Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.399
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Am Coll Cardiol ; 83(19): 1902-1916, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38719370

RESUMO

Postinfarction ventricular free-wall rupture is a rare mechanical complication, accounting for <0.01% to 0.02% of cases. As an often-catastrophic event, death typically ensues within minutes due to sudden massive hemopericardium resulting in cardiac tamponade. Early recognition is pivotal, and may allow for pericardial drainage and open surgical repair as the only emergent life-saving procedure. In cases of contained rupture with pseudo-aneurysm (PSA) formation, hospitalization with subsequent early surgical intervention is warranted. Not uncommonly, PSA may go unrecognized in asymptomatic patients and diagnosed late during subsequent cardiac imaging. In these patients, the unsettling risk of complete rupture demands early surgical repair. Novel developments, in the field of transcatheter-based therapies and multimodality imaging, have enabled percutaneous PSA repair as a feasible alternate strategy for patients at high or prohibitive surgical risk. Contemporary advancements in the diagnosis and treatment of postmyocardial infarction ventricular free-wall rupture and PSA are provided in this review.


Assuntos
Falso Aneurisma , Ruptura Cardíaca Pós-Infarto , Infarto do Miocárdio , Humanos , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Infarto do Miocárdio/complicações , Ruptura Cardíaca Pós-Infarto/etiologia , Ruptura Cardíaca Pós-Infarto/diagnóstico , Ventrículos do Coração/diagnóstico por imagem , Aneurisma Cardíaco/etiologia , Aneurisma Cardíaco/cirurgia
2.
World J Urol ; 42(1): 280, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38693433

RESUMO

OBJECTIVE: To perform a comprehensive narrative review that will examine the risk factors and treatment outcomes of arterial pseudoaneurysm following laser flexible ureteroscopy (F-URS). METHODS: A retrospective case series and a review of literature was performed. Clinical records from three patients treated for postoperative arterial pseudoaneurysm from January of 2021 to November 2023 were identified. A comprehensive literature review was also performed. The MEDLINE and Scopus databases were searched. The analysis was made by a narrative synthesis. RESULTS: Three cases of postoperative arterial pseudoaneurysm were included, one from our center, one from Dubai, UAE, and one from Barcelona. The literature review identified six case reports, two after endocorporeal laser lithotripsy with thulium fiber laser (TFL) and four with Ho:YAG laser. All cases, from our series and literature review, presented with macroscopic hematuria and used high-power laser settings. All cases were treated by selective embolization. CONCLUSION: Ho:YAG or TFL lasers are both capable of causing arterial pseudoaneurysms following F-URS if high-power settings are used. Selective artery embolization continues to be the treatment of choice with good outcomes.


Assuntos
Falso Aneurisma , Litotripsia a Laser , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Litotripsia a Laser/efeitos adversos , Litotripsia a Laser/métodos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Ureteroscopia/efeitos adversos , Adulto
3.
Kyobu Geka ; 77(5): 364-368, 2024 May.
Artigo em Japonês | MEDLINE | ID: mdl-38720606

RESUMO

A 59-year-old man was admitted to our hospital with left hemiplegia. A computed tomography( CT) scan and echocardiography revealed a cerebral infarction in the right middle cerebral artery's territory, as well as a large pseudoaneurysm (4×3 cm) of the lateral left ventricular wall. The patient agreed to undergo cardiac surgery because of the high risk of rupture and recurrent cerebral infarctions. Owing to the high probability of damaging the posterior papillary muscle and coronary arteries, an extracardiac approach was used, and the pseudoaneurysm cavity was closed using double-patch repair. The patient was discharged from the hospital on the 12th postoperative day without any complications. Both postoperative CT and echocardiography showed closure of the cavity.


Assuntos
Falso Aneurisma , Infarto Cerebral , Ventrículos do Coração , Humanos , Masculino , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Falso Aneurisma/etiologia , Pessoa de Meia-Idade , Infarto Cerebral/etiologia , Infarto Cerebral/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Aneurisma Cardíaco/diagnóstico por imagem , Aneurisma Cardíaco/cirurgia , Aneurisma Cardíaco/etiologia
4.
J Med Case Rep ; 18(1): 191, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38637904

RESUMO

BACKGROUND: Renal artery pseudoaneurysm following partial nephrectomy is a rare entity, the incidence of this entity is more common following penetrating abdominal injuries, percutaneous renal interventions such as percutaneous nephrostomy(PCN) or Percutaneous nephrolithotomy (PCNL). Although rare, renal artery pseudoaneurysm can be life threatening if not managed timely, they usually present within two weeks postoperatively with usual presenting complains being gross haematuria, flank pain and/or anaemia. CASE PRESENTATION: We report case of two female patients 34 and 57 year old respectively of South Asian ethnicity, presenting with renal artery pseudoaneurysm following left sided robot assisted nephron sparing surgery for interpolar masses presenting clinically with total, painless, gross haematuria with clots within fifteen days postoperatively and their successful treatment by digital subtraction angiography and coil embolization. CONCLUSION: Renal artery aneurysm is a rare fatal complication of minimally invasive nephron sparing surgery however considering the preoperative and intraoperative risk factors for its development and prompt suspicion at the outset can be life saving with coil embolization of the bleeding arterial aneurysm.


Assuntos
Falso Aneurisma , Aneurisma , Embolização Terapêutica , Robótica , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Artéria Renal/diagnóstico por imagem , Hematúria/etiologia , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Nefrectomia/efeitos adversos , Embolização Terapêutica/efeitos adversos , Néfrons , Aneurisma/complicações , Aneurisma/cirurgia
5.
Medicine (Baltimore) ; 103(17): e37978, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38669393

RESUMO

RATIONALE: Visceral artery aneurysm is a rare and potentially fatal vascular condition that typically affects the superior mesenteric or inferior mesenteric arteries, the splenic, hepatic, and celiac arteries, as well as their branches. Visceral artery aneurysms can usually be treated using endovascular intervention, open surgery, or percutaneous thrombin injection. PATIENT CONCERNS: A 9-year-old girl was admitted to our trauma center with abdominal and bilateral leg pain after a car accident involving a head-on collision. DIAGNOSIS: Abdominal computed tomography (CT) showed bowel herniation through a muscle defect in the left lateral abdominal wall. There was a small amount of fluid around the liver and spleen, mild thickening of the small bowel wall, and infiltration in the small bowel mesentery, indicating the possibility of small bowel injury. INTERVENTIONS: Emergent exploratory laparotomy was performed. After resection of the ischemic parts of the terminal ileum and sigmoid colon, intestinal continuity was reestablished. Primary repair was performed on a traumatic left lateral abdominal wall hernia. She recovered well postoperatively without any complications. A follow-up abdominal CT scan after 2 months showed a pseudoaneurysm of the ileal branch of the superior mesenteric artery. Despite the absence of any gastrointestinal symptoms, the pseudoaneurysm was treated by endovascular intervention using numerous coils because of the significant risk of delayed rupture or massive bleeding. OUTCOMES: Follow-up abdominal CT scan after 6 months showed complete occlusion and resorption of the pseudoaneurysm. LESSONS: Although it is technically challenging, endovascular coil embolization may be a feasible technique in children with traumatic visceral artery pseudoaneurysms without complications.


Assuntos
Falso Aneurisma , Procedimentos Endovasculares , Artéria Mesentérica Superior , Humanos , Feminino , Criança , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Falso Aneurisma/cirurgia , Artéria Mesentérica Superior/lesões , Artéria Mesentérica Superior/diagnóstico por imagem , Artéria Mesentérica Superior/cirurgia , Procedimentos Endovasculares/métodos , Íleo/irrigação sanguínea , Acidentes de Trânsito , Tomografia Computadorizada por Raios X , Traumatismos Abdominais/complicações , Embolização Terapêutica/métodos
6.
BMJ Case Rep ; 17(4)2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38642934

RESUMO

We present a fatal complication of treatment in a patient with early-onset acromegaly, treated with two transsphenoidal operations, radiotherapy, radiosurgery and pegvisomant. He was diagnosed in his 30s, and controlled from his 40s, with stable residual tumour within the left cavernous sinus. In his 60s, 30 years after surgery/radiotherapy and 14 years after radiosurgery, he developed recurrent episodes of mild epistaxis. A week later, he presented at his local hospital's emergency department with severe epistaxis and altered consciousness. He was diagnosed with a ruptured internal carotid artery (ICA) pseudoaneurysm, but unfortunately died before treatment could be attempted.ICA pseudoaneurysms are rare complications of surgery or radiotherapy and can present with several years of delay, often with epistaxis. This case highlights the importance of life-long monitoring in patients with previous pituitary interventions and early recognition of epistaxis as a herald sign of a potentially catastrophic event, thus leading to timely treatment.


Assuntos
Acromegalia , Falso Aneurisma , Humanos , Masculino , Acromegalia/complicações , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Artéria Carótida Interna , Epistaxe/etiologia , Epistaxe/terapia , Epistaxe/diagnóstico , Hipófise , Idoso
8.
Am J Case Rep ; 25: e942746, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38566390

RESUMO

BACKGROUND RARP is an established procedure in treatment of localized prostate cancer. Hemorrhagic complications in the postoperative period are rare, but sometimes life-threatening. Adequate monitoring and prompt intervention in these unusual scenarios rely on clinical judgement and blood and imaging studies. Prostatic fossa pseudoaneurysm formation after RARP is very rare and its etiology is not well known; it may be related to small vessel trauma. It becomes apparent with the development of hematuria 1-6 weeks after surgery. CASE REPORT A 58-year-old man underwent RARP with extended lymph node dissection for intermediate-risk prostate cancer, with bilateral preservation of neurovascular bundles and puboprostatic ligaments. He was discharged on day 2 without complications. In the following 4 weeks he came to the Emergency Department 3 times with hematuria and acute urinary retention. Four weeks after surgery, a pelvic CT angiogram showed a 20-mm pseudoaneurysm in the prostatic fossa, which was embolized by percutaneous angiography, with resolution of symptoms. He was discharged soon thereafter. CONCLUSIONS This case study describes a patient with prostatic fossa pseudoaneurysm after RARP. It was diagnosed 1 month after surgery and effectively managed by percutaneous embolization. Despite being a very rare condition, it must be kept in mind, especially when postoperative hematuria develops 1-6 weeks after surgery. Use of a management algorithm including serial blood tests, CT angiogram, and percutaneous angiography can lead to early detection and avoid life-threatening hemorrhage and overall postoperative morbidity.


Assuntos
Falso Aneurisma , Neoplasias da Próstata , Robótica , Masculino , Humanos , Pessoa de Meia-Idade , Hematúria/etiologia , Hematúria/cirurgia , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Prostatectomia/efeitos adversos , Prostatectomia/métodos , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/patologia , Resultado do Tratamento
9.
J Med Case Rep ; 18(1): 218, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38658989

RESUMO

BACKGROUND: Postoperative delayed bleeding of gastric cancer is a complication of radical gastrectomy with low incidence rate and high mortality. CASE PRESENTATION: This case report presents the case of a 63-year-old female patient of Mongolian ethnicity who was diagnosed with gastric malignancy during a routine medical examination and underwent Billroth's I gastric resection in our department. However, on the 24th day after the surgery, she was readmitted due to sudden onset of hematemesis. Gastroscopy, abdominal CT, and digital subtraction angiography revealed postoperative anastomotic fistula, rupture of the duodenal artery, and bleeding from the abdominal aorta. The patient underwent three surgical interventions and two arterial embolizations. The patient's condition stabilized, and she was discharged successfully. CONCLUSION: Currently, there are no specific guidelines for the diagnosis and treatment of pseudoaneurysms in the abdominal cavity resulting from gastric cancer surgery. Early digital subtraction angiography examination should be performed to assist in formulating treatment plans. Early diagnosis and treatment contribute to an improved overall success rate of rescue interventions.


Assuntos
Gastrectomia , Hemorragia Pós-Operatória , Neoplasias Gástricas , Humanos , Feminino , Neoplasias Gástricas/cirurgia , Neoplasias Gástricas/complicações , Pessoa de Meia-Idade , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/terapia , Hemorragia Pós-Operatória/diagnóstico , Angiografia Digital , Embolização Terapêutica , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Falso Aneurisma/etiologia , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Tomografia Computadorizada por Raios X , Hematemese/etiologia , Duodeno/irrigação sanguínea , Resultado do Tratamento
10.
BMJ Case Rep ; 17(3)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38521516

RESUMO

A patient in his late 30s presented with issues of retrosternal chest pain and palpitations. He had sustained a splinter injury to the left hemithorax a year ago for which he had been managed with a tube thoracostomy. During subsequent evaluations, he was found to have atrial fibrillations and a CT angiography revealed an arch of the aorta pseudoaneurysm with a fistulous communication with the innominate vein, which being a rare condition has no established treatment protocols. Endovascular salvage of the condition required an aortic Ishimaru zone 2 deployment of the thoracic endovascular aortic repair stent graft to provide an adequate landing zone. The elective left subclavian artery revascularisation was obtained by a left carotid artery to left subclavian artery bypass. Post procedure there was complete exclusion of the pseudoaneurysm sac, and the fistulous aorto-venous communication inflow tract. The patient recuperated well and has returned to full active duties.


Assuntos
Falso Aneurisma , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Traumatismos Torácicos , Humanos , Masculino , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aorta Torácica/lesões , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Veias Braquiocefálicas/diagnóstico por imagem , Veias Braquiocefálicas/cirurgia , Desenho de Prótese , Stents , Traumatismos Torácicos/cirurgia , Resultado do Tratamento , Adulto
11.
Kyobu Geka ; 77(3): 210-212, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38465493

RESUMO

The patient is a 56-year-old man. He fell while playing golf and sustained a contusion on his right chest. He fell into hemorrhagic shock during surgery for a right clavicle fracture at a nearby hospital and required cardiac resuscitation. Computed tomography( CT) scan revealed left pneumothorax and right hemothorax, and a contrast-enhanced CT scan revealed a pseudoaneurysm at the brachiocephalic artery origin. He underwent surgery three weeks later. Surgery was performed through a median sternotomy and partial arch replacement (zone 2) with antegrade cerebral perfusion under moderate hypothermia. He was discharged on postoperative day 10 without significant complications.


Assuntos
Falso Aneurisma , Fraturas Ósseas , Masculino , Humanos , Pessoa de Meia-Idade , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Tomografia Computadorizada por Raios X , Fraturas Ósseas/complicações , Tronco Braquiocefálico/diagnóstico por imagem , Tronco Braquiocefálico/cirurgia , Perfusão
12.
World J Surg ; 48(3): 560-567, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38501570

RESUMO

BACKGROUND: Nonoperative management of abdominal trauma can be complicated by the development of delayed pseudoaneurysms. Early intervention reduces the risk of rupture and decreases mortality. The objective of this study is to determine the utility of repeat computed tomography (CT) imaging in detecting delayed pseudoaneurysms in patients with abdominal solid organ injury. METHODS: A retrospective cohort study reviewing Montreal General Hospital registry between 2013 and 2019. Patients with The American Association for the Surgery of Trauma (AAST) grade 3 or higher solid organ injury following abdominal trauma were identified. A chart review was completed, and demographics, mechanism of injury, Injury Severity Score (ISS) score, AAST injury grade, CT imaging reports, and interventions were collected. Descriptive analysis and logistic regression model were completed. RESULTS: We identified 195 patients with 214 solid organ injuries. The average age was 38.6 years; 28.2% were female, 90.3% had blunt trauma, and 9.7% had penetrating trauma. The average ISS score was 25.4 (SD 12.8) in patients without pseudoaneurysms and 19.5 (SD 8.6) in those who subsequently developed pseudoaneurysms. The initial management was nonoperative in 57.0% of the patients; 30.4% had initial angioembolization, and 12.6% went to the operating room. Of the cohort, 11.7% had pseudoaneurysms detected on repeat CT imaging within 72 h. Grade 3 represents the majority of the injuries at 68.0%. The majority of these patients underwent angioembolization. CONCLUSIONS: In patients with high-grade solid organ injury following abdominal trauma, repeat CT imaging within 72 h enabled the detection of delayed development of pseudoaneurysms in 11.7% of injuries. The majority of the patients were asymptomatic.


Assuntos
Traumatismos Abdominais , Falso Aneurisma , Ferimentos não Penetrantes , Humanos , Feminino , Adulto , Masculino , Estudos Retrospectivos , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Baço/lesões , Traumatismos Abdominais/complicações , Traumatismos Abdominais/diagnóstico por imagem , Traumatismos Abdominais/terapia , Ferimentos não Penetrantes/complicações , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/terapia , Escala de Gravidade do Ferimento
13.
Kyobu Geka ; 77(3): 213-216, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38465494

RESUMO

Formation of a pseudoaneurysm due to blood leakage from the anastomotic site of the vascular graft in large-diameter vessels is often seen, but formation of a pseudoaneurysm from the non-anastomotic site is extremely rare. A 68-year-old woman presented with a history of double valve replacement for combined valvular disease at 37 years old and hemiarch replacement for thoracic aortic dilatation at 65 years old. She visited the emergency room with a 2-week history of chest pain. Contrast-enhanced computed tomography (CT) revealed a 5-cm-diameter pseudoaneurysm and extravasation from the ascending aorta, so emergency surgery was performed. Around the ascending aorta area, we confirmed bleeding from a 5-mm dehiscence in the non-anastomotic part of the graft prosthesis, so hemostasis was performed with a cross-stitch mattress suture over a felt strip. Initially, the cause of the pseudoaneurysm was unknown, but re-examination of CT images from after the previous hemiarch replacement confirmed contact between the sternal wire and graft prosthesis. The wire was thus considered to have caused damage and bleeding. The patient was discharged from the hospital with a good postoperative course and is being followed-up in the outpatient department.


Assuntos
Falso Aneurisma , Implante de Prótese Vascular , Idoso , Feminino , Humanos , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Aorta/cirurgia , Substitutos Sanguíneos , Implante de Prótese Vascular/efeitos adversos
14.
World Neurosurg ; 184: e603-e612, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38336211

RESUMO

BACKGROUND: The optimal stenting approach for traumatic pseudoaneurysms (PSA) of the extracranial internal carotid artery (ICA) remains underinvestigated. We present a case of a traumatic pseudoaneurysm of the extracranial ICA managed with stenting and review of prior published similar cases. METHODS: The systematic review followed PRISMA-S guidelines and included studies that investigated traumatic pseudoaneurysms of the extracranial ICA managed by stent placement. Statistical analysis assessed the association between the type of injury and stent type, dual antiplatelet therapy (DAPT) duration, and clinical presentation, and the association between stent type and DAPT duration. RESULTS: Our search yielded 82 publications with 135 patients with extracranial ICA PSA treated with stenting. The odds of neck hematoma presentation was 12.2 times greater for patients with penetrating rather than blunt injuries (P = 0.000002). Covered stents had 2.02 times higher odds of use for penetrating rather than blunt injuries compared to bare metal stents. (P = 0.0029). Shorter duration DAPT was seen with bare metal stents having 1.25 higher odds of DAPT duration less than one month compared to covered (P = 0.001). CONCLUSIONS: In traumatic extracranial ICA pseudoaneurysms, covered stents are used more commonly for penetrating injuries compared to blunt injuries. Penetrating injuries are more strongly associated with the presentation of a hematoma compared to blunt injuries. Stent type may influence the recommended DAPT duration. Surgeons should consider these findings when selecting stent type and DAPT duration with patients presenting with traumatic extracranial ICA pseudoaneurysm.


Assuntos
Falso Aneurisma , Lesões das Artérias Carótidas , Procedimentos Endovasculares , Ferimentos não Penetrantes , Humanos , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/cirurgia , Lesões das Artérias Carótidas/diagnóstico por imagem , Lesões das Artérias Carótidas/etiologia , Lesões das Artérias Carótidas/cirurgia , Inibidores da Agregação Plaquetária/uso terapêutico , Stents/efeitos adversos , Ferimentos não Penetrantes/complicações , Ferimentos não Penetrantes/cirurgia , Hematoma/complicações , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos
16.
Clin J Gastroenterol ; 17(2): 352-355, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38363445

RESUMO

Hepatic artery pseudoaneurysms have been reported to occur in approximately 1% of cases after metal stenting for malignant biliary obstruction. In contrast, only a few cases have been reported as complications after plastic stenting for benign biliary disease. We report a 61-year-old man with cholangitis who presented with a rare complication of hemobilia after implantation of 7 Fr double pigtail plastic biliary stents. No bleeding was observed approximately one month after biliary stent tube removal. Contrast-enhanced CT scan revealed a circularly enhanced lesion (5 mm in diameter) in the arterial phase at the tip of the previously inserted plastic bile duct stent. Color Doppler ultrasonography enhanced the lesion and detected arterial blood flow inside. He was diagnosed with a hepatic artery pseudoaneurysm. However, he had no risk factors such as prolonged catheterization, severe cholangitis, liver abscess, or long-term steroid use. Superselective transarterial embolization using two metal microcoils was successfully completed without damage to the surrounding liver parenchyma. If hemobilia is suspected after insertion of a plastic bile duct stent, immediate monitoring using contrast-enhanced computed tomography or Doppler ultrasonography is recommended.


Assuntos
Falso Aneurisma , Colangite , Hemobilia , Masculino , Humanos , Pessoa de Meia-Idade , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Hemobilia/terapia , Hemobilia/complicações , Artéria Hepática/diagnóstico por imagem , Artéria Hepática/patologia , Incidência , Colangite/complicações , Stents/efeitos adversos
17.
J Robot Surg ; 18(1): 65, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38329585

RESUMO

Partial nephrectomy (PN) is the gold standard for the resection of amenable small renal masses. Some surgeons have adopted tumor enucleation (TE) over the standard margin PN (SPN) technique based on preservation of healthy renal parenchyma by following the tumor pseudocapsule. However, TE may also confer additional advantages due to avoidance of sharp incision including reduction in perioperative and bleeding complications. Therefore, we evaluated the rate of pseudoaneurysms and other complications following TE vs. SPN. A retrospective cohort study of patients undergoing PN (TE and SPN) between 2008 and 2020 was conducted. Baseline characteristics were compared between the TE and SPN cohorts with univariable and multivariable logistic regression models. A total of 534 patients were included, 195 (36.5%) receiving TE and 339 (63.5%) SPN. There were no differences in baseline patient demographics. There was no difference in RENAL nephrometry scores between the two groups (p = 0.47). TE had lower rates of postoperative complications (11.3 vs. 21.5%, p = 0.002). TE had less bleeding complications (2.1 vs. 8.0%, p = 0.002) with no pseudoaneurysm events following TE compared to 12 following SPN (0.0 vs. 3.5%, p = 0.008). Need for interventional radiology largely reflected pseudoaneurysm differences (0 (0.0%) TE vs. 13 (3.8%) SPN, p = 0.006. Readmission occurred less often after TE vs. SPN (4.1 vs. 8.3%, p = 0.07). Patients receiving TE experienced no clinically significant pseudoaneurysm formation and were less likely to have any bleeding complication or major complication postoperatively. TE may be preferred when minimizing morbidity aligns with patient selection and preferences.


Assuntos
Falso Aneurisma , Neoplasias , Procedimentos Cirúrgicos Robóticos , Humanos , Falso Aneurisma/epidemiologia , Falso Aneurisma/etiologia , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/métodos , Nefrectomia/efeitos adversos
18.
Vasc Endovascular Surg ; 58(5): 567-570, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38240584

RESUMO

Coil migration during endovascular embolization is a complication that can result in thromboembolic occlusion leading to potentially large infarcts if not removed. Microsnares are commonly used to remove migrated coils. Current techniques, however, struggle in cases where the microsnare is unable to loop over and secure a free end of the coil. We present a case in which a microsnare combined with a microwire successfully removed a migrated coil in a patient with a bleeding hepatic pseudoaneurysm post-embolization. This technique proved beneficial when traditional methods were insufficient, especially in small vessels or coil packs that cannot be snared. The synergy of the microsnare and microwire technique presents a promising solution for challenging migrated coil retrievals.


Assuntos
Falso Aneurisma , Remoção de Dispositivo , Embolização Terapêutica , Migração de Corpo Estranho , Humanos , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/terapia , Migração de Corpo Estranho/cirurgia , Embolização Terapêutica/instrumentação , Resultado do Tratamento , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/terapia , Falso Aneurisma/etiologia , Artéria Hepática/diagnóstico por imagem , Masculino , Hemorragia/etiologia , Hemorragia/terapia , Idoso , Desenho de Equipamento , Feminino
19.
Cardiovasc Revasc Med ; 62: 105-118, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38212236

RESUMO

BACKGROUND: Percutaneous closure of aortic and ventricular pseudoaneurysms (PSA) has only been reported on a case report and series basis. In previous case reports, percutaneous closure has been performed successfully in patients of prohibitive surgical risk. This case series aims to show feasibility of percutaneous closure of aortic and ventricular pseudoaneurysm secondary to perivalvular leak (PVL) in a small patient population and the utility of multimodality imaging as an integral tool in procedural planning. This is the largest complex case series to date describing the feasibility and success rate of complex PSA closure, with a follow-up period of up to 4 years. MATERIAL AND METHODS: We performed institutional review and systemic literature review to identify all paravalvular leak cases with associated pseudoaneurysm formation for which a closure procedure was performed. Ten patients were identified. Pooled analysis for cases from institutional review (n = 10) and systemic literature review (n = 39) was performed. The success rate was 100 %. At 30-days, the mortality was 0 %. CONCLUSION: In paravalvular leak patients with subsequent pseudoaneurysm formation, exhaustive imaging evaluation is required for closure. However, it can be achievable with favorable rates of success.


Assuntos
Falso Aneurisma , Implante de Prótese de Valva Cardíaca , Humanos , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Masculino , Feminino , Resultado do Tratamento , Idoso , Pessoa de Meia-Idade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Aneurisma Cardíaco/diagnóstico por imagem , Aneurisma Cardíaco/etiologia , Aneurisma Cardíaco/terapia , Cateterismo Cardíaco/efeitos adversos , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Fatores de Tempo , Idoso de 80 Anos ou mais , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Transesofagiana , Adulto
20.
BMJ Case Rep ; 17(1)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38171642

RESUMO

Bleeding from a visceral artery pseudoaneurysm (VAPA) is a rare but significant complication of bariatric surgery. Patients may present with gastrointestinal (GI) haemorrhage in the forms of haematemesis, melaena, haematochezia or haemodynamic compromise. Although CT angiogram, endoscopy and laparoscopy form essential parts of diagnostic assessment, small pseudoaneurysms with intermittent bleeding may be overlooked. We report the case of a man in his 40s who presented to the emergency department with massive GI bleeding and subsequent haemodynamic instability, secondary to a pseudoaneurysm from a vascular injury during a recent bariatric procedure. This case highlights the diagnostic challenges of obscure, intermittent bleeding involving the bypassed stomach with unremarkable investigation findings, and aims to raise awareness among clinicians in considering the less common postgastric-bypass complications.


Assuntos
Falso Aneurisma , Masculino , Humanos , Falso Aneurisma/etiologia , Falso Aneurisma/complicações , Hemorragia Gastrointestinal/diagnóstico , Hematemese , Melena/etiologia , Artérias
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA