1.
Radiat Environ Biophys ; 63(2): 203-214, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38683360

RESUMO

The study aimed to evaluate dosimetry systems used for stereotactic body radiotherapy (SBRT), specifically 2D array dosimetry and film dosimetry systems, for exploring their characteristics and clinical suitability. For this, high-resolution myQA SRS detectors and Gafchromic EBT-XD films were employed. Film analysis included net optical density (OD) values depending on energy, dose rate, scanner orientation, scanning side, and post-exposure growth. For myQA SRS, signal values were evaluated in terms of dose rate (400-1400 MU/min) and angular dependence (0-180° at 30° intervals) along with couch angles of 0°, 45°, and 90°. Pre-treatment verification included 32 SBRT patients for whom myQA SRS results were compared with those obtained with Gafchromic EBT-XD films. Analysis revealed less than 1% deviation in net OD for energy and dose rate dependence. Scanner orientation caused 2.5% net OD variation, with minimal differences between film front and back scan orientations (variance < 1.0%). A rapid OD rise occurred within six hours post-exposure, followed by gradual increase. The myQA SRS detector showed - 3.7% dose rate dependence (400 MU/min), while the angular dependence at 90° was - 26.7%. A correction factor effectively reduced these differences to < 1%. For myQA SRS, gamma passing rates were-93.6% (2%/1 mm), while those for EBT-XD films were-92.8%. Improved rates were observed with 3%/1 mm: for myQA SRS-97.9%, and for EBT-XD film-98.16%. In contrast, for 2%/2 mm with 10% threshold, for myQA SRS-97.7% and for EBT-XD film-98.97% were obtained. It is concluded that both myQA SRS detectors and EBT-XD films are suitable for SBRT pre-treatment verification, ensuring accuracy and reliability. However, myQA SRS detectors are preferred over EBT-XD film due to the fact that they offer real-time measurements and user-friendly features.


Assuntos
Dosimetria Fotográfica , Radiocirurgia , Radiocirurgia/métodos , Humanos , Dosagem Radioterapêutica
2.
Phys Med Biol ; 69(7)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38394683

RESUMO

Optically stimulated luminescence (OSL) film dosimeters, based on BaFBr:Eu2+phosphor material, have major dosimetric advantages such as dose linearity, high spatial resolution, film re-usability, and immediate film readout. However, they exhibit an energy-dependent over-response at low photon energies because they are not made of tissue-equivalent materials. In this work, the OSL energy-dependent response was optimized by lowering the phosphor grain size and seeking an optimal choice of phosphor concentration and film thickness to achieve sufficient signal sensitivity. This optimization process combines measurement-based assessments of energy response in narrow x-ray beams with various energy response calculation methods applied to different film metrics. Theoretical approaches and MC dose simulations were used for homogeneous phosphor distributions and for isolated phosphor grains of different dimensions, where the dose in the phosphor grain was calculated. In total 8 OSL films were manufactured with different BaFBr:Eu2+median particle diameters (D50): 3.2µm, 1.5µm and 230 nm and different phosphor concentrations (1.6%, 5.3% and 21.3 %) and thicknesses (from 5.2 to 49µm). Films were irradiated in narrow x-ray spectra (N60, N80, N-150 and N-300) and the signal intensity relative to the nominal dose-to-water value was normalized to Co-60. Finally, we experimentally tested the response of several films in Varian 6MV TrueBeam STx linear accelerator using the following settings: 10 × 10 cm2field, 0deggantry angle, 90 cm SSD, 10 cm depth. The x-ray irradiation experiment reported a reduced energy response for the smallest grain size with an inverse correlation between response and grain size. The N-60 irradiation showed a 43% reduction in the energy over-response when going from 3µm to 230 nm grain size for the 5% phosphor concentration. Energy response calculation using a homogeneous dispersion of the phosphor underestimated the experimental response and was not able to obtain the experimental correlation between grain size and energy response. Isolated grain size modeling combined with MC dose simulations allowed to establish a good agreement with experimental data, and enabled steering the production of optimized OSL-films. The clinical 6 MV beam test confirmed a reduction in energy dependence, which is visible in small-grain films where a decrease in out-of-field over-response was observed.


Assuntos
Dosimetria por Luminescência Estimulada Opticamente , Método de Monte Carlo , Radiometria , Luminescência , Raios X , Dosimetria Fotográfica/métodos
3.
Br J Radiol ; 97(1155): 646-651, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38273671

RESUMO

OBJECTIVES: To establish the variation in film dosimetry usage in radiotherapy centres across the United Kingdom. To identify consensus and highlight areas of potential improvement to enhance radiotherapy dosimetry verification with film. METHODS: A survey questionnaire was designed by members of the Institute of Physics and Engineering in Medicine Interdepartmental Dosimetry Audit Group via Microsoft Forms and distributed to all Heads of Radiotherapy Physics in the United Kingdom. The survey was open from June 19, 2023, to July 31, 2023. RESULTS: Forty responses were received from the 62 radiotherapy centres in the United Kingdom, of which 58% were currently using film dosimetry and a further 7 were keen to commence use. Many reported film use had decreased in recent years but was still valuable particularly for commissioning and implementing new techniques. The variation and consensus of methods for film dosimetry calibration, measurement, and application was established. A review of barriers to implementation and methods to reduce uncertainty were included in the assessment. CONCLUSIONS: A comprehensive assessment of film dosimetry usage in radiotherapy in the United Kingdom has been collated, which demonstrates a wide variation in methods, across typical clinical users, but maintains film as a valuable dosimetry option. ADVANCES IN KNOWLEDGE: This research provides a snapshot of current film dosimetry use across the United Kingdom. It examines the variation and consensus of practice to which individual users can compare their systems, and identifies opportunities to improvement in the accuracy of film dosimetry.


Assuntos
Dosimetria Fotográfica , Radioterapia (Especialidade) , Humanos , Dosagem Radioterapêutica , Dosimetria Fotográfica/métodos , Radiometria , Reino Unido , Calibragem
4.
Med Phys ; 51(5): 3734-3745, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38224326

RESUMO

BACKGROUND: Cherenkov luminescence imaging has shown potential for relative dose distribution and field verification in radiation therapy. However, to date, limited research utilizing Cherenkov luminescence for absolute dose calibration has been conducted owing to uncertainties arising from camera positioning and tissue surface optical properties. PURPOSE: This paper introduces a novel approach to multispectral Cherenkov luminescence imaging combined with Fricke-xylenol orange gel (FXG) film, termed MCIFF, which can enable online full-field absolute dose measurement. By integrating these two approaches, MCIFF allows for calibration of the ratio between two spectral intensities with absorbed dose, thereby enabling absolute dose measurement. METHODS: All experiments are conducted on a Varian Clinac 23EX, utilizing an electron multiplying charge-coupled device (EMCCD) camera and a two-way image splitter for simultaneous capture of two-spectral Cherenkov imaging. In the first part of this study, the absorbance curves of the prepared FXG film, which receives different doses, are measured using a fluorescence spectrophotometer to verify the correlation between absorbance and dose. In the second part, the FXG film is positioned directly under the radiation beam to corroborate the dose measurement capacity of MCIFF across various beams. In the third part, the feasibility of MCIFF is tested in actual radiotherapy settings via a humanoid model, demonstrating its versatility with various radiotherapy materials. RESULTS: The results of this study indicate that the logarithmic ratios of spectral intensities at wavelengths of 550 ± 50 and 700 ± 100 nm accurately reflect variations in radiation dose (R2 > 0.96) across different radiation beams, particle energies, and dose rates. The slopes of the fitting lines remain consistent under varying beam conditions, with discrepancies of less than 8%. The optical profiles obtained using the MCIFF exhibit a satisfactory level of agreement with the measured results derived from the treatment planning system (TPS) and EBT3 films. Specifically, for photon beams, the lateral distances between the 80% and 20% isodose lines, referred to as the penumbra (P80-20) values, obtained through TPS, EBT3 films, and MCIFF, are determined as 0.537, 0.664, and 0.848 cm, respectively. Similarly, for electron beams, the P80-20 values obtained through TPS, EBT3 films, and MCIFF are found to be 0.432, 0.561, and 0.634 cm, respectively. Furthermore, imaging of the anthropomorphic phantom demonstrates the practical application of MCIFF in real radiotherapy environments. CONCLUSION: By combining an FXG film with Cherenkov luminescence imaging, MCIFF can calibrate Cherenkov luminescence to absorbed dose, filling the gap in online 2D absolute dose measurement methods in clinical practice, and providing a new direction for the clinical application of optical imaging to radiation therapy.


Assuntos
Dosimetria Fotográfica , Dosimetria Fotográfica/instrumentação , Dosimetria Fotográfica/métodos , Calibragem , Géis , Xilenos/química , Doses de Radiação , Sulfóxidos , Fenóis , Imagem Óptica/instrumentação
5.
Phys Med Biol ; 69(5)2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38295408

RESUMO

Objective.Spatially-fractionated radiotherapy (SFRT) delivered with a very-high-energy electron (VHEE) beam and a mini-GRID collimator was investigated to achieve synergistic normal tissue-sparing through spatial fractionation and the FLASH effect.Approach.A tungsten mini-GRID collimator for delivering VHEE SFRT was optimized using Monte Carlo (MC) simulations. Peak-to-valley dose ratios (PVDRs), depths of convergence (DoCs, PVDR ≤ 1.1), and peak and valley doses in a water phantom from a simulated 150 MeV VHEE source were evaluated. Collimator thickness, hole width, and septal width were varied to determine an optimal value for each parameter that maximized PVDR and DoC. The optimized collimator (20 mm thick rectangular prism with a 15 mm × 15 mm face with a 7 × 7 array of 0.5 mm holes separated by 1.1 mm septa) was 3D-printed and used for VHEE irradiations with the CERN linear electron accelerator for research beam. Open beam and mini-GRID irradiations were performed at 140, 175, and 200 MeV and dose was recorded with radiochromic films in a water tank. PVDR, central-axis (CAX) and valley dose rates and DoCs were evaluated.Main results.Films demonstrated peak and valley dose rates on the order of 100 s of MGy/s, which could promote FLASH-sparing effects. Across the three energies, PVDRs of 2-4 at 13 mm depth and DoCs between 39 and 47 mm were achieved. Open beam and mini-GRID MC simulations were run to replicate the film results at 200 MeV. For the mini-GRID irradiations, the film CAX dose was on average 15% higher, the film valley dose was 28% higher, and the film PVDR was 15% lower than calculated by MC.Significance.Ultimately, the PVDRs and DoCs were determined to be too low for a significant potential for SFRT tissue-sparing effects to be present, particularly at depth. Further beam delivery optimization and investigations of new means of spatial fractionation are warranted.


Assuntos
Elétrons , Dosimetria Fotográfica , Método de Monte Carlo , Dosimetria Fotográfica/métodos , Síncrotrons , Carmustina , Água , Dosagem Radioterapêutica , Radiometria
6.
J Appl Clin Med Phys ; 25(1): e14229, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38032123

RESUMO

BACKGROUND: Pulsed reduced dose rate (PRDR) is an emerging radiotherapy technique for recurrent diseases. It is pertinent that the linac beam characteristics are evaluated for PRDR dose rates and a suitable dosimeter is employed for IMRT QA. PURPOSE: This study sought to investigate the pulse characteristics of a 6 MV photon beam during PRDR irradiations on a commercial linac. The feasibility of using EBT3 radiochromic film for use in IMRT QA was also investigated by comparing its response to a commercial diode array phantom. METHODS: A plastic scintillator detector was employed to measure the photon pulse characteristics across nominal repetition rates (NRRs) in the 5-600 MU/min range. Film was irradiated with dose rates in the 0.033-4 Gy/min range to study the dose rate dependence. Five clinical PRDR treatment plans were selected for IMRT QA with the Delta4 phantom and EBT3 film sheets. The planned and measured dose were compared using gamma analysis with a criterion of 3%/3 mm. EBT3 film QA was performed using a cumulative technique and a weighting factor technique. RESULTS: Negligible differences were observed in the pulse width and height data between the investigated NRRs. The pulse width was measured to be 3.15 ± 0.01 µ s $\mu s$ and the PRF was calculated to be 3-357 Hz for the 5-600 MU/min NRRs. The EBT3 film was found to be dose rate independent within 3%. The gamma pass rates (GPRs) were above 99% and 90% for the Delta4 phantom and the EBT3 film using the cumulative QA method, respectively. GPRs as low as 80% were noted for the weighting factor EBT3 QA method. CONCLUSIONS: Altering the NRRs changes the mean dose rate while the instantaneous dose rate remains constant. The EBT3 film was found to be suitable for PRDR dosimetry and IMRT QA with minimal dose rate dependence.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Dosimetria Fotográfica/métodos , Radiometria , Raios gama , Fótons
7.
J Appl Clin Med Phys ; 25(3): e14203, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37937814

RESUMO

AIM: The aim of this study was to investigate the suitability of three radiochromic film analysis software for stereotactic radiotherapy patient-specific quality assurance (PSQA): FilmQA Pro v5.0, SNC Patient v6.2, and eFilmQA v5.0. METHODS: Film calibration was conducted for each software followed by three sets of measurements. The first set assessed calibration accuracy by comparing measured and delivered doses at increments different from those used for calibration. The second set used each software to conduct PSQA through gamma analysis on 10 stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) patients. The third set utilized SNC Patient and eFilmQA to carry out gamma analysis on a collection of four digital test images, eliminating delivery and scanning uncertainties from impacting the analysis. Key supporting features within each software for conducting gamma analysis were identified. RESULTS: Overall, FilmQA Pro and eFilmQA were deemed comparable and favoured over SNC Patient due to the presence of key features such as triple-channel dosimetry, auto-optimization, and dose scaling. FilmQA Pro has a substantial user base and established reputation. eFilmQA, having been introduced more recently, serves as a viable alternative to FilmQA Pro, having been further refined for stereotactic radiotherapy PSQA. CONCLUSION: This study investigated the suitability of three film analysis software (FilmQA Pro, eFilmQA, and SNC Patient) for stereotactic radiotherapy PSQA. Results from the investigation indicated that both FilmQA Pro and eFilmQA are comparably suitable and are preferred over SNC Patient. Both FilmQA Pro and eFilmQA are recommended for radiotherapy clinics.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Radiocirurgia/métodos , Dosimetria Fotográfica/métodos , Software , Dosagem Radioterapêutica , Radiometria , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador
8.
Phys Med ; 114: 103147, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37804712

RESUMO

Radiotherapy is part of the treatment of over 50% of cancer patients. Its efficacy is limited by the radiotoxicity to the healthy tissue. FLASH-RT is based on the biological effect that ultra-high dose rates (UHDR) and very short treatment times strongly reduce normal tissue toxicity, while preserving the anti-tumoral effect. Despite many positive preclinical results, the translation of FLASH-RT to the clinic is hampered by the lack of accurate dosimetry for UHDR beams. To date radiochromic film is commonly used for dose assessment but has the drawback of lengthy and cumbersome read out procedures. In this work, we investigate the equivalence of a 2D OSL system to radiochromic film dosimetry in terms of dose rate independency. The comparison of both systems was done using the ElectronFlash linac. We investigated the dose rate dependence by variation of the (1) modality, (2) pulse repetition frequency, (3) pulse length and (4) source to surface distance. Additionally, we compared the 2D characteristics by field size measurements. The OSL calibration showed transferable between conventional and UHDR modality. Both systems are equally independent of average dose rate, pulse length and instantaneous dose rate. The OSL system showed equivalent in field size determination within 3 sigma. We show the promising nature of the 2D OSL system to serve as alternative for radiochromic film in UHDR electron beams. However, more in depth characterization is needed to assess its full potential.


Assuntos
Elétrons , Dosimetria por Luminescência Estimulada Opticamente , Humanos , Imagens de Fantasmas , Radiometria , Planejamento da Radioterapia Assistida por Computador/métodos , Dosimetria Fotográfica/métodos
9.
PLoS One ; 18(10): e0293191, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37871021

RESUMO

In this study, some confusing points about electron film dosimetry using white polystyrene suggested by international protocols were verified using a clinical linear accelerator (LINAC). According to international protocol recommendations, ionometric measurements and film dosimetry were performed on an SP34 slab phantom at various electron energies. Scaling factor analysis using ionometric measurements yielded a depth scaling factor of 0.923 and a fluence scaling factor of 1.019 at an electron beam energy of <10 MeV (i.e., R50 < 4.0 g/cm2). It was confirmed that the water-equivalent characteristics were similar because they have values similar to white polystyrene (i.e., depth scaling factor of 0.922 and fluence scaling factor of 1.019) presented in international protocols. Furthermore, percentage depth dose (PDD) curve analysis using film dosimetry showed that when the density thickness of the SP34 slab phantom was assumed to be water-equivalent, it was found to be most similar to the PDD curve measured using an ionization chamber in water as a reference medium. Therefore, we proved that the international protocol recommendation that no correction for measured depth dose is required means that no scaling factor correction for the plastic phantom is necessary. This study confirmed two confusing points that could occur while determining beam characteristics using electron film dosimetry, and it is expected to be used as basic data for future research on clinical LINACs.


Assuntos
Dosimetria Fotográfica , Poliestirenos , Dosimetria Fotográfica/métodos , Aceleradores de Partículas , Radioterapia de Alta Energia/métodos , Imagens de Fantasmas , Água , Radiometria/métodos
10.
Phys Med Biol ; 68(19)2023 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-37703904

RESUMO

Objective. The gamma index (γ) has been extensively investigated in the medical physics and applied in clinical practice. However,γhas a significant limitation when used to evaluate the dose-gradient region, leading to inconveniences, particularly in stereotactic radiotherapy (SRT). This study proposes a novel evaluation method combined withγto extract clinically problematic dose-gradient regions caused by irradiation including certain errors.Approach. A flow-vector field in the dose distribution is obtained when the dose is considered a scalar potential. Using the Lie derivative from differential geometry, we definedL,S, andUto evaluate the intensity, vorticity, and flow amount of deviation between two dose distributions, respectively. These metrics multiplied byγ(γL,γS,γU), along with the threshold valueσ, were verified in the ideal SRT case and in a clinical case of irradiation near the brainstem region using radiochromic films. Moreover, Moran's gradient index (MGI), Bakai's χ factor, and the structural similarity index (SSIM) were investigated for comparisons.Main results. A highL-metric value mainly extracted high-dose-gradient induced deviations, which was supported by highSandUmetrics observed as a robust deviation and an influence of the dose-gradient, respectively. TheS-metric also denotes the measured similarity between the compared dose distributions. In theγdistribution,γLsensitively detected the dose-gradient region in the film measurement, despite the presence of noise. The thresholdσsuccessfully extracted the gradient-error region whereγ> 1 analysis underestimated, andσ= 0.1 (plan) andσ= 0.001 (film measurement) were obtained according to the compared resolutions. However, the MGI, χ, and SSIM failed to detect the clinically interested region.Significance. Although further studies are required to clarify the error details, this study demonstrated that the Lie derivative method provided a novel perspective for the identifying gradient-induced error regions and enabled enhanced and clinically significant evaluations ofγ.


Assuntos
Dosimetria Fotográfica , Radiocirurgia , Dosimetria Fotográfica/métodos , Dosagem Radioterapêutica , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
11.
Acta Oncol ; 62(10): 1215-1221, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37672563

RESUMO

PURPOSE: This study aims to evaluate different methods for calibrating EBT-XD films to develop a precise pre-treatment verification method for stereotactic radiotherapy (SRT) patients using the HyperArc (HA, Varian Medical System) technique. METHODS: Gafchromic EBT-XD films were calibrated using three different approaches: manual calibration, EDW calibration, and PDD calibration. Films were digitalized with an Epson V850 Pro scanner applying the local scanning protocol. Three clinical treatment plans were selected for evaluation. Patient-specific QA films were irradiated in the Mobius MVP phantom and the STEEV phantom. Scanned film images were converted into dose images using the calibration curves. Gamma analysis was performed to compare film dose and TPS calculated dose with various criteria. RESULTS: The scan-to-scan variation was evaluated to be ≤ 0.2%. The accuracy of the calibration curves was verified and the deviation from the converted dose deviates ≤ 3% from the known delivered dose. The gamma passing rate for all calibration methods was found to be over 94% with clinically relevant criteria. EDW calibration demonstrated higher average gamma passing rates compared to the manual method for single target plans, which is 99% ± 1.2% and 98.8% ± 1.5%, respectively. PDD method demonstrated improved agreement for multiple targets with the result of 99.3% ± 0.8%. CONCLUSIONS: The three calibration methods were validated, and they produced accurate calibration curves for EBT-XD films to enable pre-treatment patient-specific QA for stereotactic radiotherapy.


Assuntos
Dosimetria Fotográfica , Radiocirurgia , Humanos , Calibragem , Dosimetria Fotográfica/métodos , Dosagem Radioterapêutica , Radiocirurgia/métodos , Imagens de Fantasmas
12.
Radiat Prot Dosimetry ; 199(19): 2391-2395, 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-37609988

RESUMO

In recent years, radiochromic films have begun to be used for dosimetry in mammography; however, the most sensitive GAFCHROMIC XR-QA2 (XR-QA2) film is no longer available owing to its discontinuation. In this study, we evaluated the sensitivity characteristics of GAFCHROMIC LD-V1 (LD-V1) as an alternative to XR-QA2 in the field of mammography, at a low dose and low energy. Our results show that the average ratio of the concentration change of LD-V1 divided by the concentration change of XR-QA2 at each absorbed dose was 53.7%, indicating the sensitivity of LD-V1 to be approximately half of XR-QA2. In addition, the linearity of the concentration change is sufficient even within a dose range of 0.59-14.52 mGy, which is lower than the manufacturer's recommended dose range. Therefore, the LD-V1 is capable of accurate dose assessment even with a low dose and the low level of energy used in mammography.


Assuntos
Dosimetria Fotográfica , Radiometria , Doses de Radiação , Dosimetria Fotográfica/métodos , Calibragem , Mamografia
13.
J Appl Clin Med Phys ; 24(8): e13947, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37408167

RESUMO

PURPOSE: We validate the routine use of a two-dimensional (2D) diode matrix for patient specific pre-treatment verification for Cyberknife (CK) stereotactic radiosurgery and to compare it with film dosimetry. MATERIALS AND METHOD: A total of 46 patients were selected according to the most frequent diseases treated at our institution with the CK system, that is, brain metastases, meningiomas, spine metastases, and prostate tumors. All cases were evaluated with GAFChromic EBT-3 films and SRS MapCHECK for Fixed cone, IRIS, and MLC collimators of the CK. RESULTS: The highest mean passing rate was observed for the SRS MapCHECK system compared to films. In order to assess if the two techniques provide statistically different results, a Wilcoxon Signed-Rank non-parametric test was performed (p < 0.05) and we found gamma values significantly lower for EBT-3 films with respect to the SRS MapCHECK. We noticed a moderately significant association between the two techniques using Spearman's rank correlation coefficient (rs > 0.4). We also performed the Bland-Altman statistical method: less than 5% of the differences resulted outside the range (mean ± 1.96 × SD), so the two methods can be considered interchangeable within the combined inaccuracy. CONCLUSIONS: The use of SRS MapCHECK for CK patient specific quality assurance (QA) is feasible for a variety of clinical districts and could be reliably used as a replacement for radiochromic films.


Assuntos
Neoplasias Encefálicas , Neoplasias da Próstata , Radiocirurgia , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Radiocirurgia/métodos , Dosimetria Fotográfica/métodos , Dosagem Radioterapêutica
14.
Phys Med Biol ; 68(17)2023 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-37499683

RESUMO

Objective.To evaluate a new film for radiotherapy dosimetry, Gafchromic EBT4, compared to the current EBT3. To evaluate dose-response and verify test cases in MV external beam and HDR brachytherapy.Approach. Three lots (batches) of EBT4 and three lots of EBT3 films were calibrated at 6 MV over 0-1200 cGy range, using FilmQAPro software. Signal-to-noise of pixel value, reported dose (RD), and factors affecting dosimetry accuracy were evaluated (rotation of the film at scanning, energy response and post-exposure darkening). Both films were exposed to clinical treatment plans (VMAT prostate, SABR lung, single HDR source dwell, and 'pseudo' 3-channel HDR cervix brachytherapy). Film-RD was compared to TPS-calculated dose.Main results.EBT4 calibration curves had characteristics more favourable than EBT3 for radiation dosimetry, with improved signal to noise in film-RD of EBT4 compared to EBT3 (increase of average 46% in red and green channels at 500 cGy). Film rotation at scanning and post-exposure darkening was similar for the two films. The energy response of EBT4 is similar to EBT3. For all clinical case studies, EBT4 provided better agreement with the TPS-planned doses than EBT3. VMAT prostate gamma 3%/3 mm passing rate, EBT4 100.0% compared to EBT3 97.9%; SABR lung gamma 2%/2 mm, EBT4 99.6% and EBT3 97.9%; HDR cervix gamma 3%/2 mm, EBT4 97.7% and EBT3 95.0%.Significance.These results show EBT4 is superior to EBT3 for radiotherapy dosimetry validation of TPS plan delivery. Fundamental improvements in noise profile and calibration curve are reported for EBT4. All clinical test cases showed EBT4 provided equivalent or smaller difference in measured dose to TPS calculated dose than EBT3. Baseline data is presented on the achievable accuracy of film dosimetry in radiotherapy using the new Gafchromic EBT4 film.


Assuntos
Braquiterapia , Dosímetros de Radiação , Feminino , Humanos , Dosagem Radioterapêutica , Radiometria , Software , Braquiterapia/métodos , Dosimetria Fotográfica/métodos , Calibragem
15.
Phys Med ; 109: 102587, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37087865

RESUMO

PURPOSE: To evaluate the applicability of microdosimetric kinetic model (MKM) to helium-ion therapy by forming a spread-out Bragg peak (SOBP) of a helium-ion beam using the MKM developed for carbon-ion radiotherapy and confirming the predictions in biological experiments. METHODS: Using a ridge filter, a 90-mm wide SOBP for a 210 MeV/u helium-ion beam was created in a broad beam delivery system. The ridge filter was designed such that a uniform biological response was achieved with a cell survival rate of 7% over the SOBP region. Biological experiments were then performed using the SOBP beam in a human salivary gland (HSG) cell line to measure the cell survival rates. RESULTS: The biological responses were uniform in the SOBP region, as expected by the MKM; however, the mean of the measured cell survival rates was (11.2 ± 0.6) % in the SOBP region, which was 60% higher than the designed rate. When investigating the biological parameters of the HSG cell line used in the experiments, we found that they were altered slightly from the MKM parameters used for carbon-ion radiotherapy. The new ß parameter reproduced the measured survival rates within 6.5% in the SOBP region. CONCLUSION: We produced biologically uniform SOBP using MKM for carbon-ion radiotherapy. The measured survival rates in the SOBP region were higher than expected, and the survival rates were reproduced by modifying the MKM parameter. This study was limited to one SOBP, and further investigations are required to prove that MKM is generally applicable to helium-ion radiotherapy.


Assuntos
Modelos Químicos , Hélio/química , Íons/química , Dosimetria Fotográfica , Cinética
16.
Medicina (Kaunas) ; 59(3)2023 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-36984628

RESUMO

Background and Objectives: Quality assurance is an integral part of brachytherapy. Traditionally, radiographic films have been used for source position verification, however, in many clinics, computerized tomography simulators have replaced conventional simulators, and computerized radiography systems have replaced radiographic film processing units. With these advances, the problem of controlling source position verification without traditional radiographic films and conventional simulators has appeared. Materials and Methods: In this study, we investigated an alternative method for source position verification for brachytherapy applications. Source positions were evaluated using Gafchromic™ RTQA2 and EBT3 film and visually compared to exposed RTQA radiochromic film when using a Nucletron Oldelft Simulix HP conventional simulator and a Gammamed 12-i brachytherapy device for performance evaluation. Gafchromic film autoradiography was performed with a linear accelerator (LINAC) on-board imager (OBI). Radiochromic films are very suitable for evaluation by visual inspection with a LINAC OBI. Results: The results showed that this type of low-cost, easy-to-find material can be used for verification purposes under clinical conditions. Conclusions: It can be concluded that source-position quality assurance may be performed through a LINAC OBI device.


Assuntos
Braquiterapia , Dosimetria Fotográfica , Humanos , Dosagem Radioterapêutica , Dosimetria Fotográfica/métodos , Braquiterapia/métodos , Tomografia Computadorizada por Raios X
17.
Phys Med ; 107: 102561, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36898300

RESUMO

PURPOSE: To fully characterize the flat panel detector of the new Sphinx Compact device with scanned proton and carbon ion beams. MATERIALS AND METHODS: The Sphinx Compact is designed for daily QA in particle therapy. We tested its repeatability and dose rate dependence as well as its proportionality with an increasing number of particles and potential quenching effect. Potential radiation damage was evaluated. Finally, we compared the spot characterization (position and profile FWHM) with our radiochromic EBT3 film baseline. RESULTS: The detector showed a repeatability of 1.7% and 0.9% for single spots of protons and carbon ions, respectively, while for small scanned fields it was inferior to 0.2% for both particles. The response was independent from the dose rate (difference from nominal value < 1.5%). We observed an under-response due to quenching effect for both particles, mostly for carbon ions. No radiation damage effects were observed after two months of weekly use and approximately 1350 Gy delivered to the detector. Good agreement was found between the Sphinx and EBT3 films for the spot position (central-axis deviation within 1 mm). The spot size measured with the Sphinx was larger compared to films. For protons, the average and maximum differences over different energies were 0.4 mm (3%) and 1 mm (7%); for carbon ions they were 0.2 mm (4%) and 0.4 mm (6%). CONCLUSIONS: Despite the quenching effect the Sphinx Compact fulfills the requirements needed for constancy checks and could represent a time-saving tool for daily QA in scanned particle beams.


Assuntos
Terapia com Prótons , Prótons , Radiometria , Carbono , Dosimetria Fotográfica
18.
Biomed Phys Eng Express ; 9(3)2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36796085

RESUMO

Purpose. Films and TLDs have been the common choices for passivein-vivodose measurement in radiotherapy. In the brachytherapy applications, it is very difficult to report and verify the dose at multiple localized high dose gradient regions and also the dose to organ at risk. This study was carried out to introduce a new and accurate calibration method for GafChromic EBT3 films irradiated using Ir-192 photon energy from miniature High Dose Rate (HDR) Brachytherapy source.Materials and methods. Film holder made of Styrofoam was used to hold the EBT3 film at its center. It was placed inside the mini water phantom and the films were irradiated by Ir-192 source of microSelectron HDR afterloading brachytherapy system. Two different setups: Single catheter-based film exposure and dual catheter-based film exposure were compared. The films scanned on a flatbed scanner were analysed in three different color channels: red, green, and blue using Image J software. The dose calibration graphs were generated using the third-order polynomial equations fitted on the data points from two different methods of calibration procedure. Maximum and mean dose difference between TPS calculated and measured was analyzed.Results. The measured dose difference from the TPS calculated doses were evaluated for the three groups of dose ranges (low, medium and high). In the high dose range, standard uncertainty of dose difference are ±2.3%, ±2.9%, and ±2.4% respectively for the red, green, and blue color channel when the TPS calculated dose was compared with single catheter based film calibration equation. Whereas it is observed as 1.3%, 1.4% and 3.1% for the red, green, and blue color channels respectively when compared with the dual catheter based film calibration equation. A test film was exposed to a TPS calculated dose of 666 cGy to validate the calibration equations, single catheter based film calibration equation estimated the dose difference as -9.2%, -7.8% and -3.6% respectively in the red, green, and blue color channels whereas the same were observed as 0.1%, 0.2% and 6.1% respectively when dual catheter based film calibration equation was applied.Conclusion.Source miniature size, reproducible positioning of the film and catheter system inside water medium are the major challenges in the film calibration with Ir-192 beam. To overcome these situations dual catheter-based film calibration was found more accurate and reproducible as compare to the single catheter based film calibration.


Assuntos
Dosimetria Fotográfica , Radioisótopos de Irídio , Calibragem , Dosimetria Fotográfica/métodos , Catéteres , Água
19.
Med Phys ; 50(6): 3738-3745, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36695666

RESUMO

BACKGROUND: EBT4 was newly released for radiotherapy quality assurance to improve the signal-to-noise ratio in radiochromic film dosimetry. It is important to know its dose-response characteristics before its use in the clinic. PURPOSE: This study aims to investigate and compare the dose-response curves of the Gafchromic EBT4 film for megavoltage and kilovoltage x-ray beams with different dose levels, scanning spatial resolutions, and sizes of region of interest (ROI). METHODS: EBT4 film (Lot#07052201) calibration strips (3.5 × 20 cm2 ) were exposed to a 10×10 cm2 open field at doses of 0, 63, 125, 500, 750, 1000 cGy using 6 MV photon beam. EBT4 film strips from the same lot were then exposed to each x-ray beam (6 MV, 6 MV FFF, 10 MV FFF, 15 MV, and 70 kV) at six dose values (50, 100, 300, 600, 800, 1000 cGy). A full sheet (25 × 20 cm2 ) of EBT4 film was irradiated at each energy with 300 cGy for profile comparison with the treatment planning calculation. At two different spatial resolutions of 72 and 300 dpi, each film piece was scanned three consecutive times in the center of an Epson 10000XL flatbed scanner in 48-bit color. The scanned images were analyzed using FilmQA Pro. For each scanned image, an ROI of 2 × 2 cm2 at the field center was selected to obtain the average pixel value with its standard deviation in the ROI. An additional ROI of 1 cm diameter circle was also used to evaluate the impact of ROI shape and size, especially for FFF beams. The dose value, average dose-response value, and associated uncertainty were determined for each energy and relative responses were analyzed. The Student's t-test was performed to evaluate the statistical significance of the dose-response values with different color channels, ROI shapes, and spatial resolutions. RESULTS: The dose-response curves for the five x-ray energies were compared in three color channels. Weak energy dependence was found among the megavoltage beams. No significant differences (average ∼1.1%) were observed for all doses in this study among 6 MV, 6 MV FFF, 10 MV FFF, and 15 MV beams, regardless of spatial resolution and color channel. However, a statistically significant difference in dose-response was observed up to 12% between 70 kV and 6 MV beams. CONCLUSIONS: The dose-response curves for Gafchromic EBT4 films were nearly independent of the energy of the photon beams among 6 MV, 6 MV FFF, 10 MV FFF, and 15 MV. For very low-energy photons (e.g., 70 kV), a separate calibration from the same low-energy x-ray is necessary.


Assuntos
Dosimetria Fotográfica , Fótons , Humanos , Raios X , Radiografia , Dosimetria Fotográfica/métodos , Calibragem
20.
Med Biol Eng Comput ; 61(2): 435-444, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36460872

RESUMO

A buildup bolus is used during the post-mastectomy radiotherapy (PMRT) to overcome under-dosage issues in the chest wall. The current study is aimed at evaluating the performance of a bolus in dose enhancement through both film dosimetry and treatment planning approaches. Twenty patients were enrolled in current research. The received dose by the skin at the lateral and medial regions of the chest wall in the presence and absence bolus was evaluated. Film dosimetry results showed that the presence of the bolus can averagely increase the skin dose by about 80% (P value < 0.001) and 92% (P value < 0.001) in lateral and medial regions, respectively. No significant difference was observed between the measured and treatment planning system (TPS)-calculated dose values in the presence of bolus. The presence of the bolus can considerably increase the absorbed dose by superficial chest wall regions. The TPS shows a favorable performance in superficial dose calculations in the presence of the buildup bolus. Hosseini et al.: demonstration of implemented research in the current study.


Assuntos
Neoplasias da Mama , Dosimetria Fotográfica , Humanos , Feminino , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Mastectomia , Planejamento da Radioterapia Assistida por Computador , Pele , Dosagem Radioterapêutica