Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 11.286
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Urol ; 211(6): 735-742, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38721932

RESUMO

PURPOSE: Fluoroscopy is usually required during retrograde intrarenal surgery (RIRS). Although fluoroscopy is considered necessary for effective and safe RIRS, there is growing awareness regarding radiation exposure risk to patients and surgeons. We conducted a multicenter-based, randomized, controlled trial to compare the safety and effectiveness of radiation-free (RF) RIRS with radiation-usage (RU) RIRS for kidney stone management. MATERIALS AND METHODS: From August 2020 to April 2022, patients with a unilateral kidney stone (≤20 mm) eligible for RIRS were prospectively enrolled in 5 tertiary medical centers after randomization and divided into the RF and RU groups. RIRS was performed using a flexible ureteroscope with a holmium:YAG laser. The primary end point of this study was the success rate, defined as complete stone-free or residual fragments with asymptomatic kidney stones ≤ 3 mm. The secondary end point of this study was ascertaining the safety of RF RIRS. The success rates were analyzed using a noninferiority test. RESULTS: Of the 140 consecutive randomized participants, 128 patients completed this study (RF: 63; RU: 65). The success rates (78% vs 80%, P = .8) were not significantly different between the groups. The rate of high-grade (grade 2-4) ureter injury was not significantly higher in the RF group compared to the RU group (RF = 3 [4.8%] vs RU = 2 [3.1%], P = .6). In RF RIRS, the success rate was noninferior compared to RU RIRS (the difference was 2.2% [95% CI, 0.16-0.12]). CONCLUSIONS: This study demonstrated that the surgical outcomes of RF RIRS were noninferior to RU RIRS.


Assuntos
Cálculos Renais , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Cálculos Renais/cirurgia , Resultado do Tratamento , Fluoroscopia , Idoso , Adulto , Ureteroscopia/métodos , Ureteroscopia/efeitos adversos , Lasers de Estado Sólido/uso terapêutico , Exposição à Radiação/prevenção & controle , Rim/cirurgia
3.
Ital J Pediatr ; 50(1): 100, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760836

RESUMO

BACKGROUND: The European-funded Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy in Pediatrics (HARMONIC) project aims to improve knowledge on the effects of medical exposure to ionizing radiation (IR) received during childhood. One of its objectives is to build a consolidated European cohort of pediatric patients who have undergone cardiac catheterization (Cath) procedures, with the goal of enhancing the assessment of long-term radiation-associated cancer risk. The purpose of our study is to provide a detailed description of the Italian cohort contributing to the HARMONIC project, including an analysis of cumulative IR exposure, reduction trend over the years and an overview of the prospective collection of biological samples for research in this vulnerable population. METHODS: In a single-center retrospective cohort study, a total of 584 patients (323 males) with a median age of 6 (2-13) years, referred at the Pediatric Cardiology in Niguarda Hospital from January 2015 to October 2023, were included. Biological specimens from a subset of 60 patients were prospectively collected for biobanking at baseline, immediately post-procedure and after 12 months. RESULTS: Two hundred fifty-nine (44%) patients were under 1 year old at their first procedure. The median KAP/weight was 0.09 Gy·cm2/kg (IQR: 0.03-0.20), and the median fluoroscopy time was 8.10 min (IQR: 4.00-16.25). KAP/weight ratio showed a positive correlation with the fluoroscopy time (Spearman's rho = 0.679, p < 0.001). Significant dose reduction was observed either after implementation of an upgraded technology system and a radiation training among staff. The Italian cohort includes 1858 different types of specimens for Harmonic biobank, including blood, plasma, serum, clot, cell pellet/lymphocytes, saliva. CONCLUSIONS: In the Italian Harmonic cohort, radiation dose in cardiac catheterization varies by age and procedure type. An institution's radiological protection strategy has contributed to a reduction in radiation dose over time. Biological samples provide a valuable resource for future research, offering an opportunity to identify potential early biomarkers for health surveillance and personalized risk assessment.


Assuntos
Cateterismo Cardíaco , Cardiopatias Congênitas , Exposição à Radiação , Humanos , Itália , Masculino , Criança , Feminino , Pré-Escolar , Adolescente , Estudos Retrospectivos , Exposição à Radiação/efeitos adversos , Fluoroscopia/efeitos adversos , Doses de Radiação , Estudos de Coortes
4.
Urolithiasis ; 52(1): 75, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38753168

RESUMO

This study was designed to evaluate the non-inferiority of ultrasound puncture followed by endoscopically guided tract dilatation compared to the standard fluoroscopy-guided PCNL. Forty patients with non-opaque kidney stones eligible for PCNL were randomly divided into two groups. The standard fluoroscopy-guided PCNL using the Amplatz dilator was performed in the XRAY group. In the SONO group, the Kidney was punctured under an ultrasound guide followed by tract dilatation using a combination of the Amplatz dilator based on the tract length and an endoscopically guided tract dilatation using a bi-prong forceps in cases of short-advancement. The primary outcome was successful access. In 90% of cases in the XRAY and 95% in the SONO group access dilatation process was performed uneventfully at the first attempt (p = 0.5). In 45% of cases in the SONO group, bi-prong forceps were used as salvage for short-advancement. In one case in the X-ray group over-advancement occurred. One month after surgery, the stone-free rate on the CT-scan was 75% for the X-ray group and 85% for the SONO group (p = 0.4). There were no significant differences in operation time, hospitalization duration, transfusion, or complication rates between the two groups. We conclude that ultrasound-guided renal puncture, followed by endoscopically guided tract dilatation can achieve a high success rate similar to X-ray-guided PCNL while avoiding the harmful effects of radiation exposure and the risk of over-advancement.


Assuntos
Dilatação , Cálculos Renais , Nefrolitotomia Percutânea , Punções , Ultrassonografia de Intervenção , Humanos , Fluoroscopia/métodos , Cálculos Renais/cirurgia , Cálculos Renais/diagnóstico por imagem , Nefrolitotomia Percutânea/métodos , Nefrolitotomia Percutânea/efeitos adversos , Nefrolitotomia Percutânea/instrumentação , Masculino , Feminino , Pessoa de Meia-Idade , Punções/métodos , Dilatação/métodos , Dilatação/instrumentação , Adulto , Rim/cirurgia , Rim/diagnóstico por imagem , Resultado do Tratamento , Idoso
5.
BMC Pediatr ; 24(1): 348, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38769486

RESUMO

BACKGROUND: Acute complete gastric volvulus is a rare and life-threatening disease, which is prone to gastric wall ischemia, perforation, and necrosis. If it is not treated by surgery in time, the mortality rate can range from 30 to 50%. Clinical presentations of acute gastric volvulus are atypical and often mimic other abdominal conditions such as gastritis, gastroesophageal reflux, gastric dilation, and pancreatitis. Imaging studies are crucial for diagnosis, with barium meal fluoroscopy being the primary modality for diagnosing gastric volvulus. Cases of acute gastric volvulus diagnosed by ultrasound are rarely reported. CASE PRESENTATION: We reported a rare case of acute gastric volvulus in a 4-year-old Chinese girl who presented with vomiting and abdominal pain. Ultrasound examination revealed the "whirlpool sign" in the cardia region, raising suspicion of gastric volvulus. Diagnosis was confirmed by X-ray barium meal fluoroscopy, which indicated left-sided diaphragmatic hernia and obstruction at the cardia region. Surgical intervention confirmed our suspicion of acute complete gastric volvulus combined with diaphragmatic hernia. CONCLUSION: In this case, we reported an instance of acute complete gastric volvulus. Ultrasound revealed a "whirlpool sign" in the cardia, which is likely to be a key sign for the diagnosis of complete gastric volvulus.


Assuntos
Hérnias Diafragmáticas Congênitas , Volvo Gástrico , Humanos , Volvo Gástrico/complicações , Volvo Gástrico/diagnóstico por imagem , Volvo Gástrico/cirurgia , Volvo Gástrico/diagnóstico , Feminino , Pré-Escolar , Doença Aguda , Hérnias Diafragmáticas Congênitas/complicações , Hérnias Diafragmáticas Congênitas/diagnóstico por imagem , Hérnias Diafragmáticas Congênitas/cirurgia , Ultrassonografia , Fluoroscopia
6.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(2): 179-183, 2024 Mar 30.
Artigo em Chinês | MEDLINE | ID: mdl-38605618

RESUMO

Objective: To introduce a locating device for the entry point of intramedullary nail based on the inertial navigation technology, which utilizes multi-dimensional angle information to assist in rapid and accurate positioning of the ideal direction of femoral anterograde intramedullary nails' entry point, and to verify its clinical value through clinical tests. Methods: After matching the locating module with the developing board, which are the two components of the locating device, they were placed on the skin surface of the proximal femur of the affected side. Anteroposterior fluoroscopy was performed. The developing angle corresponding to the ideal direction of entry point was selected based on the X-ray image, and then the yaw angle of the locating module was reset to zero. After resetting, the locating module was combined with the surgical instrument to guide the insertion angle of the guide wire. The ideal direction of entry point was accurately located based on the angle guidance. By setting up an experimental group and a control group for clinical surgical operations, the number of guide wire insertion times, surgical time, fluoroscopy frequency, and intraoperative blood loss with or without the locating device was recorded. Results: Compared to the control group, the experimental group showed significant improvement in the number of guide wire insertion times, surgical time, fluoroscopy frequency, and intraoperative blood loss, with a statistically significant difference (P<0.01). Conclusion: The locating device can assist doctors in quickly locating the entry point of intramedullary nail, effectively reducing the fluoroscopy frequency and surgical time by improving the success rate of the guide wire insertion with one shot, improving surgical efficiency, and possessing certain clinical value.


Assuntos
Fixação Intramedular de Fraturas , Cirurgia Assistida por Computador , Humanos , Pinos Ortopédicos , Perda Sanguínea Cirúrgica , Fluoroscopia/métodos , Fixação Intramedular de Fraturas/métodos , Cirurgia Assistida por Computador/métodos
7.
Ugeskr Laeger ; 186(14)2024 Apr 01.
Artigo em Dinamarquês | MEDLINE | ID: mdl-38606703

RESUMO

Bronchoscopy has a low risk of complications when diagnosing peripheral lung lesions suspected of malignancy, however the procedures do not always determine a diagnosis. Several modalities have been invented to improve the diagnostic yield, including radial endobronchial ultrasound and electromagnetic navigation, which are currently used by several departments in Denmark. Augmented fluoroscopy, CT-guided bronchoscopy and robotic bronchoscopy are not yet available in Denmark, but may improve the diagnostic work-up, as argued in this review.


Assuntos
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico , Broncoscopia/métodos , Fluoroscopia/métodos , Endossonografia/métodos , Pulmão/patologia
8.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 80(5): 519-529, 2024 May 20.
Artigo em Japonês | MEDLINE | ID: mdl-38569842

RESUMO

The goal of our study was to clarify the effect of low pulse rate fluoroscopy applying in percutaneous coronary intervention (PCI) on devices' visibility and radiation dose. Four types of fluoroscopy conditions combined with two pulse rates (7.5 and 15 pulses/s) and two types of adaptive temporal filters (ATFs) (weak and strong) were used. Samples for visibility evaluation were acquired with moving phantom and devices such as stent, balloon, and guidewire. Trailing artifacts and the visibility of stent were evaluated by Scheffe's method of paired comparisons. Incident air kerma (Ka,r) and kerma area product (PKA) in the clinic were obtained under two fluoroscopic pulse rate conditions (7.5 and 15 pulses/s). As a result, in 7.5 pulses/s fluoroscopy, trailing artifacts were decreased by using weak ATF with the median value of PKA and Ka,r reduced by about 50%, but stent visibility was decreased compared to 15 pulses/s. Therefore, a combination of 7.5 pulses/s fluoroscopy and suitable ATF can bring dose reduction with avoiding trailing artifacts, but dose per pulse should be adjusted to maintain the stent visibility.


Assuntos
Intervenção Coronária Percutânea , Doses de Radiação , Fluoroscopia , Humanos , Imagens de Fantasmas , Stents , Artefatos
9.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 398-404, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632057

RESUMO

Objective: To explore the effectiveness of irreducible intertrochanteric femoral fracture in the elderly by treating with folding top technique and right-angle pliers prying and pulling under G-arm X-ray fluoroscopy. Methods: The clinical data of 74 elderly patients with irreducible intertrochanteric femoral fracture admitted between February 2016 and December 2022 and met the selection criteria were retrospectively analyzed. Among them, 38 cases were treated with folding top technique combined with right-angle pliers prying and pulling under G-arm X-ray fluoroscopy and intramedullary nailing fixation (study group), and 36 cases were treated with limited open reduction combined with other reduction methods and intramedullary nailing fixation (control group). There was no significant difference in baseline data between the two groups, such as age, gender, cause of injury, affected side and classification of fractures, complicated medical diseases, and time from injury to operation ( P>0.05). The operation time, intraoperative blood loss, hospital stay, fracture reduction time, fracture healing time, and complications of the two groups were recorded and compared. The quality of fracture reduction was evaluated by Baumgaertner et al. and Chang et al. fracture reduction standards. Results: Patients in both groups were followed up 10-14 months, with an average of 12 months. The operation time and intraoperative blood loss in the study group were significantly less than those in the control group ( P<0.05), there was no significant difference in hospital stay between the two groups ( P>0.05). At 2 days after operation, according to the fracture reduction standards of Baumgaertner et al. and CHANG Shimin et al., the quality of fracture reduction in the study group was better than that in the control group, and the fracture reduction time in the study group was shorter than that in the control group, with significant differences ( P<0.05). After operation, the fractures of the two groups all healed, and there was no significant difference in healing time between the two groups ( P>0.05). During the follow-up, there was no complication such as incision infection, internal fixation failure, deep venous thrombosis of lower limbs, intramedullary nail breakage, spiral blade cutting, or hip varus in the two groups, except for 2 cases of coxa vara in the control group. Conclusion: For the irreducible intertrochanteric femoral fracture, using folding top technique combined with right-angle pliers prying and pulling under G-arm X-ray fluoroscopy can obviously shorten the operation time, reduce the intraoperative blood loss, and improve the quality of fracture reduction.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Humanos , Idoso , Perda Sanguínea Cirúrgica , Estudos Retrospectivos , Raios X , Resultado do Tratamento , Pinos Ortopédicos , Fraturas do Quadril/cirurgia , Fluoroscopia , Consolidação da Fratura
11.
Sci Rep ; 14(1): 9272, 2024 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653756

RESUMO

The transpedicular procedure has been widely used in spinal surgery. The determination of the best entry point is the key to perform a successful transpedicular procedure. Various techniques have been used to determine this point, but the results are variable. This study was carried out to determine the posterior endpoint of the lumbar pedicle central axis on the standard anterior-posterior (AP) fluoroscopic images. Computer-aided design technology was used to determine the pedicle central axis and the posterior endpoint of the pedicle central axis on the posterior aspect of the vertebra. The standard AP fluoroscopic image of the lumbar vertebral models by three-dimensional printing was achieved. The endpoint projection on the AP fluoroscopic image was determined in reference to the pedicle cortex projection by the measurements of the angle and distance on the established X-Y coordinate system of the radiologic image. The projection of posterior endpoint of the lumbar pedicle central axis were found to be superior to the X-axis of the established X-Y coordinate system and was located on the pedicle cortex projection on the standard AP fluoroscopic image of the vertebra. The projection point was distributed in different sectors in the coordinate system. It was located superior to the X-axis by 18° to 26° at L1, while they were located superior to the X-axis by 12° to 14° at L2 to L5. The projections of posterior endpoints of the lumbar pedicle central axis were located in different positions on the standard AP fluoroscopic image of the vertebra. The determination method of the projection point was helpful for selecting an entry point for a transpedicular procedure with a fluoroscopic technique.


Assuntos
Vértebras Lombares , Parafusos Pediculares , Vértebras Lombares/cirurgia , Vértebras Lombares/diagnóstico por imagem , Fluoroscopia/métodos , Humanos , Masculino , Feminino , Fusão Vertebral/métodos , Impressão Tridimensional , Desenho Assistido por Computador
12.
Sci Rep ; 14(1): 9475, 2024 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658572

RESUMO

The Periacetabular Osteotomy is a technically demanding procedure that requires precise intraoperative evaluation of pelvic anatomy. Fluoroscopic images pose a radiation risk to operating room staff, scrubbed personnel, and the patient. Most commonly, a Standard Fluoroscope with an Image Intensifier is used. Our institution recently implemented the novel Fluoroscope with a Flat Panel Detector. The purpose of this study was to compare radiation dosage and accuracy between the two fluoroscopes. A retrospective review of a consecutive series of patients who underwent Periacetabular Osteotomy for symptomatic hip dysplasia was completed. The total radiation exposure dose (mGy) was recorded and compared for each case from the standard fluoroscope (n = 27) and the flat panel detector (n = 26) cohorts. Lateral center edge angle was measured and compared intraoperatively and at the six-week postoperative visit. A total of 53 patients (96% female) with a mean age and BMI of 17.84 (± 6.84) years and 22.66 (± 4.49) kg/m2 (standard fluoroscope) and 18.23 (± 4.21) years and 21.99 (± 4.00) kg/m2 (flat panel detector) were included. The standard fluoroscope averaged total radiation exposure to be 410.61(± 193.02) mGy, while the flat panel detector averaged 91.12 (± 49.64) mGy (p < 0.0001). The average difference (bias) between intraoperative and 6-week postoperative lateral center edge angle measurement was 0.36° (limits of agreement: - 3.19 to 2.47°) for the standard fluoroscope and 0.27° (limits of agreement: - 2.05 to 2.59°) for the flat panel detector cohort. Use of fluoroscopy with flat panel detector technology decreased the total radiation dose exposure intraoperatively and produced an equivalent assessment of intraoperative lateral center edge angle. Decreasing radiation exposure to young patients is imperative to reduce the risk of future comorbidities.


Assuntos
Osteotomia , Doses de Radiação , Exposição à Radiação , Humanos , Fluoroscopia/métodos , Feminino , Masculino , Exposição à Radiação/prevenção & controle , Estudos Retrospectivos , Osteotomia/instrumentação , Osteotomia/métodos , Adolescente , Adulto Jovem , Acetábulo/cirurgia , Acetábulo/diagnóstico por imagem , Adulto , Luxação do Quadril/prevenção & controle , Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/etiologia , Criança
13.
Sci Rep ; 14(1): 9406, 2024 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658695

RESUMO

This retrospective study evaluated the safety and efficacy of fluoroscopy-guided urethral catheterization in patients who failed blind or cystoscopy-assisted urethral catheterization. We utilized our institutional database between January 2011 and March 2023, and patients with failed blind or cystoscopy-assisted urethral catheterization and subsequent fluoroscopy-guided urethral catheterization were included. A 5-Fr catheter was inserted into the urethral orifice, and the retrograde urethrography (RGU) was acquired. Subsequently, the operator attempted to pass a hydrophilic guidewire to the urethra. If the guidewire and guiding catheter could be successfully passed into the bladder, but the urethral catheter failed pass due to urethral stricture, the operator determined either attempted again with a reduced catheter diameter or performed balloon dilation according to their preference. Finally, an appropriately sized urethral catheter was selected, and an endhole was created using an 18-gauge needle. The catheter was then inserted over the wire to position the tip in the bladder lumen and ballooned to secure it. We reviewed patients' medical histories, the presence of hematuria, and RGU to determine urethral abnormalities. Procedure-related data were assessed. Study enrolled a total of 179 fluoroscopy-guided urethral catheterizations from 149 patients (all males; mean age, 73.3 ± 13.3 years). A total of 225 urethral strictures were confirmed in 141 patients, while eight patients had no strictures. Urethral rupture was confirmed in 62 patients, and hematuria occurred in 34 patients after blind or cystoscopy-assisted urethral catheterization failed. Technical and clinical success rates were 100%, and procedure-related complications were observed in four patients (2.2%). The mean time from request to urethral catheter insertion was 129.7 ± 127.8 min. The mean total fluoroscopy time was 3.5 ± 2.5 min and the mean total DAP was 25.4 ± 25.1 Gy cm2. Balloon dilation was performed in 77 patients. Total procedure time was 9.2 ± 7.6 min, and the mean procedure time without balloon dilation was 7.1 ± 5.7 min. Fluoroscopy-guided urethral catheterization is a safe and efficient alternative in patients where blind or cystoscopy-assisted urethral catheterization has failed or when cystoscopy-urethral catheterization cannot be performed.


Assuntos
Cistoscopia , Estreitamento Uretral , Cateterismo Urinário , Humanos , Fluoroscopia/métodos , Cistoscopia/métodos , Cistoscopia/efeitos adversos , Masculino , Idoso , Estudos Retrospectivos , Pessoa de Meia-Idade , Estreitamento Uretral/terapia , Estreitamento Uretral/diagnóstico por imagem , Cateterismo Urinário/métodos , Cateterismo Urinário/efeitos adversos , Idoso de 80 Anos ou mais , Uretra/diagnóstico por imagem , Uretra/cirurgia
14.
Neurol Res ; 46(5): 426-436, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38557428

RESUMO

OBJECTIVE: Pedicle screw stabilization (PSS) surgeries for spinal instability are still the most effective treatment approach. The use of preoperative planning can minimize the complications related to transpedicular screw (TPS) misplacement. The study aimed to evaluate the surgical outcomes of a guide device developed to improve the accuracy of the free-hand technique using three-dimensional planning in PSS. PATIENTS AND METHODS: Patients with degenerative spinal diseases who underwent open PSS between 2019 and 2022 were evaluated retrospectively. FG group included patients who were operated on using the fluoroscopy alone with preoperative two-dimensional planning. AFG group included patients who were operated on using a guide advice-assisted technique with preoperative 3DP. Between-group comparisons were performed. RESULTS: A total of 143 patients with a mean age of 59.6 years were included in the study. 71 patients were assessed in the FG group and 72 patients in the AFG group. Between-group comparisons regarding demographics, etiologies, radiation exposure, and functional improvements showed no significant differences (p > 0.05). Although the accuracy of TPSs positioning was 94.2% and 96.5% in the 2DG and 3DG, the difference between the groups was not statistically significant. The statistically significant differences regarding the upper-level facet joint violation and pedicle breach rates were lower in the AFG group (p < 0.0001; X2 = 19.57) and (p < 0.0001; X2 = 25.3), respectively. CONCLUSION: Using a guide device associated with preoperative 3PD reduced the upper-level facet joint violation and pedicle breach rates in open PSS surgeries performed by free-hand technique for degenerative spinal diseases.


Assuntos
Vértebras Lombares , Parafusos Pediculares , Humanos , Pessoa de Meia-Idade , Masculino , Feminino , Estudos Retrospectivos , Vértebras Lombares/cirurgia , Vértebras Lombares/diagnóstico por imagem , Idoso , Imageamento Tridimensional/métodos , Cuidados Pré-Operatórios/métodos , Cuidados Pré-Operatórios/instrumentação , Adulto , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação , Resultado do Tratamento , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/instrumentação , Fluoroscopia/métodos
15.
J Radiol Prot ; 44(2)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38636477

RESUMO

National Council on Radiation Protection and Measurements Commentary No. 33 'Recommendations for Stratification of Equipment Use and Radiation Safety Training for Fluoroscopy' defines an evidence-based, radiation risk classification for fluoroscopically guided procedures (FGPs), provides radiation-related recommendations for the types of fluoroscopes suitable for each class of procedure, and indicates the extent and content of training that ought to be provided to different categories of facility staff who might enter a room where fluoroscopy is or may be performed. For FGP, radiation risk is defined by the type and likelihood of radiation hazards that could be incurred by a patient undergoing a FGP. The Commentary also defines six training groups of facility staff based on their role in the fluoroscopy room. The training groups are based on a combination of job descriptions and the procedures in which these individuals might be involved. The Commentary recommends the extent and content of training that should be provided to each of these training groups. It also provides recommendations on training formats, training frequency, and methods for demonstrating that the learner has acquired the necessary knowledge.


Assuntos
Proteção Radiológica , Fluoroscopia , Humanos , Exposição Ocupacional/prevenção & controle , Lesões por Radiação/prevenção & controle
16.
Radiat Prot Dosimetry ; 200(7): 693-699, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38679858

RESUMO

This study presented a model applied for potential risk assessment in an interventional radiology setting. The model of potential risk assessment (MARP) consisted of the creation of a scale of indicators ranging from 0 to 5. The radiation levels were categorized according to gender, kind of procedure, value of kerma air product (Pka), and accumulated radiation dose (mGy). The MARP model was applied in 121 institutions over 8 y. A total of 201 656 patient radiation doses (Dose-area product and accumulated kerma) data were launched into the system over time, with an average of 22 406 doses per year. In the context of the workers (cardiologists, radiographers, and nurses) monitored during the MARP application, 8007 cases (with an average of 890 per year) of occupational radiation doses were recorded. This study showed a strategy for quality evaluation in fluoroscopy using a model with a compulsory information system for monitoring safety.


Assuntos
Exposição Ocupacional , Doses de Radiação , Humanos , Fluoroscopia/métodos , Medição de Risco/métodos , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Feminino , Masculino , Radiografia Intervencionista/efeitos adversos , Monitoramento de Radiação/métodos , Proteção Radiológica/normas , Proteção Radiológica/métodos , Radiologia Intervencionista/métodos , Radiologia Intervencionista/normas , Exposição à Radiação/análise
17.
Eur Arch Otorhinolaryngol ; 281(6): 3095-3105, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38581573

RESUMO

PURPOSE: Dysphagia is a prevalent symptom observed in acute stroke. Several bedside screening tests are employed for the early detection of dysphagia. Pulse oximetry emerges as a practical and supportive method to augment the existing techniques utilized during bedside swallowing assessments. Desaturation levels, as measured by pulse oximetry, are acknowledged as indicative of aspiration by certain screening tests. However, the predictive capability of pulse oximetry in determining aspiration remains a subject of controversy. The objective of this study was to compare aspiration and oxygen desaturation levels by time and aspiration severity in dysphagic patients compared to healthy controls. It also aimed to evaluate the accuracy of pulse oximetry by comparing it with VFSS findings in detecting aspiration in both liquid (IDDSI-0) and semi-solid (IDDSI-4) consistencies. MATERIALS AND METHODS: Eighty subjects (40 healthy and 40 acute stroke patients) participated. Patients suspected of dysphagia underwent videofluoroscopy as part of the stroke unit's routine procedure. Baseline SpO2 was measured before VFSS, and stabilized values were recorded. Sequential IDDSI-0 and IDDSI-4 barium tests were conducted with 5 ml boluses. Stabilized SPO2 values were recorded during swallowing and 3-min post-feeding. Patients with non-dysphagia received equal bolus monitoring. Changes in SPO2 during, before, and after swallowing were analyzed for each consistency in both groups. RESULTS: The study revealed a statistically significant difference in SPO2 between patients with dysphagia and controls for IDDSI-4 and IDSSI-0. In IDDSI-4, 20% of patients experienced SpO2 decrease compared to 2.5% in control group (p = 0.013). For IDDSI-0, 35% of patients showed SpO2 decrease, while none in the control group did (p = 0.0001). Aspiration rates were 2.5% in IDDSI-4 and 57.5% in IDDSI-0. In IDDSI-0, SpO2 decrease significantly correlated with aspiration (p = 0.0001). In IDDSI-4, 20.5% had SpO2 decrease without aspiration, and showing no significant difference (p = 0.613). Penetration-Aspiration Scale scores had no significant association with SpO2 decrease (p = 0.602). Pulse oximetry in IDDSI-4 had limited sensitivity (0%) and positive predictive value, (0%) while in IDDSI-0, it demonstrated acceptable sensitivity (60.9%) and specificity (100%) with good discrimination capability (AUC = 0.83). CONCLUSIONS: A decrease in SPO2 may indicate potential aspiration but is insufficient alone for detection. This study proposes pulse oximetry as a valuable complementary tool in assessing dysphagia but emphasizes that aspiration cannot be reliably predicted based solely on SpO2 decrease.


Assuntos
Transtornos de Deglutição , Oximetria , Acidente Vascular Cerebral , Humanos , Transtornos de Deglutição/etiologia , Transtornos de Deglutição/diagnóstico , Oximetria/métodos , Masculino , Feminino , Fluoroscopia/métodos , Acidente Vascular Cerebral/complicações , Pessoa de Meia-Idade , Idoso , Gravação em Vídeo , Estudos de Casos e Controles , Aspiração Respiratória/etiologia , Aspiração Respiratória/diagnóstico , Adulto
18.
Abdom Radiol (NY) ; 49(5): 1646-1652, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38592493

RESUMO

PURPOSE: To evaluate the efficacy and safety of a novel technique for removal of migrated esophageal stent (MES) under fluoroscopy. METHODS: From January 2009 to April 2023, 793 patients with a dysphagia score of 3-4 underwent esophageal stenting at our center, and 25 patients (mean age: 70.06 years old; male/female: 15/10) underwent stent removal using "loop method" under fluoroscopy. The primary outcomes were technical success and complications. The secondary outcomes were procedure time, radiation exposure, biochemical indicators [white blood cell (WBC), hemoglobin (Hb), platelet (PLT), albumin (ALB), alanine transaminase (ALT), total bilirubin (TB), urea nitrogen (UN) and C-reactive protein] of pre- and post-treatment at 2 weeks. RESULTS: Technical success was 100% without major complications. The mean procedure time was (39.44 ± 9.28) minutes, which showed no statistical significance between benign (n = 5) and malignant (n = 20) group [(42.40 ± 8.85) vs (38.71 ± 9.46) mins, p > 0.05]. The mean radiation exposure was (332.88 ± 261.47) mGy, which showed no statistical significance between benign and malignant group [(360.74 ± 231.43) vs (325.92 ± 273.54) mGy, p > 0.05]. Pre- and post-procedure Hb [(114.46 ± 11.96) vs. (117.57 ± 13.12) g/L] and ALB [(42.26 ± 3.39) vs. (44.12 ± 3.77) g/L] showed significant difference (p < 0.05), while WBC, PLT, CRP, and ALT showed no significance (p > 0.05). CONCLUSION: Fluoroscopy-guided "Loop method" for MES removal is an effective and safe alternative technique.


Assuntos
Remoção de Dispositivo , Stents , Humanos , Feminino , Fluoroscopia , Masculino , Idoso , Remoção de Dispositivo/métodos , Migração de Corpo Estranho/diagnóstico por imagem , Estudos Retrospectivos , Pessoa de Meia-Idade , Transtornos de Deglutição/etiologia , Radiografia Intervencionista/métodos , Idoso de 80 Anos ou mais
19.
J Orthop Surg (Hong Kong) ; 32(1): 10225536241243166, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38546214

RESUMO

Background: Over the last few decades, shoulder surgery has undergone rapid advancements, with ongoing exploration and the development of innovative technological approaches. In the coming years, technologies such as robot-assisted surgeries, virtual reality, artificial intelligence, patient-specific instrumentation, and different innovative perioperative and preoperative planning tools will continue to fuel a revolution in the medical field, thereby pushing it toward new frontiers and unprecedented advancements. In relation to this, shoulder surgery will experience significant breakthroughs. Main body: Recent advancements and technological innovations in the field were comprehensively analyzed. We aimed to provide a detailed overview of the current landscape, emphasizing the roles of technologies. Computer-assisted surgery utilizing robotic- or image-guided technologies is widely adopted in various orthopedic specialties. The most advanced components of computer-assisted surgery are navigation and robotic systems, with functions and applications that are continuously expanding. Surgical navigation requires a visual system that presents real-time positional data on surgical instruments or implants in relation to the target bone, displayed on a computer monitor. There are three primary categories of surgical planning that utilize navigation systems. The initial category involves volumetric images, such as ultrasound echogram, computed tomography, and magnetic resonance images. The second type is based on intraoperative fluoroscopic images, and the third type incorporates kinetic information about joints or morphometric data about the target bones acquired intraoperatively. Conclusion: The rapid integration of artificial intelligence and deep learning into the medical domain has a significant and transformative influence. Numerous studies utilizing deep learning-based diagnostics in orthopedics have remarkable achievements and performance.


Assuntos
Robótica , Cirurgia Assistida por Computador , Humanos , Inteligência Artificial , Ombro , Fluoroscopia
20.
Phys Med ; 120: 103324, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38458105

RESUMO

PURPOSE: During any radiological procedure, it is important to know the dose to be-administered to the patient and this can be done by estimating the output of the X-ray tube either with a dosimeter or with a mathematical equation or Monte Carlo simulations. The aim of this work is to develop a new mathematical model equation (NMME) for estimating the output of high-frequency X-ray tubes. METHODS: To achieve this, data collected from ten machines in many regions of Cameroon were used (for nine machines) to build an initial model that does not take into account the anode angle and the tenth machine was used to test the model. Using the SpekCalc software, some simulations were carried out to evaluate the influence of the anode angle. This allowed the NMME to be proposed. RESULTS: The deviations frequencies between 0.65% and 19.61% were obtained by comparing the output values obtained using initial model with the measured values. The statistical hypothesis test showed that the estimated values using initial model and NMME are in agreement with those measured unlike the Kothan and Tungjai model. For the tenth machine, the percentage difference between estimated and measured values is less than 8 %. CONCLUSION: These results show that the proposed model performed better than the previous models. In the absence of a dosimeter, the NMME could be used to estimate the output of high frequency X-ray machines and therefore the radiation doses received by patients during diagnostic X-ray examinations.


Assuntos
Modelos Teóricos , Software , Humanos , Raios X , Fluoroscopia , Radiografia , Método de Monte Carlo , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA