Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 336
Filtrar
1.
BMJ Case Rep ; 17(5)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38782438

RESUMO

SummaryGiant cell tumours of bone are benign and locally aggressive tumours that usually occur in young adults and at the epiphysial locations after physeal closure. Occurrence outside of epiphysial locations and appearance in geriatric patients is rare. We report a case of a woman in her late 60s with a giant cell tumour of the mid-shaft of the right tibia. Extended curettage and biological reconstruction were performed with autologous double-barrel fibular struts and tri-cortical iliac crest bone grafting. At the 28-month follow-up examination, we noted full bony union at both ends with successful consolidation of the fibular struts, and importantly, no evidence of recurrence or other complications was observed.


Assuntos
Neoplasias Ósseas , Tumor de Células Gigantes do Osso , Tíbia , Humanos , Feminino , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Tíbia/patologia , Neoplasias Ósseas/cirurgia , Neoplasias Ósseas/patologia , Neoplasias Ósseas/diagnóstico por imagem , Tumor de Células Gigantes do Osso/cirurgia , Tumor de Células Gigantes do Osso/patologia , Tumor de Células Gigantes do Osso/diagnóstico por imagem , Curetagem , Transplante Ósseo/métodos , Pessoa de Meia-Idade , Ílio/diagnóstico por imagem , Fíbula/diagnóstico por imagem , Fíbula/patologia , Fíbula/cirurgia , Diáfises/cirurgia , Resultado do Tratamento
2.
Injury ; 55(6): 111516, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38604112

RESUMO

OBJECTIVES: The aim of this study was to compare the radiological and clinical results of femoral diaphyseal fractures operated in the lateral decubitus position with those operated in the supine position on a traction table and to detail the perioperative surgical technique. PATIENTS AND METHODS: Between October 2018 and January 2022, in this prospective, randomized, and single-blind comparative study, 75 patients diagnosed with adult femoral diaphyseal fractures to whom intramedullary nails were applied were operated in the lateral decubitus position without a traction table (Group 1, 37 patients) and in the supine position with a traction table (Group 2, 38 patients). Preoperative age, gender, fracture mechanism, fracture type, and surgical waiting times were determined. Perioperative anesthesia type, surgery preparation time, surgical time, number of fluoroscopy doses, amount of bleeding, and type of reduction were evaluated, and detailed observational descriptions of the surgical techniques were made. In the postoperative period, radiological evaluations were made with x-ray radiography and orthoroentgenogram, while in the clinical evaluation, hip-knee joint range of motion and rotational evaluation were made with the Craigs test. Follow-up periods were determined and complications noted. RESULTS: The average age was 32 in Group 1 and 28 in Group 2, the female/male ratio was 1:36 in Group 1 and 5:33 in Group 2, and the follow-up period was 18.2 months Group 1 and 21.7 months in Group 2. No significant difference was detected between the groups in terms of age, gender, fracture mechanism, fracture type, anesthesia type, surgical waiting time, and follow-up period (p > 0.05). Compared to Group 2, the shorter preparation time, surgical time, and number of fluoroscopy doses in Group 1 were found to be statistically significant (p < 0.05). The differences in the amount of bleeding and need for open reduction were not statistically significant between the groups (p > 0.05), and no statistical difference was found in joint range of motion and rotational evaluation in clinical evaluation in both groups (p > 0.05). There was no significant difference in terms of complications between groups. CONCLUSIONS: We found the lateral decubitus method without a traction table to be a safe and effective alternative to the supine method with a traction table in terms of the radiological and clinical results and that it also has the advantages of shortening the surgical time, reducing radiation exposure. LEVEL OF EVIDENCE: Level 1 prospective, randomized, single-blind controlled study.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Posicionamento do Paciente , Tração , Humanos , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/instrumentação , Feminino , Masculino , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/diagnóstico por imagem , Adulto , Estudos Prospectivos , Tração/métodos , Posicionamento do Paciente/métodos , Resultado do Tratamento , Método Simples-Cego , Amplitude de Movimento Articular , Pessoa de Meia-Idade , Diáfises/cirurgia , Diáfises/lesões , Decúbito Dorsal , Pinos Ortopédicos , Duração da Cirurgia , Adulto Jovem , Radiografia , Consolidação da Fratura/fisiologia
3.
J Feline Med Surg ; 26(2): 1098612X231214930, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38358307

RESUMO

OBJECTIVES: The objectives of this study were to report the complications in radial and ulnar diaphyseal fractures in cats and to compare the differences in outcome between single and dual bone internal fixation. METHODS: Medical records between 2004 and 2022 were searched retrospectively for cats with antebrachial diaphyseal fractures treated with internal bone-plate fixation. In total, 49 cases were included from six referral hospitals, including one teaching hospital. Patient information was collated, including fracture configuration, location, repair method and clinical outcome as assessed by veterinary physical examination, radiography and owner questionnaire. RESULTS: A total of 47 cats (mean age 4.2 years) were included. Fractures were located distally (24/49, 49%), proximally (13/49, 26.5%) and mid-diaphyseally (12/49, 24.5%). Dual bone fixation was used in 13/49 (26.5%) cases, with only 1/13 (7.7%) having major complications. By comparison, 4/36 (11.1%) of single plated fractures had major complications. Single bone fixation was 14.25 times more likely (95% confidence interval [CI] 2.07-97.99) to have a successful outcome (veterinarian-assigned score of 0) compared with dual bone fixation (P = 0.007). When evaluating owner-assessed outcomes, single bone fixation was 9.4 times more likely (95% CI 1.4-61.96) to have a successful outcome (owner score of 0) compared with dual bone fixation (P = 0.019). CONCLUSIONS AND RELEVANCE: Fractures that were repaired with single bone fixation had a greater chance of a better outcome. Although the difference was not significant, there was a higher major complication rate and a lower minor complication rate for cases treated with single bone fixation compared with dual bone fixation. The majority of fractures were located in the distal diaphysis. Comminution of the fracture and concurrent orthopaedic issues did not significantly affect the outcome. Further prospective studies with standardised follow-up, radiographic assessment, surgeon and implants are required to truly assess the difference between dual and single bone fixation.


Assuntos
Doenças do Gato , Fraturas Ósseas , Gatos , Animais , Estudos Retrospectivos , Diáfises/cirurgia , Estudos Prospectivos , Fraturas Ósseas/cirurgia , Fraturas Ósseas/veterinária , Fixação Interna de Fraturas/veterinária
4.
Orthopedics ; 47(2): e102-e105, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37921530

RESUMO

We describe a 36-year-old man with a long-standing diagnosis of ulnar fibrous dysplasia with associated fracture of the ulna. He presented with a growing and increasingly tender forearm mass and was diagnosed with adamantinoma of the ulna, for which he underwent wide resection of the ulnar diaphysis followed by reconstruction with a vascularized fibula autograft. This case serves to emphasize the importance of performing a stepwise workup for the diagnosis of osseous neoplasms even in cases with long-standing diagnoses. [Orthopedics. 2024;47(2):e102-e105.].


Assuntos
Adamantinoma , Neoplasias Ósseas , Procedimentos Ortopédicos , Masculino , Humanos , Adulto , Adamantinoma/diagnóstico por imagem , Adamantinoma/cirurgia , Fíbula/cirurgia , Fíbula/transplante , Diáfises/cirurgia , Ulna/diagnóstico por imagem , Ulna/cirurgia , Neoplasias Ósseas/cirurgia
5.
Arch Orthop Trauma Surg ; 144(2): 693-699, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37930359

RESUMO

INTRODUCTION: Humeral shaft fractures are common fractures of the diaphysis of the humerus. The aim of this study was to evaluate factors affecting the clinical outcomes of humeral nonunions surgically treated with open reduction and single- versus double-plate fixation with grafting. MATERIALS AND METHODS: A total of 31 patients with nonunion treated with single- or double-plate screw fixation with bone grafting were retrospectively analysed. The patients were divided into two groups according to the treatment method as Group 1 (single-plate, n = 14) and Group 2 (double-plate, n = 17). Data including demographic and clinical characteristics of the patients, initial and final treatment, type of nonunion and localisation, graft use, shortening, follow-up, time to union, Quick Disabilities of the Arm, Shoulder and Hand (Quick-DASH) scores, and patient-reported cosmetic outcomes were recorded. RESULTS: Of the patients, eight were males, and 23 were females, with a mean age of 47.6 ± 15.8 (range, 20-86) years. Initial treatment was conservative treatment (Sarmiento brace) in seven patients, plate fixation in 22 patients, and intramedullary nailing in two patients. The mean follow-up was 31.0 ± 16.9 months in Group 1 and 25.4 ± 15.6 months in Group 2. There was one nonunion in Group 1 and three in Group 2. There were no significant differences in the union rate and time to union (p = 0.378 and p = 0.262, respectively). The mean Quick-DASH scores and cosmetic results were similar between the groups (p = 0.423 and p = 0.165, respectively). Radial nerve palsy developed in three patients in Group 2, and all these patients recovered completely during follow-up. CONCLUSIONS: Although the double-plate fixation technique has similar clinical, radiological, and functional results to single-plate fixation, it is a more invasive and expensive technique with a longer operation time. Therefore, it should not be used as the first-line treatment option for all humeral shaft nonunion. Nevertheless, the double-plate technique may be preferred to achieve in cases requiring high stability, such as hypertrophic nonunion, osteopenia and comminuted fractures.


Assuntos
Fixação Intramedular de Fraturas , Fraturas não Consolidadas , Fraturas do Úmero , Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Diáfises/cirurgia , Estudos Retrospectivos , Fraturas não Consolidadas/cirurgia , Fraturas não Consolidadas/etiologia , Fixação Intramedular de Fraturas/métodos , Úmero , Fraturas do Úmero/cirurgia , Placas Ósseas , Resultado do Tratamento , Fixação Interna de Fraturas/métodos
6.
J Bone Joint Surg Am ; 106(5): 425-434, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38127807

RESUMO

BACKGROUND: Femoral diaphyseal reconstructions with metal prostheses have mediocre results because of high mechanical forces that result in eventual implant failure. Biological alternatives require prolonged restrictions on weight-bearing and have high rates of infection, nonunion, and fracture. A novel method of utilizing a vascularized fibula in combination with an intercalary prosthesis was developed to complement the immediate stability of the prosthesis with the long-term biological fixation of a vascularized fibular graft. METHODS: A prospectively maintained database was retrospectively reviewed to identify patients who underwent reconstruction of an oncological intercalary femoral defect using an intercalary prosthesis and an inline fibular free flap (FFF). They were compared with patients who underwent femoral reconstruction using an intercalary allograft and an FFF. RESULTS: Femoral reconstruction with an intercalary metal prosthesis and an FFF was performed in 8 patients, and reconstruction with an allograft and an FFF was performed in 16 patients. The mean follow-up was 5.3 years and 8.5 years, respectively (p = 0.02). In the bioprosthetic group, radiographic union of the fibula occurred in 7 (88%) of 8 patients, whereas in the allograft group, 13 (81%) of 16 patients had allograft union (p = 1.00) and all 16 patients had fibular union (p = 0.33). The mean time to fibular union in the bioprosthetic group was 9.0 months, whereas in the allograft group, the mean time to allograft union was 15.3 months (p = 0.03) and the mean time to fibular union was 12.5 months (p = 0.42). Unrestricted weight-bearing occurred at a mean of 3.7 months in the prosthesis group and 16.5 months in the allograft group (p < 0.01). Complications were observed in 2 (25%) of 8 patients in the prosthesis group and in 13 (81%) of 16 patients in the allograft group (p = 0.02). Neither chemotherapy nor radiation affected fibular or allograft union rates. Musculoskeletal Tumor Society scores did not differ significantly between the groups (mean, 26 versus 28; p = 0.10). CONCLUSIONS: Bioprosthetic intercalary femoral reconstruction with a metal prosthesis and an FFF resulted in earlier weight-bearing, a shorter time to union, fewer operations needed for union, and lower complication rates than reconstruction with an allograft and an FFF. LEVEL OF EVIDENCE: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Membros Artificiais , Neoplasias Ósseas , Retalhos de Tecido Biológico , Humanos , Fíbula/transplante , Retalhos de Tecido Biológico/patologia , Estudos Retrospectivos , Diáfises/cirurgia , Diáfises/patologia , Neoplasias Ósseas/cirurgia , Transplante Ósseo/métodos , Resultado do Tratamento
7.
Ortop Traumatol Rehabil ; 25(3): 143-147, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-38078350

RESUMO

BACKGROUND: We aim to compare the preoperative planning radiographs of 50 patients in whom both a short stem and its homonymous standard version were programmed, focusing on the preservation of the neck and the invasion of the femoral shaft. The secondary objective was to evaluate the 50 preoperative radiographs with the 50 postoperative radiographs in which the short stem was implanted, measuring the real invasion of the diaphysis and the real preservation of the femoral neck. MATERIAL AND METHODS: We measured cut level at the femoral neck and diaphyseal invasion in 50 preoperative x-rays where an Alteon Neck Preserving Stem (ANPS) was templated and we compared it with 50 preoperative x-rays where an Alteon Taper Wedge Stem (ATWS) was templated. After surgery, we compared both parameters previously measured in the preoperative x-rays with the 50 postoperative radiographs where the short stem was implanted obtaining the real bone preservation at the femoral neck and the real diaphyseal invasion length. RESULTS: For templating comparison, mean bone preservation at the femoral neck was 14.87mm (SD 3.64) for the ANPS group and 9.94mm (SD 8.39) for the ATWS group (p <0.001). The mean diaphyseal bone invasion was 47.21mm (SD 5.89) and 76.77mm (SD 8.39) for ANPS and ATWS respectively (p <0.001). After surgery, the mean postoperative bone preservation at the femoral neck was 15.08mm (SD 3.1) with a mean of 0.17mm (SD 0.51) more preservation in the preoperative group. CONCLUSION: 1. ANPS allow bone preservation with limited diaphyseal invasion when compared with his homonymous ATWS in the preoperative templates. 2. ANPS showed a good correlation between preoperative radiographs and real bone preservation of the femoral neck and invasion of the femoral shaft.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/cirurgia , Diáfises/diagnóstico por imagem , Diáfises/cirurgia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Estudos Retrospectivos
8.
Orthop Surg ; 15(12): 3223-3230, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37880202

RESUMO

OBJECTIVE: Although mini-plate fixation is an attractive treatment option for distal radius metaphyseal diaphysis junction (DRMDJ) fractures in children, the benefits of minimally invasive fixation (MIF) with pre-bent elastic stable intramedullary nails (MIF) remain underexplored. Therefore, this study aimed to evaluate the clinical efficacy of MIF administration in children with DRMDJ fractures. METHODS: This retrospective study enrolled 40 patients with DRMDJ fractures who underwent MIF or mini-plate fixation from January 2016 to January 2021. Radiographic parameters, such as palmar inclination and ulnar deflection angle, were examined postoperatively to assess the anatomical reduction of the wrist joint. Clinical outcomes, including the range of wrist flexion and back extension, were examined to analyze the recovery of the wrist range of motion. Additionally, the Gartland-Werley scoring system was used to assess the recovery status of wrist function and healing condition. The student t-test and χ2 test were used to compare differences among groups. RESULTS: All included patients successfully underwent the operation and were followed up for 12-24 months. Patients in the MIF group had a smaller surgical incision length (0.49 ± 0.06 cm) compared to those in the mini-plate fixation group (4.41 ± 0.73 cm) (t = 22.438, p = 0.000). Palmar inclination and ulnar deflection were within the normal range in patients of both groups, and the fractures were successfully anatomically reduced. Moreover, wrist flexion and back extension in the MIF group and mini-plate group were (72.50° ± 0.64° vs. 70.18° ± 0.56°) and (59.55° ± 1.75° vs. 60.04° ± 1.37°), and differences were statistically significant (t = 2.708, p = 0.010 and t = 0.885, p = 0.382, respectively). Furthermore, MIF treatment resulted in a higher proportion of excellent Gartland-Werley scores (94.44%) than mini-plate fixation (86.36%) (p = 0.390). In addition, one case in the mini-plate fixation group experienced re-fracture following the removal of the internal fixation, and the fracture healed after reduction and cast fixation. All patients achieved satisfactory bone healing without other complications. CONCLUSION: Compared with mini-plate fixation, MIF has the advantages of small incision length, superior range of motion of thr wrist joint, and better maintenance of the physiological radian, providing a promising approach for clinical and surgical treatment of DRMDJ fractures.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Rádio , Humanos , Criança , Diáfises/cirurgia , Estudos Retrospectivos , Rádio (Anatomia) , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Fixação Intramedular de Fraturas/métodos , Fixação Interna de Fraturas/métodos , Resultado do Tratamento , Placas Ósseas , Amplitude de Movimento Articular
9.
Jt Dis Relat Surg ; 34(2): 374-380, 2023 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-37462641

RESUMO

OBJECTIVES: This study aims to compare the clinical and radiological results of intramedullary nailing and plating, which are both techniques utilized frequently in the surgical treatment of isolated fractures of the distal third of the ulna diaphysis. PATIENTS AND METHODS: Between January 2010 and December 2016, a total of 54 patients (34 males, 20 females; mean age: 37.8±7.4 years; range, 22 to 56 years) with isolated fractures of the distal third of the ulna diaphysis were retrospectively analyzed. The patients were divided into those treated with locking plates (Plating group, n=25) and those treated with intramedullary nailing (IMN group, n=29). The operating time and clinical and radiological results were compared between the groups. RESULTS: The median follow-up time was 93 (range, 84.5 to 99.5) months in the Pg and 86 (range, 80 to 97) months in the IMNg (p=0.179). No significant difference was observed between the groups in respect of age, sex, trauma mechanism, fracture classification, smoking status, and time from trauma to surgery. The median operating time was 46 min in the Pg and 33 min in the IMNg (p<0.001). No significant difference was found in the postoperative length of stay in hospital, reduction quality, infection rates, clinical results, radiological results, and the Quick Disabilities of the Arm, Shoulder, and Hand (Quick DASH) score between the groups. Implant removal was only needed in the locking plate group (p=0.007). CONCLUSION: In the surgical treatment of isolated fractures of the distal third of the ulna diaphysis, locked IMN seems to be a good alternative to the plate method with a shorter operating time and less need for implant removal.


Assuntos
Fixação Intramedular de Fraturas , Fraturas Ósseas , Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Fixação Intramedular de Fraturas/métodos , Diáfises/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Consolidação da Fratura , Pinos Ortopédicos , Ulna/diagnóstico por imagem , Ulna/cirurgia
10.
Clin Orthop Relat Res ; 481(11): 2200-2210, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37185204

RESUMO

BACKGROUND: Large metastatic lesions of the diaphysis can cause considerable pain and result in difficult surgical challenges. Resection and cemented intercalary endoprosthetic reconstruction offer one solution to the problem, but it is an extensive operation that might not be tolerated well by a debilitated patient. The risk of aseptic loosening and revision after intercalary endoprosthetic replacement has varied in previous reports, which have not examined the risk of revision in the context of patient survival. QUESTIONS/PURPOSES: (1) In a small case series from one institution, what is the survivorship of patients after cemented intercalary endoprosthetic replacement for diaphyseal metastasis, and what is the cumulative incidence of revision for any reason? (2) What are the complications associated with cemented intercalary reconstruction? (3) What is the functional outcome after the procedure as assessed by the MSTS93 score? METHODS: We retrospectively studied 19 patients with diaphyseal long bone metastases who were treated with resection and cemented intercalary endoprosthetic reconstruction by five participating surgeons at one referral center from 2006 to 2017. There were 11 men and eight women with a median age of 59 years (range 46 to 80 years). The minimum follow-up required for this series was 12 months; however, patients who reached an endpoint (death, radiographic loosening, or implant revision) before that time were included. One of these 19 patients was lost to follow-up but was not known to have died. The median follow-up was 24 months (range 0 to 116 months). Eight of the 19 patients presented with pathologic fractures. Ten of 19 lesions involved the femur, and nine of 19 were in the humerus. The most common pathologic finding was renal cell carcinoma (in 10 of 19). Survival estimates of the patients were calculated using the Kaplan-Meier method. A competing risks estimator was used to evaluate implant survival, using death of the patient as the competing risk. We also estimated the cumulative incidence of aseptic loosening in a competing risk analysis. Radiographs were analyzed for radiolucency at the bone-cement-implant interfaces, fracture, integrity of the cement mantle, and component position stability. Complications were assessed using record review that was performed by an individual who was not involved in the initial care of the patients. Functional outcomes were assessed using the MSTS93 scoring system. RESULTS: Patient survivorship was 68% (95% CI 50% to 93%) at 1 year, 53% (95% CI 34% to 81%) at 2 years, and 14% (95% CI 4% to 49%) at 5 years; the median patient survival time after reconstruction was 25 months (range 0 to 116 months). In the competing risk analysis, using death as the competing risk, the cumulative incidence of implant revision was 11% (95% CI 2% to 29%) at 1 year and 16% (95% CI 4% to 36%) at 5 years after surgery; however, the cumulative incidence of aseptic loosening (with death as a competing risk) was 22% (95% CI 6% to 43%) at 1 year and 33% (95% CI 13% to 55%) at 5 years after surgery. Other complications included one patient who died postoperatively of cardiac arrest, one patient with delayed wound healing, two patients with bone recurrence, and one patient who experienced local soft tissue recurrence that was excised without implant revision. Total MSTS93 scores improved from a mean of 12.6 ± 8.1 (42% ± 27%) preoperatively to 21.5 ± 5.0 (72% ± 17%) at 3 months postoperatively (p < 0.001) and 21.6 ± 8.5 (72% ± 28%) at 2 years postoperatively (p = 0.98; 3 months versus 2 years). CONCLUSION: Resection of diaphyseal metastases with intercalary reconstruction can provide stability and short-term improvement in function for patients with advanced metastatic disease and extensive cortical destruction. Aseptic loosening is a concern, particularly in the humerus; however, the competing risk analysis suggests the procedure is adequate for most patients, because many in this series died of disease without undergoing revision. LEVEL OF EVIDENCE: Level IV, therapeutic study .


Assuntos
Neoplasias Ósseas , Diáfises , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Diáfises/cirurgia , Diáfises/patologia , Estudos Retrospectivos , Fatores de Risco , Reoperação , Resultado do Tratamento , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Fêmur/patologia , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/cirurgia , Úmero/diagnóstico por imagem , Úmero/cirurgia , Úmero/patologia
11.
J Arthroplasty ; 38(6S): S302-S307, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37023912

RESUMO

BACKGROUND: A revision total knee arthroplasty must control limb alignment, often to address the cause of failure. Press-fit stems that engage the diaphysis with cement restricted to the metaphysis constitute one fixation technique. These long stems restrict coronal alignment of the prosthesis and as a result reduce the likelihood of extreme malposition. For the same reasons, long stems can make it difficult to manipulate alignment and achieve a specific coronal alignment angle. Nevertheless, femoral stems with a tight diaphyseal fit may still occupy a small range of varus-valgus positions due to the conical distal femoral metaphysis. Pulling the reamer toward the lateral endosteum increases femoral component coronal alignment toward a valgus direction and pushing the reamer medially increases alignment in a more varus direction. A straight stem, in combination with a medially directed reaming, would result in a femoral component that overhangs medially, but an offset stem can recenter the femoral component and maintain the desired alignment. We hypothesized that diaphyseal fit plus this reaming technique can control limb coronal alignment and provide fixation. METHODS: This was a retrospective clinical and long-leg radiographic study of consecutive revision total knee arthroplasties with minimum 2-year follow-up. Outcomes were correlated with New Zealand Joint Registry data to identify rerevisions of 111 consecutive revision knee arthroplasties, 92 after exclusions, at a minimum 2-year (range, 2 to 10) follow-up. RESULTS: Mean femoral and tibial canal fill exceeded 91% on antero-posterior and lateral radiographs. The mean hip-knee-ankle angle was 179.6o (174.9-184.0) with 80% within ± 3o of neutral. The hip-ankle axis crossed the central Kennedy zone in 76.5% of cases and the other 24.6% crossed the inner medial and inner lateral zones. Tibial components: 99.0% ± 3o. Femoral components: 89.5% within ± 3o. There were 5 knees that failed due to infection, 3 from femoral loosening, and 1 due to recurvatum instability from polio. CONCLUSIONS: This study describes a surgical plan and technique for achieving target coronal alignment with press-fit diaphyseal fixation. It is the only series of revision knee arthroplasties with diaphyseal press-fit stems to report canal fill in 2 planes and coronal alignment on full-length radiographs.


Assuntos
Artroplastia do Joelho , Articulação do Joelho , Prótese do Joelho , Humanos , Artroplastia do Joelho/métodos , Diáfises/cirurgia , Articulação do Joelho/cirurgia , Desenho de Prótese , Reoperação/métodos , Estudos Retrospectivos
12.
Eur J Orthop Surg Traumatol ; 33(6): 2663-2666, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36788165

RESUMO

This instructional review presents the literature and guidelines relevant to the classification, management and prognosis of paediatric tibial shaft fractures at a level appropriate for the FRCS exit examination in Trauma and Orthopaedic surgery.


Assuntos
Fixação Intramedular de Fraturas , Procedimentos Ortopédicos , Ortopedia , Fraturas da Tíbia , Humanos , Criança , Fraturas da Tíbia/diagnóstico , Fraturas da Tíbia/cirurgia , Prognóstico , Diáfises/cirurgia , Estudos Retrospectivos
13.
BMC Musculoskelet Disord ; 23(1): 852, 2022 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-36076197

RESUMO

BACKGROUND: Hip-preserved reconstruction for patients with ultrashort proximal femur segments following extensive femoral diaphyseal tumor resection is a formidable undertaking. A customized intercalary prosthesis with a rhino horn-designed uncemented stem was developed for the reconstruction of these extensive skeletal defects. METHODS: This study was designed to analyze and compare the differences in the biomechanical behavior between the normal femur and the femur with diaphyseal defects reconstructed by an intercalary prosthesis with different stems. The biomechanical behavior under physiological loading conditions is analyzed using the healthy femur as the reference. Five three-dimensional finite element models (healthy, customized intercalary prosthesis with four different stems implemented, respectively) were developed, together with a clinical follow-up of 12 patients who underwent intercalary femoral replacement. RESULTS: The biomechanical results showed that normal-like stress and displacement distribution patterns were observed in the remaining proximal femur segments after reconstructions with the rhino horn-designed uncemented stems, compared with the straight stem. Stem A showed better biomechanical performance, whereas the fixation system with Stem B was relatively unstable. The clinical results were consistent with the FEA results. After a mean follow-up period of 32.33 ± 9.12 months, osteointegration and satisfactory clinical outcomes were observed in all patients. Aseptic loosening (asymptomatic) occurred in one patient reconstructed by Stem B; there were no other postoperative complications in the remaining 11 patients. CONCLUSION: The rhino horn-designed uncemented stem is outstanding in precise shape matching and osseointegration. This novel prosthesis design may be beneficial in decreasing the risk of mechanical failure and aseptic loosening, especially when Stem A is used. Therefore, the customized intercalary prosthesis with this rhino horn-designed uncemented stem might be a reasonable alternative for the reconstruction of SSPF following extensive tumor resection.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Neoplasias , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Diáfises/cirurgia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Desenho de Prótese , Falha de Prótese , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Resultado do Tratamento
14.
J Feline Med Surg ; 24(7): 662-674, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35775308

RESUMO

PRACTICAL RELEVANCE: Cats frequently present with diaphyseal fractures, which require treatment in order to achieve a good return to function. These fractures often occur due to significant trauma; for example, as a result of road traffic accidents, high-rise syndrome and dog bite wounds. The first priority is to ensure the patient is systemically well before embarking on any specific surgical treatment of a fracture. CLINICAL CHALLENGES: Surgical management of diaphyseal fractures can be challenging due to the surgical approach for some bones being technically demanding, for example because of the presence of important neurovascular structures, and the small size of feline bones, which limits the choice of implant size and strength. Further, it may be difficult to visualise fracture alignment when using minimally invasive techniques, although the use of intraoperative fluoroscopy can aid with this, and malalignment can be common for some fracture repairs, particularly in cases where anatomical reconstruction is not possible. AIMS: This review focuses on diaphyseal long bone fractures and aims to assist decision-making, with an overview of the management and treatment options available. EVIDENCE BASE: Many textbooks and original articles have been published on aspects of managing fractures in small animals. The authors also provide recommendations based upon their own clinical experience.


Assuntos
Doenças do Gato , Doenças do Cão , Fraturas Ósseas , Animais , Placas Ósseas/veterinária , Doenças do Gato/cirurgia , Gatos , Diáfises/lesões , Diáfises/cirurgia , Cães , Fluoroscopia , Fraturas Ósseas/cirurgia , Fraturas Ósseas/veterinária
15.
Sci Rep ; 12(1): 9098, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35650218

RESUMO

To understand the potential and limitations of the different available surgical techniques used to treat large, long-bone diaphyseal defects by focusing on union, complication, re-intervention, and failure rates, summarizing the pros and cons of each technique. A literature search was performed on PubMed, Web of Science, and Cochrane databases up to March 16th, 2022; Inclusion criteria were clinical studies written in English, of any level of evidence, with more than five patients, describing the treatment of diaphyseal bone defects. The primary outcome was the analysis of results in terms of primary union, complication, reintervention, and failure rate of the four major groups of techniques: bone allograft and autograft, bone transport, vascularized and non-vascularized fibular graft, and endoprosthesis. The statistical analysis was carried out according to Neyeloff et al., and the Mantel-Haenszel method was used to provide pooled rates across the studies. The influence of the various techniques on union rates, complication rates, and reintervention rates was assessed by a z test on the pooled rates with their corresponding 95% CIs. Assessment of risk of bias and quality of evidence was based on Downs and Black's "Checklist for Measuring Quality" and Rob 2.0 tool. Certainty of yielded evidence was evaluated with the GRADE system. Seventy-four articles were included on 1781 patients treated for the reconstruction of diaphyseal bone defects, 1496 cases in the inferior limb, and 285 in the upper limb, with trauma being the main cause of bone defect. The meta-analysis identified different outcomes in terms of results and risks. Primary union, complications, and reinterventions were 75%, 26% and 23% for bone allografts and autografts, 91%, 62% and 19% for the bone transport group, and 78%, 38% and 23% for fibular grafts; mean time to union was between 7.8 and 8.9 months in all these groups. Results varied according to the different aetiologies, endoprosthesis was the best solution for tumour, although with a 22% failure rate, while trauma presented a more composite outcome, with fibular grafts providing a faster time to union (6.9 months), while cancellous and cortical-cancellous grafts caused less complications, reinterventions, and failures. The literature about this topic has overall limited quality. However, important conclusions can be made: Many options are available to treat critical-size defects of the diaphysis, but no one appears to be an optimal solution in terms of a safe, satisfactory, and long-lasting outcome. Regardless of the bone defect cause, bone transport techniques showed a better primary union rate, but bone allograft and autograft had fewer complication, reintervention, and failure rates than the other techniques. The specific lesion aetiology represents a critical aspect influencing potential and limitations and therefore the choice of the most suitable technique to address the challenging large diaphyseal defects.


Assuntos
Diáfises , Procedimentos de Cirurgia Plástica , Autoenxertos , Transplante Ósseo/efeitos adversos , Transplante Ósseo/métodos , Diáfises/cirurgia , Fíbula/cirurgia , Humanos , Procedimentos de Cirurgia Plástica/métodos
16.
Clin Orthop Surg ; 14(2): 178-183, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35685979

RESUMO

Background: Plate fixation for atypical femoral fractures has shown high failure rates compared to intramedullary nail fixation. The aim of this study was to evaluate the radiological results of patients treated with a plate and screws for atypical fractures of the femoral diaphysis. Methods: This study was conducted retrospectively on 16 patients who had undergone internal fixation using plates for treatment of atypical femoral complete fractures from 2007 to 2015. Nine patients were treated with lag screws and short plates while 7 patients were treated with position screws and long plates, which covered the whole femur. Radiologic evaluation was performed on all patients. Complications were also evaluated. Results: Bone union was achieved in all patients and the average bone union time was 17.7 weeks (range, 14-28 weeks). There was no correlation between the preoperative use of a bisphosphonate, plate length, postoperative teriparatide use, and the time to bone union. Regarding complications, 2 cases of complete fractures and 1 impending fracture occurred at the end of short plates. Conclusions: Satisfactory results were obtained with use of plates for patients with atypical femoral complete diaphyseal fractures, in whom intramedullary nails could not be applied due to severe bowing. In particular, it seemed advantageous compared with intramedullary nail fixation in that it could maintain the leg length through anatomical reduction and prevent iatrogenic fracture.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Pinos Ortopédicos , Placas Ósseas , Diáfises/diagnóstico por imagem , Diáfises/cirurgia , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fêmur , Fixação Interna de Fraturas/métodos , Fixação Intramedular de Fraturas/métodos , Humanos , Estudos Retrospectivos
17.
Curr Med Imaging ; 18(14): 1503-1509, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35761495

RESUMO

BACKGROUND: It is important for orthopedic surgeons to follow the union of the fracture after surgery. This becomes even more important after nonunion surgery. The radiological union scale is popular in the follow-up of unions. However, the intraobserver and interobserver agreement of this scale in humeral nonunion surgery is still not found in the literature. OBJECTIVE: This study aimed to reveal the intra/interobserver agreement of the Radiographic Union scale (RHUM) for the humerus as well as the relationship between this agreement, plate placement characteristics, and the number of plates in cases where plates were used for surgical treatment of humeral diaphysis nonunion. MATERIALS AND METHODS: Twenty patients who received surgical treatment for aseptic humeral nonunion at our hospital between 2010-2019 were studied retrospectively. According to RHUM, two observers scored the patients' anteroposterior and lateral radiographs in the postoperative 12th week. The data obtained were statistically analyzed. RESULTS: The mean age was 52.05±15.88 years. While a single plate was used in 14 cases, a double plate was used in 6 cases. Interobserver agreement was fair-moderate. The interobserver agreement values of the single plate group were significantly higher than those of the double plate group (p<0.05). Interobserver agreement in cases with a lateral plate was significantly higher than in the group where the lateral + posterior plate was applied (p:0.01). CONCLUSION: In humeral diaphyseal fracture nonunion cases, the number and location of the plate following surgery negatively impact the evaluation of RHUM scores. Given the importance of the union's follow-up and the decision to proceed with additional treatment in these cases, it may be necessary to develop a new method for determining and monitoring the union if a plate was used in the surgical treatment of humeral nonunion.


Assuntos
Diáfises , Fraturas do Úmero , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Diáfises/diagnóstico por imagem , Diáfises/cirurgia , Variações Dependentes do Observador , Estudos Retrospectivos , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/cirurgia , Úmero/diagnóstico por imagem , Úmero/cirurgia
18.
Curr Oncol ; 29(5): 3519-3530, 2022 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-35621674

RESUMO

BACKGROUND: The purpose of this study was to evaluate the implant survival, functional score and complications of intercalary endoprostheses implanted for metastatic involvement of the femoral and humeral diaphysis. METHODS: The selected group covered patients with bone metastasis who were surgically treated with an intercalary endoprosthesis between 2012 and 2021. The functional outcome was evaluated with the Musculoskeletal Tumor Society (MSTS) scoring system, and complications were evaluated by using the failure classification for prosthetics designed by Henderson. RESULTS: The mean follow-up was 29.8 months. In our group of 25 patients with 27 intercalary endoprostheses (18 femurs, 9 humeri), there were 7 implant-related complications (25.9%), which were more common on the humerus (4 cases, 44.4%) than on the femur (3 cases, 16.7%). Only type II failure-aseptic loosening (5 cases, 18.5%)-and type III failure-structural failure (2 cases, 7.4%)-occurred. There was a significantly higher risk of aseptic loosening of the endoprosthesis in the humerus compared with that in the femur (odds ratio 13.79, 95% confidence interval 1.22-151.05, p = 0.0297). The overall cumulative implant survival was 92% 1 year after surgery and 72% 5 years after surgery. The average MSTS score was 82%. The MSTS score was significantly lower (p = 0.008) in the humerus (75.9%) than in the femur (84.8%). CONCLUSIONS: The resection of bone metastases and replacement with intercalary endoprosthesis has excellent immediate functional results with an acceptable level of complications in prognostically favourable patients.


Assuntos
Neoplasias Ósseas , Neoplasias Femorais , Neoplasias Ósseas/cirurgia , Diáfises/cirurgia , Neoplasias Femorais/cirurgia , Fêmur/cirurgia , Humanos , Úmero/cirurgia , Complicações Pós-Operatórias , Próteses e Implantes
19.
BMC Musculoskelet Disord ; 23(1): 96, 2022 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-35090422

RESUMO

BACKGROUND: Most fractures in children are fractures of the upper extremity. Proximal and diaphyseal humeral fractures account for a minority of these fractures. To our knowledge, few previous reports address these fractures. This study aimed to describe the epidemiology and current treatment of proximal and diaphyseal humeral fractures by using the Swedish Fracture Register (SFR). METHODS: In this nationwide observational study from the SFR we analysed data on patient characteristics, injury mechanism, fracture classification and treatment. We included patients aged < 16 years at time of injury with proximal or diaphyseal humeral fracture registered in 2015-2019. RESULTS: 1996 (1696 proximal and 300 diaphyseal) fractures were registered. Proximal fractures were more frequent in girls whereas diaphyseal fractures were more frequent in boys. The median age at fracture was 10 years in both fracture types but patient's age was more widespread in diaphyseal fracture (IQR 5-13 compared to IQR 7-12 in proximal). In both sexes, the most registered injury mechanism was fall. Horse-riding was a common mechanism of injury in girls, whereas ice-skating and skiing were common mechanisms in boys. Most proximal fractures were metaphyseal fractures. Most diaphyseal fractures were simple transverse or oblique/spiral fractures. The majority of fractures were treated non-surgically (92% of proximal and 80% of diaphyseal fractures). The treatment method was not associated with the patient's sex. Surgery was more often performed in adolescents. The most common surgical methods were K-wire and cerclage fixation in proximal fracture and intramedullary nailing in diaphyseal fracture. CONCLUSION: Following falls, we found sex-specific sport activities to cause most proximal and diaphyseal paediatric fractures. Further studies on prophylactic efforts in these activities are needed to investigate whether these fractures are preventable. The majority of the fractures were treated non-surgically, although surgical treatment increased with increasing age in both sexes. TRIAL REGISTRATION: Not applicable. The present study is a register-based cohort study. No health care intervention had been undertaken.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Úmero , Adolescente , Animais , Criança , Estudos de Coortes , Diáfises/diagnóstico por imagem , Diáfises/cirurgia , Feminino , Cavalos , Humanos , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/epidemiologia , Fraturas do Úmero/cirurgia , Masculino , Suécia/epidemiologia
20.
Arch Orthop Trauma Surg ; 142(10): 2677-2683, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34244873

RESUMO

INTRODUCTION: Subtrochanteric atypical femoral fractures (AFFs) usually require long cephalomedullary or reconstruction nailing to achieve satisfactory healing. Recently, this type of nailing has also been recommended to fix diaphyseal AFFs and prevent fragility fractures around the proximal femur, although standard antegrade nailing seems sufficient from a biomechanical perspective. This study aimed to compare treatment outcomes and complications between reconstruction and standard nailing for diaphyseal AFFs. MATERIALS AND METHODS: A retrospective comparative study of 48 female patients with diaphyseal AFFs who underwent surgical treatment with either reconstruction or standard nailing was conducted. The reconstruction nailing group comprised 23 patients with a mean age of 74.4 years and included 16 complete and 7 incomplete AFFs. The mean follow-up period was 30 months. The standard nailing group comprised 25 patients with a mean age of 71.1 years and included 16 complete and 9 incomplete AFFs. The mean follow-up period was 57.8 months. The healing rate, time to union, and complications were analyzed and compared between the two groups. RESULTS: Bony union was achieved in all 23 cases (100%) of the reconstruction nailing group by a mean of 19.3 weeks postoperative. In the standard nailing group, 23 of 25 cases healed (92%) by a mean of 16 weeks postoperative. The standard nailing group included two delayed fragility fractures of the femoral neck (5 and 10 years after the initial surgery), four cases of newly developed subtrochanteric AFFs at the distal screw of the proximal interlocking screws of the nail (one complete and three incomplete fractures), and two cases of nonunion. Complications only occurred in the standard nailing group (p = 0.01, Fisher's exact test). CONCLUSIONS: In diaphyseal AFFs, reconstruction nailing may achieve a satisfactory outcome and can also decrease delayed peri-implant fragility fractures of the hip, newly developed subtrochanteric AFFs, and nonunion.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Fraturas do Quadril , Idoso , Pinos Ortopédicos , Diáfises/cirurgia , Feminino , Fraturas do Fêmur/cirurgia , Fraturas do Quadril/cirurgia , Humanos , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA