Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Catheter Cardiovasc Interv ; 91(7): E68-E71, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-28029208

RESUMO

A 26-year-old female with carcinoid heart disease consisting of severe pulmonary and tricuspid valve stenosis was admitted with line associated sepsis. She recovered from sepsis with antibiotics and aggressive fluid resuscitation but became grossly volume overloaded with evidence of tense ascites and lower extremity edema. She developed worsening renal and hepatic function due to congestive nephropathy and hepatopathy, which did not respond to intravenous diuretics, and she was deemed too sick for surgical pulmonary and tricuspid valve replacement. Pulmonary and tricuspid valvuloplasty was performed as a rescue measure to alleviate her congestive symptoms and improve her candidacy for valve replacement. © 2016 Wiley Periodicals, Inc.


Assuntos
Valvuloplastia com Balão , Doença Cardíaca Carcinoide/terapia , Estenose da Valva Pulmonar/terapia , Estenose da Valva Tricúspide/terapia , Adulto , Doença Cardíaca Carcinoide/diagnóstico por imagem , Doença Cardíaca Carcinoide/fisiopatologia , Ecocardiografia Doppler em Cores , Feminino , Humanos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Estenose da Valva Tricúspide/diagnóstico por imagem , Estenose da Valva Tricúspide/fisiopatologia
2.
J Vet Intern Med ; 31(2): 311-315, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28220526

RESUMO

BACKGROUND: There are limited reports of severe tricuspid valve stenosis in dogs and limited data regarding treatment and outcome. OBJECTIVE: To evaluate clinical signs, echocardiographic features, and outcome of balloon valvuloplasty (BV) in dogs with severe tricuspid valve stenosis (TVS) in which BV was attempted. ANIMALS: Five client-owned dogs with severe TVS. METHODS: Records were retrospectively reviewed and data collected regarding signalment, clinical signs, diagnostic findings, procedures, and outcome. RESULTS: All dogs were Labrador Retrievers. Presenting complaints included episodic weakness/syncope (4/5), abdominal distension (4/5), lethargy (2/5), and exercise intolerance (2/5). The median and range of measurements before BV were as follows: TV mean velocity 1.5 m/s (range 1.4-1.7 m/s); velocity-time integral (VTI) 79.8 cm (42.4-99.1 cm); and TV maximum velocity 2.9 m/s (2.3-3.2 m/s). Measurements (available for 3 of 5 dogs) after BV were as follows: TV mean velocity 1.15 m/s (0.9-1.4 m/s); VTI 44.95 cm (41.4-54.8 cm); and TV maximum velocity 1.15 m/s (1.9-2.3 m/s). The procedure was attempted in all dogs and completed in 4/5 dogs. The largest balloon diameter ranged from 15 mm to 25 mm, and length ranged from 4 cm to 5 cm. Right atrial pressure decreased in 4/5 dogs. All but 1 dog had clinical improvement after BV, but recurrence of clinical signs occurred (2/5). Tricuspid regurgitation worsened in 1 dog culminating in right heart failure and euthanasia. CONCLUSIONS AND CLINICAL IMPORTANCE: BV can be an effective treatment; however, clinical signs can recur. Right heart failure due to worsened TR is a potential complication in dogs with pre-existing moderate-to-severe TR.


Assuntos
Valvuloplastia com Balão/veterinária , Doenças do Cão/terapia , Estenose da Valva Tricúspide/veterinária , Animais , Cães , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/veterinária , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Estenose da Valva Tricúspide/terapia
3.
Catheter Cardiovasc Interv ; 89(3): E84-E89, 2017 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-27528537

RESUMO

Percutaneous valved stent implantation is precluded in small infants because large delivery sheaths and large devices. We describe a procedure in a 1-year-old boy in whom a 19 mm Epic™ valve in tricuspid position had become dysfunctional. As the internal diameter of the prosthetic valve was about 16 mm, the only available valve was the Melody™ valved stent. Technical modifications were required to address issues like venous access, the bulky delivery system, and the length of the valved stent. The Melody™ valved stent was surgically trimmed and mounted on a 16 mm Tyshak balloon, access was provided transhepatically through a short 18 Fr sheath. After deployment, the intrahepatic route was sealed with two vascular plugs (8 and 10 mm) in tandem. The procedure was uncomplicated with perfect valve function 18 months after implant. © 2016 Wiley Periodicals, Inc.


Assuntos
Bioprótese , Cateterismo Cardíaco/instrumentação , Cateterismo Periférico/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Veias Hepáticas , Stents , Insuficiência da Valva Tricúspide/terapia , Estenose da Valva Tricúspide/terapia , Valva Tricúspide/cirurgia , Valvuloplastia com Balão , Cateterismo Cardíaco/métodos , Anuloplastia da Valva Cardíaca , Ecocardiografia Doppler em Cores , Ecocardiografia Doppler de Pulso , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Lactente , Masculino , Desenho de Prótese , Falha de Prótese , Punções , Recuperação de Função Fisiológica , Recidiva , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/cirurgia , Estenose da Valva Tricúspide/diagnóstico por imagem , Estenose da Valva Tricúspide/etiologia , Estenose da Valva Tricúspide/fisiopatologia
4.
BMJ Case Rep ; 20162016 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-27436036

RESUMO

Spindle cell sarcomas of the right atrium are extremely rare primary cardiac tumours with very few cases reported in the medical literature. The prognosis of this malignant neoplasm remains poor due to delay in diagnosis, early metastasis and few available therapeutic options. It responds poorly to chemotherapy and radiotherapy. Surgical excision is the mainstay of treatment. We report a 42-year-old man, who presented to emergency room with dyspnoea and fatigue (New York Heart Association classification II) since 1 month. Transthoracic echocardiogram showed massive pericardial effusion with tamponade. The patient underwent emergency pericardiocentesis; postpericardiocentesis echocardiogram showed large right atrial mass involving the right ventricle and the tricuspid valve causing tricuspid stenosis. Findings were confirmed by cardiac CT scan. Percutaneous transvenous biopsy was carried out which revealed spindle cell sarcoma.


Assuntos
Neoplasias Cardíacas/complicações , Neoplasias Cardíacas/diagnóstico por imagem , Sarcoma/complicações , Sarcoma/diagnóstico por imagem , Estenose da Valva Tricúspide/diagnóstico por imagem , Estenose da Valva Tricúspide/etiologia , Adulto , Ecocardiografia Transesofagiana , Evolução Fatal , Átrios do Coração/diagnóstico por imagem , Humanos , Pericardiocentese , Tomografia Computadorizada por Raios X , Valva Tricúspide/diagnóstico por imagem , Estenose da Valva Tricúspide/terapia
5.
Catheter Cardiovasc Interv ; 88(3): 456-9, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27015096

RESUMO

Bioprosthetic valves degenerate over time. Transcatheter valve-in-valve procedures have become an attractive alternative to surgery. However, every valve increasingly diminishes the diameter of the valvar orifice. We report a 12-year-old female who had a previous transcatheter tricuspid valve-in-valve procedure; cracking the ring of a Carpentier Edwards Perimount valve by means of an ultrahigh pressure balloon allowed implantation of a further larger percutaneous valve. The advantage of this novel approach permits enlarging the inner valve diameter and may facilitate future interventions and prolong time to surgery. © 2016 Wiley Periodicals, Inc.


Assuntos
Valvuloplastia com Balão , Bioprótese , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Falha de Prótese , Insuficiência da Valva Tricúspide/terapia , Estenose da Valva Tricúspide/terapia , Valva Tricúspide/cirurgia , Cateterismo Cardíaco/métodos , Criança , Ecocardiografia Doppler de Pulso , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Pressão , Desenho de Prótese , Radiografia Intervencionista , Recidiva , Retratamento , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/cirurgia , Estenose da Valva Tricúspide/diagnóstico por imagem , Estenose da Valva Tricúspide/fisiopatologia
7.
Gen Thorac Cardiovasc Surg ; 64(10): 618-20, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25702202

RESUMO

A 51-year-old woman was diagnosed as severe stenosed tricuspid bioprosthetic valve. She had developed an encephalopathy due to elevated serum ammonia concentration caused by congestive hepatic failure. Re-tricuspid valve replacement was deemed too risky, and balloon bioprosthetic valvuloplasty was instead planned. This procedure was successfully performed using a standard mitral valvuloplasty protocol. The 30-mm INOUE-BALLOON was inflated five times. The mean pressure gradient across the bioprosthetic valve decreased from 7.8 to 3.5 mmHg, and the tricuspid valve orifice area increased from 1.09 to 3.13 cm(2), without worsening of the tricuspid valve regurgitation. Finally, her hepatic encephalopathy was dramatically improved.


Assuntos
Valvuloplastia com Balão/métodos , Encefalopatia Hepática/terapia , Estenose da Valva Tricúspide/terapia , Bioprótese , Contraindicações , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca , Encefalopatia Hepática/complicações , Humanos , Pessoa de Meia-Idade , Falha de Prótese , Insuficiência da Valva Tricúspide/complicações , Estenose da Valva Tricúspide/complicações
9.
Eur J Cardiothorac Surg ; 42(4): S1-44, 2012 10.
Artigo em Inglês | MEDLINE | ID: mdl-22922698
11.
Catheter Cardiovasc Interv ; 80(3): 474-6, 2012 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-22105855

RESUMO

A transcatheter pulmonary valve (Melody) was implanted within a stenotic biological valve prosthesis in tricuspid position, as an alternative to the fourth major cardiac surgery in a 12-year-old girl. There were no complications. The postinterventional result was very good.


Assuntos
Bioprótese , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Tricúspide/cirurgia , Estenose da Valva Tricúspide/terapia , Valva Tricúspide/cirurgia , Criança , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Desenho de Prótese , Radiografia Intervencionista , Resultado do Tratamento , Estenose da Valva Tricúspide/etiologia
12.
Catheter Cardiovasc Interv ; 80(6): 997-1001, 2012 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-22105983

RESUMO

Percutaneous pulmonary valve implantation has been established as a valuable treatment option for elder children and adolescents with conduit failure in the right ventricular outflow tract. Transcatheter valve implantation in the tricuspid position is restricted to single case reports. A 26-year-old male initially diagnosed with tetralogy of Fallot and hypoplastic pulmonary arteries hitherto underwent a total of five open chest procedures including tricuspid valve replacement with a bioprosthesis and a pulmonary homograft exchange. He now presented with severe right heart failure due to a degenerated pulmonary homograft and calcified, severely stenotic tricuspid bioprosthesis with markedly dilated and reduced right ventricular function. We report on the first successful percutaneous transcatheter double-valve replacement using two Melody valves in the pulmonary and tricuspid position, respectively.


Assuntos
Bioprótese , Calcinose/terapia , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Artéria Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Estenose da Valva Tricúspide/terapia , Valva Tricúspide/cirurgia , Adulto , Calcinose/etiologia , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Artéria Pulmonar/anormalidades , Radiografia Intervencionista , Tetralogia de Fallot/cirurgia , Resultado do Tratamento , Estenose da Valva Tricúspide/etiologia , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/terapia
13.
Ann Thorac Surg ; 91(5): e74-6, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21524436

RESUMO

A 69-year-old man presented with symptoms of right heart failure due to stenosis of a tricuspid valve bioprosthesis. Echocardiography revealed right atrial dilatation and an estimated tricuspid valve area of 0.4 cm2. Because of advanced poor general condition and comorbidities, he was found unfit for conventional reoperation. Instead, transcatheter transatrial stent-valve implantation through a right thoracotomy was scheduled. The procedure resulted in a markedly improved clinical condition and an increased valve area measured to 2.5 cm2. In conclusion, transcatheter transatrial stent-valve implantation in stenotic valves is technically feasible and may lead to substantial improvement of the clinical condition.


Assuntos
Bioprótese/efeitos adversos , Cateterismo Cardíaco/métodos , Oclusão de Enxerto Vascular/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Stents , Estenose da Valva Tricúspide/terapia , Idoso , Ecocardiografia Doppler , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Átrios do Coração , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Qualidade de Vida , Retratamento/métodos , Medição de Risco , Índice de Gravidade de Doença , Resultado do Tratamento , Estenose da Valva Tricúspide/diagnóstico por imagem
14.
J Assoc Physicians India ; 54: 655-6, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16941798

RESUMO

In patients with intractable ascites, careful consideration should be given to the patient's past history with emphasis on cardiac, liver and renal disorders. Ascitic fluid cytology indicating the presence of malignant cells should be unequivocal; cytology should be repeated before embarking on potentially toxic anti-cancer treatment in ambiguous cases. Elevated serum CA-125 levels should not be relied upon to make the diagnosis of ovarian/peritoneal carcinoma. We report a case of tricuspid stenosis with severe ascites in an elderly woman who was initially mis-diagnosed and treated as peritoneal/ovarian carcinoma.


Assuntos
Ascite/diagnóstico , Antígeno Ca-125/sangue , Estenose da Valva Tricúspide/diagnóstico , Ascite/terapia , Cateterismo , Erros de Diagnóstico , Feminino , Próteses Valvulares Cardíacas , Humanos , Pessoa de Meia-Idade , Neoplasias Ovarianas , Neoplasias Peritoneais/diagnóstico , Falha de Prótese , Estenose da Valva Tricúspide/terapia
15.
Echocardiography ; 23(4): 324-8, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16640713

RESUMO

A 52-year-old male with idiopathic hypereosinophilic syndrome (HES) was transferred to our institution following the development of acute respiratory failure and shock. He had previously undergone tricuspid valve replacement with bioprosthetic valves on two occasions: the initial surgery for severe native tricuspid valve stenosis and the redo surgery for severe prosthetic valve stenosis and regurgitation. Conventional imaging assessment using transoesophageal echocardiography was suboptimal and comprehensive assessment of prosthetic valve function was aided by the use of intracardiac echocardiography (ICE). ICE provided high quality 2D imaging of the prosthesis demonstrating thrombus-like material coating the inner surfaces of the prosthetic valve stents effectively forming a tunnel-like obstruction. Unusual hemodynamics secondary to severe tricuspid stenosis were demonstrated by CW Doppler with intermittent "signal fusion" resulting from blunted respiratory variation in the markedly elevated right atrial pressure relative to right ventricular pressure. Successful balloon valvuloplasty was performed with ICE proving highly valuable in guiding balloon position as well as monitoring the efficacy of the subsequent inflations.


Assuntos
Ecocardiografia Doppler , Próteses Valvulares Cardíacas , Síndrome Hipereosinofílica/complicações , Estenose da Valva Tricúspide/terapia , Baixo Débito Cardíaco/etiologia , Cateterismo , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Reoperação , Estenose da Valva Tricúspide/diagnóstico por imagem , Estenose da Valva Tricúspide/etiologia
16.
Rev. argent. cardiol ; 74(1): 72-74, ene.-feb. 2006. graf
Artigo em Espanhol | LILACS | ID: lil-440326

RESUMO

Se presenta el caso de una mujer de 43 años, con antecedentes de fiebre reumática, accidente vasculoencefálico isquémico, estenosis mitral y tricuspídea y disnea en CF III de 2 años de evolución. Se realizó ecocardiografia transesofágica que demostró estenosis mitral severa con área de 0,78 cm² y estenosis tricuspídea severa, con índice de Wilkins de 9/16. Se realizó valvuloplastia bivalvular percutánea con balón, con resultado exitoso. A un año del procedimiento la paciente evoluciona asintomática.


Assuntos
Humanos , Adulto , Feminino , Estenose da Valva Mitral/cirurgia , Estenose da Valva Mitral/diagnóstico , Estenose da Valva Mitral/terapia , Estenose da Valva Mitral , Estenose da Valva Tricúspide/cirurgia , Estenose da Valva Tricúspide/diagnóstico , Estenose da Valva Tricúspide/terapia , Estenose da Valva Tricúspide , Cateterismo , Ecocardiografia Transesofagiana , Eletrocardiografia
19.
J Am Vet Med Assoc ; 220(4): 491-6, 464, 2002 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-11860245

RESUMO

A 3.75-year-old castrated male Chesapeake Bay Retriever was referred for evaluation of tachypnea, exercise intolerance, and cyanosis. Echocardiographically, there was severe tricuspid stenosis and right-to-left atrial-level shunting of blood. Marked compensatory polycythemia had developed; the PCV was 75%. Balloon dilation of the tricuspid stenosis was performed. Subsequent echocardiographic examinations demonstrated a reduction in the pressure gradient across the tricuspid valve. The PCV returned to the reference range, and the dog's clinical status improved during the 12 months after the procedure. Tricuspid stenosis is an uncommon lesion in dogs and, in the dog of this report, was assumed to have resulted from tricuspid dysplasia. Cyanosis was a result of right-to-left shunting of blood. Limited treatment is available for dogs with cyanotic heart disease. In this dog, balloon dilation of the stenotic tricuspid valve was palliative.


Assuntos
Cateterismo/veterinária , Doenças do Cão/terapia , Cuidados Paliativos , Estenose da Valva Tricúspide/veterinária , Angiografia/veterinária , Animais , Doenças do Cão/diagnóstico , Cães , Ecocardiografia/veterinária , Ecocardiografia Doppler em Cores/veterinária , Eletrocardiografia/veterinária , Hematócrito/veterinária , Masculino , Estenose da Valva Tricúspide/diagnóstico , Estenose da Valva Tricúspide/terapia
20.
Cathet Cardiovasc Diagn ; 45(3): 246-50, 1998 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9829880

RESUMO

Although combined mitral and tricuspid stenosis are rarely seen in patients with rheumatic heart disease, when both exist together, combined percutaneous balloon valvuloplasty can be an alternative to surgical treatment in suitable cases. We present the immediate and late follow up results of 12 patients with rheumatic tricuspid and mitral stenosis treated with combined percutaneous balloon valvuloplasty. Twelve patients (11 female, 91.7%; 1 male, 8.3%) with a mean age of 35.3 +/- 6.4 years were enrolled in the study. The patients were followed up for 38.8 +/- 12.6 months. The mitral valve area increased from 1.2 +/- 0.2 cm2 to 2.3 +/- 0.2 cm2 (P < 0.01) and on follow up the mitral valve area did not differ significantly (2.2 +/- 0.2 cm2; P > 0.05). The tricuspid valve area increased from 1.6 +/- 0.3 cm2 to 3.2 +/- 0.2 cm2 (P < 0.01) and on follow up the tricuspid valve area did not differ significantly (3.1 +/- 0.2 cm2; P > 0.05). Two patients (16.6%) had tricuspid restenosis and tricuspid re-valvuloplasty. One other patient (8.3%) was referred to surgery 14 months after the procedure secondary to severe tricuspid regurgitation. In conclusion, this study demonstrates a sustained benefit on late follow up after combined percutaneous balloon valvuloplasty of mitral and tricuspid valves and confirms the efficacy and safety of the procedure as an alternative to surgery in selected cases of combined mitral and tricuspid stenosis.


Assuntos
Cateterismo , Estenose da Valva Mitral/terapia , Estenose da Valva Tricúspide/terapia , Adulto , Cateterismo/efeitos adversos , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca , Hemodinâmica , Humanos , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/terapia , Masculino , Valva Mitral , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/etiologia , Estenose da Valva Mitral/fisiopatologia , Recidiva , Cardiopatia Reumática/complicações , Segurança , Resultado do Tratamento , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/terapia , Estenose da Valva Tricúspide/etiologia , Estenose da Valva Tricúspide/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA