1.
Cochlear Implants Int ; 21(3): 153-159, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32160829

RESUMO

Objectives: To investigate the effect of fixed and adaptive microphone directionality on speech reception threshold (SRT) in noise when compared to omnidirectional mode in unilateral cochlear-implant (CI) use for three different CI systems.Methods: Twenty-four CI recipients with bilateral severe-to-profound hearing loss participated in the study. Eight recipients of each CI system were enrolled, and their SRT in noise was measured when the speech and noise signals were co-located in the front to serve as a baseline. The acute effect of different microphone directionalities on SRT in noise was measured with the noise emanating at 90° in the horizontal plane from the side of the CI sound processor (S0NCI).Results: When compared to the baseline condition, the individual data revealed fairly similar patterns within each CI system. In the S0NCI condition, the average improvement in SRT in noise for fixed and adaptive directionalities over the omnidirectional mode was statistically significant and ranged from 1.2 to 6.0 dB SNR and from 3.7 to 12.7 dB SNR depending on the CI system, respectively.Discussion: Directional microphones significantly improve SRT in noise for all three CI systems. However, relatively large differences were observed in the directional microphone efficacy between CI systems.


Assuntos
Implante Coclear/instrumentação , Implantes Cocleares , Surdez/psicologia , Desenho de Prótese/psicologia , Percepção da Fala/fisiologia , Adulto , Surdez/cirurgia , Feminino , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Ruído , Período Pós-Operatório , Teste do Limiar de Recepção da Fala
2.
Eur J Orthop Surg Traumatol ; 27(8): 1151-1155, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28184996

RESUMO

PURPOSE: To compare the patients ability to forget the artificial knee joint in everyday life who were randomized to be operated for mobile- or fixed-bearing total knee arthroplasty (TKA). METHODS: This single-center randomized controlled trial evaluated the 3-year follow-up of the cemented mobile- and fixed-bearing TKA from the same brand in a series of 41 patients. Clinical examination was during the pre-, 6-week, 6-month, 1-, 2- and 3-year follow-up containing multiple patient-reported outcome measures (PROMs) including the 12-item Forgotten Joint Score (FJS-12) at 3 years. Effect size was calculated for each PROM at 3-year follow-up to quantify the size of the difference between both bearings. RESULTS: At 3-year follow-up, general linear mixed model analysis showed that there were no significant or clinically relevant differences between the two groups for all outcome measures. Calculated effect sizes were small (<0.3) for all the PROMs except for the FJS-12; these were moderate (0.5). CONCLUSION: The results of this study demonstrate that joint awareness was slightly lower in patients operated with the MB TKA with comparable improved clinical outcome and PROMs at 3-year follow-up. Measuring joint awareness with the FJS-12 is useful and provides more stringent information at 3-year follow-up compared to other PROMs and should be the PROM of choice at each follow-up after TKA. LEVEL OF EVIDENCE: Level I, randomized controlled trial.


Assuntos
Artroplastia do Joelho/instrumentação , Conscientização , Prótese do Joelho/psicologia , Desenho de Prótese/psicologia , Idoso , Feminino , Seguimentos , Humanos , Articulação do Joelho , Masculino , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Período Pós-Operatório
3.
Ophthalmologe ; 113(2): 133-42, 2016 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-26160105

RESUMO

BACKGROUND: Ocular prosthetics make a decisive contribution to the functional, esthetic and psychosomatic rehabilitation of patients after ocular extirpation. OBJECTIVES: This article provides an overview of the fitting, daily care and complications of ocular prosthetics. METHODS: The study comprised a PubMed literature review and own clinical results. RESULTS: Ocular prosthetics made from cryolite glass or perspex can be manufactured and fitted 5-8 weeks after removal of the eye. During this period a conformer is placed within the conjunctival sac in order to prevent scar formation and shrinking of the socket. Artificial eyes can be worn continuously, only interrupted by a short but regular cleaning procedure. Artificial tears and lid hygiene improve the comfort of wearing. Glass prostheses have to be renewed every 1-2 years, while perspex prostheses need to be polished once a year. Complications, such as giant papillary conjunctivitis or blepharoconjunctivitis sicca are facilitated by poor fit, increased age and inappropriate care of the prosthetic device. In the case of socket shrinkage or anophthalmic socket syndrome, surgical interventions are needed to re-enable the use of an artificial eye. CONCLUSION: Adequate fitting, daily care of ocular prosthetics and therapeutic management of associated complications are mandatory for a durable functional, esthetic and psychosomatic rehabilitation after ocular extirpation.


Assuntos
Enucleação Ocular/psicologia , Enucleação Ocular/reabilitação , Olho Artificial/efeitos adversos , Olho Artificial/psicologia , Ajuste de Prótese/métodos , Ajuste de Prótese/psicologia , Análise de Falha de Equipamento , Olho Artificial/tendências , Alemanha , Humanos , Desenho de Prótese/psicologia , Falha de Prótese , Ajuste de Prótese/tendências , Resultado do Tratamento
5.
Eur J Cancer Care (Engl) ; 18(6): 556-68, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19489989

RESUMO

A good-quality external breast prosthesis and prosthesis-fitting service is integral to recovery post-mastectomy. However, this area of care has minimal information or research available. The aim of this study was to investigate women's experience of the provision, fitting, supply and use of breast prostheses in Ireland. Three national surveys were undertaken with women (n = 527), breast care nurses (BCNs) (n = 32) and retail prosthesis fitters (n = 12). The findings identified the importance of the prosthesis for shape, appearance to self, appearance to others, sense of well-being, self-confidence and femininity. Dissatisfaction with weight, comfort and movement of the prosthesis was identified. Cost and travel distance were found to influence the replacement of the prosthesis. Dissatisfaction emerged with the display and choice of products, and brochure availability at the prosthesis fitting. Women preferred to be fitted for the first silicone prosthesis by a BCN in a hospital setting whereas for the replacement prosthesis they preferred a trained fitter at a specialized prosthesis supplier. BCNs and retail fitters identified the need for service guidelines and increased availability of professional development opportunities in prosthesis-fitting. These findings contributed to the development of standards of care for breast prosthesis-fitting services to benefit women and to provide guidelines for those providing the service.


Assuntos
Neoplasias da Mama/reabilitação , Satisfação do Paciente , Próteses e Implantes/psicologia , Ajuste de Prótese/psicologia , Atividades Cotidianas , Adulto , Idoso , Neoplasias da Mama/economia , Neoplasias da Mama/psicologia , Efeitos Psicossociais da Doença , Feminino , Inquéritos Epidemiológicos , Humanos , Irlanda , Mastectomia/psicologia , Pessoa de Meia-Idade , Educação de Pacientes como Assunto , Cuidados Pós-Operatórios , Relações Profissional-Paciente , Próteses e Implantes/economia , Próteses e Implantes/provisão & distribuição , Desenho de Prótese/psicologia , Adulto Jovem
6.
Knee Surg Sports Traumatol Arthrosc ; 16(3): 297-304, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18157487

RESUMO

We investigated the level of patient knowledge and preferences over the currently controversial issues in TKA. One hundred patients who had decided to undergo TKA for advanced osteoarthritis were asked to complete a questionnaire inquiring their knowledge and preferences over three controversial issues: (1) computer assisted surgery (CAS), (2) minimal invasive surgery (MIS), and (3) ceramic femoral component. The patient preferences over the three issues were questioned again after they had been informed of advantages and disadvantages of each option using an explanatory document. Most (more than 75%) of the patients did not have sufficient knowledge and their knowledge was based on non-professional sources (more than 85%). Before the information was given, most (more than 80%) of the patients preferred a new option. After the information was provided, more patients preferred a standard option in the issues of CAS (60%) and MIS (88%). This study prompts health care providers to become more active in providing accurate information and to consider patients perspective in making decisions which will influence the benefits and risk of the patients.


Assuntos
Artroplastia do Joelho/métodos , Conhecimentos, Atitudes e Prática em Saúde , Satisfação do Paciente , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/psicologia , Coleta de Dados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Desenho de Prótese/psicologia , Cirurgia Assistida por Computador/métodos
7.
J Prosthet Dent ; 69(3): 289-92, 1993 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8445560

RESUMO

The use of tissue-integrated fixtures for the retention of an extraoral prosthesis has simplified the placement, removal, and cleaning of the prosthesis by the patient. Tissue evaluation, structural designs, and retention mechanisms, combined with patient compliance and the ability to perform hygiene around retentive substructures, has produced an array of new problems. Clinical and technical problems are presented with techniques used in their resolution.


Assuntos
Neoplasias Nasais/reabilitação , Nariz , Próteses e Implantes/efeitos adversos , Desenho de Prótese/efeitos adversos , Olho Artificial/reabilitação , Feminino , Humanos , Higiene , Inflamação/etiologia , Magnetismo , Masculino , Prótese Maxilofacial , Cooperação do Paciente , Desenho de Prótese/psicologia , Falha de Prótese , Autocuidado/efeitos adversos