Resultados 1 - 20 de 1.146
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 25(8): e14451, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38952057

RESUMO

PURPOSE: This study investigated the potential of a commercially available plastic scintillator, the Exradin W2, as a real-time dosimeter for ultra-high-dose-rate (UHDR) electron beams. This work aimed to characterize this system's performance under UHDR conditions and addressed limitations inherent to other conventional dosimetry systems. METHODS AND MATERIALS: We assessed the W2's performance as a UHDR electron dosimeter using a 16 MeV UHDR electron beam from the FLASH research extension (FLEX) system. Additionally, the vendor provided a beta firmware upgrade to better handle the processing of the high signal generated in the UHDR environment. We evaluated the W2 regarding dose-per-pulse, pulse repetition rate, charge versus distance, and pulse linearity. Absorbed dose measurements were compared against those from a plane-parallel ionization chamber, optically stimulated luminescent dosimeters and radiochromic film. RESULTS: We observed that the 1 × 1 mm W2 scintillator with the MAX SD was more suitable for UHDR dosimetry compared to the 1 × 3 mm W2 scintillator, capable of matching film measurements within 2% accuracy for dose-per-pulse up to 3.6 Gy/pulse. The W2 accurately ascertained the inverse square relationship regarding charge versus virtual source distance with R2 of ∼1.00 for all channels. Pulse linearity was accurately measured with the W2, demonstrating a proportional response to the delivered pulse number. There was no discernible impact on the measured charge of the W2 when switching between the available repetition rates of the FLEX system (18-180 pulses/s), solidifying consistent beam output across pulse frequencies. CONCLUSIONS: This study tested a commercial plastic scintillator detector in a UHDR electron beam, paving the way for its potential use as a real-time, patient-specific dosimetry tool for future FLASH radiotherapy treatments. Further research is warranted to test and improve the signal processing of the W2 dosimetry system to accurately measure in UHDR environments using exceedingly high dose-per-pulse and pulse numbers.


Assuntos
Elétrons , Plásticos , Contagem de Cintilação , Plásticos/química , Contagem de Cintilação/instrumentação , Contagem de Cintilação/métodos , Humanos , Radiometria/métodos , Radiometria/instrumentação , Dosagem Radioterapêutica , Imagens de Fantasmas , Aceleradores de Partículas/instrumentação
2.
Phys Med ; 121: 103360, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38692114

RESUMO

This paper reports the development of dosimeters based on plastic scintillating fibers imaged by a charge-coupled device camera, and their performance evaluation through irradiations with the electron Flash research accelerator located at the Centro Pisano Flash Radiotherapy. The dosimeter prototypes were composed of a piece of plastic scintillating fiber optically coupled to a clear optical fiber which transported the scintillation signal to the readout systems (an imaging system and a photodiode). The following properties were tested: linearity, capability to reconstruct the percentage depth dose curve in solid water and to sample in time the single beam pulse. The stem effect contribution was evaluated with three methods, and a proof-of-concept one-dimensional array was developed and tested for online beam profiling. Results show linearity up to 10 Gy per pulse, and good capability to reconstruct both the timing and spatial profiles of the beam, thus suggesting that plastic scintillating fibers may be good candidates for low-energy electron Flash dosimetry.


Assuntos
Elétrons , Plásticos , Dosímetros de Radiação , Dosagem Radioterapêutica , Contagem de Cintilação , Elétrons/uso terapêutico , Contagem de Cintilação/instrumentação , Radiometria/instrumentação
3.
Phys Med Biol ; 69(12)2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38810619

RESUMO

Objective. Optical fiber-based scintillating dosimetry is a recent promising technique owing to the miniature size dosimeter and quality measurement in modern radiation therapy treatment. Despite several advantages, the major issue of using scintillating dosimeters is the Cerenkov effect and predominantly requires extra measurement corrections. Therefore, this work highlighted a novel micro-dosimetry technique to ensure Cerenkov-free measurement in radiation therapy treatment protocol by investigating several dosimetric characteristics.Approach.A micro-dosimetry technique was proposed with the performance evaluation of a novel infrared inorganic scintillator detector (IR-ISD). The detector essentially consists of a micro-scintillating head based on IR-emitting micro-clusters with a sensitive volume of 1.5 × 10-6mm3. The proposed system was evaluated under the 6 MV LINAC beam used in patient treatment. Overall measurements were performed using IBATMwater tank phantoms by following TRS-398 protocol for radiotherapy. Cerenkov measurements were performed for different small fields from 0.5 × 0.5 cm2to 10 × 10 cm2under LINAC. In addition, several dosimetric parameters such as percentage depth dose (PDD), high lateral resolution beam profiling, dose linearity, dose rate linearity, repeatability, reproducibility, and field output factor were investigated to realize the performance of the novel detector.Main results. This study highlighted a complete removal of the Cerenkov effect using a point-like miniature detector, especially for small field radiation therapy treatment. Measurements demonstrated that IR-ISD has acceptable behavior with dose rate variability (maximum standard deviation ∼0.18%) for the dose rate of 20-1000 cGy s-1. An entire linear response (R2= 1) was obtained for the dose delivered within the range of 4-1000 cGy, using a selected field size of 1 × 1 cm2. Perfect repeatability (max 0.06% variation from average) with day-to-day reproducibility (0.10% average variation) was observed. PDD profiles obtained in the water tank present almost identical behavior to the reference dosimeter with a build-up maximum depth dose at 1.5 cm. The small field of 0.5 × 0.5 cm2profiles have been characterized with a high lateral resolution of 100µm.Significance. Unlike recent plastic scintillation detector systems, the proposed micro-dosimetry system in this study requires no Cerenkov corrections and showed efficient performance for several dosimetric parameters. Therefore, it is expected that considering the detector correction factors, the IR-ISD system can be a suitable dose measurement tool, such as in small-field dose measurements, high and low gradient dose verification, and, by extension, in microbeam radiation and FLASH radiation therapy.


Assuntos
Radiometria , Radiometria/instrumentação , Radiometria/métodos , Imagens de Fantasmas , Dosagem Radioterapêutica , Microtecnologia/instrumentação , Humanos , Contagem de Cintilação/instrumentação
4.
Med Phys ; 51(7): 4996-5006, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38748998

RESUMO

BACKGROUND: A dosimeter with high spatial and temporal resolution would be of significant interest for pencil beam scanning (PBS) proton beams' characterization, especially when facing small fields and beams with high temporal dynamics. Optical imaging of scintillators has potential in providing sub-millimeter spatial resolution with pulse-by-pulse basis temporal resolution when the imaging system is capable of operating in synchrony with the beam-producing accelerator. PURPOSE: We demonstrate the feasibility of imaging PBS proton beams as they pass through a plastic scintillator detector to simultaneously obtain multiple beam parameters, including proton range, pencil beam's widths at different depths, spot's size, and spot's position on a pulse-by-pulse basis with sub-millimeter resolution. MATERIALS AND METHODS: A PBS synchrocyclotron was used for proton irradiation. A BC-408 plastic scintillator block with 30 × 30 × 5 cm3 size, and another block with 30 × 30 × 0.5 cm3 size, positioned in an optically sealed housing, were used sequentially to measure the proton range, and spot size/location, respectively. A high-speed complementary metal-oxide-semiconductor (CMOS) camera system synchronized with the accelerator's pulses through a gating module was used for imaging. Scintillation images, captured with the camera directly facing the 5-cm-thick scintillator, were corrected for background (BG), and ionization quenching of the scintillator to obtain the proton range. Spots' position and size were obtained from scintillation images of the 0.5-cm-thick scintillator when a 45° mirror was used to reflect the scintillation light toward the camera. RESULTS: Scintillation images with 0.16 mm/pixel resolution corresponding to all proton pulses were captured. Pulse-by-pulse analysis showed that variations of the range, spots' position, and size were within ± 0.2% standard deviation of their average values. The absolute ranges were within ± 1 mm of their expected values. The average spot-positions were mostly within ± 0.8 mm and spots' sigma agreed within 0.2 mm of the expected values. CONCLUSION: Scintillation-imaging PBS beams with high-spatiotemporal resolution is feasible and may help in efficient and cost-effective acceptance testing and commissioning of existing and even emerging technologies such as FLASH, grid, mini-beams, and so forth.


Assuntos
Contagem de Cintilação , Contagem de Cintilação/instrumentação , Prótons , Ciclotrons , Estudos de Viabilidade , Terapia com Prótons/instrumentação
5.
Med Phys ; 51(7): 5119-5129, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38569159

RESUMO

BACKGROUND: Dosimetry in pre-clinical FLASH studies is essential for understanding the beam delivery conditions that trigger the FLASH effect. Resolving the spatial and temporal characteristics of proton pencil beam scanning (PBS) irradiations with ultra-high dose rates (UHDR) requires a detector with high spatial and temporal resolution. PURPOSE: To implement a novel camera-based system for time-resolved two-dimensional (2D) monitoring and apply it in vivo during pre-clinical proton PBS mouse irradiations. METHODS: Time-resolved 2D beam monitoring was performed with a scintillation imaging system consisting of a 1 mm thick transparent scintillating sheet, imaged by a CMOS camera. The sheet was placed in a water bath perpendicular to a horizontal PBS proton beam axis. The scintillation light was reflected through a system of mirrors and captured by the camera with 500 frames per second (fps) for UHDR and 4 fps for conventional dose rates. The raw images were background subtracted, geometrically transformed, flat field corrected, and spatially filtered. The system was used for 2D spot and field profile measurements and compared to radiochromic films. Furthermore, spot positions were measured for UHDR irradiations. The measured spot positions were compared to the planned positions and the relative instantaneous dose rate to equivalent fiber-coupled point scintillator measurements. For in vivo application, the scintillating sheet was placed 1 cm upstream the right hind leg of non-anaesthetized mice submerged in the water bath. The mouse leg and sheet were both placed in a 5 cm wide spread-out Bragg peak formed from the mono-energetic proton beam by a 2D range modulator. The mouse leg position within the field was identified for both conventional and FLASH irradiations. For the conventional irradiations, the mouse foot position was tracked throughout the beam delivery, which took place through repainting. For FLASH irradiations, the delivered spot positions and relative instantaneous dose rate were measured. RESULTS: The pixel size was 0.1 mm for all measurements. The spot and field profiles measured with the scintillating sheet agreed with radiochromic films within 0.4 mm. The standard deviation between measured and planned spot positions was 0.26 mm and 0.35 mm in the horizontal and vertical direction, respectively. The measured relative instantaneous dose rate showed a linear relation with the fiber-coupled scintillator measurements. For in vivo use, the leg position within the field varied between mice, and leg movement up to 3 mm was detected during the prolonged conventional irradiations. CONCLUSIONS: The scintillation imaging system allowed for monitoring of UHDR proton PBS delivery in vivo with 0.1 mm pixel size and 2 ms temporal resolution. The feasibility of instantaneous dose rate measurements was demonstrated, and the system was used for validation of the mouse leg position within the field.


Assuntos
Terapia com Prótons , Contagem de Cintilação , Animais , Camundongos , Contagem de Cintilação/instrumentação , Terapia com Prótons/instrumentação , Fatores de Tempo , Radiometria/instrumentação , Radiometria/métodos , Dosagem Radioterapêutica , Prótons
6.
Med Phys ; 51(7): 4696-4708, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38569052

RESUMO

BACKGROUND: Gamma camera imaging, including single photon emission computed tomography (SPECT), is crucial for research, diagnostics, and radionuclide therapy. Gamma cameras are predominantly based on arrays of photon multipliers tubes (PMTs) that read out NaI(Tl) scintillation crystals. In this way, standard gamma cameras can localize É£-rays with energies typically ranging from 30 to 360 keV. In the last decade, there has been an increasing interest towards gamma imaging outside this conventional clinical energy range, for example, for theragnostic applications and preclinical multi-isotope positron emission tomography (PET) and PET-SPECT. However, standard gamma cameras are typically equipped with 9.5 mm thick NaI(Tl) crystals which can result in limited sensitivity for these higher energies. PURPOSE: Here we investigate to what extent thicker scintillators can improve the photopeak sensitivity for higher energy isotopes while attempting to maintain spatial resolution. METHODS: Using Monte Carlo simulations, we analyzed multiple PMT-based configurations of gamma detectors with monolithic NaI (Tl) crystals of 20 and 40 mm thickness. Optimized light guide thickness together with 2-inch round, 3-inch round, 60 × 60 mm2 square, and 76 × 76 mm2 square PMTs were tested. For each setup, we assessed photopeak sensitivity, energy resolution, spatial, and depth-of-interaction (DoI) resolution for conventional (140 keV) and high (511 keV) energy É£ using a maximum-likelihood algorithm. These metrics were compared to those of a "standard" 9.5 mm-thick crystal detector with 3-inch round PMTs. RESULTS: Estimated photopeak sensitivities for 511 keV were 27% and 53% for 20 and 40 mm thick scintillators, which is respectively, 2.2 and 4.4 times higher than for 9.5 mm thickness. In most cases, energy resolution benefits from using square PMTs instead of round ones, regardless of their size. Lateral and DoI spatial resolution are best for smaller PMTs (2-inch round and 60 × 60 mm2 square) which outperform the more cost-effective larger PMT setups (3-inch round and 76 × 76 mm2 square), while PMT layout and shape have negligible (< 10%) effect on resolution. Best spatial resolution was obtained with 60 × 60 mm2 PMTs; for 140 keV, lateral resolution was 3.5 mm irrespective of scintillator thickness, improving to 2.8 and 2.9 mm for 511 keV with 20 and 40 mm thick crystals, respectively. Using the 3-inch round PMTs, lateral resolutions of 4.5 and 3.9 mm for 140 keV and of 3.5 and 3.7 mm for 511 keV were obtained with 20 and 40 mm thick crystals respectively, indicating a moderate performance degradation compared to the 3.5 and 2.9 mm resolution obtained by the standard detector for 140 and 511 keV. Additionally, DoI resolution for 511 keV was 7.0 and 5.6 mm with 20 and 40 mm crystals using 60 × 60 mm2 square PMTs, while with 3-inch round PMTs 12.1 and 5.9 mm were obtained. CONCLUSION: Depending on PMT size and shape, the use of thicker scintillator crystals can substantially improve detector sensitivity at high gamma energies, while spatial resolution is slightly improved or mildly degraded compared to standard crystals.


Assuntos
Câmaras gama , Método de Monte Carlo , Iodeto de Sódio , Iodeto de Sódio/química , Luz , Contagem de Cintilação/instrumentação , Fótons
7.
Med Phys ; 51(8): 5754-5763, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38598093

RESUMO

BACKGROUND: While careful planning and pre-treatment checks are performed to ensure patient safety during external beam radiation therapy (EBRT), inevitable daily variations mean that in vivo dosimetry (IVD) is the only way to attain the true delivered dose. Several countries outside the US require daily IVD for quality assurance. However, elsewhere, the manual labor and time considerations of traditional in vivo dosimeters may be preventing frequent use of IVD in the clinic. PURPOSE: This study expands upon previous research using plastic scintillator discs for optical dosimetry for electron therapy treatments. We present the characterization of scintillator discs for in vivo x-ray dosimetry and describe additional considerations due to geometric complexities. METHODS: Plastic scintillator discs were coated with reflective white paint on all sides but the front surface. An anti-reflective, matte coating was applied to the transparent face to minimize specular reflection. A time-gated iCMOS camera imaged the discs under various irradiation conditions. In post-processing, background-subtracted images of the scintillators were fit with Gaussian-convolved ellipses to extract several parameters, including integral output, and observation angle. RESULTS: Dose linearity and x-ray energy independence were observed, consistent with ideal characteristics for a dosimeter. Dose measurements exhibited less than 5% variation for incident beam angles between 0° and 75° at the anterior surface and 0-60 ∘ $^\circ $ at the posterior surface for exit beam dosimetry. Varying the angle between the disc surface and the camera lens did not impact the integral output for the same dose up to 55°. Past this point, up to 75°, there is a sharp falloff in response; however, a correction can be used based on the detected width of the disc. The reproducibility of the integral output for a single disc is 2%, and combined with variations from the gantry angle, we report the accuracy of the proposed scintillator disc dosimeters as ±5.4%. CONCLUSIONS: Plastic scintillator discs have characteristics that are well-suited for in vivo optical dosimetry for x-ray radiotherapy treatments. Unlike typical point dosimeters, there is no inherent readout time delay, and an optical recording of the measurement is saved after treatment for future reference. While several factors influence the integral output for the same dose, they have been quantified here and may be corrected in post-processing.


Assuntos
Fótons , Contagem de Cintilação , Fótons/uso terapêutico , Contagem de Cintilação/instrumentação , Fatores de Tempo , Radiometria/instrumentação , Dosagem Radioterapêutica , Humanos , Radioterapia/métodos , Radioterapia/instrumentação
8.
Med Phys ; 51(6): 4504-4512, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38507253

RESUMO

BACKGROUND: Dosimetry in ultra-high dose rate (UHDR) beamlines is significantly challenged by limitations in real-time monitoring and accurate measurement of beam output, beam parameters, and delivered doses using conventional radiation detectors, which exhibit dependencies in ultra-high dose-rate (UHDR) and high dose-per-pulse (DPP) beamline conditions. PURPOSE: In this study, we characterized the response of the Exradin W2 plastic scintillator (Standard Imaging, Inc.), a water-equivalent detector that provides measurements with a time resolution of 100 Hz, to determine its feasibility for use in UHDR electron beamlines. METHODS: The W2 scintillator was exposed to an UHDR electron beam with different beam parameters by varying the pulse repetition frequency (PRF), pulse width (PW), and pulse amplitude settings of an electron UHDR linear accelerator system. The response of the W2 scintillator was evaluated as a function of the total integrated dose delivered, DPP, and mean and instantaneous dose rate. To account for detector radiation damage, the signal sensitivity (pC/Gy) of the W2 scintillator was measured and tracked as a function of dose history. RESULTS: The W2 scintillator demonstrated mean dose rate independence and linearity as a function of integrated dose and DPP for DPP ≤ 1.5 Gy (R2 > 0.99) and PRF ≤ 90 Hz. At DPP > 1.5 Gy, nonlinear behavior and signal saturation in the blue and green signals as a function of DPP, PRF, and integrated dose became apparent. In the absence of Cerenkov correction, the W2 scintillator exhibited PW dependence, even at DPP values <1.5 Gy, with a difference of up to 31% and 54% in the measured blue and green signal for PWs ranging from 0.5 to 3.6 µs. The change in signal sensitivity of the W2 scintillator as a function of accumulated dose was approximately 4%/kGy and 0.3%/kGy for the measured blue and green signal responses, respectively, as a function of integrated dose history. CONCLUSION: The Exradin W2 scintillator can provide output measurements that are both dose rate independent and linear in response if the DPP is kept ≤1.5 Gy (corresponding to a mean dose rate up to 290 Gy/s in the used system), as long as proper calibration is performed to account for PW and changes in signal sensitivity as a function of accumulated dose. For DPP > 1.5 Gy, the W2 scintillator's response becomes nonlinear, likely due to limitations in the electrometer related to the high signal intensity.


Assuntos
Elétrons , Contagem de Cintilação , Contagem de Cintilação/instrumentação , Dosagem Radioterapêutica , Radiometria/instrumentação , Radioterapia/instrumentação , Aceleradores de Partículas
9.
Med Phys ; 51(7): 5059-5069, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38197459

RESUMO

BACKGROUND: Inorganic scintillation detectors (ISDs) are promising for in vivo dosimetry in brachytherapy (BT). ISDs have fast response, providing time resolved dose rate information, and high sensitivity, attributed to high atomic numbers. However, the conversion of the detector signal to absorbed dose-to-water is highly dependent on the energy spectrum of the incident radiation. This dependence is comprised of absorbed dose energy dependence, obtainable with Monte Carlo (MC) simulation, and the absorbed dose-to-signal conversion efficiency or intrinsic energy dependence requiring measurements. Studies have indicated negligible intrinsic energy dependence of ZnSe:O-based ISDs in Ir-192 BT. A full characterization has not been performed earlier. PURPOSE: This study characterizes the intrinsic energy dependence of ZnSe:O-based ISDs for kV X-ray radiation qualities, with energies relevant for BT. METHODS: Three point-like ISDs made from fiber-coupled cuboid ZnSe:O-based scintillators were calibrated at the Swedish National Metrology Laboratory for ionizing radiation. The calibration was done in terms of air kerma free-in-air, K air ${K}_{{\mathrm{air}}}$ , in 13 X-ray radiation qualities, Q $Q$ , from 25 to 300 kVp (CCRI 25-250 kV and ISO 4037 N-series), and in terms of absorbed dose to water, D w ${D}_{\mathrm{w}}$ , in a Co-60 beam, Q 0 ${Q}_0$ . The mean absorbed dose to the ISDs, relative to K air ${K}_{{\mathrm{air}}}$ and D w ${D}_{\mathrm{w}}$ , were obtained with the MC code TOPAS (Geant4) using X-ray spectra obtained with SpekPy software and laboratory filtration data and a generic Co-60 source. The intrinsic energy dependence was determined as a function of effective photon energy, E e f f ${E}_{eff}$ , (relative to Co-60). The angular dependence of the ISD signal was measured in a 25 kVp (0.20 mm Al HVL) and 135 kVp beam (0.48 mm Cu HVL), by rotating the ISDs 180° around the fiber's longitudinal axis (perpendicular to the beam). A full 360° was not performed due to setup limitations. The impact of detector design was quantified with MC simulation. RESULTS: Above 30 keV E e f f ${E}_{eff}$ the intrinsic energy dependence varied with less than 5 ± 4% from unity for all detectors (with the uncertainty expressed as the mean of all expanded measurement uncertainties for individual E e f f ${E}_{eff}$ above 30 keV, k = 2). Below 30 keV, it decreased with up to 17% and inter-detector variations of 13% were observed, likely due to differences in detector geometry not captured by the simulations using nominal geometry. In the 25 kVp radiation quality, the ISD signal varied with 24% over a ∼45° rotation. For 135 kVp, the corresponding variation was below 3%. Assuming a 0.05 mm thicker layer of reflective paint around the sensitive volume changed the absorbed dose with 6.3% at the lowest E e f f ${E}_{eff}$ , and with less than 2% at higher energies. CONCLUSION: The study suggests that the ISDs have an intrinsic energy dependence relative to Co-60 lower than 5 ± 4% in radiation qualities with E e f f ${E}_{eff}\ $ > 30 keV. Therefore, they could in principle be calibrated in a Co-60 beam quality and transferred to such radiation qualities with correction factors determined only by the absorbed dose energy dependence obtained from MC simulations. This encourages exploration of the ISDs' applications in intensity modulated BT with Yb-169 or other novel intermediate energy isotopes.


Assuntos
Braquiterapia , Método de Monte Carlo , Contagem de Cintilação , Braquiterapia/instrumentação , Braquiterapia/métodos , Contagem de Cintilação/instrumentação , Calibragem
10.
Phys Med Biol ; 69(3)2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38171002

RESUMO

Objective.The goal of this work was to assess the potential use of non-contact scintillator imaging dosimetry for tracking delivery in total body irradiation (TBI).Approach. Studies were conducted to measure the time-gated light signals caused by radiation exposure to scintillators that were placed on tissue. The purpose was to assess efficacy in conditions common for TBI, such as the large source to surface distance (SSD) commonly used, the reduced dose rate, the inclusion of a plexiglass spoiler, angle of incidence and effects of peripheral patient support structures. Dose validation work was performed on phantoms that mimicked human tissue optical properties and body geometry. For this work, 1.5 cm diameter scintillating disks were developed and affixed to phantoms under various conditions. A time-gated camera synchronized to the linac pulses was used for imaging. Scintillation intensity was quantified in post processing and the values verified with simultaneous thermolumiescent dosimeter (TLD) measurements. Mean scintillation values in each region were compared to TLD measurements to produce dose response curves, and scatter effects from the spoiler and patient bed were quantified.Main results.The dose determined by scintillators placed in TBI conditions agreed with TLD dose determinations to within 2.7%, and did so repeatedly within 1.0% standard deviation variance. A linear fit between scintillator signal and TLD dose was achieved with anR2= 0.996 across several body sites. Scatter from the patient bed resulted in a maximum increase of 19% in dose.Significance.This work suggests that non-contact scintillator imaging dosimetry could be used to verify dose in real time to patients undergoing TBI at the prescribed long SSD and low dose rate. It also has shown that patient transport stretchers can significantly influence surface dose by increasing scatter.


Assuntos
Contagem de Cintilação , Irradiação Corporal Total , Humanos , Contagem de Cintilação/métodos , Radiometria/métodos , Dosagem Radioterapêutica , Imagens de Fantasmas , Imagem Óptica/métodos
11.
J Environ Radioact ; 272: 107330, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38000220

RESUMO

Screening of aqueous samples for 3H contamination is required to decide suitability of water intended for human consumption during radiation emergency. BARC, Trombay has recently procured Portable Triathler liquid scintillation counter as a screening tool for on-site response to radiation emergency. For this purpose, parameters like, different available scintillators, scintillator to sample ratio and influence of different capacity scintillation vials were optimized for 3H concentration measurement. The study indicated that for 7 mL vials, the optimized scintillator to sample ratio was 4:1 for Optiphase Hisafe II, Ultima Gold Ultra Low Level Tritium, Aqualight AB and Dioxane based scintillators whereas for Ultima Gold AB and Optiphase Hisafe III scintillators it was 3:1. In case of 20 mL vials, the ratio was optimized to 8:1 for all the above mentioned six scintillators. Additionally, the effect of applying counting efficiency using calibration curves generated using distilled water and that obtained using optimized scintillator to sample ratio in various spiked water samples was also studied. Results in 3H concentration (2000-5700 Bq/mL) indicate about ±10% deviation using both the methods for commercially available scintillators. However, in case of Dioxane based scintillator, the deviation was higher (20%). For analysis of 3H concentration ∼200 Bq/mL using commercially available scintillators results in higher deviation of about 21% due to unreliable quench indicating parameter for count rate less than 4000. The study indicated that calibration curves constructed using optimized parameters are universally applicable for determination of 3H concentration in wide variety of water samples.


Assuntos
Água Potável , Monitoramento de Radiação , Humanos , Trítio , Contagem de Cintilação/métodos , Dioxanos
12.
Med Phys ; 51(2): 1383-1395, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38064645

RESUMO

BACKGROUND: In time-of-flight PET, image quality and accuracy can be enhanced by improving the annihilation photon pair coincidence time resolution, which is the variation in the arrival time difference between the two annihilation photons emitted from each positron decay in the patient. Recent studies suggest direct detection of ionization tracks and their resulting modulation of optical properties, instead of scintillation, can improve the CTR significantly, potentially down to less than 10 ps CTR. However, the arrival times of the 511 keV photons are not predictable, leading to challenges in the spatiotemporal localization characterization of the induced charge carriers in the detector crystal. PURPOSE: To establish an optimized experimental setup for measuring ionization induced modulation of optical properties, it is critical to develop a versatile simulation algorithm that can handle multiple detector material properties and time-resolved charge carrier dynamics. METHODS: We expanded our previous algorithm and simulated ionization tracks, cascade time and induced charge carrier density over time in different materials. For designing a proof-of-concept experiment, we simulated ultrafast electrons and free-electron x-ray photons for timing characterization along with alpha and beta particles for higher spatial localization. RESULTS: With 3 MeV ultrafast electrons, by reducing detector crystal thickness, we can effectively reduce the ionization cascade time to 0.79 ps and deposited energy to 198.5 keV, which is on the order of the desired 511 keV energy. Alpha source simulations produced a cascade time of 2.45 ps and charge carrier density of 6.39 × 1020 cm-3 . Compared to the previous results obtained from 511 keV photon-induced ionization track simulations, the cascade time displayed similar characteristics, while the charge density was found to be higher. These findings suggest that alpha sources have the potential to generate a stronger ionization-induced signal using the modulation of optical properties as the detection mechanism. CONCLUSIONS: This work provides a guideline to understand, design and optimize an experimental platform that is highly sensitive and temporally precise enough to detect single 511 keV photon interactions with a goal to advance CTR for ToF-PET.


Assuntos
Fótons , Tomografia por Emissão de Pósitrons , Humanos , Simulação por Computador , Raios X , Radiografia , Tomografia por Emissão de Pósitrons/métodos , Contagem de Cintilação/métodos
13.
Biomed Phys Eng Express ; 10(1)2023 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-38064731

RESUMO

Organic plastic scintillators are of interest for ionizing radiation dosimetry in megavoltage photon beams because plastic scintillators have a mass density very similar to that of water. This leads to insignificant perturbation of the electron fluence at the point of measurement in a water phantom. This feature is a benefit for dosimetry in strong magnetic fields (e.g., 1.5 T) as found in linacs with magnetic resonance imaging. The objective of this work was to quantify if the light yield per dose for the scintillating fiber BCF-60 material from Saint-Gobain Ceramics and Plastics Inc. is constant regardless of the magnetic flux density. This question is of importance for establishing traceable measurement in MR linacs using this detector type. Experiments were carried out using an accelerator combined with an electromagnet (max 0.7 T). Scintillator probes were read out using chromatic stem-removal techniques based on two optical channels or full spectral information. Reference dosimetry was carried out with PTW31010 and PTW31021 ionization chambers. TOPAS/GEANT4 was used for modelling. The light yield per dose for the BCF-60 was found to be strongly influenced by the magnitude of the magnetic field from about 1 mT to 0.7 T. The light yield per dose increased (1.3 ± 0.2)% (k = 1) from 1 mT to 10 mT and it increased (4.5 ± 0.9)% (k = 1) from 0 T to 0.7 T. Previous studies of the influence of magnetic fields on medical scintillator dosimetry have been unable to clearly identify if observed changes in scintillator response with magnetic field strength were related to changes in dose, stem signal removal, or scintillator light yield. In the current study of BCF-60, we see a clear change in light yield with magnetic field, and none of the other effects.


Assuntos
Radiometria , Contagem de Cintilação , Elétrons , Fótons , Água
14.
J Appl Clin Med Phys ; 24(12): e14150, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37731203

RESUMO

PURPOSE: To evaluate the performance of an electromagnetic (EM)-tracked scintillation dosimeter in detecting source positional errors of IVD in HDR brachytherapy treatment. MATERIALS AND METHODS: Two different scintillator dosimeter prototypes were coupled to 5 degrees-of-freedom (DOF) EM sensors read by an Aurora V3 system. The scintillators used were a 0.3 × 0.4 × 0.4 mm3 ZnSe:O and a BCF-60 plastic scintillator of 0.5 mm diameter and 2.0 mm in length (Saint-Gobain Crystals). The sensors were placed at the dosimeter's tip at 20.0 mm from the scintillator. The EM sampling rate was 40/s while the scintillator signal was sampled at 100 000/s using two photomultiplier tubes from Hamamatsu (series H10722) connected to a data acquisition board. A high-pass filter and a low-pass filter were used to separate the light signal into two different channels. All measurements were performed with an afterloader unit (Flexitron-Elekta AB, Sweden) in full-scattered (TG43) conditions. EM tracking was further used to provide distance/angle-dependent energy correction for the ZnSe:O inorganic scintillator. For the error detection part, lateral shifts of 0.5 to 3 mm were induced by moving the source away from its planned position. Indexer length (longitudinal) errors between 0.5 to 10 mm were also introduced. The measured dose rate difference was converted to a shift distance, with and without using the positional information from the EM sensor. RESULTS: The inorganic scintillator had both a signal-to-noise-ratio (SNR) and signal-to-background-ratio (SBR) close to 70 times higher than those of the plastic scintillator. The mean absolute difference from the dose measurement to the dose calculated with TG-43U1 was 1.5% ±0.7%. The mean absolute error for BCF-60 detector was 1.7% ± 1.2 % $\pm 1.2\%$ when compared to TG-43 calculations formalism. With the inorganic scintillator and EM tracking, a maximum area under the curve (AUC) gain of 24.0% was obtained for a 0.5-mm lateral shift when using the EMT data with the ZnSe:O. Lower AUC gains were obtained for a 3-mm lateral shifts with both scintillators. For the plastic scintillator, the highest gain from using EM tracking information occurred for a 0.5-mm lateral shift at 20 mm from the source. The maximal gain (17.4%) for longitudinal errors was found at the smallest shifts (0.5 mm). CONCLUSIONS: This work demonstrates that integrating EM tracking to in vivo scintillation dosimeters enables the detection of smaller shifts, by decreasing the dosimeter positioning uncertainty. It also serves to perform position-dependent energy correction for the inorganic scintillator,providing better SNR and SBR, allowing detection of errors at greater distances from the source.


Assuntos
Braquiterapia , Dosimetria in Vivo , Humanos , Contagem de Cintilação , Dosímetros de Radiação , Fenômenos Eletromagnéticos , Radiometria , Dosagem Radioterapêutica
15.
Med Phys ; 50(5): 3184-3190, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36852682

RESUMO

BACKGROUND: Recent proposals of high dose rate plans in protontherapy as well as very short proton bunches may pose problems to current beam monitor systems. There is an increasing demand for real-time proton beam monitoring with high temporal resolution, extended dynamic range and radiation hardness. Plastic scintillators coupled to optical fiber sensors have great potential in this context to become a practical solution towards clinical implementation. PURPOSE: In this work, we evaluate the capabilities of a very compact fast plastic scintillator with an optical fiber readout by a SiPM and electronics sensor which has been used to provide information on the time structure at the nanosecond level of a clinical proton beam. MATERIALS AND METHODS: A 3 × 3 × 3 mm3 plastic scintillator (EJ-232Q Eljen Technology) coupled to a 3 × 3 mm2 SiPM (MicroFJ-SMA-30035, Onsemi) has been characterized with a 70 MeV clinical proton beam accelerated in a Proteus One synchrocyclotron. The signal was read out by a high sampling rate oscilloscope (5 GS/s). By exposing the sensor directly to the proton beam, the time beam profile of individual spots was recorded. RESULTS: Measurements of detector signal have been obtained with a time sampling period of 0.8 ns. Proton bunch period (16 ns), spot (10 µs) and interspot (1 ms) time structures could be observed in the time profile of the detector signal amplitude. From this, the RF frequency of the accelerator has been extracted, which is found to be 64 MHz. CONCLUSIONS: The proposed system was able to measure the fine time structure of a clinical proton accelerator online and with ns time resolution.


Assuntos
Terapia com Prótons , Contagem de Cintilação , Fibras Ópticas , Prótons , Plásticos
16.
Appl Radiat Isot ; 191: 110544, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36370472

RESUMO

Liquid scintillation counter (LSC), with its advanced spectrometry capabilities, the Quantulus 1220™, was used to determine gross α-ß measurements in 25 environmental water samples. The determination of gross α-ß emitters with the LSC method requires an accurate pulse shape analyzer (PSA) setting under various quenching conditions. External quenching parameter values were evaluated with americium and strontium standard solutions to look for the optimal PSA value. A PSA calibration curve was obtained and used to measure real samples. To validate a constructed PSA calibration curve, a test was performed using spiked samples with different standard solutions. The results of the same set of 25 water samples were verified by element specific separations followed by α-spectrometry. An acceptable correlation was obtained between the two techniques. In the case of LSC analysis, the results indicate a good PSA optimization. The method was found to be reliable, effective and very suitable for wide range measuring campaigns.


Assuntos
Poluentes Radioativos da Água , Poluentes Radioativos da Água/análise , Contagem de Cintilação/métodos , Partículas alfa , Água
17.
Med Phys ; 49(9): 6209-6220, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35760763

RESUMO

BACKGROUND: With the emergence of more complex and novel proton delivery techniques, there is a need for quality assurance tools with high spatiotemporal resolution to conveniently measure the spatial and temporal properties of the beam. In this context, scintillation-based dosimeters, if synchronized with the radiation beam and corrected for ionization quenching, are appealing. PURPOSE: To develop a synchronized high-speed scintillation imaging system for characterization and verification of the proton therapy beams on a pulse-by-pulse basis. MATERIALS AND METHODS: A 30 cm × 30 cm × 5 cm block of BC-408 plastic scintillator placed in a light-tight housing was irradiated by proton beams generated by a Mevion S250 proton therapy synchrocyclotron. A high-speed camera system, placed perpendicular to the beam direction and facing the scintillator, was synchronized to the accelerator's pulses to capture images. Opening and closing of the camera's shutter was controlled by setting a proper time delay and exposure time, respectively. The scintillation signal was recorded as a set of two-dimensional (2D) images. Empirical correction factors were applied to the images to correct for the nonuniformity of the pixel sensitivity and quenching of the scintillator. Proton range and modulation were obtained from the corrected images. RESULTS: The camera system was able to capture all data on a pulse-by-pulse basis at a rate of ∼504 frames per second. The applied empirical correction method for ionization quenching was effective and the corrected composite image provided a 2D map of dose distribution. The measured range (depth of distal 90%) through scintillation imaging agreed within 1.2 mm with that obtained from ionization chamber measurement. CONCLUSION: A high-speed camera system capable of capturing scintillation signals from individual proton pulses was developed. The scintillation imaging system is promising for rapid proton beam characterization and verification.


Assuntos
Terapia com Prótons , Contagem de Cintilação , Ciclotrons , Método de Monte Carlo , Prótons , Radiometria , Dosagem Radioterapêutica , Contagem de Cintilação/métodos
18.
J Environ Radioact ; 251-252: 106954, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35772320

RESUMO

A novel method for the determination of 99Tc in water samples was developed using stable Re as a chemical yield tracer and TiCl3 as a reducing agent. The influences of several experimental parameters, including TiCl3 concentration, HCl concentration and reaction time, on the reduction of TcO4- and ReO4- as well as Ti(OH)3-TcO2-ReO2 co-precipitation were investigated. Tc(VII) and Re(VII) retained on TK200 resin were effectively eluted by 5 mL of 1 mol/L NH4SCN, which can be directly mixed with the scintillation cocktail for liquid scintillation counting. The results show that the chemical behaviors of Tc and Re are very consistent in the whole procedure. The decontamination factors of potential interferences from ß-emitting nuclides mainly released from nuclear fuel reprocessing plants were also evaluated, and the minimum detectable activity concentration was calculated to be 0.08 Bq/L for 99Tc in water samples with a counting time of 2 h.


Assuntos
Monitoramento de Radiação , Contagem de Cintilação , Titânio , Água
19.
Med Phys ; 49(7): 4715-4730, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35443079

RESUMO

BACKGROUND: There is increased interest in in vivo dosimetry for 192 Ir brachytherapy (BT) treatments using high atomic number (Z) inorganic scintillators. Their high light output enables construction of small detectors with negligible stem effect and simple readout electronics. Experimental determination of absorbed-dose energy dependence of detectors relative to water is prevalent, but it can be prone to high detector positioning uncertainties and does not allow for decoupling of absorbed-dose energy dependence from other factors affecting detector response . PURPOSE: To investigate which measurement conditions and detector properties could affect their absorbed-dose energy dependence in BT in vivo dosimetry. METHODS: We used a general-purpose Monte Carlo (MC) code PENELOPE for the characterization of high-Z inorganic scintillators with the focus on ZnSe ( Z ¯ = 32 $\bar{Z}=32$ ) Z. Two other promising media CsI ( Z ¯ = 54 $\bar{Z}=54$ ) and Al2 O3 ( Z ¯ = 11 $\bar{Z}=11$ ) were included for comparison in selected scenarios. We determined absorbed-dose energy dependence of crystals relative to water under different scatter conditions (calibration phantom 12 × 12 × 30 cm3 , characterization phantoms 20 × 20 × 20 cm3 , 30 × 30 × 30 cm3 , 40 × 40 × 40 cm3 , and patient-like elliptic phantom 40 × 30 × 25 cm3 ). To mimic irradiation conditions during prostate treatments, we evaluated whether the presence of pelvic bones and calcifications affect ZnSe response. ZnSe detector design influence was also investigated. RESULTS: In contrast to low-Z organic and medium-Z inorganic scintillators, ZnSe and CsI media have substantially greater absorbed-dose energy dependence relative to water. The response was phantom-size dependent and changed by 11% between limited- and full-scatter conditions for ZnSe, but not for Al2 O3 . For a given phantom size, a part of the absorbed-dose energy dependence of ZnSe is caused not due to in-phantom scatter but due to source anisotropy. Thus, the absorbed-dose energy dependence of high-Z scintillators is a function of not only the radial distance but also the polar angle. Pelvic bones did not affect ZnSe response, whereas large and intermediate size calcifications reduced it by 9% and 5%, respectively, when placed midway between the source and the detector. CONCLUSIONS: Unlike currently prevalent low- and medium-Z scintillators, high-Z crystals are sensitive to characterization and in vivo measurement conditions. However, good agreement between MC data for ZnSe in the present study and experimental data for ZnSe:O by Jørgensen et al. (2021) suggests that detector signal is proportional to the average absorbed dose to the detector cavity. This enables an easy correction for non-TG43-like scenarios (e.g., patient sizes and calcifications) through MC simulations. Such information should be provided to the clinic by the detector vendors.


Assuntos
Braquiterapia , Dosimetria in Vivo , Radioisótopos de Irídio , Humanos , Radioisótopos de Irídio/uso terapêutico , Método de Monte Carlo , Radiometria , Contagem de Cintilação , Água
20.
Phys Med Biol ; 67(10)2022 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-35483351

RESUMO

Objective.In this study, we propose a novel approach designed to take advantage of the Cerenkov light angular dependency to perform a direct measurement of an external beam irradiation angle.Approach.A Cerenkov probe composed of a 10 mm long filtered sensitive volume of clear PMMA optical fibre was built. Both filtered and raw Cerenkov signals from the transport fibre were collected through a single 1 mm diameter transport fibre. An independent plastic scintillation detector composed of 10 mm BCF12 scintillating fibre was also used for simultaneous dose measurements. A first series of measurements aimed at validating the ability to account for the Cerenkov electron energy spectrum dependency by simultaneously measuring the deposited dose, thus isolating signal variations resulting from the angular dependency. Angular calibration curve for fixed dose irradiations and incident angle measurements using electron and photon beams where also achieved.Main results.The beam nominal energy was found to have a significant impact on the shapes of the angular calibration curves. This can be linked to the electron energy spectrum dependency of the Cerenkov emission cone. Irradiation angle measurements exhibit an absolute mean error of 1.86° and 1.02° at 6 and 18 MV, respectively. Similar results were obtained with electron beams and the absolute mean error reaches 1.97°, 1.66°, 1.45° and 0.95° at 9, 12, 16 and 20 MeV, respectively. Reducing the numerical aperture of the Cerenkov probe leads to an increased angular dependency for the lowest energy while no major changes were observed at higher energy. This allowed irradiation angle measurements at 6 MeV with a mean absolute error of 4.82°.Significance.The detector offers promising perspectives as a potential tool for future quality assurance applications in radiotherapy, especially for stereotactic radiosurgery (SRS), magnetic resonance image-guided radiotherapy (MRgRT) and brachytherapy applications.


Assuntos
Radiometria , Contagem de Cintilação , Calibragem , Elétrons , Fibras Ópticas , Radiometria/métodos , Contagem de Cintilação/métodos