Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 715
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Immunol Methods ; 531: 113710, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38871279

RESUMO

When the membrane protein CD40 ligand (CD40L) on activated T cells binds the receptor CD40 on B-cells, it provides a co-stimulatory signal for B cell activation. Dysregulation of the CD40L:CD40 axis is associated with inflammatory and autoimmune diseases. The presence of soluble CD40L (sCD40L) in plasma is implicated in several diseases, from cardiovascular and autoimmune diseases to different types of cancer, and sCD40L has been suggested as a valuable marker of disease. If sCD40L is to be used as a biomarker, being able to precisely measure and quantify the levels of sCD40L in human blood samples is of utmost importance. We demonstrate the development of a sandwich-type time-resolved immunofluorometric assay for quantification of sCD40L in plasma or serum samples. For this, we generate 29 monoclonal anti-CD40L antibodies, and from these, we select the optimal combination of capture antibody and detection antibody. A number of variables were tested: the influence of the type of sample (comparing 3 different blood collection tubes for serum sampling and 4 different types of tubes for plasma sampling), the influence of freeze-thaw cycles, the influence of sampling time during night and day, and the influence of centrifugation of the samples. We found a very similar level of sCD40L in paired EDTA plasma and serum samples. Out of 100 healthy blood donor samples 61 had a level of sCD40L below the detection level of the assay, whereas the remaining 39 samples had ranging levels of sCD40L from 1.14 to 33.14 ng/mL. In summary, we present a time-resolved immunofluorometric assay based on paired monoclonal antibodies, ensuring high specificity, sensitivity, and homogeneity. The Eu3+-based assay additionally provides consistent assay readouts due to the extended decay time not seen in standard enzyme-linked immunosorbent assays. The assay paves the way for specific and consistent quantification of sCD40L in human plasma and serum samples.


Assuntos
Ligante de CD40 , Humanos , Ligante de CD40/sangue , Biomarcadores/sangue , Anticorpos Monoclonais/imunologia , Fluorimunoensaio/métodos , Reprodutibilidade dos Testes
2.
Luminescence ; 39(5): e4747, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38716575

RESUMO

Atezolizumab (ATZ) is a human monoclonal antibody, which has been granted multiple approvals from the US Food and Drug Administration (FDA) for the immunotherapy of different types of cancer. This study describes the prototype of a time-resolved fluoroimmunoassay (TRFIA) for the quantitation of ATZ in plasma. The assay involved the non-competitive binding of ATZ to its specific antigen [programmed death-ligand 1 (PD-L1) protein]. The immune complex formed on the inner surface of the assay plate wells was quantified by anti-human secondary antibody labeled with a chelate of europium-ethylenediaminetetraacetic acid. The enhanced fluorescence signal was generated by an enhanced fluorescence solution composed of thenoyltrifluoroacetone, trioctylphosphine oxide, and Triton X-100. The conditions of the TRFIA were refined, and its optimum procedures were established. The assay was validated in accordance with the immunoassay validation guidelines, and all the validation parameters were acceptable. The working range of the assay was 20-1000 pg mL-1, and its limit of quantitation was 20 pg mL-1. The assay was applied to the quantitation of ATZ in plasma samples with satisfactory accuracy and precision. The proposed TRFIA has significant benefits over the existing methodologies for the quantitation of ATZ in clinical settings.


Assuntos
Anticorpos Monoclonais Humanizados , Fluorimunoensaio , Fluorimunoensaio/métodos , Humanos , Anticorpos Monoclonais Humanizados/sangue , Anticorpos Monoclonais Humanizados/química , Anticorpos Monoclonais Humanizados/imunologia , Fluorescência , Fatores de Tempo
3.
Anal Methods ; 15(35): 4541-4547, 2023 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-37642087

RESUMO

Immunoassays are commonly used in disease diagnosis and vaccine evaluation but can be costly and time-consuming when confronted with multivalent targets, such as antisera containing antibodies to human papillomavirus (HPV), because of their limited ability to discriminate between multiple analytes in a single reaction well. This study describes the development of a high-throughput liquid chip system that combines immunoassay techniques and magnetic beads to allow the simultaneous screening and quantitative detection of antibodies to four types of HPV using the Luminex fluoroimmunoassay system. Groups of beads embedded with fluorescent dyes at various ratios were coated with optimized HPV capture antigens and demonstrated excellent dose-dependent response to four monoclonal antibodies used as reference standards. This assay is sensitive, accurate, repeatable, and simple to perform, enabling multiplex antibody detection with a high degree of orthogonality. The performance of the Luminex system was compared with conventional immunoassays for quantitative detection of quadrivalent HPV antibodies in antisera of mice immunized with five lots of HPV vaccines, verifying the accuracy and detection efficiency of the assay. This strategy is a promising approach to characterizing antibodies present in polyclonal antisera and has promising applications in research, clinical, and industrial settings, for example, streamlining vaccine efficacy trials and vaccine lot inspection and release procedures.


Assuntos
Papillomavirus Humano , Infecções por Papillomavirus , Humanos , Animais , Camundongos , Infecções por Papillomavirus/diagnóstico , Anticorpos Antivirais , Fluorimunoensaio , Soros Imunes , Antígenos Virais
4.
Anal Biochem ; 666: 115072, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36738873

RESUMO

AIM: To develop a highly sensitive time-resolved fluorescence immunoassay (TRFIA) for the detection of serum matrix metalloproteinase-3 (MMP-3) and to assess MMP-3's clinical value in patients with colorectal cancer (CRC).st. METHODS: MMP-3 levels were established using the double antibody sandwich technique. The MMP-3 TRFIA technique was developed and optimized, and its linearity, sensitivity, accuracy, specificity, and recovery were assessed. Then, serum concentrations in healthy individuals and patients with CRC were determined by MMP-3 TRFIA. RESULTS: The linear range of MMP-3 TRFIA was 0.73-500 ng/mL. MMP-3 TRFIA had an intra-batch precision range of 2.16%-7.10% percent and an inter-batch precision range of 3.99%-11.21%. MMP-3, tumor-associated trypsinogen 2, and AFP had no cross reaction.The recovery is between 90% and 110%, and had no serum interference. Patients with CRC had serum MMP-3 levels (73.95 ± 78.43 ng/mL) that were considerably higher than those of healthy individuals (21.45 ± 11.12 ng/mL), and those with metastasis had serum MMP-3 levels (95.89 ± 76.21 ng/mL) that were considerably higher than those of patients without metastasis (52.74 ± 47.25 ng/mL). CONCLUSIONS: A highly sensitive MMP-3 TRFIA assay was successfully developed, and serum MMP-3 may be associated with CRC invasion and metastasis. Therefore, MMP-3 can be used in the auxiliary diagnosis of CRC.


Assuntos
Fluorimunoensaio , Metaloproteinase 3 da Matriz , Humanos , Fluorimunoensaio/métodos , Soro , Anticorpos
5.
BMC Biotechnol ; 22(1): 27, 2022 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-36180909

RESUMO

BACKGROUND: Lymphocytic leukemia (LL) is a primary malignant tumor of hematopoietic tissue, which seriously affects the health of children and the elderly. The study aims to establish a new detection method for screening acute/chronic LL using time-resolved fluorescence immunoassay (TRFIA) via quantitative detection of S100 calcium binding protein A8 (S100A8) and leucine-rich alpha-2-glycoprotein 1 (LRG1) in serum. METHODS: Here a sandwich TRFIA was optimized and established: Anti-S100A8/LRG1 caputre antibodies immobilized on 96-well plates captured S100A8/LRG1, and then banded together with the anti-S100A8/LRG1 detection antibodies labeled with Europium(III) (Eu3+)/samarium(III) (Sm3+) chelates. Finally time resolved fluorometry measured the fluorescence intensity. RESULTS: The sensitivity of S100A8 was 1.15 ng/mL(LogY = 3.4027 + 0.4091 × LogX, R2 = 0.9828, P < 0.001, dynamic range: 2.1-10,000 ng/mL), and 3.2 ng/mL for LRG1 (LogY = 3.3009 + 0.4082 × LogX, R2 = 0.9748, P < 0.001, dynamic range: 4.0-10,000 ng/mL). The intra-assay and inter-assay CVs were low, ranging from 5.75% to 8.23% for S100A8 and 5.30% to 9.45% for LRG1 with high specificity and affinity in serum samples. Bland-Altman plots indicated TRFIA and ELISA kits have good agreement in clinical serum samples. Additionally, the cutoff values for S100A8 and LRG1 were 1849.18 ng/mL and 588.08 ng/mL, respectively. CONCLUSION: The present TRFIA method could be used for the quantitative detection of S100A8 and LRG1 in serum, and it has high sensitivity, accuracy and specificity. Clinically, this TRFIA method could be suitable for screening of LL via the quantitative detection of S100A8 and LRG1.


Assuntos
Európio , Leucemia Linfocítica Crônica de Células B , Idoso , Proteínas de Ligação ao Cálcio , Criança , Fluorimunoensaio/métodos , Glicoproteínas , Humanos , Leucina , Leucemia Linfocítica Crônica de Células B/diagnóstico , Samário , Sensibilidade e Especificidade
6.
Anal Bioanal Chem ; 414(24): 7143-7151, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36006431

RESUMO

In recent years, more and more functional peptide ligands have been identified from phage display libraries and served the immunoassay of small molecules. After the identification, the phage particle instead limits further application of peptide ligands, so it is of great significance to explore the peptide ligand as an independent detection reagent. In this work, the identified peptidomimetic of benzothiostrobin was synthesized and labelled with biotin, which was combined with Eu3+-labelled streptavidin to develop the peptide-based time-resolved fluoroimmunoassay (P-TRFIA). Under the optimal conditions, the half-maximum inhibitory concentration (IC50) of proposed P-TRFIA is 3.63 ng mL-1, which is similar to the TRFIA using phage-borne peptidomimetic and Eu3+-labelled anti-phage antibody (IC50: 4.55 ng mL-1), also more sensitive than previously reported immunoassays for benzothiostrobin. In addition, the proposed P-TRFIA shows excellent specificity and accuracy for analysis of spiked samples, and its detection results shows good consistency with high-performance liquid chromatography for the detection of environment and agro-products samples with unknown benzothiostrobin concentrations.


Assuntos
Biotina , Peptidomiméticos , Acrilatos , Benzotiazóis , Fluorimunoensaio/métodos , Ligantes , Peptídeos/química , Sensibilidade e Especificidade , Estreptavidina
7.
J Fluoresc ; 32(4): 1501-1507, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35511384

RESUMO

To establish a rapid and highly sensitive assay for tumor-associated trypsinogen-2 (TAT-2) based on the time-resolved fluorescence immunoassay (TRFIA) and evaluate its potential clinical value in patients with lung cancer. The double-antibody sandwich method was used in detecting TAT-2 antigen concentrations, and two types of TAT-2 antibodies (coating antibodies and Eu3+ labeled antibodies) were used. A TAT-2-TRFIA method was then established, evaluated, and used in detecting the serum TAT-2 levels of healthy subjects and patients with lung cancer. The linear range of the TAT-2-TRFIA method was 1.53-300 ng/mL, the intra-assay coefficient of variation (CV) were between 1.67% and 8.42%, and the inter-assay CV were between 4.29% and 11.44%. The recovery rates of TAT-2-TRFIA were between 99.17% and 107.06%. The cross-reactivities of trypsin and T-cell immunoglobulin mucin 3 were 0.02% and 0.82%, respectively. The serum TAT-2 levels of patients with lung cancer were higher than those of healthy subjects (P < 0.001). Combined with TAT-2, the sensitivity and specificity of CEA and CA-125 for lung cancer improved significantly. Conclusion: We successfully established a highly sensitive TAT-2-TRFIA method, which was able to facilitate the timely diagnosis of lung cancer.


Assuntos
Neoplasias Pulmonares , Tripsinogênio , Fluorimunoensaio/métodos , Humanos , Neoplasias Pulmonares/diagnóstico , Sensibilidade e Especificidade , Tripsina
8.
Anal Biochem ; 648: 114674, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35351395

RESUMO

AIM: This study aimed to establish a highly sensitive time-resolved fluorescence immunoassay (TRFIA) for the detection of serum lipoprotein-associated phospholipase A2 (Lp-PLA2) and evaluate the clinical application value of Lp-PLA2 in patients with breast cancer. METHODS: The level of Lp-PLA2 was detected using the double-antibody sandwich method. First, the Lp-PLA2-TRFIA method was established, and the method was evaluated on the basis of linearity, sensitivity, precision, specificity, and recovery rate. Then, the fluorescence counts in serum of healthy subjects and patients with breast cancer were detected by Lp-PLA2-TRFIA, and the levels of Lp-PLA2 were calculated using a standard curve. RESULTS: Lp-PLA2-TRFIA had a wide linear range (43.48-2000 ng/mL). The intra-assay precisions of Lp-PLA2-TRFIA ranged from 2.66% to 4.84% (<10%), and the inter-assay precisions were between 5.39% and 6.95% (<15%). No cross-reaction was observed among Lp-PLA2, Tumor-associated trypsinogen-2, and T-cell immunoglobulin mucin 3. In addition, the recovery rates were between 90% and 100%. The serum Lp-PLA2 levels of patients with breast cancer were significantly higher than those of healthy subjects. CONCLUSIONS: We successfully established a highly sensitive Lp-PLA2-TRFIA method, and found serum Lp-PLA2 may be associated with dyslipidemia in breast cancer and could be used for auxiliary diagnose.


Assuntos
1-Alquil-2-acetilglicerofosfocolina Esterase , Neoplasias da Mama , Biomarcadores , Neoplasias da Mama/diagnóstico , Feminino , Fluorimunoensaio , Humanos
9.
Sci Rep ; 12(1): 105, 2022 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-34996935

RESUMO

Soluble immune checkpoint molecules are emerging novel mediators of immune regulation. However, it is unclear whether soluble immune checkpoint proteins affect the development of hepatocellular carcinoma (HCC) during nucleos(t)ide analogue (NA) treatment in patients with chronic hepatitis B virus infection. This study included 122 NA-naïve patients who received NA therapy. We assessed the associations of clinical factors, including soluble immune checkpoint proteins, with HCC development during NA treatment. The baseline serum concentrations of 16 soluble immune checkpoint proteins were measured using multiplexed fluorescent bead-based immunoassay. In total, 13 patients developed HCC during the follow-up period (median duration, 4.3 years). Of the 16 proteins, soluble inducible T-cell co-stimulator (≥ 164.71 pg/mL; p = 0.014), soluble programmed cell death-1 (sPD-1) (≤ 447.27 pg/mL; p = 0.031), soluble CD40 (≤ 493.68 pg/mL; p = 0.032), and soluble herpes virus entry mediator (≤ 2470.83 pg/mL; p = 0.038) were significantly associated with HCC development (log-rank test). In multivariate analysis, an sPD-1 level ≤ 447.27 pg/mL (p = 0.014; hazard ratio [HR], 4.537) and α-fetoprotein level ≥ 6.4 ng/mL (p = 0.040; HR, 5.524) were independently and significantly associated with HCC development. Pre-treatment sPD-1 is a novel predictive biomarker for HCC development during NA treatment.


Assuntos
Antivirais/uso terapêutico , Carcinoma Hepatocelular/prevenção & controle , Guanina/análogos & derivados , Hepatite B Crônica/tratamento farmacológico , Neoplasias Hepáticas/prevenção & controle , Nucleosídeos/uso terapêutico , Receptor de Morte Celular Programada 1/sangue , Adulto , Idoso , Biomarcadores/sangue , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/virologia , Feminino , Fluorimunoensaio , Guanina/efeitos adversos , Guanina/uso terapêutico , Hepatite B Crônica/sangue , Hepatite B Crônica/diagnóstico , Hepatite B Crônica/virologia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/virologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
10.
BMC Nephrol ; 23(1): 30, 2022 01 14.
Artigo em Inglês | MEDLINE | ID: mdl-35031018

RESUMO

BACKGROUND: AKI is related to severe adverse outcomes and mortality with Coronavirus Disease 2019 (COVID-19) patients, that early diagnosed and intervened is imperative. Neutrophil gelatinase-associated lipocalin (NGAL) is one of the most promising biomarkers for detection of acute kidney injury (AKI), but current detection methods are inadequacy, so more rapid, convenient and accuracy methods are needed to detect NGAL for early diagnosis of AKI. Herein, we established a rapid, reliable and accuracy lateral flow immunoassay (LFIA) based on europium nanoparticles (EU-NPS) for the detection of NGAL in human urine specimens. METHODS: A double-antibody sandwich immunofluorescent assay using europium doped nanoparticles was employed and the NGAL monoclonal antibodies (MAbs) conjugate as labels were generated by optimizing electric fusion parameters. Eighty-three urine samples were used to evaluate the clinical application efficiency of this method. RESULTS: The quantitative detection range of NGAL in AKI was 1-3000 ng/mL, and the detection sensitization was 0.36 ng/mL. The coefficient of variation (CV) of intra-assay and inter-assay were 2.57-4.98 % and 4.11-7.83 %, respectively. Meanwhile, the correlation coefficient between europium nanoparticles-based lateral fluorescence immunoassays (EU-NPS-LFIA) and ARCHITECT analyzer was significant (R2 = 0.9829, n = 83, p < 0.01). CONCLUSIONS: Thus, a faster and easier operation quantitative assay of NGAL for AKI has been established, which is very important and meaningful to diagnose the early AKI, suggesting that the assay can provide an early warning of final outcome of disease.


Assuntos
Injúria Renal Aguda/diagnóstico , Európio , Fluorimunoensaio/métodos , Lipocalina-2/urina , Nanopartículas Metálicas , Injúria Renal Aguda/virologia , Animais , Anticorpos Monoclonais/isolamento & purificação , COVID-19/complicações , Ensaio de Imunoadsorção Enzimática , Humanos , Lipocalina-2/imunologia , Camundongos , Proteínas Recombinantes/isolamento & purificação , Reprodutibilidade dos Testes , SARS-CoV-2
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA