Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 131
Filtrar
1.
Rev. bras. ciênc. vet ; 28(1): 61-66, jan./mar. 2021. il.
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1368827

RESUMO

Plasma levels of hematocrit, total plasma protein, fibrinogen, creatine phosphokinase, aspartate transferase, and lactate were analyzed in blood samples of 85 Crioula breed foals, from birth to two years of age. The animals were divided into age groups: G1 (up to 15 days of age; n=70), G2 (from 16 days to one month of age; n=67), G3 (between one and three months of age; n=75), G4 (between three and six months of age; n=64), G5 (between six and nine months of age; n=59), G6 (between nine and 18 months of age; n=39), and G7 (between 18 months and two years of age; n=17). These groups were statistically analyzed by one-way variance analysis (ANOVA) and Tukey's test. Male and female means were compared by Student's t-test. Hematocrit levels were significantly higher up to 90 days of age and in G7 females. Total plasma proteins increased significantly in groups 3, 4, 6, and 7. The highest fibrinogen levels were found in G1. Yet for creatine phosphokinase, the highest concentrations were detected in G5, whereas those of aspartate aminotransferase in G7. The levels of this enzyme remained similar from 30 days to two years of age. Lactate concentrations were higher in G3. We concluded that the sex of the animal had no significant effect on laboratory test interpretations. By contrast, the age of the animal should be considered since relevant variations were observed with time. Nevertheless, specific tables for each analysis should be consulted for interpretation of results.


Com o propósito de estabelecer valores de hematócrito, proteínas plasmáticas totais, fibrinogênio, creatina quinase , aspartato transferase e lactato em potros da raça Crioula, do nascimento até os dois anos, utilizaram-se amostras sanguíneas de 85 animais, divididos pela estratificação etária: Grupo 1 (G1) Até 15 dias de vida (n=70); grupo 2 (G2), entre 16 dias até um mês (n=67); grupo 3 (G3), entre 1 e 3 meses (n=75); grupo 4 (G4), entre 3 e 6 meses (n=64); grupo 5 (G5), entre 6 e 9 meses (n=59); grupo 6 (G6), entre 9 e 18 meses (n=39); e grupo 7 (G7), entre 18 meses até 2 anos (n=17). Foi realizado estudo estatístico entre os grupos pela análise de variância unidirecional (one-wayANOVA), complementada pelo teste de Tukey. Para comparação das médias entre os sexos utilizou-se o teste t de Student. O hematócrito foi significativamente mais elevado até os 90 dias e nas fêmeas do G7. Para proteínas plasmáticas totais, notou-se aumento significativo nos grupos 3, 4, 6 e 7. Os valores de fibrinogênio foram maiores no G1. A CK apresentou maior concentração no G5 e a AST no G7. A AST assumiu valores semelhantes dos 30 dias até os 2 anos. A concentração de lactato foi mais elevada no G3. Conclui-se que na interpretação dos exames laboratoriais de potros da raça crioula, o gênero não interfere significativamente nos resultados, porém a idade deve ser considerada devido à ocorrência de variações relevantes. Recomenda-se que para interpretação sejam consultadas tabelas específicas para cada análise.


Assuntos
Animais , Análise Química do Sangue/veterinária , Coleta de Amostras Sanguíneas/veterinária , /métodos , Cavalos/sangue , Fibrinogênio/análise , Proteínas Sanguíneas/análise , Creatina Quinase/análise , Testes Laboratoriais/análise , Hematócrito/veterinária , Testes Hematológicos/veterinária
2.
Equine Vet J ; 53(3): 488-494, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32770680

RESUMO

BACKGROUND: Blood collection by indwelling intravenous catheter (IVC) avoids repeated venipuncture, which could cause thrombophlebitis risk, anxiety and pain in patients. OBJECTIVES: To compare blood gas parameters, electrolytes, glucose, lactate and haematocrit concentration obtained from venous blood samples collected via a jugular IVC by push-pull (PP) technique to those obtained by venipuncture in hospitalised foals, at the time of catheter placement (T0) and 24 hours after the beginning of intravenous therapy (T24). STUDY DESIGN: Prospective observational study. METHODS: Paired blood samples were drawn from hospitalised foals at T0 and T24. In each foal, one venous blood sample was collected via IVC by the following PP technique: 2.4 mL of blood was aspirated and immediately reinfused through the catheter three times consecutively, then 1 mL of blood was collected using a 1 mL heparinised syringe. Thereafter, another sample was collected by direct venipuncture of the contralateral jugular vein, with an identical 1 mL heparinised syringe, with a 1-inch, 20-G needle. All samples were analysed with an automated blood gas analyser within 10 minutes of collection. The agreement between the two techniques was assessed by Bland-Altman analysis and intraclass correlation coefficient (ICC). RESULTS: The level of agreement of blood gas values obtained by the two different techniques was high with very small bias and clinically acceptable ICC (>0.907 at T0; >0.794 at T24) for all variables, except for haematocrit (bias -3.52 at T0; -2.44 at T24) and PvO2 at T0 and T24 (ICC 0.669 and 0.733, respectively). MAIN LIMITATIONS: Potential sub-clinical catheter-related complications were not investigated by ultrasound or bacterial culture of the catheter; short duration of the study. CONCLUSIONS: PP technique appears to be acceptable for collection of blood samples for venous blood gas parameters, as well as electrolytes, glucose and lactate in sick neonatal foals.


Assuntos
Ácido Láctico , Flebotomia , Animais , Coleta de Amostras Sanguíneas/veterinária , Eletrólitos , Glucose , Cavalos , Recém-Nascido , Flebotomia/veterinária
3.
Braz. j. biol ; 81(2): 241-245, 2021. tab
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1153370

RESUMO

Pet rabbits have increased their popularity in a lot of countries. However, most of the laboratory profiles in rabbit medicine come from the observations made in rabbit as biomodels or meat production. So that further researches are necessary to obtain reference values for hematology and biochemical profiles in pet rabbits and the different breeds, especially, in relation to acid-base balance. The aim of this report was to offer the mean values of the main parameters connected with acid-base profile in Netherland Dwarf breed. Thirty-five healthy rabbits (15 males and 20 females) were studied. Venous blood sample from lateral saphenous vein was analyzed to measure: haematocrit, haemoglobin, blood urea nitrogen, glucose, blood pH, partial pressure of CO2 (pCO2), total CO2, ions bicarbonate, chloride, sodium, potassium, base excess and anion Gap. Results showed a shorter range that those reported by different researchers. Moreover, differences between genders were showed in pCO2, its values were higher in males. It may be associated with a greater cellular metabolism. Values obtained in this research should be taken into account by veterinary clinicians for this breed in their clinical assessments. Besides, these values provide new results in parameters with few reference values.


A popularidade de coelhos como animais de estimação aumentou em muitos países. No entanto, a maioria dos perfis de laboratório em medicina de coelhos advém das observações de biomodelos animais ou da produção de carne. Assim, são necessárias pesquisas adicionais para obter valores de referência para hematologia e perfis bioquímicos em coelhos de estimação, e das diferentes raças, especialmente, em relação ao equilíbrio ácido-base. O objetivo deste relatório foi oferecer os valores médios dos principais parâmetros ligados ao perfil ácido-base na raça Anã Holandês. Trinta e cinco coelhos saudáveis ​​(15 machos e 20 fêmeas) foram estudados. A amostra de sangue venoso da veia safena lateral foi analisada para mensuração: hematócrito, hemoglobina, nitrogênio ureico sanguíneo, glicose, pH sanguíneo, pressão parcial de CO2 (pCO2), CO2 total, íons bicarbonato, cloreto, sódio, potássio, excesso de base e ânion Gap. Os resultados apresentaram um intervalo menor do que aqueles relatados por diferentes pesquisadores. Além disso, as diferenças entre os gêneros foram mostradas na pCO2, seus valores foram maiores no sexo masculino. Pode estar associado a um maior metabolismo celular. Os valores obtidos nesta pesquisa devem ser levados em consideração pelos clínicos veterinários para esta raça em suas avaliações clínicas. Além disso, esses valores fornecem novos resultados em parâmetros com poucos valores de referencia.


Assuntos
Animais , Masculino , Feminino , Coelhos , Potássio/sangue , Sódio/sangue , Equilíbrio Ácido-Base , Animais de Estimação/sangue , Valores de Referência , Coleta de Amostras Sanguíneas/veterinária
4.
Acta sci. vet. (Impr.) ; 49: Pub. 1815, 2021. graf, tab
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1363861

RESUMO

Measuring metabolic parameters in the blood has been an indispensable tool for assessing the productive and health status of dairy cows for more than 100 years. The values of laboratory parameters depend on various preanalytical, analytical and postanalytical factors. The most important preanalytical factors are sample transport time and temperature, hemolysis, anticoagulant type, and sample volume. Preanalytical factors can lead to reduced stability of the analyte in the sample, which changes their concentration. Loss of stability changes the time of storage and manipulation of the sample, which determines the criteria for its acceptance or rejection. The two stability indicators are stability limit and maximum permissible instability. A stability limit (SL) is defined as the period of time in which a property variation does not exceed a maximum permissible instability (MPI). The aim of this study was to determine the SL and MPI for each analyte in the blood serum of cows and to determine whether SL differs in the function of the presence of preanalytical errors in the blood sample. Three hundred samples of dairy cow origin in different periods of lactation participated in this research. They were classified into 6 groups of 50 samples: according to the time from sampling to processing in the laboratory (0-4 h, 4-8 h and over 8 h; all transported on dry ice, protected from environmental factors, without preanalytical errors) and according to the presence of preanalytical errors (group with hemolysis, a group transported at ambient temperature and a group with a small sample volume). Each sample was aliquoted in two portions. One portion was left at +4°C and tested once a day for 6 days of sample storage, and the second portion, placed at -20°C, was tested once a month for 6 months. The MPI had a value ranging from 1.51 to 8.4. Metabolic profile analytes with lower MPI values (1.51-3.22) were albumin (ALB), total protein (TPROT), UREA, glucose (GLU), calcium (Ca), and phosphorus (P). Higher MPI values (5.1-8.4) were found for nonesterified fatty acids (NEFA), beta-hydroxybutirate (BHB), cholesterol (CHOL), triglycerides (TGC), total bilirubin (TBIL) and aspartat aminotransferase (AST). For most parameters, we can conclude that their PD% changed faster in storage conditions at +4°C compared to the regime of -20°C. The largest number of biochemical analytes in bovine blood serum shows preserved stability in the first 6 days at +4°C or 6 months at -20°C if transported to the laboratory within 8 h after sampling in ideal conditions and without the action of preanalytical errors. Prolonged transport under ideal conditions or the existence of preanalytical errors such as transport at room temperature, hemolysis or small sample volume shorten the stability of the ALB, NEFA, GLU, UREA and P. Concentration of all analytes decreases during the stability test except for UREA, NEFA, BHB and for CHOL and TGC in some groups. Variations in parameters such as BHB, NEFA, TBIL, AST, and Ca have shown potential clinical significance. At storage conditions at +4°C, clinically significant variations at at least one measurement point were found for AST (7.5% of samples), BHB (6.1% of samples), NEFA (9.9% of samples) and for TBIL (in 7% of samples). This study can help define acceptable delay times and storage conditions for bovine blood samples, which is of great importance because in working with farm animals it is often not possible to take samples in a short time and deliver them to the laboratory, and samples are often burdened with certain preanalytical errors with limited possibilities of re-sampling.(AU)


Assuntos
Animais , Feminino , Bovinos , Preservação de Sangue/veterinária , Coleta de Amostras Sanguíneas/veterinária , Soro , Indicadores e Reagentes
5.
Rev. bras. ciênc. vet ; 27(3): 146-149, jul./set. 2020. il.
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1377518

RESUMO

Mugil curema is a teleost fish often found in coastal, estuarine and lagoon regions throughout the Brazilian coast. Blood parameters may be used as health and welfare indicators of the fish, as well as the environment they live in. The aim of this study was to verify the hematologic profile of the M.curema along 18 months in estuary waters from the north coast of the state of Santa Catarina in the south of Brazil. A total of 133 M. curema fish were captured from March 2016 to August 2017. Erythrogram, leukogram, thrombocytogram, hematocrit percentage, hemoglobin dosage, total plasma protein dosage, mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH) and medium corpuscular hemoglobin concentration (MCHC) were analyzed. There was no significant difference (P>0.05) on the total number of erythrocytes between the fish gender. However, there was difference on the hematocrit between males and indefinite gender fish. The influences of temporal and geographical space, among the values of hematological parameters, in the different studies of the Brazilian coast are discussed.. The present research is an important contribution to establish a hematological pattern for M. curema. The local population of the studied fish has a proper behavior in hematological descriptors, which is different from other Brazilian coast studies with the same fish species.


Mugil curema é um peixe teleósteo, abundante em regiões costeiras, estuarinas e lagunares, em todo o litoral brasileiro. Os parâmetros sanguíneos podem ser usados como indicadores da saúde e do bem-estar dos peixes, bem como do ambiente onde estes vivem. O objetivo deste estudo foi verificar o perfil hematológico de M. curema ao longo de 18 meses, em águas estuarinas, no Litoral norte do estado de Santa Catarina, sul do Brasil. Um total de 133 peixes foram capturados, entre março de 2016 e agosto de 2017, para realização de eritrograma, leucograma, trombocitograma, porcentagem de hematócrito, dosagem de hemoglobina, dosagem de proteína plasmática total, volume corpuscular médio (VCM), hemoglobina corpuscular média (HCM) e concentração de hemoglobina corpuscular média (CHCM). Não houve diferença significativa (P>0,05) entre o número total de eritrócitos entre machos e fêmeas. No entanto, houve diferença no hematócrito, entre machos e peixes de sexo indeterminado. As influências do espaço temporal e geográfico, entre os valores dos parâmetros hematológicos, nos diferentes estudos do litoral brasileiro são discutidas. A presente investigação é importante contribuição para o estabelecimento de um padrão hematológico para M. curema. A população local de peixes estudada tem comportamento próprio em descritores hematológicos, diferenciado de outros estudos no litoral brasileiro para a mesma espécie.


Assuntos
Animais , Contagem de Células Sanguíneas/veterinária , Coleta de Amostras Sanguíneas/veterinária , Peixes/sangue , Testes Hematológicos/veterinária , Hematologia/estatística & dados numéricos , Padrões de Referência , Estuários , Análise Espaço-Temporal
6.
Artigo em Inglês | MEDLINE | ID: mdl-32557512

RESUMO

OBJECTIVE: 1) To evaluate agreement for electrolyte measurements in goats between a handheld point-of-care analyzer (Abaxis VetScan i-STAT 1) (POC) and a benchtop blood gas analyzer (Opti CCA-TS2) (VBG) and 2) to evaluate effect of sample type on electrolytes values reported by both analyzers. MATERIAL AND METHODS: In 21 hospitalized caprine patients and 9 healthy research goats, blood samples were collected into heparin-containing tubes (Sodium Heparin 33 IU/2 ml) (TUBE) and a heparinized syringe (Sodium Heparin 430 IU/ml) (SYRINGE). Samples were analyzed using a POC analyzer as well as VBG. Analyzer results were compared using Bland-Altman analysis and Pearson correlation. Comparison between samples was performed using repeated measures ANOVA. RESULTS: Between analyzers, TUBE yielded a bias (95 % limits of agreement) of 0.07 mmol/l (-4.37 to 4.52) for sodium, while SYRINGE yielded a bias of -6.13 mmol/l (-11.04 to -1.22). Comparison of potassium yielded a bias of 0.09 mmol/l (-0.5 to 0.67) and 0.08 mmol/l (-0.4 to 0.56) for TUBE and SYRINGE, respectively. Comparison of ionized calcium showed a bias of 0.05 mmol/l (0.01-0.1) and -0.02 mmol/l (-0.18 to 0.14) for TUBE and SYRINGE, respectively. Between sample types, the POC yielded a bias of 5.13 mmol/l (0.18-10.09) for sodium, 0.04 mmol/l (-0.12 to 0.2) for potassium, and 0.40 mmol/l (0.12-0.68) for ionized calcium. CONCLUSION AND CLINICAL RELEVANCE: The POC exhibited clinically negligible bias for electrolyte analysis as compared to VBG. Ionized calcium concentrations were lower in self-prepared heparinized syringes than in heparin-containing tubes, suggesting an effect of heparin concentration on ionized calcium.


Assuntos
Gasometria , Coleta de Amostras Sanguíneas , Eletrólitos/sangue , Cabras/sangue , Animais , Gasometria/métodos , Gasometria/veterinária , Coleta de Amostras Sanguíneas/instrumentação , Coleta de Amostras Sanguíneas/veterinária , Heparina/química , Sistemas Automatizados de Assistência Junto ao Leito
7.
J Dairy Sci ; 103(6): 5509-5513, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32307153

RESUMO

The objectives of this study were to describe the stability of bovine whole-blood electrolytes, glucose, and lactate in samples collected in lithium heparin tubes and stored in thermoconductive modules immersed in ice water. A total of 99 Jersey cows (40 first-parity, 18 second-parity, and 41 third-parity or greater cows) from a commercial dairy farm in West Texas were enrolled between June and July 2018. Blood was collected from the jugular vein using a 60-mL polypropylene syringe and equally distributed into 5 spray-dried evacuated lithium heparin tubes. Baseline samples were analyzed within 90 s of collection using a benchtop blood gas analyzer. The remaining 4 tubes were stored in a thermoconductive, passive-temperature-regulating module inside a cooler with ice water. At 30 min and 2, 4, and 8 h post-collection, samples were removed from the temperature-regulating module, gently inverted for 10 s, and analyzed. Repeated-measures models were built to evaluate the effect of time on the stability of ionized Ca (iCa), ionized Mg (iMg), Na, K, Cl, glucose, and lactate. Most of the analytes investigated remained stable up to 8 h under ice water storage conditions before analysis, including iCa, iMg, Cl, glucose, and lactate. However, Na and K were significantly affected by delayed analysis: Na remained stable up to 4 h post-collection, but K was not stable starting at 2 h post-collection. The results of this study are useful in helping future researchers and consultants to recognize acceptable time delays between whole blood collection and processing or analysis for electrolytes, glucose, and lactate.


Assuntos
Coleta de Amostras Sanguíneas/veterinária , Bovinos/sangue , Eletrólitos/sangue , Heparina/química , Animais , Gasometria/veterinária , Glicemia/análise , Cálcio/sangue , Cloretos/sangue , Feminino , Ácido Láctico/sangue , Lítio/química , Magnésio/sangue , Potássio/sangue , Refrigeração/veterinária , Sódio/sangue , Texas , Fatores de Tempo
8.
J Feline Med Surg ; 22(12): 1121-1128, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32141375

RESUMO

OBJECTIVES: This research aimed to evaluate the performance of a closed blood collection system and to compare it with an open system in terms of feasibility, tolerability by the donor, quality of blood collected and bacterial contamination. METHODS: Eight feline blood donors were prospectively and randomly subjected to both collection methods. Heart rate (HR), respiratory rate (RR) and blood pressure (BP) were evaluated before sedation, after sedation and after blood collection. The duration of the donation, the formation of a hematoma, and the degree of hemolysis and packed cell volume (PCV) of each blood unit were evaluated. Aliquot samples were aseptically collected from each unit and tested for bacterial contamination by culture and PCR on days 0, 14 and 28 of storage. RESULTS: There was no significant difference between collection methods for HR and RR at any time point. Before sedation, the mean systolic BP was significantly higher with the closed system (closed 169 mmHg, open 137 mmHg; P = 0.003). The average duration of collection was significantly shorter with the closed system (closed 3 mins 10 s, open 8 mins; P = 0.035); however, the prevalence of a successful blood collection with a single venipuncture and hematoma formation were not significantly different between systems. The mean unit PCV was significantly higher with the open system (closed 31%, open 34%; P = 0.026). On bacterial culture, 15/16 units were negative at all time points (closed 7; open 8). Using PCR, 5/16 units were positive for Ralstonia species for at least one time point (closed 3; open 2). CONCLUSIONS AND RELEVANCE: Our designed closed system appears to be well adapted to feline blood collection and was well tolerated by the donors, performing similarly to an open system, and could represent a valuable clinical device for the development of a feline blood bank, namely feline blood storage.


Assuntos
Análise Química do Sangue/veterinária , Coleta de Amostras Sanguíneas/veterinária , Sangue/microbiologia , Gatos/sangue , Controle de Qualidade , Animais , Bactérias/isolamento & purificação , Coleta de Amostras Sanguíneas/instrumentação , Coleta de Amostras Sanguíneas/métodos , Estudos de Viabilidade , Estudos Prospectivos , Distribuição Aleatória
9.
Prensa méd. argent ; 106(2): 134-140, 20200000. tab
Artigo em Inglês | LILACS, BINACIS | ID: biblio-1369504

RESUMO

The study designed to evaluated the activity of pancreatic exocrine enzymes in diabetic male rats induced by alloxan. The hyperglycaemia was induced in forty-five rats after fasting of the animals for 24 hours by single intraperitoneal (i.p) injection of Alloxan100mg/kg B.W., three days after injection fasting blood glucose was measured when the concentration higher than 150mg/dL, were considered as hyperglycemic/ diabetes. A total of sixty adult male rats (45 diabetes and 15 non- diabetes) divided in to two groups as follows. The first group serves as control groups (15 animals) will be single i.p injection with distilled water. the second group diabetic groups (45 animals from first experiment) were subdivided into three subgroups as following (15 for each). Group (G1), Group (G2) and Group (G3) serves as 20, 40- and 60-days diabetic animals respectively. The blood samples collection were take through cardiac puncture technique from each rat for each period days for measurement the following parameters: (Serum glucose, total protein, insulin, cholesterol, albumin, triglyceride, LDL-C, HDL-C and VLDL-C) concentration, the rats pancreatic tissue were be taken for measured tissue pancreatic lipase, amylase, and trypsin concentration. The results demonstrate a significant increase in serum glucose concentration and a decrease in serum insulin and total protein in the diabetic group as compared with the control rats' group in all experimental days. The results showed a significant rise in serum total cholesterol concentration within the diabetic group when compared with the control group at day 20 and 60. Meanwhile, a significant increase in serum triglyceride and LDL concentration and a significant decrease in serum HDL concentration within the diabetic group when compared with the control rats group at day 20, 40 and 60. But the serum VLDL concentration depicted a significant increase in the group of diabetic when compared with the control rats group at day 40 and 60. The value of pancreatic tissue protease activity clarified there was a significant decrease of protease action in the group of diabetic rats when compared with the control rats group on both day 20 and day 60. And a significant decrease in amylase activity in the diabetic groups when compared with the group of control rats in both day 20, 40 and day 60. While the results of pancreatic tissue lipase show there were non-significant changes within the diabetics group when compared with the control group. In conclusion, the exocrine pancreatic function is very frequently and severely altered in diabetes mellitus male rats and the metabolic disorder effect of diabetes mellitus was manifested by hyperlipidemic and hypoprotenimic .


Assuntos
Ratos , Ratos , Coleta de Amostras Sanguíneas/veterinária , Diabetes Mellitus Experimental/complicações , Glândulas Exócrinas/enzimologia
10.
Transbound Emerg Dis ; 67(4): 1660-1670, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32027783

RESUMO

BACKGROUND: Following outbreaks in other parts of the Netherlands, the Dutch border region of South Limburg experienced a large-scale outbreak of human Q fever related to a single dairy goat farm in 2009, with surprisingly few cases reported from neighbouring German counties. Late chronic Q fever, with recent spikes of newly detected cases, is an ongoing public health concern in the Netherlands. We aimed to assess the scope and scale of any undetected cross-border transmission to neighbouring German counties, where individuals unknowingly exposed may carry extra risk of overlooked diagnosis. METHODS: (A) Seroprevalence rates in the Dutch area were estimated fitting an exponential gradient to the geographical distribution of notified acute human Q fever cases, using seroprevalence in a sample of farm township inhabitants as baseline. (B) Seroprevalence rates in 122 neighbouring German postcode areas were estimated from a sample of blood donors living in these areas and attending the regional blood donation centre in January/February 2010 (n = 3,460). (C) Using multivariate linear regression, including goat and sheep densities, veterinary Q fever notifications and blood donor sampling densities as covariates, we assessed whether seroprevalence rates across the entire border region were associated with distance from the farm. RESULTS: (A) Seroprevalence in the outbreak farm's township was 16.1%. Overall seroprevalence in the Dutch area was 3.6%. (B) Overall seroprevalence in the German area was 0.9%. Estimated mean seroprevalence rates (per 100,000 population) declined with increasing distance from the outbreak farm (0-19 km = 2,302, 20-39 km = 1,122, 40-59 km = 432 and ≥60 km = 0). Decline was linear in multivariate regression using log-transformed seroprevalence rates (0-19 km = 2.9 [95% confidence interval (CI) = 2.6 to 3.2], 20 to 39 km = 1.9 [95% CI = 1.0 to 2.8], 40-59 km = 0.6 [95% CI = -0.2 to 1.3] and ≥60 km = 0.0 [95% CI = -0.3 to 0.3]). CONCLUSIONS: Our findings were suggestive of widespread cross-border transmission, with thousands of undetected infections, arguing for intensified cross-border collaboration and surveillance and screening of individuals susceptible to chronic Q fever in the affected area.


Assuntos
Doenças Transmissíveis Importadas/transmissão , Coxiella burnetii/imunologia , Surtos de Doenças/estatística & dados numéricos , Febre Q/transmissão , Animais , Anticorpos Antibacterianos/sangue , Coleta de Amostras Sanguíneas/veterinária , Doenças Transmissíveis Importadas/mortalidade , Coxiella burnetii/patogenicidade , Testes Diagnósticos de Rotina , Surtos de Doenças/veterinária , Alemanha/epidemiologia , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Modelos Lineares , Programas de Rastreamento/veterinária , Países Baixos/epidemiologia , Febre Q/mortalidade , Reação em Cadeia da Polimerase em Tempo Real , Estudos Soroepidemiológicos , Ovinos
11.
J Appl Anim Welf Sci ; 23(4): 508-519, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31884823

RESUMO

Information regarding the physiology of African lions is scarce, mainly due to challenges associated with essential routine research procedures. The aim of this experiment was to test the possibility of training six captive lionesses by positive reinforcement conditioning (PRC) to voluntarily allow the collection of vaginal swabs and blood samples. This was done with the final goal of avoiding frequent anesthesia, and potentially stressful management during reproduction research. All lionesses mastered basic clicker and targeting principles within 2 weeks. Routine sampling was possible after 20 weeks of training, enabling the collection of about 750 vaginal swabs and 650 blood samples over 18 months. The animals remained calm and cooperative during all sessions, and demonstrated curiosity in the training. PRC training of captive lionesses proved to be a suitable, minimally invasive method for repeated collection of vaginal swabs and blood. Additionally, PRC may serve as behavioral enrichment for African lions in captive settings. Compared to chemical or physical restraining methods, this noninvasive management approach may reduce distress and physiological negative side effects, thus opening up new avenues for feline research.


Assuntos
Coleta de Amostras Sanguíneas/veterinária , Condicionamento Operante , Leões/fisiologia , Esfregaço Vaginal/veterinária , Animais , Coleta de Amostras Sanguíneas/métodos , Feminino , Reforço Psicológico , Esfregaço Vaginal/métodos
12.
J Vet Intern Med ; 33(6): 2746-2751, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31617618

RESUMO

BACKGROUND: Diseases associated with insulin dysregulation (ID), such as equine metabolic syndrome and pituitary pars intermedia dysfunction, are of interest to practitioners because of their association with laminitis. Accurate insulin concentration assessment is critical in diagnosing and managing these diseases. HYPOTHESIS/OBJECTIVES: To determine the effect of time, temperature, and collection tube type on insulin concentrations in horses at risk of ID. ANIMALS: Eight adult horses with body condition score >6/9. METHODS: In this prospective study, subjects underwent an infeed oral glucose test 2 hours before blood collection. Blood samples were divided into ethylenediaminetetraacetic acid, heparinized, or serum tubes and stored at 4 or 20°C. Tubes were centrifuged and analyzed for insulin by a chemiluminescent assay over 8 days. Changes in insulin concentrations were compared with a linear mixed effects model. RESULTS: An overall effect of time, tube type and temperature was identified (P = .01, P = 0.001, and P = 0.001, respectively). Serum and heparinized samples had similar concentrations for 3 days at 20°C and 8 days at 4°C; however, after 3 days at 20°C, heparinized samples had significantly higher insulin concentrations (P = .004, P = .03, and P = .03 on consecutive days). Ethylenediaminetetraacetic acid samples had significantly lower insulin concentrations regardless of time and temperature (P = .001 for all comparisons). CONCLUSIONS AND CLINICAL IMPORTANCE: These results suggest an ideal protocol to determine insulin concentrations involves using serum or heparinized samples with analysis occurring within 3 days at 20°C or 8 days at 4°C.


Assuntos
Doenças dos Cavalos/sangue , Insulina/sangue , Síndrome Metabólica/veterinária , Doenças da Hipófise/veterinária , Adeno-Hipófise Parte Intermédia , Animais , Coleta de Amostras Sanguíneas/veterinária , Feminino , Cavalos , Insulina/metabolismo , Masculino , Doenças da Hipófise/sangue
13.
Arq. bras. med. vet. zootec. (Online) ; 71(4): 1425-1427, jul.-ago. 2019. tab
Artigo em Inglês | VETINDEX, LILACS | ID: biblio-1038638

RESUMO

Cetose subclínica é uma grande preocupação em rebanhos leiteiros, e seu diagnóstico e prevenção podem ter um grande impacto na saúde animal. Este estudo comparou quatro locais diferentes para a coleta de amostras de sangue (jugular, veias mamárias e coccígeas e ponta da cauda) para medição de ß-hidroxibutirato (BHBA), usando-se um medidor portátil automático. Foram utilizadas seis vacas Holandesas, e a coleta de sangue foi feita no segundo, quinto, 10º, 15º e 21º dias pós-parto. Os resultados do medidor portátil foram semelhantes aos resultados do laboratório e apresentaram uma correlação forte de 0,83. As concentrações séricas de BHBA nas amostras de sangue coletadas na ponta da cauda, na jugular e na coccígea foram semelhantes. No entanto, o sangue retirado da veia mamária tinha uma concentração mais baixa. Portanto, as amostras de sangue para aferição de BHBA podem ser recolhidas nas veias jugular e coccígeas e na ponta da cauda, sendo as duas últimas as opções mais fáceis para monitorar o BHBA em rebanho leiteiro.(AU)


Assuntos
Animais , Feminino , Bovinos , Coleta de Amostras Sanguíneas/métodos , Coleta de Amostras Sanguíneas/veterinária , Cetose/diagnóstico , Cetose/veterinária , Ácido 3-Hidroxibutírico/sangue
14.
Arq. bras. med. vet. zootec. (Online) ; 71(3): 782-790, May-June 2019. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1011331

RESUMO

IIn the last few years, an increasing number of debilitated Magellanic penguins (Spheniscus magellanicus) has been rescued and taken to rehabilitation centers on Brazil's southern coast to be clinically treated and evaluated for re-introduction. This work aims to compare the viability of heparinized plasma with the viability of serum for biochemistry analyses under rehabilitation conditions. Blood sampled from 31 physically healthy rescued penguins was processed into serum/plasma-paired samples and analyzed for 12 biochemical parameters: alanine aminotransferase (ALT), alkaline phosphatase (ALP), aspartate aminotransferase (AST), cholesterol (CHOL), creatine kinase (CK), gamma-glutamyl transpeptidase (GGT), glucose, (GLU) lactate dehydrogenase (LDH), total proteins (TP), triglycerides (TG), urea (UR), and uric acid (UA).The results showed that six paired samples presented visual signs of hemolysis (visual hemolytic score≥1), four of which occurred exclusively in the serum counterpart. Significant differences (P≤ 0.5) between sample types were found for CHOL (3%), GLU (6%) and TG (52%). Only TG was considered clinically relevant (>10%). All mean/median results fell within the available reference intervals by the Association of Zoos and Aquariums (Penguin, 2014). In conclusion, we verified that heparinized plasma is a viable sample for the clinical biochemistry of rescued Magellanic penguins as it yields compatible results with serum, while providing practical benefits. The adoption of this practice favors a faster bird recovery, by minimizing blood sampling volume, and optimizes material resources, allowing use of the same collector tube as for hematology.(AU)


Nos últimos anos, um número crescente de pinguins-de-magalhães (Spheniscus magellanicus) debilitados vem sendo resgatado e encaminhado aos centros de reabilitação do litoral sul do Brasil para cuidados clínicos e posterior avaliação de reintrodução. Este trabalho teve como objetivo comparar a viabilidade do plasma heparinizado com a do soro para análises bioquímicas, em condições de reabilitação. Amostras de sangue de 31 pinguins de resgate fisicamente saudáveis foram processadas em amostras pareadas de soro e plasma heparinizado, e 12 parâmetros bioquímicos foram analisados: alanina aminotransferase (ALT), fosfatase alcalina (ALP), aspartato aminotransferase (AST), colesterol (CHOL), creatina quinase (CK), gamaglutamil transpeptidase (GGT), glicose (GLU), lactato desidrogenase (LDH), proteínas totais (TP), triglicérides (TG), ureia (UR) e ácido úrico (UA). Os resultados mostraram que seis amostras pareadas apresentaram sinais visuais de hemólise (escore hemolítico visual≥1), das quais quatro ocorreram exclusivamente no soro. Observaram-se diferenças significativas (P≤0,5) entre os tipos de amostra em CHOL (3%), GLU (6%) e TG (52%), sendo apenas TG considerado clinicamente relevante (>10%). Todos os resultados de médias e medianas situaram-se dentro dos intervalos de referência disponíveis fornecidos pela Associação de Zoológicos e Aquários (AZA). Como conclusão, verificou-se que o plasma heparinizado é uma amostra viável para a bioquímica clínica de pinguins-de-magalhães de resgate, produzindo resultados compatíveis com os do soro. Além disso, a adoção dessa prática favorece uma recuperação mais rápida dos animais, ao diminuir o volume de sangue amostrado, e otimiza os recursos materiais, ao permitir o aproveitamento do mesmo tubo de colheita de hematologia.(AU)


Assuntos
Animais , Análise Química do Sangue/veterinária , Coleta de Amostras Sanguíneas/veterinária , Spheniscidae/sangue , Plasma , Trabalho de Resgate , Soro
15.
J Virol Methods ; 263: 101-104, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30412721

RESUMO

We recently proposed a new so-called strip-dried format aimed for convenient use of dried biomaterial in diagnostic purposes. In this work, 334 blood samples obtained in strip-dried form were used for bovine leucosis analysis with ELISA and real-time PCR methods. High percentage of seropositive animals (18.3%) let us estimate both indirect (serological) and direct methods applicability for the analysis of strip-dried blood samples and also to compare them (PCR results concurred with ELISA in 93.4% cases). Parallel analysis of native and corresponding strip-dried samples approved the proposed format as a reliable analytical way of sampling being in 100% concordance with conventional serum/whole blood ELISA and PCR analysis. Even distribution of antibodies against bovine leukemia virus along the membrane carrier was demonstrated by square-to-square analyzing of the sample strip (CV not exceeded 7%). Also, strip-dried blood samples showed enhanced stability at elevated temperatures comparing to liquid serum. The proposed strip-blood format is a promising way of sampling, storage and transportation and can find application in veterinary practice for infectious disease monitoring.


Assuntos
Coleta de Amostras Sanguíneas/veterinária , Leucose Enzoótica Bovina/sangue , Leucose Enzoótica Bovina/diagnóstico , Vírus da Leucemia Bovina/isolamento & purificação , Animais , Anticorpos Antivirais/sangue , Coleta de Amostras Sanguíneas/instrumentação , Bovinos , Ensaio de Imunoadsorção Enzimática/veterinária , RNA Viral/sangue , RNA Viral/genética , Reação em Cadeia da Polimerase em Tempo Real/veterinária , Temperatura
16.
Vet Clin Pathol ; 47(4): 556-559, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30325547

RESUMO

BACKGROUND: Whole blood impedance platelet aggregometry (Multiplate-) can be performed with different agonists to evaluate platelet function. Although the manufacturer recommends disposal of stored reagents after 1 month at -20°C or 24 hours at 4°C, reagent integrity after reconstitution under different storage conditions is unknown. If reagent integrity is stable for longer periods, assay costs could decrease dramatically. OBJECTIVES: This study aimed to determine the stability of reconstituted arachidonic acid (AA) and adenosine diphosphate (ADP) platelet agonists stored at -20°C and -80°C for up to 6 months. METHODS: Aliquots of reconstituted AA and ADP were stored at -20°C and -80°C each month for a total of 6 months. Six healthy staff-owned dogs were enrolled in the study. A physical examination, CBC, diagnostic panel, urinalysis, and baseline platelet aggregometry assessment was performed on all of the dogs. Platelet aggregometry was performed using fresh and stored aliquots of AA and ADP reagents on the same day. The area under the curve (AUC) was recorded from each platelet aggregometry analysis. Repeated measures (RM) analysis (one-way ANOVA) was performed and subsequent time points (1, 2, 3, 4, 5, and 6 months) were compared with fresh AUC results. RESULTS: All dogs were clinically healthy, and all diagnostic tests were normal. There were no differences in AUC obtained from fresh samples at any time point or either temperature for AA or ADP. CONCLUSIONS: Whole blood impedance platelet aggregometry reagents, AA and ADP, were stable for up to 6 months when stored at -20°C or -80°C, obviating the need to discard viable reagents, and decreasing assay costs.


Assuntos
Apirase/farmacologia , Ácido Araquidônico/farmacologia , Coleta de Amostras Sanguíneas/veterinária , Agregação Plaquetária , Testes de Função Plaquetária/veterinária , Animais , Plaquetas/efeitos dos fármacos , Coleta de Amostras Sanguíneas/métodos , Cães/sangue , Impedância Elétrica , Agregação Plaquetária/efeitos dos fármacos
17.
Vet Clin Pathol ; 47(3): 415-424, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29989207

RESUMO

BACKGROUND: Point-of-care analyzers can provide a rapid turnaround time for critical blood test results. Agreement between the Enterprise Point-of-Care (EPOC) and bench-top laboratory analyzers is important to determine the clinical reliability of the EPOC. OBJECTIVES: The aim of the study was (1) to evaluate the precision (repeatability) of blood gas values measured by the EPOC and (2) to determine the level of agreement between the EPOC and Nova Critical Care Express (Nova CCX) for the assessment of arterial pH, blood gases, and electrolyte variables in canine and equine blood. METHODS: Arterial blood samples from dogs were analyzed on the EPOC and Nova CCX analyzers to determine precision and agreement of pH, PaCO2 , PaO2 , and HCT. The same analytes plus Na+ , K- , and Cl- were analyzed for agreement using equine blood. Statistical analyses included assessment of precision using the coefficient of variation (CV%), and agreement using the Deming regression, Pearson correlation, and Bland-Altman plots. RESULTS: Both analyzers provided precise results of pH, PaCO2 , PaO2, and HCT, meeting CV% quality requirement values. In both species, Deming regression results were acceptable and correlation values were above 0.93 for arterial pH and blood gases, but lower for sodium and chloride. Bland-Altman plots demonstrated varying degrees of bias, but good agreement between the 2 analyzers was seen when arterial blood gases and electrolytes were measured, except for PaCO2 and Cl-. CONCLUSION: The EPOC analyzer provides consistent, reliable results for canine arterial blood gas values and for equine arterial blood gas and electrolyte values. Cl- results could be acceptable with the application of a correction factor, but the PaCO2 results were more variable.


Assuntos
Autoanálise/veterinária , Gasometria/veterinária , Cães/sangue , Eletrólitos/sangue , Cavalos/sangue , Animais , Autoanálise/instrumentação , Autoanálise/métodos , Gasometria/instrumentação , Gasometria/métodos , Coleta de Amostras Sanguíneas/veterinária , Concentração de Íons de Hidrogênio , Sistemas Automatizados de Assistência Junto ao Leito , Reprodutibilidade dos Testes
18.
J Vet Intern Med ; 32(3): 1051-1059, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29635743

RESUMO

BACKGROUND: Optimal procedure for storage of feline blood is needed. Open-collection systems have been employed in feline medicine, thus limiting the possibility for storage. OBJECTIVES: To evaluate indicators of quality of feline blood stored for 35 days at +4°C in a closed-collection system specifically designed for cats. ANIMALS: Eight healthy adult European domestic shorthair cats with a weight of 5-6.8 kg. METHODS: This is a case series study. A bacteriological test, CBC, blood smear, pH, osmotic fragility, 2,3-diphosphoglycerate (2,3-DPG), and adenosine triphosphate (ATP) measurement were performed weekly on whole blood (WB) units from day 1 to day 35 after donation. The hemolysis index, lactate and potassium concentrations, prothrombin time (PT), activated partial thromboplastin time (aPTT), and fibrinogen were measured on plasma aliquots. RESULTS: One out of eight blood units (BUs) had bacterial growth (Serratia marcescens) at day 35. No significant differences were found regarding CBC, morphology, pH, and osmotic fragility. Despite high inter-individual variability and low starting levels, significant decreases in the mean concentrations of 2,3-DPG (T0 1.99 mmol/g Hb, SD 0.52, T35 1.25 mmol/g Hb, SD 1.43; P = .003) and ATP (T0 1.45 mmol/g Hb, SD 0.71, T35 0.62 mmol/g Hb, SD 0.51; P < .001) were detected during the study, as opposed to an increase in hemolysis (T0 0.11 mmol/L, SD 0.07, T35 0.84 mmol/L, SD 0.19; P < .001), lactate (T0 3.30 mmol/L, SD 0.86, T35 13.36 mmol/L, SD 2.90; P < .001), and potassium (T0 3.10 mmol/L, SD 0.21, T35 4.12 mmol/L, SD 0.35; P < .001) concentrations. CONCLUSIONS AND CLINICAL IMPORTANCE: The commercial BU kit is appropriate for blood collection and conservation of WB in cats. The maintenance of WB quality indicators during storage is essential for future improvements of feline transfusion medicine.


Assuntos
Preservação de Sangue/veterinária , Coleta de Amostras Sanguíneas/veterinária , Gatos/sangue , 2,3-Difosfoglicerato/sangue , Trifosfato de Adenosina/sangue , Animais , Contagem de Células Sanguíneas/veterinária , Preservação de Sangue/métodos , Citratos , Fibrinogênio/análise , Glucose , Hemólise , Concentração de Íons de Hidrogênio , Técnicas In Vitro , Ácido Láctico/sangue , Fragilidade Osmótica , Tempo de Tromboplastina Parcial/veterinária , Potássio/sangue , Tempo de Protrombina/veterinária
19.
Schweiz Arch Tierheilkd ; 160(3): 163-170, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29509139

RESUMO

INTRODUCTION: The aim of this study was to determine reference intervals (RI) for venous blood parameters determined with the RAPIDPoint 500 (RP500) blood gas analyzer using blood gas syringes (BGS) and to determine whether immediate analysis of venous blood collected into lithium heparin (LH) tubes can replace anaerobic blood sampling into BGS. The null hypothesis was that canine venous blood samples collected in BGS and in LH tubes are comparable. Jugular blood was collected from 51 healthy dogs into a BGS and a LH tube. The BGS was immediately analyzed followed by the LH tube. The RI were calculated from BGS results. The BGS and LH tubes results were compared using paired t-test or Wilcoxon matched-pairs signed-rank test and Bland-Altman analysis. To assess clinical relevance, the bias between BGS and LH tubes was compared with the allowable total error (TEa). Values derived from LH tubes showed no significant difference for standard bicarbonate (HCO3std), whole blood base excess (BE B), Na, K, Cl, glucose and hemoglobin (tHb). The pH, partial pressure of carbon dioxide and oxygen, actual bicarbonate, extracellular base excess, ionized Ca, anion gap and lactate were significantly (p.


INTRODUCTION: Le but de la présente étude était de déterminer l'intervalle de référence (RI) de l'analyseur de gaz du sang RAPIDPoint 500 (RP500) pour du sang veineux prélevé dans des seringues pour gaz du sang (BGS) ainsi que de voir si une analyse immédiate du sang collecté dans des tubes à l'héparine de lithium (LH) pouvait remplacer la collecte anaérobe dans des seringues BGS. L'hypothèse était que les échantillons sanguins dans les seringues BGS et dans les tubes LH sont comparables. On a prélevé du sang de la veine jugulaire sur BGS et LH chez 51 chiens en bonne santé, on l'a analysé immédiatement avec l'analyseur RP500 et on a calculé les intervalles de référence pour les résultats des prélèvements sur BGS. Les résultats des prélèvements sur BGS et sur LH ont été comparés au moyen de t-test appariés ou d'un test de Wilcoxon signé ainsi que par une analyse de Bland-Altman. Pour juger de la signification clinique, on a comparé le biais entre BGS et LH avec une erreur globale admissible (TEa). Il n'y avait pas de différence significative entre BGS et LH en ce qui concerne le bicarbonate standard, l'excès basique du sang total, le sodium, le potassium, le glucose et l'hémoglobine. Le pH, les pressions partielles de gaz carbonique et d'oxygène, le bicarbonate effectif, l'excès basique extracellulaire, le calcium ionisé, le trou anionique et le lactate étaient significativement (p.


Assuntos
Gasometria/veterinária , Coleta de Amostras Sanguíneas/veterinária , Cães/sangue , Animais , Análise Química do Sangue/métodos , Análise Química do Sangue/normas , Análise Química do Sangue/veterinária , Gasometria/métodos , Gasometria/normas , Coleta de Amostras Sanguíneas/instrumentação , Feminino , Masculino , Valores de Referência
20.
J Am Vet Med Assoc ; 251(10): 1166-1174, 2017 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-29099261

RESUMO

OBJECTIVE To compare the effect of blood collection by a push-pull technique from an indwelling IV catheter versus direct venipuncture on venous blood gas values before and after administration of alfaxalone or propofol to dogs. DESIGN Prospective randomized clinical study. ANIMALS 30 healthy client-owned dogs that weighed ≥ 10 kg (22 lb) and were anesthetized for elective surgical procedures. PROCEDURES All dogs were premedicated with methadone (0.5 mg/kg [0.2 mg/lb], IM), and 20 to 30 minutes later, anesthesia was induced with either alfaxalone (1 to 3 mg/kg [0.5 to 1.4 mg/lb], IV to effect; n = 15) or propofol (2 to 6 mg/kg [0.9 to 2.7 mg/lb], IV to effect; 15). Immediately prior to premedication and after anesthesia induction, paired blood samples were collected from the cephalic veins; 1 by direct venipuncture and 1 by use of a push-pull technique from a 20-gauge catheter. All blood samples underwent venous blood gas analysis immediately after collection. Results were compared between sample collection techniques before and after anesthesia induction and between anesthesia induction protocols. RESULTS All results were within established reference ranges. For many variables, statistically significant but clinically irrelevant differences were detected between samples collected by direct venipuncture and those collected by the push-pull technique but not between the 2 anesthesia induction protocols. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated the push-pull technique was an acceptable method for collection of blood samples from dogs for venous blood gas analysis that could be used instead of direct venipuncture for patients with patent IV catheters.


Assuntos
Gasometria/veterinária , Coleta de Amostras Sanguíneas/veterinária , Cateteres de Demora/veterinária , Pregnanodionas/farmacologia , Propofol/farmacologia , Anestésicos/administração & dosagem , Anestésicos/farmacologia , Animais , Cães , Hipnóticos e Sedativos/administração & dosagem , Hipnóticos e Sedativos/farmacologia , Pregnanodionas/administração & dosagem , Propofol/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA