Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.368
Filtrar
1.
BMC Ophthalmol ; 24(1): 212, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38750496

RESUMO

BACKGROUND: To evaluate differences in log MAR best-corrected visual acuity (BCVA) improvement and postoperative central foveal thickness (CFT) and choroidal thickness (CT) changes between conventional phacoemulsification surgery (CPS) and femtosecond laser-assisted cataract surgery (FLACS) for high-myopia cataracts. METHODS: This was a retrospective and observational study. One hundred and two eyes of 102 patients with high-myopia cataracts were examined. CPS was performed in 54 eyes, and FLACS was performed in 48 eyes. All eyes underwent logMAR BCVA, CFT and CT of three different sectors preoperatively and one week and six months postoperatively. RESULTS: The logMAR BCVA improved significantly after surgery in both groups (both P < 0.001), but no difference was observed in BCVA improvement between the groups (P = 0.554). Moreover, no significant differences were reflected in the changes in CFT, nasal 1 mm CT or temporal 1 mm CT between the two groups, and only subfoveal choroidal thickness (SFCT) in the CPS group decreased significantly compared with that in the FLACS group at any postoperative time (P = 0.003 and 0.026). AL, preoperative logMAR BCVA, and CT of the three regions exhibited a notable correlation with postoperative BCVA (all P < 0.05) according to univariate logistic regression analysis. However, only the AL, preoperative logMAR BCVA and SFCT remained significant in the multivariate model. Postoperative logMAR BCVA revealed a positive correlation with AL and preoperative logMAR BCVA but a negative correlation with SFCT. CONCLUSIONS: FLACS was not superior to CPS in improving BCVA but had less impact on SFCT in the treatment of high-myopia cataracts. Eyes with a longer AL, worse preoperative logMAR BCVA and thinner SFCT had a high risk of worse postoperative BCVA.


Assuntos
Catarata , Terapia a Laser , Facoemulsificação , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Estudos Retrospectivos , Feminino , Masculino , Facoemulsificação/métodos , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Idoso , Terapia a Laser/métodos , Catarata/complicações , Catarata/fisiopatologia , Tomografia de Coerência Óptica/métodos , Macula Lutea/diagnóstico por imagem , Macula Lutea/patologia , Extração de Catarata/métodos , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/cirurgia , Miopia Degenerativa/complicações , Corioide/diagnóstico por imagem , Resultado do Tratamento
2.
Int Ophthalmol ; 44(1): 203, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38671195

RESUMO

PURPOSE: This study aimed to observe the tilt and decentration of multifocal intraocular lens (IOL) with optic capture in Berger space within 2 years after pediatric cataract surgery. METHODS: This is a prospective observational study. The implantation of multifocal IOL (Tecnis ZMB00) with optic capture in Berger space was performed on 33 patients (48 eyes) with pediatric cataract at Qingdao Eye Hospital. Tilt and decentration of IOL was measured using Scheimpflug system (Pentacam) at 1 month and 2 years postoperatively. RESULTS: All the multifocal IOLs were successfully implanted in Berger space with optic capture and no visually significant complications were detected during the follow-up. The mean tilt of IOLs was 2.779° ± 0.950° in the vertical plane and 2.399° ± 0.898° in the horizontal plane at 1 month postoperatively, and the mean length of the decentration was 0.207 ± 0.081 mm in vertical plane and 0.211 ± 0.090 mm in the horizontal plane. Compared with 1 month after surgery, the angle of tilt decreased by a mean of 0.192° and decentration increased by a mean of 0.014 mm at the vertical meridian at 2 years postoperatively (P = 0.37 and P = 0.27, respectively), meanwhile, tilt increased by 0.265° and decentration increased by 0.012 mm at the horizontal meridian (P = 0.11 and P = 0.22, respectively). CONCLUSIONS: The follow-up results suggest the tilt and decentration of multifocal IOL implantation with optic capture in Berger space remain stable in an acceptable range within 2 years after cataract surgery in children above the age of 5. TRIAL REGISTRATION: The study was approved by the Ethics Committee of Qingdao Eye Hospital, and registered on Chinese Clinical Trial Registry (ChiCTR identifier: 1900023155).


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares Multifocais , Acuidade Visual , Humanos , Masculino , Feminino , Estudos Prospectivos , Catarata/complicações , Catarata/fisiopatologia , Pré-Escolar , Criança , Extração de Catarata/métodos , Extração de Catarata/efeitos adversos , Seguimentos , Desenho de Prótese , Migração do Implante de Lente Intraocular/diagnóstico , Migração do Implante de Lente Intraocular/fisiopatologia , Migração do Implante de Lente Intraocular/etiologia , Migração do Implante de Lente Intraocular/cirurgia , Implante de Lente Intraocular/métodos , Lactente
3.
Ophthalmic Res ; 67(1): 221-231, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38493781

RESUMO

INTRODUCTION: The aim of this study was to investigate the efficacy of new monofocal intraocular lens (IOL) in comparison with conventional monofocal IOL in patients undergoing combined cataract and vitrectomy surgery for epiretinal membrane (ERM). METHODS: This prospective non-randomized comparative study included 65 eyes of 65 patients who underwent combined cataract and vitrectomy for ERM with implantation of advanced monofocal IOL (Eyhance ICB00, 33 patients) and standard monofocal IOL (Tecnis ZCB00, 32 patients). Monocular visual acuities were measured 6 months post-operatively, including corrected and uncorrected distance visual acuity (CDVA, UCDVA), uncorrected intermediate visual acuity (UCIVA), and uncorrected near visual acuity (UCNVA). Furthermore, contrast sensitivity and metamorphopsia were measured. RESULTS: There was no significant difference between two groups regarding operation time, post-operative CDVA, UCDVA, UCNVA, and spherical equivalent (p > 0.05). Monocular UCIVA was significantly higher in the Eyhance IOL group than in the Tecnis IOL group (p = 0.005). The photopic and mesopic contrast sensitivities were comparable between each group for any spatial frequency (p > 0.05). The correlation coefficients from correlations between retinal wrinkling ratio and M score did not differ significantly between groups (p = 0.877), and the degree of metamorphopsia was not significantly related to the type of IOL (p = 0.969). CONCLUSIONS: In combined cataract and vitrectomy for ERM, Eyhance IOL provided significant better visual performance at intermediate distance than standard monofocal IOL without compromising operation time, distance vision, contrast sensitivity, and evaluating metamorphopsia. Eyhance IOL can be a useful option for both surgeons and patients.


Assuntos
Catarata , Membrana Epirretiniana , Implante de Lente Intraocular , Lentes Intraoculares , Acuidade Visual , Vitrectomia , Humanos , Vitrectomia/métodos , Feminino , Masculino , Acuidade Visual/fisiologia , Estudos Prospectivos , Membrana Epirretiniana/cirurgia , Membrana Epirretiniana/fisiopatologia , Membrana Epirretiniana/diagnóstico , Idoso , Pessoa de Meia-Idade , Catarata/fisiopatologia , Catarata/complicações , Implante de Lente Intraocular/métodos , Sensibilidades de Contraste/fisiologia , Desenho de Prótese , Seguimentos , Resultado do Tratamento , Facoemulsificação/métodos
4.
Am J Ophthalmol ; 262: 34-39, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38311153

RESUMO

PURPOSE: To report visual acuity (VA) outcomes, intraoperative and postoperative complications of isolated cataract surgery in eyes with retinitis pigmentosa (RP), compared with non-RP-affected eyes. DESIGN: Retrospective clinical cohort study. METHODS: A total of 113,389 eyes underwent cataract surgery between July 2003 and March 2015 at 8 clinical sites in the United Kingdom. Eyes with RP as the only comorbid pathology and eyes without any ocular comorbidities (controls) undergoing cataract surgery were compared. VA at 4 to 12 weeks postoperatively and rates of intraoperative and postoperative complications are reported. RESULTS: Seventy-two eyes had RP. The mean age in the RP group was 57 ± 15 compared to 75 ± 10 in controls (P < .001). Females represented 46% of RP cases and 60% of controls (P = .06). Preoperative VA (mean LogMAR = 1.03 vs 0.59, P < .001) and postoperative VA (0.71 vs 0.14, P < .001) were worse in RP group. The mean VA gain was 0.25 ± 0.60 LogMAR in RP vs 0.43 ± 0.48 LogMAR in controls (P < .001). There were no significant differences in the rate of intraoperative pupil expansion use, posterior capsular tears, or zonular dialysis. Postoperative cystoid macular edema developed in 6.9% of RP eyes and 1% of controls (P < .001). The need for IOL repositioning or exchange was not statistically different between the two groups. CONCLUSION: Cataract surgery can improve vision in eyes with RP and cataract. Intraoperative complications were similar to control eyes; however, RP eyes experienced more frequent postoperative cystoid macular edema.


Assuntos
Complicações Intraoperatórias , Implante de Lente Intraocular , Complicações Pós-Operatórias , Retinose Pigmentar , Acuidade Visual , Humanos , Retinose Pigmentar/fisiopatologia , Retinose Pigmentar/complicações , Retinose Pigmentar/cirurgia , Feminino , Acuidade Visual/fisiologia , Masculino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Bases de Dados Factuais , Adulto , Resultado do Tratamento , Extração de Catarata , Catarata/complicações , Catarata/fisiopatologia , Idoso de 80 Anos ou mais , Facoemulsificação , Reino Unido/epidemiologia
5.
Acta Ophthalmol ; 102(4): e602-e611, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38146059

RESUMO

OBJECTIVES: To examine the impact of cataract surgery on mild cognitive impairment (MCI) and dementia in older people. METHODS: This prospective observational study included patients aged 75 years and older who underwent cataract surgery between 2019 and 2021. Mini-mental state examination (MMSE) and MMSE for the visually impaired (MMSE-blind) were measured to evaluate cognitive function before and 3 months after cataract surgery. MMSE score at baseline was used to categorize patients into dementia (MMSE ≤ 23) and MCI groups (23 < MMSE ≤ 27). Logistic regression models were used to estimate associations between improvement in cognitive function and other factors. RESULTS: Of 132 patients screened for inclusion in the study, 88 met the inclusion criteria; 39 patients were assigned to the dementia group (mean age, 85.7 ± 4.2 years) and 49 to the MCI group (mean age, 84.2 ± 3.4 years). The MCI group showed significant improvement from before to after surgery in the MMSE score (25.65 ± 1.03 vs. 27.08 ± 1.99, respectively, p < 0.001) and MMSE-blind score (18.04 ± 1.14 vs. 19.41 ± 2.01, respectively, p < 0.001). Cognitive function improved significantly in the MCI group compared with the dementia group (odds ratio, 2.85; 95% confidence interval, 1.02-7.97; and p = 0.046). CONCLUSIONS: Cataract surgery significantly increases cognitive test scores in older patients with MCI. After cataract surgery, the likelihood of improvement in cognitive function may be highly dependent on a patient's preoperative cognitive state.


Assuntos
Extração de Catarata , Disfunção Cognitiva , Humanos , Masculino , Feminino , Estudos Prospectivos , Idoso de 80 Anos ou mais , Disfunção Cognitiva/diagnóstico , Disfunção Cognitiva/etiologia , Disfunção Cognitiva/fisiopatologia , Idoso , Seguimentos , Cognição/fisiologia , Catarata/complicações , Catarata/psicologia , Catarata/fisiopatologia , Acuidade Visual/fisiologia
7.
Mol Med Rep ; 25(1)2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34751414

RESUMO

According to emerging evidence, long non­coding RNAs (lncRNAs) play critical roles in diabetes. The aim of the present study was to investigate the role and mechanism of X­inactive specific transcript (XIST) in cell proliferation, migration and apoptosis in diabetic cataracts (DC). SRA01/04 lens epithelial cells were treated with high glucose (HG). The levels of XIST, microRNA (miR)­34a and SMAD family member 2 (SMAD2) were examined via reverse transcription­quantitative PCR. MTT, Transwell, wound healing and TUNEL assays were performed to examine cell proliferation, invasion, migration and apoptosis, respectively. The interaction between miR­34a and XIST or SMAD2 was verified by luciferase reporter assay. It was found that the expression of XIST was increased and that of miR­34a was decreased in DC tissues and HG­treated SRA01/04 cells. XIST knockdown or miR­34a overexpression attenuated cell proliferation and migration, and induced apoptosis in HG­treated SRA01/04 cells. XIST targeted miR­34a and regulated DC progression through miR­34a. SMAD2 was identified as a target gene of miR­34a and was positively modulated by XIST. XIST knockdown inhibited cell proliferation and migration, and accelerated apoptosis in HG­stimulated SRA01/04 cells, and these effects were abrogated by SMAD2 overexpression. In conclusion, XIST promoted cell proliferation, migration and invasion, and inhibited apoptosis, through the miR­34a/SMAD2 axis in DC.


Assuntos
Catarata/genética , MicroRNAs/metabolismo , RNA Longo não Codificante/metabolismo , Proteína Smad2/metabolismo , Apoptose/genética , Catarata/metabolismo , Catarata/fisiopatologia , Movimento Celular/genética , Proliferação de Células/genética , China , Complicações do Diabetes/genética , Complicações do Diabetes/metabolismo , Diabetes Mellitus/metabolismo , Células Epiteliais/metabolismo , Feminino , Humanos , Masculino , MicroRNAs/genética , Pessoa de Meia-Idade , RNA Longo não Codificante/genética , Proteína Smad2/genética
8.
Sci Rep ; 11(1): 16141, 2021 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-34373485

RESUMO

To assess the repeatability and comparability of the Galilei G4 versus the Cassini topographer in post-refractive eyes and in normal eyes, including older patients representative of an initial cataract evaluation. Simulated keratometric (simK), total corneal and posterior corneal power and astigmatism were evaluated in both post-refractive and normal eyes. Repeatability was measured by calculating within-subject standard deviation (Sw), coefficient of variation (CoV), and intraclass correlation coefficient (ICC). Vector analyses and Bland-Altman plots were employed to assess agreement between devices. We studied 32 subjects with a history of refractive surgery and 32 subjects without a history of refractive surgery undergoing cataract surgery. The mean age was 55 ± 18.5 years and the age range was 21.5-91.5 years. In non-refractive and post-refractive eyes, the ICC was > 0.9 (P < 0.001) for all corneal powers and for simK and total corneal astigmatism for both analyzers. The ICC for posterior corneal astigmatism magnitude using the Galilei was 0.62 and 0.67 and for the Cassini 0.55 and 0.38 in normal and post-refractive eyes, respectively. In both post-refractive and normal eyes, the Galilei G4 and Cassini analyzers have high repeatability in simK, total, and posterior corneal power and low repeatability for posterior corneal astigmatism.


Assuntos
Astigmatismo/fisiopatologia , Catarata/fisiopatologia , Córnea/fisiopatologia , Topografia da Córnea/métodos , Procedimentos Cirúrgicos Refrativos/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Astigmatismo/diagnóstico , Catarata/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Refração Ocular/fisiologia , Reprodutibilidade dos Testes , Testes Visuais/métodos , Adulto Jovem
9.
Sci Rep ; 11(1): 16107, 2021 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-34373536

RESUMO

This study investigates the etiology and clinical features of delayed vitreous prolapse after cataract surgery and evaluates the long-term surgical and visual outcomes. Consecutive patients with vitreous prolapse into the anterior chamber occurring ≥ 3 months after cataract surgery at two hospitals between December 2006 and June 2020 were retrospectively reviewed. The primary outcome was associated ophthalmological events that triggered delayed vitreous prolapse. Secondary outcomes included long-term visual and subjective symptom changes after treatment. Among 20 eyes (20 patients), all had visual symptoms, the most common being blurry vision (12 patients; 60%). Five (25%) were detected after YAG laser capsulotomy, three (15%) had a history of intraocular lens(IOL) implantation in sulcus due to intraoperative posterior capsular tears, three (15%) had prolapsed vitreous alongside dislocated IOLs, and three (15%) were aphakic after previous cataract surgeries. After surgical treatment, the mean corrected distance visual acuity improved from 20/50 to 20/31(P = 0.02) and the mean preoperative intraocular pressure (IOP) that was 26.4 mmHg decreased to 15.6 mmHg, remaining stable until the last follow-up. All reported symptoms were relieved. YAG laser capsulotomy or a history of defective posterior capsule from iatrogenic causes may trigger delayed vitreous prolapse. The long-term outcomes were favorable, particularly after posterior vitrectomy, with improved IOP control and symptom resolution.


Assuntos
Câmara Anterior/fisiopatologia , Catarata/fisiopatologia , Acuidade Visual/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Câmara Anterior/cirurgia , Opacificação da Cápsula/cirurgia , Extração de Catarata/métodos , Feminino , Humanos , Pressão Intraocular/fisiologia , Cápsula do Cristalino/cirurgia , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/fisiopatologia , Prolapso , Estudos Retrospectivos , Resultado do Tratamento , Transtornos da Visão/fisiopatologia , Transtornos da Visão/cirurgia , Vitrectomia/métodos
10.
Mol Vis ; 27: 384-395, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34220184

RESUMO

Purpose: Ephrin (Eph) receptor A2 (EPHA2) polymorphism has been associated with age-related cataract (ARC) in different populations worldwide, but the mechanisms by which this polymorphism results in the development of ARC are unclear. Here, we chose four EPHA2 single nucleotide polymorphisms (SNPs; rs35903225, rs145592908, rs137853199, and rs116506614) and studied their function in human lens epithelial cells (LECs). Methods: The four EPHA2 mutants were overexpressed using lentiviral transduction in human LECs. Cells expressing wild-type (WT) and mutated EPHA2 were subjected to quantitative PCR (qPCR), western blot, immunoprecipitation (IP), and transwell migration assay. MG132 and chloroquine were used to inhibit the degradation of the WT and mutated EPHA2. The structural changes induced by rs137853199 were predicted and optimized using Schrödinger software. IP-mass spectrometry (IP-MS) was performed to examine the proteins that directly interact with WT and rs137853199 EPHA2. Sanger sequencing was performed to determine the frequency of rs137853199 in 184 patients with ARC (73 cortical cataracts, 56 nuclear cataracts, and 55 posterior subcapsular cataracts) and 49 normal controls. Results: Compared with the WT and the other three mutations, the rs137853199 mutation specifically resulted in a significant decrease in the expression of EPHA2. We identified that EPHA2 rs137853199 is degraded via the ubiquitin-proteasomal pathway through a lysine-48 (K48) residue linkage. Furthermore, the knockdown of EPHA2 reduced cell migration; while the overexpression of WT EPHA2 rescued this defect, the overexpression of rs137853199 EPHA2 did not. In addition, in cells overexpressing rs137853199 EPHA2, the expression of ß-catenin, a key protein that regulates cell migration, significantly decreased. We predicted that rs137853199 would induce a conformational change at a linker position in the carboxyl terminal of EPHA2. The IP-MS results showed that the main molecular functions of the proteins that specifically bind WT or rs137853199 EPHA2 are binding and catalysis, while the main protein class is the protein-modifying enzyme. Finally, we discovered that the minor allele frequency of rs137853199 was significantly higher in cortical cataract patients than it was in normal controls. Conclusions: In summary, these findings suggest a mechanism by which a point mutation in EPHA2 disrupts protein stability, expedites protein degradation, and decreases cell mobility. Importantly, this mutant is associated with cortical cataracts.


Assuntos
Catarata/genética , Células Epiteliais/metabolismo , Regulação da Expressão Gênica/fisiologia , Cristalino/metabolismo , Polimorfismo de Nucleotídeo Único/genética , Receptor EphA2/genética , Idoso , Idoso de 80 Anos ou mais , Western Blotting , Catarata/fisiopatologia , Feminino , Humanos , Lentivirus/genética , Masculino , Pessoa de Meia-Idade , Mutação Puntual , Reação em Cadeia da Polimerase em Tempo Real , Transfecção
11.
Exp Eye Res ; 210: 108705, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34297945

RESUMO

Crystallins, the most prevalent lens proteins, have no turnover throughout the entire human lifespan. These long-lived proteins are susceptible to post-synthetic modifications, including oxidation and glycation, which are believed to be some of the primary mechanisms for age-related cataractogenesis. Thanks to high glutathione (GSH) and ascorbic acid (ASA) levels as well as low oxygen content, the human lens is able to maintain its transparency for several decades. Aging accumulates substantial changes in the human lens, including a decreased glutathione concentration, increased reactive oxygen species (ROS) formation, impaired antioxidative defense capacity, and increased redox-active metal ions, which induce glucose and ascorbic acid degradation and protein glycation. The glycated lens crystallins are either prone to UVA mediated free radical production or they attract metal ion binding, which can trigger additional protein oxidation and modification. This vicious cycle is expected to be exacerbated with older age or diabetic conditions. ASA serves as an antioxidant in the human lens under reducing conditions to protect the human lens from damage, but ASA converts to the pro-oxidative role and causes lens protein damage by ascorbylation in high oxidation or enriched redox-active metal ion conditions. This review is dedicated in honor of Dr. Frank Giblin, a great friend and superb scientist, whose pioneering and relentless work over the past 45 years has provided critical insight into lens redox regulation and glutathione homeostasis during aging and cataractogenesis.


Assuntos
Envelhecimento/fisiologia , Catarata/metabolismo , Glicosilação , Cristalino/metabolismo , Processamento de Proteína Pós-Traducional/fisiologia , Animais , Ácido Ascórbico/farmacologia , Catarata/fisiopatologia , Cristalinas/metabolismo , Glutationa/metabolismo , Humanos , Cristalino/efeitos dos fármacos , Oxirredução , Ligação Proteica , Espécies Reativas de Oxigênio/metabolismo
12.
Invest Ophthalmol Vis Sci ; 62(7): 23, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-34156426

RESUMO

Purpose: The purpose of this study was to determine the importance of the xCT is a subunit. The cystine/glutamate antiporter is actually system xc-xCT subunit of the cystine/glutamate antiporter in maintaining redox balance by investigating the effects of the loss of xCT on lens transparency and cystine/cysteine balance in the aqueous humour. Methods: C57Bl/6 wild-type and xCT knockout mice at five age groups (6 weeks to 12 months) were used. Lens transparency was examined using a slit-lamp and morphological changes visualized by immunolabelling and confocal microscopy. Quantification of glutathione in lenses and cysteine and cystine levels in the aqueous was conducted by liquid chromatography tandem mass spectrometry (LC-MS/MS). Results: Slit-lamp examinations revealed that 3-month-old wild-type mice and xCT knockout mice lenses exhibited an anterior localized cataract. The frequency of this cataract significantly increased in the knockout mice compared to the wild-type mice. Morphological studies revealed a localized swelling of the lens fiber cells at the anterior pole. Glutathione levels in whole lenses were similar between wild-type and knockout mice. However, glutathione levels were significantly decreased at 3 months in the knockout mice in the lens epithelium compared to the wild-type mice. Aqueous cysteine levels remained similar between wild-type and knockout mice at all age groups, whereas cystine levels were significantly increased in 3-, 9-, and 12-month-old knockout mice compared to wild-type mice. Conclusions: Loss of xCT resulted in the depletion of glutathione in the epithelium and an oxidative shift in the cysteine/cystine ratio of the aqueous. Together, these oxidative changes may contribute to the accelerated development of an anterior cataract in knockout mice, which appears to be a normal feature of aging in wild-type mice.


Assuntos
Envelhecimento/fisiologia , Humor Aquoso , Catarata , Cistina/metabolismo , Ácido Glutâmico/metabolismo , Cristalino , Animais , Antiporters/metabolismo , Humor Aquoso/diagnóstico por imagem , Humor Aquoso/fisiologia , Catarata/diagnóstico , Catarata/metabolismo , Catarata/fisiopatologia , Cristalino/diagnóstico por imagem , Cristalino/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Microscopia Confocal/métodos , Oxirredução , Estresse Oxidativo , Microscopia com Lâmpada de Fenda/métodos
13.
Sci Rep ; 11(1): 12869, 2021 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-34145357

RESUMO

This study evaluated the accuracy of total keratometry (TK) and standard keratometry (K) for intraocular lens (IOL) power calculation in eyes treated with femtosecond laser-assisted cataract surgery. The retrospective study included a retrospective analysis of data from 62 patients (91 eyes) who underwent uneventful femtosecond laser-assisted cataract surgery with Artis PL E (Cristalens Industrie, Lannion, France) IOL implantation by a single surgeon between May 2020 and December 2020 in Severance Hospital, Seoul, South Korea. The new IOLMaster 700 biometry device (Carl Zeiss Meditec, Jena, Germany) was used to calculate TK and K. The mean absolute error (MAE), median absolute error (MedAE), and the percentages of eyes within prediction errors of ± 0.25 D, ± 0.50 D, and ± 1.00 D were calculated for all IOL formulas (SRK/T, Hoffer-Q, Haigis, Holladay 1, Holladay 2, and Barrett Universal II). There was strong agreement between K and TK (intraclass correlation coefficient = 0.99), with a mean difference of 0.04 D. For all formulas, MAE tended to be lower for TK than for K, and relatively lower MAE and MedAE values were observed for SRK/T and Holladay 1. Furthermore, for all formulas, a greater proportion of eyes fell within ± 0.25 D of the predicted postoperative spherical equivalent range in the TK group than in the K group. However, differences in MAEs, MedAEs, and percentages of eyes within the above prediction errors were not statistically significant. In conclusion, TK and K exhibit comparable performance for refractive prediction in eyes undergoing femtosecond laser-assisted cataract surgery.


Assuntos
Biometria , Extração de Catarata/métodos , Extração de Catarata/normas , Catarata/terapia , Cristalino/cirurgia , Lentes Intraoculares , Refração Ocular , Idoso , Idoso de 80 Anos ou mais , Catarata/fisiopatologia , Feminino , Humanos , Cristalino/fisiopatologia , Lentes Intraoculares/normas , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
14.
Acta Ophthalmol ; 99(7): e1013-e1017, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34080310

RESUMO

AIMS: To determine brake reaction times before and after bilateral cataract surgery in elderly drivers. METHODS: Sixty-four patients were evaluated on the day of and 4 weeks after bilateral cataract surgery. Forty-three healthy individuals with a valid driving licence served as the control group. A driving simulator was used to determine brake reaction times after receiving a visual stimulus. Total brake reaction time (BRT) as well as neurologic reaction time (NRT), foot transfer time (FTT) and brake pedal travel time (BPTT) were measured, and the measurements obtained before and after cataract surgery were compared. The correlations between NRT, best-corrected visual acuity (BCVA) and contrast sensitivity (CS) were assessed. RESULTS: Out of the 64 patients with bilateral cataract, 53 were assessed for postsurgical measurements. All time measures improved significantly after cataract surgery (BRT, 815.7(224) versus 647.9(148) ms; NRT, 364.7(91) versus 283.5(44) ms; FTT, 290.8(62) versus 248.6(58) ms; and BPTT, 160.6(96) versus 116.6(72) ms, p < 0.001). The calculated stopping distance improved significantly after surgery (22.3(6) versus 19.9(4) m at 50 km/h). Best-corrected visual acuity (BCVA) and contrast sensitivity (CS) improved significantly after surgery (0.25(0.2) versus 0.05(0.05), n = 53, p < 0.001; 1.4(0.2) versus 1.6(0.1), p < 0.001, respectively). There was a significant negative correlation between CS and NRT before surgery (r = -0.253, n = 64, p = 0.04, Pearson's correlation). CONCLUSION: Our findings show a significant effect of CS on neurological BRTs and the corresponding stopping distances. This highlights the importance of presurgical CS evaluation as a critical factor in cataract surgery decisions in elderly drivers.


Assuntos
Condução de Veículo/psicologia , Extração de Catarata , Catarata/psicologia , Sensibilidades de Contraste/fisiologia , Tempo de Reação/fisiologia , Idoso , Catarata/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
15.
PLoS One ; 16(6): e0252787, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34138900

RESUMO

Suboptimal cataract surgery outcomes remain a challenge in most developing countries. In Ghana, about 2 million people have been reported to be blind due to cataract with about 20% new cases being recorded yearly. The aim of this study was to evaluate postoperative correction of refractive errors after cataract surgery in a selected eye hospital in Ashanti Region, Ghana. This was a retrospective study where medical records of patients (aged 40-100) who reported to an eye hospital in Ghana from 2013-2018 were reviewed. Included in the study were patients aged ≥40 years and patients with complete records. Data on patient demographics, type of surgery, intra-ocular lens (PCIOL) power, availability of biometry, postoperative refraction outcomes, pre- and postoperative visual acuity were analyzed. Data of two hundred and thirteen eyes of 190 patients who met the inclusion criteria were analyzed. Descriptive analysis and Chi-square test were carried out to determine the mean, median, standard deviation and relevant associations. The mean ± SD age was 67.21±12.2 years (51.2% were females). Small Incision Cataract Surgery (99.5%) with 100% IOL implants was the main cataract surgery procedure in this study. Pre-operative biometry was performed for 38.9% of all patients on their first eye surgery and 41.5% for second eye surgeries. About 71% eyes in this study were blind (presenting VA<3/60) before surgery; 40.4% had post-operative VA <3/60. Pre-existing ocular comorbidities discovered post- surgery, attributed to suboptimal visual outcomes. More than half (55.3%) of patients did not undergo postoperative refraction due to loss to follow-up. Year of surgery (p = .017), follow up visits< 2months (p < .0001) and discovered comorbidity post-surgery (p = .035) were the factors significantly associated with postoperative refraction. Myopia and compound myopic astigmatism were the dominant refractive error outcomes. The timing of post-operative refraction had a significant effect on postoperative refraction done. These findings indicate a clinically meaningful significance between completion of postoperative care and postoperative refraction done. Consequently, with settings in most developing countries, where less biometry is done, it is appropriate that post-operative refractive services are encouraged and done earlier to enhance the patients' expectations while increasing cataract surgery patronage.


Assuntos
Extração de Catarata/métodos , Catarata/prevenção & controle , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Erros de Refração/prevenção & controle , Procedimentos Cirúrgicos Refrativos/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Catarata/fisiopatologia , Feminino , Gana , Humanos , Implante de Lente Intraocular/métodos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde/métodos , Período Pós-Operatório , Refração Ocular/fisiologia , Erros de Refração/fisiopatologia , Estudos Retrospectivos , Acuidade Visual/fisiologia
16.
PLoS One ; 16(6): e0253210, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34170915

RESUMO

BACKGROUND/AIMS: Determine the association between physician-deemed and patient-reported appropriateness and prioritization for cataract surgery. METHODS: Prospective cohort study of 471 patients of 7 ophthalmologists referred for cataract surgery. Ophthalmologists rated patients for cataract surgery appropriateness and prioritization using a visual analogue scale of 0-10 preoperatively. All patients completed the eCAPS Quality of Life (QoL), while 313 completed the Catquest-9SF and EQ-5D questionnaires. Regression analyses were applied to determine demographic, clinical and patient-reported outcome measures (PROMs) associated with appropriateness and prioritization. RESULTS: Two clinical factors (study eye and fellow eye best-corrected visual acuity (BCVA)), 2 eCAPS (night driving difficulty, ability to take care of local errands), and 2 Catquest-9SF PROMs (recognizing faces, seeing to walk on uneven ground) were associated with appropriateness. In multivariable regression, the rating physician, 2 clinical criteria (study eye BCVA, anticipated postoperative BCVA) and 1 eCAPS QoL (night driving difficulty) were associated with appropriateness. Prioritization was associated with low income, 8 clinical criteria, 9 eCAPS, 5 Catquest-9SF, and 1 EQ-5D PROMs. In multivariable regression, 1 clinical criterion (study eye BCVA), 2 eCAPS QoL (night driving difficulty, ability to take care of local errands), and 2 Catquest-9SF PROMs (seeing prices, seeing to walk on uneven ground) were significantly associated. CONCLUSIONS: The eCAPS and Catquest-9SF questionnaires show some concordance with physician-deemed appropriateness, and more with prioritization. Binary conversions of PROM scales provide similar modelling, with minimal loss of explanatory power. As physician-deemed appropriateness and prioritization do not completely capture the patient perspective, PROMs may have a role in cataract surgery decision-making frameworks.


Assuntos
Extração de Catarata , Catarata/fisiopatologia , Medidas de Resultados Relatados pelo Paciente , Médicos , Qualidade de Vida , Inquéritos e Questionários , Acuidade Visual , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
17.
Sci Rep ; 11(1): 12203, 2021 06 09.
Artigo em Inglês | MEDLINE | ID: mdl-34108591

RESUMO

The purpose of this study was to evaluate intraocular pressure (IOP) pre- and postoperatively, together with anterior chamber angle (ACA) parameters and biometrical results in cataract patients with or without open angle glaucoma (OAG). The prospective observational case-control study included 15 eyes with cataract and OAG in the glaucoma group and 25 eyes with only cataract in control group. Examination included full ophthalmic evaluation, IOP, ocular biometry and anterior segment optical coherence tomography measuring ACA pre- and 6 months postoperatively. OAG patients had a larger absolute IOP reduction compared to control group. Anterior chamber depth (ACD) and ACA width significantly increased in both groups. The OAG group had a tendency of narrower ACA preoperatively, but overall ACA parameters did not differ in either group pre- and postoperatively. The ACD change after surgery correlated with ACA parameters in the control group, but not in OAG group. Axial length was shorter postoperatively in the control group, but remained similar in the OAG group. Absolute IOP reduction was more pronounced in cataract patients with OAG than in cataract patients without glaucoma. ACD and ACA postoperatively increased in both groups and AL shortening was observed in non-OAG in cataract group.


Assuntos
Catarata/fisiopatologia , Glaucoma de Ângulo Aberto/fisiopatologia , Pressão Intraocular/fisiologia , Tonometria Ocular/métodos , Idoso , Biometria , Estudos de Casos e Controles , Catarata/complicações , Catarata/terapia , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/complicações , Glaucoma de Ângulo Aberto/cirurgia , Humanos , Masculino , Facoemulsificação , Prognóstico , Estudos Prospectivos , Tomografia de Coerência Óptica
18.
PLoS One ; 16(5): e0251152, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33945581

RESUMO

PURPOSE: To compare the biometry and prediction of postoperative refractive outcomes of four different formulae (Haigis, SRK/T, Holladay1, Barrett Universal II) obtained by swept-source optical coherence tomography (SS-OCT) biometers and partial coherence interferometry (PCI; IOLMaster ver 5.4). METHODS: We compared the biometric values of SS-OCT (ANTERION, Heidelberg Engineering Inc., Heidelberg, Germany) and PCI (IOLMaster, Carl Zeiss Meditec, Jena, Germany). Predictive errors calculated using four different formulae (Haigis, SRKT, Holladay1, Barrett Universal II) were compared at 1 month after cataract surgery. RESULTS: The mean preoperative axial length (AL) showed no statistically significant difference between SS-OCT and PCI (SS-OCT: 23.78 ± 0.12 mm and PCI: 23.77 ± 0.12 mm). The mean anterior chamber depth (ACD) was 3.30 ± 0.04 mm for SS-OCT and 3.23 ± 0.04 mm for PCI, which was significantly different between the two techniques. The mean corneal curvature also differed significantly between the two techniques. The difference in mean arithmetic prediction error was significant in the Haigis, SRKT, and Holladay1 formulae. The difference in mean absolute prediction error was significant in all four formulae. CONCLUSIONS: SS-OCT and PCI demonstrated good agreement on biometric measurements; however, there were significant differences in some biometric values. These differences in some ocular biometrics can cause a difference in refractive error after cataract surgery. New type SS-OCT was not superior to the IOL power prediction calculated by PCI.


Assuntos
Interferometria/métodos , Intervenção Coronária Percutânea/métodos , Erros de Refração/fisiopatologia , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Comprimento Axial do Olho/cirurgia , Biometria/métodos , Catarata/fisiopatologia , Extração de Catarata/métodos , Córnea/fisiopatologia , Córnea/cirurgia , Olho Artificial , Feminino , Alemanha , Humanos , Lentes Intraoculares , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Testes Visuais
19.
Am J Ophthalmol ; 227: 201-210, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33626362

RESUMO

PURPOSE: To characterize and compare patient-reported recovery of function after cataract or glaucoma surgery using a novel visual analog scale. DESIGN: Prospective observational cohort study. METHODS: Daily for 2 weeks and weekly thereafter, patients recovering from trabeculectomy, tube shunt implantation, or cataract extraction (CE) completed a diary-style questionnaire including visual analog scales (VASs; scored 0-100) grading pain and global function. Clinical examination data and medical histories were collected. Generalized estimating equation models evaluated associations between VAS function scores and pain or visual acuity (VA) and compared scores between surgery types. RESULTS: Among 51 participants followed for 12 weeks, tube shunt placement reduced postoperative day 1 (POD1) function by 47 of 100 points vs CE (P = .006), while trabeculectomy did not reduce POD1 function vs CE (P = .33). After CE, trabeculectomy, and tube shunt placement, average VAS function scores increased 13.94 per week for 2 weeks (P < .001), 4.18 per week for 4 weeks (P = .02), and 7.76 per week for 7 weeks (P < .001), respectively. After those timepoints, there was no further significant change. Beyond 2 weeks, pain levels plateaued, and VA returned to baseline across surgery types; function was inversely related to pain or VA only for the first 2 or 4 weeks, respectively. CONCLUSIONS: Patients recovering from cataract and glaucoma surgery report reduced function in the postoperative period. Tube shunt implantation causes greater morbidity than trabeculectomy, and both are associated with slower improvement than CE. Early postoperative function is associated with VA and pain, but neither fully explains reported impairment. A VAS for function may efficiently capture postoperative recovery.


Assuntos
Implantes para Drenagem de Glaucoma , Pressão Intraocular/fisiologia , Facoemulsificação , Recuperação de Função Fisiológica/fisiologia , Trabeculectomia , Acuidade Visual/fisiologia , Campos Visuais/fisiologia , Idoso , Idoso de 80 Anos ou mais , Catarata/fisiopatologia , Feminino , Glaucoma/fisiopatologia , Humanos , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Estudos Prospectivos , Inquéritos e Questionários , Escala Visual Analógica
20.
PLoS One ; 16(2): e0246816, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33566866

RESUMO

PURPOSE: The aim of this study was to assess the impact of cataract progression using the Haigis formula-calculated intraocular lens (IOL) power and investigate the accuracy of IOL power measured at different time points. METHODS: This prospective study was performed on 75 eyes of 75 patients who underwent uneventful cataract surgery. Preoperative ocular parameters including axial length (AL), keratometry (K), anterior chamber depth (ACD), corneal astigmatism, corrected distance visual acuity (CDVA) and uncorrected distance visual acuity (UDVA) examined at the two time points, more than 3 months preoperatively and preoperative 1 day were compared. The ocular parameters measured in the two time points were used to calculate the predicted implanted IOL power and the actual IOL power was chosen on the basis of parameters measured earlier before surgery using the Haigis formula. The mean numerical error (MNE) and mean absolute error (MAE) predicted by the two time points were also compared. RESULTS: There were significant differences in the ACD, IOL power, UDVA and CDVA (P<0.01), but no statistical differences in AL, mean K and corneal astigmatism (P>0.05) during the average of 5.6 months before surgery. No statistically significant difference was detected in MNE (P>0.05), while the MAE had a significant difference in the two time points (P<0.05). CONCLUSION: The IOL power measured earlier before surgery might result in a higher accuracy and the postoperative refractive outcome tended towards emmetropia.


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares , Acuidade Visual , Idoso , Catarata/patologia , Catarata/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA