Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45.423
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Medicine (Baltimore) ; 103(17): e37866, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38669430

RESUMO

To investigate the value of preoperative ultrasound combined with 99mTc-MIBI imaging for the diagnosis of ectopic intrathyroid parathyroid gland (ETPG) in patients with secondary hyperparathyroidism (SHPT). One hundred and eleven patients with SHPT who underwent total parathyroidectomy plus forearm transplantation from January 2015 to January 2022 in the Third Hospital of Hebei Medical University were selected. All patients underwent routine preoperative ultrasonography and 99mTc-MIBI imaging, and with pathological diagnosis as the gold standard, the clinical data of ETPG patients were selected, including clinical manifestations, laboratory tests, preoperative ultrasonography and 99mTc-MIBI imaging for localization and diagnosis, intraoperative exploration and postoperative pathology, and postoperative follow-up. To analyze the ultrasound manifestations of preoperative parathyroid hyperplasia and the results of 99mTc-MIBI imaging in patients with ETPG. Among 111 patients with SHPT, there were 5 patients with ETPG, 1 male and 4 females with a mean age of (45.00 ±â€…5.05) years, and 6 ectopic parathyroid glands were located in the thyroid gland. The incidence of ETPG was 4.5% (5/111), 4 were detected by ultrasound, 2 were not detected with a diagnostic accuracy of 66.7% (4/6), 3 were positive for 99mTc-MIBI imaging, 3 were negative with a diagnostic accuracy of 50.0% (3/6). Among them, one was not detected by ultrasound, but was positive for 99mTc-MIBI imaging, 2 with negative 99mTc-MIBI imaging, but all were detected by ultrasound, and one with negative 99mTc-MIBI imaging was detected by ultrasound but misdiagnosed as a thyroid nodule. A total of 5 ETPGs were detected by ultrasound combined with 99mTc-MIBI imaging, with a diagnostic accuracy of 83.3% (5/6). Patients' postoperative serum calcium and serum parathyroid hormone (PTH) levels were normalized or significantly decreased from preoperative levels. Ultrasound combined with 99mTc-MIBI imaging can achieve higher accuracy than either examination alone in the preoperative localization and diagnosis of ETPG in SHPT patients.


Assuntos
Coristoma , Hiperparatireoidismo Secundário , Glândulas Paratireoides , Tecnécio Tc 99m Sestamibi , Glândula Tireoide , Ultrassonografia , Humanos , Masculino , Feminino , Hiperparatireoidismo Secundário/diagnóstico por imagem , Hiperparatireoidismo Secundário/cirurgia , Pessoa de Meia-Idade , Glândulas Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/cirurgia , Ultrassonografia/métodos , Adulto , Coristoma/diagnóstico por imagem , Coristoma/complicações , Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/cirurgia , Compostos Radiofarmacêuticos , Cintilografia/métodos , Paratireoidectomia/métodos
2.
Hell J Nucl Med ; 27(1): 58-63, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38629818

RESUMO

Cerebrospinal fluid (CSF) shunting is an established long-term treatment option for hydrocephalus, and is one of the most commonly performed neurosurgical procedures in western countries.Despite advances in CSF shunt design and management, its failure rates remain high and is most commonly due to obstruction and infection.Cerebrospinal fluidshunt failure diagnosis should be prompt and accurate in establishing timely if its revision is appropriate. Radionuclide shuntography with technetium-99m-diethylenetriaminepetaacetic acid (99mTc-DTPA) is a useful technique for evaluation CSF shunts and management of patients presenting with shunt-related problems, in particular it can avoid unnecessary replacement interventions. Although its execution and interpretation require specific skills, we suggest its execution for the evaluation of device's patency. We here describe the radionuclide shuntography performed with recent hybrid multimodal technologies, with a procedure customized to a complicated patient with hydrocefalus and neoplastic disease. We suggest considering radionuclide shuntography in association with conventional imaging and strongly recommend the additional performance of single photon emission computed tomography/computed tomography (SPECT/CT) because it also provides valuable information to complete the interpretation of planar images.


Assuntos
Derivações do Líquido Cefalorraquidiano , Humanos , Derivações do Líquido Cefalorraquidiano/instrumentação , Hidrocefalia/diagnóstico por imagem , Hidrocefalia/cirurgia , Imagem Multimodal/métodos , Pentetato de Tecnécio Tc 99m , Masculino , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Compostos Radiofarmacêuticos , Cintilografia
3.
Methods Mol Biol ; 2794: 271-280, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38630236

RESUMO

Malformations of cortical development (MCDs) are a diverse group of disorders that result from abnormal neuronal migration, proliferation, and differentiation during brain development. Head computed tomography (CT) has limited use in the diagnosis of MCDs and should be reserved for selected cases with specific indications or when magnetic resonance imaging is not available or contraindicated. CT can detect brain calcifications associated with MCDs, thus helping in the differential diagnosis between acquired and genetic MCDs or in the identification of different genetic patterns. Moreover, CT can provide high-resolution images of the skull and bones, thus identifying associated malformations, such as craniosynostosis, inner and middle ear malformations, and vertebral anomalies. In this chapter, we review the CT scan technique, data analysis, and indications in the investigation of MCDs.


Assuntos
Malformações do Desenvolvimento Cortical , Osteocondrodisplasias , Humanos , Cintilografia , Análise de Dados
4.
Bratisl Lek Listy ; 125(5): 281-288, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38624052

RESUMO

AIM: We aimed to investigate the possible cardioprotective effects of paricalcitol (PR), its vitamin D receptor agonist, and vitamin D3 (VIT-D3) on an experimental model of doxorubicin (DX) cardiotoxicity by 99mTc-PYP scintigraphy, electrocardiographic (ECG) and biochemical methods. METHOD: Forty-two male Wistar/Albino rats (250‒300 g; aged 10‒12 weeks) were randomly separated into six groups, namely into control (CN), doxorubicin (DX), paricalcitol (PR), vitamin D3 (VIT-D3), paricalcitol + doxorubicin (PR+DX), and vitamin D3 + doxorubicin (VIT-D3+DX) groups. Cardiotoxicity was induced by three doses of DX (18 mg/kg, i.p.) at 24-hour intervals on days 18, 19 and 20. PR (0.5 ug/ kg, i.p) and VIT-D3 (5,000 IU/kg, i.p) were injected for 20 days before and after the application of DX (18 mg/kg, i.p.). On day 21 of the experiment, biochemical parameters [tumor necrosis factor TNF-alpha (TNF-α); interleukin-6 (IL-6), nitric oxide (NO), and cardiac troponin T (cTnT)], as well as ECG and scintigraphic (99mTc-PYP) features were assessed. RESULTS: Compared to CN, DX significantly raised TNF-α, IL-6, and NO in heart tissue, cTnT in serum, 99mTc-PYP uptake in the myocardium, and ECG parameters, specifically QRS complex duration, QT interval duration, and ST-segment amplitude, while also reducing heart rate (p<0.001). Pretreatment with PR and VIT-D3 mitigated these abnormalities produced by DX in the heart (p<0.001). CONCLUSION: Results show that vitamin D receptor agonist paricalcitol and vitamin D protect against DX-induced cardiotoxicity through anti-inflammatory and antioxidant effects (Fig. 4, Ref. 59). Text in PDF www.elis.sk Keywords: paricalcitol, doxorubicin, vitamin D, ECG, 99mTc-PYP scintigraphy, cardiotoxicity, inflammation.


Assuntos
Cardiotoxicidade , Ergocalciferóis , Receptores de Calcitriol , Ratos , Masculino , Animais , Cardiotoxicidade/tratamento farmacológico , Cardiotoxicidade/prevenção & controle , Receptores de Calcitriol/uso terapêutico , Ratos Wistar , Colecalciferol/farmacologia , Fator de Necrose Tumoral alfa/metabolismo , Interleucina-6 , Eletrocardiografia , Doxorrubicina/toxicidade , Antioxidantes/farmacologia , Cintilografia , Estresse Oxidativo
5.
Surgery ; 175(1): 228-233, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38563428

RESUMO

BACKGROUND: Fluorodeoxyglucose uptake on positron emission tomography imaging has been shown to be an independent risk factor for malignancy in thyroid nodules. More recently, a new positron emission tomography radiotracer-Gallium-68 DOTATATE-has gained popularity as a sensitive method to detect neuroendocrine tumors. With greater availability of this imaging, incidental Gallium-68 DOTATATE uptake in the thyroid gland has increased. It is unclear whether current guideline-directed management of thyroid nodules remains appropriate in those that are Gallium-68 DOTATATE avid. METHODS: We retrospectively reviewed Gallium-68 DOTATATE positron emission tomography scans performed at our institution from 2012 to 2022. Patients with incidental focal Gallium-68 DOTATATE uptake in the thyroid gland were included. Fine needle aspiration biopsies were characterized via the Bethesda System for Reporting Thyroid Cytopathology. Bethesda III/IV nodules underwent molecular testing (ThyroSeq v3), and malignancy risk ≥50% was considered positive. RESULTS: In total, 1,176 Gallium-68 DOTATATE PET scans were reviewed across 837 unique patients. Fifty-three (6.3%) patients demonstrated focal Gallium-68 DOTATATE thyroid uptake. Nine patients were imaged for known medullary thyroid cancer. Forty-four patients had incidental radiotracer uptake in the thyroid and were included in our study. Patients included in the study were predominantly female sex (75%), with an average age of 62.9 ± 13.9 years and a maximum standardized uptake value in the thyroid of 7.3 ± 5.3. Frequent indications for imaging included neuroendocrine tumors of the small bowel (n = 17), lung (n = 8), and pancreas (n = 7). Thirty-three patients underwent subsequent thyroid ultrasound. Sonographic findings warranted biopsy in 24 patients, of which 3 were lost to follow-up. Cytopathology and molecular testing results are as follows: 12 Bethesda II (57.1%), 6 Bethesda III/ThyroSeq-negative (28.6%), 1 Bethesda III/ThyroSeq-positive (4.8%), 2 Bethesda V/VI (9.5%). Four nodules were resected, revealing 2 papillary thyroid cancers, 1 neoplasm with papillary-like nuclear features, and 1 follicular adenoma. There was no difference in maximum standardized uptake value between benign and malignant nodules (7.0 ± 4.6 vs 13.1 ± 5.7, P = .106). Overall, the malignancy rate among patients with sonography and appropriate follow-up was 6.7% (2/30). Among patients with cyto- or histopathology, the malignancy rate was 9.5% (2/21). There were no incidental cases of medullary thyroid cancer. CONCLUSION: The malignancy rate among thyroid nodules with incidental Gallium-68 DOTATATE uptake is comparable to rates reported among thyroid nodules in the general population. Guideline-directed management of thyroid nodules remains appropriate in those with incidental Gallium-68 DOTATATE uptake.


Assuntos
Carcinoma Neuroendócrino , Tomografia por Emissão de Pósitrons , Cintilografia , Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Nódulo da Glândula Tireoide/patologia , Radioisótopos de Gálio , Estudos Retrospectivos , Neoplasias da Glândula Tireoide/diagnóstico , Biópsia por Agulha Fina , Carcinoma Neuroendócrino/diagnóstico por imagem , Carcinoma Neuroendócrino/terapia
6.
Clin Nucl Med ; 49(5): 451-453, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38557553

RESUMO

ABSTRACT: 131 I has been used effectively over the years in both diagnosis and therapy of differentiated thyroid cancer (DTC). Although whole-body scan with 131 I is a highly sensitive tool for detecting normal thyroid tissue and metastasis of DTC, it is not specific; therefore, false-positive images can be seen in clinical practice, and their recognition is critical for correct management. Evaluation of false-positive uptake is important because it may be confused with metastatic involvement. Here, we present a rare false-positive result of whole-body scan in a patient with DTC. To our knowledge, it is the first report on 131 I uptake of conjunctival concretions.


Assuntos
Adenocarcinoma , Neoplasias da Glândula Tireoide , Humanos , Imagem Corporal Total , Cintilografia , Neoplasias da Glândula Tireoide/patologia , Tireoidectomia , Adenocarcinoma/tratamento farmacológico , Radioisótopos do Iodo/uso terapêutico
7.
Clin Nucl Med ; 49(5): 438-441, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38574255

RESUMO

ABSTRACT: 123I-meta-iodobenzylguanidine (123I-MIBG) is extensively used for initial staging and response evaluation in children with neuroblastoma. Physiological uptake of 123I-MIBG occurs in the salivary glands, liver, adrenal gland, myocardium, bowel, and thyroid gland. 123I-MIBG cannot cross an intact blood-brain barrier. We present the rare case of a 3-year-old boy with neuroblastoma and meningeal metastases who underwent an 123I-MIBG scan for disease restaging that showed abnormal brain uptake. Abnormal MIBG uptake in the brain can occur if there is disruption of the blood-brain barrier either secondary to metastases or after damage to blood-brain barrier.


Assuntos
Iodobenzenos , Neuroblastoma , Criança , Masculino , Humanos , Pré-Escolar , 3-Iodobenzilguanidina , Cintilografia , Neuroblastoma/diagnóstico por imagem , Neuroblastoma/patologia , Encéfalo/diagnóstico por imagem , Encéfalo/patologia
10.
Clin Nucl Med ; 49(6): e301-e303, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38598541

RESUMO

ABSTRACT: Differentiated thyroid carcinoma constitutes over 90% of all thyroid cancers. The standard treatment approach involves total or near-total thyroidectomy with or without neck dissection followed by 131 I whole-body scintigraphy (WBS) to detect local or distant metastases. Radioiodine offers high sensitivity and specificity for detection of metastatic disease in well differentiated thyroid carcinoma. However, despite its high accuracy, 131 I WBS demonstrates false-positive results, mostly at inflammatory or infective site. These false-positive radioiodine accumulation can lead to misdiagnosis and unwarranted radioiodine treatment. This case presents localization of 131 I to the suture site granuloma leading to false-positive results on 131 I WBS.


Assuntos
Radioisótopos do Iodo , Metástase Linfática , Cintilografia , Imagem Corporal Total , Humanos , Diagnóstico Diferencial , Metástase Linfática/diagnóstico por imagem , Suturas/efeitos adversos , Granuloma/diagnóstico por imagem , Feminino , Pescoço/diagnóstico por imagem , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Pessoa de Meia-Idade , Masculino , Transporte Biológico
11.
Hemodial Int ; 28(2): 247-252, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38448766

RESUMO

Lu177-dotatate (Lutathera™) is a radioactive drug approved for the treatment of adults with gastro-entero-pancreatic neuroendocrine tumors and is predominantly renally excreted. Currently all patients receive 7400 MBq (200 mCi), and there are no guidelines for treating hemodialysis patients. We measured radioactivity prior to and post administration of two cycles of Lu177-dotatate in a hemodialysis patient, and radiation exposure to staff. We reduced the standard 7400 MBq by 33% for the first cycle and patient radioactivity fell by 40% following postdilution hemodiafiltration started 6 h post dosing, and by 45% for the second cycle and radioactivity fell by 47% with postdilution hemodiafiltration started 5 h post administration. By reducing the initial administered radioactivity, coupled with early dialysis, and choosing postdilution hemodiafiltration we were able to achieve radioactivity retention curves similar to those from patients with normal renal function receiving the standard administration of 7400 MBq.


Assuntos
Lutécio , Tomografia por Emissão de Pósitrons , Cintilografia , Diálise Renal , Adulto , Humanos , Lutécio/uso terapêutico , Compostos Radiofarmacêuticos/uso terapêutico
12.
Med J Malaysia ; 79(Suppl 1): 215-219, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38555908

RESUMO

This study is aimed to determine knowledge and practices on radiation protection among radiographers in nuclear medicine department. A cross-sectional survey was conducted among radiographers in nuclear medicine departments in four health institutions in Malaysia. A set of questionnaires was distributed to 17 respondents using convenience sampling. Approximately more than 75% and 44% - 56% of the radiographers have good knowledge of radiation protection and frequent adherence to radiation protection practices, respectively. Levels of education and length of service were statistically correlated with radiation protection knowledge and practices attributes (p < 0.05), respectively. More training is necessary for knowledge and practice improvement.


Assuntos
Medicina Nuclear , Proteção Radiológica , Humanos , Estudos Transversais , Cintilografia , Inquéritos e Questionários
13.
Med Phys ; 51(4): 2905-2923, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38456622

RESUMO

BACKGROUND: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. PURPOSE: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. METHODS: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100-1000 Hz for pulsed electrons and 10-20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams (86Kr+26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. RESULTS: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. The HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35-40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. CONCLUSIONS: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.


Assuntos
Prótons , Radiometria , Cintilografia , Dosagem Radioterapêutica
14.
Sci Rep ; 14(1): 5310, 2024 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-38438474

RESUMO

Our study aimed to compare bone scintigraphy and dual-layer detector spectral CT (DLCT) with multiphase contrast enhancement for the diagnosis of osteoblastic bone lesions in patients with prostate cancer. The patients with prostate cancer and osteoblastic bone lesions detected on DLCT were divided into positive bone scintigraphy group (pBS) and negative bone scintigraphy group (nBS) based on bone scintigraphy. A total of 106 patients (57 nBS and 49 pBS) was included. The parameters of each lesion were measured from DLCT including Hounsfield unit (HU), 40-140 keV monochromatic HU, effective nuclear numbers (Zeff), and Iodine no water (InW) value in non-contrast phase (N), the arterial phase (A), and venous phase (V). The slope of the spectral curve at 40 and 100 keV, the different values of the parameters between A and N phase (A-N), V and N phase (V-N), and hybrid prediction model with multiparameters were used to differentiate pBS from nBS. Receiver operating characteristic analysis was performed to compare the area under the curve (AUC) for differentiating the pBS group from the nBS group. The value of conventional HU values, slope, and InW in A-N and V-N, and hybrid model were significantly higher in the pBS group than in the nBS group. The hybrid model of all significant parameters had the highest AUC of 0.988, with 95.5% sensitivity and 94.6% specificity. DLCT with arterial contrast enhancement phase has the potential to serve as an opportunistic screening tool for detecting positive osteoblastic bone lesions, corresponding to those identified in bone scintigraphy.


Assuntos
Doenças Ósseas , Doenças das Cartilagens , Iodo , Neoplasias da Próstata , Masculino , Humanos , Detecção Precoce de Câncer , Tomografia Computadorizada por Raios X , Programas de Rastreamento , Neoplasias da Próstata/diagnóstico por imagem , Cintilografia
15.
Clin Nucl Med ; 49(5): 419-426, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38546331

RESUMO

INTRODUCTION: 123 I-MIBG has been well established as a functional imaging tool, and 131 I-MIBG therapy is being considered for catecholamine-secreting tumors. Tumors with the characteristics of a noradrenergic biochemical phenotype, small, malignant, metastatic, extra-adrenal, bilateral, and hereditary, especially SDHx -related tumors, are reported to correlate with reduced MIBG uptake. However, the potential molecular mechanisms influencing MIBG uptake have been poorly studied. PATIENTS AND METHODS: To identify critical genes that may enhance MIBG accumulation in pheochromocytomas (PCCs), we performed RNA-seq analyses for 16 operated patients with PCCs (6 MIBG-negative and 10 MIBG-positive) combined with RT-qPCR for 27 PCCs (5 MIBG-negative and 22 MIBG-positive) and examined primary cultures of the surgical tissues. RESULTS: In the present study, 6 adrenal nodules of 66 nodules surgically removed from 63 patients with PCCs (9%) were MIBG negative. MIBG, a guanethidine analog of norepinephrine, can enter chromaffin cells through active uptake via the cellular membrane, be deposited in chromaffin granules, and be released via Ca 2+ -triggered exocytosis from adrenal chromaffin cells. When we compared expression of several catecholamine biosynthesis and secretion-associated genes between MIBG-negative and MIBG-positive tumors using transcriptome analyses, we found that neuropeptide Y, which is contained in chromaffin granules, was significantly increased in MIBG-negative tumors. NPY stimulated norepinephrine secretion dose-dependently in primary cell culture derived from MIBG-positive PCC. In our study, MIBG-negative PCCs were all norepinephrine-hypersecreting tumors. CONCLUSIONS: These data indicate that NPY upregulation in PCCs may stimulate chromaffin granule catecholamine secretion, which is associated with false-negative 123 I-MIBG scintigraphy.


Assuntos
Neoplasias das Glândulas Suprarrenais , Feocromocitoma , Humanos , Feocromocitoma/patologia , 3-Iodobenzilguanidina , Neuropeptídeo Y/metabolismo , Neoplasias das Glândulas Suprarrenais/metabolismo , Catecolaminas/metabolismo , Cintilografia , Norepinefrina/metabolismo
16.
Q J Nucl Med Mol Imaging ; 68(1): 3-22, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38445832

RESUMO

Congenital anomalies of the kidney and urinary tract, as well as urinary infections, are very frequent in children. After the clinical and laboratory evaluation, the first imaging procedure to be done is a renal and bladder ultrasound, but afterwards, a main contribution comes from nuclear medicine. Through minimally invasive and sedation-free procedures, nuclear medicine allows the evaluation of the functional anatomy of the urinary tract, and the quantification of renal function and drainage. If pediatric dosage cards provided by scientific societies are used, radiation exposure can also be low. In the pediatric conditions previously mentioned, nuclear medicine is used both for initial diagnosis and follow-up, mostly in cases of suspicion of ureteropelvic or ureterovesical junction syndromes, as well as vesicoureteral reflux or renal scars of febrile infectious episodes. Pediatric nephro-urology constitutes a significant workload of pediatric nuclear medicine departments. The following paragraphs are a revision of the renal radiopharmaceuticals, as well as the nuclear nephro-urology procedures - dynamic and static renal scintigraphy, and direct and indirect radionuclide cystography. A summary of the techniques, main indications, interpretation criteria and pitfalls will be provided. Some future directions for the field are also pointed out, among which the most relevant is the need for nuclear medicine professionals to use standardized protocols and integrate multidisciplinary teams with other pediatric and adult health professionals that manage these life-long pediatric pathologies, which are recognized as an important cause of adult chronic kidney disease.


Assuntos
Medicina Nuclear , Urologia , Criança , Humanos , Medicina Nuclear/métodos , Urologia/métodos , Cintilografia , Rim/diagnóstico por imagem , Diagnóstico por Imagem
17.
Lancet Digit Health ; 6(4): e251-e260, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38519153

RESUMO

BACKGROUND: The diagnosis of cardiac amyloidosis can be established non-invasively by scintigraphy using bone-avid tracers, but visual assessment is subjective and can lead to misdiagnosis. We aimed to develop and validate an artificial intelligence (AI) system for standardised and reliable screening of cardiac amyloidosis-suggestive uptake and assess its prognostic value, using a multinational database of 99mTc-scintigraphy data across multiple tracers and scanners. METHODS: In this retrospective, international, multicentre, cross-tracer development and validation study, 16 241 patients with 19 401 scans were included from nine centres: one hospital in Austria (consecutive recruitment Jan 4, 2010, to Aug 19, 2020), five hospital sites in London, UK (consecutive recruitment Oct 1, 2014, to Sept 29, 2022), two centres in China (selected scans from Jan 1, 2021, to Oct 31, 2022), and one centre in Italy (selected scans from Jan 1, 2011, to May 23, 2023). The dataset included all patients referred to whole-body 99mTc-scintigraphy with an anterior view and all 99mTc-labelled tracers currently used to identify cardiac amyloidosis-suggestive uptake. Exclusion criteria were image acquisition at less than 2 h (99mTc-3,3-diphosphono-1,2-propanodicarboxylic acid, 99mTc-hydroxymethylene diphosphonate, and 99mTc-methylene diphosphonate) or less than 1 h (99mTc-pyrophosphate) after tracer injection and if patients' imaging and clinical data could not be linked. Ground truth annotation was derived from centralised core-lab consensus reading of at least three independent experts (CN, TT-W, and JN). An AI system for detection of cardiac amyloidosis-associated high-grade cardiac tracer uptake was developed using data from one centre (Austria) and independently validated in the remaining centres. A multicase, multireader study and a medical algorithmic audit were conducted to assess clinician performance compared with AI and to evaluate and correct failure modes. The system's prognostic value in predicting mortality was tested in the consecutively recruited cohorts using cox proportional hazards models for each cohort individually and for the combined cohorts. FINDINGS: The prevalence of cases positive for cardiac amyloidosis-suggestive uptake was 142 (2%) of 9176 patients in the Austrian, 125 (2%) of 6763 patients in the UK, 63 (62%) of 102 patients in the Chinese, and 103 (52%) of 200 patients in the Italian cohorts. In the Austrian cohort, cross-validation performance showed an area under the curve (AUC) of 1·000 (95% CI 1·000-1·000). Independent validation yielded AUCs of 0·997 (0·993-0·999) for the UK, 0·925 (0·871-0·971) for the Chinese, and 1·000 (0·999-1·000) for the Italian cohorts. In the multicase multireader study, five physicians disagreed in 22 (11%) of 200 cases (Fleiss' kappa 0·89), with a mean AUC of 0·946 (95% CI 0·924-0·967), which was inferior to AI (AUC 0·997 [0·991-1·000], p=0·0040). The medical algorithmic audit demonstrated the system's robustness across demographic factors, tracers, scanners, and centres. The AI's predictions were independently prognostic for overall mortality (adjusted hazard ratio 1·44 [95% CI 1·19-1·74], p<0·0001). INTERPRETATION: AI-based screening of cardiac amyloidosis-suggestive uptake in patients undergoing scintigraphy was reliable, eliminated inter-rater variability, and portended prognostic value, with potential implications for identification, referral, and management pathways. FUNDING: Pfizer.


Assuntos
Amiloidose , Cardiomiopatias , Humanos , Amiloidose/diagnóstico por imagem , Amiloidose/metabolismo , Inteligência Artificial , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/metabolismo , Prognóstico , Cintilografia , Compostos Radiofarmacêuticos , Estudos Retrospectivos
18.
Clin Nucl Med ; 49(5): 454-456, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38465961

RESUMO

ABSTRACT: Extravasation of the radiopharmaceutical during peptide receptor radionuclide therapy infusion is an unwanted infrequently reported event. We present the case of a 74-year old woman with a neuroendocrine tumor who was referred for peptide receptor radionuclide therapy. During intravenous infusion of 7.4 GBq [ 177 Lu]Lu-HA-DOTATATE in the upper right arm, extravasation of the radiopharmaceutical occurred through a displaced intravenous catheter. Planar scintigraphy showed pooling of radioactivity in the right upper arm. After 24 hours, the swelling in the arm was decreased; however, erythema was increased. One week later, symptoms had disappeared, and the patient did not experience any complications during follow-up of 11 months.


Assuntos
Lutécio , Tumores Neuroendócrinos , Compostos Organometálicos , Tomografia por Emissão de Pósitrons , Cintilografia , Feminino , Humanos , Idoso , Compostos Radiofarmacêuticos , Octreotida/efeitos adversos , Radioisótopos , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/radioterapia , Receptores de Peptídeos , Compostos Organometálicos/efeitos adversos
19.
Radiol Phys Technol ; 17(1): 269-279, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38336939

RESUMO

To improve image quality for low-count bone scintigraphy using deep learning and evaluate their clinical applicability. Six hundred patients (training, 500; validation, 50; evaluation, 50) were included in this study. Low-count original images (75%, 50%, 25%, 10%, and 5% counts) were generated from reference images (100% counts) using Poisson resampling. Output (DL-filtered) images were obtained after training with U-Net using reference images as teacher data. Gaussian-filtered images were generated for comparison. Peak signal-to-noise ratio (PSNR) and structural similarity (SSIM) to the reference image were calculated to determine image quality. Artificial neural network (ANN) value, bone scan index (BSI), and number of hotspots (Hs) were computed using BONENAVI analysis to assess diagnostic performance. Accuracy of bone metastasis detection and area under the curve (AUC) were calculated. PSNR and SSIM for DL-filtered images were highest in all count percentages. BONENAVI analysis values for DL-filtered images did not differ significantly, regardless of the presence or absence of bone metastases. BONENAVI analysis values for original and Gaussian-filtered images differed significantly at ≦25% counts in patients without bone metastases. In patients with bone metastases, BSI and Hs for original and Gaussian-filtered images differed significantly at ≦10% counts, whereas ANN values did not. The accuracy of bone metastasis detection was highest for DL-filtered images in all count percentages; the AUC did not differ significantly. The deep learning method improved image quality and bone metastasis detection accuracy for low-count bone scintigraphy, suggesting its clinical applicability.


Assuntos
Neoplasias Ósseas , Aprendizado Profundo , Humanos , Melhoria de Qualidade , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Cintilografia
20.
Clin Imaging ; 108: 110099, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38401295

RESUMO

Whole-Body Magnetic Resonance Imaging (WB-MRI) has cemented its position as a pivotal tool in oncological diagnostics. It offers unparalleled soft tissue contrast resolution and the advantage of sidestepping ionizing radiation. This review explores the diverse applications of WB-MRI in oncology. We discuss its transformative role in detecting and diagnosing a spectrum of cancers, emphasizing conditions like multiple myeloma and cancers with a proclivity for bone metastases. WB-MRI's capability to encompass the entire body in a singular scan has ushered in novel paradigms in cancer screening, especially for individuals harboring hereditary cancer syndromes or at heightened risk for metastatic disease. Additionally, its contribution to the clinical landscape, aiding in the holistic management of multifocal and systemic malignancies, is explored. The article accentuates the technical strides achieved in WB-MRI, its myriad clinical utilities, and the challenges in integration into standard oncological care. In essence, this review underscores the transformative potential of WB-MRI, emphasizing its promise as a cornerstone modality in shaping the future trajectory of cancer diagnostics and treatment.


Assuntos
Neoplasias Ósseas , Mieloma Múltiplo , Humanos , Imageamento por Ressonância Magnética/métodos , Imagem Corporal Total/métodos , Neoplasias Ósseas/patologia , Cintilografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA