Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.719
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Refract Surg ; 40(5): e304-e312, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717085

RESUMO

PURPOSE: To compare intraoperative performance and early postoperative outcomes following phacoemulsification with two systems using active fluidics and one using gravity-based fluidics. METHODS: In this prospective randomized trial, 200 eyes were randomized to the traditional and Active Sentry groups (n = 80 eyes each) where the Centurion Vision System was used with traditional or Active Sentry (Alcon Laboratories, Inc) hand-pieces, respectively, or the Infinit group (n = 40 eyes) where the Infiniti Vision System (Alcon Laboratories, Inc) was used. Within the traditional and Active Sentry groups, there were two subgroups with low (30 mm Hg) or high (55 mm Hg) intraocular pressure (IOP) used. Outcome measures compared were: cumulative dissipated energy (CDE), percentage change in central corneal thickness (CCT) at 1 day, 1 week, and 1 month, anterior chamber cells at 1 day and 1 week, rate of rise and fall of IOP following occlusion break, corneal endothelial cell density (ECD), and macular thickness 6 months postoperatively. RESULTS: CDE was significantly lower in group II compared to the traditional group (2.96 ± 1.4 vs 4.14 ± 2.2, P = .001). With 30 mm Hg IOP, the Active Sentry group had significantly less percentage change in CCT at 1 week postoperatively compared to the traditional handpiece group (0.01% vs 0.02%, P = .008). Incidence of anterior chamber cells less than grade 2 on day 1 was significantly higher in the Active Sentry group (82.9% vs 52%, P = .03). Percentage change in ECD was significantly lower in the Active Sentry group (-0.957 vs -0.98%, P = .005). Significantly faster rise of IOP to baseline following occlusion break was seen in the Active Sentry group. CONCLUSIONS: The use of Active Sentry handpiece was associated with lower CDE, less postoperative increase in CCT, fewer anterior chamber cells, and faster rise of IOP following occlusion break. [J Refract Surg. 2024;40(5):e304-e312.].


Assuntos
Pressão Intraocular , Implante de Lente Intraocular , Facoemulsificação , Acuidade Visual , Humanos , Estudos Prospectivos , Pressão Intraocular/fisiologia , Masculino , Feminino , Idoso , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Endotélio Corneano/patologia , Contagem de Células , Período Pós-Operatório , Tomografia de Coerência Óptica , Hidrodinâmica , Câmara Anterior , Período Intraoperatório
3.
Indian J Ophthalmol ; 72(6): 916-918, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38767550

RESUMO

Phacoemulsification in hard cataracts is a challenge. The use of dispersive ophthalmic viscosurgical devices (OVDs) to protect the endothelium is a routine step in such scenarios. However, as OVD is transparent, it is difficult to spot within the anterior chamber. Therefore, surgeons may not be aware when the OVD coating of the endothelium disappears during surgery. Consequently, there may be too frequent OVD injections, resulting in a waste of resources. On the contrary, the surgeon may fail to inject OVD at an appropriate time, leading to greater endothelial damage. We propose a novel technique of using an air bubble as a guide that helps in identifying the time when OVD disappears from the anterior chamber, thereby suggesting the surgeon to reinject before proceeding further.


Assuntos
Ar , Facoemulsificação , Viscossuplementos , Humanos , Facoemulsificação/métodos , Viscossuplementos/administração & dosagem , Ácido Hialurônico/administração & dosagem , Endotélio Corneano/patologia , Câmara Anterior
4.
Vet Med Sci ; 10(4): e1448, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38818763

RESUMO

BACKGROUND: Recombinant intracameral tissue plasminogen activator (rTPA) administration can aid clearance of fibrin from the anterior chamber. MATERIALS AND METHODS: In this retrospective multicentre case series, the effect of intracameral rTPA administration to treat fibrin in the anterior chamber resulting from trauma or inflammatory ocular disease was evaluated. Clinical data from 30 treatments in 29 horses were obtained from medical records from 2003 to 2022. Association between time from onset of clinical signs and time for rTPA treatment to effect was studied with regression analysis. RESULTS: Twenty-seven horses (93.1%) had no previous history of ophthalmic disease; one had an iridic cyst, and another had equine recurrent uveitis. The majority of cases were related to trauma (79.3%). Median time from the onset of clinical signs to treatment was 12 h (IQR = 4-48 h). rTPA (72% 20 µg; 24% 25 µg; 3.3% 40 µg) was administered once in all but one eye, which was treated twice. Resolution of fibrin was seen in 96.9% (29/30) of treatments. Fibrin accumulation recurred in one case but resolved 14 days after the second treatment. Complications were seen in four treatments (13.3%): moderate pain for 24 h, intracameral debris and mild intracameral haemorrhage in a horse that received 40 µg of tissue plasminogen activator. Recurrence of fibrin accumulation was absent in 96.7% of cases. Median time to effect was 20 min (IQR = 10-45 min). Time for rTPA treatment to effect was not associated with time from fibrin formation (R2 = 0.09; p = 0.11). CONCLUSION: Intracameral rTPA treatment can be considered at 20-25 µg in 0.1 mL solution to aid resolution of fibrin accumulation.


Assuntos
Câmara Anterior , Fibrina , Doenças dos Cavalos , Ativador de Plasminogênio Tecidual , Animais , Cavalos , Ativador de Plasminogênio Tecidual/administração & dosagem , Doenças dos Cavalos/tratamento farmacológico , Estudos Retrospectivos , Feminino , Masculino , Câmara Anterior/efeitos dos fármacos , Fibrinolíticos/farmacologia , Fibrinolíticos/administração & dosagem , Proteínas Recombinantes/administração & dosagem , Proteínas Recombinantes/uso terapêutico , Oftalmopatias/veterinária , Oftalmopatias/tratamento farmacológico
5.
Sci Rep ; 14(1): 8279, 2024 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594403

RESUMO

The aim of the study was to compare the anterior segment parameters after cataract surgery in pseudoexfoliation syndrome (PEX) and control eyes. We conducted a prospective comparative study of 36 eyes (PEX group), 16 eyes (PEXG group) and 46 eyes (control group) of 98 patients after phacoemulsification with intraocular lens implantation. Before surgery, 1 week, 1 month and 3 months postoperatively, anterior chamber parameters were evaluated by swept source anterior segment optical coherence tomography (AS-OCT). Anterior chamber depth (ACD), angle opening distance (AOD500/750), trabecular-iris space area (TISA500/750), trabecular-iris angle (TIA500/750) and lens vault (LV) were assessed at each study visit. Preoperatively, ACD, AOD500/750 and TISA500/750 were significantly smaller, while LV was significantly greater in PEX and PEXG eyes than in controls. 3 months postoperatively all irido-corneal parameters and ACD were significantly greater in all study groups without intergroup differences. ACD and LV significantly increased in PEX group between 1 and 3 months after surgery while being stable in control group. Relative increases in ACD, AOD500, TISA750, TIA500/750 were significantly higher in PEX and PEXG groups than in controls. Our study finds that ACD and iridocorneal parameters in AS-OCT demonstrated significantly greater relative increases 3 months after phacoemulsification in PEX and PEXG groups than in control eyes. Significantly greater deepening of anterior chamber and opening of the irido-corneal angle may be a reason for different refractive outcomes and IOP control in patients with PEX and PEXG after routine cataract surgery.


Assuntos
Catarata , Síndrome de Exfoliação , Humanos , Tomografia de Coerência Óptica/métodos , Síndrome de Exfoliação/diagnóstico por imagem , Estudos Prospectivos , Pressão Intraocular , Câmara Anterior , Segmento Anterior do Olho/diagnóstico por imagem
6.
Sci Rep ; 14(1): 8305, 2024 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594402

RESUMO

To investigate the associations between corneal curvature (CC) and other anterior segment biometrics in young myopic adults. In this retrospective multi-center study, 7893 young myopic adults were included. CC and other anterior segment biometrics were measured by Scheimpflug imaging (Pentacam). CC was defined as SimK at central 3 mm area, and other anterior segment biometrics included white-to-white corneal diameter (WTW), central corneal thickness (CCT), corneal volume (CV) at 3 mm, 5 mm, and 7 mm area, anterior corneal astigmatism (ACA), posterior corneal astigmatism (PCA), anterior corneal eccentricity (ACE) and asphericity (ACAP), posterior corneal eccentricity (PCE) and asphericity (PCAP), anterior chamber depth (ACD), and anterior chamber volume (ACV). Univariate regression analyses were used to assess the associations between CC and other anterior segment biometrics, and multivariate regression analyses were further performed to adjusted for age, gender and spherical equivalent. CC was higher in patients of female gender and higher myopia (all P < 0.05). Eyes in higher CC quartiles had lower WTW, thinner CCT, lower CV at 3 mm and 5 mm, lower ACD, and lower ACV (all P < 0.001), but had larger ACA, larger PCA, less PCE and less PCAP (all P < 0.001), compared to eyes in lower CC quartiles. The trends of CV at 7 mm, ACE and ACAP were inconsistent in different CC quartiles. After adjusting for age, gender and spherical equivalent with multivariate linear regression, CC was positively correlated to CV at 7 mm (ßs = 0.069), ACA (ßs = 0.194), PCA (ßs = 0.187), ACE (ßs = 0.072), PCAP (ßs = 0.087), and ACD (ßs = 0.027) (all P < 0.05), but was negatively correlated to WTW (ßs = - 0.432), CCT (ßs = - 0.087), CV-3 mm (ßs = - 0.066), ACAP (ßs = - 0.043), PCE (ßs = - 0.062), and ACV (ßs = - 0.188) (all P < 0.05). CC was associated with most of the other anterior segment biometrics in young myopic adults. These associations are important for better understanding of the interactions between different anterior segment structures in young myopic patients, and are also useful for the exploration of the pathogenesis of myopia.


Assuntos
Astigmatismo , Doenças da Córnea , Miopia , Adulto , Feminino , Humanos , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/patologia , Astigmatismo/patologia , Biometria , Córnea/patologia , Doenças da Córnea/patologia , Miopia/patologia , Estudos Retrospectivos
7.
Transl Vis Sci Technol ; 13(4): 11, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38578634

RESUMO

Background: The purpose of this study was to explore the protective effect of a shape memory polymeric shield on corneal endothelium during phacoemulsification in rabbits. Methods: Poly-(glycerol dodecanedioate) (PGD) with a transition temperature of 24.416°C was prepared to make a shape memory shield with a thickness of 100 µm, an arc length of 14 mm, and a radius of curvature of 8.8 mm. In the control group, a phaco-tip with bevel-down was used to simulate injury to the corneal endothelium by phacoemulsification in rabbits. In the experimental group, the pre-cooled and curled shape memory shield was injected into and removed from the anterior chamber before and after phaco-power release. Anterior segment optical coherence tomography (AS-OCT), confocal microscope, trypan blue/alizarin red staining, and scanning electron microscope were performed to measure endothelial damage after surgery. Results: One day postoperatively, the lost cell ratio of the control group and the experimental group were 28.08 ± 5.21% and 3.50 ± 1.43%, respectively (P < 0.0001), the damaged cell ratios were 11.83 ± 2.30% and 2.55 ± 0.52%, respectively (P < 0.0001), and the central corneal thicknesses (CCT) were 406.75 ± 16.74 µm and 340. 5 ±13.48 µm, respectively (P < 0.0001). Seven days postoperatively, the endothelial cell density (ECD) of the control group and the experimental group were 1674 ± 285/mm2 and 2561 ± 554/mm2, respectively (P < 0.05). The above differences were all statistically significant. Conclusions: This PGD based shape memory shield has a protective effect on corneal endothelium during phacoemulsification. It reduces postoperative corneal edema and ECD decrease in the short term after surgery. Translational Relevance: The shape memory PGD "shield" in this study may have a use in certain human patients with vulnerable corneas of low endothelial cell count or shallow anterior chambers.


Assuntos
Endotélio Corneano , Facoemulsificação , Animais , Humanos , Coelhos , Facoemulsificação/efeitos adversos , Facoemulsificação/métodos , Córnea , Câmara Anterior
8.
Trials ; 25(1): 287, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38679725

RESUMO

BACKGROUND: Neovascular glaucoma (NVG) is an irreversible blinding eye disease worldwide and is classified as one of the refractory glaucoma conditions, severely impacting visual function and vision. Unfortunately, effective surgical interventions to improve the prognosis of NVG patients are currently lacking. The study aims to evaluate the efficacy and safety of anterior chamber proliferative membrane interception (AC-PMI)-enhanced trabeculectomy compared to the traditional trabeculectomy. METHODS: AC-PMI enhanced trabeculectomy versus trabeculectomy for the treatment of NVG is a single-center, prospective, double-arms, and randomized controlled trial of superior efficacy, which will involve 100 NVG inpatients. Patients will be randomly assigned into two groups using the random number table method. One group will undergo trabeculectomy using anti-vascular endothelial growth factor (Anti-VEGF) preoperatively and mitomycin C intraoperatively, while the other group will undergo AC-PMI enhanced trabeculectomy with the same medications (Anti-VEGF and mitomycin C). The patients will be followed up at the baseline and 1 day, 1 week, 1 month, 3 months, 6 months, 12 months, 18 months, and 24 months postoperatively. Meanwhile, we will collect the demographics, characteristics, and examination results and monitor any occurrences of adverse events at each follow-up time. DISCUSSION: This is an efficacy study of a novel surgical approach for treating neovascular glaucoma. Building upon conventional filtering surgeries, this approach introduces an additional step involving the interception of the proliferative membrane to effectively halt the growth of fibrovascular tissue. This study aims to explore a promising new surgical approach for managing NVG and contribute to the advancement of glaucoma treatment strategies. TRIAL REGISTRATION: ChiCTR ChiCTR2200055138. Registered on 01 January 2022. https://www.chictr.org.cn/showproj.html?proj=145255.


Assuntos
Glaucoma Neovascular , Ensaios Clínicos Controlados Aleatórios como Assunto , Trabeculectomia , Fator A de Crescimento do Endotélio Vascular , Humanos , Trabeculectomia/métodos , Trabeculectomia/efeitos adversos , Glaucoma Neovascular/cirurgia , Glaucoma Neovascular/fisiopatologia , Estudos Prospectivos , Resultado do Tratamento , Pessoa de Meia-Idade , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Idoso , Feminino , Masculino , Adulto , Câmara Anterior/cirurgia , Pressão Intraocular , Mitomicina/uso terapêutico , Mitomicina/administração & dosagem , Inibidores da Angiogênese/uso terapêutico , Inibidores da Angiogênese/administração & dosagem , Adulto Jovem
10.
J AAPOS ; 28(3): 103922, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38679138

RESUMO

PURPOSE: To report the long-term clinical and endothelial cell count (ECC) results of lensectomy with primary anterior chamber iris claw lens implantation in the eyes of patients ≤18-year-old with ectopia lentis due to Marfan syndrome. METHODS: The medical records of Marfan patients operated on at a single institution from September 2007 to August 2020, with minimum follow-up of 2 years, were reviewed retrospectively. The following data were analyzed: sex, age at surgery, indication for surgery, the position of the lens in relation to the undilated and dilated pupil, corneal endothelial cell counts (ECC), peri- and postoperative complications, pre- and postoperative best-corrected visual acuity. RESULTS: A total of forty-two eyes of 23 patients (12 girls and 11 boys) were included. At least two or more postoperative ECCs were collected from 33 eyes (17 patients). Median age at IOL implantation was 6.1 years (range, 1.8-18). Median overall follow-up time was 6.2 years (range, 2-13.5). Median ECC follow-up time was 6.2 years (range, 2-10). Mean best-corrected visual acuity was 0.71 ± 0.38 logMAR before surgery and 0.02 ± 0.25 logMAR at final follow-up. The mean annual ECC decline was 0.71% ± 2.24. Total cell loss from first to last postoperative measurement was 150 cells ± 394 cells/mm2 (4.81%). Pre- and first postoperative data were available for 17 eyes of 10 patients, with a mean cell loss before and directly after surgery of 269 ± 268 cells (7.94%). Surgery related complications were iris bombé due to blockage of peripheral iridectomy in 3 eyes and claw dislocation due to direct impact trauma in 3 eyes. CONCLUSIONS: In our large, pediatric study cohort, anterior chamber iris claw IOL implantation resulted in an excellent visual outcome and normal endothelial cell loss compared with normative data. Safety measures are recommended to avoid traumatic dislocation of IOLs.


Assuntos
Câmara Anterior , Ectopia do Cristalino , Iris , Implante de Lente Intraocular , Síndrome de Marfan , Acuidade Visual , Humanos , Ectopia do Cristalino/cirurgia , Síndrome de Marfan/complicações , Síndrome de Marfan/cirurgia , Feminino , Masculino , Criança , Implante de Lente Intraocular/métodos , Estudos Retrospectivos , Acuidade Visual/fisiologia , Pré-Escolar , Adolescente , Iris/cirurgia , Câmara Anterior/patologia , Seguimentos , Lactente , Lentes Intraoculares , Complicações Pós-Operatórias , Endotélio Corneano/patologia , Contagem de Células
12.
Transl Vis Sci Technol ; 13(3): 23, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38536170

RESUMO

Purpose: To compare aqueous humor outflow (AHO) pathway patterns between eyes of childhood glaucoma patients and non-glaucomatous patients receiving cataract surgery. Methods: Aqueous angiography was performed in childhood glaucoma eyes (n = 5) receiving glaucoma surgery and in pediatric (n = 1) and healthy adult (n = 5) eyes receiving cataract surgery. Indocyanine green (0.4%) was introduced into the anterior chamber, and AHO was imaged using an angiographic camera (SPECTRALIS HRA+OCT with Flex Module). Images were acquired and analyzed (ImageJ with Analyze Skeleton 2D/3D plugin) from the nasal sides of the eyes, the usual site of glaucoma angle procedures. Image analysis endpoints included AHO vessel length, maximum vessel length, number of branches, number of branch junctions, and vessel density. Results: Qualitatively, childhood glaucoma eyes demonstrated lesser AHO pathway arborization compared to pediatric and adult eyes without glaucoma. Quantitatively, childhood glaucoma and healthy adult cataract eyes showed similar AHO pathway average branch lengths and maximum branch lengths (P = 0.49-0.99). However, childhood glaucoma eyes demonstrated fewer branches (childhood glaucoma, 198.2 ± 35.3; adult cataract, 506 ± 59.5; P = 0.002), fewer branch junctions (childhood glaucoma, 74.6 ± 13.9; adult cataract, 202 ± 41.2; P = 0.019), and lower vessel densities (childhood glaucoma, 8% ± 1.4%; adult cataract, 17% ± 2.5%; P = 0.01). Conclusions: Childhood glaucoma patients demonstrated fewer distal AHO pathways and lesser AHO pathway arborization. These anatomical alternations may result in a new source of trabecular meshwork-independent AHO resistance in this disease cohort. Translational Relevance: Elevated distal outflow pathway resistance due to decreased AHO pathway arborization may explain some cases of failed trabecular bypass surgery in childhood glaucoma.


Assuntos
Catarata , Glaucoma , Adulto , Humanos , Criança , Humor Aquoso , Câmara Anterior , Angiografia
15.
BMJ Case Rep ; 17(3)2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38479826

RESUMO

A woman in her 60s presented with diminution of vision and redness in her right eye (OD) 1.5 months duration, 10 months post cataract surgery. The best-corrected visual acuity (BCVA) on the OD was fingers counting at 0.5 m. The anterior section of the OD demonstrated superior pre-Descemet's intrastromal bleeding, superior dense fibrovascular growth in the corneal mid-stroma and superior fibrovascular downgrowth measuring 5×5 mm in the anterior chamber. Along with topical prednisolone acetate (1%) suspension 4 times per day on a tapering dose, antivascular endothelial growth factor therapy was administered intrastromally and subconjunctivally in the superior bulbar conjunctiva near limbus (0.05 mL of 2.5 mg/0.1 mL at each site). Over the course of a week, the intrastromal bleed had completely stopped. Three months later, at the final follow-up, the BCVA had marginally improved to fingers counting 2 m, with a lingering 4×4 mm nebulomacular scar.


Assuntos
Extração de Catarata , Feminino , Humanos , Extração de Catarata/efeitos adversos , Substância Própria , Câmara Anterior , Imagem Multimodal
16.
J Refract Surg ; 40(3): e182-e194, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38466762

RESUMO

PURPOSE: To provide an up-to-date review of the agreement in automated white-to-white (WTW) measurement between the latest topographic and biometric devices. METHODS: In this systematic review, PubMed, Web of Science, and Scopus databases were searched for articles published between 2017 and 2023, focusing on WTW agreement studies on adult, virgin eyes, with or without cataract and no other ocular comorbidities. Studies evaluating WTW measurements performed with autokeratometers, manual calipers, or manual image analysis were excluded. When available, the following metrics for the agreement of WTW measurements between pairs of devices were included: mean difference ± standard deviation, 95% limits of agreement (LoA), LoA width, 95% confidence interval (95 CI%), and intraclass correlation coefficient (ICC). RESULTS: Forty-one studies, covering comparisons for 19 devices, were included. Altogether, 81 paired comparisons were performed for 4,595 eyes of 4,002 individuals. The mean difference in WTW measurements between devices ranged from 0.01 mm up to 0.96 mm, with varying CI. The 95% LoA width ranged from 0.31 to 2.45 mm (median: 0.65 mm). The majority of pairwise comparisons reported LoA wider than 0.5 mm, a clinically significant value for phakic intraocular lens sizing. CONCLUSIONS: Nearly all analyzed studies demonstrated the lack of interchangeability of the WTW parameter. The corneal diameter, assessed by means of grayscale en-face image analysis, tended to demonstrate the lowest agreement among devices compared to other measured biometric parameters. [J Refract Surg. 2024;40(3):e182-e194.].


Assuntos
Córnea , Lentes Intraoculares Fácicas , Adulto , Humanos , Topografia da Córnea/métodos , Câmara Anterior , Biometria/métodos , Reprodutibilidade dos Testes
17.
J Refract Surg ; 40(3): e164-e172, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38466765

RESUMO

PURPOSE: To evaluate the dynamic changes in anterior segment parameters during accommodation following Implantable Collamer Lens (ICL) implantation with swept-source optical coherence tomography (SS-OCT). METHODS: Under the accommodation of 0.00 diopters (D), 3.00 D, and maximum amplitude, SS-OCT was used to examine the anterior segment parameters, including ICL vault, ICL depth (the distance between the corneal endothelium and the posterior surface of ICL), crystalline lens thickness, anterior chamber depth, and various parameters of the anterior chamber angle, comprising angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle. RESULTS: During accommodation, the ICL vault showed a significant decrease from baseline (536 ± 278 µm) to 3.00 D (522 ± 281 µm), followed by an increase from 3.00 D to maximum amplitude (548 ± 306 µm) (analysis of variance [ANOVA], P < .001). Four eyes (2.61%) exhibited a decrease in ICL vault to less than 100 µm (47 ± 32 µm) at maximum accommodation. The ICL depth decreased significantly as accommodation increased (ANOVA, P < .001). Crystalline lens thickness increased, whereas anterior chamber depth decreased during accommodation (ANOVA, P < .001). The anterior chamber angle widened during 3.00 D of accommodation but narrowed at maximum accommodation, leading to significant changes in the angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle during accommodation (ANOVA, P < .001 for all). CONCLUSIONS: The anterior segment, including ICL vault and anterior chamber angle, undergo significant dynamic changes during accommodation. These accommodative changes may require careful monitoring for the surgery design of ICL implantation. [J Refract Surg. 2024;40(3):e164-e172.].


Assuntos
Cristalino , Miopia , Lentes Intraoculares Fácicas , Humanos , Implante de Lente Intraocular/métodos , Miopia/cirurgia , Acomodação Ocular , Câmara Anterior/diagnóstico por imagem , Pseudofacia/cirurgia , Tomografia de Coerência Óptica , Biometria
18.
Sci Rep ; 14(1): 4452, 2024 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-38396005

RESUMO

To carry out the preclinical and histological evaluation of a novel nanotechnology-based microshunt for drainage glaucoma surgery. Twelve New Zealand White rabbits were implanted with a novel microshunt and followed up for 6 weeks. The new material composite consists of the silicone polydimethylsiloxane (PDMS) and tetrapodal Zinc Oxide (ZnO-T) nano-/microparticles. The microshunts were inserted ab externo to connect the subconjunctival space with the anterior chamber. Animals were euthanized after 2 and 6 weeks for histological evaluation. Ocular health and implant position were assessed at postoperative days 1, 3, 7 and twice a week thereafter by slit lamp biomicroscopy. Intraocular pressure (IOP) was measured using rebound tonometry. A good tolerability was observed in both short- and medium-term follow-up. Intraocular pressure was reduced following surgery but increased to preoperative levels after 2 weeks. No clinical or histological signs of inflammatory or toxic reactions were seen; the fibrotic encapsulation was barely noticeable after two weeks and very mild after six weeks. The new material composite PDMS/ZnO-T is well tolerated and the associated foreign body fibrotic reaction quite mild. The new microshunt reduces the IOP for 2 weeks. Further research will elucidate a tube-like shape to improve and prolong outflow performance and longer follow-up to exclude medium-term adverse effects.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma , Óxido de Zinco , Animais , Coelhos , Implantes para Drenagem de Glaucoma/efeitos adversos , Glaucoma/cirurgia , Glaucoma/etiologia , Pressão Intraocular , Tonometria Ocular , Câmara Anterior/cirurgia , Nanotecnologia
19.
Arch Soc Esp Oftalmol (Engl Ed) ; 99(4): 152-157, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38309658

RESUMO

INTRODUCTION: Lamellar keratoplasties have had a great impact in the management of corneal edema due to endothelial dysfunction. Minimally invasive transplant techniques such as Descemet Membrane Endothelial Keratoplasty (DMEK) have helped to reduce the morbidity involved in performing penetrating keratoplasty in this type of patient. Even so, these are complex techniques that are not free of complications and require a long line of surgical learning and an even more demanding experience in postoperative management. CLINICAL CASE: An 89-year-old woman suffering from Fuchs endothelial dystrophy and undergoing combined cataract and DMEK surgery presented stromal edema predominantly inferior and sectoral detachment of the graft 24 h after the intervention. After re-bubbling in consultations and 4 days later, the graft was observed rolled and free in the anterior chamber. She underwent re-DMEK with preservation of the original graft after 24 h, with de-epithelialization to optimize visualization. The graft was stained with trypan blue and the posterior stroma was protected with air. The graft was reimplanted under intraocular maneuvers and with an air bubble. 24 h after surgery, the adhered graft was observed, with a great decrease in stromal edema. One month later, the patient had a clear cornea, persistent complete graft adhesion, and visual acuity of 0.9. CONCLUSION: The discovery of free roll in the anterior chamber after DMEK surgery constitutes the most complex form of graft detachment. Corneal edema as well as the arrangement of the different intraocular structures are conditions to be considered for the surgical resolution of this complication. In many cases, surgical repositioning of the graft is feasible, which means saving costs without the need to use new donor corneal tissues.


Assuntos
Edema da Córnea , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Feminino , Humanos , Idoso de 80 Anos ou mais , Lâmina Limitante Posterior/cirurgia , Endotélio Corneano , Edema da Córnea/etiologia , Edema da Córnea/cirurgia , Câmara Anterior/cirurgia , Edema
20.
Int Ophthalmol ; 44(1): 62, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38345699

RESUMO

PURPOSE: This study evaluated the relationship between refractive outcomes and postoperative anterior chamber depth (ACD, measured from corneal epithelium to lens) measured by swept-source optical coherence tomography (SS-OCT), optical low-coherence reflectometry (OLCR), and Scheimpflug devices under the undilated pupil. METHODS: Patients undergoing cataract phacoemulsification with intraocular lens (IOL) implantation in a hospital setting were enrolled. Postoperative ACD (postACD) was performed with an SS-OCT device, an OLCR device, and a Scheimpflug device at least 1 month after cataract surgery. After adjusting the mean predicted error to 0, differences in refractive outcomes were calculated with the Olsen formula using actual postACD measured from 3 devices and predicted value. RESULTS: Overall, this comparative case study included 69 eyes of 69 patients, and postACD measurements were successfully taken using all 3 devices. The postACD measured with the SS-OCT, OLCR, and Scheimpflug devices was 4.59 ± 0.30, 4.50 ± 0.30, and 4.54 ± 0.32 mm, respectively. Statistically significant differences in postACD were found among 3 devices (P < 0.001), with intraclass correlation coefficients (ICCs) and Bland-Altman showing good agreement. No significant difference in median absolute error was found with the Olsen formula using actual postACD obtained with 3 devices. Percentage prediction errors were within ± 0.50 D in 65% (OLCR), 70% (Scheimpflug), and 67% (SS-OCT) calculated by actual postACD versus 64% by predicted value. CONCLUSION: Substantial agreement was found in postACD measurements obtained from the SS-OCT, OLCR, and Scheimpflug devices, with a trend toward comparable refractive outcomes in the Olsen formula. Meanwhile, postACD measurements may be potentially superior for the additional enhancement of refractive outcomes.


Assuntos
Catarata , Cristalino , Lentes Intraoculares , Humanos , Câmara Anterior/diagnóstico por imagem , Comprimento Axial do Olho , Refração Ocular , Catarata/diagnóstico , Tomografia de Coerência Óptica/métodos , Biometria/métodos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA