Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Cataract Refract Surg ; 34(3): 357-63, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18299057

RESUMO

PURPOSE: To study the incidence of and risk factors for postoperative capsular block syndrome (CBS) and propose a new classification based on etiology. SETTING: Department of Ophthalmology, Kyungpook National University Hospital, Daegu, Republic of Korea. METHODS: Charts of 1100 eyes of 990 patients who had phacoemulsification and posterior chamber intraocular lens (PC IOL) implantation between January 2003 and June 2006 were retrospectively reviewed. Demographic data, axial length (AL), type of PC IOL implanted, and intraoperative ophthalmic viscosurgical devices (OVDs) were recorded. The cases of postoperative CBS were collected and the characteristic clinical findings evaluated. RESULTS: There were 8 cases (7 patients) of postoperative CBS (incidence 0.73%). Longer AL (>or=25.0 mm) was a risk factor for postoperative CBS (P= .008; odds ratio [OR], 5.75, 95% confidence interval [CI], 1.353-24.413). The PC IOL with 4 haptics (Akreos Adapt, Bausch & Lomb) was also associated with an increased incidence of postoperative CBS (P= .001; OR, 7.388; 95% CI, 1.751-31.168). The CBS was classified as noncellular, inflammatory, or fibrotic according to the clinical characteristics. CONCLUSIONS: Although postoperative CBS was a rare complication after cataract surgery, AL and PC IOL design had a significant influence on the incidence. Evaluation of clinical characteristics showed 3 distinct types of CBS.


Assuntos
Cápsula do Cristalino/patologia , Doenças do Cristalino/classificação , Implante de Lente Intraocular , Facoemulsificação , Complicações Pós-Operatórias , Adulto , Idoso , Feminino , Humanos , Incidência , Pressão Intraocular , Doenças do Cristalino/etiologia , Masculino , Pessoa de Meia-Idade , Razão de Chances , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Síndrome , Tonometria Ocular
2.
Graefes Arch Clin Exp Ophthalmol ; 245(11): 1653-8, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17562063

RESUMO

BACKGROUND: Capsule defects are common during or after intraocular surgery of various kinds. The purpose of this work is to establish a classification system of lens capsule defects to provide uniform description of these defects for ophthalmic research and IOL implantation. METHODS: A retrospective study of 128 patients (156 eyes) with lens capsule injury after ocular trauma and intraocular surgery was performed. The patients were divided into two groups. Capsule defects were defined and classified according to the location, size, shape and tension of the capsule and its effect on posterior chamber IOL implantation. RESULTS: Lens capsule defects were classified into four types: Type I - complete capsule; Type II - incomplete capsule, but has enough area and tension to support two IOL haptics; Type III - incomplete capsule, is able to support only one IOL haptic and the other haptic needs a suture; Type IV - no capsule, both IOL haptics need suture fixation. Type I and Type II were each divided into three subtypes. Type III was divided into two subtypes. The shape of the capsule defects included fissure-like, triangle, round, irregular and fan-like. All eyes with capsule defects can be sorted into one of these types, and it is easy to guide IOL implantation according to the classification. Type II was the most common among the two groups in this study. CONCLUSION: The classification of lens capsule defects is feasible and favorable for uniform clinical description, clinical research and IOL implantation.


Assuntos
Cápsula do Cristalino/patologia , Doenças do Cristalino/classificação , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Pressão Intraocular/fisiologia , Implante de Lente Intraocular , Lentes Intraoculares , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA