Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 118
Filtrar
1.
PET Clin ; 18(3): 337-344, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37030982

RESUMO

Like other major cancers, gastric cancer expresses fibroblast activation protein (FAP) in cancer-associated fibroblasts. Many recent studies have reported the utility and superiority of FAP inhibitor (FAPI)-PET over [18F]fluorodeoxyglucose (FDG)-PET in gastric cancers, from initial staging to recurrence detection. FAPI-PET shows higher accumulation in primary sites and metastatic lesions than does FDG-PET, especially for the detection of peritoneal carcinomatosis. In the case of gastric signet ring cell carcinoma, FAPI-PET showed excellent performance, as uptake is usually weak on FDG-PET in this cohort.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias Gástricas , Neoplasias Gástricas/diagnóstico por imagem , Humanos , Tomografia por Emissão de Pósitrons/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/tendências , Neoplasias Peritoneais/diagnóstico por imagem , Inibidores de Proteases/metabolismo , Fluordesoxiglucose F18/metabolismo , Compostos Radiofarmacêuticos/metabolismo , Compostos Radiofarmacêuticos/normas
2.
Methods Mol Biol ; 2294: 297-323, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33742410

RESUMO

Nuclear medicine radionuclide imaging is a quantitative imaging modality based on radioisotope-labeled tracers which emit radiation in the form of photons used for image reconstruction. Single photon emission computed tomography (SPECT) and positron emission tomography (PET) are the two noninvasive tomographic three-dimensional radionuclide imaging procedures for both clinical and preclinical settings. In this review on nuclear medicine imaging procedures in oncology, a variety of standard SPECT and PET tracers including radioiodine, 18Fluorine fluorodeoxyglucose (18F-FDG), and 68Gallium-labeled small proteins like Prostate Specific Membrane Antigen (PSMA) or somatostatin analogues and their application as targeted molecular imaging probes for improved tumor diagnosis and tumor phenotype characterization are described. Absolute and semiquantitative approaches for calculation of tracer uptake in tumors during the course of disease and during treatment allow further insight into tumor biology, and the combination of SPECT and PET with anatomical imaging procedures like computed tomography (CT) or magnetic resonance imaging (MRI) by hybrid SPECT/CT, PET/CT, and PET/MRI scanners provides both anatomical information and tumor functional characterization within one imaging session. With the recent establishment of novel molecular radiolabeled probes for specific tumor diagnosis, prognosis, and treatment monitoring, nuclear medicine has been able to establish itself as a distinct imaging modality with increased sensitivity and specificity.


Assuntos
Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Animais , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Compostos Radiofarmacêuticos/classificação , Compostos Radiofarmacêuticos/normas , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/normas
3.
Appl Radiat Isot ; 166: 109389, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32882652

RESUMO

Copper oxide nanoparticles (CuO NPs) are needed in various fields, especially in the biomedical field. CuO NPs was obtained from Aspergillus terreus filtrate. CuO NPs structure was confirmed by UV-Vis spectrophotometry, as well as Fourier transform infrared (FT-IR), X-ray diffraction (XRD), scanning electron microscopy (SEM) and transmission electron microscopy (TEM). XRD offers the nanoparticles purity of CuO biosynthesis. CuO NPs are spherical when examined with TEM. The average size of CuO NPs from TEM was 15.75 ± 3.95 nm. New composite of P (AA-AN)-NPs CuO was synthesized by biotechnology and the induced γ-radiation. The distribution coefficient value (Kd) of 47Sc(III) as well as 47Ca(II) ions for the synthetic new composite was determined by batch technique. Radiochemical separation of 47Sc(III) from irradiated calcium target was studied using chromatographic column packed with the new composite material. The recovery yield of 78 ± 1.2% for 47Sc(III) was obtained using 1 M HCl. The quality control tests (chemical, radionuclide and radiochemical purities) of the eluted 47Sc confirmed that it's adequate for nuclear medicine applications.


Assuntos
Cobre/metabolismo , Nanopartículas Metálicas/química , Radioisótopos/isolamento & purificação , Escândio/isolamento & purificação , Aspergillus/metabolismo , Cobre/efeitos da radiação , Humanos , Nanopartículas Metálicas/efeitos da radiação , Nanopartículas Metálicas/ultraestrutura , Nanocompostos/química , Nanocompostos/efeitos da radiação , Nanocompostos/ultraestrutura , Medicina Nuclear , Tamanho da Partícula , Controle de Qualidade , Radioquímica , Radioisótopos/normas , Compostos Radiofarmacêuticos/isolamento & purificação , Compostos Radiofarmacêuticos/normas , Escândio/normas , Nanomedicina Teranóstica/métodos
4.
Biomed Res Int ; 2020: 1572841, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32566657

RESUMO

Whilst radiopharmaceuticals have an important role to play in both imaging and treatment of patients, most notably cancer patients, nuclear medicine and radiopharmacy are currently facing challenges to create innovative new drugs. Traditional radiopharmaceutical manufacture can be considered as either a routine hospital production or a large-scale industrial production. The gap between these two practices has meant that there is an inability to supply innovative radiopharmaceuticals for use at the local level for mono- or multicentric clinical trials with satisfactory quality and safety specifications. This article highlights the regulatory requirements in aseptic pharmaceutical processing and in nuclear medicine to be able to locally produce radiopharmaceuticals. We validate the proof-of-concept for an "in-house" hospital-based radiopharmacy including an on-site cyclotron, that can fulfill the conflicting requirements between radiation safety and aseptic processing. The ARRONAX in-house radiopharmacy is currently able to provide sterile and pyrogenic-free injectable radiopharmaceutical compounds for both industrial and institutional clinical trials.


Assuntos
Medicina Nuclear , Serviço de Farmácia Hospitalar , Compostos Radiofarmacêuticos , Arquitetura de Instituições de Saúde/normas , Humanos , Medicina Nuclear/métodos , Medicina Nuclear/organização & administração , Medicina Nuclear/normas , Serviço de Farmácia Hospitalar/métodos , Serviço de Farmácia Hospitalar/organização & administração , Serviço de Farmácia Hospitalar/normas , Compostos Radiofarmacêuticos/síntese química , Compostos Radiofarmacêuticos/normas
5.
Clin Nucl Med ; 45(5): 341-348, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32049723

RESUMO

PURPOSE: The aim of this study is to investigate and compare the performance of different PET radiopharmaceuticals for the detection of recurrent medullary thyroid carcinoma (MTC) by performing a network meta-analysis (NMA) using direct comparison studies with 2 or more PET radiopharmaceuticals. METHODS: PubMed and EMBASE were searched for the studies evaluating the performance of PET or PET/CT for the detection of recurrent MTC. The NMA was performed for different PET radiopharmaceuticals in both patient- and lesion-based analyses and with a threshold of serum calcitonin or carcinoembryonic antigen (CEA) levels and calcitonin doubling time. The consistency was evaluated by examining the agreement between direct and indirect treatment effects, and publication bias was assessed by funnel plot asymmetry tests. The surface under the cumulative ranking curve values were obtained to calculate the probability of each PET modality being the most effective diagnostic method. RESULTS: A total of 306 patients from 14 direct comparison studies using 5 different PET radiopharmaceuticals (F-FDG, F-DOPA, Ga-somatostatin analogs, 3-O-methyl-6-[F]fluoro-DOPA, and C-methionine) for the detection of recurrent MTC was included. The detection rate of F-DOPA PET was significantly higher than that of FDG PET in both patient- and lesion-based analyses (patient-based analysis: odds ratio, 2.44; 95% confidence interval, 1.4-4.31; lesion-based analysis: odds ratio, 5.74; 95% confidence interval, 1.65-23.4). Among all PET radiopharmaceuticals, F-DOPA showed the highest surface under the cumulative ranking curve value in both patient- and lesion-based analyses regardless of serum calcitonin or CEA levels and calcitonin doubling time. CONCLUSIONS: The results from this NMA indicate that F-DOPA PET clearly showed a best performance for the detection of recurrent MTC in both patient- and lesion-based analyses regardless of serum calcitonin or CEA levels and calcitonin doubling time.


Assuntos
Carcinoma Neuroendócrino/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos/farmacocinética , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/efeitos adversos , Compostos Radiofarmacêuticos/normas
6.
AAPS J ; 22(2): 22, 2020 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-31900688

RESUMO

Immuno-PET is a molecular imaging technique utilizing positron emission tomography (PET) to measure the biodistribution of an antibody species labeled with a radioactive isotope. When applied as a clinical imaging technique, an immuno-PET imaging agent must be manufactured with quality standards appropriate for regulatory approval. This paper describes methods relevant to the chemistry, manufacturing, and controls component of an immuno-PET regulatory filing, such as an investigational new drug application. Namely, the production, quality control, and characterization of the immuno-PET clinical imaging agent, ZED8, an 89Zr-labeled CD8-specific monovalent antibody as well as its desferrioxamine-conjugated precursor, CED8, is described and evaluated. PET imaging data in a human CD8-expressing tumor murine model is presented as a proof of concept that the imaging agent exhibits target specificity and comparable biodistribution across a range of desferrioxamine conjugate loads.


Assuntos
Anticorpos Monoclonais/administração & dosagem , Linfócitos T CD8-Positivos/imunologia , Leucemia de Células T/diagnóstico por imagem , Imagem Molecular , Tomografia por Emissão de Pósitrons , Radioisótopos/administração & dosagem , Compostos Radiofarmacêuticos/administração & dosagem , Zircônio/administração & dosagem , Animais , Anticorpos Monoclonais/química , Linhagem Celular Tumoral , Feminino , Humanos , Leucemia de Células T/imunologia , Camundongos SCID , Valor Preditivo dos Testes , Estudo de Prova de Conceito , Controle de Qualidade , Radioisótopos/química , Radioisótopos/normas , Compostos Radiofarmacêuticos/química , Compostos Radiofarmacêuticos/normas , Zircônio/química , Zircônio/normas
7.
Appl Radiat Isot ; 154: 108852, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31442794

RESUMO

O-(2-[18F]Fluoroethyl)-l-tyrosine ([18F]FET) has become one of the most successful amino acid tracers for human brain tumor imaging with positron emission tomography (PET). Facile fully automated radiosynthesis and quality control (QC) of [18F]FET using our home-built automated multi-purpose 18F-radiosynthesis module are described. [18F]FET was produced in 75-80 min overall synthesis time with 20-25% radiochemical yield decay corrected to end of bombardment (EOB), based on H[18F]F. The radiochemical and enantiomeric purities were >99%, and the molar activity (Am) was 189-411 GBq/µmol at EOB. The [18F]FET dose meets all QC criteria for clinical use, and is suitable for clinical PET study of brain tumor.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Radioisótopos de Flúor , Compostos Radiofarmacêuticos/síntese química , Tirosina/análogos & derivados , Cromatografia Líquida de Alta Pressão , Radioisótopos de Flúor/química , Humanos , Tomografia por Emissão de Pósitrons/métodos , Controle de Qualidade , Compostos Radiofarmacêuticos/química , Compostos Radiofarmacêuticos/normas , Estereoisomerismo , Tirosina/síntese química , Tirosina/química , Tirosina/normas
8.
Eur J Nucl Med Mol Imaging ; 46(10): 2112-2137, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31254038

RESUMO

PURPOSE: Diverse radionuclide imaging techniques are available for the diagnosis, staging, and follow-up of phaeochromocytoma and paraganglioma (PPGL). Beyond their ability to detect and localise the disease, these imaging approaches variably characterise these tumours at the cellular and molecular levels and can guide therapy. Here we present updated guidelines jointly approved by the EANM and SNMMI for assisting nuclear medicine practitioners in not only the selection and performance of currently available single-photon emission computed tomography and positron emission tomography procedures, but also the interpretation and reporting of the results. METHODS: Guidelines from related fields and relevant literature have been considered in consultation with leading experts involved in the management of PPGL. The provided information should be applied according to local laws and regulations as well as the availability of various radiopharmaceuticals. CONCLUSION: Since the European Association of Nuclear Medicine 2012 guidelines, the excellent results obtained with gallium-68 (68Ga)-labelled somatostatin analogues (SSAs) in recent years have simplified the imaging approach for PPGL patients that can also be used for selecting patients for peptide receptor radionuclide therapy as a potential alternative or complement to the traditional theranostic approach with iodine-123 (123I)/iodine-131 (131I)-labelled meta-iodobenzylguanidine. Genomic characterisation of subgroups with differing risk of lesion development and subsequent metastatic spread is refining the use of molecular imaging in the personalised approach to hereditary PPGL patients for detection, staging, and follow-up surveillance.


Assuntos
Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Medicina Nuclear/normas , Feocromocitoma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/normas , Guias de Prática Clínica como Assunto , Neoplasias das Glândulas Suprarrenais/radioterapia , União Europeia , Humanos , Radioisótopos do Iodo/uso terapêutico , Medicina Nuclear/organização & administração , Feocromocitoma/radioterapia , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/farmacocinética , Compostos Radiofarmacêuticos/normas , Compostos Radiofarmacêuticos/uso terapêutico , Sociedades Médicas/normas , Somatostatina/análogos & derivados
9.
Eur J Nucl Med Mol Imaging ; 46(8): 1695-1704, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31098749

RESUMO

The TheraSphere Global Dosimetry Steering Committee was formed in 2017 by BTG International to review existing data and address gaps in knowledge related to dosimetry. This committee is comprised of health care providers with diverse areas of expertise and perspectives on radiation dosimetry. The goal of these recommendations is to optimize glass microspheres radiation therapy for hepatocellular carcinoma while accounting for variables including disease presentation, tumour vascularity, liver function, and curative/palliative intent. The recommendations aim to unify glass microsphere users behind standardized dosimetry methodology that is simple, reproducible and supported by clinical data, with the overarching goal of improving clinical outcomes and advancing the knowledge of dosimetry.


Assuntos
Conferências de Consenso como Assunto , Guias de Prática Clínica como Assunto , Radiometria/normas , Compostos Radiofarmacêuticos/normas , Radioterapia/normas , Radioisótopos de Ítrio/normas , Carcinoma Hepatocelular/radioterapia , Humanos , Neoplasias Hepáticas/radioterapia , Microesferas , Compostos Radiofarmacêuticos/uso terapêutico , Radioterapia/métodos , Dosagem Radioterapêutica , Radioisótopos de Ítrio/uso terapêutico
10.
Appl Radiat Isot ; 145: 251-257, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30686576

RESUMO

At the time of publication, radiopharmaceuticals labelled with thorium-227 are in clinical trials in Europe for the treatment of various types of cancer. In part I of this two-part series the primary standardisation of an aqueous solution of 227Th was reported. In part II, the activity derived from the recommended absolute γ-ray emission intensities have been compared to that from the primary standardisation techniques. This comparison showed a negative bias of 4% in the determined activity per unit mass with an 11% spread in the activities determined for the eight most intense γ-ray emissions (Iγ > 1%) from the 227Th α decay. Using the standardised 227Th, measurements of the characteristic γ-ray emissions from the 223Ra excited states were made using a calibrated HPGe γ-ray spectrometer. This has enabled the absolute intensities of 70 γ ray emissions from the 227Th α-decay to be experimentally determined. A significant improvement over the precision of the recommended normalisation scaling factor has been made, with a value of 12.470 (35) % determined. Typically, the precision of the intensities has been improved by an order of magnitude or greater than current recommended values. The correlation matrices for pairs of the most intense γ-ray emission intensities are presented.


Assuntos
Compostos Radiofarmacêuticos/uso terapêutico , Tório/uso terapêutico , Partículas alfa/uso terapêutico , Calibragem , Raios gama/uso terapêutico , Humanos , Neoplasias/radioterapia , Radioimunoterapia/métodos , Radioimunoterapia/normas , Compostos Radiofarmacêuticos/normas , Rádio (Elemento)/química , Padrões de Referência , Contagem de Cintilação , Espectrometria gama , Tório/normas
11.
Appl Radiat Isot ; 145: 240-250, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30583971

RESUMO

Thorium-227 is a potential therapeutic radionuclide for applications in targeted α-radioimmunotherapy for the treatment of various types of cancer. To provide nuclear medicine departments involved in Phase I clinical trials traceability to the SI unit of radioactivity (Bq), a standardisation of a radiochemically pure 227Th aqueous solution has been performed at the National Physical Laboratory. This was achieved via two primary liquid scintillation (LS) techniques -4π(LS)-γ digital coincidence counting (DCC) and 4π LS counting. These absolute techniques were supported by the indirect determination of the 227Th activity via the measurement of the ingrowth and decay rate of the decay progeny by both ionisations chambers and high purity germanium (HPGe) gamma-ray spectrometry. The results of the primary techniques were found to be consistent, both with each other (zeta score = 1.1) and to the decay progeny ingrowth measurements. An activity per unit mass of 20.726 (51) kBq g-1 was determined for the solution. A procedure has been developed that provided an effective separation of the 227Th from its decay progeny, which was shown by the effective time zero of the 227Th-223Ra nuclear chronometer measured by HPGe gamma-ray spectrometry.


Assuntos
Compostos Radiofarmacêuticos/normas , Tório/normas , Partículas alfa/uso terapêutico , Germânio , Meia-Vida , Humanos , Neoplasias/radioterapia , Radioimunoterapia/métodos , Radioimunoterapia/normas , Radiometria/instrumentação , Compostos Radiofarmacêuticos/análise , Compostos Radiofarmacêuticos/uso terapêutico , Padrões de Referência , Contagem de Cintilação/métodos , Espectrometria gama , Tório/análise , Tório/uso terapêutico
12.
Braz. arch. biol. technol ; 62: e19180545, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1019543

RESUMO

Abstract To present optimized chromatographic systems for radiochemical purity (RCP) evaluation of 99mTc-eluate and 99mTc-radiopharmaceuticals, as well as to assess doses calibrator reliability for routine purposes in hospital radiopharmacies. RCP was determined by different systems and radioactivity was quantified by TLC-scanner, doses calibrator and gamma-counter. Suitable and optimized systems were presented for RCP analyses. No significant differences were observed between radioactivity counting devices and, thus, doses calibrator showed reliability for RCP determination in hospital radiopharmacies.


Assuntos
Radioquímica/métodos , Compostos Radiofarmacêuticos/normas , Cromatografia/métodos , Dosímetros de Radiação
13.
Medicine (Baltimore) ; 97(42): e12817, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30334977

RESUMO

Delayed 18F-2-fluoro-2-deoxy-D-glucose (F-FDG) positron emission tomography (PET) imaging has been associated with improved diagnostic yield in several malignancies; however, data on the use of delayed imaging in patients with hepatocellular carcinoma (HCC) is scarce. This study aimed to examine tumoral and background standardized uptake value (SUV) alterations in dual-phase F-FDG PET/computed tomography (CT) imaging.Fifty-two HCC cases underwent dual-time-point F-FDG PET/CT examination where early and delayed images were obtained. The maximum and mean SUVs (SUVmax and SUVmean) of the tumor were determined for both time points. Similarly, the average SUVmean were also determined for background (liver, soft tissue, and spleen). Changes in tumoral and background SUV between early and delayed images were examined.The mean age was 62.0 ±â€Š12.9 years (range, 20-88 years) and the majority of the patients were men (86.5%). Tumor SUVs, both tumor SUVmean and tumor SUVmax, significantly increased at delayed images when compared to early images. In contrast, the average SUVmean for the liver, soft tissue, and spleen significantly decreased at delayed images.A significant increase in tumor SUV in delayed images in contrast to a significant decrease in background SUVs suggests that delayed images in HCC may contribute to diagnostic performance through a potential increase in the contrast between the tumor and background. However, further studies with larger sample sizes including patients with benign lesions and different grades of the disease are warranted to better elucidate the diagnostic contribution as well as the association of delayed imaging values with prognosis.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Fluordesoxiglucose F18/normas , Neoplasias Hepáticas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/normas , Compostos Radiofarmacêuticos/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons/métodos , Padrões de Referência , Baço/diagnóstico por imagem , Adulto Jovem
14.
Appl Radiat Isot ; 142: 8-11, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30245440

RESUMO

A radio-analytical RP-HPLC method was developed and validated to support production of the P2X7-receptor-targeted [11C]GSK1482160 radiopharmaceutical. Method validation included characterization of retention times, peak shapes, linearity, accuracy, precision, selectivity, limits of detection and quantitation (UV signal), radiochemical stability, as well as analytical method range and robustness. The validated radio-HPLC method is suitable for the definition of [11C]GSK1482160 radiochemical identity, radiochemical purity, as well as molar activity, and is being employed in support of human studies with [11C]GSK1482160.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Ácido Pirrolidonocarboxílico/análise , Ácido Pirrolidonocarboxílico/farmacocinética , Compostos Radiofarmacêuticos/análise , Compostos Radiofarmacêuticos/farmacocinética , Receptores Purinérgicos P2X7/metabolismo , Cromatografia de Fase Reversa/métodos , Estabilidade de Medicamentos , Humanos , Tomografia por Emissão de Pósitrons , Ácido Pirrolidonocarboxílico/normas , Controle de Qualidade , Compostos Radiofarmacêuticos/normas
15.
Appl Radiat Isot ; 140: 294-299, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30098587

RESUMO

In the process of developing [18F]FBEM coupled target peptide, we have instituted a robust automated synthesis of [18F]FBEM, a sulfhydryl (-SH) site specific agent for radiolabeling of peptides and proteins. The radiosynthesis generated 1.67-3.89 GBq (45.1-105.1 mCi, 7.5-18.8% non-decay corrected yield) of [18F]FBEM from 22.2 GBq (600 mCi) of starting [18F]fluoride with molar activity of 31.8 ±â€¯5.3 GBq/µmol (0.86 ±â€¯0.14 mCi/nmol) (n = 3) at the end of synthesis. Radiochemical purity was greater than 98%, and total synthesis time was ~90 min.


Assuntos
Radioisótopos de Flúor/química , Peptídeo 1 Semelhante ao Glucagon/análogos & derivados , Maleimidas/química , Maleimidas/síntese química , Compostos Radiofarmacêuticos/química , Compostos Radiofarmacêuticos/síntese química , Animais , Cromatografia Líquida de Alta Pressão , Peptídeo 1 Semelhante ao Glucagon/síntese química , Peptídeo 1 Semelhante ao Glucagon/química , Peptídeo 1 Semelhante ao Glucagon/normas , Maleimidas/normas , Peptídeos/química , Proteínas/química , Controle de Qualidade , Radioquímica/instrumentação , Radioquímica/métodos , Compostos Radiofarmacêuticos/normas , Reagentes de Sulfidrila/síntese química , Reagentes de Sulfidrila/química
16.
Contrast Media Mol Imaging ; 2018: 6930425, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29977173

RESUMO

High expression of human epidermal growth factor receptor 2 (HER2) in breast and gastroesophageal carcinomas is a predictive biomarker for treatment using HER2-targeted therapeutics (antibodies trastuzumab and pertuzumab, antibody-drug conjugate trastuzumab DM1, and tyrosine kinase inhibitor lapatinib). Radionuclide molecular imaging of HER2 expression might permit stratification of patients for HER2-targeting therapies. In this study, we evaluated a new HER2-imaging probe based on the designed ankyrin repeat protein (DARPin) 9_29. DARPin 9_29 was labeled with iodine-125 by direct radioiodination and with [99mTc]Tc(CO)3 using the C-terminal hexahistidine tag. DARPin 9_29 preserved high specificity and affinity of binding to HER2-expressing cells after labeling. Uptake of [125I]I-DARPin 9_29 and [99mTc]Tc(CO)3-DARPin 9_29 in HER2-positive SKOV-3 xenografts in mice at 6 h after injection was 3.4 ± 0.7 %ID/g and 2.9 ± 0.7 %ID/g, respectively. This was significantly (p < 0.00005) higher than the uptake of the same probes in HER2-negative Ramos lymphoma xenografts, 0.22 ± 0.09 %ID/g and 0.30 ± 0.05 %ID/g, respectively. Retention of [125I]I-DARPin 9_29 in the lung, liver, spleen, and kidneys was appreciably lower compared with [99mTc]Tc(CO)3-DARPin 9_29, which resulted in significantly (p < 0.05) higher tumor-to-organ ratios. The biodistribution data were confirmed by SPECT/CT imaging. In conclusion, radioiodine is a preferable label for DARPin 9_29.


Assuntos
Radioisótopos do Iodo , Imagem Molecular/métodos , Compostos Radiofarmacêuticos/normas , Receptor ErbB-2/análise , Tecnécio , Animais , Repetição de Anquirina , Neoplasias da Mama/química , Neoplasias da Mama/diagnóstico por imagem , Junção Esofagogástrica/patologia , Xenoenxertos , Humanos , Radioisótopos do Iodo/farmacocinética , Camundongos , Imagem Molecular/normas , Neoplasias/química , Neoplasias/diagnóstico por imagem , Compostos Radiofarmacêuticos/farmacocinética , Tecnécio/farmacocinética , Distribuição Tecidual
17.
Contrast Media Mol Imaging ; 2018: 1292746, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30026674

RESUMO

Introductions: [N-methyl-C-11]α-Methylaminoisobutyric acid (MeAIB) is an artificial amino acid radiotracer used for PET study, which is metabolically stable in vivo. In addition, MeAIB is transported by system A neutral amino acid transport, which is observed ubiquitously in all types of mammalian cells. It has already been shown that MeAIB-PET is useful for malignant lymphoma, head and neck cancers, and lung tumors. However, there have been no reports evaluating the usefulness of MeAIB-PET in the diagnosis of brain tumors. The purpose of this study is to investigate the efficacy of system A amino acid transport PET imaging, MeAIB-PET, in clinical brain tumor diagnosis compared to [S-methyl-C-11]-L-methionine (MET)-PET. Methods: Thirty-one consecutive patients (male: 16, female: 15), who were suspected of having brain tumors, received both MeAIB-PET and MET-PET within a 2-week interval. All patients were classified into two groups: Group A as a benign group, which included patients who were diagnosed as low-grade astrocytoma, grade II or less, or other low-grade astrocytoma (n=12) and Group B as a malignant group, which included patients who were diagnosed as anaplastic astrocytoma, glioblastoma multiforme (GBM), or recurrent GBM despite prior surgery or chemoradiotherapy (n=19). PET imaging was performed 20 min after the IV injection of MeAIB and MET, respectively. Semiquantitative analyses of MeAIB and MET uptake using SUVmax and tumor-to-contralateral normal brain tissue (T/N) ratio were evaluated to compare these PET images. ROC analyses for the diagnostic accuracy of MeAIB-PET and MET-PET were also calculated. Results: In MeAIB-PET imaging, the SUVmax was 1.20 ± 1.29 for the benign group and 2.94 ± 1.22 for the malignant group (p < 0.005), and the T/N ratio was 3.77 ± 2.39 for the benign group and 16.83 ± 2.39 for the malignant group (p < 0.001). In MET-PET, the SUVmax was 3.01 ± 0.94 for the benign group and 4.72 ± 1.61 for the malignant group (p < 0.005), and the T/N ratio was 2.64 ± 1.40 for the benign group and 3.21 ± 1.14 for the malignant group (n.s.). For the analysis using the T/N ratio, there was a significant difference between the benign and malignant groups with MeAIB-PET with p < 0.001. The result of ROC analysis using the T/N ratio indicated a better diagnosis accuracy for MeAIB-PET for brain tumors than MET-PET (p < 0.01). Conclusions: MeAIB, a system A amino acid transport-specific radiolabeled agents, could provide better assessments for detecting malignant type brain tumors. In a differential diagnosis between low-grade and high-grade astrocytoma, MeAIB-PET is a useful diagnostic imaging tool, especially in evaluations using the T/N ratio. Clinical trial registration: This trial was registered with UMIN000032498.


Assuntos
Astrocitoma/diagnóstico por imagem , Neoplasias Encefálicas/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/normas , Adolescente , Adulto , Idoso , Sistema A de Transporte de Aminoácidos , Neoplasias Encefálicas/diagnóstico por imagem , Criança , Pré-Escolar , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Metionina/farmacocinética , Metionina/normas , Pessoa de Meia-Idade , Curva ROC , Compostos Radiofarmacêuticos/farmacocinética , Adulto Jovem , beta-Alanina/análogos & derivados , beta-Alanina/farmacocinética , beta-Alanina/normas
18.
Appl Radiat Isot ; 140: 76-82, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29957537

RESUMO

A novel, rapid, and automated loop method for the synthesis of [11C]nicotine was developed and optimized. The method involves, a reaction of the precursor, (+) nornicotine or (-) nornicotine, with a gas-phase produced [11C]CH3I in an 800 µL loop at 75 °C for 5 min followed by a semi-preparatory Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) purification. The optimized synthesis and purification process was complete in < 30 min and produced [11C]nicotine with > 99.9% Radiochemical Purity (RCP), no [11C]CH3I, no (+) nornicotine, 105 mCi/µmole specific activity, 7.0 - 7.2 pH, and 16.6% ethanol. The current method can be optimized, to reduce the ethanol content (<10%), and can be translated to a cGMP production of [11C]nicotine for human clinical trials.


Assuntos
Radioisótopos de Carbono/química , Nicotina/análogos & derivados , Compostos Radiofarmacêuticos/síntese química , Radioisótopos de Carbono/normas , Desenho de Equipamento , Etanol/análise , Humanos , Nicotina/síntese química , Nicotina/química , Controle de Qualidade , Radioquímica/instrumentação , Radioquímica/métodos , Compostos Radiofarmacêuticos/química , Compostos Radiofarmacêuticos/normas
19.
Ann ICRP ; 47(3-4): 142-151, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29714065

RESUMO

The mandate of Committee 3 of the International Commission on Radiological Protection (ICRP) is concerned with the protection of persons and unborn children when ionising radiation is used in medical diagnosis, therapy, and biomedical research. Protection in veterinary medicine has been newly added to the mandate. Committee 3 develops recommendations and guidance in these areas. The most recent documents published by ICRP that relate to radiological protection in medicine are 'Radiological protection in cone beam computed tomography' (ICRP Publication 129) and 'Radiological protection in ion beam radiotherapy' (ICRP Publication 127). A report in cooperation with ICRP Committee 2 entitled 'Radiation dose to patients from radiopharmaceuticals: a compendium of current information related to frequently used substances' (ICRP Publication 128) has also been published. 'Diagnostic reference levels in medical imaging' (ICRP Publication 135), published in 2017, provides specific advice on the setting and use of diagnostic reference levels for diagnostic and interventional radiology, digital imaging, computed tomography, nuclear medicine, paediatrics, and multi-modality procedures. 'Occupational radiological protection in interventional procedures' was published in March 2018 as ICRP Publication 139. A document on radiological protection in therapy with radiopharmaceuticals is likely to be published in 2018. Work is in progress on several other topics, including appropriate use of effective dose in collaboration with the other ICRP committees, guidance for occupational radiological protection in brachytherapy, justification in medical imaging, and radiation doses to patients from radiopharmaceuticals (an update to ICRP Publication 128). Committee 3 is also considering the development of guidance on radiological protection in medicine related to individual radiosusceptibility, in collaboration with ICRP Committee 1.


Assuntos
Exposição à Radiação/prevenção & controle , Proteção Radiológica/normas , Radiação Ionizante , Humanos , Agências Internacionais , Medicina Nuclear/normas , Radiologia Intervencionista/normas , Compostos Radiofarmacêuticos/normas
20.
J Gynecol Obstet Hum Reprod ; 47(5): 205-207, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29510266

RESUMO

Pregnancy-associated breast cancer is rare, but this clinical situation arises in 1/10,000-1/3000 pregnancies. In patients presenting an early-stage breast tumor devoid of clinically pathological lymph node, sentinel lymph node (SLN) biopsy has not yet been validated as a routine procedure for pregnant women due to the lack of data in the literature. The blue dye injection is not recommended because of 2% theoretical risk of anaphylactic shock. Several studies have shown that Tc99m injection at conventional dose between 12.1 and 18.5MBq exposed the fetus to an irradiation between 0.011 and 0.0245mSv much below the 50mSv recommended threshold. As evidenced by lymphoscintigraphy scans, the dose of injected Tc99m is localized at the injection site and in the SLN. According to the literature, the SLN technique does not seem to impact the fetal or obstetrical prognosis. Studies involving larger cohorts are required to confirm these data and to indicate this technique in pregnant women. Considering the benefit for the patient and the low risk incurred on both fetal and obstetrical levels, it appears reasonable to discuss the indication of SLN on a case-by-case basis in multidisciplinary oncologic meetings.


Assuntos
Neoplasias da Mama/diagnóstico , Complicações Neoplásicas na Gravidez/diagnóstico , Cintilografia/normas , Compostos Radiofarmacêuticos/normas , Biópsia de Linfonodo Sentinela/normas , Compostos de Tecnécio/normas , Adulto , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Gravidez , Complicações Neoplásicas na Gravidez/diagnóstico por imagem , Cintilografia/efeitos adversos , Compostos Radiofarmacêuticos/efeitos adversos , Biópsia de Linfonodo Sentinela/efeitos adversos , Compostos de Tecnécio/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA