Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
Methods Mol Biol ; 2788: 39-48, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38656507

RESUMO

Plant volatile organic compounds (VOCs) are organic chemicals that plants release as part of their natural biological processes. Various plant tissues produce VOCs, including leaves, stems, flowers, and roots. VOCs are essential in plant communication, defense against pests and pathogens, aroma and flavor, and attracting pollinators. The study of plant volatiles has become an increasingly important area of research in recent years, as scientists have recognized these compounds' important roles in plant physiology. As a result, there has been a growing interest in developing methods for collecting and analyzing plant VOCs. HS-SPME-GC-MS (headspace solid-phase microextraction-gas chromatography-mass spectrometry) is commonly used for plant volatile analysis due to its high sensitivity and selectivity. This chapter describes an efficient method for extracting and identifying volatile compounds by HS-SPME coupled with GC-MS in tomato fruits.


Assuntos
Frutas , Cromatografia Gasosa-Espectrometria de Massas , Solanum lycopersicum , Microextração em Fase Sólida , Compostos Orgânicos Voláteis , Solanum lycopersicum/química , Frutas/química , Compostos Orgânicos Voláteis/isolamento & purificação , Cromatografia Gasosa-Espectrometria de Massas/economia , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microextração em Fase Sólida/economia , Microextração em Fase Sólida/métodos
2.
Sci Rep ; 10(1): 5214, 2020 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-32251326

RESUMO

In the present work, a method based on solvent extraction and gas chromatography-mass spectrometry (GC-MS) has been validated for the determination of 1,4-dioxane in cosmetics. Various solvents including ethyl acetate, hexane, methanol, dichloromethane and acetone have been used for the extraction of 1,4-dioxane, among them the ethyl acetate was found to be the most efficient extracting solvent. This method has offered excellent quality parameters for instance linearity (R2 > 0.9991), limit of detection (LOD, 0.00065-0.00091 µg/mL), limit of quantification (LOQ, 0.00217-0.00304 µg/mL) and, precision intra-day (1.65-2.60%, n = 5) and inter-day (0.16-0.32%, n = 5) in terms of relative standard deviation (RSD%). A total of thirty-nine cosmetic samples of different brands and origin have been studied. Among them, the 1,4-dioxane was found in twenty-three samples (FB1-FB7, MC1-MC4, MC6-MC8, HS3, HS5, BL1-BL3, BL5 and PLD1-PLD3) at the levels between 0.15 µg/mL and 9.92 µg/mL, whereas in sixteen samples (MC5, HS1, HS2, SG1-SG5, BL4 and HP1- HP6) was found to be not detected. The recovery values were achieved between 93% and 99% in both low and high level of spiked samples. In comparison to the traditional analytical techniques, the proposed method was found to be very sensitive and cost-effective for the routine analysis of 1,4-dioxane at low concentration in cosmetics.


Assuntos
Carcinógenos/análise , Cosméticos/análise , Dioxanos/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Acetatos , Carcinógenos/isolamento & purificação , Análise Custo-Benefício , Dioxanos/isolamento & purificação , Cromatografia Gasosa-Espectrometria de Massas/economia , Arábia Saudita , Solventes
3.
Biosci Trends ; 12(2): 201-207, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29760359

RESUMO

An economical, rapid, and sensitive method of gas chromatography-mass spectrometry (GC-MS) was developed and validated to determine the presence of six pesticides (dichlorvos, acetochlor, atrazine, chlorpyrifos, α-endosulfan, and ß-endosulfan) in human plasma. The pesticides were extracted with acetonitrile and concentrated using anhydrous sodium sulfate. Then, the target compounds were analyzed and quantified with GC-MS using borneol as an internal standard. Separation was performed on a HP-5MS capillary column (30 m × 0.25 mm × 0.25 µm) with temperature programming. Detection was accomplished under electro-spray ionization (ESI) in selected ion monitoring (SIM) mode. Under optimized conditions, satisfactory linear ranges of 0.05-10 µg/mL were obtained for all of the analyzed pesticides. The linear correlation coefficients were greater than 0.99. The average recovery was between 86.8 and 106.5%. The inter- and intra-day precision ranged from 1.7-14.5% and 4.2-13.8%, respectively. Dichlorvos was unstable in plasma both at room temperature and when frozen. The other five pesticides were stable after storage at - 20°C for 17 days and two freeze-thaw cycles. Thirty-five plasma samples from 15 patients with acute self-poisoning were analyzed using this method. Dichlorvos was found in 13 plasma samples with a mean concentration of 0.289 µg/mL, and atrazine was found in 6 with a mean concentration of 0.261 µg/mL. Acetochlor was found in one plasma sample (0.153 µg/mL). This method is simple, reliable and cost-effective. It takes little time and does not waste solvents, and it can be used to routinely detect six pesticides in patients with acute poisoning.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Praguicidas/sangue , Intoxicação/sangue , Atrazina/sangue , Atrazina/intoxicação , Diclorvós/sangue , Diclorvós/toxicidade , Cromatografia Gasosa-Espectrometria de Massas/economia , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Humanos , Praguicidas/intoxicação , Intoxicação/diagnóstico , Espectrometria de Massas por Ionização por Electrospray/economia , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas por Ionização por Electrospray/métodos
4.
Food Chem ; 257: 44-52, 2018 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-29622229

RESUMO

A sensitive GC-MS method is reported for the determination of twelve polycyclic aromatic hydrocarbons (PAHs) in baby food. The sample preparation involves QuEChERS extraction combined with low-density solvent dispersive liquid-liquid microextraction (LDS-DLLME) and ultra-low temperature (-80 °C). Plackett-Burman screening design was employed to identify the main sample preparation variables that affect the extraction efficiency, such as the volume of toluene used in LDS-DLLME. The suitability of proposed method was verified by analytical selectivity, linearity in solvent and matrix-matched calibration curves and adequate recoveries (72-112%) and precision (RSD values ≤11%), under repeatability and within-laboratory reproducibility conditions. High analytical sensitivity was achieved for the monitoring of PAHs at the strict limit of 1 µg kg-1 fixed by the European Commission for baby foods. The validated method was applied to thirty-two commercial baby food samples, and the investigated PAHs were not detected in any sample.


Assuntos
Análise de Alimentos/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Alimentos Infantis/análise , Microextração em Fase Líquida/métodos , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Solventes/química , Métodos Analíticos de Preparação de Amostras , Análise de Alimentos/economia , Contaminação de Alimentos/análise , Cromatografia Gasosa-Espectrometria de Massas/economia , Hidrocarbonetos Policíclicos Aromáticos/química , Reprodutibilidade dos Testes
5.
Anal Bioanal Chem ; 410(22): 5491-5506, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29138882

RESUMO

Nowadays, the control of pesticide residues in food is well established. The capacity of triple quadrupole technology to satisfy the current food regulations has been demonstrated. However, the permanent high demand of consumers for more sensitive and faster testing is driving the development of improved analytical methodologies that increase the performances of sensitivity and robustness and reduce the analysis time. In this work, the feasibility of decreasing the run time to 12.4 min by modifying the oven temperature program, for a multiresidue method covering 203 pesticides, was evaluated. Satisfactory sensitivity results were achieved by reaching a limit of quantitation of 2 µg kg-1 for a great variety of fruits and vegetables. The validated method based on updated GC-QqQ-MS/MS has confirmed the abovementioned challenges with adequate robustness by its application to routine analyses for 69 real samples. The proposed method can represent great benefit for laboratories as it allows increasing samples throughput. It is also very useful for risk assessment studies, where the needs of low reporting limits and very wide analytical scope are necessary.


Assuntos
Contaminação de Alimentos/análise , Frutas/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Resíduos de Praguicidas/análise , Verduras/química , Cromatografia Gasosa-Espectrometria de Massas/economia , Análise de Perigos e Pontos Críticos de Controle/métodos , Limite de Detecção , Praguicidas/análise , Espectrometria de Massas em Tandem/economia , Espectrometria de Massas em Tandem/métodos , Temperatura , Fatores de Tempo
6.
Anal Bioanal Chem ; 409(23): 5555-5567, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28717897

RESUMO

The quantification of short-chain and medium-chain fatty acids is becoming more and more relevant in fecal and plasma samples due to their biological impact, which has been associated with colon rectal cancer and fiber consumption. For these reasons, a fast, cost-effective, and reproducible analytical method is highly required. In this research, a gas chromatography-mass spectrometry method based on full scan and multiple reaction monitoring (MRM) acquisition modes were optimized and validated for the analysis of short-chain and medium-chain fatty acids in three biological samples: human fecal water, fecal fermentation supernatants, and human plasma. Several extraction solvents (acidified water, diethyl ether, dichloromethane, ethyl acetate, and methyl tert-butyl ether (MTBE) were further evaluated, demonstrating that the latter was clearly the most suitable solvent with recoveries from 75.4 to 124.4% and coefficient of variations lower than 20%. The applicability of the GC-MS method was tested, for instance, acetic acid was quantified by using samples of plasma and feces from healthy donors at mean values of 66.9 µM and 24.5 mM, respectively. The optimized protocol could successfully find applications within multi-compartment human studies. In parallel, a second pilot experiment on fecal fermentation supernatants indicated that the proposed protocol is suitable to follow the formation of SCFAs during in vitro fermentation by the human gut microbiota. In summary, the present work provided an improved GC-MS method for precise and accurate quantification of SCFAs and MCFAs in human feces and plasma.


Assuntos
Líquidos Corporais/química , Ácidos Graxos/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Análise Custo-Benefício , Fermentação , Cromatografia Gasosa-Espectrometria de Massas/economia , Humanos
7.
Rapid Commun Mass Spectrom ; 31(19): 1573-1581, 2017 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-28708331

RESUMO

RATIONALE: Transfluthrin is a relatively non-toxic rapid-acting synthetic pyrethroid insecticide. It is widely used in household and hygiene products. A sensitive and accurate bioanalytical method is required for quantification of its concentration in plasma and its potential target organ, the brain for studies to assess its health effects and toxicokinetics in mammals. METHODS: The samples were prepared by liquid-liquid extraction. Gas chromatography mass spectrometry (GC/MS) analysis was performed for the determination of transfluthrin in biological samples with an overall method run time of 15 min. Transfluthrin was quantified using selected-ion monitoring (SIM) in the negative chemical ionization (NCI) mode. Chromatographic separation was achieved using a Zebron® ZB5-MS GC column operating with 1 mL/min constant flow helium. Cis-Permethrin was used as the internal standard. RESULTS: The method was validated to be precise and accurate within the linear range of 1.0-400.0 ng/mL in plasma and 4.0-400.0 ng/mL in brain homogenate, based on a 100 µL sample volume for both matrices. This method was applied to samples following administration of a 10 mg/kg oral dose to male adult rats. The plasma concentrations were observed to be 11.70 ± 5.69 ng/mL and brain concentrations 12.09 ± 3.15 ng/g when measured 2 h post-dose. CONCLUSIONS: A rapid GC/NCI-MS method was demonstrated to be sensitive, specific, precise and accurate for the quantification of transfluthrin in rat plasma and brain. The optimized method was successfully used to quantify the rat plasma and brain concentrations of transfluthrin 2 h after the oral dosing of Sprague-Dawley rats.


Assuntos
Química Encefálica , Ciclopropanos/análise , Ciclopropanos/sangue , Fluorbenzenos/análise , Fluorbenzenos/sangue , Cromatografia Gasosa-Espectrometria de Massas/métodos , Inseticidas/análise , Inseticidas/sangue , Administração Oral , Animais , Ciclopropanos/administração & dosagem , Fluorbenzenos/administração & dosagem , Cromatografia Gasosa-Espectrometria de Massas/economia , Inseticidas/administração & dosagem , Extração Líquido-Líquido/economia , Extração Líquido-Líquido/métodos , Masculino , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes
8.
Artigo em Inglês | MEDLINE | ID: mdl-27856194

RESUMO

Our objective was to develop a quick and simplified method for the determination of ß-Hydroxy-ß-methylbutyrate (HMB) and ɑ-ketoisocaproic acid (KIC) concentrations and enrichments by GC/MS/MS to determine the turnover rate of HMB in humans. In experiment 1, we provided a pulse of L-[5,5,5-2H3]leucine to younger adults in the postabsorptive state then collected blood samples over a 4h time period. In experiment 2, we provided a pulse of [3,4,methyl-13C3]HMB to older adults in the postabsorptive state then collected blood samples over a 3h time period. Plasma concentrations of KIC and HMB and MPE of KIC and HMB were determined by GC/MS/MS. Plasma enrichment of leucine was determined by LC/MS/MS. To determine plasma enrichment of [5,5,5-2H3]HMB and [3,4,methyl-13C3]HMB, samples were derivatized using pentafluorobenzyl bromide and analyzed using chemical ionization mode. The final methods used included multiple reaction monitoring of transitions 117.3>59.3 for M+0 and 120.3>59.3 for M+3. In experiment 1, peak MPE of Leu peaked at 9.76% generating a peak MPE of KIC at 2.67% and a peak HMB MPE of 0.3%. In experiment 2, the rate of appearance for HMB was 0.66µmol/kg ffm/h. We calculated that production of HMB in humans accounts for 0.66% of total leucine turnover.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Cetoácidos/sangue , Espectrometria de Massas em Tandem/métodos , Valeratos/sangue , Adulto , Idoso , Cromatografia Gasosa-Espectrometria de Massas/economia , Humanos , Limite de Detecção , Pessoa de Meia-Idade , Espectrometria de Massas em Tandem/economia , Adulto Jovem
9.
Artigo em Inglês | MEDLINE | ID: mdl-27880928

RESUMO

Cellular fatty acid (FA) profiles have been acknowledged as biomarkers in various human diseases. Nevertheless, common FA analysis by gas chromatography mass spectrometry (GC-MS) requires long analysis time. Hence, there is a need for feasible methods for high throughput analysis in clinical studies. FA was extracted from red blood cells (RBC) and derivatized to fatty acid methyl esters (FAME). A method using gas chromatography tandem mass spectrometry (GC-MS/MS) with ammonia-induced chemical ionization (CI) was developed for the analysis of FA profiles in human RBC. We compared this method with classical single GC-MS using electron impact ionization (EI). The FA profiles of 703 RBC samples were determined by GC-MS/MS. In contrast to EI ammonia-induced CI resulted in adequate amounts of molecular ions for further fragmentation of FAME. Specific fragments for confident quantification and fragmentation were determined for 45 FA. The GC-MS/MS method has a total run time of 9min compared to typical analysis times of up to 60min in conventional GC-MS. Intra and inter assay variations were <10% for all FA analyzed. Analysis of RBC FA composition revealed an age-dependent increase of the omega-3 eicosapentaenoic and docosahexaenoic acid, and a decline of the omega-6 linoleic acid with a corresponding rise of the omega-3 index. The combination of ammonia-induced CI and tandem mass spectrometry after GC separation allows for high-throughput, robust and confident analysis of FA profiles in the clinical laboratory.


Assuntos
Eritrócitos/química , Ácidos Graxos/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Adolescente , Adulto , Criança , Ácidos Graxos Ômega-3/análise , Feminino , Cromatografia Gasosa-Espectrometria de Massas/economia , Humanos , Limite de Detecção , Masculino , Pessoa de Meia-Idade , Espectrometria de Massas em Tandem/economia , Espectrometria de Massas em Tandem/métodos , Adulto Jovem
10.
J Biosci Bioeng ; 122(3): 370-7, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26979344

RESUMO

Endocrine disruptors (ED) are chemicals that affect various aspects of the endocrine system, often leading to the inhibition of steroidogenesis. Current chemical safety policies that restrict human exposure to such chemicals describe often time-consuming and costly methods for the evaluation of ED effects. We aimed to develop an effective tool for accurate phenotypic chemical toxicology studies. We developed an in vitro ED evaluation system using gas chromatography/mass spectrometry (GC/MS/MS) methods for metabolomic analysis of multi-marker profiles. Accounting for sample preparation and GC/MS/MS conditions, we established a screening method that allowed the simultaneous analysis of 17 steroids with good reproducibility and a linear calibration curve. Moreover, we applied the developed system to H295R human adrenocortical cells exposed to forskolin and prochloraz in accordance with the Organization for Economic Cooperation and Development (OECD) guidelines and observed dose-dependent variations in steroid profiles. While the OECD guidelines include only testosterone and 17ß-estradiol, our system enabled a comprehensive and highly sensitive analysis of steroid profile alteration due to ED exposure. The application of our ED evaluation screen could be economical and provide novel insights into the hazards of ED exposure to the endocrine system.


Assuntos
Disruptores Endócrinos/toxicidade , Metabolômica/métodos , Esteroides/análise , Córtex Suprarrenal/citologia , Córtex Suprarrenal/efeitos dos fármacos , Córtex Suprarrenal/metabolismo , Calibragem , Linhagem Celular , Colforsina/farmacologia , Relação Dose-Resposta a Droga , Disruptores Endócrinos/administração & dosagem , Estradiol/análise , Estradiol/metabolismo , Cromatografia Gasosa-Espectrometria de Massas/economia , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Imidazóis/farmacologia , Técnicas In Vitro , Metabolômica/economia , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/economia , Espectrometria de Massas em Tandem/métodos , Testosterona/análise , Testosterona/metabolismo
11.
Methods Mol Biol ; 1383: 125-31, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26660182

RESUMO

Drug screening is an essential component of clinical toxicology laboratory service. Some laboratories use only automated chemistry analyzers for limited screening of drugs of abuse and few other drugs. Other laboratories use a combination of various techniques such as immunoassays, colorimetric tests, and mass spectrometry to provide more detailed comprehensive drug screening. Mass spectrometry, gas or liquid, can screen for hundreds of drugs and is often considered the gold standard for comprehensive drug screening. We describe an efficient and rapid gas chromatography/mass spectrometry (GC/MS) method for comprehensive drug screening in urine which utilizes a liquid-liquid extraction, sample concentration, and analysis by GC/MS.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Detecção do Abuso de Substâncias/métodos , Urinálise/métodos , Cromatografia Gasosa-Espectrometria de Massas/economia , Humanos , Extração Líquido-Líquido/economia , Extração Líquido-Líquido/métodos , Detecção do Abuso de Substâncias/economia , Fatores de Tempo , Urinálise/economia
12.
J Biosci Bioeng ; 120(5): 555-61, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25912451

RESUMO

Development of authenticity screening for Asian palm civet coffee, the world-renowned priciest coffee, was previously reported using metabolite profiling through gas chromatography/mass spectrometry (GC/MS). However, a major drawback of this approach is the high cost of the instrument and maintenance. Therefore, an alternative method is needed for quality and authenticity evaluation of civet coffee. A rapid, reliable and cost-effective analysis employing a universal detector, GC coupled with flame ionization detector (FID), and metabolite fingerprinting has been established for discrimination analysis of 37 commercial and non-commercial coffee beans extracts. gas chromatography/flame ionization detector (GC/FID) provided higher sensitivity over a similar range of detected compounds than GC/MS. In combination with multivariate analysis, GC/FID could successfully reproduce quality prediction from GC/MS for differentiation of commercial civet coffee, regular coffee and coffee blend with 50 wt % civet coffee content without prior metabolite details. Our study demonstrated that GC/FID-based metabolite fingerprinting can be effectively actualized as an alternative method for coffee authenticity screening in industries.


Assuntos
Café/química , Café/metabolismo , Ionização de Chama/métodos , Metaboloma , Viverridae , Animais , Café/normas , Análise Discriminante , Indústria Alimentícia/métodos , Cromatografia Gasosa-Espectrometria de Massas/economia , Análise Multivariada , Padrões de Referência
13.
Clin Biochem ; 48(3): 189-91, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25500419

RESUMO

OBJECTIVES: A simple, cost-effective, and fast gas chromatography method with mass spectrometry detection (GC-MS) for simultaneous measurement of ethylene glycol, 1,2-propylene glycol and glycolic acid was developed and validated for clinical toxicology purposes. DESIGN AND METHODS: Successful derivatization of glycolic acid with isobutyl chloroformate was achieved directly in serum/urine while glycols are simultaneously derivatized by phenylboronic acid. The entire sample preparation procedure is completed within 10 min. RESULTS: The assay was proved to be quadratic in the range of 50 to 5000 mgL(-1) with adequate accuracy (96.3-105.8%) and precision (CV ≤ 8.9%). CONCLUSION: The method was successfully applied to quantify the selected compounds in serum of patients from emergency units and the results correlated well with parallel GC-FID measurements (R(2) 0.9933 for ethylene glycol and 0.9943 for glycolic acid).


Assuntos
Análise Custo-Benefício , Etilenoglicol/sangue , Etilenoglicol/urina , Cromatografia Gasosa-Espectrometria de Massas/economia , Cromatografia Gasosa-Espectrometria de Massas/métodos , Glicolatos/sangue , Glicolatos/urina , Emergências , Humanos , Fatores de Tempo , Toxicologia
14.
J Chromatogr A ; 1361: 77-87, 2014 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-25152493

RESUMO

Based on a modified quick, easy, cheap, effective, rugged and safe (QuEChERS) sample preparation method with Fe3O4 magnetic nanoparticles (MNPs) as the adsorbing material and gas chromatography-tandem mass spectrometry (GC-MS/MS) determination in multiple reaction monitoring (MRM) mode, we established a new method for the determination of multiple pesticides in vegetables and fruits. It was determined that bare MNPs have excellent function as adsorbent when purified, and it is better to be separated from the extract. The amount of MNPs influenced the clean-up performance and recoveries. To achieve the optimum performance of modified QuEChERS towards the target analytes, several parameters including the amount of the adsorbents and purification time were investigated. Under the optimum conditions, recoveries were evaluated in four representative matrices (tomato, cucumber, orange and apple) with the spiked concentrations of 10 µg kg(-1), 50 µg kg(-1)and 200 µg kg(-1) in all cases. The results showed that the recovery of 101 pesticides ranged between 71.5 and 111.7%, and the relative standard deviation was less than 10.5%. The optimum clean-up system improved the purification efficiency and simultaneously obtained satisfactory recoveries of multiple pesticides, including planar-ring pesticides. In short, the modified QuEChERS method in addition to MNPs used for removing impurities improved the speed of sample pre-treatment and exhibited an enhanced performance and purifying effect.


Assuntos
Compostos Férricos/química , Frutas/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Nanopartículas de Magnetita/química , Resíduos de Praguicidas/análise , Espectrometria de Massas em Tandem/métodos , Verduras/genética , Cromatografia Gasosa-Espectrometria de Massas/economia , Nanopartículas de Magnetita/ultraestrutura , Microscopia Eletrônica de Transmissão , Espectrometria de Massas em Tandem/economia , Fatores de Tempo , Verduras/química
15.
Artigo em Inglês | MEDLINE | ID: mdl-24321757

RESUMO

A novel analytical approach based on molecularly imprinted solid phase extraction (MISPE) coupled with dispersive liquid-liquid microextraction (DLLME), and injector port silylation (IPS) has been developed for the selective preconcentration, derivatization and analysis of 3-phenoxybenzoic acid (3-PBA) using gas chromatography-tandem mass spectrometry (GC-MS/MS) in complex biological samples such as rat blood and liver. Factors affecting the synthesis of MIP were evaluated and the best monomer and cross-linker were selected based on binding affinity studies. Various parameters of MISPE, DLLME and IPS were optimized for the selective preconcentration and derivatization of 3-PBA. The developed method offers a good linearity over the calibration range of 0.02-2.5ngmg(-1) and 7.5-2000ngmL(-1) for liver and blood respectively. Under optimized conditions, the recovery of 3-PBA in liver and blood samples were found to be in the range of 83-91%. The detection limit was found to be 0.0045ngmg(-1) and 1.82ngmL(-1) in liver and blood respectively. SRM transition of 271→227 and 271→197 has been selected as quantifier and qualifier transition for 3-PBA derivative. Intra and inter-day precision for five replicates in a day and for five, successive days was found to be less than 8%. The method developed was successfully applied to real samples, i.e. rat blood and tissue for quantitative evaluation of 3-PBA. The analytical approach developed is rapid, economic, simple, eco-friendly and possess immense utility for the analysis of analytes with polar functional groups in complex biological samples by GC-MS/MS.


Assuntos
Benzoatos/análise , Benzoatos/sangue , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microextração em Fase Líquida/métodos , Fígado/química , Impressão Molecular , Animais , Cromatografia Gasosa-Espectrometria de Massas/economia , Limite de Detecção , Microextração em Fase Líquida/economia , Ratos , Ratos Wistar , Espectrometria de Massas em Tandem/economia , Espectrometria de Massas em Tandem/métodos
16.
J Chromatogr B Analyt Technol Biomed Life Sci ; 945-946: 217-24, 2014 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-24361859

RESUMO

A fully automated and robust method featuring on-line solid-phase extraction (SPE) and large volume injection (LVI) gas chromatographic (GC) high resolution mass spectrometry (HRMS) is used to determine polychlorinated biphenyls (PCBs) and organochlorine pesticides, such as penta- and hexachlorobenzene (PeCBz, HxCBz), hexachlorocyclohexane isomers (HCH) and 4,4'-dichlorodiphenyldichloroethene (a metabolite of dichlorodiphenyltrichloroethane (DDT)), with only 200µl of human blood, serum or plasma. After spiking the sample with (13)C-labeled internal standards and precipitating the proteins, the sample is passed through a 10mm×2.0mm ID SPE cartridge filled with C18 material that adsorbs the analytes. After washing and drying, the cartridge is extracted with hexane/dodecane (99/1, v/v); the extract is directly injected into a LVI where GC/HRMS analysis follows. The fully automated system utilizes a robotic autosampler and a modular SPE system including two high-pressure syringe pumps, an automatic SPE cartridge exchanger unit and 6 switchable valves. All sample preparation steps are performed within 20min during the GC run of a previous sample, limiting the throughput with only the GC runtime. The contents are quantified using the isotope dilution method. Due to laboratory air contamination problems, we achieved LOQs of 0.017 (PeCBz), 0.009 (HxCBz), 0.007 (HCH), 0.016 (DDE), while for the six indicator PCBs, we achieved values of 0.030 (PCB-28), 0.044 (PCB-52), 0.024 (PCB-101), 0.009 (PCB-138), 0.015 (PCB-153) and 0.008 (PCB-180)µg/l serum. Under clean laboratory air conditions, these values may be improved. This method is recommended when high throughput is desirable and/or only small amounts of material are available, such as during studies involving children.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Ensaios de Triagem em Larga Escala/instrumentação , Hidrocarbonetos Clorados/sangue , Praguicidas/sangue , Bifenilos Policlorados/sangue , Extração em Fase Sólida/instrumentação , Desenho de Equipamento , Cromatografia Gasosa-Espectrometria de Massas/economia , Ensaios de Triagem em Larga Escala/economia , Humanos , Limite de Detecção , Extração em Fase Sólida/economia
17.
Rapid Commun Mass Spectrom ; 27(21): 2374-82, 2013 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-24097393

RESUMO

RATIONALE: The phthiocerol dimycocerosates (PDIMs) are certain stable and hydrophobic waxes found in the cell membrane of Mycobacterium tuberculosis, bacteria that cause an infectious disease of growing concern worldwide. Previous studies report the analysis of derivatives of the hydrolysed PDIMs from biological samples, following complex extraction and offline derivatization of PDIMs biomarkers, prior to their analysis by gas chromatography/mass spectrometry (GC/MS). METHODS: We developed and optimized a GC/MS method based on selected ion monitoring (SIM) to detect the derivatives produced via the thermally assisted hydrolysis and methylation (THM) of the PDIMs from the cell membrane of M. tuberculosis. The extraction of PDIMs from culture is simple, and their thermochemolysis is carried out automatically online, thus avoiding the time-consuming derivatization steps of hydrolysis and esterification, usually performed offline. RESULTS: For standard PDIMs in petroleum ether, our optimized method gave an excellent linearity (R(2) = 0.99) at concentrations between 0.172 and 27.5 ng/mL, a good precision (RSD = 11.42%), and a limit of detection (LOD) of 100 pg/mL. For the PDIMs extracted from dilutions of M. tuberculosis culture, the method gave good linearity (R(2) = 0.9685) and an estimated LOD of 400 CFU/mL (CFU = colony forming units) in sterile distilled water. CONCLUSIONS: A GC/MS(SIM) method is presented for the rapid and quantitative detection of M. tuberculosis, based on the online thermochemolysis of lipidic biomarkers extracted from the bacterial culture. The method has the potential to be applied in human and veterinary clinical laboratories for the rapid diagnosis of tuberculosis in infected biological samples.


Assuntos
Antígenos de Bactérias/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Lipídeos/análise , Mycobacterium tuberculosis/isolamento & purificação , Cromatografia Gasosa-Espectrometria de Massas/economia , Humanos , Hidrólise , Limite de Detecção , Tuberculose/diagnóstico , Tuberculose/microbiologia
18.
Anal Sci ; 29(6): 649-53, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23749132

RESUMO

An analytical method was developed for the extraction and determination of pyrethroid pesticide residues in tobacco. The modified QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method was applied for preparing samples. In this study, methyl cyanide (MeCN)-saturated salt aqueous was used as the two-phase extraction solvent for the first time, and a vortex shaker was used for the simultaneous shaking and concentration of the analytes. The effects of experimental parameters on extraction and clean-up efficiency were investigated and optimized. The analytes were determined by gas chromatography-mass spectrometry-selected ion monitoring (GC-MS-SIM). The obtained recoveries of the analytes at three different fortification levels were 76.85-114.1% and relative standard deviations (RSDs) were lower than 15.7%. The limits of quantification (LOQs) were from 1.28 to 26.6 µg kg(-1). This method was also applied to the analysis of actual commercial tobacco products and the analytical results were satisfactory.


Assuntos
Técnicas de Química Analítica/métodos , Contaminação de Alimentos/análise , Cromatografia Gasosa-Espectrometria de Massas , Nicotiana/química , Resíduos de Praguicidas/química , Piretrinas/química , Acetonitrilas/química , Cromatografia Gasosa-Espectrometria de Massas/economia , Limite de Detecção , Fatores de Tempo
19.
Anal Bioanal Chem ; 405(22): 7107-16, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23715673

RESUMO

Comprehensive multi-dimensional hyphenation of a thermogravimetry device (i.e. a thermobalance) to gas chromatography and single photon ionization-time-of-flight mass spectrometry (TG-GC×SPI-MS) has been used to investigate two crude oil samples of different geographical origin. The source of the applied vacuum ultraviolet radiation is an electron beam pumped rare gas excimer lamp (EBEL). The soft photoionization favors the formation of molecular ions. Introduction of a fast, rapidly modulated gas chromatographic separation step in comparison with solely TG-SPI-MS enables strongly enhanced detection especially with such highly complex organic matrices as crude oil. In contrast with former TG-SPI-MS measurements, separation and identification of overlying substances is possible because of different GC retention times. The specific contribution of isobaric compounds to one mass signal is determined for alkanes, naphthalenes, alkylated benzenes, and other compounds.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Petróleo/análise , Termogravimetria/instrumentação , Desenho de Equipamento , Cromatografia Gasosa-Espectrometria de Massas/economia , Fatores de Tempo
20.
Artigo em Inglês | MEDLINE | ID: mdl-23603296

RESUMO

Rapid determination of nerve agent biomarkers at low-ppb levels in urine samples was achieved by direct derivatization and sample analysis using gas chromatography-tandem mass spectrometry. The studied biomarkers were alkylphosphonic acids (APAs), as they are specific hydrolysis products of organophosphorus nerve agents that can be used to verify nerve agent exposure. The sample preparation technique employed involves rapid direct derivatization (5min) of acidified urine samples (25µL) using a highly fluorinated phenyldiazomethane reagent [1-(diazomethyl)-3,5-bis(trifluoromethyl)benzene]. The derivatization conditions were optimized using statistical experimental design and multivariate data analysis. The APA derivatives were analyzed by GC-MS and MS/MS using negative ion chemical ionization. The selectivity and sensitivity of analyses performed by low and high resolution single ion monitoring MS-mode were compared with those performed by multiple reaction monitoring MS/MS-mode. The MS/MS technique offered the greatest sensitivity and selectivity of the tested mass spectrometric techniques, with limits of detection ranging from 0.5 to 1ng APAs/mL of urine. The method's robustness was evaluated using urine samples from the OPCW 2nd biomedical confidence building exercise and all APAs present in the samples were conclusively identified. The method thus offers excellent performance and is viable for the simultaneous trace determination of a wide range of nerve agent markers.


Assuntos
Substâncias para a Guerra Química/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Compostos Organofosforados/urina , Ácidos Fosforosos/urina , Espectrometria de Massas em Tandem/métodos , Biomarcadores/análise , Biomarcadores/urina , Cromatografia Gasosa-Espectrometria de Massas/economia , Humanos , Limite de Detecção , Compostos Organofosforados/análise , Ácidos Fosforosos/análise , Espectrometria de Massas em Tandem/economia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA