Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 276
Filtrar
1.
Molecules ; 27(1)2022 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-35011540

RESUMO

Pexidartinib is the first drug approved by the U.S. Food and Drug Administration specifically to treat the rare joint tumor tenosynovial giant cell tumor. In the current study, a validated, selective, and sensitive UPLC-MS/MS assay was developed for the quantitative determination of pexidartinib in plasma samples using gifitinib as an internal standard (IS). Pexidartinib and IS were extracted by liquid-liquid extraction using methyl tert-butyl ether and separated on an acquity BEH C18 column kept at 40 °C using a mobile phase of 0.1% formic acid in acetonitrile: 0.1% formic acid in de-ionized water (70:30). The flow rate was 0.25 mL/min. Multiple reaction monitoring (MRM) was operated in electrospray (ESI)-positive mode at the ion transition of 418.06 > 165.0 for the analyte and 447.09 > 128.0 for the IS. FDA guidance for bioanalytical method validation was followed in method validation. The linearity of the established UPLC-MS/MS assay ranged from 0.5 to 1000 ng/mL with r > 0.999 with a limit of quantitation of 0.5 ng/mL. Moreover, the metabolic stability of pexidartinib in liver microsomes was estimated.


Assuntos
Aminopiridinas/farmacocinética , Antineoplásicos Imunológicos/farmacocinética , Cromatografia Líquida de Alta Pressão , Inibidores de Proteínas Quinases/farmacocinética , Pirróis/farmacocinética , Espectrometria de Massas em Tandem , Aminopiridinas/química , Antineoplásicos Imunológicos/química , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Monitoramento de Medicamentos/métodos , Monitoramento de Medicamentos/normas , Estabilidade de Medicamentos , Estrutura Molecular , Inibidores de Proteínas Quinases/química , Pirróis/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas
2.
Assay Drug Dev Technol ; 19(8): 475-483, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34665025

RESUMO

Corona virus disease 2019 (COVID-19) has posed a mounting threat to public health with worldwide outbreak caused by a novel virus named severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Recently, remdesivir (RDV) has been approved by Food and Drug Administration (FDA) for treating COVID-19 patients ≥12 years old requiring hospitalization. To the best of our knowledge, a simple method to estimate RDV in the pharmaceutical formulations using high-performance liquid chromatography (HPLC) is still unexplored, highlighting the need for a precise analytical method for its quantification. The prime purpose of the current investigation was to develop and validate a well-grounded HPLC method for quantification of RDV in pharmaceutical formulations. The best chromatogram was obtained by means of an Inertsil ODS-3V column using a mobile phase of milli-Q water modified to pH 3.0 with o-phosphoric acid and acetonitrile (50:50, % v/v) at a flow rate of 1.2 mL/min and wavelength of detector set at 246 nm with retention time being achieved at 6.0 min. The method was validated following International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH) Q2 (R1) guidelines for various parameters such as specificity and selectivity, system suitability, linearity, precision, accuracy, limits of detection and quantification, and robustness. The method developed for the quantification of RDV was found to be linear in the concentration range of 25-2,500 ng/mL with limit of detection and limit of quantification of 1.95 and 6.49 ng/mL, respectively. Assay value of 102% ± 1% was achieved for marketed injectable dosage form when estimated by the validated method. Therefore, in this study a simple, rapid, sensitive, selective, accurate, precise, and robust analytical method was developed and validated for the quantification of RDV using HPLC. The established method was successfully employed for quantification of RDV in marketed pharmaceutical formulation.


Assuntos
Monofosfato de Adenosina/análogos & derivados , Administração Intravenosa/normas , Alanina/análogos & derivados , Antivirais/administração & dosagem , Antivirais/análise , Tratamento Farmacológico da COVID-19 , Monofosfato de Adenosina/administração & dosagem , Monofosfato de Adenosina/análise , Monofosfato de Adenosina/química , Administração Intravenosa/métodos , Alanina/administração & dosagem , Alanina/análise , Alanina/química , Antivirais/química , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Formas de Dosagem/normas , Humanos , Reprodutibilidade dos Testes
3.
Anal Bioanal Chem ; 413(21): 5483-5491, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34287657

RESUMO

Zearalenone (ZEN), an estrogenic mycotoxin produced by several species of Fusarium fungi, is a common contaminant of cereal-based food worldwide. Due to frequent occurrences associated with high levels of ZEN, maize oil is a particular source of exposure. Although a European maximum level for ZEN in maize oil exists according to Commission Regulation (EC) No. 1126/2007 along with a newly developed international standard method for analysis, certified reference materials (CRM) are still not available. To overcome this lack, the first CRM for the determination of ZEN in contaminated maize germ oil (ERM®-BC715) was developed in the frame of a European Reference Materials (ERM®) project according to the requirements of ISO Guide 35. The whole process of CRM development including preparation, homogeneity and stability studies, and value assignment is presented. The assignment of the certified mass fraction was based upon an in-house study using high-performance liquid chromatography isotope dilution tandem mass spectrometry. Simultaneously, to support the in-house certification study, an interlaboratory comparison study was conducted with 13 expert laboratories using different analytical methods. The certified mass fraction and expanded uncertainty (k = 2) of ERM®-BC715 (362 ± 22) µg kg-1 ZEN are traceable to the SI. This reference material is intended for analytical quality control and contributes to the improvement of consumer protection and food safety.


Assuntos
Óleo de Milho/química , Zearalenona/análise , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Contaminação de Alimentos/análise , Controle de Qualidade , Padrões de Referência , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Zea mays/química
4.
Sci Rep ; 11(1): 11936, 2021 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-34099770

RESUMO

The present study introduces a systematic approach using analytical quality by design (AQbD) methodology for the development of a qualified liquid chromatographic analytical method, which is a challenge in herbal medicinal products due to the intrinsic complex components of botanical sources. The ultra-high-performance liquid chromatography-photodiode array-mass spectrometry (UHPLC-PDA-MS) technique for 11 flavonoids in Genkwa Flos was utilized through the entire analytical processes, from the risk assessment study to the factor screening test, and finally in method optimization employing central composite design (CCD). In this approach, column temperature and mobile solvent slope were found to be critical method parameters (CMPs) and each of the eleven flavonoid peaks' resolution values were used as critical method attributes (CMAs) through data mining conversion formulas. An optimum chromatographic method in the design space was calculated by mathematical and response surface methodology (RSM). The established chromatographic condition is as follows: acetonitrile and 0.1% formic acid gradient elution (0-13 min, 10-45%; 13-13.5 min, 45-100%; 13.5-14 min, 100-10%; 14-15 min, 10% acetonitrile), column temperature 28℃, detection wavelength 335 nm, and flow rate 0.35 mL/min using C18 (50 × 2.1 mm, 1.7 µm) column. A validation study was also performed successfully for apigenin 7-O-glucuronide, apigenin, and genkwanin. A few important validation results were as follows: linearity over 0.999 coefficient of correlation, detection limit of 2.87-22.41, quantitation limit of 8.70-67.92, relative standard deviation of precision less than 0.22%, and accuracy between 100.13 and 102.49% for apigenin, genkwanin, and apigenin 7-O-glucuronide. In conclusion, the present design-based approach provide a systematic platform that can be effectively applied to ensure pharmaceutically qualified analytical data from complex natural products based botanical drug.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Flavonoides/análise , Flores/química , Espectrometria de Massas/métodos , Plantas Medicinais/química , Cromatografia Líquida de Alta Pressão/normas , Flavonoides/química , Espectrometria de Massas/normas , Estrutura Molecular , Controle de Qualidade , Reprodutibilidade dos Testes
5.
J Chromatogr A ; 1643: 462060, 2021 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-33770631

RESUMO

Numerous epidemiological studies have indicated the potential effects of glucosinolates and their metabolites against cancer as well as other non-communicable diseases, such as cardiovascular disease and neurodegenerative disorders. However, information on the presence and quantity of glucosinolates in commonly consumed vegetables and in human fluids is sparse, largely because well-standardised methods for glucosinolate determination are not available, resulting in published data being inconsistent and conflicting. Thus, studies published since 2002 on the most recent developments of glucosinolate extraction and identification have been collected and reviewed with emphasis on determination of the intact glucosinolates by LC-MS and LC-MS/MS. This overview highlights the glucosinolate extraction methods used, the stability of glucosinolates during extraction, the availability of stable isotope labelled internal standards and the use of NMR for purity analysis, as well as the current analytical techniques that have been applied for glucosinolate analysis, e.g. liquid chromatography with mass spectrometric detection (LC-MS). It aims to interpret the findings with a focus on the development of a validated method, which will help to determine the glucosinolate content of vegetative plants and human tissues, and the identification and determination of selected glucosinolate metabolites.


Assuntos
Glucosinolatos/análise , Verduras/química , Cromatografia Gasosa/normas , Cromatografia Líquida de Alta Pressão/normas , Ensaio de Imunoadsorção Enzimática , Glucosinolatos/sangue , Glucosinolatos/normas , Glucosinolatos/urina , Humanos , Extração Líquido-Líquido , Folhas de Planta/química , Folhas de Planta/metabolismo , Raízes de Plantas/química , Raízes de Plantas/metabolismo , Plantas/química , Plantas/metabolismo , Padrões de Referência , Espectrometria de Massas em Tandem/normas , Verduras/metabolismo
6.
Sci Rep ; 11(1): 3132, 2021 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-33542452

RESUMO

Combination therapy of tegafur/uracil (UFT) and leucovorin (LV) is widely used to treat colorectal cancers. Although this therapy has a significant therapeutic effect, severe adverse effects occur frequently. Therapeutic drug monitoring (TDM) may help to prevent adverse effects. A useful assay that can quantitate plasma levels of 5-FU, uracil, and tegafur simultaneously for TDM has been desired, but such a method is not currently available. In this study, we aimed to develop a sensitive method for simultaneous quantification of 5-FU, uracil, and tegafur in human plasma using ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS). After preparing plasma samples by protein precipitation and liquid extraction, 5-FU, uracil, and tegafur were analyzed by UPLC-MS/MS in negative electrospray ionization mode. Validation was performed according to US Food and Drugs Administration guidance. The calibration curves were linear over concentration ranges of 2-500 ng/mL for 5-FU, 20-5000 ng/mL for uracil, and 200-50,000 ng/mL for tegafur. The corresponding average recovery rates were 79.9, 80.9, and 87.8%. The method provides accuracy within 11.6% and precision below 13.3% for all three analytes. Matrix effects of 5-FU, uracil, and tegafur were higher than 43.5, 84.9, and 100.2%, respectively. This assay was successfully applied to assess the time courses of plasma 5-FU, uracil, and tegafur concentrations in two patients with colorectal liver metastasis who received UFT/LV therapy after hepatectomy. In conclusion, we succeeded to develop a sensitive and robust UPLC-MS/MS method for simultaneous quantification of 5-FU, uracil, and tegafur in human plasma. This method is potentially useful for TDM in patients receiving UFT/LV combination therapy.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Cromatografia Líquida de Alta Pressão/normas , Monitoramento de Medicamentos/métodos , Fluoruracila/sangue , Espectrometria de Massas em Tandem/normas , Tegafur/sangue , Uracila/sangue , Antimetabólitos Antineoplásicos/sangue , Calibragem , Cromatografia Líquida de Alta Pressão/métodos , Neoplasias Colorretais/sangue , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/patologia , Hepatectomia/métodos , Humanos , Leucovorina/uso terapêutico , Fígado/patologia , Fígado/cirurgia , Neoplasias Hepáticas/sangue , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/métodos
7.
Toxicol Lett ; 338: 67-77, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33290830

RESUMO

Chemical-peptide conjugation is the molecular initiating event in skin sensitization. The OECD test guideline uses a high-performance liquid chromatography/ultraviolet (HPLC/UV) detection method to quantify chemical-peptide conjugation in a direct peptide reactivity assay (DPRA), which measures the depletion of two synthetic peptides containing lysine or cysteine residues. To improve assay throughput, sensitivity and accuracy, an automated 384-well plate-based RapidFire solid-phase extraction (SPE) system coupled with tandem mass spectrometry (MS/MS) DPRA was developed and validated in the presence of a newly designed internal standard. Compared to the HPLC/UV-based DPRA, the automated SPE-MS/MS-based DPRA improved throughput from 16 min to 10 s per sample, and substrate peptides usage was reduced from 100 mM to 5 µM. When implementing the SPE-MS/MS-based DPRA into a high-throughput platform, we found 10 compounds that depleted lysine peptide and 24 compounds that depleted cysteine peptide (including 7 unreported chemicals from 55 compounds we tested) in a concentration-response manner. The adduct formation between cysteine and cinnamic aldehyde and ethylene glycol dimethacrylate were further analyzed using high-performance liquid chromatography time-of-flight mass spectrometry (HPLC-TOF-MS) to confirm the conjugation. Overall, the automated SPE-MS/MS-based platform is an efficient, economic, and accurate way to detect skin sensitizers.


Assuntos
Alérgenos/toxicidade , Cromatografia Líquida de Alta Pressão , Dermatite Alérgica de Contato/etiologia , Ensaios de Triagem em Larga Escala , Peptídeos/química , Pele/efeitos dos fármacos , Espectrometria de Massas em Tandem , Testes de Toxicidade , Alérgenos/química , Alternativas aos Testes com Animais , Cromatografia Líquida de Alta Pressão/normas , Cisteína , Ensaios de Triagem em Larga Escala/normas , Humanos , Lisina , Padrões de Referência , Reprodutibilidade dos Testes , Medição de Risco , Espectrometria de Massas em Tandem/normas
8.
Eur J Drug Metab Pharmacokinet ; 46(1): 155-159, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33231835

RESUMO

BACKGROUND AND OBJECTIVES: Busulfan (Bu) is an old drug, but is still well recommended as an alkylating agent during conditioning therapy, before hematopoietic stem cell transplantation. Although its dose administration is standardized and based on patient weight, therapeutic drug monitoring is required in order to maintain its exposure [as area under the concentration-time curve (AUC) from 0 to infinity AUC0-∞] within a narrow therapeutic range and, if necessary, to adjust the dose with as short a lead time as possible. The aim of the study is to evaluate the agreement (as calculated AUC) between a gold standard analytical method and a new one that is faster and easier. METHODS: We analyzed 221 plasma samples from 37 children (0.25-16 years; 4-62.5 kg) and 11 adults (21-59 years; 45-80 kg), corresponding to 52 AUC values (ng h/mL). The drug exposure was calculated, simultaneously, by two validated analytical methods. The reference method was a high-performance liquid chromatography (HPLC) assay combined with an ultraviolet detector (UV). The test method had a triple quadrupole mass spectrometer (MS) as detector; the clean-up procedures of the samples were different and faster. RESULTS: The agreement between the two methods (reference and test) was evaluated in terms of Bu exposure differences based on Lin's concordance correlation coefficient (CCC) and represented by the Bland-Altman plot. The CCC between the AUC of the two methods was excellent (0.868; 95% CI: 0.802-0.935). The precision of the measures (expressed by Pearson's italic "r") was 0.872, and the accuracy (accounted by the bias correction factor) was 0.996. CONCLUSIONS: We can conclude that the HPLC-MS/MS assay represents a very good alternative to the reference.


Assuntos
Alquilantes/administração & dosagem , Alquilantes/sangue , Bussulfano/administração & dosagem , Bussulfano/sangue , Monitoramento de Medicamentos/normas , Adolescente , Adulto , Criança , Pré-Escolar , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Estudos de Coortes , Monitoramento de Medicamentos/métodos , Feminino , Humanos , Lactente , Infusões Intravenosas , Masculino , Espectrometria de Massas/métodos , Espectrometria de Massas/normas , Pessoa de Meia-Idade , Adulto Jovem
9.
J Chromatogr A ; 1626: 461333, 2020 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-32797819

RESUMO

The ultra-trace determination of nicotine and its 4 major metabolites (cotinine, nornicotine, norcotinine and anabasine) from rabbit plasma was achieved by a newly developed solid phase microextraction-liquid chromatography-tandem mass spectrometry method. Extraction of the target analytes was performed with hydrophilic/lipophilic balance-polyacrylonitrile SPME fibers. Dual fiber extraction was necessary to guarantee improved recovery at parts-per-trillion levels. Liquid chromatographic analysis was achieved in a 6-min run using a C18 (1.9 µm C18, 50 mm x 2.1 mm) column with a mobile phase flow rate of 0.4 mL/min. Tandem mass spectrometry was used for detection and quantification in positive electrospray ionization (ESI+) mode for all the targeted analytes. Two stable isotope-labeled internal standards were used for signal correction and accurate quantification. The mass spectrometer with laminar flow ion flux transport, guaranteed improved signal stability, minimal contamination of the ion guide and reproducibility into the first quadrupole analyzer. The method was validated in line with the Food and Drug Administration (FDA) guidelines for bioanalytical method validation. The results met the acceptance criteria as proposed by the FDA: accuracy was tested at 0.35, 10 and 75 µg L - 1 and ranged between 98.3-112.2% for nicotine, 94.1-101.9% for cotinine, 94.7-107.0% for nornicotine, 81.1-107.2% for norcotinine and 94.3-115.2% for anabasine, with precision up to 14.2%. Stability tests indicated that all the targeted analytes were stable in the desorption solution for at least 1 week. LOQs ranged from 0.05 to 1 µg L-1. The method was successfully applied to analyze plasma samples obtained from rabbits following transdermal application of a smoking cessation formulation loaded with solid lipid nanoparticles containing a nicotine-stearic acid conjugate.


Assuntos
Nicotina/sangue , Anabasina/sangue , Anabasina/isolamento & purificação , Anabasina/normas , Animais , Cromatografia Líquida de Alta Pressão/normas , Cotinina/análogos & derivados , Cotinina/sangue , Cotinina/isolamento & purificação , Cotinina/normas , Marcação por Isótopo , Limite de Detecção , Nicotina/análogos & derivados , Nicotina/isolamento & purificação , Nicotina/metabolismo , Nicotina/normas , Coelhos , Padrões de Referência , Reprodutibilidade dos Testes , Abandono do Hábito de Fumar , Microextração em Fase Sólida , Espectrometria de Massas em Tandem/normas , Fatores de Tempo
10.
J Chromatogr A ; 1626: 461377, 2020 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-32797853

RESUMO

This study reports the use ofa natural deep eutectic solvent (NADES) with hollow fiber-microporous membrane liquid-liquid microextraction (HF-MMLLE) for the multiclass determination of 11 compounds classified as emerging contaminantsin water. Different deep eutectic solvents were synthetized and Thymol: Camphor (1:1 molar fraction) wasused as extraction solvent. The Thymol:Camphor was impregnated into the polypropylene membrane porous for 10 min, replacing commonly used solvents (ex. hexane and octanol). The optimized parameters were obtained by multi and univariate models. Extractions were carried out for 50 min using 1.5 mL of water sample at pH 6 and without addition of salt while desorption was made in a mixture of acetone: methanol (3:1, v/v) for 15 min. Separation/quantification was conducted by HPLC with a diode array detection (DAD)and calibration curves were obtained for each analyte. Determination coefficients higher than 0.9906 and limits of detection ranged from 0.3 to 6.1 µg L-1. Intraday precision (n = 3) ranged from 1.6 to 18.4% and inter day from 5.0 to 21.3%. Relative recoveries were performed in tap and stream water and ranged from 64 to 123%.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Microextração em Fase Líquida/métodos , Solventes/química , Poluentes Químicos da Água/análise , Calibragem , Cromatografia Líquida de Alta Pressão/normas , Interações Hidrofóbicas e Hidrofílicas , Membranas Artificiais , Polipropilenos/química , Porosidade , Espectrofotometria , Poluentes Químicos da Água/isolamento & purificação , Poluentes Químicos da Água/normas
11.
Anal Chem ; 92(13): 9072-9078, 2020 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-32484659

RESUMO

Plasma-free metanephrines and catecholamines are essential markers in the biochemical diagnosis and follow-up of neuroendocrine tumors and inborn errors of metabolism. However, their low circulating concentrations (in the nanomolar range) and poor fragmentation characteristics hinder facile simultaneous quantification by liquid chromatography and tandem mass spectrometry (LC-MS/MS). Here, we present a sensitive and simple matrix derivatization procedure using propionic anhydride that enables simultaneous quantification of unconjugated l-DOPA, catecholamines, and metanephrines in plasma by LC-MS/MS. Dilution of propionic anhydride 1:4 (v/v) in acetonitrile in combination with 50 µL of plasma resulted in the highest mass spectrometric response. In plasma, derivatization resulted in stable derivatives and increased sensitivity by a factor of 4-30 compared with a previous LC-MS/MS method for measuring plasma metanephrines in our laboratory. Furthermore, propionylation increased specificity, especially for 3-methoxytyramine, by preventing interference from antihypertensive medication (ß-blockers). The method was validated according to international guidelines and correlated with a hydrophilic interaction LC-MS/MS method for measuring plasma metanephrines (R2 > 0.99) and high-performance liquid chromatography with an electrochemical detection method for measuring plasma catecholamines (R2 > 0.85). Reference intervals for l-DOPA, catecholamines, and metanephrines in n = 115 healthy individuals were established. Our work shows that analytes in the subnanomolar range in plasma can be derivatized in situ without any preceding sample extraction. The developed method shows improved sensitivity and selectivity over existing methods and enables simultaneous quantification of several classes of amines.


Assuntos
Catecolaminas/sangue , Metanefrina/sangue , Espectrometria de Massas em Tandem/métodos , Catecolaminas/isolamento & purificação , Catecolaminas/normas , Cromatografia Líquida de Alta Pressão/normas , Dopamina/análogos & derivados , Dopamina/sangue , Dopamina/isolamento & purificação , Dopamina/normas , Humanos , Levodopa/sangue , Levodopa/isolamento & purificação , Levodopa/normas , Limite de Detecção , Metanefrina/isolamento & purificação , Metanefrina/normas , Valores de Referência , Extração em Fase Sólida , Espectrometria de Massas em Tandem/normas
12.
Eur J Hosp Pharm ; 27(e1): e69-e73, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32296509

RESUMO

Introduction: Nefopam has been reported to be effective in postoperative pain control with an opioid-sparing effect, but the use of nefopam can lead to nausea and vomiting. To prevent these side effects, droperidol can be mixed with nefopam. In intensive care units, high concentrations of nefopam and droperidol in syringes can be used with a continuous flow. Objectives: The first objective of this work was to study the physicochemical stability of a nefopam solution 2.5 mg/mL diluted in NaCl 0.9% in polypropylene syringes immediately after preparation and after 6, 24 and 48 hours at room temperature. The second objective was to study the physicochemical stability of mixtures of nefopam 2.5 mg/mL and droperidol 52 µg/mL diluted in NaCl 0.9% in polypropylene syringes at room temperature over 48 hours. Materials and methods: Three syringes for each condition were prepared. For each time of analysis, three samples for each syringe were prepared and analysed by high performance liquid chromatography coupled to photodiode array detection. The method was validated according to the International Conference on Harmonisation Q2(R1). Physical stability was evaluated by visual and subvisual inspection (turbidimetry by UV spectrophotometry). pH values were measured at each time of analysis. Results: Solutions of nefopam at 2.5 mg/mL and the mixture of nefopam 2.5 mg/mL with droperidol 52 µg/mL, diluted in NaCl 0.9%, without protection from light, retained more than 90% of the initial concentration after 48 hours storage at 20-25°C. No modification in visual or subvisual evaluation and pH values were observed. Conclusion: Nefopam solutions at 2.5 mg/mL and the mixture of nefopam 2.5 mg/mL with droperidol 52 µg/mL diluted in NaCl 0.9% were stable over a period of 48 hours at room temperature. These stability data provide additional knowledge to assist intensive care services in daily practice.


Assuntos
Droperidol/química , Unidades de Terapia Intensiva/normas , Nefopam/química , Polipropilenos/química , Seringas/normas , Fenômenos Químicos , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Droperidol/análise , Humanos , Nefopam/análise , Soluções Farmacêuticas/análise , Soluções Farmacêuticas/química , Polipropilenos/análise
13.
Molecules ; 25(7)2020 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-32283791

RESUMO

Homocysteine and related thiols (cysteine, cysteinylglycine, and glutathione) in the urine of a cystathionine ß-synthase (CBS)-deficient mouse model were quantified using hydrophilic interaction chromatography with fluorescence detection. Urine samples were incubated with tris(2-carboxyethyl) phosphine to reduce disulfide bonds into thiols. After deproteinization, thiols were fluorescently derivatized with ammonium 7-fluoro-2,1,3-benzoxadiazole-4-sulfonate (SBD-F). Homocysteine, cysteine, cysteinylglycine, and glutathione in mouse urine were analyzed using an amide-type column with a mobile phase of acetonitrile/120 mM ammonium formate buffer (pH 3.0) (81:19). The developed method was well-validated. Thiol concentrations in the urine of CBS-wild type (-WT), -heterozygous (-Hetero), and -knockout (-KO) mice were quantified using the developed method. As expected, total homocysteine concentration in CBS-KO mice was significantly higher than that in CBS-WT and CBS-Hetero mice. The developed method shows promise for diagnoses in preclinical and clinical studies.


Assuntos
Cromatografia , Cistationina beta-Sintase/deficiência , Homocistinúria/etiologia , Homocistinúria/urina , Compostos de Sulfidrila/urina , Animais , Biomarcadores , Cromatografia/métodos , Cromatografia/normas , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Modelos Animais de Doenças , Camundongos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Compostos de Sulfidrila/isolamento & purificação
14.
Pak J Pharm Sci ; 33(2): 685-694, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32276915

RESUMO

Curcumin (Diferuloylmethane) is a natural product extracted from the root of Curcuma longa. 5-Bis (4-hydroxy-3-methoxybenzylidene)-N-methyl-4-piperidone, the piperidone analogue of curcumin (PAC), was one of the analogues that, demonstrated potential anticancer effects against breast and colon cancers compared with native curcumin. A simple, accurate, and rapid isocratic reverse phase high performance liquid chromatography (HPLC) analytical method utilizing UV detection was developed and validated for the determination of PAC utilizing C18 column with run time was 7 min. Chromatogram showed a peak of PAC at retention time of 5.8±0.92 min. The method was validated for linearity, accuracy, precision, limit of detection, limit of quantitation and robustness. Linear relationship (r > 0.99) was observed between AUP of PAC and the corresponding concentrations over 100-10000µg/mL. The LOQ of this assay was 3.9ng/mL with a corresponding relative standard deviation of 4.8 and 4.0%. The LOD was 13.1ng/mL at a signal-to-noise ratio of >3.


Assuntos
Cromatografia de Fase Reversa/métodos , Cromatografia de Fase Reversa/normas , Curcumina/análise , Curcumina/química , Piperidonas/análise , Piperidonas/química , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Reprodutibilidade dos Testes
15.
J Pharm Biomed Anal ; 185: 113245, 2020 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-32199328

RESUMO

A highly sensitive method was developed to quantitate the antileishmanial agent paromomycin in human plasma, with a lower limit of quantification of 5 ng/mL. Separation was achieved using an isocratic ion-pair ultra-high performance liquid chromatographic (UPLC) method with a minimal concentration of heptafluorobutyric acid, which was coupled through an electrospray ionization interface to a triple quadrupole - linear ion trap mass spectrometer for detection. The method was validated over a linear calibration range of 5 to 1000 ng/mL (r2≥0.997) with inter-assay accuracies and precisions within the internationally accepted criteria. Volumes of 50 µL of human K2EDTA plasma were processed by using a simple protein precipitation method with 40 µL 20 % trichloroacetic acid. A good performance was shown in terms of recovery (100 %), matrix effect (C.V. ≤ 12.0 %) and carry-over (≤17.5 % of the lower limit of quantitation). Paromomycin spiked to human plasma samples was stable for at least 24 h at room temperature, 6 h at 35 °C, and 104 days at -20 °C. Paromomycin adsorbs to glass containers at low concentrations, and therefore acidic conditions were used throughout the assay, in combination with polypropylene tubes and autosampler vials. The assay was successfully applied in a pharmacokinetic study in visceral leishmaniasis patients from Eastern Africa.


Assuntos
Antiprotozoários/sangue , Monitoramento de Medicamentos/métodos , Leishmaniose Visceral/tratamento farmacológico , Paromomicina/sangue , Adsorção , África Oriental , Antiprotozoários/administração & dosagem , Antiprotozoários/química , Antiprotozoários/farmacocinética , Calibragem , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Estabilidade de Medicamentos , Humanos , Injeções Intramusculares , Leishmaniose Visceral/sangue , Limite de Detecção , Paromomicina/administração & dosagem , Paromomicina/química , Paromomicina/farmacocinética , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Ácido Tricloroacético/química
16.
AAPS J ; 22(2): 43, 2020 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-32030538

RESUMO

The addition of rabbit anti-human thymocyte globulin (ATG) to the conditioning regimen prior to allogeneic hematopoietic cell transplantation has significantly reduced the risk of graft-versus-host disease (GvHD) and graft failure. However, ATG has a small therapeutic window. Overexposure of ATG post-HCT hampers T cell immune reconstitution and has been associated with increased relapse rates and viral reactivations, whereas underexposure has been associated with an increased incidence of GvHD, both of which lead to increased mortality. Therapeutic drug monitoring of T cell binding ATG plasma levels provides a means to optimize dosing for patients at high risk for graft failure to ensure timely T cell immune reconstitution and subsequently increase survival chances. This manuscript describes the first liquid chromatography tandem-mass spectrometry (LC-MS/MS) method to quantify the pharmacologically active fraction of polyclonal ATG in plasma. This was achieved through immunoaffinity purification of active ATG from plasma with Jurkat T cells. After the binding and washing, samples were eluted, denatured, and trypsin-digested. Signature peptides originating from the IgG constant chain were measured with LC-MS/MS. Critical method parameters were optimized, and the method was successfully validated following European Medicines Agency (EMA) guidelines. The method covered the therapeutic range of ATG and was validated at a lower limit of quantification (LLOQ) of 1 AU/mL with an overall CV and bias of 11.8% and - 2.5%, respectively. In conclusion, we developed a LC-MS/MS-based method to quantify active polyclonal rabbit ATG in human plasma. We suggest that this novel assay can be used to monitor and optimize dosing of ATG in clinical practice.


Assuntos
Soro Antilinfocitário/sangue , Cromatografia Líquida de Alta Pressão , Monitoramento de Medicamentos , Imunossupressores/sangue , Espectrometria de Massas em Tandem , Soro Antilinfocitário/administração & dosagem , Cromatografia Líquida de Alta Pressão/normas , Monitoramento de Medicamentos/normas , Humanos , Imunossupressores/administração & dosagem , Células Jurkat , Limite de Detecção , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/normas
17.
J Chromatogr A ; 1618: 460905, 2020 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-32008825

RESUMO

Retention time shifts in second-order calibration-assisted chromatographic analysis seriously impact the modeling and quantitative accuracies in complex systems. In this work, three second-order methods, i.e. alternating trilinear decomposition (ATLD) algorithm, multivariate curve resolution-alternating least squares (MCR-ALS), alternating trilinear decomposition-assisted multivariate curve resolution (ATLD-MCR), were compared their performance to process liquid chromatographic data in the presence of retention time shifts and overlapped peaks. Firstly, the validation samples contain five tea polyphenols at three concentrate levels within the calibration ranges, helped to understand, visualize and interpret these features of three second-order multivariate methods. Secondly, experimental data were studied concerning the determination of polyphenols in Chinese tea samples by HPLC-DAD. The results showed that all three second-order multivariate methods realized satisfactory quantification for five targeted analytes in Pu-Er ripe tea samples and Green tea samples even with the interference of slight retention time shifts, average recoveries were 91.23% -113.16% for ATLD, 89.96%-115.96% for ATLD-MCR, 90.64%-117.60% for MCR-ALS, respectively. However, ATLD was disappointing in the case of larger time shifts (approx. 4.00 s and 6.40 s) occurring for the quantitative analysis of Black tea and Clinacanthus nutans tea, the average recoveries were just 67.33-84.05%. Relatively, MCR-ALS and ATLD-MCR were more significantly excellent, satisfactory results still can be obtained, the average recoveries for MCR-ALS and ATLD-MCR were in the range of 86.04-117.60% and 89.96-115.96%, respectively.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Polifenóis/análise , Chá/química , Algoritmos , Calibragem , Camellia sinensis/química , Cromatografia Líquida de Alta Pressão/normas , Análise dos Mínimos Quadrados , Análise Multivariada
18.
AAPS PharmSciTech ; 21(2): 70, 2020 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-31953771

RESUMO

Synthetic peptides used as therapeutic medicines is continuing to grow as an area of focus within the pharmaceutical industry due to specificity and potency. As such, quality control areas need to continue to advance their capabilities to ensure that appropriate analyses are being performed, and that the data generated are both accurate and precise. One area which poses a significant challenge compared with traditional small molecule drug products is having a highly robust, low variability method of quantifying the assay of the active substance. As many peptide therapeutics are formulated as liquid drug products for injection and preparation procedures to make these samples amenable to traditional chromatographic analysis are inherently low variability (i.e., a simple dilution), potential sources of variance derived from the preparation of the analytical standards used to quantify the assay of the product must be investigated. Here, a fully nested ANOVA experimental design was utilized to examine this process. Such a design allowed for multiple variables to be interrogated as well as the potential interplay of such differences. It was determined that sonication of the standards contributed the most variance, while the balance used and scale on which the standard preparation procedure was performed also contributed significantly. Finally, different procedures for introducing the material into a coulometric Karl Fischer (KF) titration device to quantify the water content of the drug substance were compared and showed that indirect quantification by anhydrous methanol extraction is a significantly more variable method than using an Oven KF autosampler.


Assuntos
Cromatografia Líquida de Alta Pressão/normas , Liofilização , Peptídeos/análise , Preparações Farmacêuticas/análise , Padrões de Referência , Análise de Variância , Cromatografia Líquida de Alta Pressão/métodos , Composição de Medicamentos/normas , Controle de Qualidade , Reprodutibilidade dos Testes , Sonicação , Água/análise
19.
Clin Chem Lab Med ; 58(5): 673-681, 2020 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-31527291

RESUMO

Background The widespread availability of cannabis raises concerns regarding its effect on driving performance and operation of complex equipment. Currently, there are no established safe driving limits regarding ∆9-tetrahydrocannabinol (THC) concentrations in blood or breath. Daily cannabis users build up a large body burden of THC with residual excretion for days or weeks after the start of abstinence. Therefore, it is critical to have a sensitive and specific analytical assay that quantifies THC, the main psychoactive component of cannabis, and multiple metabolites to improve interpretation of cannabinoids in blood; some analytes may indicate recent use. Methods A liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed to quantify THC, cannabinol (CBN), cannabidiol (CBD), 11-hydroxy-THC (11-OH-THC), (±)-11-nor-9-carboxy-Δ9-THC (THCCOOH), (+)-11-nor-Δ9-THC-9-carboxylic acid glucuronide (THCCOOH-gluc), cannabigerol (CBG), and tetrahydrocannabivarin (THCV) in whole blood (WB). WB samples were prepared by solid-phase extraction (SPE) and quantified by LC-MS/MS. A rapid and simple method involving methanol elution of THC in breath collected in SensAbues® devices was optimized. Results Lower limits of quantification ranged from 0.5 to 2 µg/L in WB. An LLOQ of 80 pg/pad was achieved for THC concentrations in breath. Calibration curves were linear (R2>0.995) with calibrator concentrations within ±15% of their target and quality control (QC) bias and imprecision ≤15%. No major matrix effects or drug interferences were observed. Conclusions The methods were robust and adequately quantified cannabinoids in biological blood and breath samples. These methods will be used to identify cannabinoid concentrations in an upcoming study of the effects of cannabis on driving.


Assuntos
Canabinoides/análise , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Testes Respiratórios , Canabidiol/análise , Canabidiol/sangue , Canabidiol/isolamento & purificação , Canabidiol/normas , Canabinoides/sangue , Canabinoides/isolamento & purificação , Canabinoides/normas , Cromatografia Líquida de Alta Pressão/normas , Ácido Cítrico/química , Dronabinol/análise , Dronabinol/sangue , Dronabinol/isolamento & purificação , Dronabinol/normas , Glucose/análogos & derivados , Glucose/química , Humanos , Limite de Detecção , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Fumar , Extração em Fase Sólida , Espectrometria de Massas em Tandem/normas , Estudos de Validação como Assunto
20.
PDA J Pharm Sci Technol ; 74(1): 2-14, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31209168

RESUMO

Urea is used in biopharmaceutical manufacturing processes for the purification of therapeutic proteins, for cleaning columns, and for refolding proteins after purification. The urea used for such purposes is typically USP grade material obtained from commercial sources and further characterization is required prior to use, such as determination of purity and identity. For this purpose, a robust analytical method is needed that can characterize the known organic impurities of urea. However, the existing methods show high assay variability and are not able to resolve all known organic impurities as desired for accurate quantification. In the present manuscript we developed a new high-performance liquid chromatography method with UV detection for the separation of urea and its impurities (biuret, cyanuric acid, and triuret). The method performance characteristics evaluated for urea and biuret were specificity, linearity, accuracy, identity, precision, and robustness and the newly developed method met all predefined performance acceptance criteria.


Assuntos
Contaminação de Medicamentos/prevenção & controle , Raios Ultravioleta , Ureia/análise , Ureia/normas , Cromatografia Líquida de Alta Pressão/normas , Cromatografia Líquida de Alta Pressão/tendências , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA