Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Clin Neurol Neurosurg ; 203: 106597, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33725507

RESUMO

OBJECTIVES: Intra-operative fluorescein video angiography (FL-VA) has been given increasing attention recently and several studies reported its high utility in neurovascular surgery. The aim of this study was to evaluate the safety of FL-VA in a prospective, single-center cohort of patients operated due to cerebral aneurysms. PATIENTS AND METHODS: This is an observational cohort study including 150 patients operated due to intracranial aneurysms. The study group consisted of 70 consecutive patients operated with the use of fluorescein video angiography. Post-operative acute kidney injury (AKI) occurrence as well as systemic adverse reactions were reported and further compared with 80 matched controls where FL-VA was not used. Statistical analysis was performed using non-parametric tests (Fisher's exact test). RESULTS: Post-operative AKI was observed in 17,1% of patients in the study group with only half presenting with acute functional impairment. All of these patients presented initially due to aneurysm rupture. Pre-existing renal dysfunction and hypertension occurred in 16,7% and 33,3%, respectively. No systemic complications following FL-VA were reported. When compared to matched controls, no statistically significant difference regarding AKI occurrence was observed between these two patient populations. CONCLUSION: Intra-operative fluorescein video angiography proved to have a good safety profile in our cohort. The results of this study suggest that post-operative acute kidney injury observed in patients with subarachnoid hemorrhage is not related to fluorescein use.


Assuntos
Injúria Renal Aguda/induzido quimicamente , Meios de Contraste/efeitos adversos , Fluoresceína/efeitos adversos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Complicações Pós-Operatórias/induzido quimicamente , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/epidemiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Estudos de Casos e Controles , Angiografia Cerebral , Estudos de Coortes , Feminino , Humanos , Tempo de Internação , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia
2.
Nephrol Dial Transplant ; 36(5): 819-825, 2021 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-31773157

RESUMO

BACKGROUND: Contrast-induced nephropathy (CIN) is a common cause of acute kidney injury (AKI), and can be diagnosed when the etiology of AKI is unclear other than via a contrast agent. Fluorescent angiography (FAG) with fluorescein sodium dye is generally considered to be safe for patients with kidney diseases. However, it remains unresolved whether or not FAG can induce CIN. METHODS: Patients from two tertiary hospitals who underwent FAG and had serum creatinine results within 4 weeks before FAG and 3 days after FAG between 2001 and 2017 were retrieved. Cases with concurrent iodinated contrast imaging or undergoing dialysis were excluded from the analysis. CIN was defined by two criteria: CIN criteria as >0.5 mg/dL or >25% increase in serum creatinine (sCr) level within 3 days after FAG, and contrast-induced acute kidney injury (CIAKI) criteria as ≥0.3 mg/dL increase within 2 days or ≥50% increase within 7 days after FAG. RESULTS: A total of 979 patients were screened, and we found 124 patients with AKI after FAG. After excluding 32 patients with clear causes of AKI other than FAG, the incidence rates of CIN were 7.3% by CIN criteria and 6.4% by CIAKI criteria. CIN incidence had a U-shaped distribution according to chronic kidney disease (CKD) stages in CIN criteria, while linear association between CIN incidence and CKD stages were found in CIAKI criteria. Kaplan-Meier curves showed the CIN group was significantly associated with end-stage renal disease (ESRD) progression (log-rank P < 0.001, in both CIN criteria and CIAKI criteria), and adjusted hazard ratios by multivariable Cox regression were 2.23 [95% confidence interval (CI) 1.468-3.378] in CIN criteria and 2.17 (95% CI 1.462-3.232) in CIAKI criteria. CONCLUSIONS: According to CIN and CIAKI criteria, FAG may cause CIN and appeared to be a possible risk factor for ESRD progression. However, CIN or CIAKI criteria themselves may overestimate AKI and require meticulous attention to the interpretation of results.


Assuntos
Fluoresceína , Injúria Renal Aguda/diagnóstico , Idoso , Meios de Contraste/efeitos adversos , Creatinina/sangue , Fluoresceína/efeitos adversos , Humanos , Incidência , Falência Renal Crônica/complicações , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Diálise Renal , Insuficiência Renal Crônica/complicações , Estudos Retrospectivos , Fatores de Risco
3.
Int Rev Neurobiol ; 151: 139-154, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32448604

RESUMO

OBJECTIVE: Sodium fluorescein (FL) is widely used as a fluorescent tracer for brain tumor resection. However, FL-guided resection of spinal gliomas has been reported only occasionally. To evaluate the safety, characteristics, and usefulness of FL-guided surgery in the resection of spinal glioma. METHODS: Between January 2015 and December 2018, 220 consecutive patients with 227 spinal gliomas underwent FL-guided resection using the Zeiss Pentero 900 surgical microscope with an integrated YELLOW 560 filter. FL evaluation and clinical outcomes were analyzed. RESULTS: No FL-related complications occurred in this series. Entire tumor fluorescence was observed in 161 (70.93%) gliomas, nodular fluorescence in 46 (20.26%) tumors, and no fluorescence in 20 (8.81%) tumors. The intraoperative fluorescence of 217 (95.59%) gliomas was highly correlated with preoperative contrast-enhancing magnetic resonance imaging, except in eight ependymomas, one pilocytic astrocytoma, and one diffuse midline glioma. Gross-total resection was achieved in 78.85% (179/227) of spinal gliomas, including 94.30% (149/158) ependymal tumors and 43.48% (30/69) astrocytic and oligodendroglial tumors. At the final clinical follow-up, the spinal function of 75 (33.04%) patients showed significant improvement, 105 (46.26%) showed stabilization, and 47 (20.70%) showed deterioration. CONCLUSION: FL is a safe and useful real-time tool that could enhance tumor borders or residual tumors and hence increase the gross-total resection rate in cases with contrast-enhanced tumors.


Assuntos
Fluoresceína , Corantes Fluorescentes , Glioma/cirurgia , Procedimentos Neurocirúrgicos/métodos , Avaliação de Processos e Resultados em Cuidados de Saúde , Neoplasias da Medula Espinal/cirurgia , Cirurgia Assistida por Computador/métodos , Adulto , Feminino , Fluoresceína/efeitos adversos , Corantes Fluorescentes/efeitos adversos , Humanos , Imageamento por Ressonância Magnética , Masculino , Microscopia/métodos , Microscopia/normas , Microcirurgia/métodos , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos/efeitos adversos , Procedimentos Neurocirúrgicos/normas
4.
Acta Neurochir (Wien) ; 161(12): 2447-2452, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31679103

RESUMO

BACKGROUND: Schwannomas are the most frequent peripheral nerve sheath tumors and are treated by surgical resection when symptomatic. Tumor removal is performed by intraneural dissection and enucleation. In order to safely remove the tumor from the nerve, the use of sodium fluorescein has recently been proposed to distinguish the tumor from the adjacent normal nerve fibers, before incision of the tumor pseudocapsule and during intraneural tumor dissection. METHODS: We report a consecutive case series of 5 peripheral nerve schwannomas operated in 4 patients, in which we evaluate the usefulness of sodium fluorescein compared to usual visual landmarks, at each step of the surgical procedure. RESULTS: After exposition of the schwannoma, sodium fluorescein helped with the localization of intracapsular en passant nerve fascicles in only one case. Hence, the definition of a safe entry zone for capsular incision relied mainly on nerve monitoring and direct visualization of en passant nerve fascicles under microscope. During intraneural dissection, there was a sharp contrast between the fluorescent tumor and the non-fluorescent adjacent pseudocapsule in most cases but the colorimetric variation between tumor and normal tissue induced by fluorescence did not outperform the natural contrast between the yellow true capsule and the gray-red layers of the pseudocapsule. CONCLUSION: Based on these results, we consider that the limited additional value of sodium fluorescein in primary peripheral nerve schwannoma surgery does not warrant its use in daily clinical practice. Additional studies are needed to assess its usefulness during the surgery of recurrences and tumors which are intertwined with several fascicles of origin such as neurofibromas.


Assuntos
Dissecação/métodos , Fluoresceína/efeitos adversos , Corantes Fluorescentes/efeitos adversos , Neoplasias de Bainha Neural/cirurgia , Neurilemoma/cirurgia , Procedimentos Neurocirúrgicos/métodos , Adulto , Dissecação/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neurofibromatoses , Procedimentos Neurocirúrgicos/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
5.
Turk Neurosurg ; 29(4): 549-554, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30806476

RESUMO

AIM: To investigate the effects of fluorescein-sodium on neural tissues. MATERIAL AND METHODS: Twenty-one Wistar rats were randomly divided into three experimental groups: control (group 1) and fluorescein-sodium groups with different doses (groups 2 and 3). In the control group, craniectomy following with durotomy was performed with the help of a loupe microscope, and a dry sponge was overlayed to the brain tissue. In the study groups, the open dura was covered with a sponge soaked with 0.02 mg (group 2) and with 0.2 mg (group 3) fluorescein sodium following craniectomy. Three weeks postoperatively, rats were sacrificed for the histopathologic evaluations. RESULTS: Fluorescein-induced apoptosis occurs in a dose-dependent manner in rats' neurons. It was determined that neuron and neuroglial cell TUNEL staining was statistically different among the three groups (p < 0.001). Our results indicated that fluorescein induces apoptosis, resulting in increased nuclear factor kappa beta (NF-kß) expression in a dose-dependent manner. CONCLUSION: Fluorescein sodium is used frequently during surgery for CSF fistulas. However, information in the literature about its safety is insufficient. Our study holds promise for the development of new studies on the reliability of this agent.


Assuntos
Apoptose/efeitos dos fármacos , Meios de Contraste/administração & dosagem , Fluoresceína/administração & dosagem , Animais , Apoptose/fisiologia , Meios de Contraste/efeitos adversos , Relação Dose-Resposta a Droga , Dura-Máter/efeitos dos fármacos , Dura-Máter/patologia , Fluoresceína/efeitos adversos , Injeções Espinhais , Masculino , Neurônios/efeitos dos fármacos , Neurônios/patologia , Ratos , Ratos Wistar , Reprodutibilidade dos Testes
6.
Clin Neurol Neurosurg ; 175: 57-60, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30384117

RESUMO

OBJECTIVES: The extent of resection is an independent predictor of prognosis in patients with glioblastomas. Although fluorescein sodium may enhance intraoperative visualization of tumor margin and increase the extent of glioblastoma, the dose related anaphylactic reaction is still a major concern. In the present study, we used allergy skin testing to exclude the patients susceptible to anaphylaxis preoperatively, and then investigated the feasibility of low-dose fluorescein sodium to guide glioblastoma resection intraoperatively, thereby to improve the safety of fluorescein-guided glioma resection. PATIENTS AND METHODS: Patients with suspected glioblastoma based on brain MRI were subjected to allergy skin intradermal tests for fluorescein sodium preoperatively. Only those with negative allergy skin tests received intravenous injection of low dose fluorescein sodium (1-2 mg/kg) during microsurgical tumor resection under dedicated Yellow 560 filter. The degree of fluorescent staining was documented and the extent of resection was evaluated by MRI scan. RESULTS: One patient with positive allergy skin test was excluded from fluorescein sodium administration and no anaphylactic reaction was found during fluorescein sodium guided surgery in the patients who were negative for allergy skin tests. The low dose fluorescein sodium (1-2 mg/kg) could provide enough visualization of tumors with sufficient discrimination from surrounding normal brain tissue and improve the resection extent of glioblastoma. CONCLUSION: Preoperative allergy skin test is a useful method to exclude the patients susceptible to anaphylaxis, together with intraoperative low dose fluorescein sodium administration, may facilitate glioblastoma resection by fluorescence guidance while avoid safety concern of dose-related anaphylaxis.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Fluoresceína/administração & dosagem , Corantes Fluorescentes/administração & dosagem , Glioblastoma/diagnóstico por imagem , Glioblastoma/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Anafilaxia/induzido quimicamente , Anafilaxia/prevenção & controle , Estudos de Coortes , Estudos de Viabilidade , Feminino , Fluoresceína/efeitos adversos , Corantes Fluorescentes/efeitos adversos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios/métodos , Estudos Retrospectivos , Testes Cutâneos/métodos
7.
PLoS One ; 13(10): e0204288, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30303976

RESUMO

Water soluble "vital" dyes are commonly used clinically to evaluate health of the ocular surface; however, staining mechanisms remain poorly understood. Recent evidence suggests that sublethal damage stimulates vital dye uptake by individual living cells. Since cell damage can also stimulate reparative plasma membrane remodeling, we hypothesized that dye uptake occurs via endocytic vesicles. In support of this idea, we show here that application of oxidative stress to relatively undifferentiated monolayer cultures of human corneal epithelial cells stimulates both dye uptake and endocytosis, and that dye uptake is blocked by co-treatment with three different endocytosis inhibitors. Stress application to stratified and differentiated corneal epithelial cell cultures, which are a better model of the ocular surface, also stimulated dye uptake; however, endocytosis was not stimulated, and two of the endocytosis inhibitors did not block dye uptake. The exception was Dynasore and its more potent analogue Dyngo-4a, both small molecules developed to target dynamin family GTPases, but also having off-target effects on the plasma membrane. Significantly, while Dynasore blocked stress-stimulated dye uptake at the ocular surface of ex vivo mouse eyes when treatment was performed at the same time as eyes were stressed, it had no effect when used after stress was applied and the ocular surface was already damaged. Thus, Dynasore could not be working by inhibiting endocytosis. Employing cytotoxicity and western blotting assays, we went on to demonstrate an alternative mechanism. We show that Dynasore is remarkably protective of cells and their surface glycocalyx, preventing damage due to stress, and thus precluding dye entry. These unexpected and novel findings provide greater insight into the mechanisms of vital dye uptake and point the direction for future study. Significantly, they also suggest that Dynasore and its analogues might be used therapeutically to protect the ocular surface and to treat ocular surface disease.


Assuntos
Células Epiteliais/citologia , Olho/citologia , Corantes Fluorescentes/efeitos adversos , Hidrazonas/farmacologia , Estresse Oxidativo/efeitos dos fármacos , Substâncias Protetoras/farmacologia , Animais , Linhagem Celular , Modelos Animais de Doenças , Endocitose/efeitos dos fármacos , Células Epiteliais/efeitos dos fármacos , Olho/efeitos dos fármacos , Fluoresceína/efeitos adversos , Humanos , Camundongos , Técnicas de Cultura de Órgãos , Rosa Bengala/efeitos adversos
8.
Rev. bras. oftalmol ; 77(4): 194-196, jul.-ago. 2018. tab
Artigo em Português | LILACS | ID: biblio-959104

RESUMO

RESUMO Objetivos: Analisar a prevalência da microbiota nos tonômetros de aplanação de Goldmann nos consultórios do SUS e definir o grau de contaminação dos tonômetros e a eficácia da assepsia do cone do tonômetro de aplanação. Métodos: Estudo transversal em que foi realizado a coleta de 60 "swabs", divididos nos três tonômetros de aplanação dos ambulatórios do SUS em dois momentos distintos. No primeiro realizou-se a coleta no início dos atendimentos e no segundo momento, a coleta foi realizada ao final de todos os atendimentos. Todos "swabs" foram colhidos no meio Stuart e foi realizada a cultura em meio de bactérias. Resultados: Das 60 amostras, apenas uma apresentou crescimento de agente patogênico, a Escherichia coli. Conclusão: Independente dos vários métodos que o oftalmologista escolher para realizar a assepsia, a mesma é imprescindível para a manutenção de uma boa saúde ocular do paciente, evitando assim a transmissão e propagação de patógenos por meio do exame oftalmológico e concluímos também que o método utilizado pelo nosso serviço parece ser eficaz nesta profilaxia.


ABSTRACT Objective: Analyze the microbiota prevalence in the Goldmann applanation tonometers in the clinic of the SUS to define the contamination of the tonometers and the efficacy of asepsis of the applanation tonometer cone. Methods: A cross-sectional study was carried out to collect 60 "swabs" divided into the three aplanation tonometers of SUS clinics at two different times. In the first one, the collection will be performed at the beginning of the visits and at the second moment, the collection will be performed at the end of all the visits. All swabs will be harvested in the Stuart medium and culture was carried to sow bacteria. Results: Of the 60 samples, only one showed pathogen growth, Escherichia coli. Conclusion: Regardless of the various ways the ophthalmologist chooses to perform asepsis, it is essential for the maintenance of good patient eye health, thus avoiding the transmission and propagation of pathogens through ophthalmologic examination, and we also conclude that the method used by our patient seems to be effective in this prophylaxis.


Assuntos
Bactérias/isolamento & purificação , Bactérias/crescimento & desenvolvimento , Tonometria Ocular/instrumentação , Contaminação de Equipamentos , Escherichia coli/isolamento & purificação , Escherichia coli/crescimento & desenvolvimento , Tonometria Ocular/efeitos adversos , Assepsia/métodos , Glaucoma/diagnóstico , Contaminação de Medicamentos/estatística & dados numéricos , Estudos Transversais , Técnicas Bacteriológicas , Reutilização de Equipamento , Fluoresceína/efeitos adversos , Meios de Cultura , Fômites/microbiologia , Pressão Intraocular
9.
Obstet Gynecol ; 131(4): 727-729, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29528930

RESUMO

BACKGROUND: Rates of administration of intravenous sodium fluorescein during cystoscopy have increased since indigotindisulfonate sodium was removed from the market in 2014. Although sodium fluorescein has been extensively evaluated and found to be safe, side effects including anaphylaxis have been observed, with an incidence between 0.05% and 1.0%. CASE: We present a case of anaphylactic shock after administration of intravenous sodium fluorescein for the assessment of ureteral efflux in a patient with a history of frequent severe allergic reactions undergoing urethral lysis and cystoscopy for urinary retention. Cardiopulmonary structure and function were evaluated and found to be normal. An elevated serum tryptase level was identified, indicating an anaphylactoid reaction. Timely recognition of symptoms associated with a severe allergic reaction in the setting of hemodynamic instability with prompt supportive and pharmacologic therapy was vital in the patient's recovery. CONCLUSION: Health care providers must be aware of this potential complication, especially in patients with a history of severe allergic reactions.


Assuntos
Anafilaxia/induzido quimicamente , Cistoscopia , Fluoresceína/efeitos adversos , Administração Intravenosa , Feminino , Fluoresceína/administração & dosagem , Humanos , Pessoa de Meia-Idade
10.
Saudi J Kidney Dis Transpl ; 28(3): 491-498, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28540884

RESUMO

Fluorescein angiography (FA) is an important tool for the diagnosis and management of diabetic retinopathy. However, the safety of fluorescein sodium on renal functions is not fully understood. One hundred type 2 diabetes patients, within the Ophthalmology Outpatient Clinic at Alexandria Main University Hospital, Egypt, were enrolled in this prospective observational study to determine the safety of FA on renal function. Serum creatinine and cystatin C were measured pre- and 2 days post-FA. Urinary neutrophil gelatinase-associated lipocalin (uNGAL) was measured pre- and 4 hours post-FA. Renal injury was defined as a 25% increase in serum creatinine, cystatin C, or uNGAL. The study included 71 females and 29 males, with a mean age of 55.73 ± 7.29 years. Baseline serum cystatin C and uNGAL were 0.89 ± 0.34 mg/L and 21.7 ± 2.39 ng/mL, respectively. Serum cystatin C and uNGAL significantly increased after FA to 0.95 ± 0.36 and 27 ± 2.81, respectively (P <0.001). Eleven patients (11%) experienced more than a 25% rise in serum cystatin C from baseline, whereas 40 patients (40%) experienced more than a 25% increase in uNGAL levels after FA. However, the mean serum creatinine level did not change significantly after FA (P = 0.061). Only one patient experienced more than a 25% rise in serum creatinine from baseline. FA showed a significant increase in early sensitive acute kidney injury biomarkers (as serum cystatin C and uNGAL) in substantial number of patients, suggesting but still not proving, a potential harmful effect of FA on kidney functions. These findings were not demonstrated using ordinary serum creatinine.


Assuntos
Injúria Renal Aguda/induzido quimicamente , Diabetes Mellitus Tipo 2/complicações , Retinopatia Diabética/diagnóstico por imagem , Angiofluoresceinografia/efeitos adversos , Fluoresceína/efeitos adversos , Corantes Fluorescentes/efeitos adversos , Rim/efeitos dos fármacos , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/fisiopatologia , Biomarcadores/sangue , Biomarcadores/urina , Creatinina/sangue , Cistatina C/sangue , Diabetes Mellitus Tipo 2/diagnóstico , Retinopatia Diabética/etiologia , Egito , Feminino , Humanos , Rim/fisiopatologia , Lipocalina-2/urina , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
11.
Rev Esp Anestesiol Reanim ; 64(9): 533-536, 2017 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28390712

RESUMO

Intrathecal injection of fluorescein is a method for repairing cerebrospinal fluid fistulas. The most frequent surgical procedure is endonasal endoscopy and the purpose of injecting this dye is to locate the fistula. The anaesthesiologists usually perform the puncture, therefore it is necessary to review this method and to specify some anaesthetic considerations such as correct dosing, safe management protocols and medical-legal aspects. In this case-report we describe the pre, intra and postoperative protocol of action implemented in our department that basically consists of: obtaining a specific consent, prior neurological/ophthalmologic assessment to rule out hypertension and brain damage, use of corticosteroids and previous antihistamines, choosing the correct dose and concentration of intrathecal sodium fluorescein (maximum 1ml at a concentration of 5% diluted in 9ml of cerebrospinal fluid) and close intra and postoperative monitoring.


Assuntos
Rinorreia de Líquido Cefalorraquidiano/diagnóstico por imagem , Fluoresceína/administração & dosagem , Corantes Fluorescentes/administração & dosagem , Idoso , Algoritmos , Aracnoide-Máter/diagnóstico por imagem , Aracnoide-Máter/lesões , Rinorreia de Líquido Cefalorraquidiano/etiologia , Rinorreia de Líquido Cefalorraquidiano/cirurgia , Protocolos Clínicos , Traumatismos Craniocerebrais/complicações , Dura-Máter/diagnóstico por imagem , Dura-Máter/lesões , Endoscopia , Feminino , Fluoresceína/efeitos adversos , Fluoresceína/farmacocinética , Corantes Fluorescentes/efeitos adversos , Corantes Fluorescentes/farmacocinética , Cefaleia/induzido quimicamente , Humanos , Injeções Espinhais , Complicações Pós-Operatórias/induzido quimicamente , Solventes/efeitos adversos
12.
Obstet Gynecol ; 128(6): 1378-1383, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27824741

RESUMO

OBJECTIVE: To compare different modalities to aid in the evaluation of intraoperative ureteral patency on cystoscopy in the postindigo carmine era. METHODS: In a randomized controlled trial, participants undergoing pelvic surgery were randomized into one of four groups: saline distention (control), 10% dextrose distention, oral phenazopyridine, or intravenous sodium fluorescein. Our primary outcome was visibility of the ureteral jets. Secondary outcomes included surgeon satisfaction; adverse reactions including allergies, urinary tract infections, urinary retention, cystoscopy times, and ureteral obstruction; and delayed diagnosis. Participants were followed for 6 weeks. A sample size of 176 participants was planned to demonstrate a 30% difference in the visibility scale. All analyses were performed in an intention-to-treat fashion. RESULTS: From February 25, 2015, through August 2015, 176 participants were enrolled; 174 completed the trial, and two did not undergo intervention. Forty-four participants were included in the phenazopyridine, dextrose, saline, and sodium fluorescein groups. Sodium fluorescein and 10% dextrose resulted in significantly improved visibility and satisfaction when compared with the control group (P<.001 and P=.004, respectively). Dextrose provided the highest satisfaction and phenazopyridine provided lowest, but visibility was not statistically different between the two groups (P=.101). Three ureteral obstructions were identified intraoperatively and none in the postoperative period. Mean total cystoscopy time varied between 4.0 and 4.8 minutes and postoperative urinary retention rate was 50% across all groups. Overall urinary tract infection rate was 24.1%, which was similar between interventions. There were no related adverse events. CONCLUSION: Compared with the control, 10% dextrose and sodium fluorescein resulted in improved visibility and provided significantly more satisfaction in the evaluation for ureteral patency with no considerable increase in operative time or morbidity. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, https://clinicaltrials.gov, NCT02476448.


Assuntos
Cistoscopia , Procedimentos Cirúrgicos em Ginecologia/efeitos adversos , Complicações Intraoperatórias/diagnóstico , Ureter/lesões , Ferimentos e Lesões/diagnóstico , Administração Intravenosa , Administração Oral , Idoso , Atitude do Pessoal de Saúde , Cistoscopia/efeitos adversos , Cistoscopia/métodos , Feminino , Fluoresceína/administração & dosagem , Fluoresceína/efeitos adversos , Corantes Fluorescentes/administração & dosagem , Corantes Fluorescentes/efeitos adversos , Glucose/administração & dosagem , Glucose/efeitos adversos , Humanos , Cuidados Intraoperatórios , Complicações Intraoperatórias/etiologia , Pessoa de Meia-Idade , Duração da Cirurgia , Fenazopiridina/administração & dosagem , Fenazopiridina/efeitos adversos , Estudos Prospectivos , Obstrução Ureteral/etiologia , Retenção Urinária/etiologia , Infecções Urinárias/etiologia , Ferimentos e Lesões/etiologia
13.
Gastrointest Endosc ; 84(6): 917-923.e5, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27189657

RESUMO

BACKGROUND AND AIMS: Image quality can be guaranteed with the conventional dosage of fluorescein sodium in probe-based confocal laser endomicroscopy (pCLE). However, yellow discoloration of the skin seriously affects daily life and simultaneously increases the risk of adverse events such as allergic reactions. The aim of this study was to test whether a lower dosage of fluorescein sodium can provide satisfactory image quality and to compare the diagnostic accuracy of gastric intestinal metaplasia (GIM) through a randomized blind controlled trial. METHODS: Consecutive patients were randomly assigned to different doses of fluorescein sodium. Image quality was determined by the endoscopists' subjective assessments and signal-to-noise ratio (SNR) assessment systems. Skin discoloration was tested using a neonatal transcutaneous jaundice detector. In addition, consecutive patients with a known or suspected diagnosis of GIM were examined by pCLE with the lower dose and the traditional dose. RESULTS: Only 0.01 mL/kg dose of 10% fluorescein sodium led to a significant decrease in image quality (P < .05), and a dose of 0.02 mL/kg had the highest SNR value (P < .05). There were no significant differences in skin discoloration between the 0.01 mL/kg and 0.02 mL/kg doses (P = .148) and no statistical difference in the diagnostic accuracy of pCLE for GIM between the 0.02 mL/kg and 0.10 mL/kg doses (P > .05). The kappa values for the correlation between pCLE and histopathology were 0.867 (95% confidence interval, 0.782-0.952) and 0.891 (95% confidence interval, 0.811-0.971). CONCLUSIONS: The 0.02 mL/kg dose of 10% fluorescein sodium seems to be the best dose for pCLE in the upper GI tract, with comparable image quality with the conventional dose and insignificant skin discoloration. This dose is also very efficient for the diagnosis of GIM.


Assuntos
Meios de Contraste/administração & dosagem , Fluoresceína/administração & dosagem , Trato Gastrointestinal/patologia , Microscopia Intravital/métodos , Adulto , Idoso , Meios de Contraste/efeitos adversos , Endoscopia Gastrointestinal , Estudos de Viabilidade , Feminino , Fluoresceína/efeitos adversos , Humanos , Microscopia Intravital/normas , Masculino , Metaplasia/diagnóstico por imagem , Microscopia Confocal/métodos , Microscopia Confocal/normas , Pessoa de Meia-Idade , Transtornos da Pigmentação/induzido quimicamente , Razão Sinal-Ruído , Método Simples-Cego , Pigmentação da Pele/efeitos dos fármacos , Adulto Jovem
14.
Clin Neurol Neurosurg ; 146: 123-9, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27208872

RESUMO

OBJECTIVE: The objective of this study is to assess the feasibility of simultaneous Sodium Fluorescein (SF) and Indocyanine Green (ICG) injection during neurosurgical procedures. PATIENTS AND METHODS: Three patients harboring a high-grade glioma (HGG) were retrospectively identified in the surgical database of the Neurosurgical Unit 2 at the Foundation IRCCS Istituto Neurologico C. Besta in Milan, by having received intraoperatively both SF for tumor resection and ICG for vasculature angiographic studies in the same surgical procedure. We identified 2 males and 1 female (age range 25-60). Lesions were located in the left temporo-polar area and hippocampus (1 case), right superior frontal gyrus (1 case), left supplementary motor area (1 case). All the three lesions showed Magnetic Resonance Imaging (MRI) characteristics of HGG and, for this reason, in all patients a fluorescein-guided tumor removal was proposed. In the same surgical procedure ICG videoangiography was considered necessary in order to study arterial and venous vasculature, given by the strict relation of the tumor with an unexpected Posterior Communicating Artery (PComA) aneurysm in one case and with cortical drainage veins complexes in the other two cases. In all cases a microscope equipped with both YELLOW560 and IR800 integrated filters (Pentero 900, Carl Zeiss, Oberkorchen, Germany) was used. Fluorescein was i.v. injected at a dose of 5mg/kg immediately after patient intubation. ICG was i.v. injected in bolus on demand of the operating surgeon at a dose of 12.5mg. RESULTS: No side-effects related to simultaneous injection of SF and ICG were identified. In all three cases, the use of SF allowed to better visualize the tumor areas during surgical removal, thus leading to a radical resection until no macroscopic appearance of residual tumor mass and no fluorescence was visible in the surgical cavity. ICG videoangiography confirmed the patency of branches of internal carotid artery after clipping of an unexpected small PComA aneurysm found intraoperatively during tumor removal in one case, while in patient 2 and 3 it allowed to evaluate patency and study flow pattern in cortical drainage veins that were intimately related to the tumors and the way of the surgical approach. Postoperative MRI showed a Gross Total Resection of the tumors in all cases. CONCLUSIONS: This study showed for the first time the feasibility of intravenous SF injection and ICG videoangiography in the same surgical procedure. The presence of different fluorescence filters on the same surgical microscope allows the surgeon to recognize and safely resect the tumor and simultaneously evaluate local brain vascularization.


Assuntos
Corantes/administração & dosagem , Fluoresceína/administração & dosagem , Verde de Indocianina/administração & dosagem , Procedimentos Neurocirúrgicos/métodos , Adulto , Corantes/efeitos adversos , Estudos de Viabilidade , Feminino , Fluoresceína/efeitos adversos , Humanos , Verde de Indocianina/efeitos adversos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
15.
Acta Neurochir (Wien) ; 157(6): 899-904, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25824557

RESUMO

BACKGROUND: Surgical resection is a key element of the multidisciplinary treatment of cerebral metastases (CMs). Recent studies have highlighted the importance of complete resection of CMs for improving recurrence-free and overall survival rates. This study presents the first data on the use of fluorescein sodium (FL) under the dedicated surgical microscope filter YELLOW 560 nm (Zeiss Meditec, Germany) in patients with CM. METHODS: Thirty patients with CMs of different primary cancers were included (15 females, 15 males; mean age 61.1 years); 200 mg of FL was intravenously injected directly before CM resection. A YELLOW 560 nm filter was used for microsurgical tumor resection and resection control. Surgical reports were evaluated regarding the degree of fluorescent staining, postoperative MRIs regarding the extent of resection [gadolinium (Gd)-enhanced T1-weighted sequence] and the postoperative courses regarding any adverse effects. RESULTS: Most patients (90.0%, n = 27) showed bright fluorescent staining, which markedly enhanced tumor visibility. Three patients (10.0%) (two with adenocarcinoma of the lung and one with melanoma of the skin) showed no or only insufficient FL staining. Another three patients (10.0%) showed residual tumor tissue in the postoperative MRI examination. In two other patients, radiographic examination could not exclude the possibility of very small areas of residual tumor tissue. Thus, gross-total resection was achieved in 83.3% (n = 25) of patients. No adverse effects were registered over the postoperative course. CONCLUSIONS: FL and the YELLOW 560 nm filter are safe and practical tools for the resection of CM, but further prospective research is needed to confirm that this advanced technique will improve the quality of CM resection.


Assuntos
Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/cirurgia , Meios de Contraste , Fluoresceína , Procedimentos Neurocirúrgicos/métodos , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/efeitos adversos , Feminino , Fluoresceína/efeitos adversos , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Neoplasia Residual/patologia , Procedimentos Neurocirúrgicos/efeitos adversos , Neoplasias Supratentoriais/cirurgia , Cirurgia Assistida por Computador/efeitos adversos , Resultado do Tratamento
16.
Arch Iran Med ; 16(5): 264-6, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23641738

RESUMO

BACKGROUND: Intrathecal injection of fluorescein is a useful adjuvant method for localization of fistulas in endoscopic endonasal repair of cerebrospinal fluid (CSF) leakage. Although being neurotoxic in commercial doses, a low dose of diluted fluorescein seems to be safe on the basis the existing data in the literature. OBJECTIVES: The purpose of this study was to investigate the role of a low- dose intrathecal fluorescein injection in detection of CSF fistula and potential adverse effects of this technique. MATERIALS AND METHODS: CSF rhinorrhea was repaired in 20 patients with an endoscopic endonasal technique. Intraoperative intrathecal fluorescein injection was used for localization of the site of the CSF leak. The accuracy rate of leakage site identification and the incidence of complications and recurrences were recorded. RESULTS: Intrathecal administration of fluorescein demonstrated CSF leakage in 18 of the 20 patients (90%). There were no intraoperative complications. Definitive closure of the CSF leakage site was achieved in 16 patients (80%) after the initial reconstruction. Recurrence occurred in four cases and all patients were free of CSF leakage after the second surgical attempt. CONCLUSIONS: The present study suggested that a low dose of intraoperative intrathecal fluorescein administration is a safe and sensitive method for localization of CSF leakage sites.


Assuntos
Rinorreia de Líquido Cefalorraquidiano/etiologia , Endoscopia/métodos , Fístula/complicações , Fluoresceína/administração & dosagem , Adolescente , Adulto , Idoso , Rinorreia de Líquido Cefalorraquidiano/cirurgia , Criança , Endoscopia/efeitos adversos , Feminino , Fístula/cirurgia , Fluoresceína/efeitos adversos , Humanos , Injeções Espinhais/efeitos adversos , Injeções Espinhais/métodos , Masculino , Pessoa de Meia-Idade , Procedimentos de Cirurgia Plástica/métodos , Recidiva , Resultado do Tratamento
17.
Retina ; 33(8): 1574-83, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23584697

RESUMO

PURPOSE: To evaluate the safety of oral fluorescein angiography (FA) and to compare its efficacy in detection of macular edema (ME) with spectral-domain optical coherence tomography (SD-OCT). METHODS: Results of imaging studies for 1,928 eyes of 1,019 patients who had simultaneously undergone both oral FA and SD-OCT by a confocal laser ophthalmoscope were reviewed. Sensitivity in detecting ME, discrepancy rate, and "kappa" agreement were determined for both the techniques and with eyes stratified by disease diagnosis. RESULTS: No allergic reactions occurred after oral FA. Mild gastric discomfort was noted in <1% of the patients; 1,840 eyes (95.4%) showed concordance between the two techniques, and kappa agreement was 90.3%. For ME, oral FA showed an overall sensitivity of 0.97 and SD-OCT of 0.91. Equivalent sensitivity was found in cases of wet age-related macular degeneration (0.99). Oral FA was more sensitive than SD-OCT in cases of retinovascular diseases. The SD-OCT showed higher sensitivity in cases of macular holes. Detection of ME by SD-OCT was significantly higher in cases of intense leakage on oral FA (P < 0.001). CONCLUSION: Oral FA proved to be a safe and an adequate technique to evaluate ME. It is more sensitive than SD-OCT in detection of ME in cases of retinovascular diseases but can fail to detect ME in cases of macular holes. A noninvasive examination with simultaneous oral FA and SD-OCT may be considered to obtain a comprehensive evaluation of the presence of ME from different pathologies.


Assuntos
Angiofluoresceinografia/métodos , Fluoresceína , Corantes Fluorescentes , Edema Macular/diagnóstico , Tomografia de Coerência Óptica/métodos , Administração Oral , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Fluoresceína/administração & dosagem , Fluoresceína/efeitos adversos , Corantes Fluorescentes/administração & dosagem , Corantes Fluorescentes/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Oftalmoscopia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento , Acuidade Visual/fisiologia , Adulto Jovem
18.
Anaesthesist ; 60(8): 740-2, 2011 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-21728050

RESUMO

This case history deals with an 85-year-old patient who underwent surgery to treat rhinoliquorrhea. The patient aspirated a lutescent fluid shortly after anesthesia was administered. However, this fluid was not gastric juice but cerebrospinal fluid (CSF) running down the nasopharynx. The CSF had been stained with fluorescein prior to surgery in order to help localize the CSF fistula. This case of top down aspiration is discussed and preventive measures which can be employed in order to avoid similar complications in patients with rhinoliquorrhea are presented.


Assuntos
Rinorreia de Líquido Cefalorraquidiano/cirurgia , Meios de Contraste/efeitos adversos , Fluoresceína/efeitos adversos , Idoso de 80 Anos ou mais , Anestesia , Humanos , Refluxo Laringofaríngeo , Masculino , Monitorização Intraoperatória , Nasofaringe/fisiologia , Complicações Pós-Operatórias/etiologia
19.
J Cataract Refract Surg ; 37(5): 907-13, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21420274

RESUMO

PURPOSE: To assess the effect of a combination of proparacaine 0.50%-sodium fluorescein 0.25% and ultrasound (US) pachymetry on central and midperipheral corneal thickness. SETTING: School of Optometry and Vision Sciences, Cardiff University, Cardiff, Wales, United Kingdom. DESIGN: Case series. METHOD: Topographic measurements of corneal thickness in healthy right eyes were obtained using a scanning-slit device (Orbscan IIz) and a Scheimpflug device (Pentacam) before and after application of proparacaine 0.50%-sodium fluorescein 0.25% and US pachymetry. Changes in corneal thickness in the center and 2.5 mm from the center in the temporal, nasal, inferior, and superior locations were assessed. RESULTS: The study evaluated 35 eyes. The scanning-slit and Scheimpflug devices recorded a small but statistically significant increase in corneal thickness at all locations (mean 4.9 ± 14.3 [SD] to 9.1 ± 11.7 µm; P<.05, paired t test). The cornea swelled uniformly across its diameter (scanning slit, P=.934; Scheimpflug, P=.654; analysis of variance); there was no statistically significant difference in the amount of swelling between the 2 devices (P>.05, t test). The 95% limits of agreement were broad (-10 to +30 µm), suggesting a large degree of interindividual variability. CONCLUSIONS: Ultrasound pachymetry combined with proparacaine 0.50%-sodium fluorescein 0.25% caused a small (<10 µm) but significant amount of corneal swelling on average. Because the effect on corneal thickness may be greater than -10 to +30 µm in individual cases, clinicians should avoid contact procedures before obtaining topographic maps of corneal thickness using scanning-slit and Scheimpflug devices.


Assuntos
Anestésicos Locais/efeitos adversos , Córnea/efeitos dos fármacos , Edema da Córnea/induzido quimicamente , Técnicas de Diagnóstico Oftalmológico/instrumentação , Fluoresceína/efeitos adversos , Corantes Fluorescentes/efeitos adversos , Propoxicaína/efeitos adversos , Adulto , Córnea/diagnóstico por imagem , Edema da Córnea/diagnóstico por imagem , Topografia da Córnea , Combinação de Medicamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Refração Ocular/fisiologia , Ultrassonografia , Acuidade Visual/fisiologia , Adulto Jovem
20.
J Clin Neurosci ; 18(3): 430-1, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21237654

RESUMO

We present a male patient who underwent a fluorescein sodium-guided brain tumor excision and experienced an anaphylactic reaction with severe hypotension and bradycardia. A 54-year-old, 70 kg man of American Society of Anesthesiologists status II was seen with a history of glioma. In the 80th minute of the operation, 20 mg/kg intravenous (i.v.) fluorescein sodium was injected after dural opening. A few minutes later, the anaphylactic reaction was diagnosed. Surgery was ended and the patient was delivered to the intensive care unit with intubation. Laboratory values were: immunoglobulin E, 332 U (upper limit 100 U); and elevated tryptase, 3.12 mg/dL. In view of the expanding use of fluorescein sodium in clinical procedures, physicians should be alerted to this rare but life-threatening adverse event.


Assuntos
Anafilaxia/induzido quimicamente , Fluoresceína/efeitos adversos , Corantes Fluorescentes/efeitos adversos , Neoplasias Encefálicas/cirurgia , Glioma/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA