Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 582
Filtrar
1.
Eur J Contracept Reprod Health Care ; 29(3): 109-114, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38666336

RESUMO

OBJECTIVE: To examine the prevalence of infections with high-risk human papillomavirus (HPV) and cervical dysplasia, and the clearance rate of HPV infections, in users of different kinds of intrauterine devices (IUDs) and other contraceptive methods. METHODS: A cross-sectional register-based study including 16,181 women aged 30-49 years participating in the screening programme for cervical cancer in a Swedish County in 2017-2018. Data on contraception from screening records was paired with the HPV test results, cytological and histological follow-up tests and subsequent HPV test. RESULTS: There was no difference in the risk of being HPV positive, or histological HSIL+, between users of copper-containing IUDs and women with no reported use of contraception. Use of levonorgestrel intrauterine system and hormonal contraception were associated with higher odds for HPV infection in age-adjusted models (aOR 1.21; 95% CI 1.04-1.41, and aOR 1.41; 95% CI 1.22-1.63, respectively) and for HSIL+ (aOR 1.45; 95% CI 1.02-2.06, and aOR 1.56; 95% CI 1.13-2.16, respectively). No significant differences were found in HPV clearance rates. CONCLUSIONS: Reported use of levonorgestrel intrauterine system and hormonal contraception, but not use of copper IUD, was associated with a higher prevalence of HPV infections and histological HSIL + compared to no reported use of contraception.


Women using copper IUD showed no difference in prevalence of HPV or cervical dysplasia compared to women not using contraception in cross-sectional study.


Assuntos
Dispositivos Intrauterinos , Infecções por Papillomavirus , Displasia do Colo do Útero , Humanos , Feminino , Estudos Transversais , Adulto , Infecções por Papillomavirus/epidemiologia , Pessoa de Meia-Idade , Prevalência , Displasia do Colo do Útero/epidemiologia , Suécia/epidemiologia , Dispositivos Intrauterinos/efeitos adversos , Dispositivos Intrauterinos/estatística & dados numéricos , Levanogestrel , Dispositivos Intrauterinos de Cobre/efeitos adversos , Dispositivos Intrauterinos de Cobre/estatística & dados numéricos , Neoplasias do Colo do Útero/epidemiologia , Anticoncepção/estatística & dados numéricos , Anticoncepção/métodos , Dispositivos Intrauterinos Medicados/efeitos adversos
2.
BMC Womens Health ; 24(1): 167, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38459552

RESUMO

BACKGROUND: Robust information on relative effects of hormonal contraceptives on endogenous androgens is important for understanding beneficial and adverse effects, method choice and development of new methods. METHODS: In this ancillary study at the East London, South Africa site of the ECHO multicentre randomized trial, we compared effects of three contraceptive methods on serum androgen levels among contraceptive users aged 18 to 35 years. Participants were allocated by centrally-managed randomization to open label depot medroxyprogesterone acetate (DMPA-IM), copper intrauterine device (IUD) or levonorgestrel implant. The primary outcome was free testosterone at 6 months. RESULTS: We analysed stored baseline and 6-month serum samples in 398/615 participants (DMPA-IM 131/205, IUD 135/205 and implant 132/205). Median testosterone levels at baseline were DMPA-IM 0.82, IUD 0.9 and implant 0.87 nmol/L; at 6 months, DMPA 0.68 (lower than IUD, mean percentage difference 28.35, (p <  0.001), IUD 0.86 (unchanged) and implant 0.66, lower than IUD, mean percentage difference - 22.98, p <  0.001). Median SHBG levels at baseline were DMPA 52.4, IUD 50.5 and implant 55.75 nmol/L; at 6 months, DMPA 40.65, lower than IUD (mean percentage difference 21.19, p = 0.005), IUD 49.1 (unchanged), and implant 23.35 nmol/L, lower than IUD (mean percentage difference - 50.04, p <  0.001 and than DMPA (mean percentage difference - 39.45, p <  0.001). Free testosterone levels at baseline were DMPA 10, IUD 12 and implant 11 pmol/L; at 6 months, DMPA 11, less than IUD (mean percentage difference 13.53, p = 0.047), IUD 12 and implant 14, higher than IUD (mean percentage difference 14.15, p = 0.038) and than DMPA, (mean percentage difference 29.60, p < 0.001). CONCLUSIONS: This is the first randomized trial to show lower SHBG and higher free testosterone with the levonorgestrel implant than with DMPA, and contrasts with reports of increased SHBG with combined oral ethinyl estradiol/levonorgestrel use, and reduced androgens (and impaired sexual function) reported with the etonorgestrel implant. The higher free testosterone with the LNG implant might improve sexual function, mood and bone health as well as increasing side-effects such as acne and hirsutism, and is consistent with the greater sexual activity (with respect to multiple sex partners, new sex partner and unprotected sex) with the implant compared with DMPA documented in the ECHO study. ECHO TRIAL REGISTRATION: ClinicalTrials.gov , number NCT02550067 15/09/2015. Contraception, or family planning, is central to the role of women in societies. It is most important to have accurate information on the relative side-effects of various contraceptive options in order to empower women to make informed choices regarding their preferred method. Hormonal contraceptives contain various forms of the female sex hormones, estrogens and/or progestogens. These hormones have direct effects on the users, as well as modifying the levels of the users' own circulating sex hormones, both the 'female' and the 'male' sex hormones (androgens). In this study, consenting participants requesting contraception, were allocated randomly to receive either depot medroxyprogesterone acetate (DMPA-IM) a 3-monthly progestogen injection, the copper intrauterine device (IUD), a non-hormonal contraceptive inserted within the womb, or the levonorgestrel implant, a device placed under the skin which releases a progestogen for 5 years. We measured the participants' androgen levels after 6 months, and found for the first time that the active form of testosterone (free testosterone) was 29% higher with the implant than with DMPA-IM. The level with the IUD was intermediate, and significantly different from the other two methods. This finding is relevant to the effects experienced by users of these methods, because free testosterone has effects on sexual function, bone health and mood, as well as on conditions such as acne and hair distribution patterns.


Assuntos
Acne Vulgar , Anticoncepcionais Femininos , Dispositivos Intrauterinos de Cobre , Feminino , Humanos , Acne Vulgar/induzido quimicamente , Androgênios , Anticoncepcionais Femininos/efeitos adversos , Dispositivos Intrauterinos de Cobre/efeitos adversos , Levanogestrel/efeitos adversos , Acetato de Medroxiprogesterona/efeitos adversos , Progestinas , Globulina de Ligação a Hormônio Sexual , Testosterona , Adolescente , Adulto Jovem , Adulto
3.
Acta Obstet Gynecol Scand ; 103(2): 342-350, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37983839

RESUMO

INTRODUCTION: Women undergoing an induced abortion are highly fertile and at risk of subsequent unplanned pregnancy. We recently completed a randomized clinical trial showing that routine provision of intrauterine device (IUD) at the time of abortion significantly reduced the risk of subsequent abortion during a 5-year follow up. As the use of highly effective contraception may affect all subsequent pregnancies, we analyzed the rate and distribution of all subsequent pregnancies (deliveries, miscarriages, and abortions), and the risk factors for these various pregnancy outcomes in the above-mentioned randomized clinical trial. MATERIAL AND METHODS: We enrolled adult women requesting first-trimester induced abortion and candidates for IUD for post-abortion contraception. Women (n = 751) were randomized to receive an IUD (either levonorgestrel-releasing IUD or copper IUD) by the clinic responsible for abortion care vs. routine care of IUD provision in primary health care with oral contraceptives for interval contraception. In the present secondary analysis, we identified all deliveries, miscarriages, and abortions in the intervention (n = 375) and control (n = 373) cohorts during the 5-year follow up using the Finnish national registries. The trial is registered at Clinical Trials (NTC01223521). RESULTS: The overall delivery, miscarriage, and abortion rates were 42.0, 12.0 and 32.1/1000 years of follow up (yFU). Any new pregnancy occurred in 98 women in the intervention and in 129 women in the control cohort (hazard ratio 0.73, 95% confidence interval 0.56-0.95, p = 0.023). The effect of routine IUD provision in reducing pregnancies was limited to the first 2 yFU. The number of subsequent induced abortions and of women undergoing it were significantly reduced, and time to abortion was prolonged by the intervention. However, the overall number, the number of women with subsequent delivery or miscarriage, and the times to these events were not significantly affected. History of previous pregnancy (delivery or abortion) and smoking were risk factors for subsequent induced abortion, but not for delivery or miscarriage. CONCLUSIONS: Routine provision of IUD as part of abortion care did not reduce the rates of delivery or miscarriage during the 5-year follow up. The rates of all pregnancies and the need of subsequent induced abortion were reduced by IUD provision during the first 2 yFU.


Assuntos
Aborto Induzido , Aborto Espontâneo , Dispositivos Intrauterinos de Cobre , Dispositivos Intrauterinos , Gravidez , Adulto , Feminino , Humanos , Aborto Espontâneo/etiologia , Resultado da Gravidez , Primeiro Trimestre da Gravidez , Seguimentos
4.
J Manag Care Spec Pharm ; 29(12): 1303-1311, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38058139

RESUMO

BACKGROUND: Intrauterine devices (IUDs) have comparable efficacy to permanent surgical contraceptive methods; however, long-term costs are infrequently considered. Existing estimates inconsistently account for costs outside of IUD insertion or removal, actual duration of use, or differences between hormonal and nonhormonal IUDs. OBJECTIVE: To describe health care resource utilization and commercial payer costs that arise throughout hormonal and nonhormonal IUD use. METHODS: In this retrospective cohort study, paid claims data (Merative, MarketScan) from a large US commercial claims database were evaluated between 2013 and 2019. Claims were included from individuals aged 12 to 45 years who had an IUD inserted in 2014, continuous insurance coverage for 1 year prior to insertion and throughout follow-up, and no insertion, removal, or reinsertion in the previous year. Procedures and services that could be IUD-related were identified using Current Procedural Terminology and International Classification of Diseases, Ninth and Tenth Edition codes. Duration of IUD use was evaluated by Kaplan-Meier analysis of time to IUD removal. Event rates were determined for identified procedures and services; costs were calculated as the sum of payer reimbursements per enrolled individual. All IUD types available during the study period were described: 2 hormonal IUDs (52-mg and 13.5-mg levonorgestrel-releasing [LNG]) and the nonhormonal (380-mm2 copper) IUD. RESULTS: Of 195,009 individuals meeting the age requirement and receiving an IUD in 2014, 63,386 met the inclusion criteria and 53,744 had their IUD type on record-42,777 (67.5%) 52-mg LNG, 2,932 (4.6%) 13.5-mg LNG, and 8,035 (12.7%) nonhormonal IUD users. Despite differences in their indicated duration (13.5-mg LNG, 3 years; 52-mg LNG, 5 years; and nonhormonal, 10 years), most individuals had their IUD removed before its indicated full duration of use (13.5-mg LNG, 56.1%; 52-mg LNG, 61.3%; nonhormonal [at 5 years], 54.6%). The event rate per 100 individuals during the follow-up period was highest for abnormal uterine bleeding (16.2), ovarian cysts (9.3), and surgical management of uterine perforations (4.5). IUD insertion costs (mean ± SE) per enrolled individual for the 13.5-mg LNG, 52-mg LNG, and nonhormonal IUDs were $931 ± $9, $1,107 ± $4, and $897 ± $6, respectively. Cumulative mean ± SE 5-year postinsertion costs for the 13.5-mg LNG, 52-mg LNG, and nonhormonal IUDs were $2,892 ± $232, $1,514 ± $31, and $1,389 ± $97, respectively, among the remaining enrolled individuals. CONCLUSIONS: In this descriptive study of commercially insured IUD users, at least half had their IUD removed before its indicated duration. IUD improvements that reduce the frequency of abnormal uterine bleeding, ovarian cysts, and uterine perforations may help reduce long-term IUD costs.


Assuntos
Anticoncepcionais Femininos , Seguro , Dispositivos Intrauterinos de Cobre , Dispositivos Intrauterinos Medicados , Cistos Ovarianos , Perfuração Uterina , Feminino , Humanos , Estudos Retrospectivos , Hemorragia Uterina
5.
Contraception ; 125: 110089, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37331461

RESUMO

OBJECTIVES: To estimate the hazard of incident idiopathic intracranial hypertension, a potentially blinding condition, among women using levonorgestrel intrauterine devices (LNG-IUD) compared to copper IUD, as conflicting associations have been reported. STUDY DESIGN: This retrospective, longitudinal cohort study identified women ages 18-45 years in a large care network (January 1, 2001, to December 31, 2015) using LNG-IUD, subcutaneous etonogestrel implant, copper IUD, tubal device/surgery, or hysterectomy. Incident idiopathic intracranial hypertension was defined as the first diagnosis code for after 1 year without any codes and following brain imaging or lumbar puncture. Kaplan-Meier analysis estimated time-dependent probabilities of idiopathic intracranial hypertension at 1 and 5 years after incident contraception use, stratified by type. Cox regression estimated the hazard of idiopathic intracranial hypertension associated with LNG-IUD use compared to copper IUD (primary comparison) after adjusting for sociodemographics and factors associated with idiopathic intracranial hypertension (e.g., obesity) or contraception selection. A sensitivity analysis with propensity score-adjusted models was performed. RESULTS: Of 268,280 women, 78,175 (29%) used LNG-IUD, 8715 (3%) etonogestrel implant, 20,275 (8%) copper IUD, 108,216 (40%) hysterectomy, 52,899 (20%) tubal device/surgery, and 208 (0.08%) developed idiopathic intracranial hypertension over a mean follow-up of 2.4 ± 2.4 years. Also, 1-/5-year Kaplan-Meier idiopathic intracranial hypertension probabilities were 0.0004/0.0021 for LNG-IUD and 0.0005/0.0006 for copper IUD users. LNG-IUD use did not show significantly different hazard of idiopathic intracranial hypertension compared to copper IUD (adjusted hazard ratio 1.84 [95% CI 0.88, 3.85]). Sensitivity analyses were similar. CONCLUSIONS: We did not observe a significantly increased hazard of idiopathic intracranial hypertension among women using LNG-IUD compared to copper IUDs. IMPLICATIONS: The lack of an association between LNG-IUD use and idiopathic intracranial hypertension in this large observational study provides reassurance to women considering initiation or continued use of this highly effective contraceptive method.


Assuntos
Anticoncepcionais Femininos , Dispositivos Intrauterinos de Cobre , Dispositivos Intrauterinos Medicados , Pseudotumor Cerebral , Feminino , Humanos , Levanogestrel , Anticoncepcionais Femininos/efeitos adversos , Estudos Retrospectivos , Estudos Longitudinais , Dispositivos Intrauterinos Medicados/efeitos adversos
6.
BMC Pregnancy Childbirth ; 23(1): 474, 2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-37365489

RESUMO

BACKGROUND: Inserting IUDs during cesarean section reduces the need for more manipulation and discomfort. The current conventional manual technique for IUD insertion during cesarean section is not standardized with many modifications and high rates of expulsion, displacement, missed threads, and discontinuation. This study aims to find a standard technique for IUD insertion during cesarean section with the least possible problems, especially displacement and missed threads. METHODS: A randomized controlled study was conducted at Kasr Al-Ainy Maternity Hospital, Cairo University, Egypt. The study was performed over 12 months, from September 2020 to September 2021. Two groups of patients were selected; each group included 420 patients with a desire for IUD insertion during cesarean section. Group (A) (Control group) was subjected to a post-placental intrauterine device (Copper T380) during cesarean section using a conventional manual method; Group (B) (Study group): the IUD (Copper T380) was placed at the top of the uterine fundus using a new technique (intra-cesarean post placental introducer withdrawal IUD insertion technique). RESULTS: There was a significant statistical difference between the two groups regarding displacement of the IUDs at the end of puerperium, at 6 months, non-visibility of IUD threads, and continuation of use with p-value < 0.05. There was no significant statistical difference in the term of duration of surgery. CONCLUSION: The new technique of post-placental IUD insertion can be the standard technique of intra-cesarean section IUD insertion as it is associated with more favorable outcomes among the included women in the form of lower incidence of IUD displacement, non-visibility of IUD threads, and higher rates of continuation without increasing the duration of surgery as compared with the conventional manual technique. TRIAL REGISTRATION: ClinicalTrial.gov ID: NCT05788354, registration date: 28/03/2023 (retrospectively registered).


Assuntos
Dispositivos Intrauterinos de Cobre , Dispositivos Intrauterinos , Feminino , Gravidez , Humanos , Cesárea/métodos , Cobre , Placenta , Período Pós-Parto , Expulsão de Dispositivo Intrauterino
7.
Am J Obstet Gynecol ; 229(2): 93-100, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37001577

RESUMO

The intrauterine device is one of the most effective forms of contraception. Use of the intrauterine device has increased in the United States over the last 2 decades. Two formulations are commercially available in the United States: the levonorgestrel-releasing intrauterine device and the copper intrauterine device. The levonorgestrel intrauterine device releases progestin, causing endometrial suppression and cervical mucus thickening, whereas the primary mechanism of action of the copper intrauterine device is to create a local inflammatory response to prevent fertilization. Whereas the protective effects of combined hormonal contraception against ovarian and endometrial cancer, and of tubal sterilization against ovarian cancer are generally accepted, less is known about the effects of modern intrauterine devices on the development of gynecologic malignancies. The best evidence for a protective effect of intrauterine device use against cancer incidence pertains to levonorgestrel intrauterine devices and endometrial cancer, although studies suggest that both copper intrauterine devices and levonorgestrel intrauterine devices reduce endometrial cancer risk. This is supported by the proposed dual mechanisms of action including both endometrial suppression and a local inflammatory response. Studies on the relationship between intrauterine device use and ovarian cancer risk show conflicting results, although most data suggest reduced risk of ovarian cancer in intrauterine device users. The proposed biological mechanisms of ovarian cancer reduction (foreign-body inflammatory response, increased pH, antiestrogenic effect, ovulation suppression) vary by type of intrauterine device. Whereas it has been well established that use of copper intrauterine devices confers a lower risk of cervical intraepithelial neoplasms, the effect of levonorgestrel intrauterine device use on cervical cancer remains unclear. Older studies have linked its use to a higher incidence of cervical dysplasia, but more recent literature has found a decrease in cervical cancer with intrauterine device use. Various mechanisms of protection are postulated, including device-related inflammatory response in the endocervical canal and prostaglandin-mediated immunosurveillance. Overall, the available evidence suggests that both levonorgestrel intrauterine devices and copper intrauterine devices reduce gynecologic cancer risk. Whereas there is support for the reduction of endometrial cancer risk with hormonal and copper intrauterine device use, and reduction of cervical cancer risk with copper intrauterine device use, evidence in support of risk reduction with levonorgestrel intrauterine device use for cervical and ovarian cancers is less consistent.


Assuntos
Anticoncepcionais Femininos , Neoplasias do Endométrio , Dispositivos Intrauterinos de Cobre , Dispositivos Intrauterinos Medicados , Neoplasias Ovarianas , Neoplasias do Colo do Útero , Feminino , Humanos , Colo do Útero , Anticoncepcionais Femininos/uso terapêutico , Neoplasias do Endométrio/epidemiologia , Dispositivos Intrauterinos de Cobre/efeitos adversos , Dispositivos Intrauterinos Medicados/efeitos adversos , Levanogestrel/uso terapêutico , Levanogestrel/farmacologia , Neoplasias Ovarianas/epidemiologia , Neoplasias do Colo do Útero/epidemiologia , Neoplasias do Colo do Útero/prevenção & controle
8.
Cochrane Database Syst Rev ; 2: CD013744, 2023 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-36847591

RESUMO

BACKGROUND: The copper intrauterine device (Cu-IUD) is a highly effective method of contraception that can also be used for emergency contraception (EC). It is the most effective form of EC, and is more effective than other existing oral regimens also used for EC. The Cu-IUD provides the unique benefit of providing ongoing contraception after it is inserted for EC; however, uptake of this intervention has been limited. Progestin IUDs are a popular method of long-acting, reversible contraception. If these devices were also found to be effective for EC, they would provide a critical additional option for women. These IUDs could not only provide EC and ongoing contraception, but additional non-contraceptive benefits, including a reduction in menstrual bleeding, cancer prevention, and pain management. OBJECTIVES: To examine the safety and effectiveness of progestin-containing IUDs for emergency contraception, compared with copper-containing IUDs, or compared with dedicated oral hormonal methods. SEARCH METHODS: We considered all randomized controlled trials and non-randomized studies of interventions that compared outcomes for individuals seeking a levonorgestrel IUD (LNG-IUD) for EC to a Cu-IUD or dedicated oral EC method. We considered full-text studies, conference abstracts, and unpublished data. We considered studies irrespective of their publication status and language of publication. SELECTION CRITERIA: We included studies comparing progestin IUDs with copper-containing IUDs, or oral EC methods for emergency contraception. DATA COLLECTION AND ANALYSIS: We systematically searched nine medical databases, two trials registries, and one gray literature site. We downloaded all titles and abstracts retrieved by electronic searching to a reference management database, and removed duplicates. Three review authors independently screened titles, abstracts, and full-text reports to determine studies eligible for inclusion. We followed standard Cochrane methodology to assess risk of bias, and analyze and interpret the data. We used GRADE methodology to assess the certainty of the evidence. MAIN RESULTS: We included only one relevant study (711 women); a randomized, controlled, non-inferiority trial comparing LNG-IUDs to Cu-IUDs for EC, with a one-month follow-up. With one study, the evidence was very uncertain for the difference in pregnancy rates, failed insertion rates, expulsion rates, removal rates and the difference in the acceptability of the IUDs. There was also uncertain evidence suggesting the Cu-IUD may slightly increase rates of cramping and the LNG-IUD may slightly increase bleeding and spotting days.  AUTHORS' CONCLUSIONS: This review is limited in its ability to provide definitive evidence regarding the LNG-IUD's equivalence, superiority, or inferiority to the Cu-IUD for EC. Only one study was identified in the review, which had possible risks of bias related to randomization and rare outcomes. Additional studies are needed to provide definitive evidence related to the effectiveness of the LNG-IUD for EC.


Assuntos
Anticoncepção Pós-Coito , Dispositivos Intrauterinos de Cobre , Dispositivos Intrauterinos , Feminino , Humanos , Gravidez , Cobre , Dispositivos Intrauterinos de Cobre/efeitos adversos , Progestinas , Ensaios Clínicos Controlados Aleatórios como Assunto , Esteroides
9.
AIDS Behav ; 27(3): 978-983, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36357806

RESUMO

The Evidence for Contraceptive Options and HIV Outcomes (ECHO) trial found no substantial difference in HIV acquisition risk between women randomised to injectable intramuscular depot medroxyprogesterone acetate (DMPA-IM), copper intrauterine device (Cu-IUD) or the levonorgestrel (LNG) implant. We evaluated post-randomization sexual behavior using an objective marker of condomless vaginal sex in a subset of participants. We conducted a sub-study among 458 ECHO participants at three sites (Cape Town, Johannesburg, Kisumu) to evaluate the frequency of condomless vaginal sex, measured by prostate specific antigen (PSA) detection in vaginal swabs, collected at the month 6 and final visit and the concordance of self-reported condomless vaginal sex with PSA detection, by randomized arm. We compared PSA detection frequency and concordance of PSA and self-reported condomless vaginal sex, by randomized group using Cochran-Mantel-Haenszel tests and adjusted generalized logistic growth curve models. PSA was detected less frequently in the DMPA-IM (16%), compared to the Cu-IUD (21%) and LNG implant (24%) groups, although results were not statistically significant in the unadjusted model when accounting for pre-specified multiple-testing criteria. There were significant differences in PSA detection between the DMPA-IM and LNG-implant groups (odds ratio 0.61 (95% CI 0.40, 0.94) in the adjusted model. There was moderate discordance between self-reported condomless vaginal sex and detection of PSA that was similar across randomized groups. These data suggest that women randomized to Cu-IUD and LNG implant may have had condomless sex more frequently than women randomized to DMPA-IM. The discordance between detectable PSA and self-reported sexual behaviour has important implications for design of future HIV prevention studies.


Assuntos
Anticoncepcionais Femininos , Infecções por HIV , Dispositivos Intrauterinos de Cobre , Masculino , Feminino , Humanos , Levanogestrel , Acetato de Medroxiprogesterona , Sexo sem Proteção , Antígeno Prostático Específico , Distribuição Aleatória , Infecções por HIV/diagnóstico , África do Sul
10.
Rev. bras. ginecol. obstet ; 45(9): 524-534, 2023. tab
Artigo em Inglês | LILACS | ID: biblio-1521773

RESUMO

Abstract Objective To assess the knowledge, attitude, and practice of Brazilian physicians about immediate postpartum and postabortion intrauterine device insertion. Methods Cross-sectional online survey involving physicians on duty in public Brazilian hospitals. Participants answered an anonymous questionnaire with close-ended questions to assess their knowledge, attitude, and experience on the immediate postpartum and postabortion insertion of copper intrauterine devices. Results One hundred twenty-seven physicians working in 23 hospitals in the 5 geographic regions of Brazil completed the questionnaire. Most were female (68.5%) and worked in teaching hospitals (95.3%). The mean (standard deviation) knowledge score (0-10 scale) was 5.3 (1.3); only 27.6% of the participants had overall scores ≥7.0. Most physicians (73.2%) would insert a postpartum intrauterine device in themselves/family members. About 42% of respondents stated that they had not received any training on postpartum or postabortion intrauterine device insertion. In the past 12 months, 19.7%, 22.8%, and 53.5% of respondents stated they had not inserted any intrauterine device during a cesarean section, immediately after a vaginal delivery, or after an abortion, respectively. Conclusion Most study participants have a positive attitude toward the insertion of intrauterine devices in the immediate postpartum period, but they have limited knowledge about the use of this contraceptive method. A large percentage of respondents did not have previous training on postpartum and postabortion intrauterine device insertion and had not performed any such insertions in the last 12 months. Strategies are needed to improve the knowledge, training, and experience of Brazilian physicians on immediate postpartum and postabortion intrauterine device insertion.


Resumo Objetivo Avaliar o conhecimento, atitude e prática de médicos brasileiros sobre a inserção de dispositivos intrauterinos no pós-parto e pós-aborto imediatos. Métodos Estudo transversal com inquérito online envolvendo médicos plantonistas de hospitais públicos brasileiros. Os participantes responderam a um questionário anônimo com perguntas fechadas para avaliar seu conhecimento, atitude e experiência sobre a inserção de dispositivos intrauterinos de cobre no pós-parto e pós-aborto imediatos. Resultados Cento e vinte sete médicos de 23 hospitais localizados nas 5 regiões do Brasil preencheram o questionário. A maioria era do sexo feminino (68,5%) e trabalhava em hospitais de ensino (95,3%). O escore médio (desvio padrão) de conhecimento (escala 0-10) foi 5,3 (1,3); apenas 27,6% tiveram escore ≥7,0. A maioria (73,2%) faria inserção de dispositivo intrauterino no pós-parto imediato em si mesma/familiares. Cerca de 42% dos participantes declararam não ter recebido nenhum treinamento sobre inserção de dispositivos intrauterinos no pós-parto ou pós-aborto imediatos. Nos últimos 12 meses, 19,7%, 22,8% e 53,5% declararam não ter inserido nenhum dispositivo intrauterino durante uma cesárea, após um parto vaginal ou um aborto, respectivamente. Conclusão A maioria dos participantes tem uma atitude positiva em relação à inserção de dispositivos intrauterinos no pós-parto imediato, porém tem um conhecimento limitado sobre esse método. Uma grande porcentagem dos respondentes não teve treinamento sobre inserção de dispositivos intrauterinos no pós-parto ou pós-aborto imediatos e não fez nenhuma inserção desse tipo nos últimos 12 meses. São necessárias estratégias para melhorar o conhecimento, o treinamento e a experiência dos médicos brasileiros sobre a inserção de dispositivos intrauterinos no pós-parto e pós-aborto imediatos.


Assuntos
Humanos , Conhecimentos, Atitudes e Prática em Saúde , Período Pós-Parto , Aborto , Dispositivos Intrauterinos de Cobre
11.
Rev Med Liege ; 77(9): 521-526, 2022 Sep.
Artigo em Francês | MEDLINE | ID: mdl-36082599

RESUMO

Intrauterine devices (IUD) are the oldest of the modern contraceptives. There are currently two types of IUDs: copper IUD (Cu-IUD) and levonorgestrel IUD (LNG-IUD). Both offer high contraceptive effectiveness. Although they have been used for decades, the literature still brings its share of new information on IUDs: impact on oncological risk, non-contraceptive benefits, rare adverse effects, and impact on women's well-being. In addition, Cu-DIU is recognized as the most effective emergency contraceptive and can be inserted up to 5-7 days after the at-risk sexual intercourse. Research is now looking at the effectiveness of LNG-IUD in emergency contraception. Finally, new IUD concepts are also being evaluated: they should allow a reduction in the rate of expulsion, intermenstrual and heavy menstrual bleeding, an increase in comfort and in IUDs duration of use. This article makes an update on the latest developments in terms of intrauterine contraceptives.


Le dispositif intra-utérin (DIU) est le plus ancien des contraceptifs modernes. On distingue les DIU au cuivre (Cu-DIU) et les DIU au lévonorgestrel (LNG-DIU). Ils offrent une haute efficacité contraceptive. Bien qu'ils soient utilisés depuis des décennies, la littérature apporte encore aujourd'hui son lot de nouvelles informations sur les DIU: impact sur le risque oncologique, bénéfices non contraceptifs, effets indésirables rares et impact sur le bien-être des femmes. Par ailleurs, le Cu-DIU est reconnu comme étant le contraceptif d'urgence le plus efficace, pouvant être inséré jusqu'à 5-7 jours après le rapport à risque. La recherche se penche maintenant sur l'efficacité du LNG-DIU en contraception d'urgence. Enfin, de nouveaux concepts de DIU sont aussi à l'étude : ils devraient permettre une réduction du taux d'expulsion, une diminution des méno- et métrorragies, une augmentation du confort et une plus longue durée d'utilisation. Cet article fait le point sur les dernières nouveautés en termes de contraceptifs intra-utérins.


Assuntos
Dispositivos Intrauterinos de Cobre , Dispositivos Intrauterinos Medicados , Anticoncepção/efeitos adversos , Feminino , Humanos , Dispositivos Intrauterinos de Cobre/efeitos adversos , Dispositivos Intrauterinos Medicados/efeitos adversos , Levanogestrel/efeitos adversos
12.
Eur Radiol ; 32(11): 7430-7438, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35524784

RESUMO

OBJECTIVES: Levonorgestrel-releasing intrauterine contraceptive devices (LNG-IUDs) are designed to exhibit only local hormonal effects. There is an ongoing debate on whether LNG-IUDs can have side effects similar to systemic hormonal medication. Benign background parenchymal enhancement (BPE) in dynamic contrast-enhanced (DCE) MRI has been established as a sensitive marker of hormonal stimulation of the breast. We investigated the association between LNG-IUD use and BPE in breast MRI to further explore possible systemic effects of LNG-IUDs. METHODS: Our hospital database was searched to identify premenopausal women without personal history of breast cancer, oophorectomy, and hormone replacement or antihormone therapy, who had undergone standardized DCE breast MRI at least twice, once with and without an LNG-IUD in place. To avoid confounding aging-related effects on BPE, half of included women had their first MRI without, the other half with, LNG-IUD in place. Degree of BPE was analyzed according to the ACR categories. Wilcoxon-matched-pairs signed-rank test was used to compare the distribution of ACR categories with vs. without LNG-IUD. RESULTS: Forty-eight women (mean age, 46 years) were included. In 24/48 women (50% [95% CI: 35.9-64.1%]), ACR categories did not change with vs. without LNG-IUDs. In 23/48 women (48% [33.9-62.1%]), the ACR category was higher with vs. without LNG-IUDs; in 1/48 (2% [0-6%]), the ACR category was lower with vs. without LNG-IUDs. The change of ACR category depending on the presence or absence of an LNG-IUD proved highly significant (p < 0.001). CONCLUSION: The use of an LNG-IUD can be associated with increased BPE in breast MRI, providing further evidence that LNG-IUDs do have systemic effects. KEY POINTS: • The use of levonorgestrel-releasing intrauterine contraceptive devices is associated with increased background parenchymal enhancement in breast MRI. • This suggests that hormonal effects of these devices are not only confined to the uterine cavity, but may be systemic. • Potential systemic effects of levonorgestrel-releasing intrauterine contraceptive devices should therefore be considered.


Assuntos
Dispositivos Intrauterinos de Cobre , Dispositivos Intrauterinos Medicados , Feminino , Humanos , Pessoa de Meia-Idade , Levanogestrel/efeitos adversos , Dispositivos Intrauterinos Medicados/efeitos adversos , Dispositivos Intrauterinos de Cobre/efeitos adversos , Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética
13.
Tissue Eng Part C Methods ; 28(4): 168-175, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35357963

RESUMO

The aim is to study the cellular carcinogenicity of a copper-containing intrauterine device (IUD). So we analyzed the chemical elements of copper-containing IUDs. After that, we used Bhas42 cells in initiation and promotion assays to evaluate the leaching solution that extracted from the copper-containing IUDs at serial dilutions. In the cell carcinogenic experiment, the number of cell foci with malignant transformation was calculated. Although we uncovered no significant differences between the leaching solution at different concentrations and the negative control in the initiation assay, the sample at four concentrations showed significant differences relative to the negative control in the promotion assay (chi-squared test, p < 0.01). Therefore, we preliminarily evaluated that copper-containing IUDs are nongenotoxic carcinogen. Impact statement For the first time, we executed two-stage transformation assays with Bhas42 cells to assess the potential carcinogenicity of a copper-containing intrauterine device (IUD). In this study, we demonstrated that the copper-containing IUD manifested nongenotoxic carcinogenicity, making this the first-ever published report regarding this type of IUD's nongenotoxic carcinogenicity and revealing that its use carries a cancer risk.


Assuntos
Dispositivos Intrauterinos de Cobre , Dispositivos Intrauterinos , Testes de Carcinogenicidade , Cobre/toxicidade , Feminino , Humanos , Técnicas In Vitro
14.
Eur J Contracept Reprod Health Care ; 27(1): 9-15, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34282703

RESUMO

OBJECTIVES: To investigate women's knowledge and attitudes regarding the use of the intrauterine device (IUD) for contraceptive purposes and to explore eventual misconceptions about its benefits, and disadvantages. METHODS: A cross-sectional study was conducted in the Obstetrics and Gynaecology (OB/GYN) outpatient department at King Khalid National Guard Hospital in King Abdul-Aziz Medical City, Jeddah, Saudi Arabia. It involved women aged 15-55 years, who attended the outpatient OB/GYN clinic from July 2018 till May 2019. A validated self-structured questionnaire was used to collect demographic data and clinical data; including, medical and surgical history, obstetrical and gynaecological history. RESULTS: Of 269 participants, 32.3% reported a positive history of unintended pregnancy, and 28.6% declared using or having used IUD, with copper being the most frequent type (17.8%). A majority (81.4%) of the respondents viewed IUD as a contraceptive method only. In comparison, more than 70% declared not knowing the type of IUD used for bleeding control, cycle regulation, endometriosis treatment, cervix cancer prevention, and endometrial hyperplasia. Further, 21.9% and 55.4% believed that IUD increases the risk of ectopic pregnancy and infections, respectively. CONCLUSION: Women attending outpatient clinics in our centre had poor knowledge levels about IUDs, with several misconceptions and apprehensions, especially regarding the risk of genital infections and ectopic pregnancy, which may constitute a significant psychological barrier use.


Assuntos
Dispositivos Intrauterinos de Cobre , Dispositivos Intrauterinos Medicados , Dispositivos Intrauterinos , Atitude , Estudos Transversais , Feminino , Hospitais , Humanos , Levanogestrel , Gravidez , Arábia Saudita
15.
Mol Hum Reprod ; 27(9)2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34427668

RESUMO

Intrauterine devices containing copper placement will release a large amount of Cu2+ into the uterine fluid, leading to local endometrial damage and inflammation, which is considered to be one of the causes of abnormal uterine bleeding. Studies have shown that the metabolism and function of metal ions are related to the regulation of microRNA. The aims of this study were to investigate changes in endometrial microRNA levels after implantation of an intrauterine device containing copper and to preliminarily explore the signalling pathways involved in abnormal uterine bleeding. The subjects were fertile women, aged 25-35, without major obstetrics and gynaecology diseases. Human endometrial tissues were collected before implantation or removal of the intrauterine device containing copper. High-throughput microRNA sequencing was performed on human endometrial tissues, and real-time quantitative PCR, western blotting and immunohistochemistry were used to detect the expression of relevant genes. MicroRNA sequencing results showed that 72 miRNAs were differentially expressed in the endometrial tissue after the insertion of the intrauterine device containing copper. Implantation of an intrauterine device containing copper implantation can up-regulate the expression of miR-144-3p in endometrial tissue, and therefore, decreases the mRNA and protein expression levels of genes related to endometrial injury and tissue repair, including the MT/NF-κB/MMP damage pathway and the THBS-1/TGF-ß/SMAD3 repair pathway. In this study, the molecular mechanisms of abnormal uterine bleeding due to an intrauterine device containing copper were preliminarily investigated. The information will be beneficial for the clinical treatment of abnormal uterine bleeding caused by intrauterine device.


Assuntos
Cobre/farmacologia , Endométrio/efeitos dos fármacos , Dispositivos Intrauterinos de Cobre , MicroRNAs/genética , Adulto , Estudos de Casos e Controles , Endométrio/metabolismo , Endométrio/patologia , Feminino , Regulação da Expressão Gênica/efeitos dos fármacos , Células HEK293 , Humanos , MicroRNAs/efeitos dos fármacos , Implantação de Prótese
16.
J Prim Health Care ; 13(1): 55-62, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33785111

RESUMO

INTRODUCTION There are few studies of user perceptions of the Levonorgestrel Intrauterine System (LNG-IUS; Mirena™), which now has the potential to play an important role in the treatment of women with hyperplasia or early stage endometrial cancer. There is limited evidence on how well the Mirena™ is perceived and accepted by women in this context. AIM To gain an understanding of New Zealand women's views on the use of the Mirena™ contraceptive device to inform policies in endometrial cancer prevention. METHODS An online survey platform (Qualtrics™) was disseminated over social media sites such as Facebook once a week for 3 weeks. The survey used mixed methods (closed questions, multiple choice and open-ended questions) and covered topics relating to the knowledge and use of the Mirena™ for endometrial protection. Data were collected and explored using content and thematic analysis. RESULTS In total, 89 women responded to the survey. Half (42/89) of respondents had never used a Mirena™ in their life. Most women (79/89) did not know anyone who had had endometrial cancer. The frequency of negative comments about the Mirena™ was higher than positive comments (42 and 26 respectively), largely attributed to personal or reported poor experiences with other contraceptives (including the copper intrauterine device). DISCUSSION Although health-care providers may view the Mirena™ favourably, this view was not reciprocated in this community sample.


Assuntos
Dispositivos Intrauterinos de Cobre , Dispositivos Intrauterinos Medicados , Administração Tópica , Feminino , Humanos , Levanogestrel , Inquéritos e Questionários
18.
Eur J Obstet Gynecol Reprod Biol ; 255: 20-24, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33065517

RESUMO

OBJECTIVE: To assess the influence of the copper IUD and LNG-IUS on liquid-based cytology results (cellular atypia, reactive alterations, and microbiology). STUDY DESIGN: This cross-sectional study was performed between January 2012 and December 2017 in the Northeast of Brazil. Three study groups, the LNG-IUS group (n = 1179), copper IUD group (n = 519), and a control group of women not using contraception (n = 14,616) were compared. To facilitate this analysis, the LNG-IUS and IUD groups were further divided into less and more than two years of use. RESULTS: The mean age of the LNG-IUS and IUD groups was around 36 years and the control group was about 35 years (p = ns). The meantime between dispositive placement and examination was 19 ± 16 months for the LNG-IUS and 17 ± 15 months for the IUD. The frequency of epithelial atypia revealed upon cytological analysis did not differ between the groups. However, inflammatory infiltrates were significantly more frequent in the LNG-IUS and IUD (OR IUD = 1.32; OR LNG-IUS = 1.79) groups relative to control. Candida and cytolysis were more frequent in the LNG-IUS group (OR = 4.73 and 2.41, respectively) compared to both other groups. Bacterial vaginosis andActinomyces sp occurred more frequently in the IUD group (OR = 1.39 and 3352.55, respectively) compared to both other groups. Bacterial vaginosis was more common when using an IUD for more than two years than for less than two years (OR = 2.55). The Actinomyces morphotype was also observed at greater frequency after two years of IUD use than before (OR = 5.35). CONCLUSIONS: The LNG-IUS and copper IUD do not affect the incidence of cellular atypia but do interfere with the microbiota over time. Specifically, the copper IUD is associated with bacterial vaginosis andActinomyces sp infection while the LNG-IUS is associated with candidiasis and cytolysis.


Assuntos
Anticoncepcionais Femininos , Dispositivos Intrauterinos de Cobre , Dispositivos Intrauterinos Medicados , Adulto , Brasil , Estudos Transversais , Feminino , Humanos , Dispositivos Intrauterinos de Cobre/efeitos adversos , Dispositivos Intrauterinos Medicados/efeitos adversos , Levanogestrel
19.
Femina ; 48(9): 574-576, set. 30, 2020.
Artigo em Português | LILACS | ID: biblio-1122590

RESUMO

Os dispositivos intrauterinos (DIUs) são os métodos contraceptivos reversíveis de longa duração mais utilizados no mundo, apresentando altas taxas de eficácia e segurança. Na presença de gestação, o DIU pode ser retirado com uma leve tração dos fios, quando visíveis. Na impossibilidade de visualização dos fios, há a opção de retirada por histeroscopia, que tem se mostrado segura e eficaz para a retirada de DIU retido na cavidade. Foram pesquisados os termos: "intrauterine device", "pregnancy" e "hysteroscopy". Dos 378 artigos encontrados, foram selecionados 18 artigos que cumpriam os objetivos desta revisão. A presença de DIU durante a gestação se mostra um fator de risco independente para desfechos desfavoráveis como abortamento, corioamnionite, parto prematuro e maior taxa de admissão em unidade de terapia intensiva neonatal. A histeroscopia ambulatorial se mostra uma alternativa segura e eficaz na retirada do DIU no primeiro trimestre.(AU)


Intrauterine devices (IUDs) are the most widely used reversible contraceptive methods in the world, with high rates of efficacy and safety. In the presence of pregnancy, the IUD can be removed by gently traction of the threads, when visible. If the wires cannot be visualized, we have the option of hysteroscopy removal, which has been shown to be safe and effective for the removal of an IUD retained in the cavity. The terms "intrauterine device", "pregnancy" and "hysteroscopy" were searched. Of the 378 articles found, 18 articles were selected that met the objectives of this review. The presence of IUDs during pregnancy is an independent risk factor for unfavorable outcomes such as abortion, chorioamnionitis, premature birth and a higher rate of admission to a neonatal intensive care unit. Ambulatory hysteroscopy is a safe and effective alternative for IUD removal in the first trimester.(AU)


Assuntos
Humanos , Feminino , Gravidez , Complicações na Gravidez/prevenção & controle , Histeroscopia , Dispositivos Intrauterinos , Dispositivos Intrauterinos de Cobre , Primeiro Trimestre da Gravidez , Fatores de Risco , Bases de Dados Bibliográficas , Cobre/uso terapêutico , Eficácia de Contraceptivos
20.
Am J Obstet Gynecol ; 223(6): 886.e1-886.e17, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32562657

RESUMO

BACKGROUND: Since 2013, the residents of the city of Vantaa, Finland, have been offered their first long-acting reversible contraceptive method (levonorgestrel-releasing intrauterine system, implant, and copper intrauterine device) free of charge. OBJECTIVE: The primary aim of this study was to assess the 2-year cumulative discontinuation rates of long-acting reversible contraceptive methods when provided free of charge for first-time users in a real-world setting. Additional aims were to describe factors associated with discontinuation and to evaluate the reasons for discontinuation. STUDY DESIGN: This is a retrospective register-based cohort study of 2026 nonsterilized women aged 15 to 44 years, who initiated a free-of-charge long-acting contraceptive method in 2013-2014 in the city of Vantaa. Removals within 2 years after method initiation and reasons for discontinuation were obtained from electronic health records and from national registers. We calculated the 2-year cumulative incidence rates of discontinuation with 95% confidence intervals for each method. Furthermore, we assessed crude and adjusted incidence rate ratios of discontinuation with 95% confidence interval by Poisson regression models comparing implants and copper intrauterine device with levonorgestrel-releasing intrauterine systems. RESULTS: During the 2 -year follow-up, 514 women discontinued, yielding a cumulative discontinuation rate of 28.3 per 100 women-years (95% confidence interval, 26.2-30.4). Among the 1199 women who initiated the levonorgestrel-releasing intrauterine system, the cumulative discontinuation rate was 24.2 per 100 women-years (95% confidence interval, 21.7-26.9); among the 642 implant users, 33.3 per 100 women-years (95% confidence interval, 29.5-37.4); and among the 185 copper intrauterine device users, 37.8 per 100 women-years (95% confidence interval, 31.0-45.7). Compared with women aged 30 to 44 years, women aged 15 to 19 years (adjusted incidence rate ratio, 1.58; 95% confidence interval, 1.17-2.14) and 20 to 29 years (adjusted incidence rate ratio, 1.35; 95% confidence interval, 1.11-1.63) were more likely to discontinue. We observed a higher discontinuation rate in women who had given birth within the previous year (adjusted incidence rate ratio, 1.36; 95% confidence interval, 1.13-1.65), spoke a native language other than Finnish or Swedish (adjusted incidence rate ratio, 1.31; 95% confidence interval, 1.06-1.63), and had a history of a sexually transmitted infection (adjusted incidence rate ratio, 1.62; 95% confidence interval, 1.07-2.46). No association was found in marital status, overall parity, history of induced abortion, socioeconomic status, education level, or smoking status. The most common reason for discontinuation was bleeding disturbances, reported by 21% of women who discontinued the levonorgestrel-releasing intrauterine system, by 71% who discontinued the implant, and by 41% who discontinued the copper intrauterine device. One in 4 women who discontinued the copper intrauterine device reported heavy menstrual bleeding, whereas only 1% who discontinued the levonorgestrel-releasing intrauterine system and none who discontinued implants reported this reason. Abdominal pain was the reported reason for discontinuation in 20% of both intrauterine device users and in only 2% who discontinued implants. CONCLUSION: At 2 years, the use of implants and copper intrauterine devices was more likely to be discontinued than that of the levonorgestrel-releasing intrauterine system. Women younger than 30 years and those who gave birth in the preceding year, spoke a native language other than Finnish or Swedish, or had a history of sexually transmitted infections were more likely to discontinue. The levonorgestrel-releasing intrauterine system was least likely to be removed owing to bleeding disturbances.


Assuntos
Anticoncepcionais Femininos/administração & dosagem , Remoção de Dispositivo/estatística & dados numéricos , Dispositivos Intrauterinos de Cobre/estatística & dados numéricos , Dispositivos Intrauterinos Medicados/estatística & dados numéricos , Aborto Induzido , Adolescente , Adulto , Fatores Etários , Estudos de Coortes , Implantes de Medicamento/economia , Implantes de Medicamento/uso terapêutico , Escolaridade , Feminino , Financiamento Governamental , Finlândia/epidemiologia , Humanos , Dispositivos Intrauterinos de Cobre/economia , Dispositivos Intrauterinos Medicados/economia , Levanogestrel/administração & dosagem , Contracepção Reversível de Longo Prazo/economia , Contracepção Reversível de Longo Prazo/estatística & dados numéricos , Estado Civil , Distúrbios Menstruais/induzido quimicamente , Paridade , Estudos Retrospectivos , Fumar/epidemiologia , Classe Social , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA