Glass Fill, Amalgomer CR, Zirconomer, and Fuji IX GP. Twenty disk-shaped specimens (8x2 mm) for fluoride release and 20 bar-shaped specimens (25 x 2x 2 mm) for flexural strength were prepared from each material. Each material group was divided into two subgroups: irradiated (IR) and non-irradiated (Non-IR). The specimens from IR groups were irradiated with 1.8 Gy/day for 39 days (total IR = 70.2 Gy). The amount of fluoride released into deionized water was measured using a fluoride ion-selective electrode and ion analyzer after 24 hours and on days 2, 3, 7, 15, 21, 28, 35, and 39 (n = 10). The flexural strength was evaluated using the three-point bending test (n = 10). After the period of measurement of fluoride release, seven specimens (n = 7) from each group were randomly selected to evaluate surface roughness using AFM and one specimen was randomly selected for the SEM and EDS analyses. Data were analyzed with two-way ANOVA and Tukey tests (p = 0.05). The irradiation significantly increased fluoride release and surface roughness for Amalgomer CR and Zirconomer groups (p < 0.05). No significant change in flexural strength of the materials was observed after irradiation (p > 0.05). The ionizing radiation altered the amount of fluoride release and surface roughness of only Amalgomer CR and Zirconomer. The effect could be related to the chemical compositions of materials.


Assuntos
Apatitas/efeitos da radiação , Radiação Ionizante , Bis-Fenol A-Glicidil Metacrilato/efeitos da radiação , Resinas Compostas/efeitos da radiação , Fluoretos/química , Cimentos de Ionômeros de Vidro/efeitos da radiação , Apatitas/química , Valores de Referência , Espectrometria por Raios X , Propriedades de Superfície/efeitos da radiação , Fatores de Tempo , Zircônio/efeitos da radiação , Zircônio/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Análise de Variância , Bis-Fenol A-Glicidil Metacrilato/química , Estatísticas não Paramétricas , Resinas Compostas/química , Resistência à Flexão , Cimentos de Ionômeros de Vidro/química
8.
J. appl. oral sci ; 27: e20180111, 2019. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-975872

RESUMO

Abstract Several anti-proteolytic dentin therapies are being exhaustively studied in an attempt to reduce dentin bond degradation and improve clinical performance and longevity of adhesive restorations. Objectives This study assessed the effect of epigallocatechin-3-gallate (EGCG) on long-term bond strength when incorporated into adhesives. Material and Methods Adhesive systems were formulated with EGCG concentrations of 0 wt%: (no EGCG; control); 0.5 wt% EGCG; 1.0 wt% EGCG, and 1.5 wt% EGCG. Flexural strength (FS), modulus of elasticity (ME), modulus of resilience (MR), compressive strength (CS), degree of conversion (DC), polymerization shrinkage (PS), percentage of water sorption (%WS), percentage of water solubility (%WL) and cytotoxicity properties were tested. Dentin microtensile bond strength (µTBS) was evaluated after 24 h and again after 6 months of water storage. The adhesive interface was analyzed using scanning electron microscopy (SEM). Results No significant differences were found among the groups in terms of FS, ME, MR, CS and PS. EGCG-doped adhesives increased the DC relative to the control group. EGCG concentrations of 1.0 wt% and 0.5 wt% decreased the WS of adhesives. WL decreased in all cases in which EGCG was added to adhesives, regardless of the concentration. EGCG concentrations of 1.0 wt% and 0.5 wt% reduced cytotoxicity. EGCG concentrations of 1.0 wt% and 0.5 wt% preserved µTBS after 6 months of storage, while 1.5 wt% EGCG significantly decreased µTBS. SEM: the integrity of the hybrid layer was maintained in the 0.5 wt% and 1.0 wt% EGCG groups. Conclusion EGCG concentrations of 1.0 wt% and 0.5 wt% showed better biological and mechanical performance, preserved bond strength and adhesive interface, and reduced cytotoxicity.


Assuntos
Humanos , Catequina/análogos & derivados , Adesivos Dentinários/química , Bis-Fenol A-Glicidil Metacrilato/química , Metacrilatos/química , Valores de Referência , Solubilidade , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo , Teste de Materiais , Cânfora/análogos & derivados , Cânfora/química , Água/química , Microscopia Eletrônica de Varredura , Catequina/toxicidade , Catequina/química , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Reprodutibilidade dos Testes , Análise de Variância , Adesivos Dentinários/toxicidade , Bis-Fenol A-Glicidil Metacrilato/toxicidade , Força Compressiva , Dentina/efeitos dos fármacos , Dentina/química , Módulo de Elasticidade , Polimerização , Fibroblastos/efeitos dos fármacos , Resistência à Flexão , Metacrilatos/toxicidade
9.
Braz. oral res. (Online) ; 33: e038, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1001609

RESUMO

Abstract: This study aimed to evaluate the bond strength of a universal adhesive system to enamel surrounding real-life carious cavities. Twenty-eight permanent molars (n = 7) with carious lesions in dentin were subjected to selective carious tissue removal to firm dentin and had their crowns sectioned longitudinally. A universal adhesive system (Single Bond Universal [SBU] used in either etch-and-rinse and self-etch strategies) was compared with an etch-and-rinse Adper Single Bond 2 (ASB) and a self-etch Clearfil SE Bond (CSE) adhesive systems (control systems). Adhesives were applied on the enamel, assumed demineralized, surrounding the cavity margins and on sound enamel (control substrate). Composite cylinders were built (0.72 mm2) and microshear bond strength (µSBS) test was performed after 24 h of water storage. The µSBS values (MPa) were analyzed using two-way ANOVA and Tukey's post hoc tests (α = 0.05). Bond strength values obtained in demineralized enamel surrounding carious cavity margins were significantly lower than that obtained in sound enamel (distant from carious cavity margins) (p = 0.035). The bonding strategy of the SBU did not influenced the bond strength values, which were higher than that obtained with ASB. CSE showed similar µSBS values to ASB and SBU in the self-etch mode. In conclusion, the bond strength to enamel assumed demineralized is lower than to sound enamel. The enamel surrounding carious cavities jeopardize the bonding of universal adhesive system. The bond strength of universal adhesive is similar, regardless to bonding strategy.


Assuntos
Humanos , Colagem Dentária/métodos , Bis-Fenol A-Glicidil Metacrilato/química , Cárie Dentária/terapia , Cimentos Dentários/química , Esmalte Dentário/efeitos dos fármacos , Propriedades de Superfície , Teste de Materiais , Microscopia Eletrônica de Varredura , Distribuição Aleatória , Reprodutibilidade dos Testes , Análise de Variância , Bis-Fenol A-Glicidil Metacrilato/uso terapêutico , Estatísticas não Paramétricas , Cimentos de Resina/uso terapêutico , Cimentos de Resina/química , Cimentos Dentários/uso terapêutico , Resistência ao Cisalhamento , Dentina/efeitos dos fármacos
10.
Braz. oral res. (Online) ; 33: e083, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1019613

RESUMO

Abstract This study evaluated the influence of activation modes, on Diametral Tensile Strength (DTS) of dual cured resin cements subjected to a Mechanical Fatigue test (MF). Four dual-cured resin cements (RelyX UNICEM [U], RelyX ARC [A], ENFORCE [E] and Nexus 2 [N]) were activated by three different curing modes as follows: Self-Curing (SC), Dual Cure activation with photoactivation executed directly (DC) and Dual Cure activation with Photoactivation Through Porcelain (DCTP). After 24 hours, half of the sample was subjected to 30.000 fatigue cycles at 1 Hz frequency and 12 N load. Then, all specimens were subjected to DTS test in Instron Universal Testing Machine and data were analyzed by three-way ANOVA and Tukey's Test (5%). The results of DTS test means (MPa) and standard deviation, for each cement factor activated by SC, DC and DCTP was respectively: U (28.12 ± 5.29; 37.44 ± 6.49 and 40.10 ± 4.39), A (49.68 ± 8.42; 55.12 ± 5.16 and 63.43 ± 6.92), E (49.12 ± 3.89; 56.42 ± 8.88 and 56.96 ± 6.45) and N (61.89 ± 11.21; 59.26 ± 9.47 and 62.56 ± 10.93). Turkey's test indicated that DC is related to the highest DTS values; Nexus 2 DTS remained the same independently of activation mode and that the Porcelain disk interposition enhanced DTS only for RelyX ARC the ANOVA statistical test indicated that MF didn't alter the DTS values for all experimental groups. MF results clinical implication is that all cements tested exhibited, in an immediate loading, good cross linked bonds quality.


Assuntos
Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Cerâmica/química , Bis-Fenol A-Glicidil Metacrilato/química , Cimentos de Resina/química , Valores de Referência , Resistência à Tração , Teste de Materiais , Reprodutibilidade dos Testes , Análise de Variância , Autocura de Resinas Dentárias/métodos , Cura Luminosa de Adesivos Dentários/métodos
11.
J Mech Behav Biomed Mater ; 87: 143-147, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30071484

RESUMO

Although widely used, metallic implants have certain drawbacks in reconstructive bone surgery. Their high stiffness in respect to cortical bone can lead to complications which include periprosthetic fractures and aseptic loosening. In contrast to metallic alloys, fiber-reinforced composites (FRC) composed of a thermoset polymer matrix reinforced with continuous E-glass fibers have elastic properties matching those of bone. We investigated the mechanical properties of straight FRC tubes and FRC bone models representing the diaphysis of rabbit femur prepared from glass fiber/bisphenol A glycidyl methacrylate (BisGMA) - triethylene glycol dimethacrylate (TEGDMA) composite in three-point bending and torsion. Three groups of straight FRC tubes with different fiber orientations were mechanically tested to determine the best design for the FRC bone model. Tube 1 consisted most axially oriented unidirectional fiber roving and fewest bidirectional fiber sleevings. Fiber composition of tube 3 was the opposite. Tube 2 had moderate composition of both fiber types. Tube 2 resisted highest stresses in the mechanical tests and its fiber composition was selected for the FRC bone model. FRC bone model specimens were then prepared and the mechanical properties were compared with those of cadaver rabbit femora. In three-point bending, FRC bone models resisted 39-54% higher maximum load than rabbit femora with similar flexural stiffness. In torsion, FRC bone models resisted 31% higher maximum torque (p < 0.001) and were 38% more rigid (p = 0.001) than rabbit femora. Glass fiber-reinforced composites have good biocompatibility and from a biomechanical perspective, they could be used even in reconstruction of segmental diaphyseal defects. Development of an implant applicable for clinical use requires further studies.


Assuntos
Fêmur , Resistência à Flexão , Vidro/química , Teste de Materiais , Animais , Fenômenos Biomecânicos , Bis-Fenol A-Glicidil Metacrilato/química , Diáfises , Elasticidade , Próteses e Implantes , Coelhos
12.
Int Endod J ; 51(11): 1301-1312, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29729026

RESUMO

AIM: To evaluate the bond strength and adhesive interface between several resin cements and root dentine immediately and 6 months after radiotherapy. METHODOLOGY: Sixty maxillary canines were selected and randomly assigned to two groups (n = 30): one group was not irradiated and the other one was subjected to a cumulative radiation dose of 60 Gy. The teeth were sectioned to obtain roots 16 mm long and the canals were prepared with the Reciproc system (R50) and filled using a lateral condensation technique with an epoxy resin sealer. Each group was divided into three subgroups (n = 10) according to the resin cement used for fibreglass fibre post cementation: RelyX-U200, Panavia-F2.0 and RelyX ARC. The posts were cemented in accordance with the manufacturer's recommendations. Three 1-mm-thick dentine slices were then obtained from each root third. The first two slices in the crown-apex direction of each third were selected for the push-out test. The failure mode after debonding was determined with a stereo microscope. The third slice from each root third was selected for scanning electron microscopy (SEM) analyses to examine the resin cement-dentine interface with 100, 1000, 2000 and 4000× magnification. Bond strength data were analysed by anova and Tukey's test (α = 0.05). RESULTS: Significantly lower bond strength (P < 0.0001) was obtained after irradiation compared to nonirradiated teeth. RelyX-U200 cemented fibre posts had the higher bond strength (15.17 ± 5.89) compared with RelyX ARC (P < 0.001) and Panavia-F2.0 (P < 0.001). The evaluation after 6 months revealed lower bond strength values compared to the immediate values (P < 0.001) for irradiated and nonirradiated teeth. Cohesive failures occurred in the irradiated dentine. SEM revealed fractures, microfractures and fewer collagen fibres in irradiated root dentine. RelyX-U200 and Panavia-F2.0 were associated with a juxtaposed interface of the cement with the radicular dentine in irradiated and nonirradiated teeth, and for RelyX ARC, hybrid layer formation and tags were observed in both irradiated and nonirradiated teeth. CONCLUSION: Radiation was associated with a decrease in the push-out bond strength and with lower resin cement/root dentine interface adaptation. Self-adhesive resin cement was a better alternative for fibre post cementation in teeth subjected to radiation therapy. The bond strength decreased after 6 months.


Assuntos
Colagem Dentária , Dentina/efeitos dos fármacos , Radioterapia/métodos , Cimentos de Resina/química , Cimentos de Resina/efeitos da radiação , Raiz Dentária/efeitos dos fármacos , Bis-Fenol A-Glicidil Metacrilato/química , Bis-Fenol A-Glicidil Metacrilato/efeitos da radiação , Cimentação/métodos , Cimentos Dentários/química , Cimentos Dentários/efeitos da radiação , Materiais Dentários/química , Materiais Dentários/efeitos da radiação , Análise do Estresse Dentário , Resinas Epóxi/química , Resinas Epóxi/efeitos da radiação , Vidro , Cimentos de Ionômeros de Vidro/química , Cimentos de Ionômeros de Vidro/efeitos da radiação , Humanos , Teste de Materiais , Polietilenoglicóis/química , Polietilenoglicóis/efeitos da radiação , Ácidos Polimetacrílicos/química , Ácidos Polimetacrílicos/efeitos da radiação , Técnica para Retentor Intrarradicular , Materiais Restauradores do Canal Radicular/química , Materiais Restauradores do Canal Radicular/efeitos da radiação , Resistência ao Cisalhamento , Estresse Mecânico , Propriedades de Superfície
13.
Int J Biol Macromol ; 110: 215-226, 2018 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-29169947

RESUMO

O-Carboxymethyl chitosan (OCMC) Schiff's base was utilized for a new class of organic-inorganic hybrid material by grafting it on nano-silica-silane and further metallated with Cu (II). Here (3-Aminopropyl) triethoxysilane (APTES) was used as a linker and 2-hydroxy-1-naphthaldehyde (HN) for Schiff's base formation. The hybrid was characterized by FTIR, TGA, powder XRD, SEM, CHN, DLS, ICP-AES, diffuse reflectance UV-vis and EDX spectroscopic techniques. Magnetization measurements were carried out by VSM at room temperature. This study explored the possible synergic effect of unique properties of carboxymethyl chitosan, Schiff's base Cu (II) complex and nano-silica towards antibacterial activity and in dye degradation studies. The antibacterial performance of nano-hybrid material was examined against both Gram-positive (Escherichia coli) and Gram-negative (Bacillus subtilis) bacteria. The catalytic activity of the hybrid was tested for degradation of reactive black 5 (RB5) through advanced oxidation processes using H2O2 as oxidant. The results show a high dye degradation efficiency of 93% in 130min by the hybrid catalyst with reusability. As per published reports, Chitosan-Schiff's bases show strong antimicrobial activity and their Cu complexes exhibit good catalytic and anticancer activities. Therefore, it is expected that the new organic-inorganic hybrid would be highly applicable in environmental as well as biomedical fields.


Assuntos
Antibacterianos , Bacillus subtilis/crescimento & desenvolvimento , Bis-Fenol A-Glicidil Metacrilato , Cobre , Medicamentos de Ervas Chinesas , Escherichia coli/crescimento & desenvolvimento , Nanopartículas/química , Dióxido de Silício , Antibacterianos/química , Antibacterianos/farmacologia , Bis-Fenol A-Glicidil Metacrilato/química , Bis-Fenol A-Glicidil Metacrilato/farmacologia , Cobre/química , Cobre/farmacologia , Medicamentos de Ervas Chinesas/química , Medicamentos de Ervas Chinesas/farmacologia , Bases de Schiff/química , Bases de Schiff/farmacologia , Dióxido de Silício/química , Dióxido de Silício/farmacologia
14.
Braz. oral res. (Online) ; 32: e104, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-974458

RESUMO

Abstract This study evaluated the three-year lifespan of the bond to dentin of experimental self-etch adhesives containing benzodioxole derivatives - 1,3-benzodioxole (BDO) and piperonyl alcohol (PA) - as co-initiator alternative to amines. Adhesive resins were formulated using Bis-GMA, TEGDMA, HEMA, camphorquinone and different co-initiators: BDO, PA or ethyl 4-dimethylamino benzoate (EDAB - amine). An experimental self-etch primer was used to complete the two-step, self-etch adhesive system. Clearfil SE Bond (CSE) was used as commercial reference. Bond strength to human dentin was assessed by microtensile bond strength (µTBS) test, and failure mode was classified. Morphology of the dentin bonding interface was assessed via scanning electron microscopy (SEM). Irrespective of the dental adhesives evaluated, µTBS was higher after 24 hours compared with that after 1.5 and 3 years (p ≤ 0.001). However, adhesives with BDO and PA as co-initiators showed significantly higher bond strength than the bonding resin with EDAB (p ≤ 0.002), independent of the time evaluated. The commercial adhesive CSE showed similar bond strength compared with the other groups (p ≥ 0.05). Mixed failures were mainly observed after 24 hours, while adhesive failures were more frequently observed after 1.5 and 3 years. No notable differences in homogeneity and continuity along the bonded interfaces were detected among the materials in the SEM analysis. In conclusion, benzodioxole derivatives are feasible alternative co-initiators to tertiary amine in camphorquinone-based self-etching dental adhesive formulations.


Assuntos
Humanos , Álcoois Benzílicos/química , Adesivos Dentinários/química , Cimentos de Resina/química , Dentina/efeitos dos fármacos , Dioxóis/química , Benzodioxóis/química , para-Aminobenzoatos/química , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo , Teste de Materiais , Cânfora/análogos & derivados , Cânfora/química , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Colagem Dentária/métodos , Bis-Fenol A-Glicidil Metacrilato/química , Dentina/química , Metacrilatos/química
15.
J. appl. oral sci ; 26: e20170562, 2018. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-954492

RESUMO

Abstract The objective of this study was to compare selective physical-mechanical properties, antibacterial effects and cytotoxicity of seven temporary restorative materials (TRM): five resin-based materials [Bioplic (B), Fill Magic Tempo (FM), Fermit inlay (F), Luxatemp LC (L) and Revotek LC (R)], and zinc oxide-eugenol cement (IRM) and glass ionomer cement (GIC) as the controls. Material and methods The physical-mechanical properties were evaluated by determining microleakage (ML), ultimate tensile strength (UTS) and Shore D hardness (SDH). In addition, the polymerization rate (Pr-1), depth of cure (DC), water sorption and solubility (WS/SL) were evaluated. The antimicrobial effects of the materials were assessed by biofilm accumulation of Streptococcus mutans (BT) and the direct contact test (DCT) by exposure to Enterococcus faecalis for 1 and 24 h, and cytotoxicity by MTT assay. The data were analyzed by ANOVA or Kruskall-Wallis tests, and a complementary post-hoc method (p<0.05). Results Group B, followed by FM and GIC had significantly lower percentages of microleakage in comparison with the other groups; Groups FM and L showed the highest WS, while Groups R and FM showed the significantly lowest SL values (p<0.05). Group R showed the statistically highest UTS mean and the lowest DC mean among all groups. Group F showed the lowest S. mutans biofilm accumulation (p=0.023). Only the Group L showed continued effect against E. faecalis after 1 h and 24 h in DCT. The L showed statistically lower viability cell when compared to the other groups. Conclusions These findings suggest the antibacterial effect of the temporary materials Fill Magic and Bioplic against S. mutans, while Luxatemp showed in vitro inhibition of S. mutans biofilm accumulation and E. faecalis growth. Regarding the cell viability test, Luxatemp was the most cytotoxic and Fill Magic was shown to be the least cytotoxic.


Assuntos
Animais , Bovinos , Camundongos , Streptococcus mutans/efeitos dos fármacos , Enterococcus faecalis/efeitos dos fármacos , Resinas Compostas/farmacologia , Resinas Compostas/química , Fibroblastos/efeitos dos fármacos , Antibacterianos/sangue , Antibacterianos/farmacologia , Ácidos Polimetacrílicos/farmacologia , Ácidos Polimetacrílicos/química , Materiais Restauradores do Canal Radicular/farmacologia , Materiais Restauradores do Canal Radicular/química , Solubilidade , Resistência à Tração , Fatores de Tempo , Cimento de Óxido de Zinco e Eugenol/farmacologia , Cimento de Óxido de Zinco e Eugenol/química , Teste de Materiais , Sobrevivência Celular/efeitos dos fármacos , Reprodutibilidade dos Testes , Bis-Fenol A-Glicidil Metacrilato/farmacologia , Bis-Fenol A-Glicidil Metacrilato/química , Restauração Dentária Temporária/métodos , Cimentos de Ionômeros de Vidro/farmacologia , Cimentos de Ionômeros de Vidro/química , Testes de Dureza , Metilmetacrilatos/farmacologia , Metilmetacrilatos/química
16.
J. appl. oral sci ; 26: e20160662, 2018. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-893738

RESUMO

ABSTRACT Objective: The main goal of this study was to compare the polymerization degree of bulk-fill giomer resin cured with three different light-curing units (LCUs): a polywave third-generation (Valo); a monowave (DemiUltra: DU); and a second-generation LED (Optima 10: Opt) LCUs by using structural and mechanical properties. Material and methods: Giomer samples of 2 and 4 mm cured with three LCUs were employed in vitro analysis. The degree of curing (DC%) was determined with Fourier-Transform Infrared Spectroscopy (FTIR). Microstructural features were observed with scanning electron microscopy (SEM). Flexural strength (FS), compression strength (CS), elastic modulus and fracturing strain were determined for mechanical properties. Surface microhardness (SMH) values were also measured. Oneway ANOVA, two-way analysis of variance and Tukey multiple comparison tests were used for statistically analyzing the FS and SMH. Results: DC% values were 58.2, 47.6, and 39.7 for the 2 mm samples cured with DU, Opt., and Valo LCUs, respectively. DC% values of the 4 mm samples were 50.4, 44.6, and 38.2 for DU, Opt, and Valo, respectively. SMH values were Valo, Opt<DU at top of the samples; Valo<DU, Opt at 2 mm, and DU, Valo<Opt at 4 mm depth. Giomer samples cured with Opt and DU exhibited higher FS values than Valo. CS values were similar but compressive modulus and fracturing strain (%) varied depending on the curing protocol. Conclusions: Based on the results, it can be concluded that curing device and protocol strongly affect crosslinking reactions and thus DC%, SMH, compressive modulus and strain at break values. Consequently, it can be deduced that curing protocol is possibly the most important parameter for microstructure formation of highly-filled composite restoratives because it may bring some structural defects and physical frailties on restorations due to lower degree of polymerization.


Assuntos
Bis-Fenol A-Glicidil Metacrilato/efeitos da radiação , Bis-Fenol A-Glicidil Metacrilato/química , Resinas Compostas/efeitos da radiação , Resinas Compostas/química , Cura Luminosa de Adesivos Dentários/métodos , Polimerização/efeitos da radiação , Valores de Referência , Propriedades de Superfície/efeitos da radiação , Fatores de Tempo , Teste de Materiais , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Análise de Variância , Espectroscopia de Infravermelho com Transformada de Fourier , Estatísticas não Paramétricas , Força Compressiva , Módulo de Elasticidade , Testes de Dureza
17.
J. appl. oral sci ; 26: e20170270, 2018. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-893712

RESUMO

Abstract Although resin composites are widely used in the clinical practice, the development of recurrent caries at composite-tooth interface still remains as one of the principal shortcomings to be overcome in this field. Objectives To evaluate the activity against S. mutans biofilm of model resin composites incorporating different concentrations of ZnO-nanoparticles (ZnO-NP) and characterize their physicochemical properties. Materials and Methods Different concentrations of ZnO-NP (wt.%): E1=0, E2=0.5, E3=1, E4=2, E5=5 and E6=10 were incorporated into a model resin composite consisting of Bis-GMA-TEGDMA and barium borosilicate particles. The activity against S. mutans biofilm was evaluated by metabolic activity and lactic acid production. The following physicochemical properties were characterized: degree of conversion (DC%), flexural strength (FS), elastic modulus (EM), hardness (KHN), water sorption (Wsp), water solubility (Wsl) and translucency (TP). Results E3, E4, E5 and E6 decreased the biofilm metabolic activity and E5 and E6 decreased the lactic acid production (p<0.05). E6 presented the lowest DC% (p<0.05). No significant difference in FS and EM was found for all resin composites (p>0.05). E5 and E6 presented the lowest values of KHN (p<0.05). E6 presented a higher Wsp than E1 (p<0.05) and the highest Wsl (p<0.05). The translucency significantly decreased as the ZnO- NP concentration increased (p<0.05). Conclusions The incorporation of 2 - 5 wt.% of ZnO-NP could endow antibacterial activity to resin composites, without jeopardizing their physicochemical properties.


Assuntos
Streptococcus mutans/efeitos dos fármacos , Óxido de Zinco/farmacologia , Óxido de Zinco/química , Resinas Compostas/farmacologia , Resinas Compostas/química , Nanopartículas/química , Polietilenoglicóis/farmacologia , Polietilenoglicóis/química , Ácidos Polimetacrílicos/farmacologia , Ácidos Polimetacrílicos/química , Valores de Referência , Solubilidade , Streptococcus mutans/crescimento & desenvolvimento , Propriedades de Superfície , Teste de Materiais , Água/química , Microscopia Eletrônica de Varredura , Modelos Lineares , Reprodutibilidade dos Testes , Análise de Variância , Bis-Fenol A-Glicidil Metacrilato/farmacologia , Bis-Fenol A-Glicidil Metacrilato/química , Silicatos/farmacologia , Silicatos/química , Compostos de Bário/farmacologia , Compostos de Bário/química , Maleabilidade , Biofilmes/crescimento & desenvolvimento , Biofilmes/efeitos dos fármacos , Módulo de Elasticidade , Testes de Dureza
18.
J. appl. oral sci ; 26: e20170053, 2018. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-893684

RESUMO

ABSTRACT Objective: To evaluate the effect of erosive challenges on the tooth- restoration interface of deciduous teeth treated with different adhesive protocols. Material and Methods: Deciduous molars were cut mesiodistally, then embedded, abraded and polished (n=80). Samples were randomly divided according to the adhesive system used into: G1 (Adper Single Bond2®, etch-and-rinse), G2 (Universal Single Bond®, self-etching), G3 (OptibondFL®, etch-and-rinse with Fluoride) and G4 (BondForce®, self-etching with Fluoride). After standardized cavity preparation (2 mm diameter x 2 mm depth), adhesive systems were applied and samples were restored (composite resin Z350®). Half of the samples were exposed to erosive/abrasive cycles (n = 10, each adhesive group), and the other half (control group; n = 10) remained immersed in artificial saliva. For microleakage analysis, samples were submersed in methylene blue and analyzed at 40x magnifications. Cross-sectional microhardness (CSMH) was carried out (50 g/5 s) at 25 μm, 50 μm, and 100 μm from the eroded surface and at 25 μm, 75 μm, and 125 μm from the enamel bond interface. Results: Regarding microleakage, 7.5% of the samples showed no dye infiltration, 30% showed dye infiltration only at the enamel interface, and 62.5% showed dye infiltration through the dentin-enamel junction, with no difference between groups (p≥0.05). No significant difference was observed in CSMH at different depths (two-way ANOVA, p≥0.05). Conclusions: We did not observe significant changes in microleakage or CSMH after erosive/abrasive challenges in deciduous teeth treated with different adhesive protocols (etch-and-rinse and self-etching adhesives, with and without fluoride).


Assuntos
Humanos , Dente Decíduo/química , Erosão Dentária/etiologia , Bis-Fenol A-Glicidil Metacrilato/química , Resinas Compostas/química , Cimentos de Resina/química , Cimentos Dentários/química , Valores de Referência , Saliva Artificial/química , Propriedades de Superfície , Dente Decíduo/efeitos dos fármacos , Teste de Materiais , Distribuição Aleatória , Reprodutibilidade dos Testes , Análise de Variância , Estatísticas não Paramétricas , Esmalte Dentário/efeitos dos fármacos , Esmalte Dentário/química , Infiltração Dentária/etiologia , Dentina/efeitos dos fármacos , Dentina/química , Fluoretos/química , Testes de Dureza
19.
J. appl. oral sci ; 25(5): 523-532, Sept.-Oct. 2017. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-893652

RESUMO

Abstract Objectives: This study investigated whether increasing the concentration of acidic monomers in one-step adhesives would allow reducing their application time without interfering with the bonding ability to primary enamel and dentin. Material and methods: Experimental one-step self-etch adhesives were formulated with 5 wt% (AD5), 20 wt% (AD20), or 35 wt% (AD35) acidic monomer. The adhesives were applied using rubbing motion for 5, 10, or 20 s. Bond strengths to primary enamel and dentin were tested under shear stress. A commercial etch-and-rinse adhesive (Single Bond 2; 3M ESPE) served as reference. Scanning electron microscopy was used to observe the morphology of bonded interfaces. Data were analysed at p<0.05. Results: In enamel, AD35 had higher bond strength when rubbed for at least 10 s, while application for 5 s generated lower bond strength. In dentin, increased acidic monomer improved bonding only for 20 s rubbing time. The etch-and-rinse adhesive yielded higher bond strength to enamel and similar bonding to dentin as compared with the self-etch adhesives. The adhesive layer was thicker and more irregular for the etch-and-rinse material, with no appreciable differences among the self-etch systems. Conclusion: Overall, increasing the acidic monomer concentration only led to an increase in bond strength to enamel when the rubbing time was at least 10 s. In dentin, despite the increase in bond strength with longer rubbing times, the results favoured the experimental adhesives compared to the conventional adhesive. Reduced rubbing time of self-etch adhesives should be avoided in the clinical setup.


Assuntos
Humanos , Colagem Dentária/métodos , Adesivos Dentinários/química , Bis-Fenol A-Glicidil Metacrilato/química , Esmalte Dentário/efeitos dos fármacos , Dentina/efeitos dos fármacos , Metacrilatos/química , Solventes/química , Propriedades de Superfície/efeitos dos fármacos , Fatores de Tempo , Teste de Materiais , Água/química , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Análise de Variância , Falha de Restauração Dentária , Resistência ao Cisalhamento , Glicerol/química
20.
J. appl. oral sci ; 25(4): 412-419, July-Aug. 2017. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-893634

RESUMO

Abstract Objective This study evaluated the effect of grape seed extract (GSE) incorporation on the mechanical properties, water sorption, solubility, and GSE release from the experimental adhesive resins. Material and Methods An experimental comonomer mixture, consisting of 40% Bis-GMA, 30% Bis MP, 28% HEMA, 0.26% camphorquinone and 1% EDMAB, was used to prepare four GSE-incorporated adhesive resins at concentrations of 0.5, 1, 1.5, and 2 wt%. The neat resin without GSE was used as the control. Six resin beams (25 mm x 2 mm x 2 mm) per group were prepared for flexural strength and modulus of elasticity evaluations using a universal testing machine at a crosshead speed of 1 mm/min. Five disks (6 mm in diameter and 2 mm in thickness) per group were used for microhardness measurements using a Leitz micro-hardness tester with Leica Qgo software. Five disks (7 mm in diameter and 2 mm in thickness) per group were prepared and stored in deionized water for 28 days. Water sorption, solubility, and GSE release in deionized water were calculated for each GSE-incorporated adhesive at the end of 28th day. Data was evaluated using one-way ANOVA and Tukey multiple comparisons. Results Flexural strength, modulus of elasticity and microhardness of GSE-incorporated adhesive decreased significantly with incorporation of 1.5% of GSE (p<0.05). Addition of GSE had no effect on the water sorption of the adhesive resins (p=0.33). The solubility of the resin also increased significantly with incorporation of 1.5% of GSE (p<0.05). Quantities of GSE release increased with increased concentration of GSE in the adhesive resin. Conclusion Up to 1% of GSE can be incorporated into a dental adhesive resin without interfering with the mechanical properties or solubility of the resins.


Assuntos
Cânfora/análogos & derivados , Bis-Fenol A-Glicidil Metacrilato/química , Cimentos de Resina/química , Extrato de Sementes de Uva/química , para-Aminobenzoatos/química , Metacrilatos/química , Valores de Referência , Solubilidade , Fatores de Tempo , Teste de Materiais , Cânfora/química , Água/química , Reprodutibilidade dos Testes , Análise de Variância , Estatísticas não Paramétricas , Maleabilidade , Proantocianidinas/química , Módulo de Elasticidade , Testes de Dureza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA