Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 221: 115003, 2022 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-36095885

RESUMO

The probable carcinogenic nitrosamine impurities, such as N-nitrosodiethylamine (NDEA) and N-nitrosodimethylamine (NDMA), have been detected from various pharmaceuticals in recent years. The sensitive chromatographic methods, including liquid chromatography (LC) and gas chromatography (GC), have been applied for analyzing nitrosamines in the pharmaceutical substrates, such as sartans, ranitidine and metformin. In comparison of LC, the efficacy of GC for analyzing multiple nitrosamines in diverse pharmaceuticals will be limited or attenuated owing to the chemical properties of target analytes or matrix hinderance of pharmaceutical substrates. To extend the applicability of GC analysis for multiple nitrosamines in pharmaceuticals, this study presented a gas chromatograph tandem mass (GC-MS/MS) method for monitoring 14 nitrosamines within 44 pharmaceuticals, whereas the headspace-solid phase microextraction (HS-SPME) sampling mode was introduced. Chromatographic separation was achieved on a DB-heavyWax column (30 m × 0.25 mm; i.d., 0.25 µm), whereas the HS-SPME sampling mode with a 50/30 µm DVB/CAR/PDMS extracting fiber was applied for comparison of the direct injection mode. Meanwhile, the HS-SPME conditions were optimized to evaluate the effects of the parameters on analyzing total nitrosamines in pharmaceuticals by GC-MS/MS. The optimal conditions of HS-SPME were as follows: extracting solution of 90% NaCl, HS incubation time 1 min, SPME adsorbing at 80 â„ƒ for 30 min, and desorbing at 250 â„ƒ for 5 min. The limit of quantification (LOQ) for 14 nitrosamines in pharmaceutical matrices under the optimal conditions was 0.05 µg/g for the optimal HS-SPME, whereas the value was 0.05-0.25 µg/g for direct injection.


Assuntos
Metformina , Nitrosaminas , Bloqueadores do Receptor Tipo 1 de Angiotensina II/análise , Dietilnitrosamina/análise , Dimetilnitrosamina/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Metformina/análise , Nitrosaminas/análise , Preparações Farmacêuticas , Ranitidina , Cloreto de Sódio , Microextração em Fase Sólida/métodos , Espectrometria de Massas em Tandem
2.
Cardiovasc Drugs Ther ; 34(4): 579-584, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32318933

RESUMO

PURPOSE: Beginning in July of 2018, the FDA issued a voluntary recall regarding the presence of a contaminant found in the manufacturing of valsartan. What would ensue has become a largely unprecedented sequence of alarming events since the FDA began reporting public recalls, withdrawals and safety alerts on their website in 2016. Since then, the United States has been significantly impacted by drug recalls affecting angiotensin receptor blockers. This report arms clinicians with additional guidance and provides a framework for responding appropriately to future similar incidents and includes an overview of the angiotensin receptor blockers, and their effects and safety profiles. METHODS: This report includes a review of data from all pertinent clinical and scientific sources including information from the FDA's inspection documents and recall website. Additional information is provided on the specific bottles including all lot numbers, expiration dates, etc. RESULTS: The recalls/withdrawals are attributable to the presence of cancer-causing contaminants identified during the manufacturing process from drug manufacturers abroad. The root causes behind the recalls and subsequent shortage appear multifactorial, and stem to a certain extent from the outsourcing of medication manufacturing overseas and lack of quality checks and appropriate oversight. CONCLUSIONS: This inherent issue is not likely to resolve soon and has eroded the public trust of/in the healthcare system and the pharmaceutical industry. Patients and healthcare providers are significantly affected and should have a full understanding of the matter in order to guide appropriate response and actions.


Assuntos
Bloqueadores do Receptor Tipo 1 de Angiotensina II/análise , Carcinógenos/análise , Aprovação de Drogas , Contaminação de Medicamentos , Indústria Farmacêutica/normas , Recall de Medicamento , Controle de Qualidade , United States Food and Drug Administration/normas , Bloqueadores do Receptor Tipo 1 de Angiotensina II/efeitos adversos , Humanos , Segurança do Paciente , Medição de Risco , Fatores de Risco , Estados Unidos
3.
AAPS PharmSciTech ; 20(5): 166, 2019 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-30989447

RESUMO

The presence of N-nitrosodimethylamine (NDMA) and N-nitrosodiethylamine (NDEA) impurities in angiotensin II receptor blocker (ARB) drugs containing tetrazole ring has triggered worldwide product recalls. The purpose of this article is to identify the potential gap area in current pharmaceutical industry practice that might have led to the NMDA and NDEA impurities escaping the drug manufacturer's and FDA's attention. The impact of process change was not adequately assessed by the manufacturer of contaminated APIs (active pharmaceutical ingredients), and potential for generation of mutagenic or other toxic impurities was not considered. The safety and risk associated with a chemical synthetic process was also not evaluated. This is primarily due to current industry practice which focuses on controlling the impurities above reporting threshold. ICH Q3A and FDA guidance on genotoxic and carcinogenic impurities in drug substances and products need to be integrated so that the ICH Q3A decision tree (attachment 3) begins by checking whether the synthetic process has been evaluated for the potential to generate toxic impurities. The compliance with ICH Q3A limits should be carried out only after the process has been determined to be safe without the risk of generating mutagenic and carcinogenic impurities.


Assuntos
Contaminação de Medicamentos , Recall de Medicamento , Valsartana/química , Bloqueadores do Receptor Tipo 1 de Angiotensina II/análise , Bloqueadores do Receptor Tipo 1 de Angiotensina II/toxicidade , Dietilnitrosamina/análise , Dimetilnitrosamina/análise , Composição de Medicamentos , Indústria Farmacêutica , Humanos , Mutagênicos/análise , Mutagênicos/toxicidade , Segurança do Paciente , Estados Unidos , United States Food and Drug Administration
4.
Pharmazie ; 70(6): 368-73, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26189296

RESUMO

A capillary zone electrophoresis method was developed for the simultaneous determination of valsartan (VAL), amlodipine besylate (AML) and hydrochlorothiazide (HCZ) in their combined tablets. Separation was achieved on a fused silica capillary by applying a potential of 15 kV (positive polarity) and a running background electrolyte containing 40 mM phosphate buffer at pH 7.5 with UV detection at 230 nm. The samples were injected hydrodynamically for 3s at 0.5 psi and the temperature of the capillary cartridge was kept at 25 degrees C. Pyrazinoic acid was used as an internal standard. The method was validated according to ICH guidelines regarding specificity, linearity, limits of detection and quantitation, accuracy and precision, (Supplementary materials, Table S2). The method showed satisfactory linearity in the ranges of 10-200, 2-20 and 2-20 µg mL(-1) with LODs of 1.82, 0.39, 0.65 µg mL(-1) and LOQs of 5.51, 1.17, 1.96 µg mL(-1) for VAL, AML and HCZ, respectively. The proposed method was successfully applied for the analysis of the studied drugs in their laboratory prepared mixtures and co-formulated tablets. The results were compared with reported methods and no significant differences were found. The proposed method can be used for quality control of the cited drugs in ordinary laboratories.


Assuntos
Anlodipino/análise , Bloqueadores do Receptor Tipo 1 de Angiotensina II/análise , Anti-Hipertensivos/análise , Bloqueadores dos Canais de Cálcio/análise , Diuréticos/análise , Hidroclorotiazida/análise , Tetrazóis/análise , Valina/análogos & derivados , Calibragem , Combinação de Medicamentos , Eletroforese Capilar , Limite de Detecção , Padrões de Referência , Reprodutibilidade dos Testes , Comprimidos/análise , Valina/análise , Valsartana
5.
Mol Pharm ; 8(5): 1789-98, 2011 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-21812443

RESUMO

Telmisartan, a selective angiotensin II receptor antagonist, is primarily excreted via hepatobiliary transport. The predominant contribution of organic anion transporting polypeptide (OATP) 1B3 in its hepatic uptake of telmisartan has been demonstrated by in vitro transport studies. In the present study, a quantitative positron emission tomography (PET) methodology was developed for in vivo kinetic assessment of hepatobiliary transport of telmisartan. Serial abdominal PET scans were performed in rats following intravenous administration of [(11)C]telmisartan as a radiotracer. PET scans revealed that [(11)C]telmisartan was localized primarily in the liver and some of the radioactivity moved to the intestine, which corresponds to biliary excretion. Radiometabolite analysis by radiometric HPLC showed that [(11)C]telmisartan was converted to its acylglucuronide, which was mainly detected in bile, but little in plasma and liver. Integration plot analysis revealed that [(11)C]telmisartan was taken up into the liver as rapidly as the hepatic blood flow rate, and the radiometabolite was subsequently excreted into the bile. When rifampicin, a typical Oatp inhibitor, was coadministered with [(11)C]telmisartan in rats, hepatic uptake clearance of [(11)C]telmisartan was significantly decreased, whereas biliary efflux clearance was not changed. Coinjection with unlabeled telmisartan (4 and 10 mg/kg) also decreased hepatic uptake clearance of [(11)C]telmisartan. On the other hand, PET imaging analysis revealed a significant increase of biliary efflux when telmisartan dose was increased to more than 4 mg/kg. These results suggested that the hepatic uptake of [(11)C]telmisartan mainly consists of a saturable process mediated by Oatps in rats, according to noninvasive real-time measurement of tissue radioactivity with the use of PET. The present study with rats is expected to provide the feasibility of PET imaging study to quantitatively estimate OATP1B3 function in humans.


Assuntos
Bloqueadores do Receptor Tipo 1 de Angiotensina II/farmacocinética , Anti-Hipertensivos/farmacocinética , Benzimidazóis/farmacocinética , Benzoatos/farmacocinética , Fígado/diagnóstico por imagem , Fígado/metabolismo , Transportadores de Ânions Orgânicos Sódio-Independentes/metabolismo , Bloqueadores do Receptor Tipo 1 de Angiotensina II/administração & dosagem , Bloqueadores do Receptor Tipo 1 de Angiotensina II/análise , Bloqueadores do Receptor Tipo 1 de Angiotensina II/sangue , Animais , Anti-Hipertensivos/administração & dosagem , Anti-Hipertensivos/análise , Anti-Hipertensivos/sangue , Benzimidazóis/administração & dosagem , Benzimidazóis/análise , Benzimidazóis/sangue , Benzoatos/administração & dosagem , Benzoatos/análise , Benzoatos/sangue , Bile/química , Transporte Biológico/efeitos dos fármacos , Biotransformação/efeitos dos fármacos , Radioisótopos de Carbono , Relação Dose-Resposta a Droga , Inibidores Enzimáticos/farmacologia , Estudos de Viabilidade , Fígado/irrigação sanguínea , Fígado/efeitos dos fármacos , Circulação Hepática , Masculino , Taxa de Depuração Metabólica/efeitos dos fármacos , Transportadores de Ânions Orgânicos Sódio-Independentes/antagonistas & inibidores , Tomografia por Emissão de Pósitrons , Isoformas de Proteínas/antagonistas & inibidores , Isoformas de Proteínas/metabolismo , Ratos , Ratos Sprague-Dawley , Rifampina/farmacologia , Membro 1B3 da Família de Transportadores de Ânion Orgânico Carreador de Soluto , Telmisartan , Distribuição Tecidual/efeitos dos fármacos
6.
Drug Test Anal ; 2(10): 489-93, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20872895

RESUMO

Amlodipine, a dihydropyridine calcium channel blocker, and valsartan, an angiotensin II receptor blocker, are co-formulated in a single-dose combination for the treatment of hypertension. The combination is used by patients whose blood pressure is not adequately controlled on either component monotherapy. This work describes a simple, sensitive, and reliable spectrofluorimetric method for the simultaneous determination of the two antihypertensive drugs; amlodipine besylate (AML) and valsartan (VAL) in their combined tablets. The method involved measurement of the native fluorescence at 455 nm (λ(Ex) 360 nm) and 378 nm (λ(Ex) 245 nm) for AML and VAL, respectively. Analytical performance of the proposed spectrofluorimetric procedure was statistically validated with respect to linearity, ranges, precision, accuracy, selectivity, robustness, detection, and quantification limits. Regression analysis showed good correlation between fluorescence intensity and concentration over the concentration ranges 0.2-3.6 and 0.008-0.080 µg mL⁻¹ for AML and VAL, respectively. The limits of detection were 0.025 and 0.0012 µg mL⁻¹ for AML and VAL, respectively. The proposed method was successfully applied for the assay of the two drugs in their combined pharmaceutical tablets with recoveries not less than 98.85%. No interference was observed from common pharmaceutical additives. The results were favourably compared with those obtained by a reference spectrophotometric method.


Assuntos
Anlodipino/análise , Bloqueadores do Receptor Tipo 1 de Angiotensina II/análise , Bloqueadores dos Canais de Cálcio/análise , Espectrofotometria/métodos , Comprimidos/química , Tetrazóis/análise , Valina/análogos & derivados , Combinação de Medicamentos , Limite de Detecção , Espectrofotometria/economia , Valina/análise , Valsartana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA