Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-32515314

RESUMO

BACKGROUND: Despite significant progress in the diagnosis of contact dermatitis, the identification by specific tests or biomarkers remains an unsolved issue, particularly when needed for the confirmation of the occupational origin of the disease. OBJECTIVE: To characterize the plasma proteome profile in occupational dermatitis in workers of paint industry. METHODS: The study has a case-control design, comparing exposed workers with and without occupational contact dermatitis, matched for age, gender, occupational history, and comorbidities. An immunological assay (Human XL Cytokine Array Kit - ARY022B, R&D Systems) was used to measure the plasma levels of 105 cytokines and chemokines in a pooled sample of the cases and a pooled sample of the controls. RESULTS: A 1.5-fold increase was noticed for interleukin 3, interleukin 10, and leptin in cases, as compared to controls. Fibroblast growth factor-7 and growth/differentiation factor-15 showed a 1.4-fold increase, while interleukin 19, interleukin 31, and macrophage inflammatory protein 3a.had only a 1.3- fold increase. The leukemia inhibitory factor was the only plasma cytokine that showed a 1.3-fold decrease. All other cytokines had a variation of less than 1.2-fold between cases and controls. CONCLUSION: The recognition of the molecular signatures is very important for an accurate and indisputable diagnosis of occupational contact dermatitis. In workers from the paint industry, plasma levels of interleukins 3, 10, 13 and 19, fibroblast growth factor-7, and growth/differentiation factor-15, together with leukemia inducible factor, may differentiate subjects with contact dermatitis from those without skin lesions.


Assuntos
Citocinas/sangue , Dermatite Ocupacional/sangue , Dermatite Ocupacional/diagnóstico , Pintura/efeitos adversos , Adulto , Biomarcadores/sangue , Estudos de Casos e Controles , Dermatite Ocupacional/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
2.
J Immunotoxicol ; 17(1): 122-134, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32449871

RESUMO

Occupational immune diseases are a serious public health burden and are often a result of exposure to low molecular weight (LMW) chemicals. The complete immunological mechanisms driving these responses are not fully understood which has made the classification of chemical allergens difficult. Antimicrobials are a large group of immunologically-diverse LMW agents. In these studies, mice were dermally exposed to representative antimicrobial chemicals (sensitizers: didecyldimethylammonium chloride (DDAC), ortho-phthalaldehyde (OPA), irritants: benzal-konium chloride (BAC), and adjuvant: triclosan (TCS)) and the mRNA expression of cytokines and cellular mediators was evaluated using real-time qPCR in various tissues over a 7-days period. All antimicrobials caused increases in the mRNA expression of the danger signals Tslp (skin), and S100a8 (skin, blood, lung). Expression of the TH2 cytokine Il4 peaked at different timepoints for the chemicals based on exposure duration. Unique expression profiles were identified for OPA (Il10 in lymph node, Il4 and Il13 in lung) and TCS (Tlr4 in skin). Additionally, all chemicals except OPA induced decreased expression of the cellular adhesion molecule Ecad. Overall, the results from these studies suggest that unique gene expression profiles are implicated following dermal exposure to various antimicrobial agents, warranting the need for additional studies. In order to advance the development of preventative and therapeutic strategies to combat immunological disease, underlying mechanisms of antimicrobial-induced immunomodulation must be fully understood. This understanding will aid in the development of more effective methods to screen for chemical toxicity, and may potentially lead to more effective treatment strategies for those suffering from immune diseases.


Assuntos
Anti-Infecciosos/efeitos adversos , Asma Ocupacional/imunologia , Dermatite Alérgica de Contato/imunologia , Dermatite Ocupacional/imunologia , Administração Cutânea , Alérgenos/administração & dosagem , Alérgenos/efeitos adversos , Animais , Anti-Infecciosos/administração & dosagem , Asma Ocupacional/sangue , Asma Ocupacional/induzido quimicamente , Asma Ocupacional/patologia , Calgranulina A/genética , Citocinas/genética , Dermatite Alérgica de Contato/sangue , Dermatite Alérgica de Contato/patologia , Dermatite Ocupacional/sangue , Dermatite Ocupacional/patologia , Modelos Animais de Doenças , Feminino , Perfilação da Expressão Gênica , Regulação da Expressão Gênica/efeitos dos fármacos , Regulação da Expressão Gênica/imunologia , Humanos , Irritantes/efeitos adversos , Pulmão/efeitos dos fármacos , Pulmão/imunologia , Pulmão/patologia , Camundongos , Exposição Ocupacional/efeitos adversos , Pele/efeitos dos fármacos , Pele/imunologia , Pele/patologia , Células Th2/efeitos dos fármacos , Células Th2/imunologia , Células Th2/metabolismo , Linfopoietina do Estroma do Timo
3.
Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi ; 35(10): 727-731, 2017 Oct 20.
Artigo em Chinês | MEDLINE | ID: mdl-29294541

RESUMO

Objective: To investigate the possible role of IL17-and IL22-secreting cells combined with patch test for the prediction of formaldehyde-induced occupational allergic contact dermatitis(OACD). Methods: From October 2014 to October 2016, totally 131 formaldehyde-exposed workers(49 cases with inflammatory skin lesions,82 ones without inflammatory skin lesions)and 63 non-exposed health controls were recruited. Patch-test was performed in 49 cases of formaldehyde-exposed workers with inflammatory skin lesions. Circulating IL17+and IL22+Tcell subsets were assessed by flow cytometry(FCM). Results: Among 49 cases of formaldehyde-exposed workers with inflammatory skin lesions,32 cases were with positive patch-test while 17 cases with negative patch-test. The proportions of circulating CD3+CD8-IL17+ and CD3+CD8-IL22+ cells from patch-test(+) formaldehyde-exposed workers were significantly higher than that of patch-test(-)group, formaldehyde-exposed workers without skin lesions and non-exposed controls(P<0.05). The proportions of circulating CD3+CD8-IL17+ and CD3+CD8-IL22+cells from patch-test(-)group and formaldehyde-exposed workers without skin lesions were also higher than that of non-exposed controls(P<0.05). But there was no significant difference between patch-test(-)group and formaldehyde-exposed workers without skin lesions(P>0.05). Peripheral CD3+CD8+IL17+and CD3+CD8+IL22+cells were also detected in spite of small amounts. The percentages of CD3+CD8+IL17+and CD3+CD8+IL22+ cells inperipheral blood from patch-test(+)formaldehyde-exposed workers were enhanced significantly, compared to patch-test(-)group, formaldehyde-exposed workers without skin lesions and non-exposed controls(P<0.05). The proportions of circulating CD3+CD8+IL17+ and CD3+CD8+IL22+ cells from patch-test(-)group and formaldehyde-exposed workers without skin lesions were significantly higher than that of non-exposed controls(P<0.05). But there was no significant difference between patch-test(-) group and formaldehyde-exposed workers without skin lesions(P>0.05). Conclusion: The proportions of circulating IL17+ and IL22+T cells(both CD8-and CD8+)are enhanced in formaldehyde-exposed workers at proposed OEL, possibly involved in the development of formaldehyde-induced OACD.The detection of IL17-and IL22-secreting cells combined with formaldehyde patch test help to screen the workers with allergy property and prevent OACD.


Assuntos
Dermatite Alérgica de Contato/sangue , Formaldeído/efeitos adversos , Interleucina-17/metabolismo , Interleucinas/metabolismo , Exposição Ocupacional/efeitos adversos , Testes do Emplastro , Dermatite Ocupacional/sangue , Humanos , Interleucina 22
4.
Zhonghua Yu Fang Yi Xue Za Zhi ; 46(9): 836-9, 2012 Sep.
Artigo em Chinês | MEDLINE | ID: mdl-23157890

RESUMO

OBJECTIVE: To detect the cytokines levels in serums of patients with trichloroethylene-induced hypersensitivity dermatitis and explore the effect biomarkers associated with this disease. METHODS: Twenty-two patients with TCE-induced hypersensitivity dermatitis, twenty-two healthy TCE-exposed workers from the same workshops with patients and twenty-two comparable unexposed controls were recruited in this study. Eight cytokines in serums from all subjects were detected using Liquid Suspended Biochip; the correlation among the eight cytokines including interleukin (IL)-1ß (IL-1ß), IL-5, IL-8, IL-10, interferon-γ (IFN-γ), tumor necrosis factor-α (TNF-α), macrophage chemoattractant protein-1 (MCP-1), macrophage inflammatory protein-1ß (MIP-1ß) and the correlation between IL-5 and eosinophil count were analyzed. RESULTS: The medians of levels of IL-1ß, IFN-γ, IL-5, IL-10, MCP-1, MIP-1ß, IL-8 among patients were 0.15, 80.13, 2.95, 6.45, 83.83, 1057.90, 440.22 pg/ml, respectively, which were higher than those among the TCE-exposed workers (0.09, 16.93, 0.11, 0.07, 28.75, 241.07, 28.26 pg/ml, respectively, all P values < 0.01) and unexposed controls (0.09, 3.14, 0.11, 0.07, 25.27, 209.64, 207.34 pg/ml, respectively, all P values < 0.01). The median of level of TNF-α among the patients was 13.26 pg/ml, which was significantly higher than that among TCE-exposed workers (4.87 pg/ml, P < 0.01) but not among unexposed controls; the median of level of IL-5 among the TCE-exposed workers was 0.11 pg/ml, which was significantly higher than that among the unexposed controls (0.11 pg/ml, P < 0.01). The median of levels of IL-8 among the unexposed controls was 207.34 pg/ml, which was significantly higher than that among the TCE-exposed workers (28.26 pg/ml, P < 0.01). In case group, except for correlation of TNF-α and IFN-γ, TNF-α and IL-5, the significant positive correlations were found among any two cytokines (r(IL-1ß,IFN-γ) = 0.500, r(IL-1ß,TNF-α) = 0.348, r(IL-1ß,MCP-1) = 0.537, r(IL-1ß,MIP-1ß) = 0.477, r(IL-1ß,IL-8) = 0.466, r(IL-1ß,IL-5) = 0.610, r(IL-1ß,IL-10) = 0.626, r(IFN-γ,MCP-1) = 0.460, r(IFN-γ,MIP-1ß) = 0.491, r(IFN-γ,IL-8) = 0.322, r(IFN-γ,IL-5) = 0.532, r(IFN-γ,IL-10) = 0.511, r(TNF-α,MCP-1) = 0.325, r(TNF-α,MIP-1ß) = 0.283, r(TNF-α,IL-8) = 0.430, r(TNF-α,IL-10) = 0.271, r(MCP-1,MIP-1ß) = 0.659, r(MCP-1,IL-8) = 0.526, r(MCP-1,IL-5) = 0.504, r(MCP-1,IL-10) = 0.614, r(MIP-1ß,IL-8) = 0.601, r(MIP-1ß,IL-5) = 0.451, r(MIP-1ß,IL-10) = 0.579, r(IL-8,IL-5) = 0.255, r(IL-8,IL-10) = 0.403, r(IL-5,IL-10) = 0.798, all P values < 0.05). The median of level of IL-5 among the patients with high eosinophils counts was 8.92 pg/ml, which was significantly higher than that among the patients with low eosinophils counts (1.04 pg/ml, P < 0.05). CONCLUSION: The abnormal production of IL-1ß, IFN-γ, TNF-α, IL-8, MCP-1, MIP-1ß, IL-5 and IL-10 was related with the pathogenesis of hypersensitivity dermatitis induced by TCE. These cytokines could be used as referential indexes in the early health surveillance and clinic disease treatment.


Assuntos
Dermatite Ocupacional/sangue , Dermatite Ocupacional/etiologia , Tricloroetileno/efeitos adversos , Adolescente , Adulto , Quimiocina CCL2/sangue , Quimiocina CCL4/sangue , Feminino , Humanos , Hipersensibilidade/sangue , Interferon gama/sangue , Interleucinas/sangue , Masculino , Fator de Necrose Tumoral alfa/sangue , Adulto Jovem
5.
East Mediterr Health J ; 16(4): 420-4, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20795427

RESUMO

Allergic contact dermatitis to cement is a delayed-type hypersensitivity reaction in which cytokines interferon-gamma (IEN-y) and vascular endothelial growth factor(VEGF) may be involved in persisting erythema and oedema. VEGF and IFN-gamma levels in serum and skin lesions were measured in 32 Egyptian building workers with chronic allergic contact dermatitis due to occupational exposure to cement and 20 healthy controls. Dermatitis patients had significantly higher levels of serum and lesional skin VEGF and IFN-gamma than controls. A significant positive correlation was found between tissue VEGF and the eczema area and severity index (EASI) score in dermatitis patients (r = 0.86). VEGF and IFN-gamma may play a role in the pathogenesis of cement allergic contact dermatitis.


Assuntos
Materiais de Construção/efeitos adversos , Dermatite Alérgica de Contato/patologia , Dermatite Ocupacional/patologia , Índice de Gravidade de Doença , Fator A de Crescimento do Endotélio Vascular/análise , Adolescente , Adulto , Biópsia por Agulha , Estudos de Casos e Controles , Doença Crônica , Dermatite Alérgica de Contato/sangue , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Dermatite Ocupacional/sangue , Dermatite Ocupacional/epidemiologia , Dermatite Ocupacional/etiologia , Regulação para Baixo/imunologia , Egito/epidemiologia , Ensaio de Imunoadsorção Enzimática , Humanos , Interferon-alfa/análise , Interferon-alfa/sangue , Interferon-alfa/imunologia , Masculino , Pessoa de Meia-Idade , Fator A de Crescimento do Endotélio Vascular/sangue , Fator A de Crescimento do Endotélio Vascular/imunologia
6.
Contact Dermatitis ; 57(5): 309-15, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17937745

RESUMO

BACKGROUND: Construction workers exposed to cement are known to suffer from occupational contact dermatitis because of chromate sensitization. It is not clear whether certain genotypes are associated with increased susceptibility of chromate sensitization in those workers regularly exposed to cement. OBJECTIVE: The objective of this study was to determine the genotypes predisposing workers to cement-induced contact dermatitis. METHODS: A total of 153 current cement workers who had regular contact with cement were telephone interviewed for skin problems in the past 12 months, work exposure, and personal protection. A dermatologist examined their skin and conducted patch test with common skin allergens. Blood samples were donated for genotypic determination by polymerase chain reaction-based assays for GST-T1, GST-M1 (null/non-null), tumour necrosis factor (TNF) alpha promoter-308G/A, and interleukin (IL) 4-590C/T. RESULT: High percentage of dermatitis was noted in the 153 workers examined, which was correlated with reported skin problems. By patch testing, construction workers had a high-prevalence rate (12%) of sensitivity to chromate. Sensitivity to chromate was significantly associated with TNF alpha promoter-308 heterozygous (GA) as compared with GG genotype (odds ratio 3.9, 95% confidence interval 1.1-13.2), as well as with GST-T1 null genotype (odds ratio 5.5, 95% confidence interval 1.4-36.2), but neither the GST-M1 nor the IL-4 genotypes. CONCLUSION: It is concluded that among workers frequently exposed to cement in Southern Taiwan, those with TNF alpha promoter-308 heterozygous (GA) genotype or GST-T1 null genotype had increased risk of chromate sensitization.


Assuntos
Dermatite Alérgica de Contato/genética , Dermatite Ocupacional/genética , Predisposição Genética para Doença , Glutationa Transferase/genética , Fator de Necrose Tumoral alfa/genética , Adulto , Idoso , Alérgenos/efeitos adversos , Povo Asiático/genética , Cromatos/efeitos adversos , Materiais de Construção/efeitos adversos , DNA/análise , Dermatite Alérgica de Contato/sangue , Dermatite Alérgica de Contato/epidemiologia , Dermatite Ocupacional/sangue , Dermatite Ocupacional/epidemiologia , Feminino , Genótipo , Humanos , Masculino , Pessoa de Meia-Idade , Testes do Emplastro , Reação em Cadeia da Polimerase , Inquéritos e Questionários , Taiwan/epidemiologia
7.
Contact Dermatitis ; 53(3): 125-9, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16128749

RESUMO

The present work was undertaken to study in hairdressers exposed to several irritants and allergens (prevalently hair-dyeing) and affected by hand contact dermatitis the possible correlation between exposure and direct-oxidative DNA damage, production of tumour necrosis factor alpha (TNFalpha) and allergic inflammatory disease. We evaluated in 19 hairdressers with hand contact dermatitis, 14 allergic contact dermatitis (ACD) and 5 irritant contact dermatitis (ICD) and in a selected control group TNFalpha serum levels by ELISA and direct-oxidative DNA damage by Fpg (formamido-pyrimidine-glycosylase)-modified Comet test on blood. Hairdressers were divided on the basis of number of hair-dyeing carried out weekly into 2 groups: low-exposure (<60 hair-dyeing/week) and high-exposure hairdressers (>or=60 hair-dyeing/week) that reflect also the exposure to other allergens and irritants and 2 different tasks (hairdressers and apprentice hairdressers, respectively). Serum levels of TNFalpha in hairdressers with ACD were significantly higher than controls with a correlation to exposure level. Significant DNA damage in ICD hairdressers with higher exposure as compared to controls was found. These findings suggest that occupational exposure can induce in hairdressers, particularly ICD, DNA damage, increase the TNFa levels particularly in ACD and induce allergic sensitization, suggesting a relationship between direct-oxidative DNA damage, TNFalpha production and allergic inflammatory disease.


Assuntos
Indústria da Beleza , Dano ao DNA , Dermatite Ocupacional/etiologia , Dermatoses da Mão/etiologia , Fator de Necrose Tumoral alfa/biossíntese , Adulto , Análise de Variância , Estudos de Casos e Controles , Ensaio Cometa , Dermatite Ocupacional/sangue , Feminino , Tinturas para Cabelo/efeitos adversos , Dermatoses da Mão/sangue , Humanos , Masculino
8.
Int Arch Occup Environ Health ; 72(8): 533-8, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10592006

RESUMO

OBJECTIVES: To assess the health effects of hexamethylenetetramine (HMT) on the airways and the skin of workers in the chemical industry. METHODS: A cross-sectional study was performed with 17 employees of a HMT-producing chemical plant and 16 control subjects from the plant. In addition, we examined 4 out of 5 subjects who had left the production for medical reasons during the last 10 years. Anamnestic data, total and specific IgE to four environmental allergens, lung function and bronchial responsiveness to methacholine were assessed by standard procedures. Skin prick tests (SPT) and patch tests were performed with known sensitizing substances and HMT 100 mg/ml and 2% pet and aq. RESULTS: A high number of exposed subjects and controls reported symptoms during the previous year (64.7% vs 68.8%), most of them were not related to work. Work-related symptoms and objective parameters did not show differences between groups. No sensitizations to HMT as assessed by SPT or patch tests were found. Among those who had left the HMT production for medical reasons, 2 former baggers showed sensitizations to HMT by patch tests. These reported eczema during exposure but lost symptoms after removal from exposure. Geometric mean HMT concentrations as assessed by personal sampling were 0.3 [95% confidence intervals (CI) 0.1; 0.9] mg/m(3) in shiftleaders and 0.6 (95% CI 0.3; 1.1) mg/m(3) in baggers. CONCLUSION: High exposures to HMT may cause allergic contact dermatitis. There was no evidence of an increased risk for occupational asthma at mean airborne HMT concentrations below 1 mg/m(3).


Assuntos
Poluentes Ocupacionais do Ar/efeitos adversos , Poluentes Ocupacionais do Ar/análise , Asma/induzido quimicamente , Dermatite Ocupacional/etiologia , Monitoramento Ambiental/métodos , Metenamina/efeitos adversos , Metenamina/análise , Doenças Profissionais/induzido quimicamente , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/análise , Adulto , Asma/sangue , Asma/diagnóstico , Estudos de Casos e Controles , Estudos Transversais , Dermatite Ocupacional/sangue , Dermatite Ocupacional/diagnóstico , Alemanha , Humanos , Imunoglobulina E/sangue , Indústrias , Masculino , Pessoa de Meia-Idade , Doenças Profissionais/sangue , Doenças Profissionais/diagnóstico , Plásticos , Borracha , Testes Cutâneos , Espirometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA