Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 798
Filtrar
1.
J Clin Monit Comput ; 38(1): 139-146, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37458916

RESUMO

PURPOSE: Pulse Decomposition Analysis (PDA) uses integration of the systolic area of a distally transmitted aortic pulse as well as arterial stiffness estimates to compute cardiac output. We sought to assess agreement of cardiac output (CO) estimation between continuous pulmonary artery catheter (PAC) guided thermodilution (CO-CCO) and a wireless, wearable noninvasive device, (Vitalstream, Caretaker Medical, Charlottesville, VA), that utilizes the Pulse Decomposition Analysis (CO-PDA) method in postoperative cardiac surgery patients in the intensive care unit. METHODS: CO-CCO measurements were compared with post processed CO-PDA measurements in prospectively enrolled adult cardiac surgical intensive care unit patients. Uncalibrated CO-PDA values were compared for accuracy with CO-CCO via a Bland-Altman analysis considering repeated measurements and a concordance analysis with a 10% exclusion zone. RESULTS: 259.7 h of monitoring data from 41 patients matching 15,583 data points were analyzed. Mean CO-CCO was 5.55 L/min, while mean values for the CO-PDA were 5.73 L/min (mean of differences +- SD 0.79 ± 1.11 L/min; limits of agreement - 1.43 to 3.01 L/min), with a percentage error of 37.5%. CO-CCO correlation with CO-PDA was moderate (0.54) and concordance was 0.83. CONCLUSION: Compared with the CO-CCO Swan-Ganz, cardiac output measurements obtained using the CO-PDA were not interchangeable when using a 30% threshold. These preliminary results were within the 45% limits for minimally invasive devices, and pending further robust trials, the CO-PDA offers a noninvasive, wireless solution to complement and extend hemodynamic monitoring within and outside the ICU.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Artéria Pulmonar , Adulto , Humanos , Termodiluição/métodos , Débito Cardíaco , Cateterismo de Swan-Ganz , Procedimentos Cirúrgicos Cardíacos/métodos , Cuidados Críticos , Unidades de Terapia Intensiva , Reprodutibilidade dos Testes
2.
Artigo em Inglês | MEDLINE | ID: mdl-38082621

RESUMO

Providing imaging during interventional treatments of cardiovascular diseases is challenging. Magnetic Resonance Imaging (MRI) has gained popularity as it is radiation-free and returns high resolution of soft tissue. However, the clinician has limited access to the patient, e.g., to their femoral artery, within the MRI scanner to accurately guide and manipulate an MR-compatible catheter. At the same time, communication will need to be maintained with a clinician, located in a separate control room, to provide the most appropriate image to the screen inside the MRI room. Hence, there is scope to explore the feasibility of how autonomous catheterization robots could support the steering of catheters along trajectories inside complex vessel anatomies.In this paper, we present a Learning from Demonstration based Gaussian Mixture Model for a robot trajectory optimisation during pulmonary artery catheterization. The optimisation algorithm is integrated into a 2 Degree-of-Freedom MR-compatible interventional robot allowing for continuous and simultaneous translation and rotation. Our methodology achieves autonomous navigation of the catheter tip from the inferior vena cava, through the right atrium and the right ventricle into the pulmonary artery where an interventions is performed. Our results show that our MR-compatible robot can follow an advancement trajectory generated by our Learning from Demonstration algorithm. Looking at the overall duration of the intervention, it can be concluded that procedures performed by the robot (teleoperated or autonomously) required significantly less time compared to manual hand-held procedures.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Robótica/métodos , Cateterismo de Swan-Ganz , Catéteres , Cateterismo
3.
Crit Care ; 27(1): 412, 2023 10 28.
Artigo em Inglês | MEDLINE | ID: mdl-37898794

RESUMO

BACKGROUND: It has been 50 years since the pulmonary artery catheter was introduced, but the actual use of pulmonary artery catheters in recent years is unknown. Some randomized controlled trials have reported no causality with mortality, but some observational studies have been published showing an association with mortality for patients with cardiogenic shock, and the association with a pulmonary artery catheter and mortality is unknown. The aim of this study was to investigate the utilization of pulmonary artery catheters (PACs) in the intensive care unit (ICU) and to examine their association with mortality, taking into account differences between hospitals. METHODS: This is a retrospective analysis using the Japanese Intensive care PAtient Database, a multicenter, prospective, observational registry in Japanese ICUs. We included patients aged 16 years or older who were admitted to the ICU for reasons other than procedures. We excluded patients who were discharged within 24 h or had missing values. We compared the prognosis of patients with and without PAC. The primary outcome was hospital mortality. We performed propensity score analysis to adjust for baseline characteristics and hospital characteristics. RESULTS: Among 184,705 patients in this registry from April 2015 to December 2020, 59,922 patients were included in the analysis. Most patients (94.0%) with a PAC in place had cardiovascular disease. There was a wide variation in the frequency of PAC use between hospitals, from 0 to 60.3% (median 14.4%, interquartile range 2.2-28.6%). Hospital mortality was not significantly different between the PAC use group and the non-PAC use group in patients after adjustment for propensity score analysis (3.9% vs 4.3%; difference, - 0.4%; 95% CI - 1.1 to 0.3; p = 0.32). Among patients with cardiac disease, those with post-open-heart surgery and those in shock, hospital mortality was also not significantly different between the two groups (3.4% vs 3.7%, p = 0.45, 1.7% vs 1.7%, p = 0.93, 4.8% vs 4.9%, p = 0.87). CONCLUSIONS: The frequency of PAC use varied among hospitals. PAC use for ICU patients was not associated with lower hospital mortality after adjusting for differences between hospitals.


Assuntos
Cateterismo de Swan-Ganz , Artéria Pulmonar , Humanos , Catéteres , Cuidados Críticos , População do Leste Asiático , Mortalidade Hospitalar , Unidades de Terapia Intensiva , Japão/epidemiologia , Estudos Prospectivos , Estudos Retrospectivos
5.
Curr Opin Crit Care ; 29(3): 231-235, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37078636

RESUMO

PURPOSE OF REVIEW: To review recently published data on pulmonary artery catheter (PAC) use in critically ill patients and consider optimal use of the PAC in personalized clinical practice. RECENT FINDINGS: Although PAC use has decreased considerably since the mid-1990s, PAC-derived variables can still have an important role in elucidating hemodynamic status and directing management in complex patients. Recent studies have suggested benefit, notably in patients having cardiac surgery. SUMMARY: Only a small number of acutely ill patients require a PAC and insertion should be individualized based on clinical context, availability of trained staff, and the possibility that measured variables will be able to help guide therapy.


Assuntos
Cateterismo de Swan-Ganz , Artéria Pulmonar , Humanos , Artéria Pulmonar/cirurgia , Cuidados Críticos , Hemodinâmica , Catéteres
6.
J Cardiothorac Vasc Anesth ; 37(8): 1377-1381, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37121841

RESUMO

OBJECTIVES: The decision algorithm for managing patients in cardiogenic shock depends on cardiac index (CI) estimates. Cardiac index estimation via thermodilution (CI-TD) using a pulmonary artery catheter is used commonly for obtaining CI in these patients. Minimally invasive methods of estimating CI, such as multibeat analysis (CI-MBA), may be an alternative in this population. DESIGN: A prospective, observational study. SETTING: Cardiac intensive care unit. PARTICIPANTS: Twenty-two subjects in cardiogenic shock provided 101 paired CI measurements. INTERVENTIONS: Measurements were obtained concomitantly by intermittent CI-TD and CI-MBA (Argos Cardiac Output Monitor; Retia Medical, Valhalla, NY). For each CI-TD, CI-MBA estimates were averaged over 1 minute to provide paired values. Bland-Altman and 4-quadrant analyses were performed by plotting changes between successive CI measurements (ΔCI) from each of the 2 methods. Concordance was calculated as a percentage using ΔCI data points from the 2 methods, outside an exclusion zone of 15%. MEASUREMENTS AND MAIN RESULTS: The correlation coefficient between CI-MBA and CI-TD was 0.78 across patients. Mean CI-TD was 2.19 ± 0.46 L/min/m2 and mean CI-MBA was 2.38 ± 0.59 L/min/m2. The mean difference between CI-MBA and CI-TD (bias ± SD) was 0.20 ± 0.47 L/min/m2, and the limits of agreement were -0.72 to 1.11 L/min/m2. The percentage error was 40.0%. The concordance rate was 94%. A secondary analysis of a subgroup of patients during periods of arrhythmia demonstrated a similar accuracy of performance of CI-MBA. CONCLUSIONS: Cardiac index-MBA is not interchangeable with CI-TD. However, CI-MBA provides reasonable correlation and clinically acceptable trending ability compared with CI-TD. Cardiac output-MBA may be useful in trending changes in CI in patients with cardiogenic shock, especially in those whose pulmonary artery catheterization placement carries a high risk or is unobtainable.


Assuntos
Cateterismo de Swan-Ganz , Choque Cardiogênico , Humanos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/terapia , Reprodutibilidade dos Testes , Débito Cardíaco , Ponte de Artéria Coronária , Termodiluição/métodos
8.
Surgery ; 172(4): 1285-1290, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35953307

RESUMO

BACKGROUND: Many studies demonstrated no improved survival in patients with pulmonary artery catheter placement. However, no consistent conclusions have been drawn regarding the impact of pulmonary artery catheter in critically ill patients with heart disease. This study aimed to investigate the association of early pulmonary artery catheter use with 28-day mortality in that population. METHODS: The Multiparameter Intelligent Monitoring in Intensive Care IV (MIMIC-IV) database, a single-center critical care database, was employed to investigate this issue. This study enrolled a total of 11,887 critically ill patients with cardiac disease with or without pulmonary artery catheter insertion. The primary outcome was 28-day mortality. The multivariate regression was modeled to examine the association between pulmonary artery catheter and outcomes. Additionally, we examined the effect modification by cardiac surgeries. Propensity score matching was conducted to validate our findings. RESULTS: No improvement in 28-day mortality was observed among the pulmonary artery catheter group compared to the non-pulmonary artery catheter group (odds ratio 95% confidence interval: 1.18 [1.00-1.38], P = .049). When stratified by cardiac surgeries, the results were consistent. The patients in the pulmonary artery catheter group had fewer ventilation-free days and vasopressor-free days than those in the nonpulmonary artery catheter group after surgery stratification. In the surgical patients, pulmonary artery catheter insertion was not associated with the occurrence of acute kidney injury, and it was associated with a higher daily fluid input (mean difference 95% confidence interval: 0.13 [0.05-0.20], P = .001). In nonsurgical patients, the pulmonary artery catheter group had a higher risk of acute kidney injury occurrence (odds ratio 95% confidence interval: 1.94 [1.32-2.84], P = .001). CONCLUSION: Early pulmonary artery catheter placement is not associated with survival benefits in critically ill patients with cardiac diseases, either in surgical or nonsurgical patients.


Assuntos
Injúria Renal Aguda , Cardiopatias , Cateterismo de Swan-Ganz , Cuidados Críticos/métodos , Estado Terminal/terapia , Cardiopatias/cirurgia , Humanos
9.
Kyobu Geka ; 75(8): 598-601, 2022 Aug.
Artigo em Japonês | MEDLINE | ID: mdl-35892298

RESUMO

We herein present a case of massive intratracheal hemorrhage due to pulmonary artery catheter (PAC) use during triple valve surgery. A 75-year-old woman underwent biological aortic valve replacement along with mitral and tricuspid valve annuloplasty. Operative procedures were uneventful. Shortly after weaning from cardiopulmonary bypass, massive blood and froth filled the endotracheal tube. As her blood pressure and arterial oxygen saturation dropped, extracorporeal membrane oxygenation(ECMO) support through the right femoral artery and vein was promptly initiated. After the tip of the PAC was identified in the right pulmonary artery by chest Xray, an endobronchial blocker was used to protect the opposite lung. After clinical stability was achieved, she underwent pulmonary artery angiography and subsequent successful transcatheter embolization. Right heart unloading using ECMO and transcatheter embolization might have played key roles in the management of intraoperative pulmonary artery rupture.


Assuntos
Cateterismo de Swan-Ganz , Artéria Pulmonar , Idoso , Cateterismo de Swan-Ganz/efeitos adversos , Catéteres , Feminino , Hemorragia , Humanos , Pulmão , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Ruptura
10.
Ann Card Anaesth ; 25(3): 335-342, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35799563

RESUMO

Background: An ideal CO monitor should be noninvasive, cost effective, reproducible, reliable during various physiological states. Limited literature is available regarding the noninvasive CO monitoring in open chest surgeries. Aim: The aim of this study was to compare the CO measurement by Regional Impedance Cardiography (RIC) and Thermodilution (TD) method in patients undergoing off pump coronary artery bypass graft surgery (OPCAB). Settings and Design: We conducted a prospective observational comparative study of CO measurement by the noninvasive RIC method using the NICaS Hemodynamic Navigator system and the gold standard TD method using pulmonary artery catheter in patients undergoing OPCAB. A total of 150 data pair from the two CO monitoring techniques were taken from 15 patients between 40-70 years at various predefined time intervals of the surgery. Patients and Methods: We have tried to find out the accuracy, precision and cost effectiveness of the newer RIC technique. Mean CO, bias and precision were compared for each pair i.e.TD-CO and RIC-CO as recommended by Bland and Altman. The Sensitivity and specificity of cutoff value to predict change in TD-CO was used to create a Receiver operating characteristic or ROC curve. Results: Mean TD-CO values were around 4.52 ± 1.09 L/min, while mean RIC- CO values were around 4.77± 1.84 L/min. The difference in CO change was found to be statistically not significant (p value 0.667). The bias was small (-0.25). The Bland Altman plot revealed a mean difference of -0.25 litres. The RIC method had a sensitivity of 55.56 % and specificity of 33.33 % in predicting 15% change in CO of TD method and the total diagnostic accuracy was 46.67%. Conclusion: A fair correlation was found between the two techniques. The RIC method may be considered as a promising noninvasive, potentially low cost alternative to the TD technique of hemodynamic measurement.


Assuntos
Cardiografia de Impedância , Ponte de Artéria Coronária sem Circulação Extracorpórea , Débito Cardíaco/fisiologia , Cardiografia de Impedância/métodos , Cateterismo de Swan-Ganz , Humanos , Reprodutibilidade dos Testes , Termodiluição/métodos
11.
J Vasc Surg Venous Lymphat Disord ; 10(2): 287-292, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34352422

RESUMO

OBJECTIVE: Catheter-directed interventions (CDIs) are commonly performed for acute pulmonary embolism (PE). The evolving catheter types and treatment algorithms impact the use and outcomes of these interventions. This study aimed to investigate the changes in CDI practice and their impact on outcomes. METHODS: Patients who underwent CDIs for PE between 2010 and 2019 at a single institution were identified from a prospectively maintained database. A PE team was launched in 2012, and in 2014 was established as an official Pulmonary Embolism Response Team. CDI annual use trends and clinical failures were recorded. Clinical success was defined as physiologic improvement in the absence of major bleeding, perioperative stroke or other procedure-related adverse event, decompensation for submassive or persistent shock for massive PE, the need for surgical thromboembolectomy, or death. Major bleeding was defined as requiring a blood transfusion, a surgical intervention, or suffering from an intracranial hemorrhage. RESULTS: There were 372 patients who underwent a CDI for acute PE during the study period with a mean age of 58.9 ± 15.4 years; there were males 187 (50.3%) and 340 patients has a submassive PE (91.4%). CDI showed a steep increase in the early Pulmonary Embolism Response Team years, peaking in 2016 with a subsequent decrease. Ultrasound-assisted thrombolysis was the predominant CDI technique peaking at 84% of all CDI in 2014. Suction thrombectomy use peaked at 15.2% of CDI in 2019. The mean alteplase dose with catheter thrombolysis techniques decreased from 26.8 ± 12.5 mg in 2013 to 13.9 ± 7.5 mg in 2019 (P < .001). The mean lysis time decreased from 17.2 ± 8.3 hours in 2013 to 11.3 ± 8.2 hours in 2019 (P < .001). Clinical success for the massive and the submassive PE cohorts was 58.1% and 91.2%, respectively; the major bleed rates were 25.0% and 5.3%. There were two major clinical success peaks, one in 2015 mirroring our technical learning curve and one in 2019 mirroring our patient selection learning curve. The clinical success decrease in 2018 was primarily derived from blood transfusions owing to acute blood loss during suction thrombectomy. CONCLUSIONS: CDIs for acute PE have rapidly evolved with high success rates. Multidisciplinary approaches among centers with appropriate expertise are advisable for the safe and successful implementation of catheter interventions.


Assuntos
Cateterismo de Swan-Ganz/tendências , Procedimentos Endovasculares/tendências , Padrões de Prática Médica/tendências , Embolia Pulmonar/terapia , Trombectomia/tendências , Terapia Trombolítica/tendências , Adulto , Idoso , Transfusão de Sangue/tendências , Cateterismo de Swan-Ganz/efeitos adversos , Cateterismo de Swan-Ganz/mortalidade , Bases de Dados Factuais , Embolectomia/tendências , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Hemostasia Cirúrgica/tendências , Humanos , Hemorragias Intracranianas/etiologia , Hemorragias Intracranianas/terapia , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/mortalidade , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Trombectomia/efeitos adversos , Trombectomia/mortalidade , Terapia Trombolítica/efeitos adversos , Terapia Trombolítica/mortalidade , Fatores de Tempo , Resultado do Tratamento
15.
J Thorac Cardiovasc Surg ; 164(6): 1965-1973.e6, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-33642109

RESUMO

OBJECTIVE: Pulmonary artery catheterization provides continuous monitoring of hemodynamic parameters that may aid in the perioperative management of patients undergoing cardiac surgery. However, prior data suggest that pulmonary artery catheterization has limited benefit in intensive care and surgical settings. Thus, this study sought to determine the impact of pulmonary artery catheter insertion on short-term postoperative outcomes in a large, contemporaneous cohort of patients undergoing open cardiac surgery compared with standard central venous pressure monitoring. METHODS: This was an observational study of open cardiac surgeries from 2010 to 2018. Patients with pulmonary artery catheter insertion were identified and matched against patients without pulmonary artery catheter insertion via 1:1 nearest neighbor propensity matching. Multivariable analysis was performed to assess the impact of pulmonary artery catheterization on operative mortality in the overall cohort, as well as recent heart failure, mitral valve disease, and tricuspid insufficiency subgroups. RESULTS: Of the 11,820 patients undergoing (Society of Thoracic Surgeons indexed) coronary or valvular surgery, 4605 (39.0%) had pulmonary artery catheter insertion. Propensity score matching yielded 3519 evenly balanced pairs. Compared with central venous pressure monitoring, pulmonary artery catheter use was not associated with improved operative mortality in the overall cohort or in the recent heart failure, mitral valve disease, or tricuspid insufficiency subgroups. Intensive care unit length of stay was longer (P < .001), and there were more packed red blood cell transfusions in the pulmonary artery catheterization group (P < .001); however, postoperative outcomes were otherwise similar, including stroke, sepsis, and new renal failure (P > .05). CONCLUSIONS: These findings suggest that pulmonary artery catheterization may have limited benefit in cardiac surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Doenças das Valvas Cardíacas , Insuficiência da Valva Tricúspide , Humanos , Cateterismo de Swan-Ganz/efeitos adversos , Artéria Pulmonar/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Catéteres
16.
J Clin Monit Comput ; 36(5): 1279-1287, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-34559326

RESUMO

We evaluated the disposable non-invasive SpotOn™ thermometer relying on the zero-heat-flux technology. We tested the hypothesis that this technology may accurately estimate the core temperature. The primary objective was to compare cutaneous temperature measurements from this device with blood temperatures measured with the pulmonary artery catheter. Secondary objective was to compare measurements from the zero-heat-flux thermometer indirectly with other routinely used thermometers (nasopharyngeal, bladder, rectal). We included 40 patients electively scheduled for either off-pump coronary artery bypass surgery or pulmonary thromboendarterectomy. Temperatures were measured using zero-heat-flux (SpotOn™), pulmonary artery catheter, nasopharyngeal, rectal, and bladder thermometers. Agreement was assessed using the Bland and Altman random effects method for repeated measures data, and Lin's concordance correlation coefficient. Accuracy was estimated (defined as <0.5° difference with the gold standard), with a 95% confidence interval considering the multiple pairs of measurements per patient. 17 850 sets of temperature measurements were analyzed from 40 patients. The mean overall difference between zero-heat-flux and pulmonary artery catheter thermometer was -0.06 °C (95% limits of agreement of ± 0.89 °C). In addition, 14 968 sets of temperature measurements were analyzed from 34 patients with all thermometers in situ. Results from the zero-heat-flux thermometer showed better agreement with the pulmonary artery catheter than the other secondary core thermometers assessed. In conclusion, the SpotOn™ thermometer reliably assessed core temperature during cardiac surgery. It could be considered an alternative for other secondary thermometers in the assessment of core temperature during general anesthesia.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Termômetros , Temperatura Corporal , Procedimentos Cirúrgicos Cardíacos/métodos , Cateterismo de Swan-Ganz , Temperatura Alta , Humanos
17.
BMC Anesthesiol ; 21(1): 189, 2021 07 10.
Artigo em Inglês | MEDLINE | ID: mdl-34246222

RESUMO

BACKGROUND: Cardiac output (CO) is a key measure of adequacy of organ and tissue perfusion, especially in critically ill or complex surgical patients. CO monitoring technology continues to evolve. Recently developed CO monitors rely on unique algorithms based on pulse contour analysis of an arterial blood pressure (ABP) waveform. The objective of this investigation was to compare the accuracy of two monitors using different methods of pulse contour analysis - the Retia Argos device and the Edwards Vigileo-FloTrac device - with pulmonary artery catheter (PAC)-thermodilution as a reference. METHODS: Fifty-eight patients undergoing off-pump coronary artery bypass surgery formed the study cohort. A total of 572 triplets of CO measurements from each device - Argos, Vigileo-FloTrac (third generation), and thermodilution - were available before and after interventions (e.g., vasopressors, fluids, and inotropes). Bland-Altman analysis accounting for repeated measurements per subject and concordance analysis were applied to assess the accuracy of the CO values and intervention-induced CO changes of each pulse contour device against thermodilution. Cluster bootstrapping was employed to statistically compare the root-mean-squared-errors (RMSE = √(µ2 + σ2), where µ and σ are the Bland-Altman bias and precision errors) and concordance rates of the two devices. RESULTS: The RMSE (mean (95% confidence intervals)) for CO values was 1.16 (1.00-1.32) L/min for the Argos device and 1.54 (1.33-1.77) L/min for the Vigileo-FloTrac device; the concordance rate for intervention-induced CO changes was 87 (82-92)% for the Argos device and 72 (65-78)% for the Vigileo-FloTrac device; and the RMSE for the CO changes was 17 (15-19)% for the Argos device and 21 (19-23)% for the Vigileo-FloTrac device (p < 0.0167 for all comparisons). CONCLUSIONS: In comparison with CO measured by the PAC, the Argos device proved to be more accurate than the Vigileo-FloTrac device in CO trending and absolute CO measurement in patients undergoing off-pump coronary artery bypass surgery.


Assuntos
Débito Cardíaco/fisiologia , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Monitorização Intraoperatória/métodos , Termodiluição/métodos , Idoso , Pressão Arterial/fisiologia , Cateterismo de Swan-Ganz/métodos , Estudos de Coortes , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/instrumentação
18.
BMJ Case Rep ; 14(6)2021 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-34158321

RESUMO

We present an uncommon case report of simultaneous pulmonary embolism and aortic saddle embolism. This patient had risk factors for thromboembolic events that included recent surgery for tibia fracture and immobilisation. She underwent emergency bilateral pulmonary artery catheter-directed thrombolysis, followed by bilateral transfemoral embolectomy. The potential benefit of thrombolysis was weighed against the risk of haemorrhage during the surgery after thrombolysis. Treatment guidelines are not well established for such a condition. This case report illustrates our experience and challenges faced in treating this condition.


Assuntos
Embolia Pulmonar , Terapia Trombolítica , Cateterismo de Swan-Ganz , Embolectomia , Feminino , Humanos , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/etiologia , Embolia Pulmonar/cirurgia , Resultado do Tratamento
19.
BMC Anesthesiol ; 21(1): 73, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-34059000

RESUMO

BACKGROUND: Pulmonary artery catheter insertion is a routine practice in high-risk patients undergoing cardiac surgery. However, pulmonary artery catheter insertion is associated with numerous complications that can be devastating to the patient. Incorrect placement is an overlooked complication with few case reports to date. CASE PRESENTATION: An 18-year-old male patient underwent elective mitral valve replacement due to severe mitral valve regurgitation. The patient had a history of synovial sarcoma, and Hickman catheter had been inserted in the right internal jugular vein for systemic chemotherapy. We made multiple attempts to position the pulmonary artery catheter in the correct position but failed. A chest radiography revealed that the pulmonary artery catheter was bent and pointed in the cephalad direction. Removal of the pulmonary artery catheter was successful, and the patient was discharged 10 days after the surgery without complications. CONCLUSIONS: To prevent misplacement of the PAC, clinicians should be aware of multiple risk factors in difficult PAC placement, and be prepared to utilize adjunctive methods, such as TEE and fluoroscopy.


Assuntos
Cateterismo de Swan-Ganz/efeitos adversos , Cateterismo de Swan-Ganz/métodos , Dispositivos de Acesso Vascular , Adolescente , Cateterismo de Swan-Ganz/instrumentação , Humanos , Masculino , Artéria Pulmonar/diagnóstico por imagem , Radiografia/métodos
20.
Ann Card Anaesth ; 24(1): 4-7, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33938823

RESUMO

Ever since its clinical introduction, the utilization of the pulmonary artery catheter (PAC) has been surrounded by multiple controversies, mostly related to imprecise clinical indications and the complications derived from its placement. Currently, one of the most important criticisms of the PAC is the ambiguity in the interpretation of its hemodynamic measurements and therefore, in the translation of this data into specific therapeutic interventions. The popularity of the PAC stems from the fact that it provides hemodynamic data that cannot be obtained from clinical examination. The assumption is that this information would allow better understanding of the individual's hemodynamic profile which would trigger therapeutic interventions that improve patient outcomes. Nevertheless, even with the current diversity of hemodynamic devices available, the PAC remains a valuable tool in a wide variety of clinical settings. The authors present a review exposing the benefits of the PAC, current clinical recommendations for its use, mortality and survival profile, its role in goal-directed therapy, and other applications of the PAC beyond cardiac surgery and the intensive care unit.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Artéria Pulmonar , Cateterismo de Swan-Ganz , Catéteres , Hemodinâmica , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA