Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 188
Filtrar
1.
J Natl Cancer Inst ; 116(5): 737-744, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38180898

RESUMO

BACKGROUND: Industrial facilities are not located uniformly across communities in the United States, but how the burden of exposure to carcinogenic air emissions may vary across population characteristics is unclear. We evaluated differences in carcinogenic industrial pollution among major sociodemographic groups in the United States and Puerto Rico. METHODS: We evaluated cross-sectional associations of population characteristics including race and ethnicity, educational attainment, and poverty at the census tract level with point-source industrial emissions of 21 known human carcinogens using regulatory data from the US Environmental Protection Agency. Odds ratios and 95% confidence intervals comparing the highest emissions (tertile or quintile) to the referent group (zero emissions [ie, nonexposed]) for all sociodemographic characteristics were estimated using multinomial, population density-adjusted logistic regression models. RESULTS: In 2018, approximately 7.4 million people lived in census tracts with nearly 12 million pounds of carcinogenic air releases. The odds of tracts having the greatest burden of benzene, 1,3-butadiene, ethylene oxide, formaldehyde, trichloroethylene, and nickel emissions compared with nonexposed were 10%-20% higher for African American populations, whereas White populations were up to 18% less likely to live in tracts with the highest emissions. Among Hispanic and Latino populations, odds were 16%-21% higher for benzene, 1,3-butadiene, and ethylene oxide. Populations experiencing poverty or with less than high school education were associated with up to 51% higher burden, irrespective of race and ethnicity. CONCLUSIONS: Carcinogenic industrial emissions disproportionately impact African American and Hispanic and Latino populations and people with limited education or experiencing poverty thus representing a source of pollution that may contribute to observed cancer disparities.


Assuntos
Poluentes Atmosféricos , Humanos , Estados Unidos/epidemiologia , Poluentes Atmosféricos/análise , Poluentes Atmosféricos/efeitos adversos , Estudos Transversais , Exposição Ambiental/efeitos adversos , Carcinógenos/análise , Butadienos/análise , Butadienos/efeitos adversos , Benzeno/análise , Poluição do Ar/efeitos adversos , Poluição do Ar/análise , Fatores Socioeconômicos , Fatores Sociodemográficos , Formaldeído/análise , Formaldeído/efeitos adversos , Níquel/análise , Níquel/efeitos adversos , Indústrias/estatística & dados numéricos , Porto Rico/epidemiologia
2.
Phytochem Anal ; 35(3): 579-585, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38130156

RESUMO

INTRODUCTION: The active compound (E)-1-(3',4'-dimethoxyphenyl)butadiene (DMPBD) isolated from the rhizomes of Zingiber cassumunar Roxb. has potent anti-inflammatory and anticancer activities. Although DMPBD is one of the promising drug candidates for phytomedicine, its limited stability impedes its widespread use. For the development of new drugs, the assessment of their chemical stability is essential, ensuring they maintain their properties within specified limits throughout the period from production until use. OBJECTIVE: In the present study, we aimed to evaluate the stability of DMPBD under various conditions, including different solvents, temperatures, and lighting conditions, to identify the factors affecting stability and optimize the storage and handling conditions. METHODOLOGY: DMPBD samples subjected to the different conditions tested were monitored by quantitative 1H NMR (qHNMR), using an internal standard for the determination of the absolute quantity of DMPBD as a function of time and the changes thereof within 1 month. RESULTS: Significant decomposition of DMPBD was observed in chloroform-d1, whereas its content remained constant in methanol-d4. The content of DMPBD was maintained upon storage at temperatures below 4°C, both as methanolic solution and in the crude extract. Exposure to light had a slight negative impact on its contents. Some degradation products could be identified as resulting from O2-induced cleavage of the diene moiety. CONCLUSIONS: For pharmacological/therapeutic applications, DMPBD should be stored in the form of the crude extract or as a purified material in methanolic solution. Ideally, the storage temperature should be below 4°C and O2 should be excluded.


Assuntos
Extratos Vegetais , Zingiberaceae , Extratos Vegetais/química , Butadienos/análise , Butadienos/farmacologia , Rizoma/química , Zingiberaceae/química
3.
J Chromatogr A ; 1711: 464442, 2023 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-37844445

RESUMO

Owing to the growing emphasis on child safety, it is greatly urgent to identify and assess the unknown compounds and discriminate the recycled materials for plastic toys. In this study, gas chromatography mass spectrometry coupled with static headspace has been optimized by response surface methodology for non-targeted screening of unknown volatiles in acrylonitrile-butadiene-styrene (ABS) plastic toys. Optimum conditions for static headspace were 120 °C for extraction temperature and 48 min for extraction time. A total of 83 volatiles in 11 categories were qualitatively identified by matching the NIST database library, retention index and standard materials. Considering high positive rate and potential toxicity, high-risk volatiles in ABS plastic toys were listed and traced for safety pre-warning. Moreover, the differential volatiles between virgin and recycled ABS plastics were screened out by orthogonal partial least-squares discrimination analysis. Principal component analysis, hierarchical cluster analysis and linear discrimination analysis were employed to successfully discriminate recycled ABS plastic toys based on the differential volatiles. The proposed strategy represents an effective and promising analytical method for non-targeted screening and risk assessment of unknown volatiles and discrimination of recycled materials combining with various chemometric techniques for children's plastic products to safeguard children's health.


Assuntos
Acrilonitrila , Estireno , Criança , Humanos , Butadienos/análise , Quimiometria , Plásticos/química
4.
Environ Pollut ; 334: 122198, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37453688

RESUMO

The impact of microplastics (MPs, plastic particles ≤5 mm) on ecosystems is of great concern. Road surfaces represent a significant source of MPs where plastic fragments are physically and chemically reduced to MPs. However, the literature lacks information on fragmentation tendencies below 11 µm. This study aimed to characterize the occurrence of MPs in road dust in different size fractions down to 1.1 µm. Road dust was collected at five sites near a major road in Kusatsu city, Japan, and partitioned by size into 13 fractions (1.1-850 µm). The coarser fractions accounted for a greater proportion of the dust. The percentage of organic matter, determined by loss on ignition, increased as the fractions became finer. Pyrolysis-gas chromatography-mass spectrometry was used to quantify 12 types of polymers in each fraction. The dust was found to contain nine types of MP, namely, polyethylene (PE), polypropylene (PP), polyvinylchloride (PVC), polystyrene (PS), styrene/butadiene rubber (SBR), acrylonitrile/butadiene/styrene resin (ABS), polycarbonate (PC), polymethylmethacrylate (PMMA), and polyamide 66 (PA66). The total MP concentration in road dust particles by particle size fraction (concentrationf) began to increase from the 125-250 µm fraction and remained elevated in finer fractions down to 1.1 µm, indicating that MPs in the road dust micronized to at least 1.1 µm. However, for individual polymer types, the tendency for concentrationf to increase or decrease with particle size fraction varied: the concentrationf of some polymers, such as PE and PVC, remained elevated in fractions down to 1.1 µm; the concentrationf of SBR, a rubber-MP, showed a stable or decreasing trend in fractions of 7.0-11 µm and finer. Particles of PE, PVC, and some other plastics might become increasingly finer, even down to 1.1 µm. Further research is needed to understand the comminution limits of these polymers under pertinent environmental conditions.


Assuntos
Plásticos , Poluentes Químicos da Água , Plásticos/análise , Microplásticos , Borracha , Butadienos/análise , Poeira/análise , Japão , Tamanho da Partícula , Ecossistema , Polímeros , Polietilenos/análise , Estirenos/análise , Monitoramento Ambiental/métodos , Poluentes Químicos da Água/análise
5.
Sci Rep ; 12(1): 22103, 2022 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-36543865

RESUMO

Chemicals containing Volatile Organic Compounds (VOCs) are commonly used in the machine carpet production. 1,3-butadiene and styrene are main components of the carpenter's glue used in carpet factories. Exposition to these chemicals can lead to a number of adverse health effects. This is the first study of the human health risk assessment due to inhalational exposure to 1,3-butadiene (BD) and styrene (ST) performed among workers in the carpet factories in Kashan city, Iran. The importance of the study was related with the fact of high popularity of carpet production in the South Asia countries. Inhalation exposure to BD and ST were measured based on the National Institute for Occupational Safety and Health (NIOSH) 1024 and 1501 methods, respectively. The cancerogenic risk (CR) and non-cancerogenic risk described as Hazard Quotient (HQ) values were calculated based on the United States Environmental Protection Agency (USEPA) method. The sensitivity and uncertainty analysis were performed by the Monte Carlo simulation (MCS) technique. The average concentration measured of BD and ST during work shifts of employees were 0.039 mg m-3 (0.017 ppm) and 12.108 mg m-3 (2.84 ppm), respectively. The mean ± SD value of estimated cancerogenic risk in inhalation exposure to BD and ST were equal to 5.13 × 10-3 ± 3.85 × 10-4 and 1.44 × 10-3 ± 2.36 × 10-4, respectively exceeding the acceptable risk level of 10-6 defined by USEPA. The average non-carcinogenic risk (HQ) values of BD and ST were equal to 8.50 × 100 and 5.13 × 100, respectively exceeding the acceptable risk level of 1. As the results of our studies exceeded both cancerogenic and non-carcinogenic risk values it indicates that adverse health effects due to inhalational exposure to BD and ST for workers in the machine carpet industry are very likely. To avoid negative health effects protective measures for employees in the factories should be introduced immediately and furher detailed research are recommended.


Assuntos
Exposição Ocupacional , Estireno , Estados Unidos , Humanos , Estireno/toxicidade , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/análise , Pisos e Cobertura de Pisos , Método de Monte Carlo , Butadienos/toxicidade , Butadienos/análise , Medição de Risco
6.
Sci Total Environ ; 850: 157983, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-35973540

RESUMO

Freshwater pollution is a huge concern. A study aiming to evaluate physico-chemical characteristics, microbiota, occurrence of two groups of persistent environmental pollutants with similar chemical properties (polycyclic aromatic hydrocarbons- PAHs and microplastics - MPs) in Alqueva's surface water was performed during 2021. Water samples were collected at three spots related to touristic activities (two beaches and one marina) during the Winter, Spring, Summer and Autumn seasons. In addition, the presence of biofilms on plastic and natural materials (stone, wood/ vegetal materials) were assessed and compared. Water quality based on physicochemical parameters was acceptable with a low eutrophication level. PAHs concentration levels were lower than the standard limits established for surface waters by international organizations. However, carcinogenic compounds were detected in two sampling locations, which can pose a problem for aquatic ecosystems. PAHs profiles showed significant differences when comparing the dry seasons with the rainy seasons, with a higher number of different compounds detected in Spring. Low molecular weigh compounds, usually associated with the atmospheric deposition and petroleum contamination, were more prevalent. MPs were detected in all samples except one during the Winter season. The polymers detected were poly(methyl-2-methylpropenoate), polystyrene, polyethylene terephthalate, polyamide, polypropylene, styrene butadiene, polyvinyl chloride and low /high density polyethylene with the last being the most frequent. Biofilms were more often detected on plastics than on natural materials. In addition, biofilms detected on plastics were more complex with higher microbial diversity (e.g., bacteria, fungi/yeast and phytoplancton organisms) and richer in extrapolymeric material. Based on morphological analysis a good agreement between microbiota and microorganism present in the biofilms was found. Among microbiota were identified microorganisms previously linked to plastic and PAHs detoxification suggesting the need for further studies to evaluate the viability of using biofilms as part of a green bioremediation strategy to mitigate water pollution.


Assuntos
Petróleo , Hidrocarbonetos Policíclicos Aromáticos , Poluentes Químicos da Água , Biofilmes , Butadienos/análise , Ecossistema , Monitoramento Ambiental , Microplásticos , Nylons , Petróleo/análise , Plásticos/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Polietileno/análise , Polietilenotereftalatos , Polipropilenos/análise , Poliestirenos/análise , Cloreto de Polivinila/análise , Poluentes Químicos da Água/análise
7.
ACS Appl Mater Interfaces ; 14(9): 11587-11596, 2022 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-35174700

RESUMO

Precise detection of breath isoprene can provide valuable information for monitoring the physical and physiological status of human beings or for the early diagnosis of cardiovascular diseases. However, the extremely low concentration and low chemical reactivity of breath isoprene hamper the selective and sensitive detection of isoprene using oxide semiconductor chemiresistors. Herein, we report that macroporous WO3 microspheres whose inner macropores are surrounded by Au nanoparticles exhibit a high response (resistance ratio = 11.3) to 0.1 ppm isoprene under highly humid conditions at 275 °C and an extremely low detection limit (0.2 ppb). Furthermore, the sensor showed excellent selectivity to isoprene over five interferants that could be exhaled by humans. Notably, the selectivity to isoprene is critically dependent on the location of Au nanocatalysts and macroporosity. The mechanism underlying the selective isoprene detection is investigated in relation to the reforming of less reactive isoprene into more reactive intermediate species promoted by macroporous catalytic reactors, which is confirmed by the analysis using a proton transfer reaction quadrupole mass spectrometer. The sensor for breath analysis has high potential for simple physical and physiological monitoring as well as disease diagnosis.


Assuntos
Testes Respiratórios/métodos , Butadienos/análise , Compostos de Ouro/química , Hemiterpenos/análise , Nanopartículas Metálicas/química , Óxidos/química , Tungstênio/química , Catálise , Humanos , Espectrometria de Massas/métodos , Microesferas , Sensibilidade e Especificidade , Temperatura
8.
J Mass Spectrom ; 56(4): e4588, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32633879

RESUMO

Breath volatile biomarkers are capable of distinguishing patients with various cancers. However, high throughput analytical technology is a prerequisite to a large-cohort study intended to discover reliable breath biomarkers for cancer diagnosis. Single-photon ionization (SPI) is a universal ionization technology, and SPI-mass spectrometry (SPI-MS) shows a remarkable advantage in the comprehensive detection of volatile organic compounds (VOCs), in particular, nonpolar compounds. In this study, we have introduced SPI-MS coupled with on-line thermal desorption (TD-SPI-MS) to demonstrate nontarget analysis of breath VOCs for gastric cancer patients. The breath fingerprints of the gastric cancer patients were significantly distinct from that of the control group. Acetone, isoprene, 1,3-dioxolan-2-one, phenol, meta-xylene, 1,2,3-trimethylbenzene, and phenyl acetate showed higher relative peak intensities in the breath profiles of gastric cancer patients. A diagnostic prediction model was further developed by using a training set (121 samples) and validated with a test set (53 samples). The predication accuracy of the developed model was 96.2%, and the area under the curve (AUC) of the receiver operator characteristic curve (ROC) was 0.997, indicating a satisfactory prediction ability of the developed model. Thus, by taking gastric cancer as an example, we have shown that TD-SPI-MS will be a promising tool for high throughput analysis of breath samples to discover characteristic VOCs in patients with various cancers.


Assuntos
Biomarcadores Tumorais/análise , Testes Respiratórios/métodos , Espectrometria de Massas/métodos , Neoplasias Gástricas/diagnóstico , Compostos Orgânicos Voláteis/análise , Acetatos/análise , Acetona/análise , Butadienos/análise , Estudos de Coortes , Dioxolanos/análise , Expiração , Hemiterpenos/análise , Humanos , Fenol/análise , Fenóis/análise , Curva ROC , Xilenos/análise
9.
Toxicol Ind Health ; 36(12): 960-970, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33108261

RESUMO

1,3-Butadiene is classified as carcinogenic to humans by inhalation. This study aimed to assess cancer and non-cancer risk following occupational exposure to 1,3-butadiene. This cross-sectional study was conducted in a petrochemical plant producing acrylonitrile butadiene styrene copolymer in Iran. Occupational exposure to 1,3-butadiene was measured according to the National Institute for Occupational Safety and Health 1024 method. Cancer and non-cancer risk assessment were performed according to the United States Environmental Protection Agency method. The average occupational exposure to 1,3-butadiene during work shifts among all participants was 560.82 ± 811.36 µg m-3. The average lifetime cancer risk (LCR) in the present study was 2.71 × 10-3; 82.2% of all exposed workers were within the definite carcinogenic risk level. Also, the mean non-cancer risk (hazard quotient (HQ)) among all participants was 10.82 ± 14.76. The highest LCR and HQ were observed in the safety and fire-fighting station workers with values of 7.75 × 10-3 and 36.57, respectively. The findings revealed that values of carcinogenic and noncarcinogenic risk in the majority of participants were within the definitive and unacceptable risk levels. Therefore, corrective measures are necessary to protect these workers from non-cancer and cancer risks from 1,3-butadiene exposure.


Assuntos
Butadienos/análise , Neoplasias/epidemiologia , Doenças Profissionais/epidemiologia , Exposição Ocupacional/análise , Indústria de Petróleo e Gás , Resinas Acrílicas , Estudos Transversais , Humanos , Irã (Geográfico) , Saúde Ocupacional , Poliestirenos
10.
Talanta ; 212: 120464, 2020 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-32113524

RESUMO

The use of additive-manufactured components in medical applications, specifically medical devices (e.g., orthopedic casts), has increased in recent years. Such devices may be fabricated at the point of care using consumer-grade additive manufacturing. Limited studies have been conducted to evaluate the extractable substances of these devices. Chemical characterization followed by toxicological risk assessment is one means of evaluating safety of devices. This study was designed to determine the extractables profile of additive-manufactured materials according to filament grade and post-processing method. Feedstocks for additive manufacturing were tested as filament and manufactured casts, while the cast from consumer-grade filament (CGF) was post-processed. Samples were extracted using three solvents of varying polarities. Extracts were analyzed by gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS) techniques. In GC/MS analysis, isopropanol extracts generated fewer compound identifications for USP Class VI filament (USPF)-based casts (3) compared with the respective filament (17) while hexane generated the most compound identifications for the finished cast manufactured from CGF. CGF was found to have the highest number of nonvolatile extractables for isopropanol (15) and hexane (34) by positive ion LC/MS. Additionally, CGF produced more non-polar extractables in hexane than the USPF. A known polymer byproduct and potential genotoxicant, styrene acrylonitrile (SAN) trimer, was one of the compounds identified in both GC/MS and LC/MS at quantities ranging from 19 to 270 µg g-1. Overall these results suggested that the extractables profile was affected by the filament material, printing procedure, and post-processing method.


Assuntos
Resinas Acrílicas/análise , Butadienos/análise , Equipamentos Ortopédicos , Poliestirenos/análise , Extração em Fase Sólida , Compostos Orgânicos Voláteis/análise
11.
Bull Environ Contam Toxicol ; 104(1): 1-7, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31745598

RESUMO

Hexachloro-1,3-butadiene (HCBD) is a persistent organic pollutant listed in Annex A and C of the Stockholm Convention. This review summarized the sources, occurrence, toxicity, and transformation of HCBD in the environment. HCBD had no natural sources, and anthropogenic sources made it frequently detected in environmental medium, generally at µg L- 1 and µg kg- 1 in water and soil (or organism) samples, respectively. HCBD posed reproductive, genetic, and potentially carcinogenic toxicity to organisms, threatening human health and the ecosystem. Upon biodegradation, photodegradation and physicochemical degradation processes, HCBD can be degraded to a different extent. Nevertheless, further studies should be focused on the potential emission sources and the impact of HCBD on human health and the environment. Additionally, exploring removal technologies based on advanced oxidation and reduction are recommended.


Assuntos
Butadienos , Poluentes Químicos da Água , Purificação da Água/métodos , Animais , Biodegradação Ambiental , Biotransformação , Butadienos/análise , Butadienos/metabolismo , Butadienos/toxicidade , Ecossistema , Água Doce/química , Humanos , Oxirredução , Águas Residuárias/química , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/metabolismo , Poluentes Químicos da Água/toxicidade
12.
Ann Work Expo Health ; 63(5): 533-545, 2019 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-31111145

RESUMO

AIMS: The main aim of this study was to assess dermal exposure to polycyclic aromatic hydrocarbons (PAHs) and airway exposure to PAHs, volatile organic compounds (VOCs; benzene and 1,3-butadiene), and particles among firefighters (FFs) and police forensic investigators (PFIs) in Sweden. METHODS: Active (pump with a filter and sorbent tube) and passive (polyurethane foam -cyl and perkin elmer carbopack-tube) personal air sampling and dermal tape stripping (wrist and collar bone) were performed on seven FF team leaders during training fires and nine PFIs investigating the aftermath of live fire events. In addition, passive personal air sampling was performed on eight FF team leaders during live emergency fires. PAHs and VOCs were analysed using high-resolution gas chromatography low-resolution mass spectrometry. The mass concentration of total dust (particles) was determined using standard gravimetric methods. RESULTS: The air samples showed that the exposure to PAHs, benzene, 1,3-butadiene, and particles was below Swedish occupational exposure limits (OELs). Naphthalene was the predominant PAH in all air samples. Benzene and 1,3-butadiene were more abundant in live emergency fires, which caused higher exposures than the other studied situations. Both gaseous- and particle-associated PAHs were present on skin. The wrists seemed to be less well protected than the collarbone area. CONCLUSIONS: FFs and PFIs are exposed to several hazardous compounds during their work. Air exposures varied considerably between working scenarios. The observed exposures were substantially higher than urban background levels but well below Swedish OELs. The measured dermal PAH exposures were comparable to previously reported doses for US FFs but lower than the exposures reported for Swedish chimney sweeps.


Assuntos
Poluentes Ocupacionais do Ar/análise , Monitoramento Ambiental/métodos , Bombeiros , Exposição Ocupacional/análise , Polícia , Hidrocarbonetos Policíclicos Aromáticos/análise , Compostos Orgânicos Voláteis/análise , Adulto , Benzeno/análise , Butadienos/análise , Poeira/análise , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Gases/análise , Humanos , Masculino , Pessoa de Meia-Idade , Suécia
13.
J Environ Sci (China) ; 79: 1-10, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30784434

RESUMO

Methacrolein (MACR) and methyl vinyl ketone (MVK) are two major intermediate products from the photochemical oxidation of isoprene, the most important biogenic volatile organic compound. In addition, MACR and MVK have primary emissions. Investigating the sources and evolution of MACR and MVK could provide helpful information for the oxidative capacity of the atmosphere. In this study, hourly measurements of isoprene, MACR, and MVK were conducted at a receptor site in the Pearl River Delta region (PRD), i.e., the Heshan site (HS), from 22 October to 20 November, 2014. The average mixing ratios of isoprene, MACR and MVK were 151 ±â€¯17, 91 ±â€¯6 and 79 ±â€¯6 pptv, respectively. The daily variations and the ratios of MVK/MACR during daytime and nighttime suggested that other sources besides isoprene photooxidation influenced the MACR and MVK abundances at the HS. Positive matrix factorization was utilized to resolve the sources of MACR and MVK. Five sources were identified and quantified, including biogenic emissions, biomass burning, secondary formation, diesel, and gasoline vehicular emissions. Among them, secondary formation made the greatest contribution to observed MACR and MVK with average contributions of ~45% and ~70%, respectively. Through the yields of secondary products from the oxidation of MACR and MVK by the OH radical and the concentrations of MACR and MVK, it was found that methylglyoxal and formaldehyde were the main oxidation products of MACR and MVK at the HS site. Overall, this study evaluated the roles of primary emissions on ambient levels of MACR and MVK and advanced the understanding of photochemical oxidation of MACR and MVK in the PRD.


Assuntos
Acroleína/análogos & derivados , Poluentes Atmosféricos/análise , Butadienos/análise , Butanonas/análise , Hemiterpenos/análise , Acroleína/análise , Acroleína/química , Poluentes Atmosféricos/química , Biomassa , Butanonas/química , China , Monitoramento Ambiental , Formaldeído/química , Gasolina , Modelos Teóricos , Oxirredução , Aldeído Pirúvico/química , Emissões de Veículos
14.
J Chromatogr A ; 1572: 27-36, 2018 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-30195860

RESUMO

A novel non-silicon-based micro-preconcentration device, as a pretreatment component in a portable gas chromatography system, was developed for the preconcentration one of the trace volatile organic compounds (VOCs) in the exhaled gases, which is one typical biomarker for the chronic liver disease (CLD). The device was designed as an array of manifold-shaped rectangular metal micro-channels with flat dimensions of 16 mm × 12.6 mm and the internal empty volume is 14.4 µL on the copper substrate. Instead of the non-silicon fabrication process, the traditional laser etching technology (LET) was optimized to etch micro-channels, and vacuum diffusion welding (VDW) was applied to form internal channels. The fabricated chip was filled with Carbopack X adsorbent. In the testing, the metal gas preconcentrator (MGP) was installed in a commercial GC (gas chromatography) and nitrogen was used as carrier gas and desorbed gas. With the MPG, up to 352 of concentration factor can be achieved for 10 ppb isoprene. The developed MGP, which has advantages of high strength, low cost, good thermal conductivities, can potentially be used for non-invasive screening of advanced liver fibrosis by monitoring isoprene concentrations in exhaled breath.


Assuntos
Testes Respiratórios/instrumentação , Testes Respiratórios/métodos , Butadienos/análise , Gases/química , Hemiterpenos/análise , Pentanos/análise , Butadienos/isolamento & purificação , Cromatografia Gasosa , Doença Hepática Terminal/diagnóstico , Hemiterpenos/isolamento & purificação , Humanos , Lasers , Metais/química , Pentanos/isolamento & purificação , Vácuo , Compostos Orgânicos Voláteis/análise
15.
ACS Sens ; 3(3): 677-683, 2018 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-29443518

RESUMO

Isoprene is a versatile breath marker for noninvasive monitoring of high blood cholesterol levels as well as for influenza, end-stage renal disease, muscle activity, lung cancer, and liver disease with advanced fibrosis. Its selective detection in complex human breath by portable devices (e.g., metal-oxide gas sensors), however, is still challenging. Here, we present a new filter concept based on activated alumina powder enabling fast and highly selective detection of isoprene at the ppb level and high humidity. The filter contains high surface area adsorbents that retain hydrophilic compounds (e.g., ketones, alcohols, ammonia) representing major interferants in breath while hydrophobic isoprene is not affected. As a proof-of-concept, filters of commercial activated alumina powder are combined with highly sensitive but rather nonspecific, nanostructured Pt-doped SnO2 sensors. This results in fast (10 s) measurement of isoprene down to 5 ppb at 90% relative humidity with outstanding selectivity (>100) to breath-relevant acetone, ammonia, ethanol, and methanol, superior to state-of-the-art isoprene sensors. Most importantly, when exposed continuously to simulated breath mixtures (four analytes) for 8 days, this filter-sensor system showed stable performance. It can be incorporated readily into a portable breath isoprene analyzer promising for simple-in-use monitoring of blood cholesterol or other patho/physiological conditions.


Assuntos
Óxido de Alumínio/química , Butadienos/análise , Filtração/métodos , Hemiterpenos/análise , Humanos , Umidade , Interações Hidrofóbicas e Hidrofílicas , Nanoestruturas/química , Platina/química , Propriedades de Superfície , Compostos de Estanho/química
16.
Waste Manag ; 70: 212-221, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28967530

RESUMO

Due to the continual increase in waste generated from electronic devices, the management of plastics, which represents between 10 and 30% by weight of waste electrical and electronic equipment (WEEE or e-waste), becomes indispensable in terms of environmental and economic impacts. Considering the importance of acrylonitrile-butadiene-styrene (ABS), polycarbonate (PC), and their blends in the electronics and other industries, this study presents a new application of laser-induced breakdown spectroscopy (LIBS) for the fast and direct determination of PC and ABS concentrations in blends of these plastics obtained from samples of e-waste. From the LIBS spectra acquired for the PC/ABS blend, multivariate calibration models were built using partial least squares (PLS) regression. In general, it was possible to infer that the relative errors between the theoretical or reference and predicted values for the spiked samples were lower than 10%.


Assuntos
Acrilonitrila/análise , Butadienos/análise , Resíduo Eletrônico/análise , Plásticos/química , Cimento de Policarboxilato/análise , Poliestirenos/análise , Gerenciamento de Resíduos/métodos , Lasers , Análise Espectral
17.
J Breath Res ; 12(1): 016002, 2017 11 29.
Artigo em Inglês | MEDLINE | ID: mdl-28781264

RESUMO

A study has been carried out on the volatile organic compounds (VOCs) in the exhaled breath of patients suffering from inflammatory bowel disease (IBD), comprising 136 with Crohn's disease (CD) and 51 with ulcerative colitis (UC), together with a cohort of 14 healthy persons as controls. Breath samples were collected by requesting the patients to inflate Nalophan bags, which were then quantitatively analysed using selected ion flow tube mass spectrometry (SIFT-MS). Initially, the focus was on n-pentane that had previously been quantified in single exhalations on-line to SIFT-MS for smaller cohorts of IBD patients. It was seen that the median concentration of pentane was elevated in the bag breath samples of the IBD patients compared to those of the healthy controls, in accordance with the previous study. However, the absolute median pentane concentrations in the bag samples were about a factor of two lower than those in the directly analysed single exhalations-a good illustration of the dilution of VOCs in the samples of breath collected into bags. Accounting for this dilution effect, the concentrations of the common breath VOCs, ethanol, propanol, acetone and isoprene, were largely as expected for healthy controls. The concentrations of the much less frequently measured hydrogen sulphide, acetic acid, propanoic acid and butanoic acid were seen to be more widely spread in the exhaled breath of the IBD patients compared to those for the healthy controls. The relative concentrations of pentane and these other VOCs weakly correlate with simple clinical activity indices. It is speculated that, potentially, hydrogen sulphide and these carboxylic acids could be exhaled breath biomarkers of intestinal bacterial overgrowth, which could assist therapeutic intervention and thus alleviate the symptoms of IBD.


Assuntos
Testes Respiratórios/métodos , Ácidos Carboxílicos/análise , Colite Ulcerativa/diagnóstico , Doença de Crohn/diagnóstico , Expiração , Pentanos/análise , Compostos Orgânicos Voláteis/análise , Ácido Acético/análise , Adolescente , Adulto , Idoso , Biomarcadores/análise , Butadienos/análise , Feminino , Hemiterpenos/análise , Humanos , Sulfeto de Hidrogênio/análise , Masculino , Pessoa de Meia-Idade , Vapor/análise , Adulto Jovem
18.
Int Arch Occup Environ Health ; 90(7): 713-724, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28578463

RESUMO

PURPOSE: Petroleum refinery workers are exposed to the carcinogens benzene and 1,3-butadiene. Declining exposures have been reported internationally but information on current exposure in the Swedish refinery industry is limited. The aim was to examine refinery workers' personal exposure to benzene and 1,3-butadiene and increase awareness of exposure conditions by collaboration with involved refineries. METHODS: Altogether 505 repeated personal exposure measurements were performed among workers at two refineries. Full-shift measurements were conducted in different exposure groups using Perkin Elmer diffusive samplers filled with Carbopack X. Mean levels were calculated using mixed-effects models. A large fraction of measurements below the limit of detection (LOD) required imputation of computer-generated data. RESULTS: Mean benzene exposure among process technicians was 15.3 µg/m3 (95% CI 10.4-22.5 µg/m3) and 13.7 µg/m3 (95% CI 8.3-22.7 µg/m3) for Refinery 1 and 2, respectively. Process technicians working outdoors had higher exposure than maintenance workers (20.7 versus 5.9 µg/m3, p < 0.01). Working in the harbour and tank park (Refinery 1), compared with the process area, was associated with higher exposure. The 1,3-butadiene exposure was low, 5.4 and 1.8 µg/m3, respectively. The total variation was generally attributed to within-worker variability. CONCLUSIONS: Low benzene and 1,3-butadiene levels were found among refinery workers. Mean benzene exposure was about 1% of the Swedish occupational limit (1500 µg/m3) and for 1,3-butadiene, exposure was even lower. A large fraction of values below the LOD can be managed by carefully modelled, computer-generated data.


Assuntos
Poluentes Ocupacionais do Ar/análise , Benzeno/análise , Butadienos/análise , Exposição Ocupacional/análise , Indústria de Petróleo e Gás , Monitoramento Ambiental/métodos , Humanos , Exposição por Inalação/análise , Ocupações/estatística & dados numéricos , Suécia
19.
Scand J Work Environ Health ; 43(5): 494-503, 2017 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-28489219

RESUMO

Objectives 1,3-butadiene is classified as carcinogenic to human by inhalation and the association with leukemia has been observed in several epidemiological studies. The aim of this study was to evaluate data about occupational exposure levels to 1,3-butadiene in the Italian working force. Methods Airborne concentrations of 1,3-butadiene were extracted from the Italian database on occupational exposure to carcinogens in the period 1996-2015. Descriptive statistics were calculated for exposure-related variables. An analysis through linear mixed model was performed to determine factors influencing the exposure level. The probability of exceeding the exposure limit was predicted using a mixed-effects logistic model. Concurrent exposures with other occupational carcinogens were investigated using the two-step cluster analysis. Results The total number of exposure measurements selected was 23 885, with an overall arithmetic mean of 0.12 mg/m3. The economic sector with the highest number of measurements was manufacturing of chemicals (18 744). The most predictive variables of the exposure level resulted to be the occupational group and its interaction with the measurement year. The highest likelihood of exceeding the exposure limit was found in the manufacture of coke and refined petroleum products. Concurrent exposures were frequently detected, mainly with benzene, acrylonitrile and ethylene dichloride, and three main clusters were identified. Conclusions Exposure to 1,3-butadiene occurs in a wide variety of activity sectors and occupational groups. The use of several statistical analysis methods applied to occupational exposure databases can help to identify exposure situations at high risk for workers' health and better target preventive interventions and research projects.


Assuntos
Poluentes Ocupacionais do Ar/análise , Butadienos/análise , Monitoramento Ambiental/métodos , Exposição Ocupacional/estatística & dados numéricos , Carcinógenos , Feminino , Humanos , Itália , Masculino , Modelos Estatísticos , Saúde Ocupacional , Ocupações/estatística & dados numéricos , Indústria de Petróleo e Gás/estatística & dados numéricos
20.
J Chromatogr A ; 1500: 153-159, 2017 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-28442132

RESUMO

We introduce a gas chromatography detection approach that uses diode array detection operated in series with flame ionisation detection and demonstrate the utility of the detection approach for determination of volatile organic compounds. Diode array detection brings ultraviolet - visible spectroscopy (over a range of 190-640nm) onto the capillary gas chromatography time-scale, where average peak widths of analytes are on the order of 3-5s. The non-destructive nature of the diode array detector affords serially-coupled flame ionisation detection. This arrangement delivers near-simultaneous selective and universal detection without incurring additional analytical time, and without recourse to column flow splitting. The hyphenated technique is shown to be effective for chromatographic applications spanning an equivalent volatility range from C1 to C7n-paraffin hydrocarbons. The approach introduced herein provides increased sensitivity and selectivity for classes of compounds amenable to electronic spectroscopy such as alkenes, dienes, sulfurs, and aromatic compounds. The approach is demonstrated for direct measurement of carbon disulfide in work place atmospheres with a detection limit of 93pg on column and for the direct measurement of 1,3-butadiene in hydrocarbon matrices and ambient air with a detection of 73pg on column, each in less than 5min.


Assuntos
Cromatografia Gasosa/métodos , Ionização de Chama/métodos , Butadienos/análise , Cromatografia Gasosa/instrumentação , Ionização de Chama/instrumentação , Hidrocarbonetos/análise , Limite de Detecção , Parafina/análise , Compostos Orgânicos Voláteis/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA